1. 15 LIMITED WARRANTY 16 COMPRESOR DE NEBULIZADOR MANUAL USUARIO EN ESPA OL 19 GF Health Products Inc is not responsible for typographical errors AII illustrations specifications packaging and warranties contained in this literature are based on the latest product information available at the time of printing The most current product information including the most current version of this manual can be found online at www grahamfield com Graham Field John Bunn and Neb u Lite are registered trademarks of GF Health Products Inc 2007 GF Health Products Inc JB0112 110 INS LAB RevC14 2 IMPORTANT SAFEGUARDS READ ALL INSTRUCTIONS BEFORE USING When using electrical products especially when children are present always follow basic safety precautions including the following A A DANGER Indicates a potential hazard situation or unsafe practice that if not avoided will result in death or serious personal injury WARNING Indicates a potential hazard situation or unsafe practice that if not avoided could result in death or serious personal injury CAUTION Indicates a potential hazard or unsafe practice that if not avoided could result in minor or moderate personal injury NOTICE Indicates a potential hazard or unsafe practice that if not avoided could result in product or property damage Info Provides application recommendations or other useful
2. n importante y precauciones de seguridad para el John Bunn Neb u Lite LX2 Compresor de Nebulizador Antes de usar su Compresor de Nebulizador favor de leer y entender el manual de usuario Tome nota especial en todas las precauciones marcadas PELIGRO y ADVERTENCIA Guarde este manual de usuario para referencia en el futuro Uso del Compresor de Nebulizador El Neb u Lite LX2 Compresor de Nebulizador es dise ado para proveer una fuente de aire comprimido para la terapia de aerosol Se usa en conjunto con un nebulizador de chorro neum tico para producir aerosoles de medicamento para inhalaci n por pacientes adultos y pedi tricos con s ntomas respiratorios Indicaciones para terapia incluye asma bronquitis cr nica infecci n de la zona superior respiratorio enfermedad pulmonar obstructiva cr nica y otros desordenes que va de acuerdo con la receta de su m dico No debe usar este producto por cualquier otro prop sito que lo descrito arriba Este aparato puede ser usado con pacientes adultos y pedi tricos con la receta de su m dico Simbolos o BEL MN o Atenci n lea las instrucciones Clase Il no aplicable para UL1431 riesgo de descarga el ctrica por equipo de tipo BF no aplicable por UL1431 Disposici n de Equipo El ctrico y Electr nico WEEE Este producto no debe ser tratado como residuos dom sticos pero sometidos a un sitio de colecci n para reciclaje de equipo BF Este pr
3. siga ese procedimiento Z ADVERTENCIA Para prevenir riesgo de infecci n causado por medicamento contaminado la limpieza del nebulizador se recomienda despu s de cada tratamiento 1 Despu s de cado uso desensamble la taza del nebulizador el adaptador T y la boquilla completamente Lave todas las piezas en agua tibia con jab n y enjuague bien 2 A diario despu s del paso anterior remoje los componentes del nebulizador en una soluci n consistiendo de una parte agua y una parte vinagre por 30 minutos seguido por un enjuague con agua tibia JB0112 110 INS LAB RevC14 12 Instrucciones para el cambio del filtro de aire A AVISO Cambie el filtro cada 30 d as o cuando el filtro tenga un color gris Info Filtros adicionales pueden ser comprados en www grahamfield com o de su distribuidor autorizado de Graham Field 1 Remueva la tapa del filtro de aire localizado al lado del interruptor ON OFF 2 Remueva el filtro sucio con un objeto punzante 3 Reemplace el filtro nuevo 4 Reemplace la tapa del filtro A AVISO No utilice algod n o cualquier material como filtro A AVISO No lave o limpie el filtro A AVISO No reutilice el filtro No opere sin filtro El compresor puede ser da ado por este uso Z ADVERTENCIA El kit del nebulizador desechable es para uso solamente de una persona Almacenaje Mantenga el aparato y los accesorios secos Evite sol directamente JB0112 110 INS LAB RevC14 13 DETEC
4. Uso de un nebulizador armado incorrectamente puede disminuir o impedir reparto adecuado de medicamento y la efectividad del tratamiento JB0112 110 INS LAB RevC14 9 OPERACION A AVISO El Neb u Lite LX2 Compresor de Nebulizador esta disenado para uso solamente por periodos No debe operarlo continuamente por mas de 30 minutos en un uso sin apagarlo y dejar que se enfrie por lo menos 30 minutos 1 Asegurase que el interruptor el ctrico est en la posici n OFF 2 Conecte el cord n el ctrico en la toma el ctrica apropiada 3 Encienda el compresor posicionando el interruptor a ON 4 Acomode la boquilla del nebulizador entre los dientes y cierre la boca o instale la m scara opcional en la cara 5 Cuando el aerosol empiece a fluir necesita inhalar profundamente y despacio a trav s de la boquilla o la m scara Z ADVERTENCIA Nunca debe usar el nebulizador con un inyector tapado Si el inyector est tapado la nube de aerosol ser reducido cambiado o parado que puede diminuir o eliminar la efectividad del tratamiento Si se tapa reemplace el nebulizador Info Si el tratamiento necesita ser interruptado posicione el interruptor a la posici n OFF 6 Cuando el tratamiento haya terminado apague el compresor posicionando el interruptor en la posici n OFF 7 Desenchufe el aparato de la toma el ctrica 8 Desconecte el nebulizador del mango 9 Limpie el nebulizador siguiendo las instrucciones escrito
5. WARNING Ensure that the nebulizer compressor is unplugged during setup 1 Before each use inspect the compressor and nebulizer cup assembly for damage or wear replace as needed 2 Place the compressor on a table or other flat stable surface not on the floor in an area that is clean and dust free Be sure you can easily reach the controls when seated 3 Open the nebulizer medication cup Twist the cap counter clockwise until it stops then lift cap off 4 Pour the prescribed medication into the nebulizer medication cup Do not fill with more than 5 ml per treatment 5 Install on cup Turn clockwise to t tighten install cap on cup 6 If using the mouthpiece for treatment proceed to step 7 If using an optional mask install the bottom part of the mask directly onto the top of the nebulizer medication cup cap as shown at right Proceed to step 9 install mask on cap 7 Insert mouthpiece into large end of T adapter T adapter assemble mouthpiece and T adapter JB0112 110 INS LAB RevC14 Info The reservoir tube shown in the illustration earlier in this manual acts as a holding tank for the mist reducing the amount lost during treatment Its use is optional If you wish to use the reservoir tube install it now on the small end of the T adapter 8 Install T adapter onto top of id nebulizer medication cup cap i T adapter 9 Connect the tubing to the adapter Baap on the bottom of the
6. and cleaning and 8 Representations and warranties made by any person or entity other than GF JB0112 110 INS LAB RevC14 16 ENTIRE WARRANTY EXCLUSIVE REMEDY AND CONSEQUENTIAL DAMAGES DISCLAIMER THIS WARRANTY IS GF S ONLY WARRANTY AND IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED GF MAKES NO IMPLIED WARRANTIES OF ANY KIND INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE IF ANY MODEL OR SAMPLE WAS SHOWN TO THE CUSTOMER SUCH MODEL OR SAMPLE WAS USED MERELY TO ILLUSTRATE THE GENERAL TYPE AND QUALITY OF THE PRODUCT AND NOT TO REPRESENT THAT THE PRODUCT WOULD NECESSARILY CONFORM TO THE MODEL OR SAMPLE IN ALL RESPECTS THIS WARRANTY IS LIMITED TO THE REPAIR OR REPLACEMENT OF THE DEFECTIVE PARTS GF SHALL NOT BE LIABLE FOR AND HEREBY DISCLAIMS ANY DIRECT SPECIAL INDIRECT INCIDENTAL EXEMPLARY OR CONSEQUENTIAL DAMAGES INCLUDING BUT NOT LIMITED TO DAMAGES FOR LOSS OF PROFITS OR INCOME LOSS OF USE DOWNTIME COVER OR EMPLOYEE OR INDEPENDENT CONTRACTOR WAGES PAYMENTS AND BENEFITS The warranties contained herein contain all the representations and warranties with respect to the subject matter of this document and supersede all prior negotiations agreements and understandings with respect thereto The recipient of this document hereby acknowledges and represents that it has not relied on any representation assertion guarantee warranty collateral contract or other a
7. 0 minutes between uses The mouthpiece and optional mask are for use by one person only in order to avoid infection do not share them Notice for California Customers California Proposition 65 WARNING This product contains a chemical known to the State of California to cause cancer and reproductive or developmental harm SAVE THESE INSTRUCTIONS JB0112 110 INS LAB RevC14 INTRODUCTION This user manual contains important information and safety precautions for the John Bunn Neb u Lite LX2 Nebulizer Compressor Before using your Nebulizer Compressor please read and understand this entire user manual Take special note of all safety precautions marked DANGER and WARNING Save this user manual for future reference Intended Use The Neb u Lite LX2 Compressor Nebulizer System is designed to provide a source of compressed air for aerosol therapy It is used in conjunction with a jet pneumatic nebulizer to produce medicated aerosols for inhalation by pediatric and adult patients with respiratory symptoms Indications for therapy include asthma chronic bronchitis infection of the upper respiratory tract chronic obstructive pulmonary disease and other respiratory disorders in accordance with a physician s prescription Do not use this product for any other purpose than the preceding This device can be used with adults or pediatric patients under physician s prescription Symbols Key Alternating current Enc
8. 50V MFG Negro 6 ft 182 9 cm 10 De tipo de 2 Aspa Temperatura Operaci n 50 F a 104 F 10 C a 40 C Almacenaje 5 F a 122 F 15 C a 50 C Transporte 50 F a 104 F 15 C a 70 C Humedad Operaci n 10 a 90 RH no condesado Almacenaje 10 a 90 RH no condesado Transporte 10 a 90 RH no condesado JB0112 110 INS LAB RevC14 15 GARANTIA AMBITO DE GARANT A GF Health Products Inc GF garant a al comprador original o arrendatario cual quiera es el Cliente solamente que va reemplazar o reparar componentes a la decisi n solo de GF cuales son defectos en material o calidad utilizado normalmente y con servicio La garant a es para partes solamente y no incluye fuerza laboral o el costo de transporte Esta garant a limitada no es transferible Todas garant as son condicionales por el uso apropiado del producto estrictamente en acuerdo con las instrucciones aplicables de GF incluyendo uso apropiado y mantenimiento Producto pr vido a usuarios como r ntales deben ser serviciados por el proveedor y inspeccionado antes de entrega Cada usuario debe ser preparado en la operaci n y seguridad de este producto antes de uso Dentro las reglas normales en este documento el John Bunn JB0112 110 Compresor Nebulizador y sus componentes a estar libre de defectos de materiales o mano de obra seg n listado debajo Compresor cinco a os Accesorios seis meses El per odo de garant a se comienza en l
9. IMPORTANTES DE SEGURIDAD esee nennen 3 INTRODUCCION E I 6 USO DEL COMPRESOR DE NEBULIZADOR sscsssssseesesssseseeseensseeeennensseeeeennenes 6 SIMBOLOS 6 DESCRIPCION DEL PRODUCTO nnentenententenennannennn tente ntetnn tente ntntenns 7 CARACTER STICAS Y COMPONENTES sees esee nennen nnn nnne 7 ENSAMBLAJE 8 OPERACI N ici ia SEGURIDAD EN CASO DE MANTENIMIENTO vasin LIMPIEZA DE LA CARCASA DEL COMPRESOR a LIMPIEZA DE LA TAZA DEL 2 INSTRUCCIONES PARA EL CAMBIO DEL FILTRO DE AIRE 13 ALMACENAJE eese nnn rnnt nnns tn snnt 13 DETECTANDO PROBLEMAS 14 ESPECIFICACIONES ccccccscsssseessesseessesseesesseeseesseeseesusseesaesseessesseesaessenseesseseaessensensanees 15 sentenced da 16 GF Health Products Inc no es responsable de errores tipogr ficos Para obtener la informaci n m s actualizada y vigente relativa a los envases garant as productos y especificaciones incluyendo la versi n m s actualizada de estas instrucciones por favor visite nuestro sitio web en www grahamfield com Graham Field John Bunn y Neb u Lite son marcas registradas de GF Health P
10. JOHN BUNN Neb u Lite LX2 E305033 Nebulizer Compressor Item JB0112 110 User Manual Read this manual before operating the nebulizer Save this manual for future reference A Federal Law USA restricts this device to sale by or on the order of a physician This device should not be used unless the operator has been instructed by a qualified healthcare professional JB0112 110 INS LAB RevC 14 This product has been tested and successfully approved with the following standards UL1431 EN 60601 1 EN 60601 1 2 C c 0197 IMPORTANT SAFEGUARDS oro cesses tes ec iro iet se cerei ro soc eere oe tes eterne 3 INTRODUCTION MS INTENDED USE eae SYMBOLS KEY AAA PRODUCT DESCRIPTION i cccccccececscscceesseccssceccesneteetececcteresuesocecetecetencedecrensereues spen nth nsn 7 FEATURES AND COMPONENTS sees nennen nnne nnns ntn nnn nn ann 7 OPERATION 10 SAFETY 11 MAINTENANCE coi 12 CLEANING THE COMPRESSOR S OUTER CASE 12 CLEANING THE NEBULIZER nnne nennen nnn 12 REPLACING THE eene nennen 13 STORAGE m 13 TROUBLESHOOTING o 14 SPECIFICATIONS ssassn leesne
11. S PAGOS O BENEFICIOS Esta garant a te da derechos legales espec ficos Podr s tener derechos adicionales que var an estado por estado JB0112 110 INS LAB RevC14 17 Fabricado para GF Health Products Inc 2935 Northeast Parkway Atlanta Georgia 30360 USA Telephone 770 368 4700 Fax 770 368 2386 GRAHAM FIELD www grahamfield com Fabricado en China
12. TANDO PROBLEMAS Si su Neb u Lite LX2 Compresor de Nebulizador falla consulte a la guia de Detectando Problemas debajo Si el problema continua llame a su distribuidor autorizado de Graham Field Causa y Soluci n El aparato no Verifique si el enchufe est conectado correctamente en la toma funciona el ctrica apropiada Cuando el aparato ha estado corriendo continuamente por m s de 30 minutos el protector termal interno puede ser activado para que el aparato se enfr e por 30 minutos antes del pr ximo uso Nebulizaci n es Verifique que tiene el voltaje el ctrico apropiado d bil Verifique la manga para bloqueos o escapes de aire en la conexi n al compresor o la taza de nebulizador reemplace si es necesario Verifique que la taza del nebulizador est armado bien y no da ado Si hay da o reemplace si es necesario Verifique si el filtro est sucio reemplace el filtro JB0112 110 INS LAB RevC14 14 ESPECIFICACIONES Especificacion Presi n Maxima del Compresor Flujo M ximo Tasa del Flujo de Operaci n 010 psi Tasa de Nebulizaci n Tama o de part cula Capacidad Dimensi n LxWxH Requ sito El ctrico Corriente Capacidad de Fusible Cord n El ctrico Enchufe Ambiente Descripci n 30 psi Aproximadamente 14 LPM Aproximadamente 5 5 LPM 0 2 0 3 ml min 11 7 x 6 8 x 4 2 29 8 cm x 17 3 cm x 10 7 cm 4 2 Ib 1 91 kg 120VAC 60Hz 1 03 1 25A tasa 99 1 18A 5 T5A 2
13. a fecha de transporte al Cliente a menos que haya una fecha de expiraci n en el componente en cual la garant a se expira en la per odo de garant a o la fecha de expiraci n OBTENIENDO SERVICIO DE GARANT A La garant a limitada solamente aplica a defectos reportados al Distribuidor de quien el Cliente compro el producto y quienes ellos en turno notifica al equipo de Servicio de Cliente de GF dentro el per odo de garant a aplicable en cuanto ser examinado por GF o un representante autorizado para probar el producto sobre garant a Falta de seguir las instrucciones espec ficas resultara en rechazo de la reclamaci n de garant a Si no hay Distribuidor debes llamar a GF directamente llamando 678 291 3207 mandando fax a 770 368 2386 o por email a cs grahamfield com Direcciones espec ficos se van a dar por el Representante de Servicio De Clientes EXCLUSIONES La garant a no cubre ni GF ser responsable de lo siguiente 1 Defectos da o u otras condiciones causadas por mal uso abuso negligencia alteraci n accidente da o de transporte o falta de buscar y obtener reparo o repuesto en manera puntual 2 Productos con los n meros seriales quitados o desfigurados 3 Productos no instalados utilizados or mantenidos correctamente como requerido en los manuales oficiales del Producto y 4 Cargos de Labor o transporte incurridos en el regreso o instalaci n de partes de reemplace 5 Productos considerados ser consumibles como di
14. cho en este documento 6 Asesor as o partes no pr vidos por GF 7 Cargas por otras personas por ajustamientos reparaciones partes de reemplace instalaci n u otro trabajo hecho en conexi n con este Producto no autorizado en escrito en avanza por GF 8 Cargas y gastos de mantenimiento y limpieza regular y 9 Representaciones y garant as hechos por otras personas o entidades no GF JB0112 110 INS LAB RevC14 16 GARANT A ENTERO REMEDIO EXCLUSIVO Y DESCARGO DE DA OS CONSIGUIENTE ESTA GARANTIA ES LA UNICA GARANTIA DE GF Y ES EN VEZ DE TODAS OTRAS GARANTIAS EXPRESIDAS O IMPLICITADAS GF NO HACE GARANTIAS ENTENTIDOS DE CUAL QUIER MANERA INCLUYENDO GARANTIAS ENTENDIDOS DE COMERCIALIZACION O IDONEIDAD PARA UN PROPOSITO PARTICULAR SI UN MODELO Y MUESTRA SE LE ENSENO A UN CLIENTE TAL MODELO O MUESTRA FUE UTILIZADO SOLAMENTE PARA ILUSTRAR EL TIPO GENERAL Y CALIDAD DEL PRODUCTO Y NO PARA REPRESENTAR QUE EL PRODUCTO SE CONFORME CON ESE MODELO Y MUESTRA EN TODOS RESPETOS TODA RESPONSABILIDAD DE GF POR CUAL QUIER PRODUCTO Y SERVICIO PROVIDO ES LIMITADA AL COSTO DEL PRODUCTO EN LA RECLAMACION EN NO EVENTO EN CONTRACTO INDEMNIZACION GARANTIA NEGLIGENCIA RESPONSABILIDAD ESTRICTA O OTRO QUE GF SERA RESPONSABLE POR CUAL QUIER DANO DIRECTO ESPECIAL INDIRECTO INCIDENTAL EJEMPLAR O CONSIGUIENTES INCLUYENDO PERO NO LIMITADO A DANOS FOR PERDIDA DE BENEFICIO O GANANCIA PERDIDA DE USO INACTIVO O SALARIOS DE EMPLEADOS O TRABAJADORES CONTRACTORE
15. entras estos est n siendo administrado Este aparato no tiene protecci n AP o APG 12 13 14 15 16 17 18 19 20 Conecte este producto solamente en un enchufe de pared correcto Este aparato tiene un enchufe polarizado un aspa es mas ancha que la otra Para reducir el riesgo de electrocuci n este enchufe es dise ado para poder ser posicionado de una sola manera en una toma el ctrica polarizada Si el enchufe no entre completamente en la toma invierta el enchufe Si no funciona de este modo contacte un electricista cualificado No modifique el enchufe de ninguna manera Desconecte el aparato antes de llenar el nebulizador Este aparato no utiliza aceite No lubrique No debe remover el nebulizador de chorro cuando el aparato est operando No debe dejar medicamento en el nebulizador cuando no est en uso Use el nebulizador por periodos el periodo de operaci n m ximo es 30 minutos El nebulizador no debe ser usado por 30 minutos entre usos La boquilla y la m scara opcional son para uso de una sola persona para evitar infecci n no debe compartirlos Aviso para los clientes de California Proposici n 65 de California ADVERTENCIA Este producto contiene una sustancia qu mica conocida en el estado de California por causar c ncer y da os reproductivos o del desarrollo GUARDE ESTAS INSTRUCCIONES JB0112 110 INS LAB RevC14 INTRODUCCION Este manual del usuario contiene informaci
16. information to ensure that you get the most from your product Z DANGER To reduce the risk of electrocution 1 Always unplug this product immediately after use 2 Do not use this product while bathing showering washing dishes or close to water sources of any kind 3 Do not place or store device where it can fall or be pulled into a tub or sink 4 Do not place device in or drop into water or other liquid 5 Do not reach for a device that has fallen into water JB0112 110 INS LAB RevC14 Unplug it immediately A 10 11 12 JB0112 110 INS LAB RevC14 WARNING To reduce the risk of burns electrocution fire or personal injury Never leave this device unattended when plugged in This product contains small parts that may present a choking hazard to small children and the tubing may present a strangulation hazard Always use close supervision when this device is used by or near children or those who require close supervision Children under the age of 3 or any patient who is unable to use a mouthpiece properly under supervision should use a mask Use this device only as intended and described in this manual Do not use attachments or accessories not recommended by GF Health Products Inc Never operate this product if a it has a damaged cord or plug b it is not working properly c it has been dropped or damaged or d it has been dropped into water Return the product to your Graham Field a
17. lack 6 ft 182 9 cm 10 Environment Temperature Storage 5 F to 122 F 15 C to 50 C Storage 10 to 90 RH non condensing Transport 10 to 90 RH non condensing JB0112 110 INS LAB RevC14 15 LIMITED WARRANTY SCOPE OF WARRANTY GF Health Products Inc GF warrants to the original purchaser only that it will replace or repair components at GF s sole discretion that are defective in material or workmanship under normal use and service All warranties are conditioned upon the proper use of the products strictly in accordance with good commercial practice and applicable GF instructions and manuals including proper use and maintenance To the extent that a component is warranted by a third party GF conveys all of its rights under that warranty to the original purchaser to the extent permitted This limited warranty shall only apply to defects that are reported to GF s customer service team within the applicable warranty period and which upon examination by GF or its authorized representative prove to be a warranty item This limited warranty is not transferable The warranted components and time period are set forth below COMPYESSOF ee ne Shee eC aM a five years PC COSSOTIOS nati lod oe ie Rcs six months The applicable warranty period shall commence from date of shipment to the original customer unless there is an expiration date on the component in which case the warranty shall expire o
18. lectrocuci n fuego o heridas a la persona Este producto nunca deber a ser desatendido mientras est conectado Este producto contiene piezas peque as que presenta riesgos de asfixia para ni os y la manga puede presentar riesgo de estrangulaci n Supervisi n cercana es necesaria cuando este producto est utilizado cerca de ni os o personas con impedimentos Ni os menores de 3 a os y cualquier paciente quien no puede usar la boquilla correctamente bajo supervisi n debe usar la m scara Utilice este producto solamente como indicado en el manual de usuario No utilice aditamentos o accesorios no recomendados por GF Health Products Inc Nunca utilice este producto si a elenchufe o el cable est da ado b no funciona adecuadamente c ha sufrido ca da o da o o d ha sido mojado o sumergido en agua Devuelve este producto al centro de servicio para examen y o arreglos Mantenga el cable lejos de superficies calientes Nunca obstruya entradas de aire del producto o utilice en una superficie suave tal como cama o sill n donde las entradas del aire pueden ser bloqueadas Mantenga las entradas libres de pelusa cabello o materiales de este tipo Nunca inserte objetos en cualquier entrada o manga Nunca utilice so oliento o dormido No utilice al aire libre ni opere donde se utilicen productos de aerosol No utilice en presencia de anestesia ox geno oxido n trico o cualquier gas inflamable mi
19. losed equipment without protection against ingress of water A Attention read the instructions Class II not applicable for UL1431 BF This product is in accordance with the degree of protection against electric shock for type BF equipment not applicable for UL1431 Disposal of Electrical amp Electronic Equipment WEEE This product should not be treated as household waste but submitted to an appropriate collection point for the recycling of electrical and electronic equipment For more detailed information about the recycling of this product please contact your local city office household waste disposal service or the Graham Field authorized distributor from whom you purchased this product JB0112 110 INS LAB RevC14 6 PRODUCT DESCRIPTION Features and Components Please note nebulizer features and components labeled in the illustration below T adapter RT lid reservoir mouthpiece gt N A tube E air outlet o compartment N connector ANY filter cap _ AS ON OFF y al nebulizer cup connector tubing Neb u Lite LX2 Nebulizer Compressor Info Neb u Lite LX2 replacement parts are available at www grahamfield com or from your Graham Field authorized distributor JB0112 110 INS LAB RevC14 7 SETUP Info Before initial operation clean the nebulizer cup assembly following the instructions given in MAINTENANCE Cleaning the Nebulizer Cup A
20. lug the compressor from power outlet 8 Disconnect nebulizer from tubing 9 Clean nebulizer as instructed in MAINTENANCE Cleaning the Nebulizer Cup JB0112 110 INS LAB RevC14 10 Safety Overload A NOTICE Do not exceed 30 minutes of continuous operation 1 The motor of this device has a built in thermal overload protector Should the motor overheat the protector will automatically shut off the motor Should this occur move the ON OFF switch to the OFF position and allow the motor to cool down for approximately 30 minutes before turning it on again 2 If the overload protector shuts off the motor frequently you may have an unstable voltage situation 3 If the device shuts down and cannot restart it may need to be replaced Call your Graham Field authorized distributor immediately JB0112 110 INS LAB RevC14 11 MAINTENANCE Cleaning the Compressor s Outer Case Z WARNING Electrical shock hazard Do not remove the outer case of the device All disassembly and maintenance of the device must be performed by a qualified service technician Refer service to qualified service personnel Z WARNING This device does not require oil Do not attempt to lubricate any internal parts Z WARNING Unplug device before cleaning Do not submerge in water for cleaning Wipe the compressor s outer case with a clean damp cloth weekly to keep it dust free Do not use any powdered type cleaners or soap Cleaning the Nebulizer Cu
21. n the earlier of warranty period or the expiration date OBTAINING WARRANTY SERVICE A GF Customer Service Representative must authorize warranty service Please contact the GF Customer Service department by calling 678 291 3207 sending a fax request to 770 368 2386 or by e mailing a request to cs grahamfield com Specific directions will be provided by the Customer Service Representative Failure to abide by the specific directions will result in denial of the warranty claim EXCLUSIONS The warranty does not cover and GF shall not be liable for the following 1 Defects damage or other conditions caused in whole or in part by misuse abuse negligence alteration accident freight damage tampering or failure to seek and obtain repair or replacement in a timely manner 2 Products which are not installed used or properly cleaned and maintained as required in the official manual for the applicable product 3 Products considered to be of a non durable nature including but not limited to casters filters fuses gaskets lubricants and charts 4 Accessories or parts not provided by GF 5 Charges by anyone for adjustments repairs replacement parts installation or other work performed upon or in connection with such products which are not expressly authorized in writing in advance by GF 6 Any labor or shipping charges incurred in the replacement part installation or repair 7 Costs and expenses of regular maintenance
22. nebulizer install medication cup T adapter on cap 10 Connect the tubing s other end to the compressor air outlet connector A WARNING Before use check that all parts are securely connected Use of an improperly assembled nebulizer could diminish or prevent adequate delivery of medication and the effectiveness of the treatment JB0112 110 INS LAB RevC14 9 OPERATION A NOTICE The Neb u Lite LX2 Nebulizer Compressor is designed for intermittent use only Do not operate it continuously for more than 30 minutes for a single use without turning it off and allowing a cooling period of least 30 minutes 1 Ensure that the ON OFF switch is in the OFF position 2 Plug the power cord into a properly grounded electrical wall outlet 3 Move the ON OFF switch to the ON position to start the compressor 4 Place the nebulizer mouthpiece between teeth and close mouth or install the optional mask on face 5 As aerosol starts flowing inhale deeply and slowly through mouthpiece or optional mask Z WARNING Never use a nebulizer with a clogged nozzle If the nozzle is clogged the aerosol mist will be reduced altered or stopped which will diminish or eliminate the effectiveness of the treatment If clogging occurs replace the nebulizer Info If you need to interrupt treatment move the ON OFF switch to the OFF position 6 When the treatment is complete move the ON OFF switch to the OFF position to turn off the compressor 7 Unp
23. oducto est en concordancia el grado de protecci n sobre el el ctrico y electr nico Para m s informaci n detallada sobre el reciclaje de este producto llame a su oficina de cuidad local un servicio de disposici n de residuos dom sticos o a su distribuidor autorizado de Graham Field de donde compr este producto JB0112 110 INS LAB RevC14 6 DESCRIPCION DEL PRODUCTO Caracteristicas y componentes Por favor de tomar nota de las caracteristicas y los componentes del nebulizador descritos en la ilustraci n abajo tapa de almacenaje adaptador T y3 manga de boquilla nh reserva de A al almacenaje Ww enchufe de aire tapa del filtro interruptor de ON OFF taza del nebulizador conector Neb u Lite LX2 Compresor de Nebulizador Info Neb u Lite LX2 piezas reemplazadas estan disponibles en www grahamfield com o de su distribuidor autorizado de Graham Field JB0112 110 INS LAB RevC14 7 ENSAMBLAJE Info Antes de operaci n inicial limpie la taza del nebulizador siguiendo las instrucciones escritos en la secci n Mantenimiento Limpieza de la Taza del Nebulizador N ADVERTENCIA Antes de conectar el cord n de electricidad asegure que el interruptor de ON OFF est en la posici n OFF El enchufe tambi n sirve para desconectar el aparato 1 Antes de uso examine el compresor y taza de nebulizador para da o reemplace
24. or damage can result Z WARNING The disposable nebulizer kit is for single patient use only Storage Keep the device and accessories dry Avoid exposure to direct sunlight JB0112 110 INS LAB RevC14 13 TROUBLESHOOTING If your Neb u Lite LX2 Nebulizer Compressor fails to function consult the following Troubleshooting guide If the problem persists consult your Graham Field authorized distributor Cause and Solution Device doesn t Check if plug is properly fit into a grounded electrical outlet operate When device has been run continuously for more than 30 minutes just before using auto shut down may have been activated by the built in thermal protector ensure that device is OFF for at least 30 minutes before next usage Nebulization is Check for proper electrical voltage weak Check tubing for blockage or air leakage at connection to Neb u Lite compressor or nebulizer cup replace as needed Check that the nebulizer cup is properly assembled and not damaged If there is any damage replace as needed Check if filter is dirty replace filter as needed JB0112 110 INS LAB RevC14 14 SPECIFICATIONS Max flow rate Approximately 14 LPM Operating flow rate Approximately 5 5 LPM 10 psi Nebulization rate 0 2 0 3 ml min Capacity Dimensions LxWxH 11 7 x 6 8 x 4 2 29 8 cm x 17 3 cm x 10 7 cm m a Electrical Requirement 120VAC 60Hz 1 03 1 25A rate 99 1 18A 5 T5A 250V MFG Li B
25. p All parts of the disposable nebulizer except tubing should be thoroughly cleaned after each use If your physician specifies a specific cleaning procedure follow that procedure Z WARNING To prevent possible risk of infection from contaminated medication clean the nebulizer after each treatment 1 After each use disassemble the nebulizer cup T adapter and mouthpiece completely wash all parts in warm soapy water and rinse thoroughly Allow to air dry Store in a clean dry location 2 Once daily after washing as above soak nebulizer components in a fresh solution consisting of one part warm water and one part white vinegar for 30 minutes followed by a warm water rinse Allow to air dry Store in a clean dry location JB0112 110 INS LAB RevC14 12 Replacing the Filter A NOTICE Change the filter once every 30 days or when filter turns gray Info Additional filters can be purchased at www grahamfield com or from your Graham Field authorized distributor 1 No gt PrP PrP nu Ensure that ON OFF switch is in the OFF position Open the filter cap located next to the ON OFF switch Remove the dirty filter with a small pointed object Discard the filter Replace with a clean filter Replace the filter cap NOTICE Do not use cotton or other materials as a filter NOTICE Do not wash or clean the filter NOTICE Do not reuse the filter Do not operate compressor without a filter Compress
26. roducts Inc O 2007 GF Health Products Inc JB0112 110 INS LAB RevC14 2 DIRECTIVAS IMPORTANTES DE SEGURIDAD LEA TODAS LAS INSTRUCCIONES ANTES DE UTILIZAR A PELIGRO Indica una situaci n de peligro o una practica insegura que si no es evitada resultar en muerte o heridas serias a la persona Z ADVERTENCIA Indica una situaci n de peligro o una practica insegura que si no es evitada puede resultar en muerte o heridas serias a la persona N PRECAUCI N Indica una situaci n de peligro o una practica insegura que si no es evitada podr a dar lugar a da os corporales de menor importancia A AVISO Indica una situaci n de peligro o una practica insegura que si no es evitada podr a dar lugar a da os de menor importancia al producto o da os materiales Info Proporciona recomendaciones para la aplicaci n y otra informaci n til para asegurar que obtengas lo m s que pueda del producto N PELIGRO para reducir el riesgo de electrocuci n 1 Siempre debe desconectar este producto inmediatamente despu s de usar 2 No debe usar durante el bano lavando platos y cerca de cualquier fuente de agua 3 No posicionar o almacenar donde pueda caer a la ba era o al lava manos 4 Nodebe introducir en agua u otro liquido No debe recoger producto sumergido en agua Desconecte inmediatamente JB0112 110 INS LAB RevC14 3 A 11 JB0112 110 INS LAB RevC14 ADVERTENCIA Para reducir el riesgo de quemadura e
27. s en la secci n Mantenimiento Limpieza de la Taza del Nebulizador JB0112 110 INS LAB RevC14 10 Seguridad en caso de sobrecarga A AVISO No debe exceder m s de 30 minutos de operaci n continua 1 Este compresor contiene un dispositivo de protecci n termal Si el motor comienza a sobrecalentarse se apagar autom ticamente Si esto ocurre posicione el interruptor a la posici n OFF y permita que el motor se enfri por 30 minutos antes de recomenzar el compresor 2 Si el protector apaga el motor frecuentemente podr a tener una situaci n de voltaje inestable 3 Si el aparato se apaga y no se enciende puede ser necesario reemplazarlo Llame a su proveedor inmediatamente JB0112 110 INS LAB RevC14 11 MANTENIMIENTO Limpieza de la Carcasa del Compresor A ADVERTENCIA Riesgo de electrocuci n No remueve carcasa externa de este aparato Todo desensamblaje y mantenimiento de este aparato debe ser realizado por un t cnico de servicio cualificado N ADVERTENCIA Este aparato no necesita aceite No lubrique piezas internas Z ADVERTENCIA Desenchufe el aparato antes de limpiar No sumerja bajo agua Frote con un pa o h medo cada semana No utilice detergentes en polvo o abrasivos que pueden da ar la carcasa Limpieza de la Taza del Nebulizador Todas las piezas del nebulizador desechable excepto la manga deben ser limpiados despu s de cada uso Si su m dico le da un procedimiento especifica de limpieza
28. si es necesario 2 Posicione el aparato en una superficie horizontal para que los controles est n con f cil acceso No debe usar este aparato en el piso 3 Remueva la tapa de la taza del nebulizador 4 Inserte medicamento prescrito por su m dico 5 Re ne taza y tapa 6 Si usa la boquilla para el tratamiento proceda al paso 7 Si usa la m scara opcional instale la parte inferior de la m scara directamente sobre la tapa de la taza del nebulizador como demostrado a la derecha entonces proceda al paso 9 7 Conecte la boquilla a la parte grande del adaptador T JB0112 110 INS LAB RevC14 tapa BE s 4 ensamblaje de taza y tapa A j m scara dia tops bud instale la m scara en la tapa adaptador T V ensamblaje de adaptador T y boquilla Info La manga de reserva en la ilustraci n superior del manual es como un tanque de retenci n para reducir la cantidad de medicamento perdido durante tratamiento Es opcional Si desea usar la manga de reserva posicione en la parte inferior del adaptador T 8 Instale el adaptador T Cok sobre la tapa de la taza del y adaptador T nebulizador A taa 9 Conecte la manga al adaptador instale A ador ala parte inferior de la taza en tapa de la taza nebulizador 10 Conecte la otra parte de la manga al conector de mango del compresor Z ADVERTENCIA Antes de uso verifique que todas las piezas estan conectados correctamente
29. ssurance except those set out in this document For additional information on this product or this warranty please contact a GF Customer Service Representative NOTES 1 Additional terms and conditions may apply 2 Freight claims must be notated on the Bill of Lading and must be made with immediacy The ICC regulations govern specific requirements for freight claims Failure to abide by those regulations may result in a denial of the freight claim GF will assist you in filing the freight claim 3 Claims for any short shipment must be made within thirty 30 days of the invoice date JB0112 110 INS LAB RevC14 17 Manufactured for GF Health Products Inc 2935 Northeast Parkway Atlanta Georgia 30360 USA Telephone 770 368 4700 Fax 770 368 2386 GRAHAM FIELD www grahamfield com Made in China JOHN BUNN Neb u Lite LX2 E305033 Compresor de Nebulizador Modelo JB0112 110 Manual de Usuario Lea antes de operar el nebulizador Guarde este manual para referencia en el futuro A La Ley Federal USA restringe este aparato para ventas por la orden de su m dico Este aparato no debe ser utilizado si el operador no ha sido adiestrado por profesional de cuido de salud cualificado JB0112 110 INS LAB RevC 14 Este producto ha sido examinado y aprobado con los siguientes estandares UL1431 EN 60601 1 EN 60601 1 2 C 0197 CONTENIDOS Lata tddi 8 DIRECTIVAS
30. uthorized distributor for examination and repair Keep the cord away from heated surfaces Never block the air openings of this product or place it on a soft surface such as a bed or couch where the air openings may be blocked Keep the air openings free of lint hair and the like Never drop or insert any object into any openings or hose Never use this device while drowsy or sleeping Do not use this device outdoors or operate where aerosol spray products are being used Do not use this device in the presence of flammable anesthesia or where oxygen or nitrous oxide is being administered This device has no AP or APG protection Connect this device to a properly grounded outlet only 13 14 15 16 17 18 19 20 This device has a polarized plug one blade is wider than the other As a safety feature this plug will fit into a polarized outlet only one way If the plug does not fit fully into the outlet reverse the plug If it still does not fit contact a qualified electrician Do not modify the plug in any way Do not attempt to defeat this safety feature Unplug the device before filling or cleaning the nebulizer This device is oil free Do not lubricate Do not remove the jet nebulizer while the device is operating Do not leave medication inside the jet nebulizer when it is not in use Use the nebulizer intermittently the maximum operating period is 30 minutes The nebulizer must stand unused for 3

Download Pdf Manuals

image

Related Search

Related Contents

English (UK)  TEFAL FR405030 Instruction Manual  User Manual - Rohrback Cosasco Systems  DECISION N°12 SP/PC/ARPT/2013 du 30 /01 /2013  TP-Link TG-3468 User's Manual  取扱説明書/1.2MB  Operating Guide PSI 8000 T Power Supply Series - eps  válvulas de bola xanik® tipo trunnion  Manuel TOWER 2 x 5 Litres  Manuel d`utilisation  