Home

PNP400 - Herman Pro AV

image

Contents

1. 4 What if my table is thicker than 3 inches Then the area under the table near the PNP400 must be reduced to 3 inches of thickness 5 Are cables Consider using available for MS8126CA 3ft or connecting a MS8156CA 6ft for VGA PC laptop to the connection PNP400 available 6 Does ALTINEX Anything modified by honor any non ALTINEX personnel warranty on field is not covered by modifications warranty SALTINEX Tel 714 990 2300 Toll Free 1 800 ALTINEX FAX 714 990 3303 E mail solutions altinex com Web www altinex com SIGNAL MANAGEMENT SOLUTIONS DESIGNER SOLUTIONS CABLES AND ACCESSORIES 9 ModelNo Description INPUT OUTPUT LABELS MS8301LB Adhesive label with text COVER CUTOUTS CVR1001 Cover cutouts for PNP or TNP units SECTIONAL PLATES SP2107US amp Canada with 2 slots and 12ft metal conduit Dual AC Power Outlet for United States SP2201UK AC Power Qutlet for United Kingdom Singapore 8 Hong Kong SP2301CE AC Power Qutlet for Continental Europe SP2401AU AC Power Outlet for Australia amp New Zealand SP3102EP Dual Empty Snap in Ports with 1 slot SP3103EP Dual Empty Ortronics CAT 6 Snap in Ports with 1 slot SP3201AV 15 pin HD Female to Male 3 5mm Stereo Female to Male SP3202AV 15 pin HD Female to Female Gender Changer 3 5mm Stereo Fem
2. standard Mechanical Base Width inches 6 600in 167mm Height opened 8 690in 220mm Height Above Table 2 956in 75mm Height Below Table 5 552in 141mm minus table thickness Base Depth inches 4 834in 122mm Finish Black T Operating 10 C 35 C T Maximum 50 C Humidity 90 non condensing Table 1 PNP400 Mechanical SALTINEX SIGNAL MANAGEMENT SOLUTIONS Tel 714 990 2300 Toll Free 1 800 ALTINEX FAX 714 990 3303 E mail solutions altinex com Web www altinex com DESIGNER SOLUTIONS PNP400 DIMENSIONS 4 Diagrams 1A 1B 1C amp 1D TOP VIEW FRONT or BACK VIEW OF PNP400 opened PNP400 7 360 6 030 6 636 Diagram 1A Diagram 1B SIDE VIEW SIDE VIEW opened PNP400 closed PNP400 2 879 5 79 8 i 4 803 Diagram 1C Diagram 1D ALTINEX gt Tel 714 990 2300 Toll Free 1 800 ALTINEX FAX 714 990 3303 E mail solutions altinex com Web www altinex com DESIGNER SOLUTIONS APPLICATION DIAGRAMS 5 Diagram 2 Application OPTIONAL SECTIONAL PLATES INSTALLED PNP400 Laptop Computer Computer Video l Computer Video Audio m Audio see Network Interface Interface Network Telephone Telephone AC Power To Proi AC Power jector Rack Video Audio of a Control Room Video Audio To Projector Rack or a Control Room Note Diagram 2 is
3. DESIGNER SOLUTIONS MANUAL PART NUMBER 400 0109 005 PNP400 POP N PLUG TOWER USER S GUIDE ALTINEX Ea Tel 714 990 2300 Toll Free 1 800 ALTINEX FAX 714 990 3303 E mail solutions altinex com Web www altinex com DESIGNER SOLUTIONS TABLE OF CONTENTS Page PRECAUTIONS SAFETY WARNINGS 3 ABOUT YOUR PNP400 sea skal ak Hawkes 4 TECHNICAL SPECIFICATIONS 4 PNP400 DIMENSIONS si aa 5 APPLICATION DIAGRAMS sess 6 INSTALLATION iiiter Ihre rrt Fat aene 8 OP EA TOWN M A GA 9 FREQUENTLY ASKED QUESTIONS FAQ 10 CABLES AND ACCESSORIES 2 11 TROUBLESHOOTING GUIDE 11 ALTINEX POLICY sara i Ente a i bu ME 11 SALTINEX SiGNAL MANAGEMENT SOLUTIONS Tel 714 990 2300 Toll Free 1 800 ALTINEX FAX 714 990 3303 E mail solutions altinex com Web www altinex com DESIGNER SOLUTIONS PRECAUTIONS SAFETY WARNINGS L Please read this manual carefully before using your PNP400 Interconnect Tabletop Solution Keep this manual handy for future reference These safety instructions are to ensure the long life of your PNP400 and to prevent fire and shock hazard Please read them carefully and heed all warnings 1 1 GENERAL e Unauthorized personnel shall not open the unit since there are high voltage components inside e Qualified ALTINEX service personnel or th
4. ale to Terminal Block SP3204AV 4 pin Mini DIN RCA Female 3 5mm Stereo with 1 slot universal plate for PNP400 TROUBLESHOOTING GUIDE 10 The PNP400 supplied unit was carefully tested and no problems were detected however we would like to offer the following suggestions Please make sure that the highest quality video audio network and telephone cables or connectors are used If there has been damage then do not use the PNP400 unit Immediately contact the ALTINEX Sales Department to have the unit repaired ALTINEX POLICY 11 11 1 LIMITED WARRANTY RETURN POLICY Please see the Altinex website at www altinex com for details on warranty and return policy 11 2 CONTACT INFORMATION ALTINEX INC 592 Apollo street Brea CA 92821 USA TEL 714 990 2300 TOLL FREE 1 800 ALTINEX WEB www altinex com E MAIL solutions altinex com SIGNAL MANAGEMENT SOLUTIONS SALTINEX Tel 714 990 2300 Toll Free 1 800 ALTINEX FAX 714 990 3303 E mail solutions altinex com Web www altinex com
5. e compression rod portion of the spring Carefully compress the new spring while aligning the support bracket mounting holes with those in the base unit Fasten the compression rod using 4 40 hardware Under normal conditions the gas spring will last more than five years Shock Screws In Here Figure 4 Removing the Gas Spring SALTINEX Tel 714 990 2300 Toll Free 1 800 ALTINEX FAX 714 990 3303 E mail solutions altinex com Web www altinex com SiGNAL MANAGEMENT SOLUTIONS DESIGNER SOLUTIONS 7 4 HOW TO INSTALL SECTIONAL PLATES Install sectional plates in the empty slots on each side of the PNP400 until the plates snap into place Secure the plates using the plastic reusable rivets as shown in figure 5 PLASTIC REUSABLE RIVETS SECTIONAL PLATE PLASTIC REUSABLE Ep RIVETS SECTIONAL PLATE PLASTIC REUSABLE RIVETS IA PLASTIC REUSABLE RIVETS Figure 5 Installing Sectional Plates Internal view of PNP400 FREQUENTLY ASKED QUESTIONS FAQ 8 No Question 1 What happens if The unit will not stay the spring open breaks 2 What do do if Replace the gas spring the PNP400 Call ALTINEX for service won t stay open information 3 How much room The unit is 5 5 inches is taken up on deep maximum below the underside of the table to this the table dimension add about 2 5 inches for cable clearance
6. eir authorized representatives must perform all service 1 2 INSTALLATION e For best results place the PNP400 Interconnect Box in a dry area away from dust and moisture indoors only e To prevent fire or shock do not expose this unit to rain or moisture Do not place the PNP400 Interconnect Tabletop Solution in direct sunlight near heaters or heat radiating appliances or near any liquid Exposure to direct sunlight smoke or steam can harm internal components e Handle the PNP400 Interconnect Tabletop Solution carefully Dropping or jarring can damage internal components e Be careful Serious injury could result because of the sharp edges inside of the PNP400 e Do not place heavy objects on top of the PNP400 Do not use excessive force to push down on the top of the unit e To turn off main power disconnect the power cord which powers the power socket on the PNP400 outlets e We recommend using wall outlets with a Ground Fault Circuit Interrupter GFCI for maximum protection e Install all cables according to the instructions Do not force or pull out any cable or power cord that is attached to the PNP400 Interconnect Tabletop Solution 1 3 CLEANING e Surfaces should be cleaned with a dry cloth Never use strong detergents or solvents such as alcohol or thinner Do not use a wet cloth or water to clean the unit SALTINEX Tel 714 990 2300 Toll Free 1 800 ALTINEX FAX 714 990 3303 E mai
7. ess the top of the unit Step 7 To lower the unit push on the top of the PNP400 until it fits into place For more information please refer to the FAQ Section or the Troubleshooting Guide SALTINEX Tel 714 990 2300 Toll Free 1 800 ALTINEX FAX 714 990 3303 E mail solutions altinex com Web www altinex com SIGNAL MANAGEMENT SOLUTIONS DESIGNER SOLUTIONS OPERATION 7 7 1 HOW TO RELEASE GAS SPRING In order to remove and install the gas spring begin with the pop up unit in the down position Apply some pressure in order to compress the gas spring so it will not be ejected with force While the gas spring is compressed remove the side screws from the gas spring support bracket on the bottom of the base unit PNP400 Bottom Remove J screw Z Figure 3 Spring Support Bracket 7 2 HOW TO REMOVE GAS SPRING Unscrew the support bracket from the gas spring On the bottom of the pop up assembly there is a support bracket This bracket has a clearance hole the spring passes through Unscrew the gas spring from the top of the pop up assembly Remove the spring by sliding through the clearance hole in the pop up assembly support bracket 7 3 HOW TO INSTALL GAS SPRING Screw the replacement spring into the top of the pop up assembly Do NOT over tighten The spring should be finger tightened only Attach the spring support bracket to th
8. l solutions altinex com Web www altinex com SIGNAL MANAGEMENT SOLUTIONS DESIGNER SOLUTIONS ABOUT YOUR PNP400 2 The PNP400 is designed for installation into a conference room table The PNP400 Interconnect Tabletop Solution provides a means of connecting A V network and power sources into a presentation system It is ideal for use together with ALTINEX computer video interfaces such as VA6804FC The PNP400 Interconnect Box can pop up into a raised position to provide access to connectors or it can be lowered into a table when not in use The PNP400 uses a tower type construction with gas spring suspension to accomplish this The PNP400 Interconnect Box has two openings on either side of the unit servicing both sides of a table Several optional sectional plates with Computer Video 15 pin HD Composite Video RCA Audio RCA Computer Audio Stereo Mini Modem RJ 11 9 pin D type RS 232 and Network RJ 45 input connections can be used with the PNP400 For additional information regarding optional connectors contact the ALTINEX Sales Department The PNP400 Interconnect Box is designed for use with tables ranging from one to three inches thick The PNP400 comes in a standard matte black color Custom finishes for the top of the PNP400 allow the unit to accent any table top This is available on a custom per order basis at an additional charge TECHNICAL SPECIFICATIONS 3 MECHANICAL PNP400
9. o ensure that specifications have not changed Place the table support brackets under the table and place them between the grooves on the side of the PNP400 unit Place the brackets at the desired height and secure them to the bottom of the table using a setscrew There are two support brackets one for each side of the unit See Figure 1 Step 3 TABLE TOP gt SUPPORT BRACKET SET SCREW SIDE OPENINGS Pd for height adjustments X SUPPORT BRACKET SET SCREW Attachment of the PNP400 to the table using support brackets and set screws Figure 1 Step 4 Secure the cables by using a cable clamp Pass the power cord from the bottom of the housing and attach it to the table using the cable clamp supplied with the PNP400 unit Do not keep the cord too tight or too loose See Figure 2 PNP400 IN AN OPEN POSITION SS E L POWER CORD PASS THE POWER CORD THROUGH THE HOUSING AND ATTACH IT TO A SECURED SURFACE OR TABLE WITH A CABLE CLAMP SIDE VIEW gt Figure 2 Cable Clamp Installation for Service Loop diagram above shows only the power cord not the cables Step 5 Connect the appropriate cables with the correct connectors of the media sources video audio etc being used on the sectional plates Step 6 Once you have connected power and the proper cables to the unit you may raise the unit To raise the PNP400 into position pr
10. shown with special connector plates and cables installed Connectors and cables are not shipped with PNP400 they must be ordered separately For more information regarding connectors and cables designed for the PNP400 contact the ALTINEX Sales Department at 714 990 2300 or visit the ALTINEX website at www altinex com SIGNAL ZALTINEX Tel 714 990 2300 Toll Free 1 800 ALTINEX FAX 714 990 3303 E mail solutions altinex com Web www altinex com DESIGNER SOLUTIONS ORIENTATION SURFACE _ Si FALTINEX 5 Tel 714 990 2300 Toll Free 1 800 ALTINEX FAX 714 990 3303 E mail solutions altinex com Web www altinex com DESIGNER SOLUTIONS INSTALLATION 6 Step 1 The PNP400 ships with a shipping screw To remove the shipping screw push down and turn the spring retaining knob by 90 degrees Then remove the knob from the PNP400 The spring retaining knob is the smallest silver colored knob that is located in the center on the bottom of the unit Re engage the gas spring by pushing down on the retaining knob and turning it back to the original position thereby locking the gas spring into place Step 2 Cut an opening into the table s surface Refer to diagram 3 on page 6 of the manual or the ALTINEX website at www altinex com for table cutout requirements Note The table can be 3 inches or less in thickness Always confirm dimensions before cutting t