Contents

1. ID Access Name Value 1 Get Vendor ID 90 2 Get Device Type 100 3 Get Product Code 85 4 Get Revision 1 5 Get Status 1 6 Get Serial Number fe T Get Product Name Netbiter Services The following services are implemented Code Instance Service Name 0x01 Get Attribute_All Ox0E Get_Attribute_ Single TCP IP Interface Object 0xF5 Class Attributes The following class attributes are implemented UD Access Name Instances Instance 1 is implemented with the following attributes ID Access Name 1 Get Status 2 Get Configuration Capability 3 Get Configuration Control 4 Get Physical Link Object 5 Get Interface Configuration 6 Get Hostname 13 Get Set Encapsulation Inactivity Timeout Services The following services are implemented Code Class Instance Service Name Ox0E No Yes Get Attribute Single 0x10 No Yes Set Attribute Single Netbiter EasyConnect Gateway User Manual Doc ID HMSI 168 92 Version 4 00 EtherNet IP Implementation 50 60 11 2 3 Ethernet Link Object 0xF6 Class Attributes No attributes are implemented Rev 1 Instances Instance 1 is implemented with the following attributes ID Access Name 1 Get Interface Speed 2 Get Interface Flags 3 Get Physical Address Services The following services are implemented Code Class Instance Service Name Ox0E No Yes Get_Attribute_ Single
2. Local Configuration 38 60 9 2 6 Netbiter Argos This page contains settings for connecting to Netbiter Argos and shows the status of the connection Proxy Setup If you are connecting to the Internet via a proxy select the proxy type in the drop down menu Use proxy to connect to Internet and fill in the IP address the port number to use on the LAN side and if required the username and password for the proxy server Click on Save settings when finished Status Modbus Ethernet System Netbiter Argos About Netbiter Argos configuration System ID 003011FB9675 Activation code wenn Use proxy to connect to internet HTTP y Server 192 168 0 99 Port 443 Username JoeUser Password a save settings Fig 61 Netbiter Argos and proxy configuration WAN Ports The proxy server must allow traffic on at least one of the following ports e Port 443 e Port 80 e Port 5222 If none of the ports listed above are open on the WAN side the gateway will not be able to communicate with Netbiter Argos Netbiter EasyConnect Gateway User Manual Doc ID HMSI 168 92 Version 4 00 Local Configuration 39 60 9 2 7 9 2 8 Modem Settings EC250 Status Modbus Modem GPS Ethernet System Netbiter Argos About Modem Settings Pin code Press button to test enter pin code Enable test pin code modem info Fig 62 Modem settings If you
3. Netbiter EC150 EC220 Model name Netbiter EC150 Netbiter EC220 Order code NB1001 NB1000 GPRS Quad band GPRS Class 12 850 900 1800 1900 MHz max 24 V AC DC 1 A Digital inputs 2 2 isolated max 24 VDC Analog inputs Analog output 0 10 V 2 inputs PT100 0 10 V 0 20 mA Resolution 11 25 bit raw value 0 2400 Input tolerance 0 10 V R 1 55 A D 2 mV Input tolerance 4 20 mA 2 14 A D 2 mV 1 Serial port 1 RS 232 up to 115 2 kbit s RS 232 up to 115 2 kbit s Serial port 2 RS 232 RS 485 up to 115 2 kbit s RS 485 up to 115 2 kbit s isolated isolated Antenna connector SMA female Protocols Modbus RTU ASCII TCP IP Modbus RTU Connected devices 32 16 Baud rates 300 115200 baud 300 115200 baud Wall mounting Yes DIN rail mounting Dimensions WxDxH 90 x 70 x 58 mm Yes optional 92 x 115 x 25 mm Operating temperature 40 to 65 C 30 to 65 C Storage temperature 40 to 85 C 40 to 85 C Housing class IP20 IP20 Power supply 9 24 V DC or AC 9 24 V DC Power consumption 2W 2W Certifications CE ROHS CE cULus FCC IC PTCRB Netbiter EasyConnect Gateway User Manual Doc ID HMSI 168 92 Version 4 00 Technical Data 57 60 Technical Specifications Netbiter EC250 EC310 EC350 Model name Netbiter EC250 Netbiter EC310 Netbiter EC350 Order codes NB1003 NB1007 NB1005 with antenna NB1008 without antenna Eth
4. Netbiter EasyConnect Gateway User Manual Doc ID HMSI 168 92 Version 4 00 Technical Data 51 60 12 Technical Data 12 1 Dimensions O All measurements are in millimeters unless otherwise specified 12 1 1 Netbiter EC150 B 2 Z 20000 el LLOLBBLIGVETIL Q Fig 82 EC150 dimensions Netbiter EasyConnect Gateway User Manual Doc ID HMSI 168 92 Version 4 00 Technical Data 52 60 12 1 2 Netbiter EC220 B2 A LE GLL amp COL Gor Fig 83 EC220 dimensions Netbiter EasyConnect Gateway User Manual Doc ID HMSI 168 92 Version 4 00 Technical Data 53 60 12 1 3 Netbiter EC250 N AN AN O N A O N A FW WS 2929 O N A O N A O A Fig 84 EC250 dimensions Netbiter EasyConnect Gateway User Manual Doc ID HMSI 168 92 Version 4 00 Technical Data 54 60 12 1 4 Netbiter EC310 me ra a ma Fi ra ra rs a ra ro ra mu Ka Fig 85 EC310 dimensions Netbiter EasyConnect Gateway User Manual Doc ID HMSI 168 92 Version 4 00 Technical Data 55 60 12 1 5 Netbiter EC350 Stl Gal Fig 86 EC350 dimensions Netbiter EasyConnect Gateway User Manual Doc ID HMSI 168 92 Version 4 00 Technical Data 56 60 12 2 Specifications Technical Specifications
5. No connection to Netbiter Argos e Check that the mobile network provider grants access to port 5222 Running Off Contact Netbiter support Green flashing Normal operation GSM Signal Off Contact Netbiter support Green 1 flash Poor mobile network signal e Make sure the antenna is correctly installed and pointing upwards e Try a different antenna placement e Use an external antenna Green 2 flashes Acceptable mobile network signal Green 3 flashes Good mobile network signal 2 The Netbiter SIM card will automatically try to connect to a network in the global HMS home network group of op erators list of these network operators can be found at the Netbiter support website Netbiter EasyConnect Gateway User Manual Doc ID HMSI 168 92 Version 4 00 LED Indicators 22 60 4 3 Netbiter EC250 Module Status a netbi ter Serial Status Ethernet Activity Fig 28 EC250 LED indicators The Module Status LED alternates between displaying system status and mobile network signal strength for 2 seconds each in a 4 second cycle If a mobile network connection has not been set up the LED will stay unlit during the second part of the cycle LED Indication Meaning OFF No power Orange green System is starting up ca 40 seconds Red 1 flash SIM card not registered on HMS Home Network e Check that the SIM card is correctly inserted and undam aged and that P
6. xi DHCP Type MAC 10 10 13 81 10 10 13 84 10 10 13 102 10 10 13 131 10 10 13 230 10 10 13 232 10 10 13 233 255 255 255 0 255 255 255 0 255 255 255 0 255 255 255 0 255 255 255 0 255 255 255 0 255 255 255 0 10 10 13 1 10 10 13 1 10 10 13 1 10 10 13 1 10 10 13 1 10 10 13 1 10 10 13 1 00 30 11 FB 93 53 00 30 11 FB 88 75 00 30 11 FB FO B0 00 30 11 FB 5B BC 00 30 11 FB 3B 22 00 30 11 FB 90 65 00 30 11 FB 96 3D Settings Fig 52 IPconfig main window Main window columns IP IP address of the Netbiter gateway SN Subnet mask GW Default gateway DHCP Automatically managed IP configuration Version Firmware version Type Netbiter model name MAC Ethernet MAC address System ID Doc ID HMSI 168 92 Version 4 00 Ethernet Network Setup 32 60 7 2 3 Changing IP settings To change the IP settings for a unit in the list either double click on it or select it and click on Settings to open the configuration window su Configure 00 30 11 FB 94 6F 3 xi Ethernet configuration IP address Subnet mask Default gateway Primary DNS Secondary DNS Hostname Password Change password Mew password i Cancel Fig 53 IPConfig settings Notes e Donot enable DHCP if there is no DHCP server available on the network e You can add aname for the Netbiter gateway in the Hostname field Only characters a z A Z 0 9 and _ underscore are allowed e The default password fo
7. A GND 6 9 DSR Data Set Ready RTS Request To Send Fig 6 D sub connector CTS Clear To Send OO CO NII B OINI gt RI Ring Indicator 3 1 3 Ethernet Connector The RJ 45 socket provides Ethernet network connection It also supports Modbus TCP via Ethernet which can be used at the same time as Modbus RTU units on another interface Ethernet connector pin layout Pin Function WW 2 TD 3 RD 4 5 7 8 Termination 1 8 6 RD Netbiter EasyConnect Gateway User Manual Fig 7 Ethernet connector Doc ID HMSI 168 92 Version 4 00 Connections 9 60 3 2 Netbiter EC220 3 2 1 Terminal Block 12 pin Fig 8 Terminal block Terminal block pin layout Pin Function Note Vdc Power 12 24 VDC GND PE ground AO OUT Analog output 0 10 VDC AO COM Analog output common Internally connected to GND AIAI 1 Analog input 1 PT100 current or voltage selected with internal switch AL Al 2 Analog input 2 Al COM Analog input common Internally connected to GND DI DI1 Digital input 1 Low 0 1 VDC High 9 24 VDC DI DI2 Digital input 2 DI COM Digital input common Relay COM Relay output common Relay NO Normally open connected Rated load 1 24 VDC Analog Input Configuration Switches Fig 9 I pr100 0 20 mA _ 0 10v Al EC220 DIP switch The analog inputs are configured with two DIP switches inside the unit Ta
8. Green flashing Searching for mobile network Green steady Connected to mobile network Gateway Off No power or unit is starting up Red steady Hardware failure contact Netbiter support Red flashing Application failure contact Netbiter support Green flashing Firmware update in progress Green steady Unit is operational Power Off No power Green steady Netbiter EasyConnect Gateway User Manual Unit has power Doc ID HMSI 168 92 Version 4 00 LED Indicators 25 60 Press and release MODE O O netbiter RS485 ec3 50 ED RS232 ED Uplink WAN Modem q Gateway Power O K 3G GPRS RS485 RS232 A B COM x Tx GND Sass ES oe SS oe Ss O Fig 32 EC350 LED indicators and mode switch Signal Strength shown for 60 seconds when MODE switch is pressed LED indication Meaning 1 red LED flashing No unknown signal 1 orange LED flashing 1 green LED flashing 2 5 green LEDs flashing Poor mobile network signal e Make sure the antenna is correctly installed and pointing upwards e Try a different antenna placement e Use an external antenna Acceptable mobile network signal Good to optimum mobile network signal Fig 33 Ethernet Link LEDs LED Indication Meaning Off No Ethernet traffic Orange flashing Green flashing Netbiter EasyConnect Gateway User Manual Activity on 10 Mbit s network A
9. Loc Pending Telec PTCRB Pending JATE FCC IC PTCRB RCM ATEX Haz Loc Pending Netbiter EasyConnect Gateway User Manual Doc ID HMSI 168 92 Version 4 00 Technical Data 58 60 12 3 12 3 1 12 3 2 12 3 3 Regulatory notices FCC Compliance Statement The design of this equipment complies with U S Federal Communications Commission FCC guidelines respecting safety levels of radio frequency RF exposure for Mobile devices This product contains FCC ID QIPPHS8 P RF Exposure This device is only authorized for use in a mobile application At least 20 cm of separation distance between the device and the user s body must be maintained at all times AB could void the user s authority to operate the equipment This equipment has been tested and found to comply with the limits for a Class A dig ital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio fre quency energy and if not installed and used in accordance with the instruction man ual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Any changes or modific
10. are using a SIM card with PIN code security activated click on Enable and enter the PIN code provided by the card supplier To test the PIN code click on Test PIN This setting will not enable disable PIN code security or change the PIN code on the SIM card To do that install the SIM card in a mobile phone and follow the instruc tions from the manufacturer GPRS Ethernet Failover Settings GPRS Ethernet failover Settings Connection mode Ethernet failover to GPRS Connection time before restore to Ethernet Try Ethernet after 8 hour y Try Ethernet after 30 min Access point name APN intellicom apn teler Try Ethernet after 2 hour Try Ethernet after 8 hour User name Try Ethernet when GPRS fails Password save settings Fig 63 GPRS Ethernet failover settings Netbiter EC250 can be set to temporarily switch to mobile networking if Ethernet fails Connection mode GPRS only Ethernet disabled default mode Ethernet failover to GPRS Unit will automatically switch to GPRS if Ethernet connection is lost Ethernet only GPRS modem disabled Connection time before Sets the time before the gateway should retry the Ethernet connection after a restore to Ethernet failover to GPRS The cycle will be repeated until Ethernet communication has been reestablished Access point name The identifying name used to connect to a mobile network This information is APN supplied by the netw
11. card into the holder Observe the correct position of the cut off corner and the contact surfaces 3 Insert the SIM card holder with the SIM card SIM Card configuration The SIM card must be configured in Netbiter Argos before it can be used When using a SIM card not issued by HMS make sure that the SIM card has a mobile data plan and allows text messaging and that PIN code security has been disabled See the Netbiter Argos Administration Manual for further information Netbiter EasyConnect Gateway User Manual Doc ID HMSI 168 92 Version 4 00 Connections 12 60 3 3 Netbiter EC250 3 3 1 Terminal Block 12 pin Fig 12 Terminal block Terminal block pin layout Pin Label Function Note 24 Vs 23 GND PE ground 22 DI COM Digital input common 21 DI DI1 Digital input 1 Low 0 2 VDC High 10 24 VDC 20 DI DI2 Digital input 2 Low 0 2 VDC High 10 24 VDC 19 RS 202 RX 18 RS 232TX 17 COM Shared between RS232 422 485 16 RS 422 RD A 15 RS 422 RD B RS 422 Receive B 14 RS 485 TD A RS 485 Line RS 422 TD A RS 422 Transmit A 13 RS 485 TD B RS 485 Line B RS 422 TD B RS 422 Transmit B 3 3 2 D sub Connector The 9 pin D sub connector provides an RS 232 interface for Modbus RTU and for connect ing a GPS receiver D sub connector pin layout Pin 1 male 5 Function CD Carrier Detect Rx Receive Tx Transmit DTR Data Terminal Re
12. result from the use of undocumented features timing or functional side effects found outside the documented scope of this product The effects caused by any direct or indirect use of such aspects of the product are undefined and may include e g compatibility issues and stability issues The examples and illustrations in this document are included solely for illustrative purposes Because of the many variables and requirements associated with any particular implementation HMS Industrial Networks AB cannot as sume responsibility for actual use based on these examples and illustrations Intellectual Property Rights HMS Industrial Networks AB has intellectual property rights relating to technology embodied in the product de scribed in this document These intellectual property rights may include patents and pending patent applications in the USA and other countries Trademark Acknowledgements Netbiter is a registered trademark of HMS Industrial Networks AB Java is a registered trademark of Oracle and or its affiliates All other trademarks are the property of their respective holders This is a class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures trol procedures are not followed Static control precautions are required when handling the product n This product contains ESD Electrostatic Discharge sensitive parts that may be damage
13. 2552550 1010131 33 00 30 11 FB 93 53 101013119 2552552550 1010131 04 00 30 11 FB FO DO 101013120 255 255 255 0 04 00 30 11 FB FE E2 255 255 255 0 00 30 11 FB F9 C2 255 255 255 0 Configuration 255 255 255 0 10 13 00 30 11 FB F1 7C 255 255 2550 0 0 0 Open Web Interface 00 30 11 FB 3B 22 255 255 255 0 0 0 0 Wink 00 30 11 FB 8F 2D 10 13 255 255 255 0 10 13 RE 00 30 11 FB 90 65 10 10 13 233 255 255 255 0 Off 1331 EC250 00 30 11 FB 96 3D 10 10 13 235 255 255 255 0 Off 1031 EC350 00 30 11 FB F1 88 Settings Exit Fig 55 IPconfig Netbiter EC310 and EC350 also have a USB port that can be used for accessing the local web server see Select Login Method p 40 Netbiter EasyConnect Gateway User Manual Doc ID HMSI 168 92 Version 4 00 Local Configuration 35 60 9 2 9 2 1 9 2 2 Netbiter EC150 EC250 Login Enter the IP address of the gateway in a web browser to log in The default user name is admin and the password is the activation code supplied with the unit EasyConnect netbi ter i EC150 Device ID 003011FBS5BBC Fig 56 Local web server login The only changes that should be made locally are the settings for the network connection modem settings EC250 and firmware updates All other settings are provided for trou bleshooting and information purposes only and will not be synchronized with Netbiter Argos Status The Status page presents an overview of the current conn
14. IN security is disabled e Check that there is mobile network coverage for your operator Red 2 flashes Invalid network settings Mobile e Check that the correct APN Access Point Name has been set in Netbiter Argos Ethernet Module Status 1 DHCP Check that there is a working DHCP server on the network e Static IP Check that the IP address default gateway and DNS are correctly set e Ifa proxy is used check that the proxy settings are correct Red 3 flashes No connection to Netbiter Argos Mobile e Check that the mobile network provider grants access to port 5222 Ethernet e Check the network settings e Ifa proxy is used check that the proxy settings are correct e Check that at least one of ports 443 80 or 5222 are open in the firewall Green 1 flash Poor mobile network signal e Make sure the antenna is correctly installed and pointing upwards Module Status 2 e Try a different antenna placement e Use an external antenna Green 2 flashes Acceptable mobile network signal Green 3 flashes Good mobile network signal Steady orange System is starting up Serial Status Flashing green Receiving serial packet Flashing red Transmitting serial packet Ethernet Activity Flashing green Receiving Ethernet packet a Steady green 10 Mbps Ethernet network detected thernet Lin Steady orange 100 Mbps Ethernet network detected 3 The Netbiter SIM card will automatically try to connect to a network in the global HMS home ne
15. LAN Modem Uplink Rececesscees DEN No Fig 68 Status LAN Sh Network settings Modem settings Firmware update Logs Data Connection About IP Netmask APN Signal quality Overview WAN LAN Uplink Yes 10 46 66 61 299 255 255 255 intellicom apn telenor se OUUU 14131 Fig 69 Status Modem Status Network settings Modem settings Firmware update Logs Default route About Default gateway DNS 1 DNS 2 geneve neneve ve oreve ves s ues Overview WAN LAN Modem Uplink E Modem 10 64 64 64 193 181 246 57 193 181 246 58 Fig 70 Status Uplink Netbiter EasyConnect Gateway User Manual Doc ID HMSI 168 92 Version 4 00 Local Configuration 42 60 9 3 4 Network Settings WAN S tatus WAN LA N Network settings Modem settings Y Enable WAN interface Firmware update ous 4 Use DHCP to assign an IP address automatically About IP address assigned to 10 10 50 158 the system N o Netmask 255 255 255 Gateway 10 10 50 1 Primary DNS 10 10 100 88 Secondary DNS 10 10 100 87 Fig 71 WAN settings The WAN interface should be enabled when connecting to Netbiter Argos via Ethernet The settings are the same as those entered in IPconfig see IP Configuration p 31 When DHCP is enabled the unit will automatically receive the settings for IP address sub net mask default gateway and DNS Contact your network a
16. Local configuration is normally not required and should only be carried out when nec essary Please read the instructions below carefully All Netbiter EasyConnect gateways except EC220 contain a built in local web server that can be used for initial configuration and troubleshooting Netbiter Argos is the preferred way of configurating the gateway and should be used whenever possible The only settings that should be made using the local web pages are e Proxy settings if required e Modem Ethernet connection mode EC250 EC350 only e PIN code settings if using a PIN code for the SIM card EC250 only Connecting to the Web Server The PC used to access the local configuration must be on the same Ethernet network sub net as the gateway The PC can also be connected directly to the gateway using a crossover Ethernet cable This may require the IP address for the Ethernet interface on the PC to be changed To connect to the web server in the Netbiter gateway use the IPconfig utility to detect the IP address of the gateway see IP Configuration p 31 Right click on the gateway in IPconfig and select Open Web Interface to open its local web server in your default browser You can also type the IP address directly into the web browser address field rm F Tron IP SN ew HCP Version Type mac 10101354 2552552550 1010131 1320 EC250 00 30 11 FB 96 75 10101378 2552552550 1010131 1022 EC350 00 20 11 FB F3 A8 10101381 255
17. Manual for further information Netbiter EasyConnect Gateway User Manual Doc ID HMSI 168 92 Version 4 00 Connections 15 60 3 4 Netbiter EC310 EC350 3 4 1 Terminal Block 11 pin an oa FB FB SF Bee fe SANGASAPAAQA DT SSeS naloa pa D P af 3 Fig 15 Terminal block Terminal block pin layout Pin Label Function Note 11 COM Analog Input Common 10 Al4 Analog Input 4 0 20 mA or 0 10 VDC 9 8 AI3 Analog Input 3 0 20 mA or 0 10 VDC or PT100 8 z JA Analog Input 2 0 20 mA or 0 10 VDC T Al1 Analog Input 1 0 20 mA or 0 10 VDC or PT100 6 c DI2 Digital Input 2 5 D DI2 Digital Input 2 current source 3 Dry contact type 4 a DI Digital Input 1 3 A px Digital Input 1 current source 2 COM Relay output common isolated gt 1 2 NO Relay output NO isolated Rated load 1 A 24 VDC X The analog inputs can be configured in Netbiter Argos for either current voltage or PT100 temperature sensor The digital inputs are of the dry contact type which do not require any control voltage and will function with a switch or breaker AN Do not connect a power source to the digital inputs as this may damage the unit The relay output must be supplied from an isolating transformer using a secondary listed fuse rated at maximum 3 3 A and minimum 30 VDC Netbiter EasyConnect Gatevvay User Manual Doc ID HMSI 168 92 Version 4 00 Connectio
18. address of the gateway in a web browser to log in The default user name is admin and the password is the activation code supplied with the unit Authentication Required O A username and password are being requested by http 10 10 13 93 The site says Password protected area User Name Password Cancel Fig 65 Local configuration web server login The only changes that should be made locally are the settings for the network connection modem settings and firmware updates All other settings are provided for troubleshoot ing and informational purposes only and will not be synchronized with Netbiter Argos Netbiter EasyConnect Gateway User Manual Doc ID HMSI 168 92 Version 4 00 Local Configuration 41 60 9 3 3 Status The Status tabs present the current configuration and connection status Status Network settings Modem settings Firmware update Logs Netbiter Argos About Connection System ID Serial number System time Overview WAN LAN Modem Uplink Connected Modem 3G 003011FBFEE2 C0118B76 2015 09 14 06 47 UTC Fig 66 Status Overview Status Network settings eens i Modem settings Firmware update Logs Enabled About DHCP IP Netmask Overview WAN LAN Modem Uplink Yes Yes 10 10 13 120 255 255 255 0 Fig 67 Status WAN Status Modem settings Firmware update Logs Enabled About Network settings pese Overview WAN
19. ady eg ee GND 6 9 DSR Data Set Ready RTS Request To Send Fig 13 D sub connector CTS Clear To Send OO MOI NII B Ww NY gt RI Ring Indicator Netbiter EasyConnect Gateway User Manual Doc ID HMSI 168 92 Version 4 00 Connections 13 60 3 3 3 Ethernet Connector The RJ 45 socket provides Ethernet network connection It also supports Modbus TCP via Ethernet which can be used at the same time as Modbus RTU units on another interface Ethernet connector pin layout Pin Function 1 TD 2 TD 3 RD 4 5 7 8 Termination 1 8 6 RD Fig 14 Ethernet connector 3 3 4 Antenna Connector The antenna connector is a standard SMA screw connector Optional external antennas are available from your supplier Netbiter EasyConnect Gateway User Manual Doc ID HMSI 168 92 Version 4 00 Connections 14 60 3 3 5 SIM Card Installing the SIM Card 1 Push the yellow button next to the SIM card holder and remove the holder 2 Place the SIM card into the holder Observe the correct position of the cut off corner and the contact surfaces 3 Insert the SIM card holder with the SIM card SIM Card configuration The SIM card must be configured in Netbiter Argos before it can be used When using a SIM card not issued by HMS make sure that the SIM card has a mobile data plan and allows text messaging and that PIN code security has been disabled See the Netbiter Argos Administration
20. atic IP addressing the network settings are configured using the IPconfig utility See IP Configuration p 31 When using DHCP the default setting there is no need to configure any of the IP ad dress related settings If the network uses a proxy to connect to the Internet you also need to set up the proxy configuration in the local configuration web interface See Local Configuration p 34 Netbiter EasyConnect Gateway User Manual Doc ID HMSI 168 92 Version 4 00 Ethernet Network Setup 31 60 7 2 7 2 1 7 2 2 Netbiter EasyConnect Gateway User Manual IP Configuration Installing the IPconfig Utility IPconfig is a Windows based configuration utility for TCP IP network settings in Netbiter gateways It detects connected Netbiter gateways and lets the user set the IP address net mask default gateway DNS and hostname for each unit 1 Download IPConfig from www netbiter com support 2 Extract the contents of the zip archive in a folder on your computer and double click the executable file to run it Scanning for Connected Devices Make sure that the Netbiter gateways to be installed are connected on the same Ethernet subnet as the computer running IPconfig Use standard Ethernet cables When the IPconfig utility is started it will scan the Ethernet network for Netbiter gate ways All detected units will be presented in a list in the main window To refresh the list click on Scan IPconfiq 10
21. ations not expressly approved by HMS Industrial Networks Industry Canada Statement This product contains IC ID 7380A PHS8P Netbiter EC350 Telecommunications Compliance Japanese Radio Law and Japanese Telecommunicatons Business Law Compliance This device is granted pursuant to the Japanese Radio Law BEE and the Japanese Telecommunications Business Law E IES SSS This device should not be modified otherwise the granted designation number will become invalid Fig 87 Telecommunications Compliance Statement Netbiter EasyConnect Gateway User Manual Doc ID HMSI 168 92 Version 4 00 This page intentionally left blank R229 2015 09 17 09 08 UTC 2015 HMS Industrial Networks AB
22. correctly set e Ifa proxy is used check that the proxy settings are correct No connection to Netbiter Argos e Check the network settings e Ifa proxy is used check that the proxy settings are correct e Check that at least one of ports 443 80 or 5222 are open in the firewall Serial Link Status Activity Collision Flashing green Receiving serial packet Flashing red Flashing green Transmitting serial packet Receiving Ethernet packet Flashing red Ethernet collision Link Steady green Steady orange 100 Mbps Ethernet network detected Netbiter EasyConnect Gateway User Manual 10 Mbps Ethernet network detected Doc ID HMSI 168 92 Version 4 00 LED Indicators 21 60 4 2 Netbiter EC220 All LED indicators will be lit while the gateway is starting up After the startup sequence has completed they will indicate system status netbiter Power Status Running GSM Signal Fig 27 EC220 LED indicators LED Indication Meaning Power Off No power Green steady Unit has power Status Off Normal operation Red 1 flash SIM card not registered on HMS Home Network e Check that the SIM card is correctly inserted and undamaged and that PIN security is disabled e Check that there is mobile network coverage for your operator Red 2 flashes Invalid network settings e Check that the correct APN Access Point Name has been set in Netbiter Argos Red 3 flashes
23. ctivity on 100 Mbit s network Doc ID HMSI 168 92 Version 4 00 Wiring Examples 26 60 9 VViring Examples 5 1 Netbiter EC150 EC250 EC150 EC250 O DI DI 1 2 9 24 VDC O _0 0 VDC O Fig 34 Digital Input 5 2 Netbiter EC220 EC220 O O ALAI 1 2 PT100 0 O Al COM 0 10 V Fig 35 Analog Input Voltage Sensor EC220 O ALAI 1 2 PT100 0 20 mA 0 10 V Fig 36 Analog Input 2 wire Current Sensor EC220 O O ALAI 1 2 PT100 0 0 20 mA 0 20 mA O Al COM 0 10 V Fig 37 Analog input 3 vvire Current Sensor EC220 O ALAI 1 2 PT100 0 20 mA 0 10 V Fig 38 Analog Input 4 wire Current Sensor EC220 O ALAI 1 2 PT100 0 20 mA 0 10 V Fig 39 Analog Input Temperature Sensor Netbiter EasyConnect Gateway User Manual Doc ID HMSI 168 92 Version 4 00 Wiring Examples 27 60 EC220 9 24 VDC O O O DI DI 1 2 0 VDC O Fig 40 Digital Input Analog load 0 10 V Max load resistance 2 kO Fig 41 Analog Output EC220 24 V DC AC O Relay NO OV Relay COM Fig 42 Relay Output The relay output must be supplied from an isolating transformer using a secondary listed fuse rated at maximum 3 3 A and minimum 30 VDC 5 3 Netbiter EC310 EC350 EC310 EC350 Q Analog In Al1 Al2 3 4 O O Analog In COM Fig 43 Analog Input Voltage Sensor EC310 EC350 Q Analog In Al1 Al2 3 4 Q Analog I
24. d if ESD con Failure to observe this may cause damage to the product Copyright 2015 HMS Industrial Networks AB All rights reserved Netbiter EasyConnect Gateway User Manual Doc ID HMSI 168 92 Version 4 00 Table of Contents Page O ay sere eee ree 3 Teds ABOUUTDIS Doumer 3 VZ REA DEMENS eies 3 kr POETEN ea ve Se 3 14 CONVENIOS a a ENES 4 2 INStalla AA 5 Zi Nebe EG OO EC2I0 a oa 5 2 2 Netbiter EC220 EC310 and EC 350 psi ii 6 3 CONNECUONS ua 7 3 1 N SE Nr une 7 32 NISE QZ ZO sp 9 Ory NEPI EC ZO 12 34 NEDE EG STI ECI isidro desert teens as 15 9 09 Pole SUI rt 19 Br LED SN 20 4 1 Netbiter EC 10 acosa Sn 20 de NE O matos irc tt a ei anse sous 21 Dot NAD EE S A 22 WA NEDE Tusen 23 AO Nebe EE SOO uns erste 24 9 WINO BAMPIES saa 26 SA NEDE EG ISO EG 50 uer 26 94 NENNE NST 26 39 NebREGSTVE SNL aa 27 0 PNL NN 29 ok CORMECING GPS DeVICCS a 29 6 2 Aciv ing the GPS TUNCHOM iii Ge 29 7 Ethernet Network Setup sind 30 Ta Static Dynamic IP Addressing gg rua shes ii 30 12 WP COMMUNAL ON n sasie dete eterna Sede 31 9 ACUVALION 2 33 8 1 Adding the Gateway to Netbiter Argos VV 33 Netbiter EasyConnect Gateway User Manual Doc ID HMSI 168 92 Version 4 00 Table of Contents 9 JOGA CON OUT AU OND riada 34 9 1 Connecting to the Web Server 8 edh dos 34 92 Netbiter EC1S50 E C250 se 35 9 3 N tbie ECS TI0 ECS50 lll 40 10 Netbiter Update EC150 EC250 rrrnnnvrrernnnnnnnnennnnnnnevnnnnnn
25. dministrator if in doubt Proxy Settings Y Enable Proxy settings Proxy IP address 192 168 0 99 Proxy port 443 4 Proxy protocol HTTP Username JoeUser Password zX58xjuop Save settings Don t save settings Fig 72 Proxy settings If you are connecting to the Internet via a proxy check the box Enable Proxy settings se lect the proxy type in the drop down menu Proxy protocol and fill in the IP address and the port number to use for the proxy server If the proxy requires authentication check the box Use Proxy authentication and fill in the username and password Click on Save settings when finished For information about the supported proxy types see Specifications p 56 Netbiter EasyConnect Gateway User Manual Doc ID HMSI 168 92 Version 4 00 Local Configuration 43 60 9 3 5 Network Settings LAN The LAN interface must be enabled when using EtherNet IP or Modbus TCP applications and when using the Netbiter Remote Access service These settings can also be made in Netbiter Argos See the Netbiter Argos Administration Manual Status WAN LAN Network settings Modem settings Y Enable LAN interface Firmware update E Use DHCP to assign an IP address automatically About IP address assigned to 192 168 1 100 the system Netmask 255 255 255 0 Save settings Don t save settings Fig 73 LAN settings AN Do not connect the LAN and WAN ports to the same logical net
26. ection status Connects on ethernet fail Modem connection status Netbiter Argos status Connected to server GPS status Not installed Fig 57 Status page Netbiter EasyConnect Gateway User Manual Doc ID HMSI 168 92 Version 4 00 Local Configuration 36 60 9 2 3 Modbus Settings Settings for Modbus communication These settings should normally be made in Netbiter Argos See the Netbiter Argos Administration Manual for more information Transmission Mode Slave Response Timeout Physical interface RS 485 Baudrate 9600 bps Character Format No Parity 1 Stop Bit Extra delay between messages ms Character delimiter 0 Standard modbus 3 5 Chars ms 0 Use function code 15 when writing single bits coils Disable Use function code 16 when writing single registers Disable Transparent Modbus TCP to Modbus RTU Disable mw Port number 502 Internal module registers via Modbus TCP Enable Modbus Slave Address a Server Idle Timeout Enable JI Seconds 60 IP Authentication Enable IP Number Mask No Modbus slaves found Fig 58 Modbus Settings 9 2 4 Ethernet Settings Status Modbus Ethernet System Netbiter Argos About DHCP t DynamicIP Static IP Host Name IP Address Subnet mask Gateway Primary DNS Sec
27. ernet 10 100 Mbit s 10 100 Mbit s Proxy support N A SOCKS authentication none username password WEB authentication none basic Mobile communication Quad band GPRS N A 5 band 3G UMTS Class 12 WCDMA FDD 850 900 1800 1900 MHz 800 850 900 1900 2100 MHz Quad band GSM GPRS 850 900 1800 1900 MHz Alarms Email SMS Email SMS Relay output N A 1 max 24V AC DC 1A Digital inputs 2 isolated max 24 VDC 2 dry contact type Analog inputs N A 4 inputs all supporting 0 10 V or 0 20 mA Current 0 20 mA R 3 3 A D 0 1 mV 0 15 Voltage 0 10 VDC R 1 7 A D 0 1 mV 0 15 Support for PT100 on Al1 and Al3 Sensor range 50 to 150 C 16 bit resolution Serial port 1 Serial port 2 RS 232 up to 115 2 kbit s RS 485 up to 115 2 kbit s RS 232 up to 115 2 kbit s RS 485 up to 115 2 kbit s Antenna connector SMA female N A SMA female Protocols Modbus RTU ASCII TCP Modbus RTU Modbus TCP EtherNet IP Connected devices 32 32 Baud rates 300 115200 baud 1200 115200 baud Wall mounting No Yes DIN rail mounting Yes Yes optional Dimensions WxDxH 90 x 70x58 mm 135 x 92 x 27 mm Operating temperature 30 to 65 C 40 to 65 C Storage temperature 40 to 85 C 45 to 85 C Housing class IP20 IP20 Power supply 9 24 VDC 12 48 VDC Power consumption 3 W 4 5 W typical 6 W maximum Certifications CE CE CE RoHS RoHS RoHS cULus cULus cULus FCC IC Pending ATEX Haz
28. ersion 4 00 Connections 19 60 3 5 Power Supply Always make sure that the power supply is correctly connected and of the correct type Connecting power with reverse polarity or using the wrong type of power supply may damage the unit Netbiter EC150 and EC250 Fig 23 EC150 EC250 power supply connection Connect 9 24 VDC to Vin EC150 or V EC250 and connect ground to GND O Netbiter EC150 can alternatively be powered by 9 24 VAC Netbiter EC220 Fig 24 EC220 power supply connection Connect 9 24 VDC to VDC and connect ground to GND Netbiter EC310 and EC350 u JSf w 2 DUFF IO DO E LA Es NS E E O 5S LOLS Saag H60 6 0 Z Analog In Di Pulse In Relay Power 12 48 VDC Fig 25 EC310 EC350 power supply connection Connect 12 48 VDC to plus and connect ground to minus Netbiter EasyConnect Gateway User Manual Doc ID HMSI 168 92 Version 4 00 LED Indicators 20 60 4 LED Indicators 4 1 Netbiter EC150 netbiter Fig 26 EC150 LED indicators Module Status amp Serial Link Status LED Indication Module Status OFF Meaning No power Orange green System is starting up Green 3 flashes System is operating normally Red 2 flashes Red 3 flashes Invalid network settings e DHCP Check that there is a working DHCP server on the network e Static IP Check that the IP address default gateway and DNS are
29. info on relay in EC150 2 11 April 2014 Minor correction to dimensions Added Japanese approval information 2 20 May 2014 Added EC310 Updated LEDs for EC350 2 30 September 2014 SDa Certifications updated for EC310 EC350 2 40 November 2014 SDa Added EtherNet IP support Updated specs for EC3xx 2 50 December 2014 TAN Changed tolerance values 3 00 May 2015 TAN Multiple corrections and updates Revised document structure and layout 3 10 June 2015 TAN Added info on symbolic segment addressing 4 00 Sep 2015 TAN Misc corrections and updates New layout Netbiter EasyConnect Gateway User Manual Doc ID HMSI 168 92 Version 4 00 Preface 4 60 1 4 Conventions Unordered bulleted lists are used for e Itemized information e Instructions that can be carried out in any order Ordered numbered or alphabetized lists are used for instructions that must be carried out in sequence 1 First do this 2 Then open this dialog and a set this option b and then this one Bold typeface indicates interactible parts such as connectors and switches on the hard ware or menus and buttons in a graphical user interface Monospaced text is used to indicate program code and other kinds of data input output such as configuration scripts This is a cross reference within this document Conventions p 4 This is an external link URL www hms networks com O This is additional information which may facilitate installa
30. ion 4 00 LED Indicators 24 60 4 5 Netbiter EC350 All LED indicators will light up while the gateway is starting up After the startup se quence has completed they will indicate system status Pressing and releasing the MODE button will temporarily change the function of the top 5 LED indicators to show the strength of the mobile network signal After 60 seconds the indicators will revert to the default mode system status Fig 31 RS485 GD RS232 netbiter ec350 ED Uplink WAN ED Modem Gateway ED Power EC350 LED indicators System Status default mode LED Indication Meaning RS485 RS232 Off Port not in use Red steady Port failure contact Netbiter support Green steady Port enabled in Netbiter Argos Uplink WAN Red steady Incorrect IP address settings e DHCP Check for a working DHCP server on the network e Static IP Check that the IP address default gateway and DNS are correctly set Red flashing No connection to Netbiter Argos e Check your network settings e Check that port 443 is open in the firewall Green steady Connected to Netbiter Argos Modem Off Modem disabled Red steady Modem failure contact Netbiter support Red flashing SIM card failure e Check that the SIM card is correctly inserted and undamaged Orange steady PIN code is activated for the SIM card e Disable the PIN code on the SIM card Orange flashing APN Access Point Name not set
31. ke care not to damage the antenna cable when opening closing the cover EC220 DIP switch setting Setting Function Note PT100 Temperature sensor default 50 to 150 C 0 20 mA Current Input resistance 270 Q 0 10 VDC Voltage Input resistance 280 Q Netbiter EasyConnect Gateway User Manual Doc ID HMSI 168 92 Version 4 00 Connections 10 60 3 2 2 RS 485 Serial Interface 3 pin Connector The RS 485 serial interface can be used to connect Modbus RTU devices Fig 10 RS 485 connector RS 485 connector pin layout Pin Function A RS 485 A line B RS 485 B line COM RS 485 common 3 2 3 D sub Connector The 9 pin female D sub connector provides an RS 232 interface for Modbus RTU and for connecting a GPS receiver D sub connector pin layout 5 female 1 U 5 Function CD Carrier Detect Rx Receive Tx Transmit DTR Data Terminal Ready GND 9 6 DSR Data Set Ready RTS Request To Send Fig 11 D sub connector CTS Clear To Send RI Ring Indicator OI MH B WwW DN gt 3 2 4 Antenna Connector The antenna connector is a standard SMA screw connector Optional external antennas are available from your supplier Netbiter EasyConnect Gateway User Manual Doc ID HMSI 168 92 Version 4 00 Connections 11 60 3 2 5 SIM Card Installing the SIM Card 1 Push the yellow button next to the SIM card holder and remove the holder 2 Place the SIM
32. licom Innovation AB Fig 80 Updating in process 9 When the update is finished you will be prompted to reboot the Netbiter gateway Click on Yes to reboot Fig 81 Reboot the Netbiter gateway Netbiter EasyConnect Gateway User Manual Doc ID HMSI 168 92 Version 4 00 EtherNet IP Implementation 48 60 11 EtherNet IP Implementation See also the Netbiter Argos Administration Manual on how to configure EtherNet IP 11 1 Client Connection Type UCMM Class 1 and 3 connection not supported Adapter Timeout 1000 ms Services The following services are implemented Addressing Note Class Instance Attribute Class Instance Attribute Code Service Name Ox0E Get Attribute_Single 0x10 Set Attribute Single Ox4C Read_Tag_Service 0x4D VVrite Tag Service Symbolic Segment Can be used to access Controller Tags Addressing Vendor specific service code see note below Read_Tag_Service and Write_Tag_Service using symbolic segment addressing is only supported by some Rockwell PLC s Please refer to the documentation for the specific PLC for more information Netbiter EasyConnect Gateway User Manual Doc ID HMSI 168 92 Version 4 00 EtherNet IP Implementation 49 60 11 2 11 2 1 11 2 2 Adapter Identity Object 0x01 Class Attributes No attributes are implemented Instances Instance 1 is implemented with the following attributes
33. n COM EC3101 EC350 Q Analog In Al1 A12 3 4 0 20 mA O Q Analog In COM Fig 45 Analog input 3 wire Current Sensor Netbiter EasyConnect Gateway User Manual Doc ID HMSI 168 92 Version 4 00 Wiring Examples 28 60 EC310 EC350 Analog In Al1 AI2 3 4 Q Analog In COM Fig 46 Analog Input 4 wire Current Sensor EC310 EC350 Fig 47 EC310 EC350 O DI Pulse In DI1 DI2 O DI Pulse In DI1 DI2 Fig 48 Digital Input Do not connect a power source to the digital inputs on a Netbiter EC310 EC350 as this may damage the unit EC310 EC350 24 VDC AC O Relay NO Relay COM Fig 49 Relay Output The relay output must be supplied from an isolating transformer using a secondary listed fuse rated at maximum 3 3 A and minimum 30 VDC Netbiter EasyConnect Gateway User Manual Doc ID HMSI 168 92 Version 4 00 GPS 29 60 6 1 6 1 1 6 2 GPS Connecting GPS Devices Netbiter EC220 Connecting a GPS device to a Netbiter EC220 requires a cable with a 9 pin male D sub connector to connect to the RS 232 port 1 male 5 It K IT K domene i 6 9 Fig 50 D sub connector GPS cable pin assignment EC220 RS 232 port GPS device 2 Rx Receive Tx 3 Tx Transmit Rx 5 GND GND Netbiter EC250 Connecting a GPS device to a Netbiter EC250 requires a cable with a 9 pin female D sub connector
34. n t save settings Fig 75 Modem settings EC350 Use modem as primary When enabled mobile networking will be used as default as long as the signal connection to Argos strength is adequate If the WAN interface is also enabled the gateway will automatically switch to Ethernet networking if mobile communication is interrupted APN The APN Access Point Name is the identifier for the mobile network The APN is supplied by the network operator for the SIM card User Password Required by some mobile network operators Click on Save settings when finished SIM cards with active PIN code security cannot be used in Netbiter EC350 The PIN code cannot be disabled here or in Netbiter Argos Install the SIM card in a mobile phone and follow the instructions from the manufacturer to disable the PIN code Netbiter EasyConnect Gateway User Manual Doc ID HMSI 168 92 Version 4 00 Netbiter Update EC150 EC250 45 60 10 Netbiter Update EC150 EC250 The easiest way to update firmware is via Netbiter Argos with the local configuration pa ges as a backup option if Netbiter Argos cannot be used The firmware for Netbiter EC150 and EC250 can also be uploaded via the RS 232 serial D sub interface using a free Win dows based software tool Netbiter Update Updating Firmware with Netbiter Update Requirements e Null modem cable e Computer with RS 232 serial interface COM port 1 Download Netbiter Update from www netbiter com sup
35. netbiter USER MANUAL Netbiter EasyConnect Gateway Doc ID HMSI 168 92 Version 4 00 17 AmS Connecting Devices 77 HALMSTAD CHICAGO KARLSRUHE TOKYO BEIJING MILANO MULHOUSE COVENTRY PUNE COPENHAGEN RAVENSBURG HMS Industrial Networks Mailing address Box 4126 300 04 Halmstad Sweden E mail info hms networks com Visiting address Stationsgatan 37 Halmstad Sweden Web www netbiter com Important User Information Liability Every care has been taken in the preparation of this manual Please inform HMS Industrial Networks AB of any in accuracies or omissions The data and illustrations found in this document are not binding We HMS Industrial Net works AB reserve the right to modify our products in line with our policy of continuous product development The information in this document is subject to change without notice and should not be considered as a commitment by HMS Industrial Networks AB HMS Industrial Networks AB assumes no responsibility for any errors that may ap pear in this document There are many applications of this product Those responsible for the use of this device must ensure that all the necessary steps have been taken to verify that the applications meet all performance and safety requirements in cluding any applicable laws regulations codes and standards HMS Industrial Networks AB will under no circumstances assume liability or responsibility for any problems that may arise as a
36. nnenennnnnnnennsnnnnnnennennnnnnnenennn 45 11 EtherNet IP Implementation sins nnmnnn 48 Tek GENRE 48 V2 PEN NAPP 49 12 ISO CAP Al 51 121 DIMENSION pas 51 122 A A A 56 129 Regulator NOCES aS 58 Netbiter EasyConnect Gateway User Manual Doc ID HMSI 168 92 Version 4 00 Preface 3 60 1 2 1 3 Preface About This Document This manual describes how to install and configure Netbiter EasyConnect gateways For additional related documentation and file downloads please visit the Netbiter sup port website at www netbiter com support Related Documents Related documents Document Author Netbiter EasyConnect Gateway Installation Guides HMS Netbiter Argos Administration Manual HMS Netbiter Remote Access User Manual HMS Document history Summary of recent changes Change Where section no Updated section on EC350 LED indicators 4 5 Replaced D sub graphic for EC220 mend Changed physical network to logical network 3 4 4 9 3 5 Updated IP configuration section 7 2 Updated local configuration section 9 Updated class attribute descriptions 11 22 Added info about proxy support 12 2 Updated screenshots in most sections Revision list Version Date Author Description 1 00 Nov 2012 First official release 1 10 Mar 2013 New chapter on Ethernet installation 2 00 November 2013 Added EC350 2 10 January 2014 Removed EC150 M Removed
37. ns 16 60 3 4 2 RS 485 Serial Interface 3 pin connector The RS 485 serial interface can be used to connect Modbus RTU devices Fig 16 RS 485 connector RS 485 connector pin layout Pin Function A RS 485 A line B RS 485 B line COM RS 485 common 3 4 3 RS 232 Serial Interface 3 pin connector The RS 232 serial interface can be used to connect a single Modbus RTU device Rx Tx GND Fig 17 RS 232 connector RS 232 connector pin layout Pin Function Rx Receive input Tx Transmit output GND Signal ground Netbiter EasyConnect Gateway User Manual Doc ID HMSI 168 92 Version 4 00 Connections 17 60 3 4 4 Ethernet Ports RJ 45 Fig 18 Ethernet Ports WAN Used for connecting to the Internet and Netbiter Argos LAN Used for EtherNet IP Modbus TCP and Remote Access Ethernet connector pin layout Pin Function 1 TD 2 TD 3 RD 4 5 7 8 Termination q 8 6 RD Fig 19 Ethernet connector 3 4 5 USB Connector The USB connector can be used to connect locally to the Netbiter EC310 350 for firmware upgrades configuration and troubleshooting See also Select Login Method p 40 Fig 20 USBconnector Netbiter EasyConnect Gateway User Manual Doc ID HMSI 168 92 Version 4 00 Connections 18 60 3 4 6 3 4 7 3G GPRS and GPS Antenna Connectors EC350 The 3G GPRS antenna connector on the front of the Ne
38. ondary DNS Fig 59 Ethernet settings These are the same settings as those entered in IPconfig see IP Configuration p 31 When DHCP is enabled the unit will automatically receive the settings for IP address sub net mask default gateway and DNS Contact your network administrator if in doubt Netbiter EasyConnect Gateway User Manual Doc ID HMSI 168 92 Version 4 00 Local Configuration 37 60 9 2 5 System Settings Status Modbus Ethernet System Netbiter Argos About Firmware Select an update file nbu or nbp Browse_ No file selected update Name Version Information Kernel version 1 2 26 Application version 1 31 0 build 314 Tools Get system log files save Restart module reboot Reset to factory default settings reset User interface FE English ha Password Change password 7 Repeat password save Fig 60 System settings This page is mainly used when updating the firmware in the unit Updating Firmware 1 Download the latest firmware from www netbiter com support 2 Click on Browse and select the firmware file you downloaded 3 Click on Update to start the update AN Do not close the web page while the update is in progress The firmware in Netbiter EC150 and EC250 can alternately be uploaded via the RS 232 se rial interface See Netbiter Update EC150 EC250 p 45 Netbiter EasyConnect Gateway User Manual Doc ID HMSI 168 92 Version 4 00
39. ork operator for the SIM card User name Password Required by some mobile network operators Click on Save settings when finished GPS Settings EC250 Settings for communication with an external GPS device These settings should normally be made in Netbiter Argos See the Netbiter Argos Administration Manual tor more information Netbiter EasyConnect Gateway User Manual Doc ID HMSI 168 92 Version 4 00 Local Configuration 40 60 9 3 9 3 1 9 3 2 Netbiter EC310 EC350 Select Login Method Netbiter EC310 and EC350 provide local access via either Ethernet or USB cable USB Connection Connect a USB Micro B cable between the computer and the Netbiter EC310 EC350 After the USB device driver has been installed a virtual network card will automatically be cre ated with an IP address in the range 169 254 200 xxx The local configuration pages of the gateway can now be accessed by entering the IP address 169 254 200 200 in a web browser lol x GE y E Control Panel Network and Internet Network Connections v Search Network Connections E File Edit View Tools Advanced Help Organize v Di 2 A la Local Area Connection 4 sh Enabled S USB Ethernet RNDIS Gadget 2 Fig 64 Network Connections Ethernet Connection Connect an Ethernet cable to the WAN socket on the Netbiter EC310 350 See IP Configuration p 31 on how to find out the IP address of the Netbiter gateway Login Enter the IP
40. port 2 Connect a null modem cable between the serial port on the computer and the D sub connector on the Netbiter gateway 3 Start Netbiter Update The COM port should already be selected Leave the Baudrate setting at Auto len NetbiterUpdate v2 83 C 2005 2009 Intellicom Innovation AB EFE Settings COM Port coma Baudrate auto File Settings Description Version Progress Browse for a NBLI filel Stark programming E nit Fig 76 Netbiter Update 4 Click on Browse and locate the firmware file you downloaded then click Open C250 v1 11 3 b528 nbu NBU File File name EC250 v1 11 3 b528nbu Files of type Netbiter Update nbu ti Cancel I Open as read only Fig 77 File dialog Netbiter EasyConnect Gateway User Manual Doc ID HMSI 168 92 Version 4 00 Netbiter Update EC150 EC250 46 60 5 Power OFF the Netbiter gateway 6 Click on Start programming and wait for the process to complete Fr NetbiterUpdate v2 83 C 2005 2009 Intellicom Innovation AB Fig 78 Start programming 7 Power ON the Netbiter gateway when prompted to do so NetbiterUpdate v2 83 C 2005 2009 Intellicom Innovation AB Fig 79 Power on the Netbiter gateway Netbiter EasyConnect Gateway User Manual Doc ID HMSI 168 92 Version 4 00 Netbiter Update EC150 EC250 47 60 8 Wait for the tool to complete the update NetbiterUpdate v2 83 C 2005 2009 Intel
41. r authentication of the new settings is admin for Netbiter EC150 EC250 and WS series gateways For Netbiter EC300 series gateways the de fault password is the activation code To change the password check the Change password box and enter the current pass word in the Password field and the new password in the New password field then click on Set AN For security reasons the password admin should always be changed Changing the password in IPconfig will not affect the password for logging in to the local configuration pages Click Set to save the new settings and restart the Netbiter gateway Please note it that may take some time before the gateway is online again after a reboot Netbiter EasyConnect Gateway User Manual Doc ID HMSI 168 92 Version 4 00 Activation 33 60 8 Activation 8 1 Adding the Gateway to Netbiter Argos Before a Netbiter EasyConnect gateway can be used it must be registered and activated from a user account in Netbiter Argos For instructions on how to add a Netbiter gateway to Netbiter Argos please refer to the Netbiter Argos Administration Manual which can be downloaded from the Netbiter sup port website www netbiter com support E dr Set Ge tee q ior Gat E aning i rm Ve er 3 Fig 54 Netbiter Argos Netbiter EasyConnect Gateway User Manual Doc ID HMSI 168 92 Version 4 00 Local Configuration 34 60 9 9 1 Local Configuration
42. tbiter EC350 is a standard female SMA screw connector A stub antenna is supplied as standard and optional external an tennas are available from your supplier The Netbiter EC350 also has a built in GPS receiver An external GPS antenna not in cluded should be connected to the female SMA screw connector on the underside of the unit The connector also provides power for active GPS antennas Y Gateway 3G GPRS Fig 21 EC350 antenna connectors SIM Card EC350 The Netbiter SIM cards provided by HMS will load the correct network settings automati cally and do not require configuration SIM cards not issued by HMS will require additional configuration in Netbiter Argos or in the local web pages You must also make sure that the SIM card has a mobile data plan and allows text messaging and that PIN code security has been disabled See the Netbiter Argos Administration Manual and or Modem Settings EC350 p 44 for further information Installing the SIM Card 1 Insert the SIM card carefully into the EC350 as shown in the figure Observe the posi tion of the cut off corner and the contact surfaces When inserting the SIM card make sure it does not accidentally slip behind the SIM card holder 2 Push the SIM card firmly downwards until it clicks into place V Fig 22 Installing the SIM card 1 Antenna is not included when sold in the U S Netbiter EasyConnect Gatevvay User Manual Doc ID HMSI 168 92 V
43. tion and or operation This instruction must be followed to avoid a risk of reduced functionality and or dam age to the equipment or to avoid a network security risk Caution This instruction must be followed to avoid a risk of personal injury Netbiter EasyConnect Gateway User Manual Doc ID HMSI 168 92 Version 4 00 Installation 5 60 2 2 1 Installation Netbiter EC150 EC250 Netbiter EC150 and EC250 are supplied ready for mounting on a DIN rail Mounting L Hook the unit onto the upper lip of the rail 2 Press the unit towards the rail un til it snaps into place my 2 Fig 1 Mounting on DIN rail Removing 1 Insert a flat head screwdriver into the slotted tab on the bottom of the unit and pull the tab gently downwards 2 Pull the bottom end of the unit free of the rail and lift the unit from the rail Nag Fig 2 Removing from DIN rail Netbiter EasyConnect Gateway User Manual Doc ID HMSI 168 92 Version 4 00 Installation 6 60 2 2 Netbiter EC220 EC310 and EC350 Wall Mount USB 12 48 VDC s 2 nebbiter RS485 ec3 50 RS232 Uplink WAN Modem ct 1 2 3 82222555582 RS ee a EE IP Analog In Di Pulse In Relay Power I I gt Gateway e S Power A WAN LAN RS485 RS232 GPS A B COM Rx Tx GND m I 3 Fig 3 EC350 wall mount The Netbiter EC220 EC310 and EC350 can be scre
44. to connect to the RS 232 port 5 female 1 y Fig 51 D sub connector GPS cable pin assignment EC250 RS 232 port GPS device 2 Rx Receive Tx 3 Tx Transmit Rx 5 GND GND Netbiter EC350 The Netbiter EC350 has a built in GPS receiver To use the GPS function connect a suit able GPS antenna not included to the unit Activating the GPS function GPS functionality must be activated in Netbiter Argos before it can be used See the Net biter Argos Administration Manual for more information Netbiter EasyConnect Gateway User Manual Doc ID HMSI 168 92 Version 4 00 Ethernet Network Setup 30 60 7 7 1 Ethernet Network Setup Netbiter EasyConnect gateways should only be installed in networks with firewall protection Contact your network administrator if in doubt Netbiter EasyConnect gateways require outbound outgoing access on the TCP ports listed below to connect to Netbiter Argos Ports used to connect to Netbiter Argos Netbiter model TCP ports EC310 EC350 443 EC150 EC250 5222 443 80 Connection attempts will be made to 3 different servers with a timeout of 30 seconds each This means that it may take up to 4 min 30 sec to establish a connection for EC150 220 250 3 ports x 3 servers x 30 seconds The following ports may also need to be opened in the firewall 502 Default port for Modbus TCP 8080 Extra web server Static Dynamic IP Addressing When using st
45. twork group of op erators A list of these network operators can be found at the Netbiter support website Netbiter EasyConnect Gateway User Manual Doc ID HMSI 168 92 Version 4 00 LED Indicators 23 60 4 4 Netbiter EC310 a a Y O netbiter RS485 ec3 1 O ED RS232 ED Uplink WAN D Gateway ED Power Fig 29 EC350 LED indicators LED Indication Meaning RS485 RS232 Off Port not in use Red steady Port failure contact Netbiter support Green steady Port enabled in Netbiter Argos Uplink WAN Red steady Incorrect IP address settings e DHCP Check for a working DHCP server on the network e Static IP Check that the IP address default gateway and DNS are correctly set Red flashing No connection to Netbiter Argos e Check your network settings e Check that port 443 is open in the firewall Green steady Connected to Netbiter Argos Gateway Off No power or unit is starting up Red steady Hardware failure contact Netbiter support Red flashing Application failure contact Netbiter support Green flashing Firmware update in progress Green steady Unit is operational Power Off No power Green steady Unit has power Fig 30 Ethernet Link LEDs LED Indication Meaning Off No Ethernet traffic Orange flashing Activity on 10 Mbit s network Green flashing Netbiter EasyConnect Gateway User Manual Activity on 100 Mbit s network Doc ID HMSI 168 92 Vers
46. w mounted directly to a flat surface us ing the screw holes in the metal housing DIN Rail Mount Fig 4 DIN rail mounting kit The Netbiter EC220 EC310 and EC350 can also be mounted on a DIN rail using an option al rail mounting kit Netbiter EasyConnect Gateway User Manual Doc ID HMSI 168 92 Version 4 00 Connections 7 60 3 Connections Netbiter EasyConnect gateways can be connected to Modbus devices via different interfa ces and physical connections Which interface s to use is configured in Netbiter Argos 3 1 Netbiter EC150 3 1 1 Terminal block 12 pin Fig 5 Terminal block Terminal block connections Pin Label Function Note 24 Vin Power 9 24 VDC VAC EC150 can optionally be powered by 9 24 VAC 23 Vin PE ground 22 DI DI2 Low 0 2 VDC High 10 24 VDC 21 DI DI1 Low 0 2 VDC High 10 24 VDC 20 DI COM Digital input common 17 RS 232 RX RS 232 Receive 16 RS 232 TX RS 232 Transmit 15 COM Serial interface common Shared between RS 232 and RS485 14 RS 485 A RS 485 Line A 13 RS 485 B RS 485 Line B Netbiter EasyConnect Gateway User Manual Doc ID HMSI 168 92 Version 4 00 Connections 8 60 3 1 2 D sub Connector The 9 pin male D sub connector provides an RS 232 interface for Modbus RTU D sub connector pin layout U 5 Function CD Carrier Detect Rx Receive Tx Transmit 1 male 5 DTR Data Terminal Ready
47. work Click on Save settings when finished 9 3 6 Firmware Update Firmware updates can also be made through Netbiter Argos See the Netbiter Argos Ad ministration Manual Status Firmware update Network settings Modem settings Current version 142 Update progress Not running Mia Firmware update file Browse No file selected About Start upgrade Don t save settings Fig 74 Firmware update The Netbiter gateway must be connected to the Internet to ensure that the internal clock has synchronized the time and date before updating the firmware 1 Download the latest firmware from www netbiter com support 2 Click on Browse and select the firmware file you downloaded 3 Click on Start upgrade to start the update AN Do not close the web page while the update is in progress Netbiter EasyConnect Gateway User Manual Doc ID HMSI 168 92 Version 4 00 Local Configuration 44 60 9 3 7 Modem Settings EC350 Modem settings and information about the mobile connection These settings can also be made in Netbiter Argos A SIM card with SMS capability is re quired See the Netbiter Argos Administration Manual Status Modem settings Network settings Modem settings Use modem as primary connection to Argos Firmware update Logs APN apn internet com About User Password Signal quality III 23131 3G Modem connection Radio access technology UTRAN Save settings Do