DHX Disposable Heat Exchanger User Manual
Contents
1. DHX DISPOSABLE HEAT EXCHANGER DHX Disposable Heat Exchanger User Manual cee DISPOSABLE HEAT EXCHANGER Thermo Fisher Scientific 163 Research Lane Millersburg PA 17061 1 717 692 2104 1 800 724 4158 wwwaasisus com ASI A Part of Thermo Fisher Scientific is an FDA Registered ISO 13485 2003 Certified Manufacturer MK 00382 04 16 15 A part of Thermo Fisher Scientific DHX DISPOSABLE HEAT EXCHANGER USER MANUAL SASI A part of Thermo Fisher Scientific TABLE OF CONTENTS 1 General Description 2 Specifications I 2 1 Dimensions and Weight 1 2 2 DHX Plate System il 2 3 Single Use Bag Assembly 1 3 Main Components 2 4 Safety Requirements 3 Dy Installation 3 5 1 Incoming Inspection 3 5 2 DHX Plate Installation 3 5 3 DHX Plate System Optional Configurations 5 6 Operation 6 1 Single Use Bag Assembly Loading 6 2 Operation 9 6 3 Single Use Bag Assembly Breakdown 10 7 Maintenance 10 7 1 During Operation 10 7 2 Annually 10 8 Troubleshooting 12 9 Warranty Information 12 10 Recommended Parts 13 11 Contact Information 14 DHX DISPOSABLE HEAT EXCHANGER USER MANUAL SASI A part of Thermo Fisher Scientific 1 GENERAL INFORMATION The DHX Single Use Heat Exchanger is a modular system where stainless steel dimpled plates are used in conjunction with a single use bag assembly to provide heat transfer The DHX assembly consists of a series of removable stainless steel plates that are dimpled and seam welded int
2. 52411 3 212 The DHX inlet and outlet connections are 2 compression fittings as standard It is highly recommended that a strainer be used upstream of the DHX plate system if the heat transfer fluid may contain debris Any debris that collects within the DHX will restrict flow and affect performance Connect the heat transfer fluid inlet and outlet connections as shown below E ee th WAAN AT Yi 7 oo ak e es Ve 1 Ss EAN y UESN A w X A s w s k uN i n N y b T a m gt 4 s o a 7 i d y w IAK E Wk kel p i HTF INLET HTF OUTLET The DHX plate system operates independently of the single use bag assembly The installation of a single use bag assembly is not required during the initial priming of the plate system Ensure all of the hoses are connected securely to each plate and the high point vent valves are closed Ensure the plate system is closed using the locking and fanning levers Ensure the six 6 DHX plate system hinges are secure Ensure the bolts are sitting in the recessed section of the plate tab and the six 6 wing nuts are firmly hand tightened Open the heat transfer circuit to the DHX It is normal to hear some knocking as the plate system initially pushes the air through the plates Bleed off the air in each plate using the high point bleed valves and a small container to collect any released heat transfer fluid The bleeding step
3. Move Fanning Lever towards the Locking Lever DHX is in the Open Position 6 www asisus com DHX DISPOSABLE HEAT EXCHANGER USER MANUAL SASL 6 1 4 6 1 5 6 1 6 A part of Thermo Fisher Scientific Note there are tabs to secure each bag to the corresponding plate on the top and bottom of the single use bag For ease of installation all tabs should be separated prior placing the bags between the plates Insert each bag used in the 1 4 single use bag assembly within each corresponding plate Ensure the tubing is cascading from one bag to the next Reference section 5 3 to view the two different configuration options if using less than all five 5 plates Attach the bottom tabs of each bag first NOTE Pressing the stud through the slit at the bottom is made easier by alternately tugging up at the top of the bag with one hand and pushing down at the tab area with the other Once the bags are secure at the bottom engage each set of top tabs Remove and discard any loose pieces from the tabs after they are in place The process flow must always be set up so the process fluid fills from the bottom of the bag to the top of the bag to displace any air throughout the single use bag assembly For DHX bag assemblies with drain ports DX00010 I DX00013 I ensure that the drain port is connected to the proper drain connection in the process Close the pinch clamps on each drain line before starting the process fluid flow DHX Disposa
4. placed on top of the heat transfer hoses before closing the DHX section 6 1 7 and re open the DHX Follow the instructions in section 6 1 to properly align the flow path tubing 9 WARRANTY INFORMATION The DHX from ASI is covered under a 1 Year Limited Warranty ASI will not be liable under any warranty expressed or implied in any amount greater than the price of the product sold 12 www asisus com DHX DISPOSABLE HEAT EXCHANGER USER MANUAL 10 RECOMMENDED PARTS To ensure there is the minimum amount of machine downtime ASI recommends that the following items be maintained minimum quantity in the manufacturing facility spare parts inventory Contact ASI for spare parts Other parts may be replaced if needed A part of Thermo Fisher Scientific 10 1 PARTS LIST Position Description Recommended Spares Model DHX 1000 Model DHX 1001 N A Disposable Heat Exchanger Assembly 30 DHX 1000 30 DHX 1013 A DHX Cart Base 30 DHX 1001 30 DHX 1014 N A B HTF Inlet Insulated Plate 30 DHX 1002 30 DHX 1015 N A C HTF Outlet Insulated Plate 30 DHX 1003 30 DHX 1016 N A D Inside Plate 30 DHX 1004 30 DHX 1017 N A E Inside Mid A Plate 30 DHX 1022 30 DHX 1018 N A F Inside Mid B Plate 30 DHX 1023 30 DHX 1019 N A G Safety Lever 30 DHX 1005 30 DHX 1020 N A H Locking Caster 30 DHX 1006 30 DHX 1006 N A I High Point Bleed Valve 30 DHX 1007 30 DHX 1007 2 J DHX Plate Hose Ass y
5. 30 DHX 1008 30 DHX 1008 2 K DHX Support Bolt 30 DHX 1009 30 DHX 1009 2 L DHX Support Wingnut 30 DHX 1010 30 DHX 1010 2 M Hinge Pin 30 DHX 1011 30 DHX 1011 N A N A Flexible Insulation Insert 30 DHX 1012 30 DHX 1012 1 If applicable DHX Disposable Heat Exchanger 13 DHX DISPOSABLE HEAT EXCHANGER USER MANUAL SASI A part of Thermo Fisher Scientific 11 CONTACT INFORMATION CUSTOMER CARE Your ASI equipment has been designed to provide you with years of reliable and dependable performance To ensure that you maintain maximum performance over the years we offer a complete package of customer services including Original Quality Replacement Parts Factory Repair Service Field Service Process Application Assistance Preventive Maintenance Programs Training Programs ASI maintains complete manufacturing records of all ASI equipment and will repair your unit to meet the original specifications If required units can be updated to the very latest technologies in materials and design We wish you much success with your new ASI equipment and thank you for your confidence in our equipment The entire ASI Corporate Team is here for one purpose and that is to make sure you obtain maximum results from our equipment If you need assistance please call immediately ASI Customer Care Department 163 Research Lane Millersburg PA 17061 1 717 692 2104 customerservice2 asisus com 14 www asisus com
6. HX Plates DHX Disposable Heat Exchanger 5 A part of Thermo Fisher Scientific DHX DISPOSABLE HEAT EXCHANGER USER MANUAL SASI 6 OPERATION 6 1 SINGLE USE BAG ASSEMBLY LOADING NOTE Ensure all four 4 casters are in the locked position down before loading the bag assembly into the DHX 6 1 1 Isolate the heat transfer fluid circuit to stop the heat transfer circuit from flowing through the DHX plate system It is acceptable to have the plates pressurized with heat transfer fluid during the bag loading 6 1 2 Remove the wing nuts and bolts from the six 6 DHX plate system hinges in the order shown in the diagram below NOTE It is a good practice to have a free hand under the wing nut during its removal to prevent it from dropping to the floor 6 1 3 Once the bolts are removed the DHX will open slightly and relax against the locking mechanism Use the safety levers to fan out the plates this can be done by pulling the locking lever located towards the bottom closest to the heat transfer fluid ports slightly to release the locking mechanism As shown in step 1 Then using the upper fanning lever move it towards the locking lever with control to fan out the DHX plates As shown in step 2 Remove the insulation foam spacers if applicable The DHX is now in the open position and the single use bag assembly can be placed Fanning Lever Fanning Lever Locking bever ir BY x Step 1 Pull on the Locking Lever Step 2
7. Hinges 6 total Fixed Insulation on Each End Plate Single Use Tubing Connects Bag Assemblies High Point Vent Valves Wing Nut 6 total Flexible Hoses Connect Fanning Lever Plate System Locking Lever Cart Base Clean Room Grade Casters 4 SAFETY REQUIREMENTS 4 1 4 2 4 3 44 4 5 4 6 4 7 2 The appropriate safety devices must be integrated as outlined in the installation section Pages 3 5 in order to prevent the over pressurization of the DHX plate system National as well as local codes and standards must be followed for pressure vessels as it applies to the DHX plate system Instrumentation and automated interlocks are recommended to prevent over pressurization and or rupture of the single use bag assembly as outlined in the installation section Pages 3 5 The six 6 DHX plate system hinges with wing nuts must always be firmly secured during operation Failure to install and tighten all of the six 6 hinges properly poses an operator safety risk and may cause mechanical damage The DHX safety lever must always be used when opening and closing the plate system to avoid pinch point hazards Failure to follow ASI s installation and operation instructions may affect the DHX performance and overall functionality It is the user s responsibility to maintain the DHX for optimal performance wWww asisus com DHX DISPOSABLE HEAT EXCHANGER USER MANUAL SASL 5 A part of Thermo Fisher Scientific
8. INSTALLATION Perform the following steps to initially install the DHX one e INCOMING INSPECTION 5 1 1 Carefully uncrate the DHX 5 1 2 Thoroughly review the product for damage 5 1 3 Check the product and components against the parts list Section 10 1 5 1 4 If the product is damaged or if the shipment is not complete please contact ASI Customer Care immediately ASI Customer Care 163 Research Lane Millersburg PA 17061 717 692 2104 or 800 724 4158 DHX SYSTEM INSTALLATION 5 2 1 Unlock all four 4 casters and transport the DHX to the desired location 5 2 2 Ensure the DHX is on a level surface and lock the casters in place 5 2 3 The recommended installation setup for the DHX system is shown in diagram below See 5 3 3 2 Note It is recommended that any unused plates be capped or sealed appropriately T9 ae TE PROCESS OUTLET a pola ae RIAIR i en men D H E i i i m a mi PROCESS INLET TE PI XOH HTF SUPPLY PUMP OR TCU HTF OUTLET HX High pressure interlock recommended to shut down pumps or flow source Temperature control loop recommended for heating and high temperature applications May not be required for cooling applications DHX Disposable Heat Exchanger 3 DHX DISPOSABLE HEAT EXCHANGER USER MANUAL SASI A part of Thermo Fisher Scientific 5 INSTALLATION CONTINUED 4 5 2 4 2 2 03 5 2 6 22 1 5 2 8 TAJ 5 2 10 Note
9. Tubing Placed Correctly 8 www asisus com DHX DISPOSABLE HEAT EXCHANGER USER MANUAL SASL A part of Thermo Fisher Scientific 6 OPERATION CONTINUED 6 1 14 Re install the hinge bolts one at a time in the order shown in the diagram below Place all of the bolts before fully tightening them and ensure that each bolt is recessed in the plate tab appropriately It is good practice to check the tightness of the side bolts after tightening the top bolts and vice a versa NOTE It may be necessary to pull on the fanning lever while installing the hinge bolts to assist the process 6 2 OPERATION 6 2 1 Once the fluid connections are made start the processing by resuming the heat transfer fluid circuit The flow of the heat transfer fluid can be initiated up to 15 LPM The bleed valves at the top of each plate can be used to vent any trapped air A piece of tubing should be used to direct any fluid that may exit the valves to a waste receptacle 6 2 2 Start the process flow slowly starting at 3 LPM or less The bags fill from the bottom to top displacing the air as the process fluid cascades through the assembly 6 2 3 Carefully monitor the bag assembly during the priming step to ensure there are no leaks the tubing is not pinched and all air is being displaced accordingly 6 2 4 Once the bag assembly is primed the desired flow rate may be set and the process can run continuously Anytime the flow is stopped while in operation
10. ble Heat Exchanger 7 DHX DISPOSABLE HEAT EXCHANGER USER MANUAL SASI A part of Thermo Fisher Scientific 6 OPERATION CONTINUED 6 1 7 The process must be set up for counter current flow where the process fluid enters from the opposite side of the heat transfer fluid in order to provide the most efficient heat transfer method The process fluid should cascade through each bag in the series in the opposite direction of the heat transfer fluid path 6 1 8 There must always be positive pressure on the process inlet side of the DHX for proper functionality Process Fluid Heating Cooling Fluid 6 1 9 Connect the inlet and outlet of the single use bag assembly to the upstream and downstream process connections with the DAC s tube welds or connections specified for the user s custom bag assembly 6 1 10 If the optional single use bag assembly with low point drains are used the low point drain connections are manifolded together 6 1 11 The single use flow path tubing left in its natural state could be trapped between the braided heat transfer hoses when the DHX unit is being closed To prevent this rest the single use flow path tubing across the top of the heat transfer hose assemblies Ensure that both hands and the flow path tubing are clear from the plate system while closing the DHX unit using the fanning lever and engaging the lock and reinstalling the hinge bolts Flow Path Tubing in Natural State Incorrect Flow Path
11. ernally to form a serpentine pattern The plates are connected with a series of hoses The serpentine pattern on the stainless steel plate system matches the serpentine pattern on the single use bag assembly The single use bags are manifolded together with disposable tubing Heat transfer fluid is intended to flow through the plate system counter current to the process fluid flowing within the single use bag assembly The temperature differential of the heat transfer fluid and the counter current flow patterns provide efficient heat transfer to the process fluid within the single use bag assembly 2 SPECIFICATIONS 2 1 DIMENSIONS AND WEIGHT Height 27 68 6 cm Width 20 50 8 cm Depth 29 73 7 cm Dry Weight 331 Ibs 150 Kg Full Weight with 4 Bag Assembly 419 Ibs 190 Kg 2 2 DHX PLATE SYSTEM Number of Plates 5 Effective Heat Transfer Area Up to 27 sq ft Material of Construction 316L SS Pressure Temperature Rating FV 140 PSIG 150 F Standard Code Stamp ASME U 1 Standard Each plate individually stamped 2 3 SINGLE USE BAG ASSEMBLY Number of Bags Up to 4 Bag Material of Construction Low Density Polyethylene Pressure Temperature Rating 20 psig 122 F 50 C DHX Disposable Heat Exchanger 1 DHX DISPOSABLE HEAT EXCHANGER USER MANUAL SASI A part of Thermo Fisher Scientific 3 MAIN COMPONENTS Tabs Hold Bag in Place Plate System
12. et To use the process inlet the process outlet and low point drain manifold outlet tubing should be closed using a clamp Open the pinch clamps on each individual drain line before starting the process fluid flow The process fluid can be recovered by reversing the pump and routing the process fluid to an appropriate collection container Alternately to use the low point drain manifold outlet the process inlet and outlet tubing of the bag assembly should be closed using a clamp and the low point drain manifold outlet tubing can be routed to a pump so the process fluid may be recovered Open the clamps on each individual drain line before starting the process fluid flow Discard the assembly in the appropriate waste stream as dictated by the end user s requirements 7 MAINTENANCE Following is a basic list of maintenance items to be performed at varying intervals rae ROUTINE MAINTENANCE 7 1 1 LLA Routinely inspect the plate system for rouge pitting or signs of corrosion De rouge and or passivate the plate system accordingly If applicable inspect and clean the strainer upstream of the plate system routinely to ensure the target heat transfer fluid flow rate is maintained 7 2 PREVENTATIVE MAINTENANCE 12d 7 2 2 12 3 Remove the hoses and inspect the plate inlet outlet connections for signs of debris If signs of debris are evident or if it is suspected that debris has settled in the bottom of the plates clean and fl
13. it is recommended to slowly ramp up the pump when the flow is resumed This recommendation is especially the case for high flow rate applications in order to prevent pressure surges in the single use bag assembly DHX Disposable Heat Exchanger 9 DHX DISPOSABLE HEAT EXCHANGER USER MANUAL SASI A part of Thermo Fisher Scientific 6 3 SINGLE USE BAG ASSEMBLY BREAKDOWN 6 3 1 6 3 2 6 3 3 6 3 4 6 3 5 Once the process operation is complete the single use bag assembly should be depressurized and drained to the extent possible prior to removal from the DHX plate system After the bags have been partially drained and the bags are no longer pressurized remove the wing nuts and bolts from each of the six 6 DHX plate system hinges Open the DHX plate system using the safety levers Section 6 1 3 Release the bottom and top tabs on all the bags and remove the single use bag assembly If gross recovery of the process fluid is desired start with the bag at the process inlet remove the bag tabs from the corresponding connection points on the plate and gently lift and tilt the bag toward the drain lines Once the first bag is nearly drained repeat the process with the consecutive bags until the last bag in the assembly has been drained If the single use bag assembly with low point drains was used any remaining process fluid may be recovered through the process inlet by reversing the pump or through the low point drain manifold outl
14. ld enter the system from the opposite side as the heat transfer fluid The bags should flow from bottom to top where the single use tubing at the top of the bag should connect to the bottom of the next bag in series Lack of positive pressure on 1 Ensure there is sufficient pressure so the single use bags fit bag assembly tightly within each plate 2 Ensure there is a source to apply positive pressure upstream of the DHX system See Figure on page 3 Heat transfer fluid flow rate is 1 Verify heat transfer fluid flow rate too low 2 Ensure the hoses plate system connections and plate system is not clogged with debris If applicable ensure the strainer is clean 3 Ensure the DHX plate system hoses are not kinked Process fluid flow rate is not at 1 Verify the process fluid flow rate set point 2 Ensure the single use bag assembly hoses are not kinked or pinched between the DHX plate system hoses Single use bag assembly have 1 Inspect the single use bags to ensure the bottom and top tabs improper fit up are secure 2 Inspect the fit up of each single use bag to ensure the serpentine pattern matches the corresponding DHX DHX plate system contains 1 Ensure DHX system is on a relatively flat surface and bleed valves pockets of air are at the high point 2 Bleed any residual air from the DHX Plate system using the high point bleed valves Lack of sufficient insulation 1 Ifall plates are not in use reference section 5 3 en
15. s should be repeated until all the air is expelled from the DHX plate system Once the DHX plate system is bled it is ready for operation www asisus com DHX DISPOSABLE HEAT EXCHANGER USER MANUAL SASL A part of Thermo Fisher Scientific 5 INSTALLATION CONTINUED Do DHX PLATE SYSTEM OPTIONAL CONFIGURATIONS 5 3 1 The DHX system is a modular and changeable system in which 1 3 bag assembly can be used All five 5 plates are not required at one time If either a 1 3 bag assembly is used there are two options in setting up the DHX plate system Insulation Foam Spacers 5 3 2 Option 1 Insulation foam between the unused plates 5 3 2 1 The heat transfer fluid may run through all five plates with 1 3 bag assembly Flexible insulation foam spacers are provided by ASI and inserted between every unused plate after the bags have been installed These insulation foam spacers must be used to prevent damage or warping to the plates 5 3 3 Option 2 Bypassing the unused DHX Plates 5 3 3 1 The unused plates in the DHX system may be disconnected per the example to the right Insulation foam spacers must be inserted between every unused plate to prevent damage or warping Insulation Foam Spacers 5 3 3 2 The installation and bleeding instructions in section 5 2 must be followed accordingly for the plates in use if Option 2 is chosen Any unused plates should be capped or sealed appropriately Disconnected D
16. sure flexible insulation is installed on the outer side of the last plate in series DHX palte system has exceeded 1 Verify the process and heat transfer fluid flow rates align with the the heat transfer capacity DHX sizing calculations Contact ASI for support as necessary DHX Disposable Heat Exchanger 11 DHX DISPOSABLE HEAT EXCHANGER USER MANUAL 8 TROUBLESHOOTING CONTINUED A part of Thermo Fisher Scientific Problem DHX plate system and or plate system hinges are becoming warped as single use assemblies are filled or during normal operation Single Use Flow paths are trapped between the heat transfer hoses Probable Causes DHX plate system supports are installed incorrectly Solutions 1 Ensure the all six 6 DHX support bolts are sitting securely in the recessed grooves Single use bag assembly has 1 Ensure the pressure on the single use bag assembly does not exceeded its pressure rating exceed 20 psig at 50 C Note High pressure interlocks are highly recommended per Figure on page 3 2 Ensure there are no pressure surges during initiation of process flow DHX plate system has 1 Ensure the heat transfer fluid pressure does not exceed the exceeded its pressure rating pressure rating of the DHX plate system Note A pressure safety valve ts highly recommended per Figure on page 3 The flow paths were not 1 Before Fluid is introduced remove the bolts as instructed in
17. ush the DHX plate system accordingly Inspect the DHX plate system hoses for any signs of kinking or excessive wear Replace hoses as necessary Inspect the bleed valves to ensure proper performance Replace bleed valves as necessary Note It is recommended that the preventative maintenance procedures are completed on an annual basis for systems in regular use Hoses are recommended to be replaced at least every two years Preventative maintenance intervals may be revised at the discretion of the end user based on system use and service 10 www asisus com DHX DISPOSABLE HEAT EXCHANGER USER MANUAL 8 TROUBLESHOOTING A part of Thermo Fisher Scientific The following table lists possible situations that may occur during operation of the DHX and courses of action to pursue to correct them Problem Probable Causes Solutions Process fluid is not reaching the desired temperature at the DHX outlet DHX system is set up incorrectly 1 Ensure the system is set up per Figures on pages 2 and 3 2 Ensure the heat transfer inlet connection is at the top of each plate The hose at the heat transfer outlet connection at the bottom of each plate and should be connected with a hose to the inlet connection at the top of the next plate in series 3 Ensure the single use bag assembly is set up to flow in the opposite direction counter currently to the DHX plate system The process fluid shou