Home
Spring MT(Z)
Contents
1. 11 6 Functions amp Operation I DC Start Function DC Start Function enables UPS to be started up when AC utility power is not available and battery is fully charged Just simply press the power switch to turn on the UPS Il Green Power Function These series are equipped with Green Power Function for saving power and protecting battery The feature of deep discharge protection is adoped on battery mode If no or light load is connected to the UPS it will automatically shut down after 5 minutes for energy saving while running on battery mode Disable by default The UPS will restart while AC recovery The green power function can be enable only by Winpower monitoring software lll AVR Automatic Voltage Regulation If the quality of the incoming mains is poor the AVR boosts a low incoming voltage or reduces a high one The load receives a voltage within the normal range IV Auto restart while AC recovery V Audio Indicator Audible Alarm Situation Sounding every 10 seconds Battery Mode Sounding every 3 seconds Battery Low Sounding every 3 seconds Overload Sounding every 1 seconds Faulty 12 7 Software Installation on your PC Connected by USB to a PC or notebook the Software enables communication between the UPS and the computer The UPS software monitors the status of the UPS shuts down the system before the UPS is exhausted and can remotely observe the UP
2. cooling vents This unit intended for installation in a controlled environment temperature controlled indoor area free of conductive contaminants Avoid installing the UPS in locations where there is standing or running water or excessive humidity and do not use it in any of the following environments o Any area with combustible gas corrosive substance or heavy dust o Any area with extraordinarily high or low temperature above 40 C or below 0 C and humidity of more than 90 o Any area exposed to direct sunshine or near any heating apparatus o Any area with serious vibrations o Outdoor The utility power outlet shall be near the eguipment and easily accessible In the event of an emergency press OFF button and disconnect the power cord from the AC power supply to properly disable the UPS The internal short circuiting of the UPS will lead to dangers such as electric shock or fire therefore do not allow liquids or any foreign object to enter the UPS No water containers such as a water glass or any other liquid containing vessels shall be placed on the top of the UPS so as to avoid such dangers as electric shock Please do not use the UPS in excess of the rated load capacity Unplug the UPS prior to cleaning and do not use liquid or spray detergent Risk of electric shock do not attempt to disassemble the unit No user serviceable parts inside Refer servicing to qualified service personnel If UPS is to be stored f
3. Line Interactive UPS Spring MT 500 Spring MT 750 Spring MT 1000 Spring MT 1500 Quick Start Guide EN Users E2011703 Qian Pinglian 2014 10 28 14 24 02 CONTENT IMPORTANT SAFETY INSTRUCTIONS ea 1 2601 RR E e E E E AE 4 2 Description of FOIS as nome 4 3 Package Contents sise eh jet na be ed in 4 4 Product OVO Wicca 5 5 Installation and Initial STANU cca 9 6 Functions amp Operation lievi 12 7 Software Installation on your PC 13 8 Maintenance ee eae ee ra srao ee mn vmro 14 9 Trouble S NOG UI nee 16 10 Specifications aaa 17 Users E2011703 Qian Pinglian 2014 10 28 14 24 02 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions for models Spring MT 500 750 1000 1500 that should be followed during installation and maintenance of the UPS and batteries This product is specially designed for PCs and it is not recommended for use in any medical equipment life supporting system and other specific important equipment Do not plug household appliances such as hair dryers microwave ovens or vacuum cleaners to UPS Do not attach a power strip or surge suppressor to the UPS Do not plug the UPS into its own output Connection to any other type of receptable other than two pole three wire grounded receptacle may result in shock hazard as well as violate local electrical codes To reduce risk of overheating the UPS do not cover the UPS
4. S via the Network enabling users to manage their system more effectively Upon AC failure or UPS battery low UPS takes all necessary actions without intervention from the system administrator In addition to automatic file saving and system shut down functions it can also send warning messages via SMS e mail etc e Use the bundled CD and follow the on screen instructions to install the software e Enter the following serial No to install software 511C1 01220 0100 478DF2A e After the software is successfully installed the communication with UPS has been established and a green icon will appear in the system tray math iam e Double click the icon to use the monitoring software as above e You can schedule UPS shutdown start up and monitor UPS status through PC e Detail instructions please refer to the e manual in the software IN Check http www ups software download com index htm from time to time to get the latest version of monitoring software 13 8 Maintenance I General The UPS is virtually maintenance free take care of proper environmental conditions and keep air inlets outlets free of dust Il Fuses If the AC input fuse is defect be sure it is replaced by a compatible fuse from the same make and type Never short circuit batteries When working with batteries remove watches rings and other metal objects and only use insulated tools III Battery module replacement A Read all safety rul
5. ct to Utility and Charge 000 Plug in the AC input cord to the 2 pole 3 wire grounded wall outlet For the best results we suggest charging the battery at least 6 hours with no load no electrical devices such as computers monitors rtc connected before initial use The unit charges its battery while connecting to the utility 6 hours III Connect the Loads Plug in the loads to output receptacles on the rear panel of the UPS Simply turn on the power switch of UPS unit and devices connected to the UPS will be protected by UPS unit A Do not attach a power strip or surge suppressor to the UPS IV Connect LAN cable Modem or Phone line for Surge Protection Connect for example a single modem or phone line into surge protected IN outlet on the back panel of the UPS unit Connect from OUT outlet to the computer with another phone line cable V Connect USB Cable To monitor the UPS status such as unattended UPS shutdown and start up by using bundled software please connect the UPS and PC with USB cable included 10 A NEVER connect a laser printer or scanner to the UPS unit because in rush current generated by motor s devices may cause the damage of the unit VI Turn On Off the Unit Turn on the UPS unit by pressing the On Off button Turn off the UPS unit by pressing again the On Off button
6. e with the same type of temperature operation battery environment or improper operation to battery If any abnormal situations occur that are not listed above please call service people immediately 16 10 Specifications Complete Series 500VA 750VA 1000VA 1500VA 220 230 240 VAC for HV models 110 120VAC for LV models 184 276 VAC for HV models 96 144VAC for LV models INPUT Voltage Voltage Range default OUTPUT 220 230 240 VAC 110 120VAC Voltage Regulation 10 6 of nominal voltage range Line mode Frequency Range 50 60Hz Frequency Regulation 1Hz Battery mode Transfer Time Typical 3 7ms 10ms max Waveform Pure Sine Wave PROTECTION Full protection Discharge overcharge and overload protection ENVIRONMENT Humidity 0 90 RH O to 40 C non condensing Less than 40dB OLine mode Less than 45dB Battery mode Voltage Noise Level Less than 40dB Monitoring Software WinPower included CAPACITY 500VA 750VA 1000VA aa oo gt dai m ui BATTERY Type amp Number ns oo 12V 7Ah x2 12V 9Ah x2 Charging Time 3 hours recover to 90 capacity Backup Time PHYSICAL LCD Indicator View Area 30mm x 30mm AC Mode Backup Mode 4 IEC 320 C13 outlets 8 IEC 320 C13 outlets 2 FR Outlets 4 FR Outlets Outlet 2 DIN Outlets 4 DIN Outlets 4 NEMA 5 15R outlets 8 NEMA 5 15R outlets 17 Gommunication USB port RJ11 RJ45 Surge Protection connector Dimension WxHxD aal 150mm x 209
7. es before replacing the battery Battery tray removal on tower models This operation must be performed when the UPS is switched OFF and unplugged from AC source A Remove the front panel B Disconnect the battery block by separating the two connectors never pull on the wires 14 C Remove the metal protection cover in front of the battery one screw D Pull the plastic tab to remove the battery block and replace it Mounting the new battery module Carry out the above instructions in reverse order e To ensure safety and high performance use only batteries with exactly same specifications e Take care to firmly press together the two parts of the connector during remounting 15 9 Trouble Shooting No LCD 1 Battery isn t connected 1 Reconnect battery display on the 2 Battery defect 2 Replace with the same type of front panel battery 3 On Off button is not 3 Press the On Off button again pressed Alarm buzzer 1 Overload of the UPS Verify that the load matches the beeps UPS capability specified in the continuously specs when AC 2 Power cord is loose Reconnect the power cord supply is properly normal When power 1 Overload of the UPS 1 Remove some non critical failure load back up time is 2 Battery voltage is too low 2 Charge battery 6 hours or shorten more 3 Battery defect due to high 3 Replac
8. mm x 340mm 240mm WEIGHT Net weight 6 3kg 6 8kg 10 5kg 11 5kg 18 614 01865 00 19
9. on USB port IEC outlet Fan Rear Panel FR 500VA 750VA N 7 oE o 2 ala i G O O DIS Ir id 7 AC input RJ11 RJ45 LAN Modem phone line protection USB port FR outlet Rear Panel DIN 500VA 750VA 1000VA 1500VA a GE BE lo TI AC input RJ11 RJ45 LAN Modem phone line protection USB port FR outlet amp Fan 1000VA 1500VA amp AC input RJ11 RJ45 LAN Modem phone line protection USB port DIN outlet Rear Panel NEMA 500VA 750VA Fer N 9 D DI A og 00 ne i Ly AC input RJ11 RJ45 LAN Modem phone line protection USB port NEMA outlet AC input RJ11 RJ45 LAN Modem phone line protection USB port DIN outlet Fan 1000VA 1500VA 3 IN A le s Pa e Pa of eo Oa a Nese ii Go m gt E PE SPE o PO AC input RJ11 RJ45 LAN Modem phone line protection USB po
10. or a long time it is recommended to recharge the batteries by connecting the utility power to UPS switch ON once a month for 24 hours to avoid a full battery discharge In case smoke is found coming out from the device please cut off the power supply quickly and contact the distributor The UPS contains one two large capacity batteries So the shell shall not be opened otherwise such dangers as electric shock will be caused If any internal overhaul or replacement of the battery is required please contact the distributor Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions Keep unauthorized personnel away from batteries A battery can present a risk of electrical shock and high short circuit current The following precautions should be observed when working on batteries o Remove watches rings or other metal objects from the hand o Use tools with insulated handles and wear rubber gloves and boots o Do not lay tools or metal parts on top of batteries o Disconnect charging source prior connecting or disconnecting batteries terminals When replacing batteries replace with the same type and number of the sealed lead acid batteries The maximum ambient temperature rating is 40 C Do not dispose of battery or batteries in a fire The battery may explode Do not open or mutilate the battery or batteries Released electrolyte is harmful to the
11. rt NEMA outlet amp Fan lll LCD description N AVR IAN TLI LIT Min 2000 81816 wa IV UPS setting through the LCD Release scroll down button to select menu UPS ON amp AVR mode Battery mode O Internal fault amp Output load level Q Battery level Input measurements G Output measurements G Measuring unit maa Z 5s E 2s ii gc pmo wa Output voltage Alarm Em Ha Rim OFF FE 225 ja ri 235 gt Sensitivity a zu lai z la re o Save the new value e LCD will shut off if there is no activity for 3 minutes 1 In low sensitivity mode Lo UPS will tolerate more fluctuations in power and will go on battery power less often If the connected load is sensitive to power disturbances keep the sensitivity as Standard Std 5 Installation and Initial Startup A Before installation please inspect the unit Be sure that nothing is damaged I Placement amp Storage Conditions Install the UPS in a protected area that is free of excessive dust and has adequate air flow around the unit and is free from excessive dust corrosive fumes and conductive contaminants Please place the UPS away from other units at least 20 cm to avoid interference Do NOT operate the UPS where the temperature exceeds 0 40 C and the humidity is over 0 90 RH e 20CM lt gt Il Conne
12. skin and eyes It may be toxic Icon on the rating label stands for phase symbol This pluggable type A equipment with battery already installed by the supplier is operator installable and may be operated by laymen During the installation of this equipment it should be assured that the sum of the leakage currents of the UPS and the connected loads does not exceed 3 5mA Attention hazardous through electric shock Also with disconnection of this unit from the mains hazardous voltage still may be accessible through supply trom battery The battery supply should be therefore disconnected in the plus and minus pole of the battery when maintenance or service work inside the UPS is necessary In the event that there is fire occurring in the vicinity please use dry power extinguishers The use of liquid extinguishers may give rise to the danger of electric shock Operate altitude should not exceed 2000m This product complies with the safety and environmental regulations in If the time arises to throw away your product please recycle all the components possible Batteries and rechargeable batteries are not to be disposed in your domestic waste Please recycle them at your local recycling point Together we can help to protect the environment CE x 1 Introduction Spring MT series is an intelligent and compact line interactive UPS Uninterruptable Power Supply which is designed to protect your personal computer or sensitive elec
13. tronic equipments from all forms of power interference including complete power failures It is equipped with many features that allow any attached equipment to operate longer and more reliability 2 Description of Features Easy to use and install utilized microprocessor control to maximize the reliability and efficiency Equipped with built in boost and buck AVR function DC Cold start function Green Power Function for energy saving Auto restart while AC recovery Provides AC Overload protection RJ11 RJ45 in out LAN Modem Phone line protection IEC FR DIN NEMA various output 3 Package Contents You should have received the following items inside of package AC Input Power Cord UPS Unit USB Cable AC output Power cord only for IEC models Software CD User Manual 4 Product Overview I Front Panel 1 Il Rear Panel IEC 500VA 750VA 3 PH o 0 0 o A 058 a AC input RJ11 RJ45 LAN Modem phone line protection USB port IEC outlet 17 ON OFF button Scroll down button Mute button LCD display 1000VA 1500VA AC input RJ11 RJ45 LAN Modem phone line protecti