Home

S 3331 SPLIT AIR CONDITIONER

image

Contents

1. C dB dB type R gr m m Liquid side mm Gas side mm mm mm IP IP kg kg years 5 8 A 186 3 1 3 8 A 1154 W A C 3 0 2 699 0 501 Qlima white 8713508767390 8713508767406 Cooling Heating 1 0 4 0 1 0 4 2 0 96 0 89 230 50 1 10 5 420 550 565 80 100 26 0 50 15 30 17 30 25 56 3 positions electronic remote Screen active carbon 3M HAF R410A 800 1975 20 8 6 35 1 4 9 52 3 8 800x275x188 780x540x250 rotary GMCC IP 20 IP 24 7 30 4 8713508752587 EAN Code S 3331 SPLIT AIR CONDITIONER 3 functions in 1 Inverter technology Extra frost protection in outdoor unit Anti corrosion treatment Home freezing preven tion Environmental friendly refrigerant 3 layer filter Remote control with LCD display Features Cooling dehumidifying heating heat pump The air conditioning is a complete air treatment system It can cool dehumidify and heat the air Air conditioning In COOLING mode the unit produces a pleasant and refreshing cool airflow Heating In HEATING mode the unit produces a warm and comfortable airflow Because also the free of charge energy from the outdoor air is used to increase the efficiency of the system Dehumidifying In DRY mode the unit dehumidifies the air in the room as efficient as possible Note In COOLING mode the air is also dehumidified Inverter technology maximum comfort The
2. Qlima DC Inverter Wall Mounted Split air conditioner continuously adjusts the cooling and heating capacity according the desired room temperature When the desired temperature is reached the compressor speed is gradually decreased to maintain the room temperature with a minimum of variation By varying gradually the compressor capacity the expected lifetime as well as the experienced comfort level will increase Looking at the experienced comfort level for the user of the inverter system Non inverter air conditioners which operate at a constant speed must turn on off the compressor to control the room temperature causing less comfortable temperature fluctuations Inverter technology minimum energy consumption The compressor starts to slow down as the room temperature reaches the desired temperature As a result the over all power consumption is reduced significantly up to 35 less than non inverter conventional types EXTRA frost protection in outdoor unit The outdoor unit is provided with a PTC heating cable When the system is working as a heater in the wintertime the PTC heating cable will keep the drip pan in the outdoor unit clear of ice making sure the condensate water can reach the drain point Furthermore also the compressor crankcase is provided with a heating cable Ensuring the unit can perform and start up at extreme wheather conditions EXTRA anti corrosion treatment in outdoor unit The Qlima Golden Fin corrosion treatment on
3. the outdoor condenser heat exchanger improves the heating efficiency and accelerates the defrosting process The unique anti corrosive Golden Fin coating can withstand salty air and rain in a superb way resulting in a longer expected lifetime of the condenser EXTRA Home Freezing prevention Button Upon pressing this button the unit will go into the freezing prevention mode The unit will overrule the indoor temperature setting and set it to approx 8 10 C In this way preventing your home from freezing during cold periods at the lowest possible energy consumption When this mode is selected the indoor unit display will show FP This button can only be operated in heating mode Environment friendly refrigerant R410A The most preferred and environmental friendly refrigerant R410a is used in the air conditioner Automatic low sound mode This air conditioner is equipped with a special automatic low sound mode which will be automatically activated when the room temperature has reached the desired set point temperature In this automatic mode the air conditioner will operate on a whispering quiet level Turbo mode With the Turbo mode the air conditioner will reach the preset temperature in the shortest possible time 3 layer air filter The air conditioner is equipped with a 3 layer filter package to clean the circulated room air The 3M HAF air filter delivered together with this unit captures allergens like bacteria dust and pollen fr
4. S 3331 Download photos and docs on qlima com en aa aiani P R PEH EE Hh falii HH AH HH UUEOOGERREREY Qlima cea J 20 ft 113 WxDxH Gross 40 ft 232 in 865x350x265mm 9 kg HQ 266 out 910x585x335mm 32 kg Qlima HOME MADE CLIMATES SPLIT AIR CONDITIONER Product data sheet Brand name Model Sound power level indoor Sound power level outdoor dB A dB A Qlima 3331 57 64 Refrigerant leakage contributes to climate change Refrigerant with lower global warming potential GWP would contribute less to global warming than a refrigerant with higher GWP if leaked to the atmosphere This appliance contains a refrigerant fluid Refrigerant GWP with a GWP equal to 1975 This means that if 1 kg of this refrigerant fluid would be leaked to the 1975 atmosphere the impact on global warming would be 1975 times thigher than 1 kg of CO2 over a period of 100 years Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional SEER energy efficiency class average season Indicative annual electricity consumption during cooling season Qce Design load capacity in cooling mode SCOP energy efficiency class Indicative annual electricity consumption during average heating season Qhe Declared suitable regions W A C Design load capacity in heating mode Declared capacity at reference d
5. esign condition heating average season Back up heating capacity at reference design condition heating average season Product specifications Colour EAN code indoor unit EAN code outdoor unit Technical specifications Capacity min max Power consumption nom Power supply Current max Air flow min max For rooms up to Dehumidification capacity Operating range Thermostatic range Sound pressure level indoor low Sound pressure level outdoor Fan speed Control Air filter Refrigerant type charge Refrigerant GWP Max length refr pipe between in outdoor unit Max diff in height between in outdoor unit Diameter for connection Dimensions indoor w x h x d Dimensions outdoor w x h x d Compressor type Protection class indoor Protection class outdoor Weight indoor Weight outdoor Guarantee 1 Measured conform EN 14825 EN 14511 2011 EN 12102 2008 2 To be used as indication 3 Moisture removal at 32 C 80 RH Precharge sufficient for max 5 meters piping When over 5 mtrs additional refrigerant is needed check manual 74 years on compressor 2 years on other components Accessories Remote control ABS 10FP Remote control holder 2 pcs AAA batteries 4 metres drainage tube User manual Installation manual Most important spare parts Spare part description kWh a Pdesignc kW kWh a Pdesignh kW kW kW kW kW V Hz Ph A m h m L 24 h C
6. om the circulated air with an efficiency up to 80 Pollen are well known as an important stimulus for hay fever allergy The active carbon filter removes unpleasant odours from the air and the screen filter captures large dust particles The screen filter can be cleaned with a vacuum cleaner and or lukewarm water Per season 2 to 3 3M HAF and active carbon filters will be used These filters are available in a consumer package including 1 3M HAF and 1 active carbon filter Remote control with LCD screen The unit can be operated with an easy to handle remote control including LCD display Using the remote control the air conditioner can be operated up to a distance of approx 8 metres Remote control holder The remote control can be placed in the wall mounted remote control holder which is delivered together with the unit Adjustable airflow The up down airflow can be automatically changed by using the SWING mode The left right airflow can be changed manually Sleep Mode This function enables the air conditioner to increase cooling or decrease heating automatically 1 C per hour for the first two hours and then maintain the same temperature for five hours after which the air conditioner will stop operating automatically It maintains the most comfortable temperature and saves energy at the same time Fan speed setting Select with FAN speed button Automatic Low Medium or High The LCD display on the remote control will
7. show the chosen speed Automatic operation The air conditioning system can be set to automatic operation for the most suitable MODE Cooling Dehumidifying or Heating monitoring the indoor temperature Auto restart function If there is any power failure during operation the operation status before power failure is memorised and the unit starts operating automatically after power recovery Timer Use TIMER or set a working time between 30 minutes and 24 hours The preset time appears in the display of the remote control The unit switches ON or OFF automatically when this time is passed Standby mode This energy saving feature enables the unit to stay in standby mode only 1 W energy consumption Full colour box The unit is delivered completely with all auxiliary parts in a full colour box showing application and operation information in multiple languages

Download Pdf Manuals

image

Related Search

Related Contents

補助手摺I型・L型  Blanco 501-111 User's Manual  Farberware FPC800V Use & Care Manual  [第1版][第2版][第3版]  Graco 333389A- User's Manual  LG LFX29927ST Energy Guide  対話型電子白板を利用した教育ソフトウェアの有効 - NPO koganei-net  Rexel Stratis Cabinets 30 Drawers  platform phone through tcp / ip muhammad affandy  

Copyright © All rights reserved.
Failed to retrieve file