Home

PEFT 4010 Immunity Test Solution EFT/Burst and ESD

image

Contents

1. This makes the system compatible with reproducibility requirements in the approval process Instrument calibration information is stored internally a valuable aid to maintaining QA An adapter is used to mount the PEFT 4010 vertically maintaining easy access to the instrument front panel and a good ground plane connection while freeing the test area for larger EUTs A printer connected to the Centronix interface delivers ESD and EFT printouts for quality purposes which include date a time equipment setup ESD amp EFT external event parameters as detected by the PEFT 4010 EUT fail input Integration into our WinFEAT amp R and WinPATS remote control software packages together with other EMC simulators increases the power and flexibility of this system still further PRODUCT DEVELOPM ENT PEFT 4010 mainframe can deliver EFT impulses in different formats including a IEC pulse distribution m continuous impulses m random pulse distribution a real burst with constant amplitude m real burst with changing amplitude and frequency EFT s are injected using the integrated single phase CDN capacitive coupling clamp external three phase CDN or direct into electronic circuits using the electric and magnetic field generation probes The following parameter can be programmed to perform variations a test voltage a Spike frequency a syncronisation angle all the above plus polarity High para
2. 0600 e e SYSTEM ACCESSORIES Fibre optic interface used to connect the PESD PESD 1600 s 1600 with PEFT 4010 mainframe Remote A remote control panel attached to the PEFT 4010 mainframe Used to start stop or load tests or programs from the PEFT 4010 memory Vertical operation stand enables PEFT 4010 to be VOS used on a floor level ground plane Additional high voltage circuit board makes burst Real Burst modes Real 5 kHz and Real 100 kHz VTM 8000 Multipliers the PEFT 4010 output by two VTM 8000 E and H Field generation probe set can be used to Field Probes find electromagneticaly sensitive areas in a test object This set comprises 2 probes for the detection of electric and magnetic fields Scan EM FP EFT 32 1 is a fully automatic three phase 32A CDN s CDN Coupling path selection is direct from the PEFT 4010 front panel controls FP EFT 100M isa manual three phase CDN for operation up to 100A Both CDNs can be used on 690V power supplies IP4A is a capacitive coupling clamp for superposition of bursts on data lines in Coupling clamp accordance with IEC 61000 4 4 Ordering Information PEFT 4010 including all cables user manual and calibration certificate Accessories PESD 1600 ESD generator PESD 1600 Remote Control RS 232 converter with fiber optic link VOS Stand for vertical operation IP4A capacitive coupling clamp FP EFT 32 1 3 phase automatic coupling decouplin
3. Al Advanced Test Equipment Rentals ied 198 gt WWW atecorp com 800 404 ATEC 2832 WHEN QUALITY IS AN ISSUE THE CHOICE IS HAEFELY EMC r ml PEFT 4010 IMMUNITY TEST SOLUTION Al EFT BURST AND ESD HAEFELY 77 PEFT 4010 PEFT 4010 IMMUNITY TEST SYSTEM THE TEST SOLUTION FOR EMC TESTS ESD according to IEC 61000 4 2 EN 61000 4 2 EFT according to IEC 61000 4 4 EN 61000 4 4 Household Industrial Telecommunication M edical and many more applications Electrostatic charges are created by bringing dissimilar insulation materials together and then parting them Walking over an insulated floor is a typical example The resultant discharge ESD is a high frequency field which can cause failure in electronic circuits Bursts or EFT s Electrical fast transients are caused by operation of electro mechanical switches motors and distribution switch gear connected to the power distribution network A typical burst consists of a large number of recurring impulses at high frequency for a short time The impulse distribution for an opening switch is of decreasing frequency with increasing amplitude COMBINED EFT and ESD TESTING PEFT 4010 contains all the features expected from a top quality EFT generator plus the ability to con trol and document ESD testing using the Haefely PESD 1600 A fibre optic link connects PEFT 4010 mainframe with PESD 1600 Separate menus for EFT and ESD
4. g network FP EFT 100M 3 phase manual coupling decoupling network Easy Control remote unit Real Burst has to be mounted in factory VTM 8000 double output voltage to 8 kV Scan EM near field probe set Field Probes near field injection probes IEEE 488 GPIB Interface has to be mounted in factory OPTICAL DEC 95 RS232 Optical link Winpats Software WinFEAT amp R Software Adaptor Verification 50 Q Attenuator 54 dB 1 kQ Attenuator 60 dB Ordering No 249601 249330 249667 249735 249130 249253 249586 249602 249734 249604 249607 249608 249556 249689 249309 249970 249603 249549 249544 Worldwide Headquarters Haefely Test AG Business Unit EMC Bernstrasse 90 PO Box CH 8953 Dietikon Zurich Switzerland Phone 41 61 373 41 11 Fax 41 61 373 45 99 e mail EM Csales haefely com North American Office Haefely Test Inc 1308 Devils Reach Road VA 22192 Woodbridge USA Phone 1 703 494 1900 Fax 1 703 494 4597 e mail ReveszHTU aol com ae F111 52 Subject to change without prior notice 09 00 C HAEFELY
5. meter resolution helps to find exact failure levels A 2 MHz spike frequency exceeds the requirements of all current standards but reflects reality Higher test levels up to 8 kV can be achieved An expanded mode enables testing beyond normal Instrument limits The above points help raise overall product quality and reduce the incidence of products failing at the approval stage DIAGNOSTIC TESTING PEFT 4010 system can be used for diagnostic or characterisation tests using a Electrical and Magnetic probes on the HV output to generate a broadband field PESD 1600 ESD generator parameter changes on ESD gun are transfered to the PEFT 4010 and added to a test report Manually adjustable parameters on EFT generator The up down keys are used to change the follow ing parameters in real time once a test has started a test voltage a Spike frequency burst period a burst duration a synchronisation angle sSe eoe o gt y B d TECHNICAL SPECIFICATIONS PEFT 4010 Waveshape 50 Q Waveshape 1 kO Voltage range Spike frequency Burst duration Burst repetition Polarity Impulses per burst Impulses per second Output type Single phase CDN Maximum AC voltage Maximum AC current Maximum DC voltage Maximum DC current Frequency range Coupling attenuation Decoupling attenuation PESD 1600 5 50 ns 30 5 35 to 150 ns 0 10 4 5 kV 1 Hz to 2 MHz 0 01 to 999 ms 0 1 to 400 Hz or 2 5 ms to 10 s
6. or 1 to 500 period Positive Negative Alt 1000 max 12000 max coaxial 50 Q 250 V 16 A 110 V 16 A 1 to 100 MHz lt 2dB gt 20dB refer to brochure E111 59 INTERFACING EUT fail input Connect pass fail detection hardware to this BNC input and the EUT condition as determined by specific EUT supervision hardware is added to the database of test information and finally the log file EUT condition can also be used to determine the test course Control unit Internal memory M anual changes 18 tests and programs Voltage phase spike when test is frequency burst duration running burst period coupling path Synchronisation 162 3 40 50 60 and 400 Hz Sync input Burst synchronisation with external signal Automatic manual external fixed random real continuous Logic low to trigger Centronix to control 3 phase CDNs to control ESD generator RS 232 and GPIB IEEE 488 Safety circuit warning lamp Impulse trigger Spike distribution EUT failed input Printer interface P90 extension PESD remote Remote interface Safety Simulator design Dimensions 500 x 130 x 445 mm Weight approx 15 kg Power supply 85 264 V 50 60 Hz M anufacturing ISO 9001 EMC CE mark Safety IEC 1010 Trigger Input External signals can be used to trigger impulse generation to a particular event Synchronisation input Impulses can be synchronised to any external cyclic signal with a high degree of accuracy 4
7. tests are included in the PEFT 4010 plus the ability to read parameters from the ESD generator changed by the user once a test has been started THE HAEFELY EMC PEFT 4010 UNIT IS A STAND ALONE EFT AND ESD TEST SYSTEM FOR approval testing product development post design diagnostics PEFT 4010 mainframe contains a high performance EFT generator single phase mains coupler and control functions for the PESD 1600 ElectroStatic Discharge ESD generator The test system can be expanded to include a hand held remote control unit computer control from WinPATS and WinFEAT amp R software a 3 phase CDN s up to 100A Capacitive coupling clamp a 8 kV test level a field detection probes immunity and emission probes EASY FRONT PANEL OPERATION The BOOSTER START function enables Tests or complete Programs to be started with a minimum number of keystrokes The front panel layout and software structure are both intuitive and powerful The information key opens up a whole menu structure dedicated to calibration and service information so for example the next due calibration date can be programmed to prompt the operator PRODUCT APPROVAL PEFT 4010 test system can be used together with the remote control PESD 1600 as an automatic test system to fulfill current and future EFT ESD approval requirements Test programs for both EFT and ESD can be entered from the PEFT 4010 front panel and stored in one of the memory locations