Home

EYW300 novaWeb Configuration - Sauter Building Control Serbia

image

Contents

1. Benutzer user2 sauter In general the access to the novaWeb pages is controlled only by the user level and the relevant password The user name can be chosen freely The guest login can be allowed or blocked A new user password can be added in the last line 9 1 1 Settings and login For the various areas the default settings for the password are as follows User user O sauter Service service sauter System Wartung ml 9 sauter You are strongly advised to change the passwords only then is the system protected against unauthorised access 7001056003 A Sauter Systems 31 NS 32 EYW300 novaWeb Configuration ecco 9 1 2 User Access Levels table Login The illustrated data points and the possible functions according to the different user levels can be seen in the following table Main Pages Pages Regul Regulation ations s Overview Install System ations View Functional Description Schematic Service View System Maintenanc e View Alarm Actions Display Changing setpoints Display History Changing time schedule Changing setpoints Switching commands Push button commands Reset counters Modification of compensation curve Display Display Display Display Display Acknowledging alarms Event Pages 1 to Display 7001056003 A Data points sp tc sp SW pb met pb X1 x6 y1 y6 eco mn mx al Guest U
2. The novaWeb has an integrated firewall Follow the Firewall settings for WAN link to go to the firewall configuration menu 7 3 1 Settings for the WAN firewall The settings for the WAN firewall can be found under Settings Network only if WAN is specified Change firewall settings for WAN Follow this link to go to the firewall configuration menu The following input menu appears on the screen 7001056003 A Sauter Systems 23 SF 24 EYW300 novaWeb Configuration 56500 TCP IP connections Firewall Einstellungen f r WAN O Aus 9 Basic erlaube Telnet FTP und ping High erlaube nur sehr eingeschr nkten Zugnf NAT PORT IP 1 th El UJ pb The firewall can be switched off e deactivated Moreover there are two settings for the firewall either Basic or High Depending on the selection made the following services will pass the firewall Transfer Service Protocol In Out Basic High dport sport dport sport Ping ICMP X Telnet SSH TCP 22 1024 1024 23 X SFTP TCP 1024 22 11024 1024 1024 22 x HTTP TCP 80 1024 1024 80 X X SMTP TCP 1024 25 25 1024 X X DNS TCP UDP 1024 53 53 1024 X X NTP UDP 123 123 123 123 X X DHCP UDP 67 68 67 68 67 68 67 68 X X DHCP UDP 67 68 67 68 67 68 67 68 X X All other services are rejected If more devices are connected to the novaWeb s LAN port they can be addressed via the WAN port of the novaWeb e g remotely via the internet For this purpose the relevan
3. vm n amp m um VE atn ante Mounting Bracket 2 Retention Screws sM9198 UOIJUSJO Y 1949818 Bununo 7001056003 A Sauter Systems 11 EYW300 novaWeb Configuration ecco NV Installation 12 7001056003 A Sauter Systems o EYW300 novaWeb Configuration Housing NV 5 Housing The on off switch which lights up in blue is on the front of the novaWeb housing HDD LED Reset Button Power Button The following ports are on the rear COM1 LAN WAN Power ojo epe j iS Olecens ques e e e B12092 RS422 COM2 RS485 nova291 Modem Port Type Cable Connection Power Terminals on power supply unit Power supply unit plug p Pply optional RS232 null modem COM2 nova291 DB9 article no 38630 1001 novaNet 291 LAN RJ 45 CAT 5 Ethernet PC or LAN WAN RJ 45 CAT 5 Ethernet PC or LAN The external power supply unit for the novaWeb server EYW300F001B can be ordered direct from the supplier Kabona Sweden using the following numner 0920570010 7001056003 A Sauter Systems 13 EYW300 novaWeb Configuration ecco NU Housing 14 7001056003 A Sauter Systems o EYW300 novaWeb Configuration novaNet connection JA 6 novaNet connection 6 1 RS232 connection to novaNet291 For the access to the novaNet you need a novaNet291 as a router The novaNet291 must have a recent EPROM release at least F and should
4. NO CARRIER elc H Hook Status HO On hook Hang up Store the Sn r value of rin 90 20 Set register O to O Do not accept dial in S register n Pick up the receiver after SO 1 Set register O to 1 or 2 or 3 first 1 ring Data Terminal Hang up reset the modem amp D amp D3 and return to command ise ene mode upon DTR This is needed for the SE amp DO Signal ignored as NOGEN SE your manual for more information amp C Carrier detect amp C1 Indicates remote carrier Usual preferred default 7001056003 A Sauter Systems 27 EYW300 novaWeb Configuration Wesco NV TCP IP connections 7 3 3 3 Dial in As soon as the modem is configured to accept incoming calls SO 1 it is possible to connect to novaWeb s dial in support Both terminal e g via HyperTerminal and PPP HTML browser are supported Use the following when connecting using PPP to novaWeb e Username cpp e Password blixten N B Fora more detailed description of dial in see the operating instructions 15 4 2 7 3 3 4 Dial out If Dial number Username and Password are entered the dial out connection is activated used for alarm and DAQ sending purposes The connection will use dial on demand and will hang up after time out seconds without traffic 7 3 3 5 Dynamic internet address In some cases it is not possible to get a static internet address since the operator offers only dynamic addresses through DHCP The problem with a dynamic address i
5. o EYW300 novaWeb Configuration WY EYW300 novaWeb Configuration Manual 7001056003 A This description corresponds to the current program release version 2 8 3 Subject to change without notice 7001056003 A Sauter Systems 1 EYW300 novaWeb Configuration ecco NL 2 7001056003 A Sauter Systems o EYW300 novaWeb Configuration Table of contents ANTOCUCIO eSI 5 Z novaWeb documentation a 7 SY Requirements iaa oc 9 3 1 WD BROS EF E alistan iaa 9 3 1 1 FTP Clear id o 9 3 1 2 Tested connectivity devices modems and router 9 4 1 gt 10 AUN OW rac nada 11 4 1 A A O SEERE A 11 NEN NOUS UNG wessen ABEL E 13 O NovaNet ConNeclon reinen s 15 6 1 RS232 connection t nov aN t29 dius dada 15 6 1 1 novaNet connection to automation stations esee 15 6 1 2 Manual garbage collection eeeeeseeeeeeereenree nen 16 56 13 ASS EEG HOR ar Se isnt een M dcr p SEU ERE 17 O4 a E nodules tertias veu GRE eV eA da 18 E LO Vil CONNECTORS mE ee 19 7 1 General SCUINGS usd ida ia 19 s FAO SE TUUM n 19 732 SP see A O O ECL UE dan 19 Telco POM MUMDECIS T a 19 ri MP Eore ieelniarzeuis LAIN LE 20 7 2 1 a A 21 7 2 1 1 DHGP server ide EAN ra er 21 7 3 Remote connection WAN 20022400200000nn nano nenn nenn nenn nnne nenne nenn une nennen 22 7 3 1 Settings for the WAN firewall c
6. for SMTP servers which need no authentication The following sections describe the settings that can be made 8 1 Mail server novaWeb runs an embedded mail transfer agent Therefore no external server is needed to send the e mails The e mail server of the recipient will be discovered via a DNS request Who handles e mail to xyz In some configurations however it is desirable to use an existing mail server on the customer s LAN which handles all deliveries on behalf of novaWeb This might be the case due to firewall configurations If you specified the host name with domain name e g embweb02 ch sauter bc com then you can specify an e mail server without a domain name e g only imap instead of imap ch sauter bc com 8 2 Sender Normally mail servers do not forward e mail for unknown users Therefore a user id should be specified when sending e mail Furthermore if the recipient cannot be reached the message will be returned to the sender To make sure that no messages are lost you should enter your mail address if you want to be informed of any unreachable recipients 8 3 Masquerade Masquerading is needed only if you have firewalls with such rules as Accept e mail only from IP x x x x 7001056003 A Sauter Systems 29 30 EYW300 novaWeb Configuration 6500 Advanced e mail settings 8 4 E mail to SMS novaWeb sends out e mails only If you need further services such as SMS messages we recommend that you
7. name standard is used the stations are shown in the AS view Alarm Data acquisition System maintenance Clock Values Devices Login Network Language Settings Devices Garbage collection Start Choose station number 32000 for all Preferred view AS selection el Enter station number betj HA structure Intervals are written as nn nn Separate stations and inLNami Ex 11 22 1001 1019 1033 Leave empty to use all AS 18 7001056003 A Sauter Systems o EYW300 novaWeb Configuration TCP IP connections NV 7 TCP IP connections There is always a local Ethernet connection basically for service access and the possi bility of a remote connection The remote connection could be either an Ethernet connection e g for a company LAN or an internet connection or a dial up connection For convenience the local port will be called LAN and the remote port WAN even if this does not always fit the standard designation Select the Settings menu item in the left frame and then choose the Network item from the menu in the main frame to go to the settings described in this section 7 1 General settings In all set ups the LAN port indicated as LAN2 on the housing is used as a local private network 7 1 1 Host name Host Name w dcsautr Da The host name is used for both the LAN and the WAN connections 7 1 2 DNS server The Domain Name Service DNS makes it possible to address devices with
8. 00 novaWeb Configuration ecco JA General security measures 42 7001056003 A Sauter Systems o EYW300 novaWeb Configuration Appendix lt 14 Appendix 14 1 Modem command set 14 1 1 Basic Hayes command set Command Description Comments AQorA Answer incoming call A Repeat last command Do not preface with AT Enter usually aborts BO or B Call negotiation V32 Mode CCITT Answer Seq B1 Call negotiation Bell 212A Answer Seq B2 Call negotiation Verbose Quiet On Answer Dial the following number and then handshake in originate mode p Pulse Dial T Touch Tone Dial W Wait for the second dial tone D Dial Pause for the time specified in register S8 usually 2 seconds Remain in command mode after dialling Flash button telephone receiver hang up for a half second as in transferring a call L Dial last number EO or E No echo Will not echo commands to the computer E1 Echo ba in BADET to the computer so one can HO Hook status On hook hang up H1 Hook status Off hook phone picked up Inquiry information or This command is very model specific I0 usually or I returns a number or code while higher numbers 7001056003 A interrogation often provide much more useful information Sauter Systems 43 lt 44 Command LO or L L1 L2 L3 MO or M M1 M2 NO or N N1 O0 or O 01 QO or Q1 Q1 Sn Snzr VOor V V1 XO or X X1 X2 X3 X4 ZO or Z 7001056003 A EYW300 novaWeb Configuration e
9. 4 1 2 Extended Hayes command set Command amp BO or amp B amp B1 amp B2 amp CO or amp C1 amp C1 amp DO or amp D amp D1 amp D2 amp D3 amp FO or amp F amp F1 amp F2 amp F3 amp GO or amp G amp KO or amp K amp K1 7001056003 A Description Retrain parameters Retrain parameters Retrain parameters Carrier detect Carrier detect Data Terminal Ready DTR Data Terminal Ready DTR Data Terminal Ready DTR Data Terminal Ready DTR Factory defaults Factory defaults Factory defaults Factory defaults Guard tones Local flow control Local flow control Comments Disable auto retrain function Enable auto retrain function Enable auto retrain but disconnect if no line improvement over the period dictated by s7 Signal always on Indicates remote carrier usual preferred default oignal ignored this is modem specific so refer to your manual If DTR goes from On to Off the modem goes into command mode some modems only Some modems hang up on DTH transition from On to Off this is the usual preferred default Hang up reset the modem and return to command mode upon DTR Generic Hayes compatible defaults This is usually a good thing to use in your init string since the amp F1 amp F3 settings can vary among modems and they may actually be the cause of connection problems since you never know exactly what Brand X s amp F2 really changes O
10. FAQ Frequently Asked Questions e Application Report 8 7001056003 A Sauter Systems o EYW300 novaWeb Configuration Requirements NV 3 Requirements 3 1 Web browser A standard HTML 4 01 compliant web browser which supports frame based pages is needed for optimal access to novaWeb pages For standard Windows PCs we recommend the current versions of MS IE V6 0 or higher or Mozilla FF V1 7 or higher Access via a smart phone or a PDA is also possible Due to the relative small size of the screen of these devices we recommend you to use a special entry page without frames or to bookmark the content page as one of your favourites for more information see below For the session management cookies must be enabled Please refer to the user manual for more details about setting cookies language settings and access to your site 3 1 1 FTP client A standard FTP client is needed for transferring user specific menus and modified alarm texts to the novaWeb server Function descriptions or pictures can also be transmitted via FTP Even if it is possible to ftp with standard Windows tools we recommend the use of a professional ftp client like Filezilla http filezilla sourceforge net Make sure the firewall is set to allow ftp communication settings network firewall basic security and that you use passive mode For security reasons the FTP access is replaced by an encoded SSH access since 2 8 1 For data exchange Filezilla c
11. a name instead of a numerical IP address The names are resolved via the so called DNS servers They manage and update the lists that contain the assignments of individual IP addresses to names Scroll down the page for network settings and you will reach the DNS server input field shown here DNS Server DNS 1 101 520 Neccessary for static adresses and in cases when not supplied dynamically DNS 2 for either LAN or WAN The IP addresses of two DNS servers can be entered They can be located on either the local area network LAN or the wide area network WAN 7 1 3 Port numbers To allow the correct service to be used for a device it is necessary to use the correct IP address and also to address the correct port WWW Port 80 Standard is 80 If modified then port should be higher than 1024 Ex 5080 If Hypertext Transfer Protocol HTTP is used port 80 is normally used However it may be advisable to use a different port If another port is to be used for novaWeb it can be specified in the relevant field 7001056003 A Sauter Systems 19 EYW300 novaWeb Configuration ecco NZ TCP IP connections 7 2 Local connection LAN The novaWeb is linked to the operating computer via an Ethernet connection The physical link to the novaWeb is made via the LAN connection using a suitable patch cable with RJ45 plugs The connection may be made in two ways e Via a standard Ethernet cable patch cable to a hub or switch This hub or switc
12. an still be used but TCP port 22 must be employed Filezilla is freeware and can be installed as a portable application on a USB stick http portableapps com The following access data are required for the novaWeb User name sautersystem password sl 9 sauter 3 1 2 Tested connectivity devices modems and router According to the novaWeb access type a modem or router could be necessary We recommend the use of the following devices Connection Manu Device Connection novaWeb Website facturer Port Analogue Westermo www westermo com TDW 33 RS232 COM1 modem ISDN ZyXel www zyxel com product index php onmi net Lite RS232 COM 1 GSM Sony www sonyericsson com GM29 RS232 COM1 Ericsson ADSL ZyXel www zyxel com product index php Prestige 650 Ethernet LAN Router ME 7001056003 A Sauter Systems 9 EYW300 novaWeb Configuration W ecc NV Requirements 10 7001056003 A Sauter Systems o EYW300 novaWeb Configuration Installation NV 4 Installation You can install the novaWeb server within a cabinet or use it as a desktop device 4 1 Fitting To fit into a cabinet use the fitting kit 0920240010 and affix the unit at the rear of the novaWeb housing vera YITO 2060XPE R10 c TI gn vou LOUER SEE ZA x cx PN CA07001547 EE ware ee raci n roen tht v t mir Mounting Bracket 2 Retention Screw Holes S98 OH Maos uonuaejeyM Joype g Bunyunoy i Ei woe VITO 2060XPE R10 Lo
13. be set to a router connection with 38400 bit s only switch 3 set to on The novaNet address of the novaNet291 will be set to 31777 by novaWeb so no other PC device can use this address within the novaNet Connect the COM2 terminal of your novaWeb device via a standard DB9 null modem cable Sauter accessories number 386301 001 with the COM terminal of your novaNet291 novaNet EIA232 EY36001 EYZL291 novaNet ElA232 EYW300 EYZL291 6 1 1 novaNet connection to automation stations From the RJ11 or the a b terminal of the novaNet291 use a twisted pair cable to connect the novaNet devices according to EY3600 automation station manual 7000968 00x 7001056003 A Sauter Systems 15 NV EYW300 novaWeb Configuration ecco novaNet connection 6 1 2 Manual garbage collection Select the Settings menu item in the left frame and then choose the Devices item from the sub menu in the main frame to go to the following display on the screen Alarm Data acquisition System maintenance Clock Values Login Network Language settings Devices Garbage collection eun Choose station number 32000 for all Preferred view Na ming stand ard AS selection Change Enter station number between 0 and 31 44 Intervals are written as nn nn separate stations and intervals with comma Leave empty to use all AS Ex 11 22 1001 1019 1033 After each garbage collection novaWeb re reads the conten
14. cco Appendix Description Comments Speaker loudness Modems with volume control Off or low volume knobs will not have these options Low volume Medium volume Loud or high volume Speaker off M3 is also common but different on many brands Speaker on until remote carrier detected i e until the other modem is heard Speaker is always on data sounds are heard after CONNECT Handshake speed Handshake only at speed in S37 Handshake at highest speed greater than S37 Return online See also X1 as dial tone detection may be active Return online after an equaliser retrain sequence Off displays result codes user sees command Quiet mode responses e g OK uiermode On result codes are suppressed user does not see responses Query the contents of S register n Store Store the value of r in S register n Verbose Numeric result codes English result codes e g CONNECT BUSY NO CARRIER etc Smartmodem Hayes Smartmodem 300 compatible result codes Usually adds connection speed to basic result codes e g CONNECT 1200 Usually adds dial tone detection preventing blind dial and sometimes preventing ATO Usually adds busy signal detection Usually adds both busy signal and dial tone detection Reset modem to stored configuration Use ZO Z1 Reset etc for multiple profiles This is the same as amp F for factory default on modems without NVRAM non volatile memory Sauter Systems o EYW300 novaWeb Configuration Appendix lt 1
15. cooococoocncoccccocococonnnnoncnnnnncnonanonnnons 23 132 p rere 25 7 932 NOTE RN DEED 26 7 3 3 1 DIaFNtaDlei 2 keit este lea 26 ose MODEN Secta adi 27 73933 MEME BITTER 28 Kon MEME RIT SRL IT TU 28 7 3 3 5 Dynamic internet addresS cooccoooncconnoccninonncconcconcnnnnonanonnanonancnnnnos 28 7 3 3 6 ACCESS via a modem portal ooccocccocccocncccnoccncnocncononanonanonanenanenanos 28 8 Advanced e mail settings we 29 8 1 VIUERE TRU TU 29 82 uei 29 G3 ANTES TAS RETO E ETE EE 29 84 Esmalltoslsssmnditimdus ei uda taie aia Mid dtd dut auf 30 8 5 E mail to WAP e mail to WAPA Wal Susini 30 7001056003 A Sauter Systems EYW300 novaWeb Configuration ecco Table of contents ES Mio 31 AS e ride 31 9 122 User Access Levels table ori 32 10 Language selection e 35 11 Soflware Update sun ein 37 12 BACK UD a 39 12 1 Crede DA i n 39 12 2 Restore bak UD E e 40 13 General security measures uuusnauuennanunnnnnonnnnunnannnnnnnnnnununnnnnnnnannnnnnunnunnnnnanunnnnnnnnn 41 St General SRM T T MM 41 Sa Edema Walls PT 41 13 1 3 Virtual private netwoks VPN cooccccccnccccncccnccccococncnnnonnnnnnnnonncnnnnnonanonnnoss 41 IDEE ge ode 43 141 Modem command Sel itii eue ei EFE troc irn Naar 43 14 1 1 Basic Hayes command set u222202400020000nen nenn nano nen nennen nnne nnne nnns 43 14 1 2 Extended Hayes command Set cccccsececeeee
16. e settings 40 7001056003 A Sauter Systems o EYW300 novaWeb Configuration General security measures NY 13 General security measures Depending on the importance of the monitored site from simple heating to danger to life security needs can vary tremendously Please discuss your specific security needs with an IT professional He will advise you on password management regular change etc firewalls and other security measures 13 1 1 General issues In general you should be aware of the following issues when making any decision regarding your network configuration e Confidentiality Privacy e Integrity e Authentication e Authorisation e Non Repudiation e Availability Access 13 1 2 External firewalls Even with the included firewall you should take extra care when connecting to the internet A standard internet server is always protected by an external firewall This could be included in the access router e g ADSL router or a whole demilitarised zone is set up 13 1 3 Virtual private netwoks VPN If access to novaWeb is needed only from certain places a virtual private network VPN can be set up There are a lot of different set ups but in general a VPN server provides an access point for a VPN client to connect via an IPSec or PPTP or SSL connection to a LAN site e g the novaWeb installation Please check with your IT professional for more details 7001056003 A Sauter Systems 41 EYW3
17. e supplied by the customer or the internet supplier Preferably static IP addresses should be used The IP address of the gateway has to be added for access from other networks The DNS server provides the name resolution to IP addresses If dynamic IP addresses are used this IP address has to be forwarded to a dynamic name service provider like dyndns org or an equivalent service In this way it is possible to reach novaWeb via an IP name which is assigned by the DNS server See also Dynamic internet address 22 7001056003 A Sauter Systems o EYW300 novaWeb Configuration TCP IP connections NV The next illustration shows the input field for WAN settings WAN O Nicht benutzt ODHCP Statisch IP Adresse 192 168 10 11 Netzmaske 255 255 255 0 Gateway Einwahl Baud rate 57600 z B 57600 Telefonnummer z B 033101112 0w033101112 Benutzer webland Wie vom Internetprovider angegeben Passwort eeeeesseeece Wie vom Internetprovider angegeben limeout 100 in Sekunden ohne Verkehr bevor Aufh ngen Init 1 ATQUV1HO AT nr 1 zB ATQOV1HO Int 2 ATSO 08D28 01 AT nr 2 zB ATSO 0 amp D3 amp C1 N Init 3 AT nr 3 zB AT CGDCONT 1 TP static vodafone net F rewall Einstellungen f r WAN You can select whether not to use the WAN connection to assign the IP addresses dynamically mark DHCP or to work with static IP addresses It is also possible to implement WAN access via modem This option is described in the modem section
18. h is then connected to the computer s Ethernet interface via an Ethernet cable World Wide Web iene Alternatively e Via a crossed Ethernet cable crossover patch cable straight to the corresponding computer interface on the network card The status of the network connection can be seen from the LEDs for the Ethernet interfaces If the right hand green LED is lit the Ethernet connection is established If the left hand LED flashes yellow this means that data are currently being transmitted traffic 20 7001056003 A Sauter Systems o EYW300 novaWeb Configuration TCP IP connections NV 7 2 1 IP addressing LAN DHCP 9 Statisch IP Adresse 10 1 247 153 Netzmaske 255 255 0 0 Gateway All devices within this local network novaWeb and PCs should be set to the same network class This means they have the same netmask with different IP addresses within the same network class range For example the novaWeb could stay at 10 10 10 11 and the PC could have a similar IP address like 10 10 10 10 within the same IP range specified by the netmask Standard private network addresses are Network Class Start IP Address End IP Address Netmask Class A 10 0 0 0 10 255 255 255 255 0 0 0 Class B 172 16 0 0 172 32 255 255 255 255 0 0 Class C 192 168 0 0 192 168 255 255 255 255 255 0 This is an international standard but variations are possible For instance a class A IP address can also be combined with a
19. ing air conditioning or other systems in buildings Cache A local copy of data which have been fetched from a remote host to reduce access time Cookie A cookie is a piece of information sent by the web server to the client e g for identification purposes session management CSD Circuit Switched Data is the standard type of transmission for GSM with 14 4 kBit s which is traditionally used for voice transmission CSV Comma Separated Variables is a tabular data format which uses delimiters commas tabs semicolons etc to separate fields DNS Ina Domain Name System one or more servers store and provide information such as the IP addresses of each host and the mail exchange servers FF Mozilla Firefox GMT Greenwich Mean Time is the time at O degrees geographic longitude at Greenwich near London UK International time stamps are normally indicated as Offset to GMT GPRS General Packet Radio Service is a packet switched data transmission which is also much faster than CSD also up to 56 kBit s However the connection is in theory always established but you pay only for the actual data volume GSM Global System for Mobile Communication is a worldwide standard for mobile phones HSCSD High Speed CSD bundles several CSD transmission channels together to allow higher transmission rates normally up to 56 kBit s HTML HyperText Mark up Language is a language for web pages links are marked up HTTP HyperText Transfer Pr
20. n class B or C netmask as is done in the ex works settings IP address 10 10 10 11 and netmask 255 255 255 0 The novaWeb can be configured with a static IP address see the illustration for example or an IP address can be assigned dynamically For dynamic assignment of the IP address mark DHCP in the LAN input field 7 2 1 1 DHCP server in the LAN DHCP Server starten auf LAN Nein O Ja ndern I O Adressen R It is also possible to let the novaWeb act as a DHCP server on LAN which automatically assigns IP addresses to any computers connected This makes it easier for the service personnel to connect On some installations only Dynamic internet addresses can be used which is also possible with the novaWeb but needs some extra work Advanced e mail settings are necessary if you plan to use an existing e mail server or have other restrictions on the network for mail delivery 7001056003 A Sauter Systems 21 EYW300 novaWeb Configuration 56500 NZ TCP IP connections 7 3 Remote connection WAN This is the alternative used when connecting to an existing LAN at the customer site or if there is a direct connection to the internet Often both of these apply since the novaWeb can often access the internet through a customer s LAN Ethernet driver and service connection Customer LAN or Internet SO oe Modem nova291 RS232 serial driver B12016 Network settings for WAN must b
21. n the other hand it pays to try out the other options below many people s problems can be solved by replacing a complicated init string with a simple amp F2 or the like However if you re building an init string it is best to start with a simple amp F and not use the customised form of defaults Factory defaults tailored to an IBM PC compatible user Factory defaults for a Mac with software handshaking Factory defaults for a Mac with hardware handshaking Disable guard tones Disable local flow control Enable RTS CTS hardware local flow Sauter Systems 45 lt 46 EYW300 novaWeb Configuration ecco Appendix Command amp K2 amp K3 amp K4 amp LO or amp L amp MO or amp M amp PO or amp P amp P1 amp QO or amp Q amp Q5 amp Q6 amp Q8 amp Q9 amp S0 or amp S amp S1 amp TO or amp T amp U0 or amp U amp U1 amp VO or amp V1 WO or amp W amp YO or amp Y 8 Y 1 amp Zn x 7001056003 A Description Local flow control Local flow control Local flow control Dial mode Error control mode Pulse dialling ratio Pulse dialling ratio Error control mode Error control mode Error control mode Error control mode Error control mode DSR action select DSR action select Self test Trellis code modulation Trellis code modulation View active Store profile Select configuration loaded at power up Select configuration loaded at power up Soft re
22. otocol is the protocol used to transfer HTML based web pages over a TCP IP connection IE Microsoft Internet Explorer 7001056003 A Sauter Systems 47 NA 48 EYW300 novaWeb Configuration ecco Abbreviations and terminology IP Internet Protocol is the standard network layer protocol for network communication ISDN Integrated Services Digital Network is a standard for digital telephone communication ISO International Organisation for Standardisation is an international non governmental standard setting organisation IT Information Technology Java Object orientated programming language developed by Sun JavaScript Object orientated scripting language developed by Netscape MFA Data point address within an AS MS Microsoft PDA Personal Digital Assistants are hand held devices which usually include an organiser some viewers and further programs RAM Random access memory is the memory used to store the program and data during execution as long as the device is running RT Real Time Clock SIM Subscriber Identity Module is a card in which a key is stored to identify a mobile phone GSM subscriber Smartphone Smartphones are hand held devices which combine the functions of PDAs and mobile phones For more information refer to web based encyclopaedias such as Wikipedia O 2003 by Sauter AG Im Surinam 55 CH 4016 Basle Switzerland va 7001056003 A Sauter Systems
23. rm POTS ISDN GSM Modem In general it should be possible to use any Hayes compatible modem Testing however has been limited to the above mentioned modems The connection type could either be POTS Plain Old Telephone Services ISDN or GSM 7 3 3 1 Dial in table Dial up Internet Dial in access B12017 novaWeb modem Browsing device Connection Type POTS ISDN GSM Smartphone e g P10i GSM X X X POTS X X PC ISDN X X X GSM X X X 7001056003 A Sauter Systems o EYW300 novaWeb Configuration TCP IP connections NV 7 3 3 2 MODEM settings Name Value Description Baud rate 57600 Ex 19200 Dial number 0616831830 Ex 033101112 0w033101112 Username From internet operator Password From internet operator Timeout 300 in seconds without traffic before hang up Ex 300 Init 1 ATQOV1HO AT command 1 Ex ATQOV1HO Init 2 ATSO 0 amp D3 amp C1 AT command 2 Ex ATSO 0 amp D3 amp C1 Init 3 AT command 3 Ex AT CXXSN 2 N6 There are three init strings available to configure the modem for the correct behaviour Normally the AT commands QO V1 HO S020 amp D3 amp C1 or equivalent must be configured for correct operation N B To send the character to the modem enter W due to character handling in the web server and Linux AT Attention Display result codes user Q Quiet Mode QO Quiet Mode Off sees command responses e g ok e g CONNECT BUSY V Verbose V1 English result codes
24. s Devices Log in Network Language settings Setting values setting values are writable values such as controller parameters setpoints etc save setting values to FLASH for later restore Restore Setting values from FLASH Non matching points are ignored Backup Settings settings can be backuped from one device and restored on the same or another device Create a back up by clicking Back up settings N B The back up is created as a tgz file Restore Settings The settings are restored via the tar file in the back up M chten Sie diese Datei offnen oder speichem Name wdc bup taz gi p tg Typ Winzip File Von 10 10 10 11 Vor dem Offnen dieses Dateityps immer bestatigen Dateien aus dem Intemet k nnen n tzlich sein aber manche e Dateien k nnen eventuell auf dem Computer Schaden annchten UL ffnen oder speichem Sie diese Datei nicht falls Sie der Quelle nicht vertrauen Welches Risiko besteht 7001056003 A Sauter Systems 39 EYW300 novaWeb Configuration W ecc YP Back up 12 2 Restore back up A back up is stored as a tgz file but a tar file is needed for a restore so take the following steps in order to convert the tgz file into a tar file Open the tgz file using Winzip Answer the question Should WinZip decompress with NO Drag and drop the tar file to a place of your choice Carry out a restore with the created tar file using Restor
25. s how to know what the current address is so that you can connect to novaWeb s web server A number of companies such as dyndns org offer a solution to this problem by providing a dynamic DNS service This is done by registering a sub domain such as wdc dyndns org and then using a special client application to inform the dynamic DNS which address is currently assigned to the novaWeb by the operator To periodically check and update the current address an ADSL router with this functionality is normally used 7 3 3 6 Access via a modem portal If you do not want the novaWeb to be connected to the internet constantly but you still wish to access via the internet you can use a Modem Portal Service Modem Portal Services provide access to the web server over the telephone network An internet connection is established as soon as a user wants to access a web page For further details search the internet for modem portal providers e g www emazy com 28 7001056003 A Sauter Systems o EYW300 novaWeb Configuration Advanced e mail settings x 8 Advanced e mail settings Through the Settings menu item in the left hand frame and then the Network menu item in the main frame you come to the page that also contains the Advanced e mail settings If you scroll down you reach the following input field Sender Ex novaWeb sauter bc com Mail server Ex smtp customer dom Masquerade Ex 10 11 12 13 N B No support is provided
26. seeeseeeeeeeeneeeeeeeeseeeseeeeaeeens 45 15 Abbreviations and terminology e eere ree eere eere rennen nnn nn 47 7001056003 A Sauter Systems o EYW300 novaWeb Configuration Introduction NV 1 Introduction novaWeb is an embedded web server that enables you to visualise your installation via a standard web browser Special attention has been put on a light weight interface pure HTML without ActiveX Java etc to allow for fast access even with very simple devices like smartphones According to your login level you can visualise any states or measurements modify setpoints and commands or modify any settings Alarms and events like the change of values can be sent to up to six e mail recipients Furthermore novaWeb can send out an e mail to transfer historic values for billing or long term storage Thanks to the remote access facility you can easily optimise your installation without wasting time by going to the site itself This manual describes the user interactions via a standard web browser Mozilla FF or MS IE and via the standard web browser of a Symbian smartphone SonyEricsson P910i Since the web server is based on accepted internet standards HTML any web browser complying with these standards should work accordingly Testing however has been limited to these programs Since it is intended for a standard user working on a ready configured installation the User Manual does no
27. ser Access Level Us er X Service System Maintenance X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X Sauter Systems o EYW300 novaWeb Configuration Login NV User Access Level Main Pages Actions Data Guest Us Service System Pages points er Maintenance S 4 Adding events X X X AS Display X X X X History Changing i i setpoints SP KN i Settin Alarms Changing X X gs recipients Changing X X schedules Data Display X X X Acquisition Display and X X X download values Changing X X recipients oystem Changing X X main system name tenance download HTML download versions upgrade re start stop re boot the system Time Selecting X X network clock Setting time X X manually Values Save and restore X X settings backup functions 7001056003 A Sauter Systems 33 EYW300 novaWeb Configuration ecco NU Login Devices Service devices only link X Perform memory clean preferred view select AS Login Modifying user X and passwords Network Modifying X network settings Language Selecting X language for HTML pages 34 7001056003 A Sauter Systems o EYW300 novaWeb Configuration Language selection 4 10 Language selection Depending on the language specification file lang csv it is possible to select between four different languages Alarm Data acquisition System maintenance Clock Val
28. set and load stored profile number n Comments control Enable XON XOFF software local flow control Enable RTS CTS hardware local flow control Enable XON XOFF software local flow control Select dial up mode Select asynchronous non EC mode the same as amp Q0 U S Canada pulse dialling 3996 make 6196 break ratio U K Hong Kong pulse dialling 3396 make 67 break ratio Asynchronous non EC mode No data buffering ASB disabled Select V 42 EC operation requires flow control Asynchronous mode with ASB requires flow control Select alternate EC protocol MNP Conditional data compression V 42bis yes MNP5 no Always on default Follows EIA specification active following carrier tone and until carrier is lost Model specific self test on some modems Enable V 32 TCM Disable V 32 TCM View oft stored configuration profile settings or ATI4 In NVRAM amp WO amp W1 etc for multiple profiles some settings cannot be stored These often do not show on amp V or ATIA Load profile O default Load profile 1 Note that all items after the amp Z on the command line are ignored Sauter Systems o EYW300 novaWeb Configuration Abbreviations and terminology NV 15 Abbreviations and terminology Activex Microsoft technology for software components which can be used by other programs AS Automation stations or controllers are autonomous automation devices for the control of heat
29. t IP address for the device on the LAN and the associated port for communication should be entered in the table in the input field for the firewall settings 7001056003 A Sauter Systems o EYW300 novaWeb Configuration TCP IP connections NV 7 3 2 ADSL Regarding the configuration of the network settings page this is identical to a WAN setting In the easiest case you get a static IP address as well as a DNS name which you specify in the network settings page If you use dynamic IP addresses this IP address has to be forwarded to a dynamic host name service which updates its DNS records assignment of host names to IP addresses This forwarding of the correct IP address must be handled via the ADSL device ADSL router Ethernet driver and service ADSL connection Internet Fc TP ADSL Router Modem nova291 Serial driver B12017 7001056003 A Sauter Systems 25 SF 26 EYW300 novaWeb Configuration 56500 TCP IP connections 7 3 3 Modem It is also possible to use a dial up dial in connection instead of a WAN If novaWeb sends out any messages alarms or DAQ it uses the dial up connection to forward this message to an SMTP e mail server usually on the internet When you want to connect to novaWeb you open a dial in connection usually direct modem to modem Ethernet driver and service connection Power LO CO I SO oe Modem nova291 TP RS232 Pe
30. t describe any configuration or programming issues For these please refer to the appropriate manual see also novaWeb documentation 7001056003 A Sauter Systems 5 EYW300 novaWeb Configuration ecco NZ Introduction 6 7001056003 A Sauter Systems o EYW300 novaWeb Configuration novaWeb documentation NV 2 novaWeb documentation According to the needs of the different users the documentation for novaWeb has been split up into several manuals Order Title Target Required Content Number Audience User Level 7001049 User Manual End User Guest or User Standard user operations such as e Connecting to the plant e Visualisation e E mail reception 7001057 Quick Start Project or Any Basic connection set up Guide Programming e Power supply Engineer novaNet amp Ethernet 7001056 Configuration Project Engineer System Connections Manual Maintenance e TCP IP e Dial up Advanced features e Firewall Settings e Dynamic DNS e E mail settings 7001050 Programming Programming Service Programming Manda Tonen e Content of HTML Case FBD and CASE Engine dd e Card code rules e House address structure e Extensions Customisation e Icons menus schematics etc 7001056003 A Sauter Systems 7 EYW300 novaWeb Configuration ecco NV novaWeb documentation On top of these manuals several other sources of information are available via the Sauter intranet e Product Data Sheet PDS e Product Information PI e
31. ts of the AS Whenever novaWeb discovers a new house address it will add this data point to the data point database However it will not delete data points since it would also lose the historic data connected to the data point even if the data point is only temporarily unavailable The garbage collection occurs every night the exact time depends on the AS address and after each complete download from the FBD however it can also be executed manually from CASE HWC or within the novaWeb Please be careful with the option to do a garbage collection for all ASs address 32000 on a large novaNet This could lead to a rather long subscription time especially when working simultaneously with further visualisation systems 7001056003 A Sauter Systems o EYW300 novaWeb Configuration novaNet connection NZ 6 1 3 AS selection If only a few automation stations e g out of a large novaNet need to be treated it is possible to specify which AS is to be visualised Select the Settings menu item in the left frame and then choose the Devices item from the sub menu in the main frame to go to the following display on the screen Alarm Data acquisition System maintenance Clock Values Devices Login Network Language Settings Devices Garbage collection q Start Choose station number 32000 for all Preferred view Auto Iv t AS selection 16 17 18 66 68 1024 Enter station number between 0 and 31744 Intervals are wri
32. tten as nn nn Separate stations and intervals with comma Leave empty to use all AS Ex 11 22 1001 1019 1033 In the AS Selection input box enter a station number between 0 and 31744 Intervals are written as nn nn Separate the stations and the intervals with commas Leave empty if you wish to use all automation stations e g 11 22 1001 1019 1033 Only the first 32 ASs of the selection will be treated So only the ASs O to 31 will be visualised if you specify AS 0 100 201 202 7001056003 A Sauter Systems 17 EYW300 novaWeb Configuration ecco NU novaNet connection 6 1 4 Preferred view There is a choice of views available since version 2 8 1 e The classic optimised view which is derived from the house addresses and their extensions name standard e The plant view is derived from the house address structure HA structure e The station view shows the addresses sorted according to which station they are assigned AS view e In addition the optimum view can be chosen automatically Auto If so checks are carried out in the following order If an application module is set MFA 63 DW 20 is O or 255 the plant view is derived from the house address structure HA structure If this is not the case the name standard is checked next If the planning is done according to the name standard if e g sp setpoint and ms main sensor of a data point are available this view is used lf neither house address structure nor
33. ues Devices Login Network Language Language English Svenska Deutsch O Francais Suomi To view the page for the language settings first select the Settings menu item in the left frame and then select the Language menu item in the main frame If your preferred language is not included please check with your local support for the availability of a customised version After switching the language some frames have to be reloaded manually Some buttons will appear properly only after novaWeb has been rebooted 7001056003 A Sauter Systems 35 4 36 7001056003 A EYW300 novaWeb Configuration 56500 Language selection Sauter Systems o EYW300 novaWeb Configuration Software update NV 11 Software update Call up the Settings link in the navigation window then the System maintenance link in the main window Download Versions upgrade Now you can download the latest software version for the novaWeb Contact your local customer service to obtain the file representing the latest software version 7001056003 A Sauter Systems 37 EYW300 novaWeb Configuration 56500 NZ Software update 38 7001056003 A Sauter Systems o EYW300 novaWeb Configuration Back up 12 Back up 12 1 Create a back up e Inthe Values tab click Back up settings e The File download menu then opens e Click Save in the File download menu Alarm Data acquisition System maintenance Clock Value
34. use a Unified Messaging Provider such as www ecall ch or teammessage de Another possibility is to use a GSM Service Provider such as Swisscom or Vodafone Most mobile phones automatically allow you to send and receive SMS messages If the Short Message Service SMS is not already programmed on your mobile phone then you usually need to enter and store the number of the service provider e g the Swisscom Mobile SMS exchange 41 79 499 90 00 To find out how this functions with your particular mobile phone please consult the user manual applicable to your model 8 5 E mail to WAP e mail to WAP gateways With certain e mail providers such as arcor yahoo web de freenet de or epost it is possible to access your e mail account via a WAP page Other gateway services like ZWAP www zwap de allow for provider independent WAP access to POP3 e mail accounts This could be useful if your mobile phone cannot access a normal e mail POP3 or IMAP account 7001056003 A Sauter Systems o EYW300 novaWeb Configuration Login NV 9 Login Within the login settings page you can specify the passwords for the different user levels To reach this page first call up the Settings menu item in the left frame and then select the Log In menu item in the main frame You see the following page Benutzerlevel Passwort Gast Login Erlauben Iw Service v service Osauter Benutzer user sauter x System Wartung m ml sauter

Download Pdf Manuals

image

Related Search

Related Contents

Samsung SMART CAMERA WB250F Bruksanvisning      Omixon Target User Manual  Produttiva Tecno  Dural Aqua-Fil - Euclid Chemical    Whirlpool RF396PXV User's Manual  Hama Bamboo  Manual  

Copyright © All rights reserved.
Failed to retrieve file