Home
EMDE13011452 EMAUX激流喷嘴EM0055 英文说明书 20130510
Contents
1. XTPENLLIL2L3 L1L2L3 2 2 113 5 K2 i K2 i KMT HH 97 95 96 F2 F2 HY 95 214 6 98 o6 T1IT2T3 A2 KM i E TBM 8 d transformer X1 1 2 3PEPE T ilh LED I ar d M S 3 zd p X pneumatic switch 380V 50Hz counter current jet circuit diagram 18 1 safety precautions 1 Important note the basic requirements of installation usage and maintenance process of users are included in the safety operating instructions 2 Please follow safety instructions carefully Failure to adhere to safety instructions could lead to personal injury Please pay special attention to wiring of 3 phase motors to ensure shaft rotation is in the direction of arrow 3 Installation must be carried out by qualified persons Electrical work must be carried out by a qualified electrician 4 Emaux Water Technology is not liable for any damages personal or property if equipmentis installed by unauthorized persons or not in line with installation and safety instructions provided 5 Please read instructions and operating instructions thoroughly 6 Please ensure pool water is balanced at all times Operating equipment above the maximum water temperature will lead to damages The safety instructions for repair and maintenance inspection and the operation engineering must ensure th
2. EMAUX UT A S Water Technology Product Name COUNTER CURRENT JET Product Model No EM0055 Please read this manual carefully before using the product please keep this manual for future reference EMDE13011452 O oc A OO N INDEX z oafety precau tlolis x side aN x exe A E AN adea s 9pecificatiOns eee ava aie LEHRER YET AX YA addas Product structure and name of components suus Installation instructions sss s Operating instr ctlOris i iiic en eh ces uv Vas Maintenance and warrenty cicer dis sate mir tei sh Control box instructions sissa scs sn 4 6 744 15 15 16 19 PART LIST Item No Part No Product Description QTY 1 04014099 thermal overload relay 1 2 04014100 AC contactor 1 3 04014101 breaker 2 4 04014103 pneumatic switch 2 5 04014102 earth terminal 1 6 04014019 track 1 7 04014104 terminal fixing parts 2 8 04014107 clapboard 3 9 04014108 wiring terminal 2 10 04014105 head board 2 11 04014109 transformer 1 12 04014110 control box 1 13 04014013 cable gland 1 14 04014085 cable gland 2 DROO Soe amp 660602606 Q TA water light cable input power 380V 380V control box wiring diagram
3. Screw M4x30 SUS304 4 11 Light Spring Washer d12 SUS304 1 36 Wave Spring Washer D40 65Mn 1 12 Flat Key 4x12 SUS304 1 37 Back Motor Cover ADC12 1 13 O Ring d252x24 NBR 1 38 Hexagon Screw M5x190 SUS304 4 14 Impeller PA66 GF 1 39 Fan PP 1 15 Mechanical Seal SB 20 Carbon Ceramic NBR 1 40 Shaft spring pad d14 1 16 Screw M8x35 SUS304 4 41 Fan Cover ABS PC 1 17 Pad PA6 4 42 Belt pad screws SUS304 4 18 O Ring d6x2 NBR 4 43 Rubber Strap NBR 1 19 Pump Cover PP GF 1 44 Hexagon Screw M8x16 SUS304 2 20 Shaft Washer d20 NBR 1 45 Pad 08 SUS304 2 21 Nut M10 SUS304 6 46 Bracket PP GF 1 Pump parts for SR SES iV j D KAJ R le a Y e P Y A Key No Part No Product Description Qty 1 89280306 2 0 Union 2 2 89023601 Connecting 1 3 89021308 SR Pump body 1 4 89021309 Screw for impeller with O ring 1 5 02011108 O Ring for diffuser 1 6 01111015 Diffuser 1 7 01311006 Impeller SR300 220V 50HZ 1 8 04015001 3 4 Mechanical seal 1 9 02011093 O Ring for flange 1 10 01021013 SR Pump Flange 1 11 03011080 M6x15 Hexagonal screw 16 12 02011101 Motor Slinger for 1 13 89021304 Motor SR300 220V 50HZ 1 14 89021310 M8x20 Screw for motor with washer 4 15 01111031 Base with nut amp washer for 1 16 01021021 Opening key 1 5 Operating Instructions 1 the water in the swimming pool is sucked from the side of the no
4. BEFORE SERVICE AND MAINTAINANCE INSTALLATION EXPLAIN 1 The control box must be installed in a dry place 2 After the control box is fixed According to the wiring diagram the pump and the water light power cord access control box 3 Connect the two transparent air pipes to the corresponding pneumatic switches SPECIFICATIONS Input voltage 220V 380V Water light output voltage AC 12V Pump output voltage 220V 380V Water light power 1W Pump power 4KW 2 AFS40 55 parts list NO Component Specification Material QTY NO Component Specification Material QTY 1 Tie in Nut G2 ABS 2 22 Front cover ADC12 1 1a Tie in Nut 3 ABS 2 23 Bearing 6205 1 2 Tie in 0603963 PVC 2 24 Rotor 1 2a Tie in 075 290 PVC 2 25 Bearing 6203 1 3 O Ring d62x45 NBR 2 26 Stator 1 3a O Ring d936x5 7 NBR 2 27 Motor House ADC12 1 4 Drainage Plug PA66 GF 2 28 Terminal Box Pad NBR 1 5 O Ring d112x24 NBR 2 29 Connection Pole Melamine Plating Zinc 1 6 Screw M10x130 SUS304 6 30 Screw M4x12 Plating Zinc 1 7 Pad O10 SUS304 6 31 Spring washer 5 SUS304 2 8 Pump Casing G2 PP GF 1 32 Pad 5 SUS304 2 8a Pump Casing 4VFBT PP GF 1 33 Screw M4x12 SUS304 2 9 O Ring d208x6 NBR 1 34 Terminal Box Flame Besistant ABS 1 10 Impeller Nut PA6 GF 1 35
5. Union Ball Valve PVC PIPE 2 5 105mm 2 5 PIPE ELBOW 45 2 5 PIPE ELBOW 45 PVC PIPE 2 5 120mm 9 2 5 PIPEELBOW 45 10 PVC PIPE 2 5 105mm 11 2 5 Union Ball Valve 12 PVC PIPE 2 5 105mm 13 2 5 PIPE ELBOW 90 14 PVC PIPE 2 5 175mm remarks Please take reference Fig ure14 from the above piping sequence only for AFS40 50 water pump 13 Figure 11 Figure 12 12 air switch 3 to install a counter current jet shell onto a vinyl pool a for vinyl pool according to the 16 holes on the counter current jet shell first drill holes on the structural wall accordingly Figure 5 b install the plastic ring and the outer shell with 2 M6 20 screws hole 3 of Figure 5 and then install the plastic ring and ring for installing on the fiber pool using 10 M6 45 screws Figure 6 250 310 o09E 06 7 Figure 5 nozzle shell outer pool wall inner pool wall O ring compressedring screw Figure 6 9 4 The structure of cement bag from inside of the pool and the outercasing installation methods of counter current jet a Embedded the counter current jet outer casing inside the cement wall and the surface of the outer case should be completed with the cement surface figure 8 b Opened the corresponding holes from inside of the cement bag and the holes should be completed with the
6. repair in the freezing winter it is necessary to lower the water level which is lower than that of the nozzle shell flow out all of the water in both the inlet and outlet water pipes 5 when the control box is out of order it must be maintained by qualified electricians or qualified maintainance staff for details please refer to the control box user manual No Specification 4 Installation instructions a peepee MM 7 the counter current jet can be used in Concrete composite 2 2 PIPE ELBOW 45 fiberglass and vinyl pools The installation is as follow 3 PVC PIPE 2 70mm LY 1 Concrete pool installation 4 2 Union Ball Valve a Use 4 screws M6 20 to fix the counter current jet plate to the 5 PVCPIPE2 100mm pool wall hole Figure 1 6 REDUCING PIPE 2 5 2 b Fit counter current jet body into in to concrete wall Figure 2 7 PVC PIPE 2 5 105mm 8 2 5 PIPE ELBOW 45 9 REDUCING PIPE 2 5 2 10 PVC PIPE 2 170mm 11 2 Union Ball Valve 12 PVC PIPE 2 220mm 13 2 PIPE ELBOW 90 2 5 I 14 PVC PIPE 2 170mm Figure15 q remarks Please take reference from the above only for SR30 water pump 7
7. at the performance of repair and maintenance checking and installation are approved by qualified technician to work Staff responsible for the work need read the manual thoroughly The industrial accident prevention rules must be obeyed All the work relating to pump only can be done when itis stopped The procedures mentioned in the operating instructions of the pump must be obeyed The products harmful to health carried by the pump or counter current jet must be purified If the box has been opened please check all components are supplied 9 counter current jet is a countercurrent facility using in any swimming pools N Co x 2 Specifications CONTROL BOX WIRING DIAGRAM amp CIRCUIT DIAGRAM 1 Pump model parameters Hmax V Hz AFS40 7 1300 1 Lae so s OOOO 3 AFS55 1500 SR30 20 SR30 e0 20 soso SR30X2 1200 3 Product description and parts breakdown 1 counter current jet parts list ooo Key No Part No Product Description Qty 1 89090104 Air switch for water pump 1 aa 2 89090105 Air ajusting 1 salarighi cable input pow
8. er 220V 7 7 pump cable 3 89090106 Air switch for water light 1 4 89090107 Threaded plug for lid 1 220V control box wiring diagram 5 03011345 M5 20mm screws 4 6 89090108 Lid 1 xi 88041939 LED P10 light Auto change colour 1 Pg N L T 88041940 LED P10 light White colour 1 17 5 8 89090110 Support frame 1 N IL 2 2 Kn K2 9 89090111 Water jet 1 KM e 9795 F2 96 10 01093016 D12mmXd8mmX40mm air ajusting hose 2 F20 T 95 9896 11 01093015 D5mmXd3mmxX3M transparent hose 2 Ku 12 03011320 M6X20mm srews 4 i z 1 E P 13 89090112 Water jet fixed pipe 1 T1 Beg transformer XI TTZ3PdE 14 89090113 Vinyl pool fittings 1 15 89090114 Counter Current Jet body 1 7 E 7 7 16 89090115 Conduit for light cable and air hose 1 3 H LED 17 89090116 Cable grand 1 M NL m 17 li 19 27 18 01151380 Exhaust hose 1 NG C pneumatic switch 19 89090117 Venting plu 1 T SEN 220V 50Hz counter current jet circuit diagram 4 17 COUNTER CURRENT JET CONTROL BOX Model SWJ CB 220V 380V Code 08080020 08080021 APPLICABLE FOR BETWEEN EMAUX COUNTER CURRENT JET AND PUMP CONTROL Warning This electrical control box must be installed by a licensed or certified electrician or a qualified serviceman in accordance to the requirements of your government standard or local authorities Improper installation will create electric hazards which could result in serious injury death as well as damage to the property CUT THE POWER
9. fiber pool figure 3 c Used 10 screws of M6X30 and fixed the rubber ring into the mounting ring figure 8 cement bag concrete structure Figure 7 concrete pool wall cement bag nozzle shell O ring compressed ring Figure 8 10 Il to install counter current jet outer shell 1 first use 5 transparent air tube and LED light cable respectively to pass through the connecting tube then connect the two air pipes to the pump switch and pool light air switch respectively Figure 9 2 pass through the two pipes respectively from the hole of the support frame and then use 4 M6 screws to fix the support frame onto the shell Figure 10 3 connect the pipes of the shell to the side of the mask of the air button Connect the gas nozzle of the support frame to the middle of the gas nozzle Figure 11 Note must not be reversed 4 install the outer shell onto the support frame fixed with 4 M5 screws and then cork the screw hole using plastic cork Figure 12 water lamp air on off Figure 10 11
10. piping sequence No Specification 1 2 5 PIPE TEE 2 PVC PIPE 2 5 105mm 3 PVC PIPE 2 5 105mm 4 2 5 PIPE ELBOW 90 5 2 5 PIPE ELBOW 90 6 PVC PIPE 2 5 105mm 7 PVC PIPE 2 5 105mm 8 REDUCING PIPE 2 5 2 9 REDUCING PIPE 2 5 2 10 PVC PIPE 2 95mm 11 PVC PIPE 2 95mm 12 2 PIPE ELBOW 90 13 2 PIPE ELBOW 90 14 PVC PIPE 2 125mm 15 PVC PIPE 2 125mm eT 16 2 Union Ball Valve 4E 4 ds 17 2 Union Ball Valve 4 4R cement structural layer 18 PVC PIPE 2 70mm a lt p 19 PVC PIPE 2 70mm T V wall 20 2 5 PIPE TEE poole 21 PVC PIPE 2 5 105mm ae Lt J ftm 22 PVC PIPE 2 5 105mm 23 2 5 PIPE ELBOW 90 24 2 5 PIPE ELBOW 90 es PVC PIPE 2 5 105mm PVC PIPE 2 5 105mm 27 REDUCING PIPE 2 5 2 Ll 28 REDUCING PIPE 2 5 2 29 PVC PIPE 2 95mm 30 PVC PIPE 2 95mm 31 2 Union Ball Valve Ns 32 2 Union Ball Valve 33 PVC PIPE 2 70mm ous OLR 34 PVC PIPE 2 70mm M p a N x 2 PIPE ELBOW 90 Figure16 ye Wd nozzle shell 2 PIPE ELBOW 90 a tu NT B BUG PIPED SE only for 2XSR30 water pump S S 38 PVC PIPE 2 150mm remarks Please take reference Figure 2 from the above piping sequence 7 2 Composite Fibreglass pool installation a Using the template drill 14 holes into the fibgrelass pool shell Figure 3 b Install the outer shell plastic ring in the correct order on the pool shell wall Figure 4 c Mount the counter current jetfaceplate onto the fiber pool
11. using 10 piece of M6 screws Hole 1 in Figure 3 250 310 2067 o09E Figure 3 nozzle shell vinyl pool wall O ring compressed ring screw Figure 4 8 Ill Installation of counter current jet 1 please refer to figure 13 for the whole installation 2 for each model of pump pipe please refer to figure 14 15 16 3 pumps and contror box must be installed in dry areas It is absolutely necessary to expel water at the bottom part 4 in order to ensure normal operation of air switch the distance between the swimming pool and the controller box must not be more than 3 meters 5 the air pipe must be installed in the protective pipe It can be replaced if necessary 6 the installation of electric connections must be performed by a qualified electrician air valve ER 380V power supply input wire Pi ai tas A BL 25cm J gii water lamp power Source wire swimming pool Il D water pump power source wire water pump 380V 220V Figure13 z o lN on A IN gt Specification PVC PIPE 2 5 175mm 2 5 PIPE ELBOW 45 PVC PIPE 2 5 105mm 2 5
12. zzle mask to the water pump and then expelled through the nozzle 2 the on off switch of the water pump and the water lamp are installed on the cover of the nozzle It can be operated only by hand press 3 the direction of the water output can be adjusted by moving the nozzle up and down left and right while rotating the nozzle can adjust the amount of the water output 4 if air is needed to be injected into the water the adjustable valve on the mask surface can be regulated Note keeping rotating counter clockwise can twist off the valve 5 since during testing three phase alternating current is used the correct rotating direction of the arrow shown on the fan cover of the engine must be found to indicate the correct rotating direction of the motor of the water pump maintenance and warrenty 1 clean the nozzle the pump and the surface of the control box regularly check the water pump and the area where plastic nozzle ring is sealed regularly Change if needed 2 keep the motor clean to ensure ventilation position fan cover does not have any obstacles 3 when uninstalling the pump the pump switch must be closed and all power must be disconnected The replacement must be performed by a professional officer Please refer to the user manual for the Isolation of screw nuts of the inlet and outlet pipe connected to the pump replacement of mechanical seals and the order of assembly installation 4 when maintenance
Download Pdf Manuals