Home
ComfortSelect User Manual
Contents
1. at the bottom of the cushion catch on and fit securely into the two tabs at the bottom of the faceplate 3 Place the retaining ring around the cushion 4 Connect the ring clips to the faceplate starting with the top clip Push the retaining ring into the faceplate until you hear a clicking sound Note Make sure the lines on the bottom of the faceplate cushion and retaining ring are all aligned when assembled Forehead Pad Replacement If you need to replace the forehead pad contact your home care provider to reorder Follow the instructions below Figure 6 1 Remove the pad Slide the pad outward toward one edge of the forehead support and lift it upward so the connection track on that side is released from the plastic connection slot Next pull the pad in the opposite direction to release the connection track on the other side from its connection slot 2 Install the new pad Slide one of the connection tracks on the new pad into its connection slot on the support Pull the pad A Connection Point for Clip in the opposite direction toward the center and slide the B Faceplate connection track into its connection slot to lock the pad into C Cushion place D Retaining Ring E Clip 6 Note Replace the cushion and forehead pad if damaged deformed or hardened Q Comfort Tips Clean your face and mask thoroughly before each use e Make sure the mask is
2. 010 Koninklijke Philips Electronics N V All rights reserved
3. PHILIPS SS RESPIRONICS Instructions for Use ComfortSelect Nasal Mask and Premium Headgear Intended Use The ComfortSelect Nasal Mask is intended to provide an interface for application of CPAP or bi level therapy to patients The mask is for single patient use in the home or multi patient use in the hospital institutional environment The mask is to be used on patients gt 66lbs 30kg for whom CPAP or bi level therapy has been prescribed S Important Note An exhalation port is built into the ComfortSelect Nasal Mask so a separate exhalation port is not required Caution U S federal law restricts this device to sale by or on the order of a physician Symbols Warning or Consult instructions AE Note Tip for use Does not contain System One Resistance natural rubber latex ontrol Setting A Warnings e This mask is not suitable for providing life support ventilation This mask is designed for use with CPAP or bi level systems recommended by your health care professional or respiratory therapist Do not wear this mask unless the CPAP or bi level system is turned on and operating properly Do not block or try to seal the exhalation port Explanation of the Warning CPAP systems are intended to be used with special masks with connectors which have vent holes to allow continuous flow of air out of the mask When the CPAP machine is turned on and functioning properly new air from the CPAP machine flushes the exha
4. led air out through the attached mask exhalation port However when the CPAP machine is not operating enough fresh air will not be provided through the mask and exhaled air may be rebreathed This warning applies to most models of CPAP systems Rebreathing of exhaled air for longer than several minutes can in some circumstances lead to suffocation e If oxygen is used with the device the oxygen flow must be turned off when the device is not operating Explanation of the Warning When the device is not in operation and the oxygen flow is left on oxygen delivered into the ventilator tubing may accumulate within the device enclosure Oxygen accumulated in the device enclosure will create a risk of fire Oxygen supports combustion Oxygen should not be used while smoking or in the presence of an open flame Ata fixed flow rate of supplemental oxygen flow the inhaled oxygen concentration will vary depending on the pressure settings patient breathing pattern mask selection and the leak rate This warning applies to most types of CPAP and bi level machines Some users may experience skin redness irritation or discomfort If this happens discontinue use and contact your healthcare professional At low CPAP or EPAP pressures the flow through the exhalation port may be inadequate to clear all exhaled gas from the tubing Some rebreathing may occur Hand wash prior to first use Inspect the mask for damage or wear cracking crazing tea
5. on Port the mask between patients These instructions can be obtained by Do not block visiting www sleepapnea com or contacting Customer Service at D Swivel l 1 800 345 6443 USA or Canada or 1 724 387 4000 E Swivel Clip System One Resistance Control L This mask uses the System One Resistance Control setting rs X1 This symbol may appear on your therapy device This symbol represents the level of mask resistance compensation Match the setting to the mask if appropriate 6 Important Notes e Verify the System One setting if the mask or mask cushion changes e The System One setting is not compatible with masks requiring a separate additional exhalation device If your provider has locked the resistance compensation setting you can view the setting but cannot change it and the screen will display a lock symbol If your provider has disabled the resistance compensation you will not see this setting Achieving the Right Fit 1 Hold the mask cushion gently over your nose If the forehead support does not rest comfortably against your forehead press the ridged sides at the bottom of the support arm and slide the arm up or down the bar until the arm is in a position that is comfortable for you 2 Slide the headgear over your head You may want to disconnect one of the swivel clips before putting on the headgear Reconnect the swivel clip after you have the headgear in position 3 Connect the flexible tubing included with
6. rs etc Discard and replace any components as necessary Use of a nasal or full face mask may cause tooth gum or jaw soreness or aggravate an existing dental condition Consult your physician or dentist if symptoms occur e If an additional exhalation device is added to the patient circuit you may need to adjust the pressure level to compensate for the additional leak of the exhalation device Cleaning Instructions Hand wash the mask before first use and daily The headgear should be hand washed weekly or as needed The headgear does not need to be removed for daily cleaning of the mask 1 Hand wash the mask and headgear in warm water with a mild liquid dish washing detergent Figure 2 A Caution Do not use bleach alcohol cleaning solutions containing bleach or alcohol or cleaning solutions containing conditioners or moisturizers 2 Rinse thoroughly with drinking quality water and air dry out of direct sunlight Make sure the mask is dry before use Lay the headgear flat or line dry Do not place the headgear into the dryer 3 Inspect all parts for damage or wear replace any parts that have visibly deteriorated cracking crazing tears etc Replace Figure 1 the mask if the cushion becomes hardened A Forehead Support For multi patient use in the hospital institutional environment B Forehead Support Arm use the Mask Cleaning and Disinfection Instructions to reprocess C Exhalati
7. the correct size for your face Do not overtighten the headgear Overtightening can irritate your face increase leaks or cause damage to the mask Replace the cushion and forehead pad if they become hardened or deformed Disposal Dispose of in accordance with local regulations Specifications A Warning The technical specifications of the mask are provided for your healthcare professional to determine if it is compatible with your CPAP or bi level therapy device If used outside these specifications or if used with incompatible devices the mask may be uncomfortable the seal of the mask may not be effective optimum therapy may not be achieved and leak or variation in the rate of leak may affect device function Intentional Leak Pressure Drop cm H 0 hPa 50 SLPM 100 SLPM g All cushion 0 1 0 2 a sizes S M SW 3 Deadspace ae S 119 cc X 7 ne Mi129 cc SW 128 cc Pressure cm H 0 hPa Storage Conditions Temperature 4 F to 140 F 20 C to 60 C Relative Humidity 15 to 95 non condensing Reorder Numbers 007919 ComfortSelect Mask w hgr M 002720 Split Washer Kit 5 each 007931 ComfortSe ask w hgr 7041 ask Swivel Small Wide 007936 ComfortSelect hion S 312710 O2 Enrichment Attachment 007935 ComfortSe hion 007937 ComfortSe hion Small Wide Respironics Inc 1001 Murry Ridge Lane Murrysville PA 15668 USA 1067720 taal JDH 3 29 10 2
8. your CPAP or bi evel device to the swivel on the mask Figure 2 4 Turn on the airflow 5 Lie down and breathe normally through your nose keeping your lips closed You may need to adjust the forehead support 4 Figure 2 arm to reduce leaks or reduce pressure points at the bridge or above the lip A Exhalation device 6 Loosen the EZPeel tabs to unhook the straps and gradually B Do not block tighten them until the mask has minimal leaks and fits B o with eel tabs fortably DO C Flexible tubing to device Removing the Mask and Headgear You can disconnect the headgear from the mask in the following ways 1 Disconnect the forehead support by pressing on the center of the forehead support and then gently pressing the sides of the forehead support arm together Figure 3 2 Disconnect the neck straps by removing the swivel clips from their sockets Figure 4 3 Slide the headgear over your head The entire headgear stretches Figure 5 LS aN Figure 3 Figure 4 4 Figure 5 Cushion Removal and Reattachment 1 Remove the cushion by detaching its retaining ring from the faceplate Do this by unhooking the side and bottom clips of the ring from their connection points on the faceplate Take the ring off of the cushion Clean or discard the cushion if necessary 2 Place the cleaned or new cushion on the faceplate making sure that the two slits
Download Pdf Manuals
Related Search
Related Contents
istruzioni di montaggio e manutenzione instructions pour le dreamGEAR DGDXL-2697 game console accessory Kabayaki for Windows 取扱説明書 Version 1.5.1 Samsung B3410 Uživatelská přiručka OnlinePlantCenter L832CL Use and Care Manual Black & Decker Fire Storm 5146961-02 Instruction Manual 光訪問サポート提供条件 (PDF形式:67KB) go•pod™ NucleoSpin® 96 Trace - MACHEREY Copyright © All rights reserved.