1. by ENTER If the procedure has been done correctly you will hear two beeps and the green light flashes In case of entry errors long beep and red light the old code remains active and you can try again Programming the user code with master code 1 Enter ON followed by ENTER 2 ENTER 2 Enter the current master code followed by ENTER 3 Enter the new user code 6 to 8 digits followed by ENTER 4 Repeat the new user code followed by ENTER The signals sound and light are the same as when programming the master code Programming the user code without master code 1 Enter ON followed by ENTER 3 ENTER 2 Enter current user code followed by ENTER 3 Enter the new user code 6 to 8 digits followed by ENTER 4 Repeat the new user code followed by ENTER The signals sound and light are the same as when programming the master code Delete user code 1 Enter ON followed by ENTER 0 ENTER 2 Enter the current master code followed by ENTER 3 The user code has now been deleted The master code is now the only valid code The signals sound and light are the same as when programming the master code Opening delay opening frame Opening delay you can open the lock after the expiry of a certain period of time Opening frame a time period during which it is possible to open the lock by entering a valid passw
2. User manual Salvus electronic lock Safe series Salvus Monopoli Salvus Monza and Salvus Palermo General information e This lock can be programmed with one or two 6 to 8 digit code s e Every key entry is confirmed with a short beep and flashing of the green light e If no key is entered within 10 seconds the lock will automatically turn off e The lock can optionally be programmed with an opening delay and opening frame period Opening the safe door The master code is 1 2 3 4 5 6 upon first usage The user code is deactivated by default 1 Enter ON you will hear a signal and the green light is on 2 Enter master code or user code followed by ENTER 3 Open safe door within 5 seconds Closing and locking the safe door 1 Close the door and turn handle fully to closing position The lock is secured Check by trying to turn the handle back Manipulation protection If the entered code is wrong you will hear a long signal and the red light is on Entry of three consecutive wrong codes will block the key pad for five minutes During this period the red light flashes every five seconds Attention All programming procedures must be done with an open door Programming the master code 1 Enter ON followed by ENTER 1 ENTER 2 Enter the current master code followed by ENTER 3 Enter the new master code 6 to 8 digits followed by ENTER 4 Repeat the new master code followed
3. ord combination after the opening delay is finished Programming opening delay opening frame 1 Enter ON enter a valid code followed by ENTER and open the lock Enter ON ENTER 6 and ENTER Repeat the valid code followed by ENTER Enter a two digit number for the opening delay 01 99 minutes Enter a one digit number for the opening frame 1 9 minutes followed by ENTER Test the programmed functions by closing and opening the lock one more time with open door eS wW a Opening the safe door in case of opening delay opening frame 1 Enter ON you will hear a signal and the green light is on Enter master code or user code followed by ENTER Start of opening delay period the red LED will flash every 5 seconds As soon as the opening delay expires you will hear an acoustic signal Start of opening frame period acoustic and red LED signals every 5 seconds Enter master code or user code followed by ENTER before the opening frame period expires Open safe door within 5 seconds SO St W Cancelling programmed opening delay opening frame 1 Enter ON enter a valid code followed by ENTER and open the lock 2 Enter ON ENTER 6 and ENTER 3 Repeat the valid code followed by ENTER 4 Enter 0 0 0 followed by ENTER to cancel the opening delay and opening frame Acoustic signal on off During the opening frame yo
4. u will see the red LED signal and hear an acoustic signal every five seconds It is possible to turn this signal on or off according to your own preference 1 Enter ON ENTER 5 and ENTER 2 Enter a valid code followed by ENTER The acoustic signal is now turned on or off Battery and emergency power supply The lock is powered by a 9V Alkaline battery 6LR61 If the battery is almost battery you will hear a signal while the red light flashes five times after you press ON You can now only open the safe Programming the lock is not possible You should replace the battery as soon as possible Unscrew the battery cover on the inside of the door Take out the old battery replace it with a new one and put the cover back Test the opening and closing a few times with opened door On the keypad you will find the emergency power supply in case the battery is completely empty To open the safe please follow the normal opening procedure while you hold a 9V battery against the and After opening the safe replace the empty battery

Download Pdf Manuals

image

Related Search

Related Contents

LB01 User Manual  キャッチコピー300選  Notice - Castorama  WHI 1628 A 0908.indd    HP ac200w User's Manual  Intermec IF30  クロネコメール便の廃止について  Manual - Cateye  

Copyright © All rights reserved.
Failed to retrieve file