1. m The other components attaching to the system have to meet with the IP67 IP43 protection class in order to reach the whole system IP 67 IP43 protection m Empty ports must be sealed with the protective caps supplied 27 Chapter 4 Network Application 4 1 ITU G 8032 Scheme LANTECH G 8032 protocol is following ITU International Telecommunication Unit G 8032 v2 draft The benefits of G 8032 are 1 lt 50ms recovery time when failover 2 G 8032 has defined the protocol scheme parameters functions test measures to be unified that the users can evaluate the possible network infrastructure without literally testing each brand in large scale 4 2 Ring Coupling Redundant Coupling with Multiple Rings 28 4 3 Multiple Rings Dual Rings Major Ring 1 Major Ring 2 Multiple Rings Major Ring 1 Major Ring 2 Major Ring 3 29 4 4 Dual Homing Primary Path Backup Path Major Ring 1 4 5 Chain Multiple Chain Major Ring 1 Sub Ring 3 30 Multiple Chain Share Common Ends Major Ring 1 Sub Ring 3 Cascade Chain Major Ring 1 pn Major Ring 2 Major Ring 3 Chain in Chain Sub Ring 4 Sub Ring 2 Sub Ring 3 31 Chapter 5 Console Management 5 1 Connecting to the Console Port The supplied cable which one end is M12 5 pole connector and the other end is RS 232 connector Attach the end of RS 232 connector to PC or terminal and the other end of M12 connector
2. report EN45545 2 R24 EN ISO 4589 2 EN ISO 5659 2 NF X70 100 1 amp 2 Fire amp Smoke Certificate E Mark E4 Certificate Warranty 5 years Future release Optional Chapter 2 Hardware Description In this paragraph it will describe the Industrial switch s hardware spec port cabling information and wiring installation 2 1 Physical Dimension Aluminum case IP 67 285 W x 201 4 D x 84 4 H mm iis Port description of IP 67 series switch Lantech IPES 5416T 8 4 10 100 1000T 16 10 100TX L2 w 8 PoE at af Industrial Managed Switch x DO Relay i wil Aluminum case IP 43 273 W x 188 4 D x 84 4 H mm 273 00 C16 0 0 0000 0009 kawi gl as neu NA ae oe The port description of IP 43 model is the same as of IP 67 one 15 oe 6 o 8 o 173 00 2 2 Package Content Lantech Manual CD Lantech IPES 5416T Poe ataf Industrial Managed Switch w ITU G 8032 Ring 5 7 ir z E A ma soso z 3 2 Ys A ie i FEE ai bune j 4 3555 0000 sara 2 z 3 amp ii EEEL AR ee 3 Product Console cable 16 2 3 IP Protectio
3. CE EN61000 6 2 CE EN61000 6 4 CE EN61000 4 2 CE EN61000 4 3 CE EN61000 4 4 CE EN61000 4 5 CE EN61000 4 6 CE N61000 4 8 EN61000 4 11 Stability Testing IEC60068 2 32 Free fall EN61373 Shock and Vibration MTBF NA Certifications amp EN50155 EN50121 3 2 EN50121 4 Certificate report EN45545 2 R24 EN ISO 4589 2 EN ISO 5659 2 NF X70 100 1 amp 2 Fire amp Smoke Certificate E Mark E4 Certificate Warranty 5 years IPES 5416T 8 series Future release Optional Standards IEEE 802 3 10Base T Ethernet IEEE 802 3u 100Base TX IEEE802 3z Gigabit fiber IEEE802 3x Flow Control and Back Pressure IEEE802 3ad Port trunk with LACP IEEE802 1d Spanning Tree IEEE802 1w Rapid Spanning Tree IEEE802 1s Multiple Spanning Tree 7 IEEE 802 3ad Link Aggregation Control Protocol LACP IEEE 802 1AB Link Layer Discovery Protocol LLDP IEEE 802 1X User Authentication Radius IEEE802 1p Class of Service IEEE802 1Q VLAN Tag IEEE802 3at af Power over Ethernet Switch Architecture Back plane Switching Fabric 11 2Gbps Packet throughput ability Full Duplex 23 8Mpps 64bytes Transfer Rate 14 880pps for Ethernet port 148 800pps for Fast Ethernet port 1 488 000pps for Gigabit Fiber Ethernet port CPU Marvell 800Mhz RAM 256M Byte Flash 128M Byte Mac Address 16K MAC address table Jumbo frame 9KB on all ports Connectors 10 100T
4. power input voltage can be from 50 4V to 90VDC to feed power on both 802 3af at standardized devices 110V model The power input voltage can be from 77V to 137 5VDC to feed power on both 802 3af at standardized devices Please make sure that the external power supply unit you use to provide the PoE voltage meet the following criteria The output voltage of power supply must exceed 48VDC for 802 3af and 53VDC for 802 3at operation with IPES 5416T 8 72V only 72VDC can power both the 802 3af and 802 3at PD with IPES 5416T 8 110V only 110VDC can power both the 802 3af and 802 3at PD with IPES 5416T 16 72V only 72VDC can power both the 802 3af and 802 3at PD with IPES 5416T 16 110V only 110VDC can power both the 802 3af and 802 3at PD The power consumption can satisfy the total power request from all PD devices required 23 Non PoE model M12 PoE model M23 Power Power PWR1 PWR2 PWR1 PWR2 V V V V NA V V Pin assignment of Power input Hm Dual Power Input The power input can be supported redundantly The supply voltage is electrically isolated from the housing Note With single power supply of the mains voltage the device will report a power failure You can disable this power fail event via web browser DO Relay P Fail 3 24V 4 DO Pin assignment of alarm relay A break in contact is reported via the relay contact The failure of at lea
5. to the console port of the switch The connected terminal or PC must support the terminal emulation program DI Console DI RX 5 2 Login in the Console Interface When the connection between Switch and PC is ready turn on the PC and run a terminal emulation program or Hyper Terminal and configure its communication parameters to match the following default characteristics of the console port Baud Rate 115200 bps Data Bits 8 Parity none Stop Bit 1 Flow control None 32 COM2 Properties 2i xi Port Settings Bits per second Bo H Data bits eo M Parit None v Stop bits hooo Elow control Noes O YS Advanced Restore Defaults The settings of communication parameters Having finished the parameter settings click OK When the blank screen shows up press Enter key to have the login prompt appears Key in admin default value for both User name and Password use Enter key to switch then press Enter and the Main Menu of console management appears Please see below figure for login screen User Name admin Password Console login interface soosscsrss Notic rs22222222222 2 For web based management please refer to our Software Management Manual at http www lantechcom tw global eng support downloads html 33
6. 5 2 Login in the Console Interfface 32 Chapter 1 Introduction Lantech IES 5416T amp IPES 5416T 8 IP67 IP43 series is a high performance L2 IP67 IP43 industrial Gigabit uplink switch with 8x10 100TX 2 GigaT 2Dual Speed Giga FX w 8 PoE at af injectors IPES model by M12 connectors which provides L2 wire speed and advanced security function for connecting PD network Specification IES 5416T series Standards IEEE 802 3 10Base T Ethernet IEEE 802 3u 100Base TX IEEE802 3z Gigabit fiber IEEE802 3x Flow Control and Back Pressure IEEE802 3ad Port trunk with LACP IEEE802 1d Spanning Tree IEEE802 1w Rapid Spanning Tree IEEE802 1s Multiple Spanning Tree IEEE 802 3ad Link Aggregation Control Protocol LACP IEEE 802 1AB Link Layer Discovery Protocol LLDP IEEE 802 1X User Authentication Radius IEEE802 1p Class of Service IEEE802 1Q VLAN Tag Switch Architecture Back plane Switching Fabric 11 2Gbps Packet throughput ability Full Duplex 23 8Mpps 64bytes Transfer Rate 14 880pps for Ethernet port 148 800pps for Fast Ethernet port 1 488 000pps for Gigabit Fiber Ethernet port CPU Marvell 800Mhz RAM 256M Byte Flash 128M Byte Mac Address 16K MAC address table Jumbo frame 9KB on all ports Connectors 10 100TX 16 x ports M12 4 pole D coded with Auto MDI MDI X function 10 100 1000T 4 x ports M12 8 pole A coded with Aut
7. E 1 16 I mode IPES PES 5416T 16 P17 P20 Link Ack On A network device is detected On Off On Off On Off On Off On Off On Off On 20 The port is transmitting or receiving packets from the TX device No device attached 21 Chapter 3 Hardware Installation 3 1Hardware installation 3 1 1Unpack switch and check the accessory with packing content list 3 1 2 Mount the switch on desired position For the best ventilation it is suggested to mount the switch on metallic surface 3 1 3 Connect the M23 M12 connector of power input The PoE power supply for IPES 5416T 8 series is connected via a 5 pole M23 female connector while IES 5416T is with a 5 pole M12 female connector m Voltage of Power Input Non PoE model Standard model The power input voltage can be from 9 5V to 56VDC 72V model The power input voltage can be from 50 4V to 9OVDC 110V model The power input voltage can be from 77V to 137 5VDC PoE model Standard model The voltage of power input should use 48VDC to feed power IEEE 802 3af standardized devices or 54VDC for IEEE 802 3at standardized ones 12V model The power input voltage can be from 22 9 5V to 60VDC to feed power on both the 802 3af and 802 3at standardized devices 24V model The power input voltage can be from 16 8V to 33VDC to feed power on both the 802 3af and 802 3at standardized devices 72V model The
8. Lantech IPES IES 5416T Series 16 10 100TX 4 1000T L2 w 8 or 16 PoE at af Industrial Managed Switch w ITU G 8032 Ring User Manual Hardware Sep 2015 Recommendation for Shielded network cables STP cables have additional shielding material that is used to reduce external interference The shield also reduces the emission at any point in the path of the cable Our recommendation is to deploy an STP network cable in demanding electrical environments Examples of demanding indoor environments are where the network cable is located in parallel with electrical mains supply cables or where large inductive loads such as motors or contactors are in close vicinity to the camera or its cable It is also mandatory to use an STP cable where the power device like IP camera is used outdoors or where the network cable is routed outdoors Aluminum Foil Shield Twisted Pair Wires Important Notice Lantech Communications Global Inc reserves the right to modify the equipment its specification or this manual without prior notice in the interest of improving performance reliability or servicing At the time of publication all data is correct for the operation of the equipment at the voltage and or temperature referred to Performance data indicates typical values related to the particular product No part of this documentation or information supplied may be divulged to any third party without the express written consent of Lante
9. Level 1 10 30V Max input current 8mA 1 Digital Output DO Open collector to 40 VDC 200mA Operating Humidity 5 95 Non condensing Operating 40 C 75 C 40 F 167 F 11 Temperature 72V model 40 C 60 C 40 F 140 F Storage 40 C 85 C 40 F 185 F Temperature Power Supply Standard model 33 6 60VDC dual input 24V model 16 8 33VDC dual input 72V model 50 4 90VDC dual input 110V model 77 137 5VDC dual input PoE Budget 480W for 45 56V input 55V input is recommended for 802 3at 30W applications 120W for 24V input 120W for 72V Input 90W for 110V Input PoE pin M12 port 1 16 support IEEE 802 3at af End point assignment Alternative A mode Per port provides 30W PoE at 15W PoE af 10 100TX Power Max 13W 24V 48VDC input Consumption Max 16W 72VDC 110VDC input Case Dimension IP67 model Aluminum case 285mm W x200mm H x84 4mm D IP43 model Aluminum case 273mm W x187mm H x84 4mm D Weight 2 1kgs IP67 1 8kgs IP43 Installation DIN Rail and Wall Mount Design EMI amp EMS FCC Class A CE EN61000 6 2 CE EN61000 6 4 CE EN61000 4 2 CE EN61000 4 3 CE EN61000 4 4 CE EN61000 4 5 CE EN61000 4 6 CE N61000 4 8 EN61000 4 1 1 Stability Testing IEC60068 2 32 Free fall EN61373 Shock and Vibration MTBF 203 334 hrs Certifications amp EN50155 EN50121 3 2 EN50121 4 Certificate 12
10. X 16 x ports M12 4 pole D coded with Auto MDI MDI X function 10 100 1000T 4 x ports M12 8 pole A coded with Auto MDI MDI X function RS 232 connector 1 x M12 5 pole A coded Power Input connector 1 x M23 5 pole A coded Relay contact 1 x M12 5 pole A coded Network Cable 10Base T 2 pair UTP STP Cat 3 4 5 5E 6 cable EIA TIA 568 100 ohm 100m 100Base TX 2 pair UTP STP Cat 5 5E 6 cable EIA TIA 568 100 ohm 100m 1000Base TX 2 pair UTP STP Cat 5 5E 6 cable EIA TIA 568 100 ohm 100m Bypass Protection High speed optical switching lt 4ms Minimal insertion loss Max 1 6dB as Bypass Mode Protocol CSMA CD LED Per unit Power 1 Green Power 2 Green P Fail Red Ethernet port Link Activity Green Speed Green Optical fiber Link Activity Green DI DO 1 Digital Input DI Level 0 30 2V Level 1 10 30V Max input current 8mA 1 Digital Output DO Open collector to 40 VDC 200mA Operating 5 95 Non condensing Humidity Operating 40 C 75 C 40 F 167 F Temperature 72V model 40 C 60 C 40 F 140 F Storage 40 C 85 C 40 F 185 F Temperature Power Supply Standard model 45 56VDC dual input 12V model 9 5 60VDC dual input 72V model 50 4 90VDC dual input 110V model 77 137 5VDC dual input PoE Budget 240W for 45 56V input 48V model 55V input is recommended for 802 3at 30W applications 80W for 12V inpu
11. ch Communications Global Inc Products offered may contain software which is proprietary to Lantech Communications Global Inc The offer or supply of these products and services does not include or infer any transfer of ownership Interference Issues This Equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a commercial or industrial installation This equipment generates uses and can radiate radio frequency energy It may cause harmful interference to radio communications if the equipment is not installed and used in accordance with the instructions FCC Warning This Equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy It may cause harmful interference to radio communications if the equipment is not installed and used in accordance with the instructions However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is en
12. couraged to try to correct the interference by one or more of the following measures Hm Reorient or relocate the receiving antenna m Increase the separation between the equipment and receiver Hm Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Hm Consult the dealer or an experienced radio TV technician for help CE Mark Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Content Chapter 1 Introduction cccccceesseeeesseseeeeeeeeeeeeees 5 SD CCIICALION GS et desis aa ak ak E a NA a a an Aa aab EN as 5 Chapter 2 Hardware Description ece 14 2 1 Physical DIMe nSloM saris sxcccetie veces x rencatveens 14 2 2 Package Content akasa aka aa aaa a Na a NA 16 2 3 IE PTOtECUO ji saka aaa aji aa aa a PAE ajaa 17 24 LED IMGICATONS sic aana ance axes sas LATA Apa gag TA kana ka 20 Chapter 3 Hardware Installation c0 22 Chapter 4 Network Application ccccccee 28 4 1 ITU G 8082 Scheme cccceeeeeeeeeeeseeeeeeees 28 4 2 FRING COUINO serna 28 4 3 Multiple RiNS icena 29 4 4 Dual Homing ccceeeceeeeeeeeeeeeeeeeeeeeaeeeeeees 30 BOs CMGI caste Seales altura ga nan aaa ak aa a 30 Chapter 5 Console Management c0000 32 5 1 Connecting to the Console Port 32
13. ersed in water under defined conditions of pressure and time up to 1 m of submersion The equipment is suitable for continuous immersion in water under conditions which shall be specified by the manufacturer Normally this will mean that the equipment is hermetically sealed However with certain types of equipment it can mean that water can enter but only in such a manner that it produces no harmful effects Protected against close range high pressure high temperature spray downs 19 Test duration at least 3 minutes Water volume 100 litres per minute Pressure 100 kPa at distance of 3 m Test duration 30 minutes Immersion at depth of at least 1 m measured at bottom of device and at least 15 cm measured at top of device Test duration continuous immersion in water Depth specified by manufacturer 2 4 LED Indicators The diagnostic LEDs that provide real time information of system and optional status are located on the front panel of the industrial switch The following table provides the description of the LED status and their meanings for the switch fic RK NENENG on resets Tg KANAN Ka KE AA KANAN LEA NANA KANAN LEAK NANA o pem a peo o pe a pe on pee U O The port is transmitting or receiving packets Link Ack Blinking from the TX device No device attached PoE 1 8 IP The port is operating in PoE mode IPES oe on ES 5416T 8 The port is not operating in PoE Po
14. n The IP Code Ingress Protection Rating sometimes also interpreted as International Protection Rating classifies and rates the degree of protection provided against the intrusion including body parts such as hands and fingers dust accidental contact and water in mechanical casings and with electrical enclosures It is published by the International Electrotechnical Commission IEC Solid particle protection The first digit indicates the level of protection that the enclosure provides against access to hazardous parts e g electrical conductors moving parts and the ingress of solid foreign objects Object size i Level Effective against protected against 0 No protection against contact and ingress of objects Any large surface of the body such as the back of a 1 gt 50 mm hand but no protection against deliberate contact with a body part 2 gt 12 5 mm Fingers or similar objects 3 gt 2 5 mm Tools thick wires etc 4 gt 1 mm Most wires screws etc Ingress of dust is not entirely prevented but it must not enter in sufficient quantity to interfere with the 5 Dust protected satisfactory operation of the equipment complete protection against contact No ingress of dust complete protection against 6 Dust tight contact 17 Liquid ingress protection The second digit indicates the level of protection that the enclosure provides against harmful ingress of water Level Protected against No
15. o MDI MDI X function RS 232 connector 1 x M12 5 pole A coded Power Input connector 1 x M12 5 pole A coded Relay contact 1 x M12 5 pole A coded Network Cable 10Base T 2 pair UTP STP Cat 3 4 5 5E 6 cable EIA TIA 568 100 ohm 100m 100Base TX 2 pair UTP STP Cat 5 5E 6 cable EIA TIA 568 100 ohm 100m 1000Base TX 2 pair UTP STP Cat 5 5E 6 cable EIA TIA 568 100 ohm 100m Bypass High speed optical switching lt 4ms Protection Minimal insertion loss Max 1 6dB as Bypass Mode Protocol CSMA CD LED Per unit Power 1 Green Power 2 Green P Fail Red Ethernet port Link Activity Green Speed Green DI DO 1 Digital Input DI Level 0 30 2V Level 1 10 30V Max input current 8mA 1 Digital Output DO Open collector to 40 VDC 200mA Operating 5 95 Non condensing Humidity Operating 40 C 75 C 40 F 167 F Temperature 72V model 40 C 60 C 40 F 140 F Storage 40 C 85 C 40 F 185 F Temperature Power Supply Standard model 9 5 56VDC dual input 72V model 50 4 90VDC dual input 43 2 100 8VDC 100ms 110V model 77 137 5VDC dual input 66 154VDC 100ms Power Consumption Max 13W 12V 48VDC input Max 16W 72VDC 110VDC input Case IP67 model Aluminum case Dimension 285mm W x200mm H x84 4mm D IP43 model Aluminum case 273mm W x187mm H x84 4mm D Weight 2 1kgs IP67 1 8kgs IP43 Installation DIN Rail and Wall Mount Design EMI amp EMS FCC Class A
16. ol LACP IEEE 802 1AB Link Layer Discovery Protocol LLDP IEEE 802 1X User Authentication Radius IEEE802 1p Class of Service IEEE802 1Q VLAN Tag IEEE802 3at af Power over Ethernet Switch Architecture Back plane Switching Fabric 11 2Gbps Packet throughput ability Full Duplex 23 8Mpps 64bytes 10 Transfer Rate 14 880pps for Ethernet port 148 800pps for Fast Ethernet port 1 488 000pps for Gigabit Fiber Ethernet port CPU Marvell 800Mhz RAM 256M Byte Flash 128M Byte Mac Address 16K MAC address table Jumbo frame 9KB on all ports Connectors 10 100TX 16 x ports M12 4 pole D coded with Auto MDI MDI X function 10 100 1000T 4 x ports M12 8 pole A coded with Auto MDI MDI X function RS 232 connector 1 x M12 5 pole A coded Power Input connector 1 x M23 5 pole A coded Relay contact 1 x M12 5 pole A coded Network Cable 10Base T 2 pair UTP STP Cat 3 4 5 5E 6 cable EIA TIA 568 100 ohm 100m 100Base TX 2 pair UTP STP Cat 5 5E 6 cable EIA TIA 568 100 ohm 100m 1000Base TX 2 pair UTP STP Cat 5 5E 6 cable EIA TIA 568 100 ohm 100m Bypass Protection High speed optical switching lt 4ms Minimal insertion loss Max 1 6dB as Bypass Mode Protocol CSMA CD LED Per unit Power 1 Green Power 2 Green P Fail Red Ethernet port Link Activity Green Speed Green DI DO 1 Digital Input DI Level 0 30 2V
17. st one of the two supply voltages The break link status of at least one switch port 3 1 4 Fitting the device grounding Install the system in a dry and clean area to protect the switch to 24 get exposed with dirt Plug the connector to the power supply plug then turn on the power supply E Ground The chassis is grounded via a separate ground nut M3 Use toothed locking washers for a good electrical connection Ground screw of IPES 5408T switch 3 1 5 Connect the M12 connector with RJ 45 data cable ports are not used shall be caped that comes with the package to insulate the surrounding 25 e White 1 TX 2 RX 3 TX 4 RX TX lt gt Orange White RX lt gt Green White TX lt gt Orange RX lt gt Green 2 Green White RxD Receive Data TxD Transmit Data TxD Transmit Data Shield Cable shield Signal Ground T 568B 8 NC unused 12345678 8 7 NC unused 6 RxD Receive Data Ethernet 5 NC unused RJ45 4 NC unused 3 2 1 Ethernet RJ45 3 C Green Te w ik lam TT orange whe 6 _ I Pin assignment of M12 10 100 100T network connector TWIST 26 10 100TX 10 100 1000T 1 TX 1 BID3 5 RXD2 2 RX 2 BID4 6 TXD1 3 TX 3 BID4 7 BID3 4 RX 4 TXD1 8 RXD2 3 1 6 Check the status of LED make sure the switch was in working status Note m The protection class IP67 IP43 is only achieved when bolted together
18. t 12V model 120W for 24V input 12V model 80W for 72V Input 72V model 80W for 110V Input 110V model 80W for WV input model 16 8V 137 5V PoE pin M12 port 1 8 support IEEE 802 3at af End point assignment Alternative A mode Per port provides 30W PoE at 15W PoE af 10110074 Power Max 13W 12V 48VDC input Consumption Max 16W 72VDC 110VDC WV_ input Case Dimension IP67 model Aluminum case 285mm W x200mm H x84 4mm D IP43 model Aluminum case 273mm W x187mm H x84 4mm D Weight 2 1kgs IP67 1 8kgs IP43 Installation DIN Rail and Wall Mount Design EMI amp EMS FCC Class A CE EN61000 6 2 CE EN61000 6 4 CE EN61000 4 2 CE EN61000 4 3 CE EN61000 4 4 CE EN61000 4 5 CE EN61000 4 6 CE N61000 4 8 EN61000 4 1 1 Stability Testing IEC60068 2 32 Free fall EN61373 Shock and Vibration MTBF 217 019 hrs Certifications amp report EN50155 EN501 21 3 2 EN50121 4 Certificate EN45545 2 R24 EN ISO 4589 2 EN ISO 5659 2 NF X70 100 1 amp 2 Fire amp Smoke Certificate Warranty 5 years IPES 5416T 16 series Future release Optional Standards IEEE 802 3 10Base T Ethernet IEEE 802 3u 100Base TX IEEE802 3z Gigabit fiber IEEE802 3x Flow Control and Back Pressure IEEE802 3ad Port trunk with LACP IEEE802 1d Spanning Tree IEEE802 1w Rapid Spanning Tree IEEE802 1s Multiple Spanning Tree IEEE 802 3ad Link Aggregation Control Protoc
19. t protected Dripping water Dripping water when tilted up to 15 Spraying water Splashing of water Water jets Testing for Dripping water vertically falling drops shall have no harmful effect Vertically dripping water shall have no harmful effect when the enclosure is tilted at an angle up to 15 from its normal position Water falling as a spray at any angle up to 60 from the vertical shall have no harmful effect Water splashing against the enclosure from any direction shall have no harmful effect Water projected by a nozzle 6 3 mm against enclosure from any direction shall have no harmful effects 18 Details Test duration 10 minutes Water equivalent to 1 mm rainfall per minute Test duration 10 minutes Water equivalent to 3 mm rainfall per minute Test duration 5 minutes Water volume 0 7 litres per minute Pressure 80 100 kPa Test duration 5 minutes Water volume 10 litres per minute Pressure 80 100 kPa Test duration at least 15 minutes Water volume 12 5 litres per minute Pressure 30 kPa at distance of 3m 8 Powerful water jets Immersion up to 1m Immersion beyond im Powerful high temperature water jets Water projected in powerful jets 12 5 mm nozzle against the enclosure from any direction shall have no harmful effects Ingress of water in harmful quantity shall not be possible when the enclosure is imm