Home

Specification

image

Contents

1. i Stand by dimming level W means dimming down ora o o The button Test 2s is for testing purpose only The sensor goes to test mode hold time is 2s automatically after commissoning meanwhile the stand by period and daylight sensor are disabled HRC 05 This mode can be ended by pressing reset or any button of scene mode and hold Note The buzzer beeps one time The sensor setting is changed accordingly time when RC receives signal successfully P P Power output By pressing these two buttons the output shifts between 80 at initial 10 000 hours and 100 for energy saving purpose Lux disa ble Press this button the built in daylight sensor stops working and all motion detected could turn on the lighting fixture no matter how bright the natural light is Ambient daylight threshold Press this button the latest surrounding lux value overwrites previous lux value learned and is set as the daylight threshold This feature enables the fixture to function well in any real application circumstance Scene mode There are 4 scene modes fixed program built in the remote control to choose for different applications Detection range Stand by dimming level Note end user can adjust the settings by pressing buttons of detection range hold time stand by period stand by dimming level daylight sensor The lastest setting stays in validity Detection range Press
2. 220 240VAC 50 60Hz O 1520 TAA 32 5W Max 20s 100 750 10 on RC TEST 2s 30s Imin 5min lOmin 30min on RE 2Lux 10OLlux 50Lux Lux disable on RC Os 10s Imin lOmin 30min ee on RC 10 20 30 on RC 5 8GHz 75MHz lt O 2mW Max xH 8m x 5m 30 150 Max 5m 350mA 500mA 550mA 700mA 750mA 900mA 10 48V 350mA 10 48V 500mA 10 46V 550mA 10 40V 700mA 10 37V 750mA 10 31V QO00mA 3 5 17W 350mA 5 24W 500mA 5 5 25W 550mA 7 28W 700mA 7 28W 750mA 9 28W 9OO0mA 6OV gt 0 9 85 Max 20 C 50 C FeV oC Output short circuit protection with auto reset EN55015 EN61547 EINGIS4741 EING 34 722 18 Semko CB EMC CE R amp TTE SAA Inputoutput 3750VAC S5mA 1 min IP20
3. 750mA 10 31V QOO0mA Settings Rotary Switch on Sensor Antenna Instead of the DIP swiches end user can easily choose the settings by the rotary switch There are total 16 channels combinations which could meet different requirements in real application Detection range 100 a N The protrusion of the sensor antenna can stick out of the LED panel which enables eN end user to change the sensor setting directly without opening up the fixture The cutout is only 36 x 29 5 mm which eliminates the potential risk of shadow O this QR codes links installer to the user manual on HYTRONIK web to check the details of setting program QR code on the housing for channel settings Cutout size 36 x 29 5 mm Settings Remote Control HRC 05 Pemanent ON OFF function Press the ON OFF button the light goes to permanent on or permanent off mode sensor is disabled Press Auto Mode RESET or Scene mode buttons to quit from this mode Press Auto Mode button the sensor starts to work and all settings remain the same as the HYTRONIK C o dD o Detection range W latest status before the light was switched on off Reset function Press RESET button all settings go back to the value of rotary switch Q O cC Long press Dim or Dim to adjust the light brightness during hold time means dimming up n A EA
4. the buttons of detection range to set detection range at 10 50 100 Hold time Press the buttons of hold time to set hold time at 30s Imin 5min 1Omin 30min Daylight sensor Press the buttons of daylight sensor to set daylight threshold at 2Lux 10Lux 50Lux Stand by penod Comdor Function Press the buttons of stand by period to set stand by period at Os 10s Imin 10min 30min 00 Note Os means on off control 2 means bi level dimming control light never switches off when daylight sensor is disabled Stand by dimming level Press the buttons of stand by dimming level to set the stand by dimming level at 10 20 30 Manual Ovemde Absence Detection Button M A is disabled Wiring Diagram Detection Pattern 0 Ceiling mounted height m Wall mounted height m Ceiling mounted detection pattern m Wall mounted detection pattern m Technical Data Operating voltage Input current Input power Warm time Detection area Hold time Daylight threshold Stand by period Stand by dimming level Microwave frequency Microwave power Detection range Detection angle Mounting height Output LED current Output LED voltage Output LED power Empty load voltage Power factor Efficiency Operating temperature Abnormal protection EMC standard Safety standard Certification Dielectric strength IP rating
5. Integrated SensorDIM LED Driver Daylight Monitoring Version Model HEC 7028 with HRC 05 Daylight sensor LED indication L Blue Infrared remote receiver Cutout size L x D 36 x 29 5mm Installation hole 4 1mm Installation hole Sensor antenna LED screw D x L 3 x 1Omm Model HEC7028 Further 20 saving rs a giu ss soft on _ soft off _ Rotary Switch Daylight initial TM 8 hours Over load Programing Monitoring 10 000 hrs sensorDIM manual on Protection Detection Pattern 0 4 di C x Over heat pik tele Hold time 2 50Lux Ambient daylight Protection iianiaiall Multiple Current 25 30min threshold 2 in 1 and cost effective This is a smart integration of microwave motion sensor and multiple current selection LED driver which gives pre selected constant current to drive the LEDs to work based upon movement detection Designed in the software and thanks to our worldwide patented circuit the builtin daylight sensor is prior to motion sensor so as to achieve utmost energy saving purpose Functions and Options Daylight Monitoring Function Hytronik specially designed this function in software for deep energy saving purpose 1 With sufficient natural light the light won t turn on when motion detected 2 After hold time the light turns off completely if surrounding natural light is sufficient 3 When stand by period is preset at the light will turn off completely when surroun
6. ding natural light is sufficient during stand by period and turn on at dimming level automatically when natural light is below daylight threshold With sufficient natural light the At dusk as the natural light The light switches on at 100 Light dims to stand by level after light does not switch on even drops below threshold value when there is movement the holdtime there is movement detected the sensor turns on the light at detected the dimmed level Settings on this demonstration goes in cycle Hold time lOmin Daylight threshold 50lux during the night Stand by period 00 Stand by dimming 10 level 100 on when movement At dawn light turns off Light does not switch on even detected and dims to10 in completely when natural light when movement detected long absence reaches above daylight during the daytime threshold Tri level Dimming Control Comidor Function Same as Tridonic excel control gear Hytronik builds this function inside HEC7028 to achieve tri level dimming control for some areas that require a light change notice before switch off It offers 3 levels of light 100 gt dimmed light gt off With sufficient natural light With insufficient natural light After hold time the light dims The light switches off the light does not switch on it switches on the light when to stand by level or turns off automatically after the when movement detected person enters th
7. e room completely if surrounding stand by period elapsed natural light is above the daylight threshold Ambient Daylight Threshold Switch the power supply to the sensor two times within 2 seconds the sensor can set the ambient lux level as the new threshold This feature enables the daylight sensor to be commissioned to the environment in which it is installed The latest action controls More details of the operation procedure please refer to user manual 8H Manual on Mode For LED Lamp Rapidly turn off on the power supply three times within 3 seconds the light will be 100 on for 8 hours and then goes to sensor mode automatically after 8 hours Useful when sensor function is not needed in special occasion Note this 8H manual on mode can be cancelled by turning off on the power supply one time within second LED Current Selections 1 900mA 1O 750mA mu O 700mA viel 550mA v O O 500mA vi key OC ey 350mA im 2 fem Current O L_1h The current can be easily configured by choosing the correct combination of the DIP switches see table on the left el LED Maximum Load and Voltage This multiple current LED driver has a wide range of loading capacity 3 5 17W 350mA 5 24W 5O0mA 5 5 25W 550mA Maximum load different currents 7 28W 700mA 7 28W 750mA 9 28W 9O0OmA 10 48V 350mA 10 48V 500mA 10 46V 550mA Maximum voltage ditterent currents 10 40V 700mA 10 37V