Contents
1. 74 5 6 Extender Settings 77 5 7 CPU Settings 80 5 8 Console Settings 84 5 8 1 CON Devices 84 5 8 2 Mouse and Keyboard 88 5 9 Saving and Loading of Configurations 90 5 9 1 Active Configuration 91 5 9 2 Saving of Configurations internal 91 5 9 3 Loading of Configurations internal 93 5 9 4 Saving of Configurations external 95 Contents 2011 10 11 5 5 9 5 Loading of Configurations external 96 5 10 Export and Import Options 97 5 10 1 Export Options 98 5 10 2 Import Options 99 5 11 Firmware Update 100 5 11 1 Matrix Update 100 5 11 2 Extender Update 101 6 Operation
2. 104 6 1 Operation via Hot Keys 105 6 1 1 Direct Switching 105 6 1 2 Scan Mode 106 6 1 3 Addressing of Main and Sub Matrices 106 6 1 4 Function Keys lt F1 gt lt F12 gt 107 6 2 KVM Switching 107 6 3 Serial Interface 110 6 4 Power On and Power Down Functions 111 6 4 1 Restart 111 6 4 2 Reset 111 6 4 3 Power Down 111 7 Specifications 112 7 1 Interfaces 112 7 1 1 DVI D Single Link 112 7 1 2 USB HID 112 7 1 3 RJ45 Network 113 7 1 4 RS 232 Serial 113 7 1 5 RJ45 Interconnect
3. 113 7 1 6 Fiber SFP Type LC Interconnect 113 7 1 7 SDI Interconnect 114 7 2 Interconnect Cable 114 7 2 1 Cat X 114 7 2 2 Fiber 116 7 2 3 Coaxial 117 Draco tera 6 2011 10 11 7 3 Supported Peripherals 117 7 3 1 KVM Extenders 117 7 3 2 USB 2 0 Extender 119 7 3 3 Video Extender 119 7 4 Serial Control 120 7 4 1 Telegrams of the Switching Functions 122 7 5 Connector Pinouts 133 7 5 1 CPU Board 133 7 5 2 I O Board Cat X 134 7 5 3 I O Board SFP 134 7 5 4 I O Board SDI 135 7 6 Power Supply
4. 135 7 7 Environmental Conditions 135 7 8 Size 136 7 9 Shipping Weight 137 8 Troubleshooting 138 8 1 External Failure 138 8 2 Video Interference 138 8 3 Malfunction of Fans 138 8 4 Malfunction of Power Supply Units 139 8 5 Network Error 139 8 6 Failure at the Matrix 139 8 7 Blank Screen 140 9 Technical Support 141 9 1 Support Checklist 141 9 2 Shipping Checklist 141 10 Certificates 142 10 1 CE Declaration Of Conformity 142 10 2 North Am
5. 38 5 Configuration 40 5 1 Command Mode 40 5 2 Control Options 41 5 2 1 Control via OSD 42 5 2 2 Control via Java Tool 47 5 2 3 Control via Serial Interface 54 5 3 Assignment 54 5 3 1 Virtual CPU to real CPU 55 5 3 2 Real Console to Virtual Console 56 5 4 System Settings 58 5 4 1 System Data 58 5 4 2 Automatic ID 61 5 4 3 Access 63 5 4 4 Switch 67 5 4 5 Network 70 5 4 6 Date and Time 72 5 5 User Settings 74 5 5 1 User Data
6. 7 1 1 Scope 7 1 2 Validity 7 1 3 Cautions and Notes 7 1 1 Spellings 7 2 Safety Instructions 8 3 Description 9 3 1 Application 9 3 2 Access Options 9 3 3 System Overview 10 3 4 Product Range 11 3 5 Accessories 11 3 6 Device Views 13 3 6 1 Draco tera 288 Port 13 3 6 2 Draco tera 160 Port 14 3 6 3 Draco tera 80 Port 15 3 6 4 Draco tera 48 Port 16 3 6 5 Draco tera 8
7. 3 Note your RMA number visibly on your shipment Devices that are sent in without a RMA number cannot be accepted The shipment will be sent back without being opened postage unpaid Pos 125 806 IHSE Zertifikate UEB_Zertifikate 5 mod_1278579534933_6 doc 42668 1 1 Draco tera 142 2011 10 11 10 Certificates Pos 126 806 IHSE Zertifikate ATB_Europ ische Konformit tserkl rung 5 mod_1278579640901_6 doc 42686 2 1 10 1 CE Declaration Of Conformity The products listed below in the form as delivered comply with the provisions of the following European Directives 2004 108 EG Council Directive on the approximation of the laws of the Member States relating to electromagnetic compatibility CE Marking 2009 Product list 480 Series The products comply with the following harmonized standards for Information Technology Equipment EN 55022 2006 A1 2007 Class A EN 55024 1998 A1 2001 A2 2003 This declaration certifies the conformity to the specified directives but contains no assurance of properties The safety instructions and installation guidelines noted in this manual shall be considered in detail Compliance with the specifications for cable lengths and types is mandatory Manufacturer IHSE GmbH Maybachstrasse 11 88094 Oberteuringen Deutschland Oberteuringen 26 January 2010 The Management Use in a Domestic Environment This is a Class A product In a domestic
8. 1 Command 0x54 2 Total length of telegram 7 bytes binary 0x07 0x00 2 Total number of CPUs 0x01 0x00 for 1 CPU to 0x11F 0x00 for 287 CPUs Example Connection of console 23 with CPU 43 with 50 CPUs in total 0x1B 0x5B 0x54 0x07 0x00 0x32 0x00 0x2B 0x00 0x17 0x00 Connection of CON Input with CPU Output and CPU Input with CON Output Bytes Description Coding 1 Control character 0x1B 1 Server identification 0X5B 1 Command 0x55 2 Total length of telegram 9 bytes binary 0x09 0x00 2 Requested CPU 0x01 0x00 for CPU 1 to 0x11F 0x00 for CPU 287 2 Requested console 0x01 0x00 for console 1 to 0x11F 0x00 for console 287 Example Connection of console 23 input with CPU 43 output 0x1B 0x5B 0x55 0x09 0x00 0x2B 0x00 0x17 0x00 Draco tera 132 2011 10 11 Connection of CON Input with CPU Output and CPU Input with CON Output with a fixed CPU Number Bytes Description Coding 1 Control character 0x1B 1 Server identification 0X5B 1 Command 0x56 2 Total length of telegram 7 bytes binary 0x07 0x00 2 Total number of CPUs 0x01 0x00 for 1 CPU to 0x11F 0x00 for 287 CPUs Example Connection of console 23 with CPU 43 and console 24 with CPU 44 with 50 existing CPUs 0x1B 0x5B 0x56 0x07 0x00 0x32 0x00 0x2B 0x00 0x17 0x00 0x2C 0x00 0x18 0x00 Pos 99 806 IHSE Technische Daten Pinbelegungen UEB_Pinbelegungen 5 mod_1278578683636_6 doc
9. 1 n c 6 DTR 2 CTS 7 TxD 3 RTS 8 RxD 4 DSR 9 n c 1 5 6 9 5 GND Pos 104 806 IHSE Technische Daten Pinbelegungen 480 xx RJ45 7 mod_1309943226649_6 doc 53857 4 RJ45 Picture Pin Signal Pin Signal 1 D1 5 n c 2 D1 6 D2 3 D2 7 n c 8 1 4 n c 8 n c Pos 105 806 IHSE Technische Daten Pinbelegungen UEB_E A Karte Cat X 7 mod_1309943361243_6 doc 53876 4 7 5 2 I O Board Cat X Pos 106 806 IHSE Technische Daten Pinbelegungen RJ45 5 mod_1278578820011_6 doc 42405 1 RJ45 Picture Pin Signal Pin Signal 1 D1 5 D3 2 D1 6 D2 3 D2 7 D4 8 1 4 D3 8 D4 Pos 107 806 IHSE Technische Daten Pinbelegungen UEB_E A Karte SFP 7 mod_1309943436008_6 doc 53894 4 7 5 3 I O Board SFP Pos 108 806 IHSE Technische Daten Pinbelegungen Glasfaser SFP Typ LC 5 mod_1278938501151_6 doc 43210 1 Fiber SFP Typ LC Picture Diode Signal 1 Data OUT 1 2 2 Data IN Pos 109 806 IHSE Technische Daten Pinbelegungen UEB_E A Karte SDI 7 mod_1309943510165_6 doc 53912 4 Specifications 2011 10 11 135 7 5 4 I O Board SDI Pos 110 806 IHSE Technische Daten Pinbelegungen Mini BNC SDI 7 mod_1309943545633_6 doc 53930 4 Mini BNC SDI Picture Pin Signal 1 Data IN 1 2 2 GND Pos 111 806 IHSE Technische Daten Stromversorgung 480 x
10. 4 Specifications 2011 10 11 137 7 9 Shipping Weight Draco tera 288 Matrix 34 6 kg 76 2 lb fully equipped Shipping Box 41 1 kg 90 6 lb Draco tera 160 Matrix 26 3 kg 60 0 lb fully equipped Shipping Box 31 7 kg 69 9 lb Draco tera 80 Matrix 11 1 kg 24 5 lb fully equipped Shipping Box 15 6 kg 34 4 lb Draco tera 48 Matrix 8 9 kg 19 6 lb fully equipped Shipping Box 12 1 kg 26 7 lb Draco tera 8 Matrix Shipping Box Pos 115 806 IHSE Hilfe im Problemfall UEB_Hilfe im Problemfall 5 mod_1278579113839_6 doc 42536 1 1 Draco tera 138 2011 10 11 8 Troubleshooting Pos 116 806 IHSE Hilfe im Problemfall Hilfe im Problemfall 480 xx 7 mod_1309943852774_6 doc 54002 4 In the following chapters support for problems with the Draco tera matrix is provided This help is based as regards content on a functional extender route Please ensure before running your extenders with the matrix that they work over a peer to peer connection This can be supported by the use of a Cat X or fiber coupler If you have problems referring to this the manuals of the respective extenders will offer support Pos 117 806 IHSE Hilfe im Problemfall Externe St rung 480 xx 7 mod_1309944289555_6 doc 54021 4 8 1 External Failure Diagnosis Possible Reason Measure Matrix cannot be started anymore Fuse at the standard appliance outlet Check fuse Pos 118
11. Network Pos 48 806 IHSE Konfiguration Systemeinstellung 480 xx Datum und Uhrzeit 7 mod_1309938224352_6 doc 53140 4 5 4 6 Date and Time Date and Time are set in this menu You have the following possibility to access the menu You can select between the following settings Field Selection Description Month 1 12 Enter month Date 1 31 Enter date Year 1 99 Enter year Day of the week 1 7 Enter week Hours 0 23 Enter hour Minutes 0 59 Enter minute Configuration 2011 10 11 73 Field Selection Description Seconds 0 59 Enter second Date format according to the English notation OSD Select Configuration gt Date Time in the main menu Menu Configuration Date Time You can select between the following buttons Button Function Cancel Reject changes Save Save changes Pos 49 806 IHSE Konfiguration Benutzereinstellungen 480 xx Benutzereinstellungen User 7 mod_1309938277711_6 doc 53160 4 Draco tera 74 2011 10 11 5 5 User Settings You have the possibility to configure the following user settings Pos 50 806 IHSE Konfiguration Benutzereinstellungen 480 xx User Data 7 mod_1309938316977_6 doc 53178 4 5 5 1 User Data New users and their user settings and permissions are set in this menu You have the following possibilities to access the menu You can select between the following settings Field Selection
12. 52550 4 3 6 1 Draco tera 288 Port FILTER 1 2 3 4 5 6 7 OK HS FAN TRAY OK HS FAN TRAY 8 Front View Draco tera 14 2011 10 11 1 Slot for power supply unit 1 2 Slot for fan tray 1 3 Slot for power supply unit 2 4 Slot for fan tray 2 5 Slot for I O boards 1 36 6 Slot for power supply unit 3 7 Slot for CPU board 8 Grounding Pos 12 806 IHSE Beschreibung Ger teansichten 480 xx Draco tera 160 Port 7 mod_1309934740805_6 doc 52568 4 3 6 2 Draco tera 160 Port FILTER 1 2 3 4 5 6 7 OK HS FAN TRAY OK HS FAN TRAY 8 Front View Description 2011 10 11 15 1 Slot for power supply unit 1 2 Slot for fan tray 1 3 Slot for power supply unit 2 4 Slot for fan tray 2 5 Slot for I O boards 1 20 6 Slot for power supply unit 3 7 Slot for CPU board 8 Grounding Pos 13 806 IHSE Beschreibung Ger teansichten 480 xx Draco tera 80 Port 7 mod_1309934775696_6 doc 52586 4 3 6 3 Draco tera 80 Port FILTER TOP 1 2 3 4 5 6 7 OK HS FAN TRAY OK HS FAN TRAY Front View 1 Slot for fan tray 2 Slot for power supply unit 1 3 Slot for I O boards 1 10 4 Slot for power supply unit 2 5 Slot for CPU board 6 Slot for air filter 7 Slot for fan tray 2 Pos 14 806 IHSE Beschreibung Ger teansichten 480 xx Draco tera 48 Port 7 mod_1311324635246_6 doc 54330
13. Delete Delete an existing user Apply Create a new user account Cancel Reject changes To configure a user access rights for CPUs proceed as follows 1 Select a user in the list User Data 2 By using the right mouse button once on a CPU in one of the respective access lists Full Access Video Access and No Access two lists for selection will appear in which the respective CPU can be moved and the access rights can be changed 3 Confirm the configuration with the button Apply Configuration 2011 10 11 77 To create a new user proceed as follows 1 Press the button New 2 Select a template of an existing user if applicable Choose template 3 Press the button OK 4 Set password 5 Set general access permissions 6 Set user permissions for CPU access paste function 7 Set user favorites for OSD access 8 Press the Button Apply to save the new user settings You can select between the following keyboard commands Function Keyboard Command Add CPU to list Full Access lt F gt Add CPU to list Video Access lt V gt Add CPU to list No Access lt N gt Pos 51 806 IHSE Konfiguration Extender Einstellungen 480 xx 7 mod_1309938366618_6 doc 53197 4 5 6 Extender Settings All extender units are managed in this menu This also contains the creation of new extender units and the deletion of existing extender units The extender unit describes the connection of an
14. 0x1B 1 Server identification 0X5B 1 Command 0x50 2 Total length of telegram 7 bytes binary 0x07 0x00 2 Total number of consoles binary 1 max CONs 0x01 0x00 for 1 console to 0x11F 0x00 for 287 consoles Example Connection of 43 with console 23 with 50 consoles in total 0x1B 0x5B 0x50 0x07 0x00 0x32 0x00 0x17 0x00 0x2B 0x00 Request of CON Input for CPU Output Bytes Description Coding 1 Control character 0x1B 1 Server identification 0X5B 1 Command 0x51 2 Total length of telegram 7 bytes binary 0x07 0x00 2 Requested output for CPU 0x01 0x00 for CPU 1 to 0x11F 0x00 for CPU 287 Example Request of CON input for CPU 23 0x1B 0x5B 0x51 0x07 0x00 0x17 0x00 Specifications 2011 10 11 129 Return of CON Input for CPU Output Bytes Description Coding 1 Control character 0x1B 1 Server identification 0X5D 1 Command 0x51 2 Total length of telegram 9 bytes binary 0x09 0x00 2 Requested output CPU 0x01 0x00 for CPU 1 to 0x11F 0x00 for CPU 287 2 Requested input console 0x01 0x00 for console 1 to 0x11F 0x00 for console 287 Example Request of console 23 for CPU 43 0x1B 0x5D 0x51 0x09 0x00 0x2B 0x00 0x17 0x00 Connection of CON Input with CPU Output Bytes Description Coding 1 Control character 0x1B 1 Server identification 0X5B 1 Command 0x52 2 Total length of telegram 9 bytes binary 0x09
15. 1 Select File gt Save As in the menu bar 2 Select the directory of the configuration on your storage medium where it has to be saved Configurations are always saved in a file with the ending dtc Draco tera 96 2011 10 11 Menu File Save As Pos 61 806 IHSE Konfiguration Speichern und Laden von Konfigurationen 480 xx Laden von Konfigurationen extern 7 mod_1309938925211_6 doc 53364 4 5 9 5 Loading of Configurations external Externally saved configurations are opened and activated in this menu You have the following possibilities to load configurations from files 1 Select File gt Open during offline mode and select the storage location of the configuration file that has to be opened 2 Open the configuration by pressing the button Open 3 Select File gt Upload to in the menu bar to transfer the opened configuration to the matrix Enter the necessary parameters 4 Select Switch gt Connect in the menu bar to make a connection between the matrix and the Java tool Enter the necessary parameters 5 Select Administration gt Activate Configuration and select the configuration that has to be activated 6 Confirm the process with the button Activate The opened configuration is activated now and can be used Configuration 2011 10 11 97 Menu File Open Pos 62 806 IHSE Konfiguration Export und Import von Listen 480 xx Export und Import von Listen 7 mod_13
16. 4 Draco tera 16 2011 10 11 3 6 4 Draco tera 48 Port FILTER TOP 1 2 3 4 5 6 7 OK HS FAN TRAY OK HS FAN TRAY Front View 1 Slot for fan tray 2 Slot for power supply unit 1 3 Slot for I O boards 1 10 4 Slot for power supply unit 2 5 Slot for CPU board 6 Slot for air filter 7 Slot for fan tray 2 Pos 15 806 IHSE Beschreibung Ger teansichten 480 xx Draco tera 8 Port 7 mod_1311324681380_6 doc 54348 4 3 6 5 Draco tera 8 Port Text Bild kommt Pos 16 806 IHSE Beschreibung Status UEB_Diagnose_und_Status 7 mod_1309935121461_6 doc 52641 4 Description 2011 10 11 17 3 7 Diagnostics and Status Pos 17 806 IHSE Beschreibung Diagnose LEDs 480 xx 7 mod_1309934983180_6 doc 52622 4 3 7 1 Status LEDs The Draco tera components are fitted with the following LEDs for overall status indication CPU Board Front View Draco tera 18 2011 10 11 Status LEDs on CPU board Pos LED Status Description White CPU board is in registration process Blue flashing Registration at the matrix is started Red flashing Registration in progress Green flashing Operating condition 1 Status 1 Green CPU board de registered White CPU board is in registration process Red flashing Registration at the matrix is started 2 Status 2 Off Operating condition Due to variations in LED type white might also appear as light purple
17. 42315 2 1 Specifications 2011 10 11 133 7 5 Connector Pinouts Pos 100 806 IHSE Technische Daten Pinbelegungen UEB_CPU Karte 7 mod_1309942897790_6 doc 53820 4 7 5 1 CPU Board Pos 101 806 IHSE Technische Daten Pinbelegungen Buchse DVI D Single Link 5 mod_1278578723073_6 doc 42333 1 Connector DVI D Single Link 1 8 C1 C2 C5 17 24 C3 C4 Pin Signal Pin Signal Pin Signal 1 T M D S data 2 9 T M D S data 1 17 T M D S data 0 2 T M D S data 2 10 T M D S data 1 18 T M D S data 0 3 T M D S data 2 GND 11 T M D S data 1 GND 19 T M D S data 0 GND 4 n c 12 n c 20 n c 5 n c 13 n c 21 n c 6 DDC Input SCL 14 5VDC high impedance 22 T M D S clock GND 7 DDC Output SDA 15 GND 23 T M D S clock 8 Internal use 16 Hot Plug recognition 24 T M D S clock C1 Internal use C3 Internal use C2 n c C5 GND C4 Internal use Pos 102 806 IHSE Technische Daten Pinbelegungen Buchse USB Typ A 5 mod_1278578771214_6 doc 42369 1 Connector USB Type A Picture Pin Signal Color 1 VCC 5VDC Red 2 Data White 3 Data Green 1 3 2 4 4 GND Black Pos 103 806 IHSE Technische Daten Pinbelegungen D Sub 9 Seriell 5 mod_1291128631437_6 doc 44882 1 Draco tera 134 2011 10 11 D Sub 9 Serial Picture Pin Signal Pin Signal
18. Field Selection Description activated CPU access is restricted according to the permissions in the ACL Access Control List User login is required Switching by keyboard Hot Keys requires a prior login Enable User ACL deactivated Function not active default activated CPU access is restricted according to the permissions in the respective Console ACL Access Control List No login required Enable Console ACL deactivated Function not active default activated Upon opening the OSD the console will be automatically disconnected from the current CPU Auto Disconnect deactivated Function not active default OSD Timeout 0 999 seconds Period of inactivity after which OSD will be closed automatically Select 0 seconds for no timeout default 0 seconds Auto Logout 0 999 minutes Period of inactivity after which a user is automatically logged out from the OSD at this console The timer is not active as long as the OSD is open Select 0 minutes for an immediate logout OSD Select Configuration gt Access in the main menu Configuration 2011 10 11 65 Menu Configuration Access You can select between the following buttons Button Function Cancel Reject changes Save Save changes Draco tera 66 2011 10 11 Java Tool Select System gt Access in the task area Menu System Access Pos 46 806 IHSE Konfiguration Systeme
19. IHSE GmbH Maybachstrasse 11 88094 Oberteuringen Germany info ihse de www ihse de Tel 49 7546 9248 0 Fax 49 7546 9248 48 User Manual Edition 2011 10 11 Draco tera Model 480 Series Draco tera 2 2011 10 11 Copyright 2011 All rights reserved This information may not be reproduced in any manner without the prior written consent of the manufacturer Information in this document is subject to change without notice Trademarks All trademark and trade names mentioned in this document are acknowledged to be the property of their respective owners Disclaimer While every precaution has been taken during preparation of this manual the manufacturer assumes no liability for errors or omissions Neither does the manufacturer assume any liability for damages resulting from the use of the information contained herein The manufacturer reserves the right to change specifications functions or circuitry of the product without notice The manufacturer cannot accept liability for damage due to misuse of the product or due to any other circumstances outside the manufacturer s control whether environmental or installation related The manufacturer shall not be liable for any loss damage or injury arising directly indirectly incidentally or consequently from the use of this product Contents 2011 10 11 3 Contents 1 About This Manual
20. Press keys simultaneously lt Key gt lt Key gt Press keys successively 2x lt Key gt Press key quickly twice in a row similar to a mouse double click Configuration 2011 10 11 41 The Hot Key sequence to enter Command Mode can be changed The following table lists the Hot Key Codes for the available key sequences Hot Key Code Hot Key 1 lt Left Ctrl gt lt Left Shift gt lt i gt 2 2x lt Scroll gt 3 2x lt Left Shift gt 4 2x lt Left Ctrl gt 5 2x lt Left Alt gt 6 2x lt Right Shift gt 7 2x lt Right Ctrl gt 8 2x lt Right Alt gt In a combined KVM matrix U Switch configuration choose different Hot Keys for the KVM matrix and the U Switch Pos 35 806 IHSE Konfiguration Ansteuerung 480 xx Ansteuerungsoptionen 7 mod_1309936958868_6 doc 52902 4 5 2 Control Options The Draco tera contains an internal CPU that allows you to control all functions from any console without the need for an external CPU or media control You have the following possibilities to access the Draco tera for configuration and operation via OSD via Java Tool via serial interface Pos 36 806 IHSE Konfiguration Ansteuerung 480 xx Ansteuerung via OSD 7 mod_1309937635540_6 doc 52920 4 Draco tera 42 2011 10 11 5 2 1 Control via OSD Via OSD On Screen Display you set the configuration of the Draco tera operating system The settings of the menu
21. Server identification 0X5D 1 Command 0x46 2 Total length of telegram 7 bytes binary 0x07 0x00 2 Input port whose signal is send to output port OutPort n 0x01 0x00 for 1 port to 0x120 0x00 for 288 ports Example Return input port 17 for all output ports 0x1B 0x5D 0x46 0x07 0x00 0x11 0x00 Request of CPU Input for CON Output Bytes Description Coding 1 Control character 0x1B 1 Server identification 0X5B 1 Command 0x47 2 Total length of telegram 7 bytes binary 0x07 0x00 2 Requested output console 0x01 0x00 for console 1 to 0x11F 0x00 for console 287 Example Request of CPU input for console 23 0x1B 0x5B 0x47 0x07 0x00 0x17 0x00 Draco tera 126 2011 10 11 Return of CPU Input for CON Output Bytes Description Coding 1 Control character 0x1B 1 Server identification 0X5D 1 Command 0x47 2 Total length of telegram 9 bytes binary 0x09 0x00 2 Requested output console 0x01 0x00 for console 1 to 0x11F 0x00 for console 287 2 Requested input CPU 0x01 0x00 for CPU 1 to 0x11F 0x00 for CPU 287 Example Return of CPU 34 for console 23 0x1B 0x5D 0x47 0x09 0x00 0x17 0x00 0x22 0x00 Connection of CPU Input with CON Output Bytes Description Coding 1 Control character 0x1B 1 Server identification 0X5B 1 Command 0x48 2 Total length of telegram 9 bytes binary 0x09 0x00 2 Requested console 0x01
22. 0x00 2 Requested output CPU 0x01 0x00 for CPU 1 to 0x11F 0x00 for CPU 287 2 Requested input console 0x01 0x00 for console 1 to 0x11F 0x00 for console 287 Example Connection of console 23 with CPU 43 0x1B 0x5B 0x52 0x09 0x00 0x2B 0x00 0x17 0x00 Draco tera 130 2011 10 11 Request CON Input for CPU Output with a fixed CPU number Bytes Description Coding 1 Control character 0x1B 1 Server identification 0X5B 1 Command 0x53 2 Total length of telegram 9 bytes binary 0x09 0x00 2 Total number of CPUs 0x01 0x00 for 1 CPU to 0x11F 0x00 for 159 CPUs 2 Requested output for CPU binary 1 max CPUs 0x01 0x00 for CPU 1 to 0x11F 0x00 for CPU 287 Example Request for CPU 43 with 50 CPUs in total 0x1B 0x5B 0x53 0x09 0x00 0x32 0x00 0x2B 0x00 Return of CON Input for CPU Output with a fixed CPU Number Bytes Description Coding 1 Control character 0x1B 1 Server identification 0X5D 1 Command 0x53 2 Total length of telegram 7 bytes binary 0x07 0x00 2 Total number of CPUs 0x01 0x00 for 1 CPU to 0x11F 0x00 for 287 CPUs Example Return of console 23 for CPU 43 with 50 CPUs in total 0x1B 0x5D 0x53 0x07 0x00 0x32 0x00 0x2B 0x00 0x17 0x00 Specifications 2011 10 11 131 Connection of CON Input with CPU Output with a fixed total CPU Number Bytes Description Coding 1 Control character 0x1B 1 Server identification 0X5B
23. 0x00 for console 1 to 0x11F 0x00 for console 287 2 Requested CPU 0x01 0x00 for CPU 1 to 0x11F 0x00 for CPU 287 Example Connection of CPU 43 with console 23 0x1B 0x5B 0x48 0x09 0x00 0x17 0x00 0x2B 0x00 Specifications 2011 10 11 127 Request of CPU Input for CON Output with a fixed Console Number Bytes Description Coding 1 Control character 0x1B 1 Server identification 0X5B 1 Command 0x49 2 Total length of telegram 9 bytes binary 0x09 0x00 2 Total number of consoles binary 1 max CONs 0x01 0x00 for 1 console to 0x11F 0x00 for 287 consoles 2 Requested consoles 0x01 0x00 for console 1 to 0x11F 0x00 for console 287 Example Request of CPU input for console 23 with 50 consoles in total 0x1B 0x5B 0x49 0x09 0x00 0x32 0x00 0x17 0x00 Return of CPU Input for CON Output with a fixed Console Number Bytes Description Coding 1 Control character 0x1B 1 Server identification 0X5D 1 Command 0x49 2 Total length of telegram 7 bytes binary 0x07 0x00 2 Total number of consoles binary 1 max CONs 0x01 0x00 for 1 console to 0x11F 0x00 for 287 consoles Example Return of CPU 43 for console 23 with 50 consoles in total 0x1B 0x5D 0x49 0x07 0x00 0x32 0x00 0x17 0x00 0x2B 0x00 Draco tera 128 2011 10 11 Connection of CPU Input with CON Output with a fixed Console Number Bytes Description Coding 1 Control character
24. Description Name Text User name case sensitive Password Text User password case sensitive Repeat Password Text Repeat user password case sensitive activated Access permission via HTTP HTTP deactivated Function not active default activated Access permission via FTP This setting is necessary for file access from the Java tool or any web browser FTP deactivated Function not active default activated Access permission via Telnet TEL deactivated Function not active default activated User has user rights Permission for crosspoint operations POW deactivated Function not active default activated Permission for system configuration and all switching operations User has administrator rights This setting is required for an online connection with the Java tool ADM deactivated Function not active default Configuration 2011 10 11 75 OSD Select Configuration gt User in the main menu Menu Configuration User You can select between the following buttons Button Function New Create a new user Edit Edit an existing user Delete Delete an existing user Cancel Reject changes Save Save changes Draco tera 76 2011 10 11 Java Tool Select User gt User Data in the task area Menu User User Data You can select between the following buttons Button Function New Open a new user configuration
25. Draco tera or Media Extender to connect to a source computer CPU DDC The Display Data Channel DDC is a serial communication interface between monitor and source computer CPU It allows a data exchange via monitor cable and an automatic installation and configuration of a monitor driver by the operating system Dual Access A system to operate a source computer CPU from two consoles Dual Head A system with two video connections Dual Link A DVI D interface for resolutions up to 2560x2048 by signal transmission of up to 330 MPixel s 24 bit DVI Digital video standard introduced by the Digital Display Working Group http www ddwg org Single Link and Dual Link standard are distinguished The signals have TMDS level Glossary 2011 10 11 145 Term Explanation DVI I A combined signal digital and analog that allows running a VGA monitor at a DVI I port in contrast to DVI D see DVI Fiber Single mode or multi mode fiber cables EGA The Enhanced Graphics Adapter EGA is an old analog graphic standard introduced by IBM in 1984 A D Sub 9 connector is used for connection Console Keyboard mouse and monitor CVBS The analog color video baseband signal CVBS is also called Composite Video and it is part of the PAL TV standard KVM Keyboard video and mouse Mini XLR Industrial standard for electrical plug connections 3 pole for the transmission of digital audio and control signals Mult
26. Java Tool Select System gt Switch in the task area Menu System Switch Pos 47 806 IHSE Konfiguration Systemeinstellung 480 xx Netzwerk Network 7 mod_1309938178305_6 doc 53122 4 5 4 5 Network The network configuration is set in this menu You have the following possibilities to access the menu You can select between the following settings Field Selection Description activated The network settings are automatically supplied by a DNS server default DHCP deactivated Function not active IP address Byte Input of the IP address in the form 192 168 1 1 if DHCP is not active Subnet Mask Byte Input of the subnet mask in the form 255 255 255 0 if DHCP is not active default 255 255 255 0 Configuration 2011 10 11 71 Field Selection Description Gateway Byte Input of the subnet mask in the form 192 168 1 1 if DHCP is not active Activate the modified network parameters by doing a restart Consult your system administrator before modifying the network parameters Otherwise unexpected results and failures can occur in combination with the network OSD Select Configuration gt Network in the main menu Menu Configuration Network You can select between the following buttons Button Function Cancel Reject changes Save Save changes Draco tera 72 2011 10 11 Java Tool Select System gt Network in the task area Menu System
27. KVM CON Unit Single Head Analog Audio 4x USB HID L477 1S4SD Draco tera KVM CPU Unit Single Head Digital Audio 4x USB HID R477 1S4SD Draco tera KVM CON Unit Single Head Digital Audio 4x USB HID Specifications 2011 10 11 119 Type Description L477 1STS Draco tera KVM CPU Unit Single Head 2x USB HID 4x USB 2 0 R477 1STS Draco tera KVM CON Unit Single Head 2x USB HID 4x USB 2 0 L477 2S4S Draco tera KVM CPU Unit Dual Head 4x USB HID R477 2S4S Draco tera KVM CON Unit Dual Head 4x USB HID L477 SHSV Draco tera KVM CPU Unit Single Head DVI I input VGA 2x USB HID KVM Extender with Fiber Connection Single Mode K474 Series Type Description L474 BSHS Draco tera KVM CPU Unit Single Head 2x USB HID R474 BSHS Draco tera KVM CON Unit Single Head 2x USB HID L474 BSHSV Draco tera KVM CPU Unit Single Head DVI I Input VGA 2x USB HID R474 BSHSV Draco tera KVM CON Unit Single Head IR receiver 2x USB HID Pos 95 806 IHSE Technische Daten Getestete Peripherie 480 xx USB 2 0 Extender 7 mod_1311332022526_6 doc 54422 4 7 3 2 USB 2 0 Extender USB 2 0 Extender with Cat X Connection K474 Series Type Description L474 BXTC Draco tera USB 2 0 CPU Unit 4x USB 2 0 R474 BXTC Draco tera USB 2 0 CON Unit 4x USB 2 0 USB 2 0 Extender with Fiber Connection Single Mode K474 Series Type Description L474 BXTS Draco tera USB 2 0 CPU Unit 4x USB 2 0 R474 BXTS D
28. active ID Real CPU Device Numerical value Initial value of the automatic ID for real CPUs default value 1000 Draco tera 62 2011 10 11 Field Selection Description ID Virtual CPU Device Numerical value Initial value of the automatic ID for virtual CPUs default value 2000 ID Real CON Device Numerical value Initial value of the automatic ID for real CONs default value 3000 ID Virtual CON Device Numerical value Initial value of the automatic ID for virtual CONs default value 4000 OSD Select Configuration gt System in the main menu Menu Configuration System You can select between the following buttons Button Function Cancel Reject changes Save Save changes Configuration 2011 10 11 63 Java Tool Select System gt Automatic ID in the task area Menu System Automatic ID Pos 45 806 IHSE Konfiguration Systemeinstellung 480 xx Zugang 7 mod_1309938080446_6 doc 53086 4 5 4 3 Access The access configuration is set in this menu You have the following possibilities to access the menu You can select between the following settings Field Selection Description activated The user has to login with a user name and a password once to enter OSD Thereafter the user remains logged in until he explicitly logs out or an auto logout is effected Enable User Login deactivated Function not active default Draco tera 64 2011 10 11
29. all consoles will receive the video signal of the new CPU You have the following possibilities to access the menu OSD Under development Java Tool Select Assignment gt Virtual to Real CPU in the task area Menu Assignment Virtual to Real CPU Draco tera 56 2011 10 11 For an assignment proceed as follows 1 Select a virtual CPU in the list Virtual CPU 2 Double click in the column Real CPU to get a list of all available real CPUs 3 Select a real CPU You can select between the following buttons Button Function Send Send assignments to the matrix Reload Reload changes By activating the function Auto Send in the left lower corner of the working area switching operations will be done immediately without confirmation by pressing the button Send The selection boxes in the column Real CPU contain a filter function for an easy selection of single consoles from a larger pool of consoles see Chapter 5 2 2 Page 47 The Java tool additionally offers the possibility to go directly from the menu Assignment to the menu Definition to check specific settings for the respective console or CPU Use the right mouse button to select the respective console or CPU and select Open CON Device or Open CPU Device Pos 41 806 IHSE Konfiguration Zuordnung 480 xx Echte Konsole zu virtueller Konsole 7 mod_1309937842805_6 doc 52994 4 5 3 2 Real Console to Virtual Console You can ass
30. are relevant for the CPU 5 To confirm the new CPU press the button Apply To access a new CPU via matrix an assignment of one or more CPU type extender units is required Proceed as follows 1 Select the new CPU in the list CPU Devices 2 Select one or more extenders in the list Extender available 3 Perform the assignment by pressing the button gt To assign all available extenders to the CPU press the button gt gt The assignments are displayed in the list Extender assigned 4 Confirm the assignment by pressing the button Apply To remove an extender assignment proceed as follows 1 Select a CPU in the list CPU Devices 2 Select one or more extenders in the list Extender assigned 3 Remove the assignment with the button lt To remove all existing assignments press the button lt lt 4 Confirm the removal with the button Apply Pos 53 806 IHSE Konfiguration Konsolen Einstellungen 480 xx Konsolen Einstellungen 7 mod_1309938518774_6 doc 53236 4 Draco tera 84 2011 10 11 5 8 Console Settings You have the possibility to perform the following console settings Pos 54 806 IHSE Konfiguration Konsolen Einstellungen 480 xx CON Devices 7 mod_1309938548274_6 doc 53254 4 5 8 1 CON Devices New CON devices are created in this menu including access rights and assignment to extenders You have the following possibilities to access the menu You can select between th
31. button and scroll mice Other USB HID devices The proprietary USB emulation also supports certain other USB HID devices such as specific touch screens graphic tablets barcode scanners or special keyboards Support cannot be guaranteed however for every USB HID device Only two USB HID devices are supported concurrently such as keyboard and mouse or keyboard and touch screen A hub is allowed but it does not increase the number of HID devices allowed To support other USB non HID devices such as scanners web cams or memory devices choose our devices with transparent USB support Pos 83 806 IHSE Technische Daten Schnittstellen RJ45 Netzwerk 7 mod_1309942049133_6 doc 53692 4 Specifications 2011 10 11 113 7 1 3 RJ45 Network The communication of the Cat X devices requires a 1000BASE T connection The cabling has to be done according to EIA TIA 568 B 1000BASE T with RJ45 connectors at both ends All of the four wire pairs are used in both directions The cabling is suitable for a full duplex operation For the cable connection to a source computer CPU a crossed network cable cross cable has to be used Pos 84 806 IHSE Technische Daten Schnittstellen RS 232 seriell 7 mod_1309942120758_6 doc 53710 4 7 1 4 RS 232 Serial The communication takes place with a transmission speed of up to 115 2 KBaud regardless of the file format The transmission takes place with eight data bits and a
32. environment this product may cause radio interference in which case the user may be required to take adequate measures Certificates 2011 10 11 143 10 2 North American Regulatory Compliance This equipment has been found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment Shielded cables must be used with this equipment to maintain compliance with radio frequency energy emission regulations and ensure a suitably high level of immunity to electromagnetic disturbances All power supplies are certified to the relevant major international safety standards Pos 127 806 IHSE Zertifikate ATB_WEEE 5 mod_1278579673292_6 doc 42704 2 1 10 3 WEEE The manufacturer complies with the EC Directive 2002 96 EG on the prevention of
33. gt Press keys simultaneously lt key gt lt key gt Press keys successively 2x lt key gt Press key 2x in quick succession cf mouse double click Menu item Description of a menu item in the software Menu item gt Menu item Select menu items successively Bold print Description of terms that are used in the device software Pos 3 806 IHSE Sicherheitshinweise 480_Sicherheitshinweise 7 mod_1310643167940_6 doc 54240 4 Draco tera 8 2011 10 11 2 Safety Instructions To ensure reliable and safe long term operation of your Draco tera please note the following guidelines Installation Only use the device according to this User Manual Otherwise the provided safety can be affected Only use in dry indoor environments The Draco tera and the power supply units can get warm Do not situate them in an enclosed space without any airflow Do not obscure ventilation holes Only use power supplies originally supplied with the product or manufacturer approved replacements Do not use a power supply if it appears to be defective or has a damaged chassis Connect all power supplies to grounded outlets In each case ensure that the ground connection is maintained from the outlet socket through to the power supply s AC power input Do not connect the link interface to any other equipment particularly network or telecommunications equipment Only connect devices to the seri
34. is not connected to a CPU you can establish an automatic connection to the next available CPU by hitting any key or mouse button CPU Auto Connect deactivated Function not active default CPU Timeout 0 999 minutes Period of inactivity after which a console will be automatically disconnected from its current CPU default value 0 minutes activated Activate request of K M control by keyboard event key will be lost Keyboard Connect deactivated Function not active default activated Activate request of K M control by mouse event Mouse Connect deactivated Function not active default Release Time 0 999 seconds Period of inactivity of a connected console after which K M control can be requested by other consoles connected to the CPU Note Set 0 for an immediate transfer in real time Only one console can have keyboard and mouse control at the same time The other consoles that are connected to the same CPU have a video only status default value 10 seconds If the options Keyboard Connect and or Mouse Connect are activated the condition Release Time will have to be met until a new user will gain control Configuration 2011 10 11 69 OSD Select Configuration gt Switch in the main menu Menu Configuration Switch You can select between the following buttons Button Function Cancel Reject changes Save Save changes Draco tera 70 2011 10 11
35. list Extender assigned 4 Confirm the assignment by pressing the button Apply To remove an extender assignment proceed as follows 1 Select the console in the list CON Devices to be modified 2 Select the extender s in the list Extender assigned to be removed 3 Remove the assignment with the button lt To remove all existing assignments press the button lt lt 4 Confirm the changes by pressing the button Apply Draco tera 88 2011 10 11 To configure the access rights of consoles to CPUs please proceed as follows 1 Select a console in the list CON Devices 2 Open the tab CPU Access Control 3 Assign new access rights by using the right mouse button or the respective keyboard commands cf below 4 Confirm the configuration by pressing the button Apply After creating a new user he is provided automatically with Full Access to all available CPUs You can select between the following keyboard commands Function Keyboard Command Add CPU to list Full Access lt F gt Add CPU to list Video Access lt V gt Add CPU to list No Access lt N gt Pos 55 806 IHSE Konfiguration Konsolen Einstellungen 480 xx Maus und Tastatur 7 mod_1309938591211_6 doc 53272 4 5 8 2 Mouse and Keyboard The OSD configuration for mouse and keyboard is made in this menu You have the following possibilities to access the menu You can select between the following settings Field Sele
36. only be performed in online mode that means an active network connection between the matrix and the Java Tool is needed Draco tera 110 2011 10 11 To set a KVM connection between a console and a CPU double click on the corresponding selection box within the CPU column and select the requested CPU green To set a video connection between a console and a CPU double click on the corresponding selection box within the CPU column and select the requested CPU orange CPUs whose respective console does not have access rights will not appear in the list You can use the following button to perform a switching operation Button Function Send Send effected switching operations to the matrix By activating the function Auto Send in the left lower corner of the working area switching operations will be done immediately without confirmation by pressing the button Send Additionally the menu offers the possibility to get from any console or CPU into the associated configuration menu in the task area 1 To get directly to Definition gt CON Devices use the right mouse button to click on the respective console in the list and select Open CON Device 2 To get directly to Definition gt CPU Devices use the right mouse button to click on the respective console in the list and select Open CPU Device Pos 74 806 IHSE Betrieb Serielle Schnittstellen 480 xx 7 mod_1309940914961_6 doc 53582 4 6 3 Seri
37. or light blue Description 2011 10 11 19 I O Board Cat X SFP Fiber SFP Coax Front View Draco tera 20 2011 10 11 Status LEDs at I O boards Pos LED Status Description Light blue I O board in boot process Red flashing I O board in registration process Green flashing Operating condition I O board registered at the matrix 1 Status 1 Green I O board de registered locking pin pulled out White I O board in boot process Blue I O board in registration process Blue flashing Operating condition communication active with CPU board active 2 Status 2 Red flashing I O board de registered locking pin pulled out Ports I O Board Cat X SFP Fiber SFP Coax Front View 1 Status LED 1 2 Status LED 2 Description 2011 10 11 21 Status LEDs at the ports of the I O boards Pos LED Status Description Off Port not activated Flashing Port activated no connection via interconnect cable 1 Link status green On Connection via interconnect cable ok data traffic active Off Port not activated Flashing Port activated no connection via interconnect cable 2 Link status orange On Connection via interconnect cable ok data traffic active Fan Tray OK HS FAN TRAY 1 2 3 Front View 1 Status LED 1 2 Status LED 1 3 Hot Swap LED Status LEDs of the fan trays Pos LED Status Description 1 Status 1 green On O
38. password for user authorization 4 Select Administration gt Activate Configuration in the task area and select the storage location that has been selected above 5 Use the button Activate to open the selected configuration within the matrix The connection and the open tab will be closed and the matrix will be restarted During the activation of a configuration the matrix is temporarily not available Configuration 2011 10 11 53 Configuration File The Java tool is equipped with an additional configuration file defaults cfg by default This file allows the user to set various configuration parameters of the Java tool The file can be opened and edited by standard text editor programs The following configuration parameters can be edited Parameter Description IP Default IP address of the matrix required for connection User Default user name required for connection sys dir Default directory for configuration files upd dir Default directory for update files dfw dir Default directory for the firmware status impexp dir Default directory for import and export files Pos 38 806 IHSE Konfiguration Ansteuerung 480 xx Ansteuerung via serieller Schnittstelle 7 mod_1309937747180_6 doc 52956 4 Draco tera 54 2011 10 11 5 2 3 Control via Serial Interface The Draco tera operating system offers various functions for an operation via serial interface see Chapter 7 4 Page 120 There are t
39. physical extender to the matrix Every extender board with a direct cable connection to the matrix is recognized as an extender unit Dual Head KVM extenders will be recognized as two independent extender units KVM Extenders automatically create extender units inside the matrix You have the following possibilities to access the menu Draco tera 78 2011 10 11 You can select between the following settings Field Selection Description ID Text Numerical value of the extender ID KVM Extenders ID is provided by extender unit Serial No and cannot be changed Name Text Name of the extender unit activated Create an extender unit with a fixed port assignment default Fixed deactivated Function not active Port 1 288 depending on the matrix Port number of the extender unit OSD Select Configuration gt EXT Units in the main menu Menu Configuration EXT Units Configuration 2011 10 11 79 You can select between the following buttons Button Function New Create a new extender unit Edit Edit an existing extender unit Delete Delete an existing extender unit Cancel Reject changes Save Save changes The settings for the tab OSD Data are described in Chapter 5 8 2 Page 88 Java Tool Select Definition gt EXT Units in the task area Menu Definition EXT Units You can select between the following buttons Button Function New Create a new
40. stop bit but without a parity bit Limited hardware handshake DSR is possible Pos 85 806 IHSE Technische Daten Schnittstellen RJ45 Ger tekommunikation 5 mod_1278578339308_6 doc 42186 3 1 7 1 5 RJ45 Interconnect The communication of the Cat X devices requires a 1000BASE T connection Connector wiring must comply with EIA TIA 568 B 1000BASE T with RJ45 connectors at both ends All four cable wire pairs are used Pos 86 806 IHSE Technische Daten Schnittstellen Glasfaser SFP Typ LC 5 mod_1278937700855_6 doc 43149 3 1 7 1 6 Fiber SFP Type LC Interconnect The communication of fiber devices is performed via Gigabit SFPs that have to be connected to suitable fibers fitted with connectors type LC see Chapter 7 2 2 Page 116 The correct function of the device can only be guaranteed with SFPs provided by the manufacturer SFP modules can be damaged by electrostatic discharge ESD Please consider ESD handling specifications Pos 87 806 IHSE Technische Daten Schnittstellen SDI Ger tekommunikation 7 mod_1309941998461_6 doc 53674 4 Draco tera 114 2011 10 11 7 1 7 SDI Interconnect The communication of the SDI devices requires a mini coax connection with mini BNC connectors or 3G SFPs with transmission speeds of 0 360 Gbit s SD SDI SMPTE 259M 1 485 Gbit s HD SDI SMPTE 292M and 2 970 Gbit s 3G SDI Pos 88 806 IHSE Technische Daten Verbindungskabel UEB_Verbindungs
41. tera 108 2011 10 11 Menu Switch The following information is shown in this menu Field Description CON device Assigned physical extender unit CON unit CON assigned Virtual CON Device that is assigned to the real CON device CPU connected Currently connected CPU device CON status Current connection status CON device EXT list List of all available physical extender units CON units CPU device Assigned physical extender unit CPU unit CPU assigned Real CPU device that is assigned to a virtual CPU device CON connected Currently connected CON device CPU status Current connection status CPU device EXT list List of all available physical extender units CPU units Operation 2011 10 11 109 You can select between the following switching functions Function Keyboard Command Set a video only connection lt Space gt Set a KVM connection lt Enter gt Set a KVM connection in private mode video sharing disabled lt Shift gt lt Enter gt Disconnect own CON device from CPU device lt Backspace gt Switching operations from the own CON device can only be done to CPU devices that are available in the list CPU Devices Java Tool Select Switch gt Switch Console to CPU in the task area Menu Switch Switch Console to CPU All connected consoles and the associated CPU connections are shown in columns in the working area in this menu Switching operations can
42. the main menu Menu Configuration CPU Devices You can select between the following buttons Button Function New R Create a new real CPU device New V Create a new virtual CPU device Edit Edit an existing CPU device Delete Delete an existing CPU device Cancel Reject changes Save Save changes Draco tera 82 2011 10 11 Java Tool Select Definition gt CPU Devices in the task area Menu Definition CPU Devices You can select between the following buttons Button Function New Open a new CPU Device Delete Delete a new CPU Device Apply Confirm a created CPU Device Cancel Reject changes gt Assign selected extender units gt gt Assign all available extender units lt Remove the selected extender units lt lt Remove all extender units Configuration 2011 10 11 83 You can select between the following keyboard commands Function Keyboard Command Change assignment number of the EXT unit upwards lt gt Change assignment number of the EXT unit downwards lt gt To create a new CPU device proceed as follows 1 Press the button New 2 Select if a real CPU Create a real CPU or a virtual CPU Create a virtual CPU should be created or a template of an existing CPU should be used Choose template A template can only be used if there is at least one existing CPU device 3 Press the button OK 4 Determine all parameters that
43. to 0x7F are provided with an offset by 0x80 e g 0000011 gt 0x83 c ASCII data gt 0x20 to 0x7E are transmitted unencryptedly Specifications 2011 10 11 121 Special characters ACK 0x06 NAK 0x15 STX 0x02 ETX 0x03 CR 0x0D ESC 0x1B HTAB 0x09 LF 0x0A Sequence of a Data Communication Draco tera Matrix Control CPU Sending of a command Acquiring of a command processing of a command blocking of further commands a Errors occurred lt NAK gt b No errors lt ACK gt lt ECHO gt c Optional Reply telegram with data a Repeat telegram b Next command c Receive and process the repeat telegram The serial interface can be blocked while OSD has been opened Pos 98 806 IHSE Technische Daten Serielle Ausstattung Telegramme der Schaltfunktionen 7 mod_1309942765508_6 doc 53802 4 Draco tera 122 2011 10 11 7 4 1 Telegrams of the Switching Functions Request of Input Port for Output Port Bytes Description Coding 1 Control character 0x1B 1 Server identification 0X5B 1 Command 0x42 2 Total length of telegram 7 bytes binary 0x07 0x00 2 Requested output port binary 1 max ports 0x01 0x00 for port 1 to 0x120 0x00 for port 288 Example Request of input port for output port 160 0x1B 0x5B 0x42 0x07 0x00 0xA0 0x00 Return of Input Port for Output Port Bytes Description Coding 1 Control character 0x1B 1 Ser
44. 07415_6 doc 54133 4 8 5 Network Error Diagnosis Possible Reason Measure Network settings are not assumed after editing Restart of the matrix not yet completed Do a restart Pos 122 806 IHSE Hilfe im Problemfall St rung an der Matrix 480 xx 7 mod_1309944331383_6 doc 54040 4 8 6 Failure at the Matrix Diagnosis Possible Reason Measure Serial control impossible or only restrictedly possible Different Baud rate of CPU and matrix Adapt Baud rate in the matrix and in the CPU see Chapter 5 3 2 Page 56 Serial control via RJ45 port not possible Wrong network cable Use a crossed network cable Port definitions as USB 2 0 invalid Restart of the matrix not yet completed Do a restart Pos 123 806 IHSE Hilfe im Problemfall Bildausfall 480 xx 7 mod_1309944397665_6 doc 54058 4 Draco tera 140 2011 10 11 8 7 Blank Screen 1 2 3 1 2 3 3 Rear View Front View Diagnosis Possible Reason Measure Switching to a CPU Port without active Source computer CPU Switching to a CPU Port with an active source computer CPU Monitors remains dark after switching operation Connection of a console with a CON port or connection of a CPU to a CPU port not established correctly Check connections regarding CON and CPU ports at the matrix LED 1 on or LED 2 off Connections CON unit matrix and CPU unit Check connecting cabl
45. 09939181868_6 doc 53390 4 5 10 Export and Import Options The Draco tera offers the possibility to read out available configuration lists extender CPUs consoles and users for exporting and importing again via Java tool You have the following possibilities to handle configuration lists Exported configuration lists are always saved in csv format that allows offline editing with common spreadsheet applications You have the following possibilities to export or import configuration lists Pos 63 806 IHSE Konfiguration Export und Import von Listen 480 xx Export von Listen 7 mod_1309939231696_6 doc 53408 4 Draco tera 98 2011 10 11 5 10 1 Export Options Configuration lists are exported in this menu To export proceed as follows 1 Select File gt Export in the menu bar 2 After opening the menu select the list to export Extender CPU Console or User 3 Select the storage location for the export file 4 Confirm the export with the button Finish Menu File Export Pos 64 806 IHSE Konfiguration Export und Import von Listen 480 xx Import von Listen 7 mod_1309939264649_6 doc 53426 4 Configuration 2011 10 11 99 5 10 2 Import Options Configuration lists are imported in this menu To import proceed as follows 1 Select File gt Import in the menu bar 2 After opening the menu select the list to import Extender CPU Console or User 3 Select the director
46. 806 IHSE Hilfe im Problemfall Bildst rung 480 xx 7 mod_1309944461727_6 doc 54076 4 8 2 Video Interference Diagnosis Possible Reason Measure Opening the OSD not possible No OSD jumper set Set jumper 11 on the CON unit Incorrect video display Cable connection disturbed Check the connection length and quality of the interconnect cable to the units Pos 119 806 IHSE Hilfe im Problemfall L fterst rung 480 xx 7 mod_1309944511868_6 doc 54095 4 8 3 Malfunction of Fans Diagnosis Possible Reason Measure Fans only run under full load Communication to fan tray is disturbed Removal and und reinstallation of the fan tray Fans do not run LED OK on Fans defective Contact your dialer Fans do not run LED OK off Power supply Check power supply and power connection Pos 120 806 IHSE Hilfe im Problemfall St rung der Netzteile 480 xx 7 mod_1309944565727_6 doc 54114 4 Troubleshooting 2011 10 11 139 8 4 Malfunction of Power Supply Units Diagnosis Possible Reason Measure Power supply units not locked correctly Check lock and plug in of the power supply units No power supply available Check if cables for the power supply are connected correctly Matrix cannot be started Power supply units are not switched on Check slide to switch on the power supply units Pos 121 806 IHSE Hilfe im Problemfall Netzwerkst rung 480 xx 7 mod_13099446
47. 933105946_6 doc 52477 4 3 2 Access Options You have the following options to access the Draco tera for configuration and operation Access Option Symbol OSD Java tool Serial interface Pos 7 806 IHSE Beschreibung System bersicht 480 xx 7 mod_1309933171196_6 doc 52495 4 4 3 Draco tera 10 2011 10 11 3 3 System Overview A Draco tera matrix system consists of a Draco tera matrix and for KVM applications of one or more CPU Units CON Units The Draco tera matrix is connected to the CPU Units CON Units by interconnect cables or connected directly to the video devices where used as a video matrix The CPU units are connected directly to the sources computer CPU by the provided cables Monitor s keyboard and mouse are connected to the CON units The communication between the Draco tera matrix and the CPU Units CON Units takes place over the respective interconnect cables 1 2 3 5 3 6 4 System Overview exemplary 1 Source computer CPU 2 CPU Units 3 Interconnect cable 4 Draco tera matrix 5 CON Units 6 Console monitor keyboard mouse See Chapter 4 3 Page 34 for installation examples Pos 8 806 IHSE Beschreibung Ger tetypen 480 xx 7 mod_1309934329227_6 doc 52513 4 Description 2011 10 11 11 3 4 Product Range Part No Description K480 288 Draco tera matrix with 288 ports empty free configuration K480 160 Draco tera matr
48. 939496086_6 doc 53444 4 The Draco tera can be operated in three different ways 1 Direct Switching via a keyboard connected to a CON port and the Hot Keys by a macro keyboard connected to a console port 2 OSD via keyboard mouse directly connected to the CPU board of the matrix via keyboard mouse connected to a CON Unit and the OSD 3 External Switching Commands via an external computer via Java tool network connection required via a media control network or serial connection required Pos 68 806 IHSE Betrieb Bedienung ber HotKeys 480 xx UEB_Bedienung_ ber_Hotkeys 7 mod_1309939558243_6 doc 53464 4 Operation 2011 10 11 105 6 1 Operation via Hot Keys Pos 69 806 IHSE Betrieb Bedienung ber HotKeys 480 xx Direktumschaltung 7 mod_1309940339211_6 doc 53490 4 6 1 1 Direct Switching The direct switching by Hot Keys on a keyboard is the fastest possibility for a user to switch at his console between different CPUs There is a possibility to switch video keyboard and mouse or only video Direct Switching of Video Keyboard and Mouse 1 Start Command Mode with the Hot Key For control the LEDs Shift and Scroll flash at the keyboard if Command Mode is activated 2 Enter the index number of the new CPU from the list of favorites and confirm with lt Enter gt At the same time the Command Mode is closed and the console is connected to t
49. Configuration are described below All other menus are described in later chapters You have the following possibilities to enter the OSD of the Draco tera via keyboard connected to the CPU board via keyboard connected to a CON unit of an extender Entering OSD 1 Start Command Mode with the Hot Key see Chapter 5 1 Page 40 2 Press lt o gt to open OSD You will see a list of all available CPUs as a start menu 3 Press lt Esc gt to enter the main menu Leaving OSD Press lt Shift gt lt Esc gt simultaneously The OSD will be closed without any further changes and the currently active CPU connection will be displayed Configuration 2011 10 11 43 Menu Structure Example View The general layout of the OSD is structured into three areas Upper status area topmost two text lines Working area Lower status area lowest two text lines Keyboard control You can select between the following keyboard commands Function Keyboard Command Left cursor only within an input field or a switching screen lt Cursor Left gt Right Cursor only within an input field or a switching screen lt Cursor Right gt In input fields Line up with wrap around In menus Line up without wrap around lt Cursor Up gt Draco tera 44 2011 10 11 Function Keyboard Command In input fields Line down with wrap around In menus Line do
50. Display Y Yes or N No IP Address Information about the IP address as provided manually or via DHCP Subnet Mask Information about the subnet mask as provided manually or via DHCP Gateway Information about the gateway address as provided manually or via DHCP MAC ID Information about the MAC address in the matrix Description 2011 10 11 27 OSD Select Status gt Network in the main menu Menu Status Network Draco tera 28 2011 10 11 Java Tool 1 Select Status gt Matrix View in the task area Menu Status Matrix View 2 Use the left mouse button to click on the network port of the CPU board The corresponding network status will be shown in the right part of the working area Pos 21 806 IHSE Beschreibung Status Firmware Status 480 xx 7 mod_1309935560836_6 doc 52699 33 4 Description 2011 10 11 29 3 7 5 Firmware Status Matrix The current firmware status of the installed boards is shown in this menu You have the following possibilities to access the menu The following information is shown in this menu Field Description Name Description of the modules Type Type number Ports Number of ports Version Complete description of the firmware version Date Date of the firmware version Status Module status OSD Select Status gt Firmware in the main menu Menu Status Firmware Draco tera 30 2011 10 11 Java Tool 1 Selec
51. GBIC receiver dual unidirectional for the use with Draco tera HD SDI 480 RS3G Single mode GBIC receiver dual unidirectional for the use with Draco tera 3G SDI 480 RBHD Koax GBIC receiver dual unidirectional for the use with Draco tera HD SDI 480 RB3G Koax GBIC receiver dual unidirectional for the use with Draco tera 3G SDI 480 FAN160 Draco tera 288 160 fan tray spare part 480 FAN80 Draco tera 80 fan tray spare part 480 FAN48 Draco tera 48 fan tray spare part 480 RED160 Draco tera 160 plug in power supply unit spare part or redundancy 480 RED80 Draco tera 80 plug in power supply unit spare part or redundancy 480 RED48 Draco tera 48 plug in power supply unit spare part or redundancy 480 RED288 Draco tera 288 plug in power supply unit spare part or redundancy 480 SLTR160 Draco tera 160 filter pads as consumable supply 480 SLTR80 Draco tera 80 filter pads as consumable supply 480 SLTR48 Draco tera 48 filter pads as consumable supply You can find appropriate extenders or other components in Chapter 7 3 Page 117 Pos 10 806 IHSE Beschreibung Ger teansichten 480_Ger teansichten 7 mod_1310643525018_6 doc 54278 4 Description 2011 10 11 13 3 6 Device Views The following views of the Draco tera matrix illustrate the various available chassis types Pos 11 806 IHSE Beschreibung Ger teansichten 480 xx Draco tera 288 Port 7 mod_1309934693586_6 doc
52. Port 16 3 7 Diagnostics and Status 17 3 7 1 Status LEDs 17 3 7 2 Port Status 23 3 7 3 Extender OSD 25 3 7 4 Network Status 26 3 7 5 Firmware Status Matrix 29 3 7 6 Firmware Status Extender 31 3 8 Trace Function 32 4 Installation 33 4 1 Package Contents 33 4 2 System Setup 33 4 3 Example Applications 34 4 3 1 KVM Matrix 35 Draco tera 4 2011 10 11 4 3 2 Video Matrix 36 4 3 3 Video Editing 36 4 3 4 Parallel Operation Stacking 37 4 3 5 Cascading
53. aco tera matrix 5 CON unit 6 Console monitor keyboard mouse If you have a Single Head console you can also get access to a Dual Head or Quad Head console for example However control is only possible at monitor 1 Any signal source can be switched to any number of monitors that will show the video signal at the same time In addition to that even optional audio can be switched Pos 29 806 IHSE Installation Installationsbeispiele 480 xx Videomatrix 7 mod_1309936380821_6 doc 52828 4 Draco tera 36 2011 10 11 4 3 2 Video Matrix If you use the Draco tera as a video matrix up to 288 input ports can be switched to up to 288 output ports depending on components and equipment 1 2 2 3 4 Video Matrix 1 Video source e g SDI camera 2 Interconnect cable 3 Draco tera matrix 4 Video sink e g monitor Pos 30 806 IHSE Installation Installationsbeispiele 480 xx Videobearbeitung 7 mod_1311326562605_6 doc 54366 4 4 3 3 Video Editing Text kommt Pos 31 806 IHSE Installation Installationsbeispiele 480 xx Parallelbetrieb Stacking 7 mod_1309936438040_6 doc 52846 4 Installation 2011 10 11 37 4 3 4 Parallel Operation Stacking If you have special configurations especially at installations with several monitors per work station or additional support of USB 2 0 transmission paths the number of connectable CPUs and consoles can be increased by a parallel operati
54. al Interface The Draco tera offers the possibility to switch via a serial interface RS232 Detailed information for the serial interface and the corresponding switching commands can be found in Chapter 7 4 Page 120 Pos 75 806 IHSE Betrieb EIn und Ausschaltfunktionen UEB_Ein _und_Ausschaltfunktionen 7 mod_1309940964258_6 doc 53601 4 Operation 2011 10 11 111 6 4 Power On and Power Down Functions Pos 76 806 IHSE Betrieb EIn und Ausschaltfunktionen 480 xx Neustart 7 mod_1309941015165_6 doc 53620 4 6 4 1 Restart You have the following possibilities to perform a restart OSD 1 Select Configuration gt Restart Matrix or Restart IO Board in the main menu to restart either the matrix or the I O boards 2 Confirm the selection with button YES The Draco tera will be restarted with the current settings Java Tool Select Switch gt Restart Matrix in the menu bar The Draco tera will be restarted with the current settings Pos 77 806 IHSE Betrieb EIn und Ausschaltfunktionen 480 xx Reset 7 mod_1309941081774_6 doc 53638 4 6 4 2 Reset You have the following possibilities to perform a reset of the system If a firmware update has been done since the delivery the matrix will be set to the state defined there OSD 1 Select Configuration gt Reset Matrix in the main menu 2 Confirm the selection with the button YES The Draco tera will be reset to factory sett
55. al interface that are sufficiently secured against short circuit currents and false voltages at the serial interface Take any required ESD precautions Repair Do not attempt to open or repair a power supply unit Do not attempt to open or repair the Draco tera There are no user serviceable parts inside Please contact your dealer or manufacturer if there is a fault Pos 4 806 IHSE Beschreibung UEB_Beschreibung 5 mod_1278573379151_6 doc 41546 1 1 Description 2011 10 11 9 3 Description Pos 5 806 IHSE Beschreibung Verwendungszweck 480 xx 7 mod_1309932919008_6 doc 52458 4 3 1 Application The Draco tera matrix is used to establish connections from consoles monitor keyboard mouse and other peripheral devices to various sources computer CPU In a maximum configuration up to 288 independent ports can be defined and switched either as a console or a CPU The Draco tera matrix is mainly specified for the use with extenders that are able to transmit video KVM and USB 2 0 signals But it can be also run as a video matrix The connection between the matrix and the peripheral devices such as KVM extenders or video sources can be made by Cat X fiber or coaxial cables The matrix serves as a repeater Thus the matrix can be run at a maximum distance of 10 km from the consoles and 10 km from the sources Pos 6 806 IHSE Beschreibung Zugriffsm glichkeiten 480 xx 7 mod_1309
56. ation connection to and between extension modules in a network environment User ACL User Access Control List is a list that shows the respective switching rights fort he various users Video Sharing Matrix function that allows switching from the own console to any CPU with video Ende der Liste f r Textmarke Inhalt
57. button once or twice to click on the header of the column that is sorted until the displayed arrow will disappear Draco tera 52 2011 10 11 Filter Function Lists and tables in the Java Tool offer a filter function that allows a fast and smooth search inside 1 To activate a filter use the right mouse button to click on the header of the column that has to be filtered and select Set Filter 2 Write directly the word or part of a word that has to be filtered into the header The filter results are shown immediately 3 To delete a filter use the right mouse button to click on the header of the column that has to be filtered and select Clear Filter An active filter is indicated by an asterix in the header The filter function is based on the functional principle of common web search engines Configuration in the Java Tool Configuration and system settings via Java Tool can only be changed in offline mode without a direct connection between matrix and Java Tool To activate a configuration in the matrix please proceed as follows 1 Select File gt Upload to in the menu bar 2 Enter the IP address of the matrix see Chapter 5 2 3 Page 54 and the name and password of the user authorization and select the storage location of the new configuration default or config01 08 in the menu Select Configuration 3 Select Switch gt Connect in the menu bar and enter the IP address of the matrix and the name and
58. cal HID devices include keyboards mice graphics tablets and touch screens Storage video and audio devices are not HID VGA Video Graphics Array VGA is a computer graphics standard with a typical resolution of 640x480 pixels and up to 262 144 colors It can be seen as a follower of the graphics standards MDA CGA and EGA Pos 130 806 IHSE Glossar 480 xx 7 mod_1309944815290_6 doc 54151 4 Glossary 2011 10 11 147 11 1 Matrix specific Glossary Term Explanation Auto Disconnect Matrix function that allows an automatic disconnect between a console and a CPU if OSD is opened via this console Auto Logout Matrix function that describes the duration of inactivity after the user haws been logged out from the OSD at this console CON Device Logical term that summarizes several physical extenders to switch more complex console systems via matrix CON Timeout Matrix function that allows an automatic disconnect of the own console from the connected CPU after a predefined time Console ACL Console Access Control List is a list that shows the respective switching rights for the various consoles CPU Auto Connect Matrix function that allows an automatic connection establishment between the own console and a random CPU that is available CPU Device Logical term that summarizes several physical extenders to switch more complex CPU systems via matrix CPU Timeout Matrix function that allows the user to di
59. ction Description Hor Speed 1 x 1 9 Adjustment of the horizontal mouse speed 1 slow 9 fast default value 4 Ver Speed 1 x 1 9 Adjustment of the vertical mouse speed 1 slow 9 fast default value 5 Double Click 100 800 Adjustment of the time slot for a double click default value 200 ms Keyboard layout Region Set the OSD keyboard layout according to the used keyboard default German DE Configuration 2011 10 11 89 Field Selection Description Video Mode Variable or specific resolution Resolution that is used when opening OSD The mouse and keyboard settings are console specific and can be separately set for every console OSD Select Configuration gt EXT Units in the main menu Menu Configuration EXT Units You can select between the following buttons Button Function Cancel Reject changes Save Save changes Draco tera 90 2011 10 11 Java Tool Select Definition gt EXT Units in the task area Mouse and keyboard settings are made in the tab OSD Data Menu Definition EXT Units Pos 56 806 IHSE Konfiguration Speichern und Laden von Konfigurationen 480 xx Speichern und Laden von Konfigurationen 7 mod_1309938757899_6 doc 53292 4 5 9 Saving and Loading of Configurations You have the possibility to set the following administration of configurations Pos 57 806 IHSE Konfiguration Speichern und Laden von Konfiguration
60. ctivated 2 Press the key lt Left Shift gt and hold it down You can now enter the index numbers of the various CPUs from the list of favorites with the keyboard and immediately switch to the video signal of the respective CPU after entering the index number 3 Leave Scan Mode by pressing lt Left Shift gt lt Esc gt Optimal results can be achieved by the use of as identical resolutions as possible This contributes to a smooth and delay less function of the scan mode Pos 71 806 IHSE Betrieb Bedienung ber HotKeys 480 xx Adressierung von Main Matrix und Sub Matrix 7 mod_1309940780680_6 doc 53526 4 6 1 3 Addressing of Main and Sub Matrices The Draco tera can be cascaded in two steps You can optionally send the commands including opening the OSD to the main or the sub matrix Whenever command mode is activated you can select by a lt m gt or a lt s gt if all of the following commands should be handled in the main or in the sub matrix OSD Access OSD access to the main matrix lt Left Shift gt lt Left Shift gt lt m gt optional lt o gt OSD access to the sub matrix lt Left Shift gt lt Left Shift gt lt s gt lt o gt Example Switching to the CPU port 23 of the sub matrix 1 Switching to the CPU Port e g 12 of the master matrix that have the connection to the sub matrix lt Left Shift gt lt Left Shift gt lt m gt optional lt 1 gt lt 2 gt lt Ent
61. e following settings Field Selection Description ID Text ID of the CON unit see Chapter 5 4 2 Page 61 Name Text Name of the CON Device activated Create new CON device as a virtual one Virtual Device deactivated Function not active default activated Allow user login at this CON device Allow Login deactivated Function not active default activated Force user login at this CON device Force Login deactivated Function not active default activated If there is a loss of connection the last picture shown will be still displayed and is surrounded by an orange frame If you switch to a CPU without video signal a blank screen will appear surrounded by an orange frame LOS Frame deactivated Function not active default Configuration 2011 10 11 85 OSD Select Configuration gt CON Devices in the main menu Menu Configuration CON Devices You can select between the following buttons Button Function New R Create a real console New V Create a virtual console Edit Edit an existing console Delete Delete an existing console Cancel Reject changes Save Save changes Java Tool Select Definition gt CON Devices in the task area Draco tera 86 2011 10 11 Menu Configuration CON Devices You can select between the following buttons Button Function New Open a new CON device Delete Delete a new CON device Appl
62. elegrams for Switching single or all connections available both unidirectional and bidirectional In addition to that there are telegrams for an overall definition of the total switching status and for saving and loading such switching states By request the Draco tera optionally provides an echo of all effected switching operations via serial interface or network interface That is why you have the possibility to track the current configurations of the matrix at any time and so update your own applications As an additional application you can switch parallely Draco tera clones as slaves Stacking via serial network interface Pos 39 806 IHSE Konfiguration Zuordnung 480 xx Zuordnung 7 mod_1309937797383_6 doc 52976 4 5 3 Assignment The Draco tera offers the possibility of a console specific or a CPU specific assignment The first possibility is to assign virtual CPUs to real CPUs The second possibility is to assign real consoles to virtual consoles Pos 40 806 IHSE Konfiguration Zuordnung 480 xx Virtuelle CPU zu realer CPU 7 mod_1309937891305_6 doc 53012 4 Configuration 2011 10 11 55 5 3 1 Virtual CPU to real CPU You can assign virtual to real CPUs in this menu With this function the effort for switching several consoles to the same CPU can be reduced If there a several consoles connected to a virtual CPU that is assigned to a real CPU you will only have to chance the real CPU once and
63. en 480 xx Zwischenspeichern von Konfigurationen 7 mod_1309945736118_6 doc 54172 4 Configuration 2011 10 11 91 5 9 1 Active Configuration You have the following possibility to access the menu Select Configuration gt Save in the main menu By selecting this menu item the active configuration of the matrix is saved to the permanent matrix memory By default the last configuration that has been saved in this way will be restored after a restart of the matrix Changing configurations or saving them blocks the matrix memory and leads to a freeze of all OSD menus for a few seconds The switching connections are not affected by this freeze If you select Auto Save within the system settings an additional automatic saving of the configuration will be performed periodically see Chapter 5 3 2 Page 56 Pos 58 806 IHSE Konfiguration Speichern und Laden von Konfigurationen 480 xx Speichern von Konfigurationen intern 7 mod_1309938789321_6 doc 53310 4 5 9 2 Saving of Configurations internal In this menu the current matrix configuration to predefined storage locations is saved However it does not replace the buffering of configuration see Chapter 5 9 1 Page 91 You have the following possibilities to access the menu In Active the name and detailed information of the current configuration are shown This configuration can be saved now In Default and File 1 to File 8 the name and the detailed in
64. equest of input port for output port 25 with a total port number of 160 0x1B 0x5B 0x44 0x09 0x00 0xA0 0x00 0x19 0x00 Draco tera 124 2011 10 11 Return of Input Port for Output Port with a fixed Port Number Bytes Description Coding 1 Control character 0x1B 1 Server identification 0X5D 1 Command 0x44 2 Total length of telegram 7 bytes binary 0x07 0x00 2 Number of output ports binary 1 max 288 ports 0x01 0x00 for 1 port to 0x11F 0x00 for 287 ports Example Return of input port 17 for output port 25 with a total port number of 160 0x1B 0x5D 0x44 0x09 0x00 0xA0 0x00 0x19 0x00 0x11 0x00 Connection of Input Port with Output Port with a fixed total Port Number Bytes Description Coding 1 Control character 0x1B 1 Server identification 0X5B 1 Command 0x45 2 Total length of telegram 7 bytes binary 0x07 0x00 2 Number of output ports binary 1 max 287 ports 0x01 0x00 for 1 ports to 0x11F 0x00 for 287 ports Example Connection of input port 17 with output port 25 with a total port number of 160 0x1B 0x5B 0x45 0x07 0x00 0xA0 0x00 0x19 0x00 0x11 0x00 Specifications 2011 10 11 125 Request of Switching Matrix Bytes Description Coding 1 Control character 0x1B 1 Server identification 0X5B 1 Command 0x46 Return of the Switching Matrix Input Port for all Output Ports Bytes Description Coding 1 Control character 0x1B 1
65. er gt 2 Switching to the CPU Port 23 of the sub matrix lt Left Shift gt lt Left Shift gt lt s gt lt 2 gt lt 3 gt lt Enter gt Operation 2011 10 11 107 The selected main matrix sub matrix mode is permanently activated until the other mode will be manually activated This means that if you select lt s gt for example all prospective commands will be sent to the slave but not if the Command Mode is left in the meantime Pos 72 806 IHSE Betrieb Bedienung ber HotKeys 480 xx Funktionstasten lt F1 gt lt F12 gt 7 mod_1309940812665_6 doc 53544 4 6 1 4 Function Keys lt F1 gt lt F12 gt In Command Mode you can retrieve the macros 1 12 with the function keys lt F1 gt lt F12 gt of the connected standard keyboard instead of the special macro keyboard The deposited command sequence for the appropriate function key is executed and Command Mode is left immediately By a prefixed lt s gt or lt S gt and lt m gt or lt M gt you can select if the command sequence should be executed for the master or the slave The chosen control level remains selected until the other one will be selected but not if Command Mode is left in the meantime Pos 73 806 IHSE Betrieb Switch 480 xx 7 mod_1309940863555_6 doc 53563 4 6 2 KVM Switching You have the following possibilities to perform switching operation with the Draco tera OSD Select Switch in the main menu Draco
66. erican Regulatory Compliance 143 10 3 WEEE 143 10 4 RoHS 143 11 Glossary 144 11 1 Matrix specific Glossary 147 Pos 1 806 IHSE Zu diesem Handbuch ATB_Zu diesem Handbuch 5 mod_1278573163276_6 doc 41510 1222 1 About This Manual 2011 10 11 7 1 About This Manual 1 1 Scope This manual describes how to install your Draco tera how to operate it and how to perform trouble shooting 1 2 Validity This manual is valid for all devices listed on the front page The product code is printed on the base of the devices 1 3 Cautions and Notes The following symbols are used in this manual This symbol indicates an important operating instruction that should be followed to avoid any potential damage to hardware or property loss of data or personal injury This symbol indicates important information to help you make the best use of this product Pos 2 806 IHSE Zu diesem Handbuch ATB_Schreibweisen 7 mod_1309932297321_6 doc 52440 4 1 1 Spellings You can find the following spellings in the manual Spelling Description lt key gt Description of a key on the keyboard lt key gt lt key
67. es and connectors No cable cable break CPU CON unit offline CPU CON unit connected to the wrong port LED 3 off Power supply Check power supply units and the connection to the power network Pos 124 806 IHSE Technische Unterst tzung ATB_Technische Unterst tzung 5 mod_1278579487089_6 doc 42650 122 1 Technical Support 2011 10 11 141 9 Technical Support Prior to contacting support please ensure you have read this manual and then installed and set up your Draco tera as recommended 9 1 Support Checklist To efficiently handle your request it is necessary to complete our checklist for support and problem cases Download Keep the following information available before you call Company name phone number and email Type and serial number of the device see bottom of device Date and number of sales receipt name of dealer if necessary Issue date of the existing manual Nature circumstances and duration of the problem Involved components such as graphic source CPU OS graphic card monitor USB HID USB 2 0 devices interconnect cable including manufacturer and model number Results from any testing you have done 9 2 Shipping Checklist 1 To return your device contact your dealer to obtain a RMA number Return Material Authorization 2 Package your devices carefully preferably using the original box Add all pieces which you received originally
68. extender unit Delete Delete an existing unit Apply Confirm changes of an extender unit Cancel Reject changes Draco tera 80 2011 10 11 1 To create a new extender unit press the button New 2 Select if a template of an existing extender unit Choose extender as template a template of an predefined extender type Choose extender type or no template None should be used 3 Press the button OK 4 Set all relevant parameters for the extender unit 5 Press the button Apply to save the new extender unit Created extender units are always set as fixed port extender These configurations are necessary if you want to switch e g USB 2 0 connections via the matrix Pos 52 806 IHSE Konfiguration CPU Einstellungen 480 xx 7 mod_1309938442055_6 doc 53216 4 5 7 CPU Settings New CPU devices are configured in this menu including their assignment to extenders The assignment helps to describe and switch more complex computer configurations e g Quad Head with USB 2 0 in the matrix You have the following possibilities to access the menu You can select between the following settings Field Selection Description ID Text ID of the CPU unit see Chapter 5 4 2 Page 61 Name Text Name of the CPU Device activated Create new CPU device as a virtual one Virtual Device deactivated Function not active Configuration 2011 10 11 81 OSD Select Configuration gt CPU Units in
69. extension distance is halved Pos 90 806 IHSE Technische Daten Verbindungskabel Verbindungskabel Cat X _Kabell nge 477 xx 5 mod_1278937761105_6 doc 43167 1 Maximum Acceptable Cable Length Cat X Installation Cable AWG24 140 m 400 ft Cat X Patch Cable AWG26 8 70 m 200 ft Pos 91 806 IHSE Technische Daten Verbindungskabel 480 xx Glasfaser 7 mod_1309942335305_6 doc 53729 4 Draco tera 116 2011 10 11 7 2 2 Fiber A point to point connection is necessary Operation with multiple patch panels is allowed Routing over active network components such as Ethernet Hubs Matrixes or Routers is not allowed Type of Interconnect Cable Cable notations according to VDE Type of cable Specifications Single mode 9 m Two fibers 9 m I V ZN H 2E9 in house patch cable I V ZN HH 2E9 in house breakout cable I AD ZN H 4E9 in house or outdoor breakout cable resistant A DQ ZN B2Y 4G9 outdoor cable with protection against rodents Multi mode 50 m Two fibers 50 m I V ZN H 2G50 in house patch cable I AD ZN H 4G50 in house or outdoor breakout cable resistant Multi mode 62 5 m Two fibers 62 5 m I V ZN HH 2G62 5 in house breakout cable A DQ ZN B2Y 4G62 5 outdoor cable with protection against rodents Only use Single mode connection cables for fiber connections that are based on 3G SFPs Maximum Acceptable Cable Length T
70. face Text folgt 5 11 2 Extender Update The firmware of the extenders connected to the matrix can be updated in this menu You have the following possibilities to access the menu 1 Select Administration gt Update EXT Firmware in the task area Draco tera 102 2011 10 11 Menu Administration gt Update EXT Firmware 2 Set the matrix into Service Mode upon request in the popup window or via Switch gt Activate Service Mode in the menu bar During activation all matrix functions are disabled An OSD picture indicates the activation of the Service Mode and is displayed on all monitors that are connected to the matrix via a CON device Additionally the Service Mode is indicated by a red tool icon in the lower part of the working area Configuration 2011 10 11 103 OSD View Service Mode 3 Select the directory in the lower part of the working area in which the update files can be found 4 Select those extender modules in the list that have to be updated and enable the respective checkbox in the column Update 5 Start the update by pressing the button Update in the lower part of the working area 6 Quit Service Mode after updating upon request in the popup window or via Switch gt Deactivate Service Mode in the task area Pos 66 806 IHSE Betrieb UEB_Betrieb 5 mod_1278577614980_6 doc 41970 1 1 Draco tera 104 2011 10 11 6 Operation Pos 67 806 IHSE Betrieb 480 xx 7 mod_1309
71. formation of the respective saved configuration are shown These storage locations can be overwritten The storage location that has to be overwritten by the current configuration must be selected explicitly Afterwards the current configuration will be saved to this storage location and will be immediately shown in the menu The previously saved configuration that has been saved to this storage location is deleted Draco tera 92 2011 10 11 OSD You have the possibility to save the created configuration within eight storage locations in the matrix File 1 File 8 Additionally a configuration can also be saved as default configuration 1 Select Configuration gt Save As in the main menu 2 Select the required storage location File 1 File 8 or Default Menu Configuration Save as Java Tool To save the configuration into the internal matrix memory proceed as follows 1 Select File gt Upload to in the menu bar 2 Enter the IP address of the matrix your user name and your password and select the storage location in that the configuration has to be saved default or config01 config08 3 Confirm with the button OK Configuration 2011 10 11 93 Menu File Upload to Pos 59 806 IHSE Konfiguration Speichern und Laden von Konfigurationen 480 xx Laden von Konfigurationen intern 7 mod_1309938889118_6 doc 53346 4 5 9 3 Loading of Configurations internal P
72. he new CPU with complete control Best results regarding switching time can be achieved by using identical mice keyboards and monitors This contributes to a smooth and delayless direct switching of the matrix Direct Switching of Video 1 Start Command Mode with the Hot Key For control the LEDs Shift and Scroll flashes at the keyboard if command mode is activated 2 Enter the index number of the new CPU from the list of favorites and confirm with lt Space gt At the same time the Command Mode is closed and the console is connected to the new CPU with video only You can only switch to not used and allowed CPUs with the Hot Keys The options Force Connect and Force Disconnect as well as the restrictions of the User ACL and CON ACL are taken into account Hot Keys are only supported if neither Enable User Login nor the Enable User ACL is selected and the user is logged in the OSD Pos 70 806 IHSE Betrieb Bedienung ber HotKeys 480 xx Scan Modus 7 mod_1309940746290_6 doc 53508 4 Draco tera 106 2011 10 11 6 1 2 Scan Mode The Scan Mode offers the possibility to show video signals of the different CPUs fast and without delay and offers switching in between without continuously using the Hot Key The switching between two video signals can even take place within one frame 1 Start command mode with the Hot Key For control the LEDs Shift and Scroll flashes at the keyboard if command mode is a
73. i mode 62 5 multi mode fiber cable or 50 multi mode fiber cable OSD The On Screen Display is used to display information or to operate a device Quad Head A system with four video connections RCA Cinch A not standardized plug connection for transmission of electrical audio and video signals especially with coaxial cables SFP SFPs Small Form Factor Pluggable are pluggable interface modules for Gigabit connections SFP modules are available for Cat X and fiber interconnect cables S PDIF A digital audio interconnect that is used in consumer audio equipment over relatively short distances Single Head A system with one video connection Single Link A DVI D interface for resolutions up to 1920x1200 by signal transmission of up to 165 MPixel s 24 bit Alternative frequencies are Full HD 1080p 2K HD 2048x1080 and 2048x1152 Single mode 9 single mode fiber cable S Video Y C The S Video Y C is a video format transmitting luminance and chrominance signals separately Thereby it has a higher quality standard than CVBS Draco tera 146 2011 10 11 Term Explanation TOSLINK Standardized fiber connection system for digital transmission of audio signals F05 plug connection Triple Head A system with three video connections USB HID USB HID devices Human Interface Device allow for data input There is no need for a special driver during installation New USB HID device found is reported Typi
74. ign real consoles to virtual consoles in this menu With this function the effort to set and change access permissions can be reduced by changing the permissions of the virtual console and so applying them to all assigned real consoles too You have the following possibilities to access the menu OSD Under development Configuration 2011 10 11 57 Java Tool Select Assignment gt Real to Virtual Console in the task area Menu Assignment Real to Virtual Console To place an assignment proceed as follows 1 Select the required real console in the table Real Console 2 Double click in the column Virtual Console to get a list of all available virtual consoles 3 Select the required virtual console You can select between the following buttons Button Function Send Send assignments to the matrix Cancel Reject changes By activating the function Auto Send in the left lower corner of the working area switching operations will be done immediately without confirmation by pressing the button Send The selection boxes in the column Virtual Console contain a filter function for an easy selection of single CPU from a larger pool of CPUs see Chapter 5 2 2 Page 47 Draco tera 58 2011 10 11 Pos 42 806 IHSE Konfiguration Systemeinstellung 480 xx Systemeinstellungen 7 mod_1309937961274_6 doc 53032 4 5 4 System Settings You have the possibility to configure the following system set
75. igured as sub matrix see Chapter 6 1 3 Page 106 1 2 3 3 4 6 3 7 5 Cascading Installation 2011 10 11 39 1 Source computer CPU 2 CPU unit 3 Interconnect cable 4 Draco tera sub matrix 5 Draco tera main matrix 6 CON unit 7 Console monitor keyboard mouse Pos 33 806 IHSE Konfiguration UEB_Konfiguration 5 mod_1278575517073_6 doc 41846 1 1 Draco tera 40 2011 10 11 5 Configuration Pos 34 806 IHSE Konfiguration Kommando Modus 480 xx 7 mod_1309936855602_6 doc 52882 4 5 1 Command Mode The Draco tera has a Command Mode that allows several functions via keyboard command during normal use To enter Command Mode use a Hot Key sequence and to exit Command Mode press lt Esc gt While in Command Mode the LEDs Shift and Scroll on the console keyboard will flash In Command Mode normal keyboard and mouse operation will cease Only selected keyboard commands are available The following table lists the keyboard commands to enter and to exit Command Mode and to change the Hot Key sequence Function Keyboard Command Enter Command Mode default 2x lt Right Shift gt or Hot Key Exit Command Mode lt Esc gt Change Hot Key sequence lt current Hot Key gt lt c gt lt new Hot Key code gt lt Enter gt Until 2011 30 09 lt Left Ctrl gt lt Left Shift gt lt c gt lt Hot Key Code gt lt Enter gt lt Key gt lt Key gt
76. ings Pos 78 806 IHSE Betrieb EIn und Ausschaltfunktionen 480 xx 480_Ausschalten 7 mod_1310646450471_6 doc 54300 4 6 4 3 Power Down Slide the on and off switch at the main sockets of the power supply units to start or switch off the matrix Pos 79 806 IHSE Technische Daten UEB_Technische Daten 5 mod_1278578165261_6 doc 42096 1 1 Draco tera 112 2011 10 11 7 Specifications Pos 80 806 IHSE Technische Daten Schnittstellen UEB_Schnittstellen 5 mod_1278578201870_6 doc 42114 2 1 7 1 Interfaces Pos 81 806 IHSE Technische Daten Schnittstellen DVI D Single Link 5 mod_1278578254058_6 doc 42132 3 1 7 1 1 DVI D Single Link The video interface supports the DVI D protocol All signals that comply to DVI D Single Link norm can be transmitted This includes e g monitor resolutions such as 1920x1200 60Hz Full HD 1080p or 2K HD up to 2048x1152 Data rate is limited to 165 MPixel s Pos 82 806 IHSE Technische Daten Schnittstellen USB HID 5 mod_1278578292214_6 doc 42150 3 1 7 1 2 USB HID Our devices with USB HID interface support a maximum of two devices with USB HID protocol Each USB HID port provides a maximum current of 100 mA Keyboard Compatible with most USB keyboards Certain keyboards with additional functions may require custom firmware to operate Keyboards with an integral USB Hub Mac keyboards e g are also supported Mouse Compatible with most 2 button 3
77. instellung 480 xx Switch 7 mod_1309938125852_6 doc 53104 4 Configuration 2011 10 11 67 5 4 4 Switch The configuration of the switching parameters is set in this menu You have the following possibilities to access the menu You can select between the following settings Field Selection Description activated The user can switch to any CPU as an observer even to such ones that are already assigned to another user observer without keyboard mouse access Note Switching with the key lt Space gt not lt Enter gt The operator will not be informed if further users connect as an observer to the CPU that is connected to his console Video Sharing deactivated Function not active default activated The user can connect to every single CPU as an operator even to such ones that are related to another user Note The previous user is set to video only status To share K M control Force Connect has to be activated Force Connect deactivated Function not active default activated Extension of Force Connect If the user connects to a CPU as an operator that is already related to another user the connection to the previous user will be completely disconnected Note To share K M control Force Disconnect has to be deactivated Force Disconnect deactivated Function not active default Draco tera 68 2011 10 11 Field Selection Description activated If a console
78. ix with 160 ports empty free configuration K480 080 Draco tera matrix with 80 ports empty free configuration K480 048 Draco tera matrix with 48 ports empty free configuration K480 008 Draco tera matrix with 8 ports empty free configuration Pos 9 806 IHSE Beschreibung Zubeh r 480 xx 7 mod_1309934367915_6 doc 52531 4 3 5 Accessories Part No Description 480 C8 Draco tera Cat X I O board 480 M8 Draco tera fiber I O board Multi mode 480 S8 Draco tera fiber I O board Single mode 480 SDI16 Draco tera I O board video 480 X8 Draco tera fiber I O board empty free configuration 480 CTRL Draco tera CPU board 459 1C Cat X GBIC for the use with Draco tera 459 1M Multi mode GBIC for the use with Draco minor major tera 459 1S Single mode GBIC for the use with Draco minor major tera 480 3M Multi mode GBIC for the use with Draco tera 3 125 Gbit s 480 3S Single mode GBIC for the use with Draco tera 3 125 Gbit s 480 TSHD Single mode GBIC transmitter dual unidirectional for the use with Draco tera HD SDI 480 TS3G Single mode GBIC transmitter dual unidirectional for the use with Draco tera 3G SDI 480 TBHD Koax GBIC transmitter dual unidirectional for the use with Draco tera HD SDI Draco tera 12 2011 10 11 Part No Description 480 TB3G Koax GBIC transmitter dual unidirectional for the use with Draco tera 3G SDI 480 RSHD Single mode
79. kabel 5 mod_1279191107845_6 doc 43870 2 1 7 2 Interconnect Cable Pos 89 806 IHSE Technische Daten Verbindungskabel Verbindungskabel Cat X 5 mod_1278578406026_6 doc 42205 3 1 7 2 1 Cat X A point to point connection is required Operation with several patch fields is possible Routing over an active network component such as an Ethernet Hub Router or Matrix is not allowed Avoid routing Cat X cables along power cables If the site has 3 phase AC power try to ensure that CPU Unit and CON Unit are on the same phase To maintain regulatory EMC compliance correctly installed shielded Cat X cable must be used throughout the interconnection link To maintain regulatory EMC compliance all Cat X cables need to carry ferrites on both cable ends close to the device Specifications 2011 10 11 115 Type of Interconnect Cable The Draco tera requires interconnect cabling specified for Gigabit Ethernet 1000BASE T The use of solid core AWG24 shielded Cat 5e or better is recommended Cat X Solid Core Cable AWG24 S UTP Cat 5e cable according to EIA TIA 568 B Four pairs of wires AWG24 Connection according to EIA TIA 568 B 1000BASE T Cat X Patch Cable AWG26 8 S UTP Cat 5e cable according to EIA TIA 568 B Four pairs of wires AWG26 8 Connection according to EIA TIA 568 B 1000BASE T The use of flexible cables patch cables type AWG26 8 is possible however the maximum possible
80. l interface Enable COM Echo deactivated Function not active default activated Send all performed switching commands in the matrix as an echo via LAN connection Note This function should be enabled when using a media control via LAN connection Enable LAN Echo deactivated Function not active default activated Synchronize the slave matrix according to the switch status of the master matrix Slave Matrix deactivated Function not active default Master IP Address Numerical value Set the network address of the master matrix default value 000 000 000 000 Draco tera 60 2011 10 11 OSD Select Configuration gt System in the main menu Menu Configuration System You can select between the following buttons Button Function Cancel Reject changes Save Save changes Configuration 2011 10 11 61 Java Tool Menu System System Data Pos 44 806 IHSE Konfiguration Systemeinstellung 480 xx Automatic ID 7 mod_1309938041118_6 doc 53068 4 5 4 2 Automatic ID The settings for the automatic creation of CPU and CON devices by connecting a new extender unit are made in this menu You have the following possibilities to access the menu You can select between the following settings Field Selection Description activated Automatic creation of a new CPU or CON device if new extender units are connected default Enable Auto Config deactivated Function not
81. l the CPU and I O boards 2 Connect keyboard mouse and monitor to the CPU board of the matrix 3 Connect the matrix to the power supply 4 Open OSD via Hot Key and login with administrator rights in the main menu under configuration see Chapter 5 2 1 Page 42 5 Configure initially as requested After the configuration of the system it is recommended to save the configuration by selecting Configuration gt Save and restart the matrix by selecting Restart Matrix 6 Optional Establish a network connection between the matrix and the Java tool in order to set an extended configuration see Chapter 5 2 2 Page 47 Draco tera 34 2011 10 11 Setup of Extender 1 Connect the CON units to the matrix by using the interconnect cables Cat X or fiber 2 Connect the CON units to the input devices that has to be used for example keyboard and mouse 3 Connect the 5VDC power supply units to the CON units 4 Check the basic function of the CON unit by opening the OSD via Hot Key 5 Connect the source computer CPU to the CPU unit of the extender by using the provided connection cables 6 Connect the CPU unit to the matrix by using the provided interconnect cables Cat X or fiber 7 If you have a video matrix connect the video source directly to the matrix by using the interconnect cables coax fiber 8 Connect the 5VDC power supply units to the CPU units 9 Start the system P
82. n between computer and matrix via switch or hub a parallel assembled network cable is required Connect the network cable to the RJ45 ports of computer and CPU board of the matrix Start of the Java Tool Open the Java Tool by a double click on the program icon or use the lt Enter gt key of the keyboard Draco tera 48 2011 10 11 Connection to the Matrix Administrator rights are required 1 Open the Java Tool 2 Select Switch gt Connect in the menu bar 3 Enter the IP address in the popup input field according to the network configuration of the Draco tera see Chapter 5 2 3 Page 54 4 Enter the user name and password for the Draco tera see Chapter 5 4 1 Page 58 5 Confirm your inputs with the button OK or reject with Cancel Menu Connect Up to eight connections between the matrix and the Java tool can be established at the same time due to a limitation of available sockets Configuration 2011 10 11 49 Menu structure Example View System Switch The menu structure of the Java Tools is subdivided into various sections Menu bar top line Toolbar second line Tab bar third line Task area left menu section Working area right menu section Status bar bottom line section Operating Instructions The operation of the Java Tool is intuitive and corresponds to the user interface of common operating systems The Java To
83. oard Execute Edit gt Reload in the menu bar Press the Button Reload in the tool bar Pos 19 806 IHSE Beschreibung Status Extender OSD 480 xx 7 mod_1317829749536_6 doc 54621 4 3 7 3 Extender OSD All extenders used with the Draco tera are standardly provided with their own OSD to display the connection status of the own console Example View Extender OSD Draco tera 26 2011 10 11 The following information is shown in the OSD menu Field Description CON Name of the own console CPU Name of the currently connected CPU Access Full Access The own console has a KVM connection to the displayed CPU Video Access The own console has a video only connection to the displayed CPU not connected The own console is not connected to a CPU If the options Mouse Connect or Keyboard Connect see Chapter 5 4 4 Page 67 are used the name of the console with keyboard mouse control will be displayed at those consoles that do not have K M control at the moment The console is displayed in yellow color under Access Pos 20 806 IHSE Beschreibung Status Netzwerk Status 480 xx 7 mod_1309935505711_6 doc 52680 4 3 7 4 Network Status The current network configuration is shown in this menu You have the following possibilities to access the menu The following information is shown in this menu Field Description DHCP Information if the network settings are applied dynamically
84. ol contains its own support function The manual of the Draco tera only describes how to find and open the appropriate menus in the Java Tool For further operation use the support function of the tool The integrated help texts in the working area of the Java Tool can be activated or deactivated by the checkbox in the upper right corner Draco tera 50 2011 10 11 Mouse Control You can select between the following mouse commands Function Mouse Command Menu selection marking Left mouse button Open function specific selection menus Double click left mouse button Open context specific selection menus Right mouse button Keyboard Control You can select between the following keyboard commands Function Keyboard Command Cursor to the left lt Cursor Left gt Cursor to the right lt Cursor Right gt Line up lt Cursor Up gt Line down lt Cursor Down gt Previous page in input or status menus with more than one page lt Page Up gt Next page in input or status menus with more than one page lt Page Down gt Next field in input menus lt Tab gt Previous field in input menus lt Left Shift gt lt Tab gt Switching in selection fields between two conditions checkmark or not Open already marked fields with editing or selecting possibility lt Space gt In menus Data saving Menu item selection lt Enter gt Leave tables Jump from tables into the nex
85. on stacking of several Draco tera devices One of the Draco tera matrices has to be defined as the master matrix all the others have to be configured as slave matrix and the IP address of the master matrix has to be entered in the field Master IP Address see Chapter 5 4 1 Page 58 They have to be connected to the master matrix via network connector RJ45 of the CPU board The option Enable LAN Echo has to be activated at the master matrix see Chapter 5 4 1 Page 58 If a switching command is done in the OSD the slave matrices will also switch automatically Switching of stacked devices might be delayed by several seconds 1 2 3 4 6 3 7 5 8 Parallel Operation Stacking Draco tera 38 2011 10 11 1 Dual Head source computer CPU 2 CPU unit 3 Interconnect cable 4 Draco tera matrix master matrix 5 Draco tera matrix slave matrix 6 Network connection master slave s 7 CON unit 8 Console 2x monitor keyboard mouse Pos 32 806 IHSE Installation Installationsbeispiele 480 xx Kaskadierung 7 mod_1309936471961_6 doc 52864 4 4 3 5 Cascading For applications exceeding the number of available ports the system can be extended by cascading In this case the Draco tera devices are connected by so called tie lines The tie lines are dynamically configured to support connections in both directions To access cascaded matrices from a console one of the matrices has to be conf
86. operations of the Draco tera matrix are logged and displayed in this menu This function is used for diagnostic purposes You have the possibility to request various trace views in the menu The following information is shown in this menu Field Description Time Timestamp Message Detailed description of the event Trace possibilities Select Status gt Trace IO Board in the main menu to check the events on your current I O boards Select Status gt Trace Matrix to check the matrix events Pos 23 806 IHSE Installation UEB_Installation 5 mod_1278574971589_6 doc 41768 1 1 Installation 2011 10 11 33 4 Installation Pos 24 806 IHSE Installation Lieferumfang pr fen 480 xx 7 mod_1309935842774_6 doc 52736 4 4 1 Package Contents Your package contains the following items Draco tera matrix 1x power cord per built in power supply unit 1x serial control cable Mounting accessories User Manual Java Tool 1x Cat X network cable cross wired If anything is missing contact your dealer Pos 25 806 IHSE Installation System anschlie en 480 xx 7 mod_1309935998118_6 doc 52754 4 4 2 System Setup First time users are recommended to setup the system in the same room as a test setup This will allow you to identify and solve any cabling problems and experiment with your system more conveniently Setup of the matrix 1 Instal
87. os 26 806 IHSE Installation Installationsbeispiele UEB_Installationsbeispiele_480 xx 7 mod_1311338893738_6 doc 54459 4 4 3 Example Applications The Draco tera supports a most flexible configuration of your system environment Pos 27 806 IHSE Installation Installationsbeispiele 480 xx Installationsbeispiele 7 mod_1309936170836_6 doc 52791 4 A part of the Draco tera can be configured as a Single Head work station a part as Dual Head as Quad Head or even as a video matrix for example In addition to that there are configurations with KVM and USB 2 0 available Among the access via OSD by the keyboard connected to the CPU board or an extender CON unit you have the following additional access options via Java Tool via serial interface A connection to common media controls is possible too The following part shows typical exemplary installations of the Draco tera Pos 28 806 IHSE Installation Installationsbeispiele 480 xx KVM Matrix 7 mod_1309936183571_6 doc 52810 4 Installation 2011 10 11 35 4 3 1 KVM Matrix In Single Head mode up to 288 ports can be used either as an input or as an output port depending on components and equipment At the same time there is a non blocking access for all users i e user access is not limited by the activities of another user 1 2 3 5 3 6 4 Single Head KVM Matrix 1 Source computer CPU 2 CPU unit 3 Interconnect cable 4 Dr
88. perating condition Off Operating condition 2 Status 2 blue On Error indication Off Hot Swap option deactivated 3 Hot Swap blue On Hot Swap option activated Draco tera 22 2011 10 11 Power Supply Unit Draco tera 288 160 1 2 3 Front View Status LEDs of the power supply units Pos LED Status Description 1 AC Input OK green On Operating condition 2 DC Output OK green On Operating condition Off Normal temperature 3 O T yellow On High temperature Power Supply Unit Draco tera 80 48 1 Front View Pos LED Status Description On Operating condition 1 DC Input OK green Off No power supply Pos 18 806 IHSE Beschreibung Status Port Status 480 xx 7 mod_1309935423961_6 doc 52661 4 Description 2011 10 11 23 3 7 2 Port Status The connections and the switching status between the various consoles and CPUs are shown in this menu You have the following possibilities to access the menu OSD Text kommt Java Tool The current port configuration of the Draco tera is illustrated in this menu Select Status gt Matrix View in the task area in online mode Menu Status Matrix View Draco tera 24 2011 10 11 The colors indicates the connection status Color Description Black Port not connected Yellow Video connection Green KVM connection The symbol indicates the extender that is recognized and defined at a certain
89. port Symbol Description Port connected to a CPU unit Port connected to a CON unit Port connected to an USB 2 0 CPU unit Port connected to an USB 2 0 CON unit Red framed ports are defined as fixed e g for USB 2 0 connections The port with a static blue frame is currently selected The ports with a flashing blue frame show the currently assigned connections To show the extender information of the currently selected port in the right part of the working area press the left mouse button The following information is available Field Description Extender Name Name of the selected extenders Extender Type Type of the selected extender Port ID Number of the selected port Device Name Name of the connected console or CPU Connections Listing of assigned connections to the marked port Full Access or Video Access Description 2011 10 11 25 To open the context menu for the currently selected port with further functions press the right mouse button The following context functions are available Function Description Open Extender The menu for definition of the currently selected extender is opened Open Device The menu for definition of the currently selected console or CPU is opened Switch The menu for execution of switching operations is opened To reload the Matrix View you have the following possibilities Press the key lt F5 gt of a connected keyb
90. raco tera USB 2 0 CON Unit 4x USB 2 0 Pos 96 806 IHSE Technische Daten Getestete Peripherie 480 xx Video Extender 7 mod_1311332121134_6 doc 54441 4 7 3 3 Video Extender Text kommt Pos 97 806 IHSE Technische Daten Serielle Ausstattung Serielle Ansteuerung 7 mod_1309942515852_6 doc 53784 4 Draco tera 120 2011 10 11 7 4 Serial Control To control the Draco tera via serial interface the following parameters certain parameters are used In order to communicate set the format for serial data transmission 115 2K 8 1 NO 115 2 KBAUD 8 data bits 1 stop bit no parity Command lt STX gt lt command byte CMD gt data bytes D0 DN lt ETX gt Optional elements Response lt ACK gt lt ECHO gt Optional elements lt ECHO gt reports the matrix sequences solicited by a command and thus the new switching status of the matrix The echo can be used to update user applications and to operate several matrices in parallel Parameter Description Command byte In the range 0x40 to 0x6F see list of allowed commands below Data bytes a Binary data In order to prevent that during the transmission of binary data control statements of control commands are transferred the data are divided into low nibble and high nibble The data are distributed to the low nibbles of two bytes and provided with an offset by 0x60 e g 0x1F gt 0x61 0x6F b 7bit data 0x0
91. reviously saved configurations are loaded in this menu You have the following possibilities to load configurations from files In Active the currently loaded configuration is displayed In addition to the default configuration up to eight further configurations can be loaded The selection of the configuration that has to be loaded can be made between eight personalizable configurations and the default settings The selected configuration is will be immediately loaded and displayed in the menu as Active The previously active configuration is deleted Draco tera 94 2011 10 11 OSD 1 Select Configuration gt Open in the main menu 2 Select the desired configuration 3 Load the configuration by pressing the key lt Enter gt Menu Configuration Open Java Tool 1 Select Administration gt Activate Configuration during online mode in the task area 2 Select the required configuration 3 Load the configuration by pressing the button Activate Configuration 2011 10 11 95 Menu Administration Activate Configuration on Switch Pos 60 806 IHSE Konfiguration Speichern und Laden von Konfigurationen 480 xx Speichern von Konfigurationen extern 7 mod_1309938846930_6 doc 53328 4 5 9 4 Saving of Configurations external Created configurations can be saved as a file and so become independent of the matrix and transportable You have the following possibility to access the menu
92. sconnect after a predefined period of time of inactivity from the respective CPU EXT Unit Part or extender board of a CON or CPU unit with a connection to the matrix A CON or CPU unit can consist of several EXT devices Force Connect Matrix function that allows to switch with the own console to a CPU that is already used and in doing so to take keyboard and mouse control The connected console so far loses K M control but keeps video Force Disconnect Matrix function that allows to switch with the own console to a CPU that is already used and in doing so to take KVM control The connected console so far loses complete KVM control Java Tool Java based control and configuration tool for the Draco tera matrix Draco tera 148 2011 10 11 Term Explanation Keyboard Connect Matrix function that allows taking over the keyboard control of an inactive console Macro Keys Programmable keys that can execute a stringing together of commands to the matrix Mouse Connect Matrix function that allows taking the mouse control of an inactive console Non Blocking Access Matrix configuration where no user can be disturbed by an activity of another user OSD Timeout Matrix function that closes the OSD automatically after a predefined period of time of inactivity Release Time Matrix function that allows a console that is connected with the same CPU to release the K M control after a predefined time Tie Line Communic
93. search field and the list of results Find lt F6 gt Draco tera 46 2011 10 11 Password request You have to login with administrator rights to be able to set configurations Menu Login Access to the configuration menu requires administrator rights User login is mandatory Field Input User admin Password admin For security reasons please change the administrator password as soon as possible see Chapter 5 4 1 Page 58 Pos 37 806 IHSE Konfiguration Ansteuerung 480 xx Ansteuerung via Java Tool 7 mod_1309937697743_6 doc 52938 4 Configuration 2011 10 11 47 5 2 2 Control via Java Tool Requirements If you want to use the Java Tool the following requirements have to be fulfilled Computer with an executable Java Tool and an installed Java Runtime Environment JRE version 1 6 or higher Java Tool software Available network connection between the Java Tool and the matrix Contact your system administrator concerning JRE and network connection Installation of the Java Tool The Java Tool is available as a single executable program file that does not require a separate installation Copy the tool after receiving the file to a directory on your computer If you do not have a Java Tool contact your dealer Computer Connection to the Matrix For a direct connection between computer and matrix a cross wired network cable is required For a connectio
94. t Status gt Matrix Firmware in the task area Menu Status Matrix Firmware 2 To read out the firmware status and store it locally file extension dtf select Switch gt Save Firmware Status to File 3 To read out the overall status of the matrix and store it locally file extension zip select Switch gt Save Status to File The various modules can expanded and retracted in the column Name by clicking with the left mouse button on the plus or minus symbols to get a better overview By clicking on the plus resp minus symbol in the upper right corner of the working area you can expand and retract all module information with one click at the left mouse button Description 2011 10 11 31 3 7 6 Firmware Status Extender The current firmware status of the connected extenders is shown in this menu You have the following possibility to access the menu The following information is shown in this menu Field Description Name Description of the firmware Type Description of the extender module Ports Number of ports Cur Version Description of the current firmware version Cur Date Date of the current firmware version Select Status gt EXT Firmware in the task area Menu Status EXT Firmware Pos 22 806 IHSE Beschreibung Funktion Trace 480 xx 7 mod_1309935652618_6 doc 52718 4 Draco tera 32 2011 10 11 3 8 Trace Function All events e g activities and switching
95. t field lt Ctrl gt lt Tab gt Leave tables Jump from tables into the previous field lt Ctrl gt lt Left Shift gt lt Tab gt Various functions within the menus in the menu bar can be executed with the provided keyboard commands e g press lt Ctrl gt lt S gt to execute Save that are listed to the right of the respective menu item Configuration 2011 10 11 51 Reload Options The information shown in the Java Tool can be reloaded in different ways Via lt F5 gt key on the used keyboard Via Edit gt Reload in the menu bar Via Reload Symbol in the symbol bar Context Function The Java Tool offers several context functions that support a user friendly and effective operation of the tool The context functions are described in the respective chapters To execute a context function use the right mouse button on the corresponding field and select the desired function Sorting Function Lists and tables in the Java Tool offer a sorting function for fast and smooth search 1 For ascending sort status use the left mouse button once to click into the header of the column to be sorted The sort status is indicated by an arrow that points upwards 2 For descending sort use the left mouse button twice to click on the header of the column that has to be sorted The sort is displayed by an arrow that points downwards 3 To cancel the sort use the left mouse
96. tings at the Draco tera The configuration of the system settings can only be set by users with administrator rights Pos 43 806 IHSE Konfiguration Systemeinstellung 480 xx System Data 7 mod_1309938005493_6 doc 53050 4 5 4 1 System Data The system configuration is set in this menu You have the following possibilities to access the menu You can select between the following settings Field Selection Description Device Text Enter the device name of the matrix default SWITCH_01 Name Text Enter the name of the configuration that is used to save the current settings default Standard Info Text Additional text field to describe the configuration default Factory settings activated If the matrix is defined as a sub matrix in the OSD the user will loose control automatically Control can be recovered by using the keyboard command lt Shift gt lt Shift gt lt s gt lt o gt The OSD now will be opened again in the matrix that has been defined as sub matrix Sub Matrix deactivated Function not active default activated Save the current configuration of the matrix in the flash memory periodically Auto Save deactivated Function not active default Configuration 2011 10 11 59 Field Selection Description activated Send all performed switching commands in the matrix as an echo via serial interface Note This function should be enabled when using a media control via seria
97. ver identification 0X5D 1 Command 0x42 2 Total length of telegram 9 bytes binary 0x09 0x00 2 Requested output port binary 1 max ports 0x01 0x00 for port 1 to 0x120 0x00 for port 288 2 Assigned input port binary 1 max ports 0x01 0x00 for port 1 to 0x120 0x00 for port 288 Example Return of input port 17 for output port 160 0x1B 0x5D 0x42 0x09 0x00 0xA0 0x00 0x11 0x00 Specifications 2011 10 11 123 Connection of Input Port with Output Port Bytes Description Coding 1 Control character 0x1B 1 Server identification 0X5B 1 Command 0x43 2 Total length of telegram 9 bytes binary 0x09 0x00 2 Requested output port binary 1 max ports 0x01 0x00 for port 1 to 0x120 0x00 for port 288 2 Assigned input port binary 1 max ports 0x01 0x00 for port 1 to 0x120 0x00 for port 288 Example Connection of input port 17 with output port 160 0x1B 0x5B 0x43 0x09 0x00 0xA0 0x00 0x11 0x00 Request of Input Port for Output Port with a fixed total Port Number Bytes Description Coding 1 Control character 0x1B 1 Server identification 0X5B 1 Command 0x44 2 Total length of telegram 9 bytes binary 0x09 0x00 2 Number of output ports binary 1 max 287 ports 0x01 0x00 for 1 port to 0x11F 0x00 for 287 ports 2 Requested output port binary 1 max ports 0x01 0x00 for port 1 to 0x120 0x00 for port 288 Example R
98. waste electrical and electronic equipment WEEE The device labels carry a respective marking Pos 128 806 IHSE Zertifikate ATB_RoHS 5 mod_1278579714214_6 doc 42722 2 1 10 4 RoHS This device complies with the EC Directive 2002 95 EG on the Restriction of the use of certain Hazardous Substances in electrical and electronic equipment RoHS The device labels carry a respective marking Pos 129 806 IHSE Glossar ATB_Glossar 5 mod_1278576825433_6 doc 41890 1 1 Draco tera 144 2011 10 11 11 Glossary The following terms are commonly used in this guide or in video and KVM technology Term Explanation AES EBU Digital audio standard that is officially known as AES3 and that is used for carrying digital audio signals between devices Cat X Any Cat 5e Cat 6 Cat 7 cable CGA The Color Graphics Adapter CGA is an old analog graphic standard with up to 16 displayable colors and a maximum resolution of 640x400 pixels Component Video The Component Video YPbPr is a high quality video standard that consists of three independently and separately transmittable video signals the luminance signal and two color difference signals Composite Video The Composite Video is also called CVBS and it is part of the PAL TV standard CON Unit Component of a Draco tera or Media Extender to connect to the console monitor s keyboard and mouse optionally also with USB 2 0 devices CPU Unit Component of a
99. wn without wrap around lt Cursor Down gt Previous page in menus with more than one page lt Page Up gt Next page in menus with more than one page lt Page Down gt Next input field lt Tab gt Previous input field lt Left Shift gt lt Tab gt Next option in selection fields lt gt Previous option in selection fields lt gt Switching in selection fields between two conditions e g between ON OFF or Y Yes N No lt Space gt In menus with input fields Save data In menus Select menu item lt Enter gt In menus with input fields Cancel data input without saving In menus with selection fields Go back to the superior menu lt Esc gt Configuration 2011 10 11 45 Sorting Function Lists and tables in the Java Tool offer a sorting function for fast and smooth search You have the possibility to use the following sorting functions Function Keyboard Command Sort ID numbers in a descending order or in an ascending order by pressing the keyboard command twice ID lt F1 gt Sort ID names in a descending order or in an ascending order by pressing the keyboard command twice Name lt F2 gt Go to the next result in the list of results of the search field Next lt F3 gt Go to the previous result in the list of results of the search field Previous lt F4 gt Refresh the currently shown list Refresh lt F5 gt Jump between the
100. x 7 mod_1309943583946_6 doc 53948 4 7 6 Power Supply Voltage 100 240V 50 60Hz Strombedarf Draco tera 288 max 202 W without I O boards Draco tera 160 max 188 W without I O boards Draco tera 80 max 99 W without I O boards Draco tera 48 max 94 W without I O boards Draco tera 8 max 15 W without I O boards I O Board max 13 W Pos 112 806 IHSE Technische Daten Einsatzbedingungen ATB_Einsatzbedingungen 5 mod_1278578980026_6 doc 42480 2 1 7 7 Environmental Conditions Operating Temperature 41 to 113 F 5 to 45 C Storage Temperature 13 to 140 F 25 to 60 C Relative Humidity Max 80 non condensing Pos 113 806 IHSE Technische Daten Abmessungen 480 xx 7 mod_1309943734415_6 doc 53966 4 Draco tera 136 2011 10 11 7 8 Size Draco tera 288 Matrix 483 x 578 x 330 mm 19 0 x 22 8 x 12 0 Shipping Box 650 x 680 x 760 mm 25 6 x 26 8 x 29 9 Draco tera 160 Matrix 483 x 400 x 330 mm 19 0 x 15 8 x 12 0 Shipping Box 650 x 680 x 540 mm 25 6 x 26 8 x 21 3 Draco tera 80 Matrix 483 x 178 x 230 mm 19 0 x 7 0 x 9 1 Shipping Box 640 x 570 x 360 mm 25 2 x 22 4 x 14 2 Draco tera 48 Matrix 483 x 133 x 230 mm 19 0 x 5 3 x 9 1 Shipping Box 640 x 570 x 316 mm 25 2 x 22 4 x 12 4 Draco tera 8 Matrix Shipping Box Pos 114 806 IHSE Technische Daten Transportgewicht 480 xx 7 mod_1309943775602_6 doc 53984
101. x USB HID L477 1S4CA Draco tera KVM CPU Unit Single Head Analog Audio 4x USB HID R477 1S4CA Draco tera KVM CON Unit Single Head Analog Audio 4x USB HID Draco tera 118 2011 10 11 Type Description L477 1S4CD Draco tera KVM CPU Unit Single Head Digital Audio 4x USB HID R477 1S4CD Draco tera KVM CON Unit Single Head Digital Audio 4x USB HID L477 1STC Draco tera KVM CPU Unit Single Head 2x USB HID 4x USB 2 0 R477 1STC Draco tera KVM CON Unit Single Head 2x USB HID 4x USB 2 0 L477 2S4C Draco tera KVM CPU Unit Dual Head 4x USB HID R477 2S4C Draco tera KVM CON Unit Dual Head 4x USB HID L477 SHCV Draco tera KVM CPU Unit Single Head DVI I input VGA 2x USB HID R477 SHCV Draco tera KVM CON Unit Single Head DVI I Input VGA 2x USB HID KVM Extender with Cat X Connection K474 Series Type Description L474 BSHC Draco tera KVM CPU Unit Single Head 2x USB HID R474 BSHC Draco tera KVM CON Unit Single Head 2x USB HID L474 BSHCV Draco tera KVM CPU Unit Single Head DVI I input VGA 2x USB HID R474 BSHCV Draco tera KVM CON Unit Single Head IR receiver 2x USB HID KVM Extender with Fiber Connection Single Mode K477 Series Type Description L477 1SHS Draco tera KVM CPU Unit Single Head 2x USB HID R477 1SHS Draco tera KVM CON Unit Single Head 2x USB HID L477 1S4SA Draco tera KVM CPU Unit Single Head Analog Audio 4x USB HID R477 1S4SA Draco tera
102. y Confirm a created CON device Cancel Reject changes gt Assign selected extender units gt gt Assign all available extender units lt Remove the selected extender units lt lt Remove all extender units You can select between the following keyboard commands Function Keyboard Command Decrease assignment number of the extender unit lt gt Increase assignment number of the extender unit lt gt Configuration 2011 10 11 87 To create a new console proceed as follows 1 Press the button New 2 Select if a real console Create a real Console or a virtual console Create a virtual Console should be created or a template of an existing console should be used Choose template A template can only be used if there is at least on existing CON device 3 Press the button OK 4 Determine all parameters that are relevant for the console 5 To confirm a created console press the button Apply To run a created CPU via matrix it requires an assignment of one or more CON units extender To place an assignment please proceed as follows 1 Select the console in the list CON Devices that has to be assigned to an extender 2 Select the extender in the list Extender available that should be assigned to the CON 3 Perform the assignment by pressing the button gt To assign all available extenders to the console press the button gt gt The assignments are displayed in the
103. y of the list to import 4 Confirm the import with the button Finish Menu File Import Pos 65 806 IHSE Konfiguration Firmware Aktualisierung 480 xx Firmware Aktualisierung 7 mod_1313482000731_6 doc 54542 233 4 Draco tera 100 2011 10 11 5 11 Firmware Update 5 11 1 Matrix Update The firmware of the matrix can be updated in this menu You have the following possibility to access the menu Java Tool Only use computers to update the matrix that are self sustaining and not integrated in the KVM extender matrix setup 1 Select Administration gt Update Matrix Firmware in the task area Menu Administration Update Matrix Firmware 2 Select the directory in the lower part of the working area in which the update files can be found Open the file defaults cfg and insert in the parameter upd dir the directory from which the update files should be standardly sourced Configuration 2011 10 11 101 3 Select those modules in the list that have to be updated and enable the respective checkbox in the column Update 4 Start the update by pressing the button Update in the appearing pop up window 5 If the expected period of time for one update will exceed 20 minutes cancel the update Open the file defaults cfg and set the parameter safemode to true 6 Restart the Matrix after the update by pressing the button Restart matrix in the lower part of the working area Serial Inter
104. ype of cable Maximum Acceptable Cable Length Single mode 9 m 10 000 m 32 800 ft Multi mode 50 m OM3 1 000 m 3 280 ft Multi mode 50 m 400 m 1 300 ft Multi mode 62 5 m 200 m 650 ft If you use single mode SFPs with multi mode fibers you normally can double the maximum acceptable cable length Specifications 2011 10 11 117 Type of Connector Connector LC Connector Pos 92 806 IHSE Technische Daten Verbindungskabel Koaxial 7 mod_1309942381352_6 doc 53747 4 7 2 3 Coaxial A point to point connection is necessary Type of Interconnect Cable Cable Type Specifications Mini coaxial cable AWG 18 RG 6 impedance 75 Maximum Acceptable Cable Length Band Width Maximum Acceptable Cable Length 0 270 Gbit s 400 m 1 312 ft 1 485 Gbit s 140 m 459 ft 2 970 Gbit s 120 m 394 ft Type of Connector Connector Mini BNC connector Pos 93 806 IHSE Technische Daten Getestete Peripherie UEB_Getestete Peripherie 5 mod_1278578478761_6 doc 42242 2 1 7 3 Supported Peripherals Pos 94 806 IHSE Technische Daten Getestete Peripherie 480 xx KVM Extender 7 mod_1311332022151_6 doc 54403 4 7 3 1 KVM Extenders The following KVM extenders are released for the use with the Draco tera KVM Extender with Cat X Connection K477 Series Type Description L477 1SHC Draco tera KVM CPU Unit Single Head 2x USB HID R477 1SHC Draco tera KVM CON Unit Single Head 2
Download Pdf Manuals
Related Search
Related Contents
Troubleshooting Guide.pub HCV Real TM Genotype ENG 040113 Sem título-1 - Kalunga.com Run Manager Module for CORAL Laboratory Copyright © All rights reserved.