1. Page4 2 QD2300 5 AvantGuardO Electric bed User Manual Raising the TotalGuard integrated siderails position 2 The siderails are located under the bed when not in use To raise a siderail Pull the folded siderail outwards and upwards until it latches into the locked position as close to the edge of the mattress as possible without forcing Verify the siderail is locked by pulling on the siderail Lowering the TotalGuard siderails position 1 To lower a siderail Make sure that the foot siderail is folded Gripping the siderail by the handles push it slightly inwards 1 Activate the unlocking button on the siderail 2 Rotate the siderail downwards into the required low position 3 and release the unlocking button QD2300 5 AvantGuard Electric bed User Manual Page4 3 Unfolding the foot siderails position 3 A CAUTION The foot section of the siderail must only be unfolded when the head section of the siderail is locked in the raised position Failure to do so could result in equipment damage To unfold the foot section of the siderail Grip the outer foot section of the siderail and rotate it to the foot end Position the siderail in the support The siderail is secure when it clicks into place Verify the siderail is locked by trying to lift the foot section Page4 4 QD2300 5 AvantGuardO Electric bed User Manual Stor
2. Page 6 6 QD2300 5 AvantGuard Electric Bed User Manual To fit a monitor stand Unscrew the two knobs from the frame Fit both ends of the frame into the sockets at the same time Fitthe knobs through the under side of the socket and tighten Pivot the stand as shown in the photo below so that it is above the sleep surface Oxygen Cylinder Holder AC959A AD1014A AD102A Safe working load 15 kg The oxygen cylinder holder is designed to accept an oxygen cylinder and must only be fitted on the patient helper supports at the head end of the bed outside the sleep surface It can be rotated through 90 Each type of holder corresponds to a cylinder model and must never be used with a different cylinder See below AC959A for AD101A for AD102A for cylinder model cylinder model D cylinder model E B5 0140 00100 60100 1 The safe working load specifications allow for a substantial safety margin QD2300 5 AvantGuard Electric Bed User Manual Page6 7 Ad WARNING The following recommendations are designed to prevent any possible incidents so that this accessory can be used in optimum safety conditions for both the patient and nursing staff Check that the cylinder is correctly positioned at the base of the cylinder holder Never use a different oxygen cylinder model from the model that is specified above danger of dropping the cylinder or interfering with various operations
3. Page 9 2 QD2300 5 AvantGuard Electric Bed User Manual Specifications Maximum Head Thigh Foot Reverse inclination with section section section Lu k AIR Trendelenburg orizonta 65 436 23 16 16 NOTE These are average values which may vary according to manufacturing tolerances d T B g QD2300 5 AvantGuard Electric Bed User Manual Page9 3 Warranty and after sales service conditions The warranty for our beds will be rendered null and void in part or in total in the event of Unauthorized interference with or incorrect maintenance of e actuators electrical drives and components e mechanical systems any abnormal use use of parts and accessories not authorized by the manufacturer use of unauthorized cleaning procedures any use including cleaning and servicing that does not comply with the instructions in this manual The details of after sales service contacts in your country are shown on the back of this manual Compliance CE NF MEDICAL Hospital beds compliant authorization N NF178 01 01 33 MEDICAL Complies with standards NF S 90 312 1984 e EN 60601 1 1996 e EN 60601 1 2 2001 EN 60601 2 38 1999 e EC 60601 2 38 Amendment 1 1999 Complies with essential requirements of EC directive 93 42 EEC applicable to class I medical equipment Page 9 4 QD2300 5 AvantGuard El
4. The bed should be inspected at least once a year to keep it in good condition and working properly More frequent inspections may be necessary depending on the use made of the bed If the bed is in storage and it is equipped with a battery it must be charged every 3 months to prevent failure of the battery Page 5 8 QD2300 5 AvantGuard Electric Bed User Manual The following points should be given particular attention braking system and wheels Siderail locking mechanisms and foot siderail supports Drive systems especially actuators etc electrical function management and lockouts head and thigh sections Trendelenburg ReverseTrendelenburg and their accessories CPR release and emergency functions cables and handles bed movement and ancillary part bearings brake steer bar operation in particular return to neutral the condition of cables and electrical components in particular power cable correct earthing of the bed s metal parts and equipotential connectors waterproofing of electrical connections tears damage cable ways good condition of the frame and welded assemblies corrosion and shocks The locking system of the siderail The locking system of the TotalGuard foot siderail support bracket The locking system of the TotalGuard foot siderail support YES YES YES The entire electrical system should be inspected by an approved after sales service person on an average of once every three y
5. SK KK RR KK KK 4 32 Equipotential terminal 0 000 000 0005 4 33 Handling the headboard and footboard 4 33 Sleep surface kas hs dace s k bck r Er REP d 4 37 AvantGuard Electric Bed User Manual QD2300 5 Page i Restraining strap handles LA KK RR KK KK 4 37 Foot End Bed Extension WAK KK KK KK KK KK KK KK 4 39 Linen holder citer sistere RR ERR 4 40 Battery b ckup un sin l k ERR tS ew 4 41 MobiBar egress handle 0 000000 4 42 Control unit on a flexible arm 005 4 43 Control Pendant 0 0 eee kek ehe eee 4 44 Accessory support bar LV KK KK KK KK KK KK KK eee 4 46 Medical device support rail ALA SS SR KK KK 4 47 Chapter 5 Cleaning maintenance and spare parts Cleaning n e NA eL Ree see OU NAR 5 1 General Cleaning hun h AA Ziq ab W eese 5 1 Safety Recommendations KK KK RR KK KK 5 1 General Advice sis K k abe kula l Ga EUER E E RE 5 2 steam Cleaning yaw K k Re b eer ER Ek 5 3 Cleaning tough stains LA KK KK KK KK KK KK KK KK KK 5 3 Disinfectmng d Dope Eee Haya epe eps 5 3 Maintenance 5 yasa a Lee oC UR AU Sed CS 5 8 Safety Recommendations 00 00 0020 ee 5 8 Preventive Maintenance 02 e KK KK KK KK KK KS 5 8 Chapter 6 Accessories ACCESSORIES o 25ya a a pa k egtb mc ob AN bA 0A ds 6 1 Patient Helpe
6. until the required angle is reached then release QD2300 5 AvantGuard Electric bed User Manual Page 4 23 Manual foot section adjustment The foot section has a gas assisted locking system that can be manually adjusted NOTE The angular range that the foot section can be adjusted to depends on the angle to which the thigh section is adjusted To incline the foot section e Use the pull out handle on the end of the foot section to raise it to the required position 1 Raise or lower the foot section to the required position 2 Release the handle a o esp Mek Page 4 24 QD2300 5 AvantGuard Electric bed User Manual Automatic EasyChair The EasyChair automatic chair position allows the patient to be progressively mobilized without the need for transfer from the bed This function is only available to the caregiver Adjusting to the chair position Activate the function management See Activating deactivating function management page 4 14 Press the EasyChair automatic chair position button A until the chair position is reached The movement stops automatically To return to the normal position Press the return to flat sleep surface button B until the normal position is reached The movement stops automatically Deactivating function management NOTE The bed can be adjusted to the chair position from any sleep surface height
7. Page 4 16 QD2300 5 AvantGuard Electric bed User Manual Control unit on a flexible arm Raise Lower To adjust the height of the sleep surface Press the arrow of the symbol for the movement you require Release when the required height is reached Bilateral HiLow pedal This pedal is located centrally under the lower bed frame on each side By default the pedal is locked to avoid accidental movement It is necessary to unlock the HiLow pedal before each use NOTE The HiLow lock out 1 on the side caregiver unit does not control the availability of the HiLow pedal To adjust the height of the sleep surface Activate function management See Activating deactivating function management page 4 14 Press your foot on the corresponding control arrow for the movement you require Release when the required height is reached Deactivate function management to lock the HiLow pedal QD2300 5 AvantGuard Electric bed User Manual Page 4 17 Low bed position indicator An indicator located on the control pendant and on the control unit on the flexible arm switches off to indicate that the bed is in low position This position is recommended when the patient is left unattended A WARNING When raising the bed make sure that there is enough room above the IV pole if necessary Failure to do so could result in patient injury or equipment damage Page 4 18 QD2300 5 AvantGua
8. QD2300 5 AvantGuardO Electric bed User Manual Page4 9 Removing a lonq metal siderail To lower a long metal siderail Lower the siderail See Lowering the long metal siderails position 1 page 4 9 On the head side pull 1 the release pin then pull 2 out the siderail without removing it completely from its support On the foot side pull 3 the release pin then pull 4 out the siderail without removing it completely from its support Grip the siderail and remove it Raising a long metal siderail To raise a long metal siderail Grip the siderail and position it in the head and foot supports Push on both pins until a click is heard Check that the siderail is locked by pulling it Check the correct operation of the siderail by lowering and raising it Page 4 10 QD2300 5 AvantGuard Electric bed User Manual Electrical Functions The bed s power driven features are accessed by a control pendant a bilateral HiLow foot pedal or a control unit on a flexible arm Certain emergency functions are available on the lateral caregiver unit Control Pendant 4 WARNING Nursing staff need to assess whether the patient can be left unattended with the control pendant Failure to do so could result in patient injury or equipment damage The bed can be equipped with a control pendant for the patient and a control pendant for the nursing staff The control pendant provides access to th
9. Transport Storage All the necessary precautions must be taken to ensure that the bed and its accessories are shipped and stored in complete safety under optimal conditions The following conditions must be met During shipment the bed must be When stored the bed must be in the low position in the low position all electrical functions locked out all electrical functions locked out covered brakes applied and all moving parts secured covered brakes applied protected from fluid ingress protected from fluid ingress at a temperature of between 10 and 50 C 14 and 122 F temperature between 10 and 50 C 32 and 104 F Humidity 20 to 80 at 30 C 86 F Humidity 20 to 80 at 30 C 86 F pressure 500hPa to 1060hPa 0 to 2000m pressure 500hPa to 1060hPa 0 to 2000m a Shipment means the moving of the bed between facilities not patient transfer within the facility During shipment or storage beds should not be stacked one on top the other QD2300 5 AvantGuardO Electric Bed User Manual Page7 1 Use The bed must be used in the following conditions temperature between 0 and 104 00 F 432 and 104 F Humidity 20 to 80 at 30 C 86 F pressure 700hPa to 1060hPa 0 to
10. 2000m Ad WARNING If the bed is equipped with a battery and the bed is stored for long periods of time the battery must be charged every 3 months Ignoring this recommendation risks damaging the battery and the unavailability of functions without AC power NOTE Before use refer to First Steps page 3 1 Page 7 2 QD2300 5 AvantGuard Electric Bed User Manual Chapter 8 Safety tips and precautions Safety Tips Brake and steer A CAUTION Risk if not locked The patient may fall if he leans on the bed to get in or out of the bed Ensure that the brakes are applied if the bed is not to be moved or if the patient is to be left unattended See Brake and steer system page 4 Try moving the bed to ensure that the wheels are locked Patients should be moved with the bed in mid hilow position by two people Ensure that the accessories patient helper I V Pole etc will not interfere with progress through doorways other passages or overhead lights Ensure that the power cable is disconnected and correctly secured See Securing the power cable page 4 32 Bed Position The bed should be kept in the lowest hilow position to help to reduce the risk of patient falls especially when left unattended Use the HiLow feature of the sleep surface to adjust the bed to the required height when the patient is undergoing treatment Trendelenburg Reverse Trendelenburg and Emerge
11. Please refer to the fitting instructions provided with the accessory when fitting the accessory For usage refer to Activating deactivating function management page 4 14 QD2300 5 AvantGuard Electric Bed User Manual Page 6 13 Long metal siderails AD178A Ad WARNING The accessory must be fitted by an authorized technician Failure to do so could result in patient injury or equipment damage Please refer to the fitting instructions provided with the accessory when fitting the accessory For usage refer to Long metal siderails page 4 7 Mattress For more effective and safer use of this bed Hill Rom recommends mattresses that follow the safety recommendations in Mattress page 8 4 The AvantGuard bed can be used optimal conditions of comfort and safety by choosing one of the mattresses described in paragraph Accessories page 2 10 Other mattresses that meet the conditions can also be used Make sure that the bed mattress combination obeys the safety instructions shown in paragraph Mattress page 8 4 Page 6 14 QD2300 5 AvantGuard Electric Bed User Manual Accessory holder ADO016A AD127A AC908A AC932A AD126A AC991A AC961A AC938A Page 6 15 QD2300 5 AvantGuardO Electric Bed User Manual NOTES Page 6 16 QD2300 5 AvantGuard Electric Bed User Manual Chapter 7 Shipment storage and usage
12. To store reverse the steps above Linen holder with wooden endboard To use the linen holder Pull on the board located under the footboard Tip the wire guard backwards To store reverse the steps above 1 Safe working load specification allowing for a substantial safety margin Page 4 40 QD2300 5 AvantGuard Electric bed User Manual Battery backup Power indicator A power indicator A on the control pendant or the control unit on a flexible arm indicates when it is ON that the bed is under power battery or main It switches OFF when the bed is unplugged or in sleep mode Battery power activation Before using the battery the switch B must be enabled on the control pendant or the control unit on a flexible arm All electrical functions are then available in their initial locked state B NOTE Battery power automatically cuts out about one minute after the last movement When the battery charge level is low and an electrical function is activated an alarm will sound indicating that the battery needs re charging The ongoing movement will be completed The bed must then be connected to a mains power supply to re charge the battery The electric functions can then be used normally Battery recharge Ad WARNING The bed must be connected to the mains power supply until the charge indicator goes out Charging time is approximately 10 hours Failure to do so could result
13. damage Page 4 38 QD2300 5 AvantGuard Electric bed User Manual Foot End Bed Extension Ad CAUTION Ensure that the bed extension is correctly secured when storing or extending it by pulling or pushing Failure to do so could result in equipment damage Foot end bed extension with polypropylene endboard To pull out the extension Lift the handle located under the footboard Pull out the extension Two positions are provided Stored and extended The extension is securely held in position by notches To store the extension follow the same process but push the extension in Extension with wooden endboard To pull out the extension Lift the handle located at the foot end of the sleep surface on the inside of the footboard Pull out the extension Two positions are provided Stored or extended Each position is secured in a notch To store the extension follow the same process but push the extension in QD2300 5 AvantGuard Electric bed User Manual Page 4 39 Linen holder A WARNING Do not sit on the linen holder or use it as a step Failure to do so could result in patient injury or equipment damage The bed features a linen holder that is built into the foot end Safe working load 33 07 Ib x Linen holder with plastic endboard To use the linen holder e Lift and pull on the board located under the footboard Tip the wire guard backwards
14. head section when folding away the TotalGuard siderail See Storing the foot siderails Position 2 page 4 5 or is removed when folding away the metal bar See Lowering the long metal siderails position 1 page 4 9 If it is on the outside it may damage the control wire of the siderail A WARNING Do not clip the control pendant on the side opposite to its connection The control pendant can be fitted to the siderails in several places and facing the inside or outside of the bed for greater comfort for the patient and the caregivers QD2300 5 AvantGuardO Electric bed User Manual Page4 45 Unclipping To unclip the control pendant reverse the installation procedure described in the section Installation page 4 44 Connecting the control pendant The control pendant can be connected to the right or left of the patient except if an accessory control unit a flexible arm is fitted on the bed Accessory support bar 4A WARNING Ensure that any accessories fixed to the accessory support bar will not obstruct the base frame and the HiLow pedal This accessory is mounted on the side of the bed and can be adjusted laterally A by pushing or pulling the accessory support bar era This bar allows various devices drainage bag etc as well as some other Hill Rom accessories to be supported Hill Rom See Accessory holder page 6 15 Page 4 46 QD2300 5 AvantGuardO Electric bed User
15. is not an emergency function and is only available for the nursing staff via the electrical function management NOTE If the electrical function management is not manually deactivated it locks itself after about one minute NOTE Do not fix a strap on the pedal or leave an object below it which could activate the management key because if the management function remains activated permanently the HiLow function is no longer available 4 WARNING It is the responsibility of the nursing staff to authorize the patient to use certain bed functions including the HiLow Failure to do so could result in patient injury or equipment damage Page 4 14 QD2300 5 AvantGuard Electric bed User Manual Locking out electrical functions Activate function management Press the symbol representing the function to be locked out on the caregiver s side control panel The indicator of the corresponding function will then be lit to indicate that the function is locked out 4 Deactivating function management Authorizing electrical functions Activating function management Press the symbol representing the function to be authorized 3 on the caregiver s side control panel The indicator of the relevant function will then switch off to indicate that the function is enabled 4 Deactivating function management NOTE Locking out the thigh section adjustment control will also lock
16. lightly dampened cloth and ordinary disinfectant Do not use excessive liquid The bed has been designed for easy cleaning and optimized disinfecting Safety Recommendations 1 Ensure that the bed cannot move 2 Set the bed to the high position 3 Lock out all electrical functions 4 Disconnect the bed and stow the power cable see Securing the power cable page 4 32 QD2300 5 AvantGuard Electric Bed User Manual Page 5 1 5 Ensure that all connections on the control units are firmly in place control pendant and control unit on a flexible arm on the lateral caregiver unit 6 Never pour water on the bed use a high pressure hose or wash in a tunnel wash 7 Never use water at a temperature of over 60 C 140 F 8 Avoid getting excess water on connecting plugs lateral caregiver units control units on the siderail supports and on the mattress 9 Thoroughly dry the bed before reusing it Failure to implement one or more of these recommendations may lead to damage or deterioration preventing use of the bed and rendering the warranty void General Advice NOTE Staining disinfectant products such as methylene blue or eosine must be removed rapidly to avoid permanent staining NOTE A list of recommended cleaning products for all types of cleaning requirements is available on your request along with a special maintenance advice leaflet Avoid excessive temperature differences between the water
17. on the Foot TotalGuard Siderail Support Label This label shows how to verify the locking mechanism on the foot TotalGuard siderail support Do Not Store label GA This label indicates that nothing should be left on the frame No Hand Placement Label This label shows where hands should not be placed Headboard Positioning and Equipotential Terminal Label This label shows how the position of the polypropylene headboard can be checked and where the equipotential terminal is located Page 2 2 QD2300 5 AvantGuard Electric Bed User Manual Egress handle Usage Label This label indicates the storage of the MobiBar Egress handle Interference label MobiBar and TotalGuard Never deploy the foot section of the TotalGuard integral siderail when the MobiBar egress handle in position Locking mechanism on the long metal siderail This label shows how to verify the locking mechanism on the long metal siderail Unlock long metal siderail label This label indicates how to unlock the long metal siderail QD2300 5 AvantGuardO Electric Bed User Manual Page2 3 Locking mechanism installation metal siderail label T XS e A gt This label shows how to verify the locking mechanism during the installation of the lo
18. required angle is attained e Deactivate the function management See Activating deactivating function management page 4 14 QD2300 5 AvantGuardO Electric bed User Manual Page 4 19 NOTE After one minute the management function is deactivated automatically Reverse Trendelenbug Reference mark for positioning the patient Position the patient s hip opposite the mark on the inner surface of the TotalGuardTM siderail to make sure that the patient is in an optimal and comfortable position on the bed Page 4 20 QD2300 5 AvantGuard Electric bed User Manual Head section 4 WARNING Ensure that there are no obstacles patient s limb power cable objects and accessories before using the head section features Failure to do so could result in patient injury or material damage Head section control Head section adjustment can be activated from the control pendant or the control unit on a flexible arm Press the head section raise button A to raise the head section with the automatic contour feature if enabled Release the button when the required angle is attained The head section is lowered using button B The angle between the head section and the horizontal can be seen on the indicator C located on the head siderail QD2300 5 AvantGuardO Electric bed User Manual Page 4 21 Automatic Contour The automatic contour feature automatic comfort level posit
19. the cover Place the small wings of the cover in the spaces A Rotate 1 the cover around the pivot Place the clips on the pivot B and push 2 to bottom until it locks in place QD2300 5 AvantGuard Electric Bed User Manual Page 5 7 Maintenance Safety Recommendations A WARNING Only facility authorized personnel should perform maintenance Failure to observe this precaution could result in patient injury or equipment damage Before any maintenance or repair work carry out the following operations in the order presented Lock out all electric functions see Locking out electrical functions page 4 15 Unplug the bed from the mains power supply Ensure that the bed cannot move Secure the frame and ensure that all movements are locked Never open heat or pierce an electrical actuator or gas actuator high pressure cylinder Contact our after sales service for any specific maintenance problem leaks blockages etc If the bed is fitted with a battery e Never open burn or immerse a worn out battery See De commissioning page 8 8 A new battery should only be installed by facility authorized personnel Never leave the covers open Preventive Maintenance NOTE Maintenance visit frequency should be determined according to the condition of the bed and specific usage as some components may need changing after a given period of use see Service Manual
20. Manual Medical device support rail A WARNING Ensure that there can be no obstruction with the base frame and HiLow pedal As a reminder any user who attaches a medical device to the support must ensure that the resulting combination and or system is compatible For any powered medical device compliance with electrical safety regulations must be checked by qualified personnel This accessory is mounted on the side of the bed and can be adjusted The rail is used to carry various medical appliances and other accessories Hill Rom See Accessory holder page 6 15 QD2300 5 AvantGuardO Electric bed User Manual Page 4 47 NOTES Page 4 48 QD2300 5 AvantGuard Electric bed User Manual Chapter 5 Cleaning maintenance and spare parts Cleaning Ad WARNING Follow the cleaning product manufacturer s instructions Failure to do so could result in patient injury or equipment damage E SHOCK HAZARD Unplug the bed from the mains power supply Patient injury or equipment damage could result a SHOCK HAZARD Do not expose the bed to excessive moisture that would allow for liquid pooling Patient injury or equipment damage could result A CAUTION Do not use harsh cleaners or detergents such as scouring pads and heavy duty grease removers or solvents such as toluene xylene or acetone Equipment damage could occur with an impact on user safety General Cleaning Clean the bed with a
21. Min TotalGuard siderail width with siderails up e 1000 mm Max TotalGuard siderails width with siderails up e 1060 mm TotalGuard M siderails width with siderails down e 970 mm Long metal Siderails width e 996 mm Bed width with polypropylene endboards E 990 mm Bed width with MedispaceTM endboards E 1045 mm Bed width with S quoia endboards E 1045 mm Bed width with Medic hotelTM endboards E 1000 mm Bed length with extension and polypropylene endboards L 2405 mm Bed length without extension and polypropylene 2225 mm endboards L Bed length with extension and wooden endboards L 2400 mm Bed length without extension and wooden endboards L 2220 mm Minimum height single band 150mm diameter casters h 415 mm Minimum height single band 125 mm diameter casters h 393 mm Maximum height single band 150 mm diameter casters H 815 mm Maximum height single band 125 mm diameter casters H 793 mm a All bed versions can pass through doorways with a clearance greater than 1050 mm when the siderails are down b According to features chosen c Extension fully extended d Add 5 cm for a bed equipped with the Hi Low 45 to 85 cm function E e j j C N hm 7 p ice 4m Mist eom e ere EE TUS RS T ur x a
22. NOTE The locking out of one sleep surface function will automatically disable the EasyChair Automatic Chair Position function NOTE If the EasyChair Automatic Chair Position is enabled all the electric movement functions are then automatically enabled QD2300 5 AvantGuard Electric bed User Manual Page 4 25 Emergency functions Emergency Trendelenburg This feature automatically and simultaneously lowers all the articulated sections until they are horizontal then inclines the sleep surface to an angle of 0 to 16 4 WARNING Before setting in the Shock position it is imperative to lower the siderails A CAUTION Ensure that any accessories or devices cannot fall as a result of the frame movement Failure to do so could result in equipment damage Ad WARNING Never allow an unqualified person or unattended patients to use this function in this position Failure to do so could result in equipment damage or injury Before using this function check that no obstacles e g objects accessories power cables or persons are under the sleep surface To enable the Shock feature On the lateral caregiver unit push and hold the symbol A until the desired angle is achieved then release The bed is then in the Shock position NOTE When there is no mains power supply this feature is available through an emergency Trendelenburg battery Page 4 26 QD2300 5 AvantGuard Electric bed Use
23. User Manual AvantGuard Electric Bed LI158Bx 1200 Hill Rom A HILLENBRAND INDUSTRY QD2300 Rev 005 Manufacturer Hill Rom S A S B P 14 Z I du Talhou t 56330 PLUVIGNER FRANCE Tel 4 33 0 2 97 50 92 12 Fax 33 0 2 97 50 92 03 www hill rom com Fifth edition First printing 2003 Printed in Europe QD2300 Rev 005 April 2005 The information in this manual is confidential and may not be disclosed to third parties without the prior written consent of Hill Rom Hill Rom AvantGuard Cliniplot III Duo 2 EasyChair and MobiBar are registered trademarks of Hill Rom Services Inc Clinisert 2 Medic hotel Medispace Primo and TotalGuard are registered trademarks of Hill Rom Services Inc Hill Rom reserves the right to make changes without notice in design specifications and models The only warranty Hill Rom makes is the express written warranty extended on the sale or rental of its products Some of the photographs in this manual are not contractual To order additional copies of this manual refer to the last page of this manual for your national Hill Rom representative and place a parts order for part number QD2300 2003 2005 by Hill Rom Services Inc ALL RIGHTS RESERVED QD2300 5 AvantGuard Electric Bed User Manual Table of Contents Chapter 1 Symbols destination Symbol Definition 0 0 0 KK KK KK KK KK KK KK KK KK KK 1 1 General Sy
24. WARNING Incorrectly installing the headboard in the bed frame may increase the risk of becoming trapped Failure to follow these recommendations may lead to material damage or injury NOTE Position the headboard as shown on the label on the head end cross bar of the bed and the illustration above Page 4 34 QD2300 5 AvantGuard Electric bed User Manual Standard headboard and footboard No special tools or devices are required to remove and replace the standard headboard or footboard To position a standard endboard Hold the endboard by both handles Place the studs in the holes in the head or foot of the bed To remove a standard endboard Hold the footboard by the handles on either side and pull upwards Lockable Footboard The footboard can be fixed to the bed frame with a manual locking system and can be dismount for cleaning Ad WARNING Regularly check that the footboard is correctly fixed To fix the footboard Hold the endboard by the handles and place the studs in the holes in foot of the bed Tighten and lock the two knobs Ensure that the footboard is correctly fixed by lifting pulling or pushing it To remove an endboard Loosen and unscrew the two knobs Hold the footboard by the handles on either side and pull upwards QD2300 5 AvantGuard Electric bed User Manual Page 4 35 Wooden endboards No special tools or devices are required to r
25. afety It is thus the responsibility of the nursing staff to authorize the patient to use certain bed functions including the HiLow Parts and accessories A CAUTION Never modify the bed without the manufacturer s prior consent Alterations could result in injury to the patient or damage to the bed Only use manufacturer s parts and accessories Patient helpers Suitably qualified medical personnel must determine if the patient helper can be left at disposal or not of patients suffering from particular behavioral conditions e g not limited to but including agitation mental confusion or loss of sense of direction behavioral disorders or weakness and that in order to use the bed in best safety conditions Electrical safety precautions SHOCK HAZARD When direct intravascular or intracardiac connections are in use the electric potentials of all the unprotected metal parts need to be equalized The bed must be connected to the mains power supply l QD2300 5 AvantGuard Electric Bed User Manual Page 8 5 Y SHOCK HAZARD In an environment where the electrostatic discharges are prevalent we recommend using our antistatic casters All power connections must comply with standards as defined in See Connection to the Mains Power Supply page 3 2 In compliance with standards relating to electromagnetic interference for medical equipment this product does not interfere with other medical dev
26. ails AD179A Enable control pedal QD2300 5 AvantGuard Electric Bed User Manual Page 2 11 NOTES Page 2 12 QD2300 5 AvantGuard Electric Bed User Manual Chapter 3 Installing the bed Installing the Bed First Steps Before using the bed it is essential to have a thorough understanding of this manual This manual contains instructions for general use and maintenance and guarantees improved safety Caregivers must have access to this manual Caregivers must be informed of the risks that may be encountered in the use of electric beds The many sources and types of accessories hardware or medical devices that may be used together with this bed do not enable Hill Rom to guarantee both the safety and conformity of all the combinations thus created The operator who creates these device combinations must therefore ensure that security and conformity requirements are met Before installing the bed for the first time or after bringing the bed and its accessories out of storage ensure that the bed and its various parts are at room temperature connect the bed to the mains power supply See Connection to the Mains Power Supply page 3 2 make sure that all the moving parts are in good working order make sure that the bed has been cleaned and disinfected See Cleaning page 5 1 QD2300 5 AvantGuard Electric Bed User Manual Page 3 1 Connection to the Mains Power Supply The
27. al Retractable siderail on each side on each side support with lock and bed frame incline angle indicator Identification label Removable i j Fixing points for metal siderails straps 2 I V pole and patient helper sockets 2 I V pole ok 150 mm diameter sockets double band casters Electrical function management Bumper 4 Shock position Hilow pedal Integrated linen Enable control self steering Sth wheel Central brake and steer holder pedal or controlled 5th wheel bar control Equipment varies depending on bed model Page2 8 QD2300 5 AvantGuard Electric Bed User Manual Standard Features Sleep surface dimensions 90 x 200 cm Frame Polypropylene hard surface Yes Selective electrical function lockout Yes Electrical adjustable Trendelenburg Reverse Trendelenburg Yes Adjustable head section Damped CPR release Yes Comfort adjustment Yes Adjustable thigh section Power driven with autocontourYes Central brake and steer system Yes Equipment varies depending on bed model Adjustable foot section Mechanical Electrical Automatic EasyChair Emergency Trendelenbug mandatory requirement for acute care beds Adjustable HiLow From 40 to 80 cm From 45 to 85 cm Without siderails Integrated siderails TotalGuard Long metal siderails Battery backup Control pendant patient Control pendant nursing staff Control unit on flexible arm Bilateral HiLow pedal Enable c
28. and the actuators Bed and accessories See Recommended Cleaning and Disinfection Method page 5 3 e Polypropylene parts See Recommended Cleaning and Disinfection Method page 5 3 After removing the hard surfaces and moving them away from the bed they can be washed in running hot water Endboards and siderails See Recommended Cleaning and Disinfection Method page 5 3 The following products should not be used chlorine formaldehyde or phenol based products and solvents of any kind Never use abrasives cleaning powder or cleaning pads that may damage components Page 5 2 QD2300 5 AvantGuard Electric Bed User Manual Steam Cleaning A CAUTION Do not use any steam cleaning device on the bed Excessive moisture can damage mechanisms in this bed Cleaning tough stains To remove tough stains use standard household cleaners and a soft bristle brush To loosen heavy dried on soil or excreta you may first need to saturate the spot Disinfecting Dilute disinfectants and germicides as specified on the manufacturer s label The following recommendations are not designed to replace existing cleaning protocols drawn up by the hygiene officer or by other bodies for your hospital The disinfecting method described below applies specifically to the bed and its accessories and is designed to save time and to help combat nosocomial infection more effectively Recommended Materials and Product
29. atient handle is over the bed Incorrect position Correct position Adjustable Patient Helper AD081C Safe Working Load 75 kg The adjustable patient helper three positions can be fitted into either of the square sockets at the head end of the bed Place the patient helper in the socket so that the patient handle is over the bed and so that the patient helper arm is in the normal egress position see photo opposite 1 Safe Working Load specification allowing for a substantial safety margin Page 6 2 QD2300 5 AvantGuard Electric Bed User Manual Patient Helper Positioning Ad WARNING The patient helper in the patient transfer position is designed to help the patient lift some of his her weight so as to assist the nursing staff with their work This position is not designed to allow patients to transfer ihemselves alone Normal egress Patient aid transfer position position Tuck away position Use the blue knob marked TURN to adjust patient helper position To adjust patient helper position Turn the blue knob a quarter turn clockwise to unlock the patient helper Place the patient helper in the required position Turn the knob anticlockwise to lock in position Turn the patient helper slightly until it locks into place Pull the patient helper to ensure that the position is secure QD2300 5 AvantGuard Electric Bed User Manual Page6 3 Patient helper hand
30. could occur Pay close attention to the position of the cylinder holder particularly if it is under the head section or the siderail when setting the Reverse Trendelenburg position or when lowering the sleep surface Prevent any impact when moving a bed equipped with a cylinder holder to another room especially doorways Ifthe cylinder holder does not allow the bed to go through a doorway position the holder in front of the bed otherwise place it and the cylinder on the mattress remember to put the holder in its normal position after moving the bed Equipotential cable AD968A This cable is designed to connect a metallic accessible part of some medical intravascular or intracardiac equipment to the bed It consists of two POAG WB 6 DIN type connectors and a 2m long yellow and green cable Page 6 8 QD2300 5 AvantGuard Electric Bed User Manual Syringe driver holder AC963A Safe working load 15 kg 4A WARNING Do not position the accessory facing inwards particularly under the head section when it is raised so as to prevent any risk of the accessory obstructing the head section or siderail when being handled This accessory is designed to accept a syringe driver and is fitted at the head end of the bed in the sockets provided 1 The safe working load specifications allow for a substantial safety margin QD2300 5 AvantGuard Electric Bed User Man
31. e NEUTRAL position Ni SS Head Foot SS NOTE Incompatible with 125 mm diameter casters Before moving the bed sideways check that the brake and steer bar is in the NEUTRAL position Bed Connected to AC Power Brake not Applied Detection When the bed is plugged into AC power and the brakes are not set an alarm sounds until the brakes are set or AC power is removed Page 4 30 QD2300 5 AvantGuardO Electric bed User Manual Moving the bed AX WARNING Failure to perform any of the checks below could result in injury or equipment damage Before moving the bed perform the following checks e If there is a patient in the bed ensure that the siderails are raised and locked to help prevent the patient from falling Position the sleep surface so the footboard handles are at the most suitable height for transporting the bed approximately 2 Hi Low and with the foot section horizontal Disconnect the general power cable and the power cable of the electric accessories e g air mattress etc and hook them to the bed as described in paragraph Securing the power cable page 4 32 Ensure that the bed or accessories patient helper etc will not catch on doorways or other obstacles e g lights Place the control pendant on the inside of the head siderail to prevent any damage to the control pendant or cable e g catching on doorways etc Place the patient in a stable and co
32. e moved NEUTRAL position bar horizontal all four casters can turn and swivel The bed can be turned in any direction STEER position bar up Page 4 28 QD2300 5 AvantGuara Electric bed User Manual Using the bar in the steering position without 5 wheel basic version The casters turn and only the caster A or B foot end steering caster can be steered and does not swivel The bed can be moved in a straight line BN ES Head Foot es E with self steering 5th wheel NOTE When the bed is fitted with a self steering 5 wheel the steer position on the brake and steer bar is not available The 5 wheel automatically changes to the steering position when the bed is moving in a straight line forwards or backwards or sideways 90 to the left or right and is released the next time the bed is moved Incompatible with 125 mm diameter casters A Hea gt Foot NOTE Incompatible with 125 mm diameter casters QD2300 5 AvantGuard Electric bed User Manual Page 4 29 with controlled 5th wheel When the bed is fitted with a controlled 5th wheel the steer position on the brake and steer bar remains available When the brake and steer bar is in the steering position the 5 wheel automatically switches to the steering position as soon as the bed moves forwards or backwards The wheel is released when the brake and steer bar is returned to th
33. e various power driven features of the bed The pendant can be secured in the housings provided in the siderails See Positioning page 4 45 This mechanism allows the control pendant to be positioned as ergonomically as possible for the patient and the nursing staff For the functions refer to Electrical controls page 2 6 Control pendant for patients Control pendant for nursing staff I The control pendant can be placed on the right hand or left hand side of the bed See the position in Control Pendant page 4 44 QD2300 5 AvantGuardO Electric bed User Manual Page 4 11 Control pendant on a flexible arm Patient side The control unit on a flexible arm is equipped with a touchpad on both sides One side is intended for the patient and the other side for the nursing staff The arm can be positioned on the right hand or left hand side of the head section To move the arm from one side to the other see Control unit on a flexible arm page 4 43 For the functions refer to Electrical controls page 2 6 Bilateral HiLow Pedal Ad WARNING Ensure that no accessory or other device interferes with the use of the pedal Failure to do so could result in patient injury or equipment damage This pedal is located centrally under the lower bed frame on each side Nursing staff can use this pedal to adjust bed height and activate or deactivate the function management mode while keeping their hand
34. ears in order to ensure continuing operation in optimal condition QD2300 5 AvantGuard Electric Bed User Manual Page 5 9 NOTES Page 5 10 QD2300 5 AvantGuard Electric Bed User Manual Chapter 6 Accessories Accessories Ad CAUTION The accessories shown are not designed to be used all at the same time Some combinations can interfere with certain functions Combining accessories could result in equipment damage Some accessories are specific to certain versions and must not be installed on other versions It is advisable to ensure that the accessories features are mutually compatible Ad WARNING Personnel should take care that the weight and the loads on the accessories do not exceed 20kg Patient injury personal injury or equipment damage could result the patient helpers are not affected by this limit A LV pole B Patient helper C Oxygen cylinder holder D Accessory support QD2300 5 AvantGuard Electric Bed User Manual Page 6 1 Patient Helpers This accessory must only be fitted at the head of the bed Fixed patient helper ADO80B Safe Working Load 75 kg 165 35 1b 4 WARNING Do not position the patient helper at the outside of the bed See incorrect position shown below Patient injury or equipment damage could result The patient helper can be fitted into either of the two square sockets at the head of the bed Place the patient helper in the socket so that the p
35. ecommends that medical personnel determine the proper methods necessary to ensure a patient remains safely in bed without being constantly observed QD2300 5 AvantGuardO Electric bed User Manual Page4 1 TotalGuard integrated siderails The Electric bed AvantGuard fitted with TotalGuardTM siderails is able to receive a wide range of mattress widths See Mattress page 8 4 In order to achieve mattress siderail combinations offering optimal comfort and safety the bed can be configured with siderails in two retained and secure positions A WARNING Do not place accessories respiratory or other medical devices on the siderail in a manner that could interfere with the complete storage of the foot siderail and thus block access to the release mechanism for lowering the siderail when emergency access to the patient could be required The siderails must be handled according to the instructions in the user manual Failure to do so could result in injury The TotalGuardTM integrated siderails are part of the frame The siderails lift into the locked position and rotate from the head to the foot The width of the bed is reduced when the siderails are in the low position When fully raised and locked the siderails ensure patient protection and help to reduce the risk of falls Position 1 Siderail folded and in low position Position 2 Siderail folded and in high position Position 3 Siderail unfolded in high position
36. ectric Bed User Manual
37. ed and whether the patient should be monitored closely to ensure patient safety Medical staff should note the risks involved in the use of siderails of any model or type with particularly old frail restless disorientated or confused and obsessive patients Certain national health authorities have issued guidelines on how to reduce these hazards as indicated below It is recommended that patients with health or behavioural problems of this type be identified in each establishment or ward so that the safety measures most appropriate to their particular needs can be implemented see above Page 8 2 QD2300 5 AvantGuard Electric Bed User Manual One measure which has already proved effective is to draw up a protocol if such a protocol is not already in place specifying 1 Situations and conditions for siderail use and authorised mattress type Situations and conditions for patient immobilization 3 Patient monitoring procedures both for restrained and unrestrained patients and procedures for the monitoring of straps etc 4 Should it be necessary to restrain a patient using special equipment follow the manufacturer s instructions carefully Use of a mattress thicker than the recommended 175 mm may reduce the effectiveness of the siderails in preventing falls In such cases the patient must be monitored closely The recommendations below may contribute to patient safety Always keep the bed in its lowest Hi Low pos
38. emove and replace the wooden headboard or footboard The headboard is equipped with bars Wooden headboard Wooden footboard To position the endboard Hold the headboard or the footboard by the handle and orientate it as shown on the pictures above Place the studs B in the holes in the head or foot of the bed To remove an endboard Hold the headboard by the handle A with both hands and pull upwards Page 4 36 QD2300 5 AvantGuard Electric bed User Manual Sleep surface Ad WARNING Ensure that hard surfaces are properly positioned and secured after fitting Failure to do so could result in patient injury or equipment damage The sleep surface is composed of 4 sections with hard surfaces Three of them can be removed for easy cleaning The head section hard surface is fixed To remove the thigh and foot hard surfaces simply lift them up To raise the central hard surface first fully raise the head section See Head section control page 4 21 Then raise the central hard surface by pulling on the bars and turning Then slide towards the rear Sections are positioned using the handles Ensure that the smooth part is placed downwards and the raised lip A upwards Ensure that there are spaces B as indicated below Restraining strap handles A WARNING Do not attach the restraining straps to any part of the bed particularly the siderails other than those provided for this p
39. en fitting the accessory Please refer to with controlled 5th wheel page 4 30 for usage instructions QD2300 5 AvantGuard Electric Bed User Manual Page 6 11 Accessory support bar AD126A Ad WARNING The accessory must be fitted by an authorized technician Failure to do so could result in patient injury or equipment damage Please refer to the fitting instructions provided with the accessory when fitting the accessory For usage refer to Accessory support bar page 4 46 Medical device support rail AD127A Ad WARNING The accessory must be fitted by an authorized technician Failure to do so could result in patient injury or equipment damage Please refer to the fitting instructions provided with the accessory when fitting the accessory For usage refer to Medical device support rail page 4 47 Page 6 12 QD2300 5 AvantGuard Electric Bed User Manual Bilateral HiLow pedal AD171A Ad WARNING The accessory must be fitted by an authorized technician Failure to do so could result in patient injury or equipment damage Please refer to the fitting instructions provided with the accessory when fitting the accessory For usage refer to Bilateral HiLow pedal page 4 17 Enable control pedal AD179A Ad WARNING The accessory must be fitted by an authorized technician Failure to do so could result in patient injury or equipment damage
40. er cable is an electric shock hazard Prior to transport properly stow the power cord to prevent tripping Take care to prevent damage to the power cable An electric shock hazard exists Page 4 32 QD2300 5 AvantGuardO Electric bed User Manual Equipotential terminal W Y SHOCK HAZARD Failure to connect the equipotential cable may result in corporal injury When direct intravascular or intracardiac connections are in use the electric potentials of all the unprotected metal parts need to be equalized The bed must be connected to the electrical installation To equalize potentials if a grounded power connection is unavailable connect the equipotential cable AC968A to the connection terminal on the bed and the device Handling the headboard and footboard Ad WARNING The headboard bars are not intended to receive accessories accessory support device or any means of immobilizing the patient e g straps Failure to do so could result in patient injury or equipment damage Polypropylene headboards and footboards A WARNING Do not invert the headboard and footboard Failure to do so could result in patient injury or equipment damage The headboard and footboard are provided with a label which helps to differentiate the headboard from the footboard see photos on next page QD2300 5 AvantGuard Electric bed User Manual Page 4 33 Polypropylene headboard Polypropylene footboard Ad
41. esence of flammable gas or vapours Use at unauthorized temperatures not between 0 C and 40 C Any use not complying with the instructions for use described in this manual Any other use which does not comply with normal use of a hospital bed or its stated purpose De commissioning The bed and its accessories should be cleaned and disinfected before de commissioning y De commissioned equipment materials plastics electrical we components etc must be recycled in accordance with local recycling regulations Please previously check and comply with the local environmental policy Directive 2002 95 CEE As regards the battery Never dispose of the lead acid dry fit battery which contains substances and dangerous metals for the environment and the 2 health Life expectancy of components The bed and its listed elements below were designed to be used under normal conditions according to the instructions for use and maintenance with an expected life of approximately Element Expected life Electric actuators 5 years Gas springs 5 years Power supply 10 years Frame 10 years NOTE It is the responsibility of the facility to implement a preventive maintenance program for the bed s functions under its conditions of use Page 8 8 QD2300 5 AvantGuard Electric Bed User Manual Chapter 9 Specifications and warranty Specifications Hill Rom has an ongoing continuous impro
42. ices or is not susceptible to interference when combined with other medical devices that also comply with the electromagnetic standards in force Some devices particularly older ones that do not comply with the electromagnetic compatibility standards may however undergo interference or may themselves interfere with the working of this product The users of such devices are responsible for ensuring that any malfunctions will not endanger the patient or any other person Ensure that the power cord is unplugged and hooked to the bed before moving the bed See Securing the power cable page 4 32 Only duly qualified and authorized staff should carry out electrical maintenance Never clean or service the bed without unplugging it from the mains power supply and disconnecting the battery The battery backup must never be left in direct contact with fire placed in liquid or discarded in a refuse bin In the event of the battery being damaged see De commissioning page 8 8 Use only nasal tubes and oxygen masks For reasons of safety masks and tubes should always be kept at a higher level than the sleep surface Always lock out the Hi Low function before any operations other than cleaning or maintenance Page 8 6 QD2300 5 AvantGuard Electric Bed User Manual Abnormal use Ad CAUTION Abnormal use may result in damage to the bed and injury to patients or staff Examples of abnormal use Use of the bed for any pu
43. in the inability to operate the bed when power is unavailable If the indicator C is flashing it indicates a low battery and is charging If the charge indicator B is on and not flashing then the battery is fully charged When the bed is disconnected from the mains power supply or when the battery is completely dead this indicator light goes off QD2300 5 AvantGuardO Electric bed User Manual Page 4 41 MobiBar egress handle A MobiBar egress handle is located on each side of the bed It enables mobile patients to get in and out of the bed with greater ease and in safety 4 WARNING Before use it is necessary to store the TotalGuard foot siderail support under the sleep surface See Storing the foot siderails Position 2 page 4 5 Never put or leave the MobiBar egress handle in the raised position when the TotalGuard foot siderail is unfolded and or locked Fingers or body members may become trapped Usage Grip the egress bar by the handle A Rotate the egress bar toward the head of bed until a click is heard Ensure the locking mechanism is secure by pulling on the handle Page4 42 QD2300 5 AvantGuard Electric bed User Manual Storaqe Grip the egress bar by handle A with one hand Pull by the low part B the egress handle 1 outwards with the other hand While continuing to pull rotate the egress handle 2 toward the foot of the bed and u
44. individual risk assessments including but not limited to Caught Hazard Potential falls from the bed Confused patients Patients with learning difficulties Small children Persons without the mental capacity to recognize unsafe actions Unauthorized persons All persons authorized to use the bed s functions must be capable of doing so in a safe and controlled manner In case of doubt the bed s functions must be locked Bed model and country of use Certain bed features may be available or not depending on the destination country These features are identified with an asterisk To identify your bed model and serial number HRP000000 refer to the identification label See Overview page 2 8 Your bed LI158Bx is composed of a chassis bed frame identified CS158Bx and two endboards QD2300 5 AvantGuard Electric Bed User Manual Page 1 3 NOTES Page 1 4 QD2300 5 AvantGuard Electric Bed User Manual Chapter 2 Introduction overview Introduction Function Symbols Manual Controls The following labels located next to the relevant control identify manual operations Head section CPR Ce CPER sa Sen X Adjustable foot section A 4 x Angle Indicators Trendelenburg Reverse Trendelenburg ecd NOTE These indicators are not measuring devices QD2300 5 AvantGuardO Electric Bed User Manual Page2 1 Warning and Caution Labels Locking Mechanism
45. ing the foot siderails Position 2 4A WARNING When storing the foot siderail make sure that no objects or limbs are in the way Failure to do so could result in patient injury or equipment damage To store the foot section of the siderail With one hand A grip the foot siderail by the handles With the other hand press the release button B Raise the siderail and rotate it towards the head end Position the foot siderail in the support C provided for storage at the head end QD2300 5 AvantGuardO Electric bed User Manual Page4 5 Foot Siderail Support The foot siderail supports on both sides of the bed can be folded away thus enabling the caregivers to move freely when transferring the patient to another platform To fold away a siderail support Make sure that the foot siderail is folded Hold the foot siderail support A with one hand With the other hand pull the release pin B Release the handle and swing the support beneath the sleep surface To raise a siderail support Raise the foot siderail support until you hear a click Verify the siderail support is locked by pulling on the siderail support Page4 6 QD2300 5 AvantGuardO Electric bed User Manual Long metal siderails Ad WARNING Do not place accessories respiratory or other medical devices on the siderail in a manner that could interfere with the siderail when emergency access to the patient could be req
46. ion record should be kept for each bed mentioning Date month year ward and room number bed reference number Cleaning frequency materials and products used Removal of the Foot TotalGuard Siderail NOTE The foot part of the siderail is removable in order to permit thorough disinfection NOTE The foot siderail should only be dismantled when the siderail is in the folded position see Storing the foot siderails Position 2 page 4 5 Grip the foot siderail as follows With one hand on the positioning lug at the head end A and the other near the button B as shown on the photo below Pushon the unlocking button and pull the foot siderail You can then proceed to clean all surfaces of the head and foot siderails QD2300 5 AvantGuard Electric Bed User Manual Page 5 5 Foot Siderail Assembly Place the foot end of the foot siderail on the positioning lug of the head siderail A Align the foot siderail in front of the head siderail socket B and push until an audible click is heard Verify that the foot siderail is well seated by testing its operation see Unfolding the foot siderails position 3 page 4 4 Removal of the interior siderail cover Pull 1 outwards on the siderail cover and rotate it Pull 2 the siderail cover upwards The siderail and siderail cover can now be cleaned Page 5 6 QD2300 5 AvantGuard Electric Bed User Manual Installation of
47. ioning can be activated using the control pendant or the control unit on a flexible arm The automatic contour feature raises the head section and the adjustable thigh section simultaneously and helps to prevent the patient from sliding down in the bed The automatic contour feature is only available when both the head section and thigh section functions are enabled NOTE When the head section is locked out the adjustable thigh section can still be activated by the control pendant or the control unit on a flexible arm Thigh Section Electric thigh section control Thigh section elevation can be adjusted by using the control pendant or the control unit on a flexible arm Raise thigh section Lower thigh section When the thigh section is raised the foot section is inclined at an angle of approximately 14 from the sleep surface See Foot section page 4 23 Page4 22 QD2300 5 AvantGuard Electric bed User Manual Foot section Electric foot section The foot section of the bed can be electrically raised by using the control pendant or the control unit on a flexible arm NOTE The angular range that the foot section can be adjusted to depends on the angle to which the thigh section is adjusted To raise the foot section Press the raise foot section button A until the required angle is reached then release To lower the foot section Press the lower foot section button B
48. ition when the patient is left unattended tis not possible to ensure the compliance of all mattresses with our recommendations given the many different types of mattresses available For safety reasons we recommend that users pay particular attention to mattress dimensions with regard to siderail height Mattresses are not all interchangeable Hill Rom shall in no way be held liable for problems arising from the use of siderails or mattresses produced by other manufacturers which do not comply with the recommendations set out in this manual Implementing the recommendations listed above should help to reduce accident hazards QD2300 5 AvantGuard Electric Bed User Manual Page 8 3 Mattress Only mattresses recommended by Hill Rom should be used In order to reduce the risk of the mattress sliding it is recommended that the mattress be placed between the raised edges and that it is laid correctly on the sleep surface Should you wish to use a mattress other than those recommended please ensure that it is compatible with the Hill Rom bed model and that it will not have any adverse effect on performance quality or safety The beds are designed for use with standard size mattresses length 195 200 cm width 83 90 cm and thickness 175 mm suitable for the sleep surface dimensions Ad CAUTION If the bed is fitted with an electrically powered air mattress the power cord must be routed so as to prevent it from bei
49. le Ad WARNING The patient helper handle must be positioned between lugs A and B to avoid any danger of slippage Failure to do so could result in patient injury or equipment damage The patient handle on the patient helper can be adjusted according to the patient s preference To adjust the height of the handle push on the locking mechanism button adjust the height and release the button Check the locking mechanism by pulling on the patient handle Place the patient handle on the patient helper arm when not in use in order eliminate any obstruction If the bed is equipped with both an adjustable patient helper AD081C and an I V Pole AD0824A do not use the patient helper tuck away position as this may interfere with the I V pole Page 6 4 QD2300 5 AvantGuard Electric Bed User Manual Telescopic I V pole Ad CAUTION Ensure that the I V pole is positioned facing towards the bed and not outwards as shown in the following illustrations EO O p Ee B gt d L p ye ae Safe working load Refer to the value indicated on the I V pole Using the I V pole AD082A To raise the I V pole qa Hold the square part of the pole with one hand and raise the upper part to the desired height To lower the I V pole Hold the upper part of the pole firmly and lift slightly while pressing downward on the plastic sleeve with two fingers of the
50. mains power supply for the bed must comply with relevant standards NF C 15 100 and NF C 15 211 France International Electrotechnical Commission IEC 364 for other locations Check that the bed s power requirements on the identification label See Overview page 2 8 correspond to the power supply voltage of the hospital The power supply should be equipped with a maximum 30 mA earth leakage circuit breaker in compliance with IEC 364 5 53 Page 3 2 QD2300 5 AvantGuard Electric Bed User Manual Chapter 4 Instructions for use Use Siderails The Electric bed AvantGuard can be fitted with two types of siderail Integrated siderails TotalGuardTM Long detachable metal siderails Ad WARNING Always ensure that there are no obstacles before raising or lowering a siderail e g person s limb objects accessories They are not designed to restrain or immobilize the patient No containment devices must be fastened to the siderails e g straps Failure to do so could result in patient injury or equipment damage A WARNING Evaluate patients for entrapment risk according to protocol and monitor patients appropriately Ensure that all siderails are fully latched when in the raised position Failure to do either of these could result in serious injury or death NOTE Siderails are intended to be a reminder to the patient of the unit s edges not a patient restraining device When appropriate Hill Rom r
51. mbols eese eh 1 2 Intended Use nn fitch 4 k in 2di r b vil al E E RH AEN 1 3 Before placing the patient on the bed 1 3 Bed model and country of use 0000000 1 3 Chapter 2 Introduction overview Introduction ae E er UR e egre RE RC RUR 2 1 Function Symbols KK KK KK KK KK KK KK KK KK KK KK 2 1 OVGryIeW iseettepsputerq eere pt ED QI CR WAV EI Seg 2 8 Standard Features na Hak G wae n yey 2 AEEA 2 9 Equipment varies depending on bed model 2 9 ACCeSSOLIeS iss see oka Ru eR c RR Rc ed ade Eton 2 10 Chapter 3 Installing the bed Installing the D d lt ya dle k n a Wa K n KA Sea eee 3 1 First Steps sis n SORE A AE DE os Ede pet oats are eb qe 3 1 Connection to the Mains Power Supply 3 2 Chapter 4 Instructions for use lu E 4 1 IDET AUS ryrie 15 oe Mame Ue E pH CI Eta ed 4 1 Electrical Functions 0000 cee eee eee 4 11 Electrical function management 2000 5 4 13 Sleep Surface yc ola is RR ee UR da k c E 4 16 Reference mark for positioning the patient 4 20 H ad section esser CLP N eS 4 21 Thigh Section sooo vba pb soba ebay 4 22 Foot section csse bert Ve e ever Eb e4 ES 4 23 Automatic EasyChair KK KK KK KK KK KK KK K KK 4 25 Emergency functions AK KK KK KK KK KK KK KK 4 26 Brake and steer system 4 28 Securing the power cable
52. mfortable position do not put the bed in the chair position or with a fully raised head section A CAUTION Never try to move the bed by pulling on the power cable or you may damage it E SHOCK HAZARD A damaged power cable is an electric shock hazard Ad WARNING Applicable for beds manufactured with variable width siderails and headboard bars 4A WARNING The bed must be moved while in transport position by 2 people one at each end in order to have always one person to action the brake bar when moving the bed on a slope with a foot end steer caster or when moving the bed with a heavy load heavy patient accessories fitted etc QD2300 5 AvantGuardO Electric bed User Manual Page 4 31 Moving the bed Grip the headboard or frame with both hands Raise the brake and steer bar to the NEUTRAL position to unlock the brakes Push the bed steering with the headboard For easy transportation in a straight line Push the bed using the end board opposite the steering wheel See Using the brake and steer bar page 4 28 After having moved the bed for a short distance to align the casters raise the brake and steer bar to the STEER position Securing the power cable A CAUTION Do not store the power cable in the holes in the headboard Doing so may result in entanglement problems with the headboard while removing the headboard during emergency CPR SHOCK HAZARD A damaged pow
53. ncy Trendelenburg A CAUTION The patient s safety may be jeopardised in the absence of a Reverse Trendelenburg feature in cases of haemodynamic shock or severe breathing difficulties The patient must never be left unattended while the bed is in Trendelenburg Failure to observe this precaution could result in patient injury or equipment damage E QD2300 5 AvantGuard Electric Bed User Manual Page8 1 Trendelenburg Reverse Trendelenburg and emergency Trendelenburg required in intensive care units must only be operated under the supervision of or by trained nursing staff Ad CAUTION Sufficiently qualified nursing staff determine the usage condition suitable for this function and degree of supervision to ensure that the patient uses the bed safely A WARNING Before setting in the Shock position it is imperative to lower the siderails Integral Siderails The siderails should be raised and locked when a patient is left unattended The siderails are designed to help reduce the risk of patients falling out of bed accidentally They are not designed to restrain or immobilize the patient Restraining straps or other devices must not be fastened to the half length siderails e g straps In the case of patients suffering from particular behavioral difficulties agitation mental confusion loss of sense of direction weakness etc properly trained medical staff should ascertain how the siderails should be us
54. nder the sleep surface then release Control unit on a flexible arm A WARNING When the bed features an I V pole the flexible arm must be fitted on the opposite side of the bed to prevent any risk of catching it when the head section is raised Failure to do so could result in patient injury or equipment damage This unit can be placed to the left or right of the head section as required QD2300 5 AvantGuard Electric bed User Manual Page 4 43 Change of position Ad WARNING Two people are required for this operation and the bed must not be occupied Failure to do so could result in patient injury or equipment damage To change the position of the flexible arm Raise the head section to its maximum height As one person holds the arm the other person turns the beige knob with one hand while holding the captive nut with the other hand Set the arm in the other position Insert the screw in the oblong orifice and fully tighten the beige knob Check the positioning by pulling on the arm Control Pendant Installation Fit the control pendant in the open part of the TotalGuardTM siderail or between the two upper bars of the metal siderail by inserting the top edge first 1 Turn 2 the control pendant until you hear a click Page 4 44 QD2300 5 AvantGuard Electric bed User Manual Positioning A CAUTION Make sure that the control pendant is inside the
55. ng cut by the moving parts of the bed Failure to observe this precaution could result in patient injury or equipment damage If the mattress power cord is unplugged it is advisable to store it on one of the headboard supports see Securing the power cable page 4 32 or on the support provided by the mattress supplier Headboard A WARNING The headboard bars are not intended to receive accessories accessory support device or any means of immobilization of the patient e g straps A WARNING The headboard bars are not intended to be used as handles during transfer of the bed Cleaning and recommended cleaning fluids Always disconnect the bed from the mains power supply before cleaning see General Advice page 5 2 Only use recommended cleaning fluids and products see Recommended Materials and Products page 5 3 Page 8 4 QD2300 5 AvantGuard Electric Bed User Manual Electrical function management The electrical function management controls prevent any unintended bed movements that might cause injury to the patient for instance when under traction etc It is highly recommended that functional lock out should be used whenever a patient is undergoing examination or treatment or when the bed is being serviced or moved Functions should also be locked out when the patient is left unattended and if the nursing staff believe that the patient is not capable of operating the controls independently with s
56. ng metal siderail Linen holder label O Never use the linen holder as a seat or as a foot step and never exceed the maximum load that can be placed on the linen holder Headboard and metal sierails identification label gt This label indicates to place the headboard on the head end on the bed This type of headboard must be only used on beds with long metal siderails or beds without siderails TotalGuardTM headboard and metal siderails identification label This label indicates to place the headboard on the head end on the bed This type of headboard must be only used on beds fitted with TotalGuardTM siderails Page 2 4 QD2300 5 AvantGuard Electric Bed User Manual Plastic footboard identification label This label indicates to place the footboard at the foot end of the bed QD2300 5 AvantGuard Electric Bed User Manual Page2 5 Electrical controls Control pendant without EasyChair I G C A M L Functions available to the patient and caregiver A Head section raise F Foot section lower B Head section lower G Hilow raise C Thigh section raise H Hilow lower D Thigh section lower I Bed non low position indicator E Foot section raise Functions available only to the caregiver J EasyChair position N Trendelenburg K Return to flat sleep surface O Reverse Trendelenburg L Battery
57. ontrol pedal Casters 125 mm diameter single band 150 mm diameter single band 150 mm diameter double band 150 mm diameter antistatic double band LI a0 OOOOOOOOOOO OOOO 150 mm diameter antistatic single band Directional caster at foot end of bed LI QD2300 5 AvantGuardO Electric Bed User Manual Page2 9 Bed connected to AC power brake not applied detection L Self steering 5th wheel L Controlled 5th wheel LI MobiBar egress handle L Integral bed extension at foot end of bed LI Integrated linen holder LI Accessory support bar 2 hooks LI Accessory support bar 6 hooks L Multiple bag support LI Headboard and footboard Standard polypropylene headboard and footboard Standard polypropylene headboard and LI lockable footboard Medispace headboard and footboard Sequoia headboard and footboard LI Medic hotel headboard and footboard Accessories AC908A AC932A AC938A AC961A AD016A AC991A AC959A AC962A AD101A AD102A AC963A AC968A ADO080B AD081C AD082A AD165A AC953A 2 receptacle bottle holder 3P 11 pivoting stainless steel bottle holder 3P 21 pivoting stainless steel bottle holder 3 litre bottle holder for frame Semi spherical drainage holder Triangular section drainage holder Oxygen cylinder holder 3 litre bottle holder for foot end Oxygen cylinder holder Oxygen cylinder holder Syringe driver holder Equipotential cable Chrome plated patient helper Chrome
58. out the automatic contour feature See Automatic Contour page 4 22 NOTE Locking out the head section does not lock out the thigh section adjustment of the automatic contour function 4A WARNING When the patient is restrained by the straps the electric functions must be locked out Failure to do so could result in patient injury or equipment damage QD2300 5 AvantGuardO Electric bed User Manual Page4 15 Sleep Surface Power driven HiLow Sleep surface height can be adjusted using the control pendant the bilateral HiLow pedal or the control unit on a flexible arm Ad WARNING Before using this function check that no obstacles e g objects accessories power cables or persons especially children are under the sleep surface Check that patient s limbs are within the sleep surface Failure to do so could result in patient injury or equipment damage A CAUTION Ensure that the bed and accessories patient helper V pole etc cannot strike any fittings light fittings headwalls etc or hospital furniture chair bedside cabinet etc Failure to do so could result in equipment damage NOTE Before using the HiLow function check that it is enabled See Electrical function management page 4 13 Control pendant Raise Lower To adjust the height of the sleep surface Press the arrow of the symbol for the movement you require Release when the required height is reached
59. plated adjustable patient helper Stainless steel I V pole I V pole Chrome plated I V hooks on patient helper Page 2 10 QD2300 5 AvantGuard Electric Bed User Manual AD128A Monitor stand AC923A Label holder AD126A Accessory support bar AD127A Medical device support rail AD069A Bultex amp comfort mattress AD162A Extension cushion for Bultex comfort mattress AD066A Cliniplot III mattress AD076A Extension cushion for Cliniplot III mattress AD085A Primo M dynamic low pressure mattress system ADI117A01 Mattress Clinisert 2 High resilience insert sewn and taped cover AD118A01 Mattress Clinisert 2 High resilience insert welded cover AD119A01 Mattress Clinisert 2 Visco elastic insert sewn and taped cover AD120A01 Mattress Clinisert 2 Visco elastic insert welded cover AD164A Extension cushion for Clinisert 2 AD140A Duo 2 Multi Mode Mattress System AD177A MobiBarQ egress handle AD135A Self steering 5th wheel AD180A Controlled 5th wheel ADI71A Bilateral HiLow pedal AD139A Linen holder AD128A Monitor stand AD142A Removable frame AD166A Control unit on flexible arm without EasyChair AD174A Control unit on flexible arm with EasyChair AD167A Control pendant for patient without EasyChair AD168A Control pendant for nursing staff without EasyChair AD175A Control pendant for patient with EasyChair AD176A Control pendant for nursing staff with EasyChair AD178A Long metal sider
60. r Manual CPR Ad WARNING Never allow a non qualified person to operate this function and check that no obstacles e g objects accessories power cables or persons are under the head section When activated the CPR release resuscitation heart massage etc uncouples the head section actuator to allow the head section to lower to horizontal from any position The CPR release function is gas assisted to cushion the movement and can be used when electric power is not available It is operated by a handle located centrally and bilaterally under the sleep surface Returning the head section to the flat position Pullthe yellow CPR handle out hold and push the head section down with the other hand Letthe head section come to rest or steady and assist the head section to the flat position Release the handle when the head section is flat The head section actuator is automatically re enabled after the yellow CPR handle is released QD2300 5 AvantGuardO Electric bed User Manual Page4 27 Brake and steer system Using the brake and steer bar A WARNING Always put on the brakes when the bed is occupied except during patient transport To make sure the bed will not move push and pull on the bed to check it after the brakes are engaged The brake and steer bar located at the foot of the bed on the chassis cover controls all four casters BRAKE position bar down the bed cannot b
61. rd Electric bed User Manual Trendelenburg Reverse Trendelenburg AX WARNING Before enabling this function check that the frame extension is securely locked in one of the notches and that no obstacles e g e g objects accessories power cables tubes or persons especially children are under the sleep surface Check that patient s limbs are within the sleep surface Failure to do so could result in patient injury or equipment damage 4A WARNING Never leave the patient unattended in the Trendelenburg Reverse Trendelenburg position See Trendelenburg Reverse Trendelenburg and Emergency Trendelenburg page 8 1 NOTE The Trendelenburg Reverse Trendelenburg is not an emergency function and is only available for the nursing staff via the electrical function management See Electrical function management page 4 13 The sleep surface may be inclined in two ways in Trendelenburg head end in low position or Reverse Trendelenburg foot end in low position The maximum angle for the Trendelenburg Reverse Trendelenburg is available at all heights of the sleep surface The angle is shown on the indicator located on the foot siderail support To tilt the sleep surface Activate the function management See Activating deactivating function management page 4 14 Press the button corresponding to the function required on the control pendant or control unit on a flexible arm Release the button when the
62. rpose other than for general or intensive care Use of the bed in a hyperbaric chamber Use of bed functions accessories or bed movement by persons who do not have the ability to operate the bed safely Operation of electrical functions by several persons at the same time Placing objects or equipment on the chassis or using it to support a person e Use of the bed with a loads over 185 Kg Safe Working Load Connection to a non standard power supply Connection of other electrical appliances to the bed Use of accessories and equipment other than those specified by the manufacturer Pulling on the power cord to move the bed Moving the bed when the 5 steering wheel with controlled operation is active Washing with excessive water or high pressure jet or in a tunnel wash Use outdoors or in a vehicle Climatic constraints operation storage other than those specified by the manufacturer Use of the bed in an atmosphere presenting a risk of explosion Moving the bed over soft ground or over inappropriate surfaces Moving the bed along slopes of over 10 with or without a patient Actuator or column overload see intermittent operation in paragraph Technical specifications page 9 1 l QD2300 5 AvantGuard Electric Bed User Manual Page 8 7 Use of oxygen tent type respiration devices or devices that extend below the sleep surface Use of the bed in the pr
63. rs estive etuer ate ee fetes Ss 6 2 Telescopic LV pole ss lk 0 00 cee ee eee eee 6 5 Monitor Stand AD128A AV kK KK KK KK KK KK KK K KI KK IK 6 6 Oxygen Cylinder Holder AC959A ADIOIA AD102A 6 7 Equipotential cable AD968A LR KK KK KS 6 8 Syringe driver holder AC963A KK RR KK KK 6 9 MobiBar egress handle AD177A KK 6 10 Control unit on a flexible arm 22 eee eee ee 6 10 Self steering Sth wheel AD135A SK KK 6 11 Controlled 5th wheel AD180A 00055 6 11 Accessory support bar AD126A A KK 6 12 Medical device support rail AD127A 6 12 Bilateral HiLow pedal AD171A 6 13 Enable control pedal AD179A SK KK KK 6 13 Page ii AvantGuard Electric Bed User Manual QD2300 5 Long metal siderails AD178A LV KK 6 14 MA ltTeSS DD DD RR DJ io Bae ost 6 14 Accessory holder rasani serere etes 6 15 Chapter 7 Shipment storage and usage Transport Stordge exea bee ele ges Be 7 1 lU c EE 7 2 Chapter 8 Safety tips and precautions Safety TIPS weit weed EU p eb HE pe EE eed 8 1 Brake and steet ce uree tane 43 2 4200 PEERS ER eg 8 1 Bed Position is 4 454 m RR Rt erp ERR 8 1 Trendelenburg Reverse Trendelenburg and Emergency Trendelenburg 0 000005 8 1 Integral Siderails sk si l o celeres 8 2 Mattress s ra eR nd We LR Sek aa a X arada 8 4 Headboard s og cx LEE DER 8 4 Cleaning and recommended cleaning fl
64. s Several single use tissues or recyclable textile wipers One pair of household gloves Detergent disinfectant solution diluted according to hospital guidelines and taking into account the recommendations given above or a disinfecting spray e Use a standard product that complies with AFNOR standards NF T 72 101 bactericide including TB fungi and viruses including HIV 1 and HBV Recommended Cleaning and Disinfection Method Always wipe downward working from the cleanest to the dirtiest areas Do not scrape surfaces Keep wipes damp wet as many times as needed and do not wring out too much water QD2300 5 AvantGuard Electric Bed User Manual Page 5 3 Let product dry according to disinfectant manufacturer s recommendations to ensure maximum efficiency Rinse if necessary follow the recommendations of the disinfectant supplier Change wipes when cleaning the least contaminated areas to areas of medium or to highly contaminated areas Change wipes when cleaning another bed Always dry the bed thoroughly after it has been cleaned Recommended Cleaning and Disinfection E Clean and disinfect every day H E Clean and disinfect after patient departure Clean and disinfect thoroughly after the w H departure of the infected patient or according to the facility s disinfection protocol Page 5 4 QD2300 5 AvantGuard Electric Bed User Manual Disinfection Record A disinfect
65. s clean and free to deal with the patient Page4 12 QD2300 5 AvantGuard Electric bed User Manual Enable key pedal Ad WARNING Ensure that no accessory or other device interferes with the use of the pedal Failure to do so could result in patient injury or equipment damage This pedal is located centrally under the lower bed frame on each side Nursing staff can use this pedal to activate or deactivate the function management mode while keeping their hands clean and free Electrical function management 4 amp WARNING See Safety Tips page 8 1 The electrical function management nursing mode selectively locks out or releases the power driven functions of the bed according to the nurse s patient management needs The functions to be locked out or released are selected on the control pendant or the control unit on the flexible arm after activation of the function management QD2300 5 AvantGuard Electric bed User Manual Page 4 13 Activating deactivating function management Press manually the enable control 1 on the lateral caregiver unit or with the top of the foot actuate control 2 or 3 9 The control pendant or control unit on a flexible arm indicator is alight the electrical function management is active Press control 1 or 2 or 3 to deactivate the function management when the functions have been selected NOTE The Trendelenburg Reverse Trendelenburg
66. same hand Lower the pole to the required height Release the sleeve 1 The safe working load specifications allow for a substantial safety margin QD2300 5 AvantGuard Electric Bed User Manual Page 6 5 Using the I V pole AD165A To raise or lower the I V pole Loosen the threaded knob A while holding the lower pole to prevent it from lifting out of the accessory socket Firmly grip the upper pole with the other hand just below the plastic collar B Push the plastic collar up with the thumb Lower the pole to the required height Tighten the threaded knob A To swivel the I V pole Loosen the threaded knob A Adjust the upper pole to the desired angle while respecting the safety recommendations Tighten the threaded knob A Monitor Stand AD128A Safe working load 15 kg The monitor stand fits into the sockets at the foot of the bed 1 A WARNING When fitting the monitor ensure that the folded table is located on the outer edge of the bed The table must be folded away when moving the bed If the bed is in Trendelenburg or Reverse Trendelenburg any device that is used must be secured to the monitor stand Failure to do so could result in patient injury or equipment damage NOTE Introduce both ends simultaneously to avoid the frame getting jammed in the sockets 1 The safe working load specifications allow for a substantial safety margin
67. switch activation P Function management indicator M Power indicator Page2 6 QD2300 5 AvantGuard Electric Bed User Manual Bilateral HiLow Pedal Lower Raise Enable control under the pedal reserved for nursing staff Enable control pedal IH NHILLENSRAND INDUSTRY T Enable control under the pedal reserved for nursing staff Lateral caregiver unit without emergency Trendelenburg Battery indicator Electrical function lockout indicator Enable control reserved for nursing Thigh Head Hilow staff Section section Lateral caregiver unit with emergency Trendelenburg Shock position Battery indicator Electrical function lockout indicator Enable control reserved for nursing Thigh Head Hilow staff Section section Power supply Battery This label confirms that the bed s operational g Ku functions remain available in the event of a power outage No battery OA QD2300 5 AvantGuard Electric Bed User Manual Page 2 7 Overview Control Unit on a Reference mark for Control Head section Flexible Arm positioning the Pendant 1 ok angle indicator patient Egress handle Vertical removable plastic footboard Removable plastic headboard TotalGuard integral siderail controls Integral bed 150 mm diameter extension single band casters Accessory support bar Head section CPR Lateral caregiver unit Hilow ped
68. tions that may affect patient or user safety Disregarding a warning could result in patient or user injury A CAUTION points out special procedures or precautions that personnel must follow to avoid equipment damage The symbol below highlights a CAUGHT HAZARD WARNING Caught Hazard Warning P The symbol below highlights a CHEMICAL HAZARD WARNING Chemical Hazard Warning ee The symbol below highlights a ELECTRIC SHOCK HAZARD Electric Shock Hazard QD2300 5 AvantGuard Electric Bed User Manual Page 1 1 General Symbols Attention read the safety instructions carefully and refer to the user manual AN DO NOT BIN follow the local recycling regulations be A Recyclable Material e Safety Earth Equipotential terminal v Class II Device r Type B Equipment e Direct Current Alternating Current amd Page 1 2 QD2300 5 AvantGuard Electric Bed User Manual Intended Use The AvantGuard line of hospital beds includes acute care beds Trendelenburg with battery backup is a mandatory requirement for acute care beds and general purpose variable height hospital beds for general care for use in post operative care and general medicine wards They are designed with the needs of the whole medical team in mind and facilitate the use of monitoring equipment and the transfer of patients to examination wards Before placing the patient on the bed Carry out
69. ual Page6 9 MobiBar egress handle AD177A A WARNING This accessory must be fitted by an authorized technician Failure to do so could result in patient injury or equipment damage fl Please refer to the fitting instructions provided with the accessory when fitting the accessory For usage refer to MobiBar egress handle page 4 42 Control unit on a flexible arm 4 WARNING This accessory must be fitted by an authorized technician Failure to do so could result in patient injury or material damage vi i d gw Please refer to the fitting instructions provided with the accessory when fitting the accessory Please refer to Control unit on a flexible arm page 4 43 for usage instructions Page 6 10 QD2300 5 AvantGuard Electric Bed User Manual Self steering 5th Wheel AD135A Ad WARNING This accessory must be fitted by an authorized technician Failure to do so could result in patient injury or equipment damage Please refer to the fitting instructions provided with the accessory when fitting the accessory Please refer to with self steering 5th wheel page 4 29 for usage 9 instructions Controlled 5th wheel AD180A Ad WARNING This accessory must be fitted by an authorized technician Failure to do so could result in patient injury or equipment damage Please refer to the fitting instructions provided with the accessory wh
70. uids 8 4 Electrical function management lssessess 8 5 Parts and accessories W eee KK KK KK KK KK KK KK KK 8 5 Patient helpers 23 lt a sa ee eG RR av e s CER 8 5 Electrical safety precautions esee 8 5 Abnormal use 1x et RU PA OAR ER A Eee 8 7 De commissioning J kk KK KK KK KK KK KK KK KK KK KK KK KK 8 8 Life expectancy of components 2 0000 8 8 Chapter 9 Specifications and warranty Specifications scooter a ew eee Weel eas 9 1 Technical specifications leleeeeeeeeeeen 9 1 Dimensions ei oU SE se yane E a aan n REN 9 2 Specifications i eya b na ROLE IS bk eee ed 9 3 Warranty and after sales service conditions 9 4 Compliance eR RERUM aie u hun k be Te peed Gees 9 4 AvantGuard Electric Bed User Manual QD2300 5 Page iii NOTES Page iv AvantGuard Electric Bed User Manual QD2300 5 Chapter 1 Symbols destination Symbol Definition This manual contains different typefaces and icons designed to improve readability and increase understanding of its content Note the following examples Standard text used for regular information Boldface text emphasizes a word or phrase NOTE sets apart special information or important instruction clarification The symbol below highlights a paragraph WARNING or CAUTION Warning caution A A WARNING identifies situations or ac
71. uired The siderails must be handled according to the instructions in the user manual Failure to do so could result in injury The metal siderails can be integrated in the frame and detached Refer to the assembly instructions enclosed with the accessory for installation The siderails are unfolded by raising them on the side of the bed They are equipped with a double lockout system performing two functions When fully raised and locked the siderails ensure patient protection and help to reduce the risk of falls Position 1 Siderail in low position Position 2 Siderail in high position QD2300 5 AvantGuard Electric bed User Manual Page4 7 Raising the long metal siderails position 2 To raise a long metal siderail Grip the upper bar and pull upwards until a double click is heard Ensure the siderail is locked by pulling and pushing it Page4 8 QD2300 5 AvantGuardO Electric bed User Manual Lowering the long metal siderails position 1 4 WARNING If control pendant is present on the siderail then remove it See Unclipping page 4 46 To lower a long metal siderail Gripping the siderail by the upper bar Push slightly A the siderail to the head end then press and hold 1 the first unlocking button Press the second unlocking button 2 Only release the two buttons after starting to lower the siderail Rotate and push B the siderail downwards into the low position
72. urpose When the patient is restrained by straps all electric functions should be locked out When the patient is restrained with an abdominal strap a system used to restrict the ankles must also be used Failure to do so could result in patient injury or equipment damage 1 Only to be used in compliance with local regulations QD2300 5 AvantGuard Electric bed User Manual Page4 37 When required patient restraining straps must be tied to the proper handles provided The sleep surface has four handle positions seat thigh and foot section located on each side of the bed Thread the straps through the bars 4 WARNING Containment devices must not be used as a replacement for the nursing care required by the patient Even when they are correctly installed physical containment devices may become tangled and injure the patient or even cause death if the patient is agitated and confused Whenever containment devices are used the patient must be observed in accordance with legal requirements and protocol Failure to do so could result in patient injury or equipment damage 4 WARNING Containment devices must be secured to the articulated sections of the bed using appropriate attachment points in order to avoid injury to the patient Ad WARNING Never use containment straps for the ankles when the bed is in the seated position or the foot section is lowered Failure to do so could result in patient injury or equipment
73. vement policy Therefore specifications are liable to be altered without notice Technical specifications Type AvantGuard Reference LI158Bx Model 1200 Class according to IEC 60601 1 Type B Protection against harmful ingress of IPX4 water according to IEC 60529 Safe working load 185 kg 210 kg Intermittent operation 1096 3min 30min Maximum lifting load 551 16 Ib Bed weight no mattress or 330 69 1b accessories Electric shock protection Class I Voltage 230V AC 120V AC 100V AC Frequency 50 60 Hz 50 60 Hz 50 60 Hz Power supply unit 360 VA 360 VA 360 VA maximum power load Power supply unit 2AT 2 5AT 2 5AT fuse rating a See Bed model and country of use page 1 3 b If the total load patient mattress and accessories reaches between 185 kg and 210 kg the overload protection of the bed electronics may be activated depending on the weight distribution on the bed When a function is selected that is overloaded an alarm will sound and stop the selected movement This overload protection will not interfere with the emergency CPR function e Do not operate electrical functions continuously for more than 3 minutes in any 30 minute period when the bed is loaded at the safe working load value as this may damage electrical components QD2300 5 AvantGuardO Electric Bed User Manual Page9 1 E E B g Dimensions