Home
Arena Hazer™ Snapshot
Contents
1. 5 2 INTRODUCTION 6 FEATURES 6 DMX CHANNEL SUMMARY 6 PRODUCT OVERVIEW 6 PRODUCT OVERVIEW CONTINUED 7 3 SETUP 8 FUSE REPLACEMENT 8 FIXTURE LINKING 8 Data Cabling
2. 8 DMX Data Cable 8 Cable Connectors 9 3 Pin to 5 Pin Conversion Chart 9 SETTING UP A DMX SERIAL DATA LINK 9 4 OPERATING INSTRUCTIONS 10 OPERATION 10 Stand Alone Mode with Timer Remote 10 Stand Alone Mode without Timer Remote 10 DMX Mode 10 DMX CHANNEL VALUES 10 SETTING THE STAR
3. 77 lbs 35 kg Tank capacity 1 4 qt 1 3 L POWER Fixed voltage 110V 60 Hz or 230V 50 Hz Power consumption 752W 6 44A at 120V Max Inrush power 752W 6 44A at 120V Power factor 0 97 PERFORMANCE Output 20 000 cfm haze Heater 600W THERMAL Maximum ambient temperature 104 F 40 C FUSE Hazer 20mm Glass 7A 250V Slow Blow Internal control panel 20mm Glass 7A 250V Slow Blow CONTROL amp PR
4. 1 3 4 5 6 7 8 9 ON OFF 1 2 4 8 16 32 64 128 256 1 3 4 5 6 7 8 9 ON OFF 1 2 4 8 16 32 64 128 256 1 3 4 5 6 7 8 9 ON OFF 1 2 4 8 16 32 64 128 256 1 3 4 5 6 7 8 9 ON OFF 1 2 4 8 16 32 64 128 256 1 2 3 4 5 6 7 8 9 ON OFF 1 2 4 8 16 32 64 128 256 Address 24 Switch 5 16 Switch 4 8 Total 24 1 2 3 4 5 6 7 8 9 ON OFF 1 2 4 8 16 32 64 128 256 1 2 3 4 5 6 7 8 9 ON OFF 1 2 4 8 16 32 64 128 256 1 2 3 4 5 6 7 8 9 ON OFF 1 2 4 8 16 32 64 128 256 1 2 3 4 5 6 7 8 9 ON OFF 1 2 4 8 16 32 64 128 256 1 2 3 4 5 6 7 8 9 ON OFF 1 2 4 8 16 32 64 128 256 1 2 3 4 5 6 7 8 9 ON OFF 1 2 4 8 16 32 64 128 256 Resolving address using simple math Address 233 233 128 105 Turn ON Dip 8 105 64 41 Turn ON Dip 7 41 32 9 Turn ON Dip 6 9 8 1 Turn ON Dip 4 1 1 0 Turn ON Dip 1 DIPSWITCH DMX VALUE 1 2 3 4 5 6 7 8 9 1 2 4 8 16 32 64 128 256 Arena Hazer User Manual 11 2008 11 07 14 01 DMX QUICK REFERENCE CHART DMX Address Quick Reference Chart Dip Switch Posit
5. connected to device Stand alone mode All Chauvet lighting fixtures featuring stand alone functions do not require additional settings simply power the fixture and it will automatically enter into this mode If you still have a problem after trying the above solutions please contact CHAUVET Technical Support at the location on the next page Arena Hazer User Manual 13 2008 11 07 14 01 Technical Support Address Service Dept 3000 N 29th Ct Hollywood FL 33020 U S A Support Email tech chauvetlighting com Telephone 954 929 1115 Press 4 Fax 954 929 5560 Attention Service Website http www chauvetlighting com 5 APPENDIX DMX Primer There are 512 channels in a DMX 512 connection Channels may be assigned in any manner A fixture capable of receiving DMX 512 will require one or a number of sequential channels The user must assign a starting address on the fixture that indicates the first channel reserved in the controller There are many different types of DMX controllable fixtures and they all may vary in the total number of channels required Choosing a start address should be planned in advance Channels should never overlap If they do this will result in erratic operation of the fixtures whose starting address is set incorrectly You can however control multiple fixtures of the same type using the same starting address as long as the intended result is that of unison movement or operation In ot
6. voltage applied All fixtures must be connected to circuits with a suitable Earth Ground Contact Us World Wide General Information Chauvet Lighting 3000 North 29 th Court Hollywood FL 33020 voice 954 929 1115 fax 954 929 5560 toll free 800 762 1084 Technical Support Chauvet Lighting 3000 North 29 th Court Hollywood FL 33020 voice 954 929 1115 Press 4 fax 954 929 5560 Attention Service World Wide Web www chauvetlighting com Arena Hazer User Manual 3 2008 11 07 14 01 Safety Instructions Please read these instructions carefully which includes important information about the installation usage and maintenance of this product Please keep this User Guide for future consultation If you sell the unit to another user be sure that they also receive this instruction booklet Always make sure that you are connecting to the proper voltage and that the line voltage you are connecting to is not higher than that stated on the decal or rear panel of the fixture This product is intended for indoor use only To prevent risk of fire or shock do not expose unit to rain or moisture Make sure there are no flammable materials close to the unit while operating The unit must be installed in a location with adequate ventilation at least 20in 50cm from adjacent surfaces Be sure that no ventilation slots are blocked Always disconnect from power source before servicing or replacing lamp o
7. 272 304 336 368 400 432 464 496 1 0 0 0 1 17 49 81 113 145 177 209 241 273 305 337 369 401 433 465 497 0 1 0 0 1 18 50 82 114 146 178 210 242 274 306 338 370 402 434 466 498 1 1 0 0 1 19 51 83 115 147 179 211 243 275 307 339 371 403 435 467 499 0 0 1 0 1 20 52 84 116 148 180 212 244 276 308 340 372 404 436 468 500 1 0 1 0 1 21 53 85 117 149 181 213 245 277 309 341 373 405 437 469 501 0 1 1 0 1 22 54 86 118 150 182 214 246 278 310 342 374 406 438 470 502 1 1 1 0 1 23 55 87 119 151 183 215 247 279 311 343 375 407 439 471 503 0 0 0 1 1 24 56 88 120 152 184 216 248 280 312 344 376 408 440 472 504 1 0 0 1 1 25 57 89 121 153 185 217 249 281 313 345 377 409 441 473 505 0 1 0 1 1 26 58 90 122 154 186 218 250 282 314 346 378 410 442 474 506 1 1 0 1 1 27 59 91 123 155 187 219 251 283 315 347 379 411 443 475 507 0 0 1 1 1 28 60 92 124 156 188 220 252 284 316 348 380 412 444 476 508 1 0 1 1 1 29 61 93 125 157 189 221 253 285 317 349 381 413 445 477 509 0 1 1 1 1 30 62 94 126 158 190 222 254 286 318 350 382 414 446 478 510 1 1 1 1 1 31 63 95 127 159 191 223 255 287 319 351 383 415 447 479 511 Dip Switch Position DMX Address Arena Hazer User Manual 12 2008 11 07 14 01 General Troubleshooting Symptom Solution s Applies to Lights Foggers amp Snow Controllers Dimmers amp Chaser Auto shut off Check fan thermal switch reset Beam is very dim or not bright Clean optical system or replace lamp C
8. Chauvet 3000 N 29th Ct Hollywood FL 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com Arena Hazer Snapshot OK on Dimmer Outdoor OK Sound Activated DMX512 Master Slave 115V 230V Switch Replaceable Fuse User Serviceable Duty Cycle USER MANUAL TABLE OF CONTENTS 1 BEFORE YOU BEGIN 3 WHAT IS INCLUDED 3 UNPACKING INSTRUCTIONS 3 AC POWER 3 CONTACT US 3 SAFETY INSTRUCTIONS 4 MAINTENANCE 5 STORAGE
9. OGRAMMING Data input locking 3 pin XLR male socket Data output locking 3 pin XLR female socket Data pin configuration pin 1 shield pin 2 pin 3 Protocols DMX 512 USITT DMX Channels 2 or 3 ORDERING INFORMATION Arena Hazer Arena Hazer Fog Fluid 1 gallon FJU WARRANTY INFORMATION Warranty 2 year limited warranty
10. TING ADDRESS 11 DMX Quick Reference Chart 12 GENERAL TROUBLESHOOTING 13 TECHNICAL SUPPORT 14 5 APPENDIX 14 DMX PRIMER 14 GENERAL MAINTENANCE 15 RETURNS PROCEDURE 15 CLAIMS 15 TECHNICAL SPECIFICATIONS 16 Arena Haze
11. and replace with exact same type fuse Insert the fuse holder back in its place and reconnect power Remove using a flat head screwdriver The fuse is located inside this compartment Remove using a flat head screwdriver With a flat head screwdriver unscrew the fuse holder from its housing Remove the damaged fuse from its holder and replace with exact same type fuse Screw the fuse holder back in its place and reconnect power FUSE Fixture Linking You will need a serial data link to run light shows of one or more fixtures using a DMX 512 controller or to run synchronized shows on two or more fixtures set to a master slave operating mode The combined number of channels required by all the fixtures on a serial data link determines the number of fixtures the data link can support Important Fixtures on a serial data link must be daisy chained in one single line To comply with the EIA 485 standard no more than 32 devices should be connected on one data link Connecting more than 32 fixtures on one serial data link without the use of a DMX optically isolated splitter may result in deterioration of the digital DMX signal Maximum recommended serial data link distance 500 meters 1640 ft Maximum recommended number of fixtures on a serial data link 32 fixtures Data Cabling To link fixtures together you must obtain data cables You can purchase CHAUVET certified DMX cables directly from a dealer di
12. d with a mild solution of glass cleaner or Isopropyl Alcohol and a soft lint free cotton cloth or lens tissue Apply solution to the cloth or tissue and drag dirt and grime to the outside of the lens Gently polish optical surfaces until they are free of haze and lint The cleaning of internal and external optical lenses and or mirrors must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit s optics Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days Returns Procedure Returned merchandise must be sent prepaid and in the original packing call tags will not be issued Package must be clearly labeled with a Return Merchandise Authorization Number RMA Products returned without an RMA will be refused Call CHAUVET and request RMA prior to shipping the fixture Be prepared to provide the model number serial number and a brief description of the cause for the return Be sure to properly pack fixture any shipping damage resulting from inadequate packaging is the customer s responsibility CHAUVET reserves the right to use its own discretion to repair or replace product s As a suggestion proper UPS pack
13. en proceed to connect from the output as stated above to the input of the following fixture and so on CHAUVET Certified DMX Data Cables Order Code Description DMX1 5 DMX Cable 1 5m 4 9ft DMX4 5 DMX Cable 4 5m 14 8ft DMX10 DMX Cable 10m 32 8ft COMMON DMX DMX INPUT OUTPUT 1 3 2 1 3 2 1 3 2 Resistance 120 ohm 1 4w between pin 2 DMX and pin 3 DMX of the last fixture Termination reduces signal errors To avoid signal transmission problems and interference it is always advisable to connect a DMX signal terminator DMX connector configuration 4 OPERATING INSTRUCTIONS Operation Stand Alone Mode with Timer Remote This mode allows a single unit to run with the timer remote and without a DMX controller 1 Set the DMX address on the hazer to 000 2 Adjust the fan speed haze output and timer interval using the timer remote Note The timer remote does not control the output of the blower Use the knob on the inner control panel by the dipswitches to adjust the blower speed Stand Alone Mode without Timer Remote This mode allows a single unit to run without the timer remote and without a DMX controller 1 Set the DMX address of the hazer to 6XX where the first X represents the desired fog output and the second X represents the desired fan speed 0 is off and 9 is high 2 Adjust the speed of the blower by turning the knob on the inner control panel by
14. heck 220 110v switch for proper setting Breaker Fuse keeps blowing Check total load placed on device Chase is too slow Check users manual for speed adjustment Device has no power Check for power on Mains Check device s fuse internal and or external Fixture is not responding Check DMX Dip switch settings for correct addressing Check DMX cables Check polarity switch settings Fixture is on but there is no movement to the audio Make sure you have the correct audio mode on the control switches If audio provided via jack make sure a live audio signal exists Adjust sound sensitivity knob Lamps cuts off sporadically Possible bad lamp or fixture is overheating Lamp may be at end of its life Light will not come on after power failure Some discharge lamps require a cooling off period before the electronics in the fixture can kick start it again wait 5 to 10 minutes before powering up Loss of signal Use only DMX cables Install terminator Note Keep DMX cables separated from power cables or black lights Moves slow Check 220 110v switch for proper setting No flash Re install bulb may have shifted in shipping No laser output Bounce mirror motor may have shifted during shipping readjust No light output Check slip ring amp brushes for contact Install bulb Call service technician Relay will not work Check reset switch Check cable connections Remote does not work Make sure connector is firmly
15. her words the fixtures will be slaved together and all respond exactly the same DMX fixtures are designed to receive data through a serial Daisy Chain A Daisy Chain connection is where the DATA OUT of one fixture connects to the DATA IN of the next fixture The order in which the fixtures are connected is not important and has no effect on how a controller communicates to each fixture Use an order that provides for the easiest and most direct cabling Connect fixtures using shielded two conductor twisted pair cable with three pin XLR male to female connectors The shield connection is pin 1 while pin 2 is Data Negative S and pin 3 is Data positive S CHAUVET carries 3 pin XLR DMX compliant cables DMX 10 33 DMX 4 5 15 and DMX 1 5 5 Arena Hazer User Manual 14 2008 11 07 14 01 General Maintenance To maintain optimum performance and minimize wear fixtures should be cleaned frequently Usage and environment are contributing factors in determining frequency As a general rule fixtures should be cleaned at least twice a month Dust build up reduces light output performance and can cause overheating This can lead to reduced lamp life and increased mechanical wear Be sure to power off fixture before conducting maintenance Unplug fixture from power Use a vacuum or air compressor and a soft brush to remove dust collected on external vents and internal components Clean all glass when the fixture is col
16. ing or double boxing is always a safe method to use Note If you are given an RMA please include the following information on a piece of paper inside the box 1 Your name 2 Your address 3 Your phone number 4 The RMA 5 A brief description of the symptoms Claims Damage incurred in shipping is the responsibility of the shipper therefore the damage must be reported to the carrier upon receipt of merchandise It is the customer s responsibility to notify and submit claims with the shipper in the event that a fixture is damaged due to shipping Any other claim for items such as missing component part damage not related to shipping and concealed damage must be made within seven 7 days of receiving merchandise Arena Hazer User Manual 15 2008 11 07 14 01 Arena Hazer User Manual 16 2008 11 07 14 01 Technical Specifications WEIGHT amp DIMENSIONS Length 20 9 in 532 mm Width 18 1 in 460 mm Height 17 in 432 mm Weight
17. ion DMX DIP SWITCH SET 9 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 0 OFF 8 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 1 ON 7 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 X OFF or ON 6 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 1 2 3 4 5 0 0 0 0 0 32 64 96 128 160 192 224 256 288 320 352 384 416 448 480 1 0 0 0 0 1 33 65 97 129 161 193 225 257 289 321 353 385 417 449 481 0 1 0 0 0 2 34 66 98 130 162 194 226 258 290 322 354 386 418 450 482 1 1 0 0 0 3 35 67 99 131 163 195 227 259 291 323 355 387 419 451 483 0 0 1 0 0 4 36 68 100 132 164 196 228 260 292 324 356 388 420 452 484 1 0 1 0 0 5 37 69 101 133 165 197 229 261 293 325 357 389 421 453 485 0 1 1 0 0 6 38 70 102 134 166 198 230 262 294 326 358 390 422 454 486 1 1 1 0 0 7 39 71 103 135 167 199 231 263 295 327 359 391 423 455 487 0 0 0 1 0 8 40 72 104 136 168 200 232 264 296 328 360 392 424 456 488 1 0 0 1 0 9 41 73 105 137 169 201 233 265 297 329 361 393 425 457 489 0 1 0 1 0 10 42 74 106 138 170 202 234 266 298 330 362 394 426 458 490 1 1 0 1 0 11 43 75 107 139 171 203 235 267 299 331 363 395 427 459 491 0 0 1 1 0 12 44 76 108 140 172 204 236 268 300 332 364 396 428 460 492 1 0 1 1 0 13 45 77 109 141 173 205 237 269 301 333 365 397 429 461 493 0 1 1 1 0 14 46 78 110 142 174 206 238 270 302 334 366 398 430 462 494 1 1 1 1 0 15 47 79 111 143 175 207 239 271 303 335 367 399 431 463 495 0 0 0 0 1 16 48 80 112 144 176 208 240
18. justable haze output via DMX wired remote or control panel on rear Adjustable fan speed via DMX or control panel on rear Adjustable blower speed via DMX or control panel on rear with variable angles Additional Features Road case included with easy refill system True continuous output 600 watt heater Output 20 000cfm haze 1 4 quart tank capacity Wired multi function remote included Water based hazer use only Chauvet Fog Fluid DMX Channel Summary CHANNEL FUNCTION 1 Haze 2 Fan 3 Blower Product Overview Squirrel cage blower LED fluid level indicator blinks when fluid is low Fluid tank access Haze output Carrying handle Arena Hazer User Manual 6 2008 11 07 14 01 Product Overview Continued Remote input DMX Address DMX Out Rear of hazer DMX In Power Switch Fan IEC Power Connector Inside flight case DMX In Power and DMX LED Red when power is on orange when receiving DMX Dipswitches Power Switch and Fan Speed Control Knob Hazer Power Cable Fuse IEC Power Connecto r Arena Hazer User Manual 7 2008 11 07 14 01 3 SETUP Disconnect the power cord before replacing a fuse and always replace with the same type fuse Fuse Replacement The fuse is located inside this compartment With a flat head screwdriver wedge the fuse holder out of its housing Remove the damaged fuse from its holder
19. r CAUTION Do not allow contact between the common and the fixture s chassis ground Grounding the common can cause a ground loop and your fixture may perform erratically Test cables with an ohm meter to verify correct polarity and to make sure the pins are not grounded or shorted to the shield or each other 3 PIN TO 5 PIN CONVERSION CHART 3 PIN TO 5 PIN CONVERSION CHART Note If you use a controller with a 5 pin DMX output connector you will need to use a 5 pin to 3 pin adapter CHAUVET Model No DMX5M or DMX5F The chart below details a proper cable conversion Note If you use a controller with a 5 pin DMX output connector you will need to use a 5 pin to 3 pin adapter CHAUVET Model No DMX5M or DMX5F The chart below details a proper cable conversion 3 PIN TO 5 PIN CONVERSION CHART 3 PIN TO 5 PIN CONVERSION CHART Conductor Conductor 3 Pin Female output 3 Pin Female output 5 Pin Male Input 5 Pin Male Input Ground Shield Pin 1 Pin 1 Data signal Pin 2 Pin 2 Data signal Pin 3 Pin 3 Do not use Do not use Do not use Do not use Setting up a DMX Serial Data Link 1 Connect the male 3 pin connector side of the DMX cable to the output female 3 pin connector of the controller 2 Connect the end of the cable coming from the controller which will have a female 3 pin connector to the input connector of the next fixture consisting of a male 3 pin connector 3 Th
20. r User Manual 2 2008 11 07 14 01 1 BEFORE YOU BEGIN What is included 1 x Arena Hazer Road Case and Blower Timer Remote Power Cord Warranty Card User Manual Unpacking Instructions Immediately upon receiving a fixture carefully unpack the carton check the contents to ensure that all parts are present and have been received in good condition Notify the shipper immediately and retain packing material for inspection if any parts appear damaged from shipping or the carton itself shows signs of mishandling Save the carton and all packing materials In the event that a fixture must be returned to the factory it is important that the fixture be returned in the original factory box and packing AC Power To determine the power requirements for a particular product see the label affixed to the back plate of the product or refer to the product s specifications chart A product s listed current rating is its average current draw under normal conditions All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel is used solely for a 0 to 100 switch Before applying power check that the source voltage matches the product s requirement Warning This product was made to operate at a fixed voltage There is no voltage select switch Verify that the voltage requirement for this fixture matches the line
21. r fuse and be sure to replace with same lamp source Maximum ambient temperature Ta is 95 F 35 C Do not operate fixture at temperatures higher than this In the event of a serious operating problem stop using the unit immediately Never try to repair the unit by yourself Repairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest authorized technical assistance center Always use the same type spare parts Make sure the power cord is never crimped or damaged Never disconnect the power cord by pulling or tugging on the cord Caution There are no user serviceable parts inside the unit Do not open the housing or attempt any repairs yourself In the unlikely event your unit may require service please contact CHAUVET at 954 929 1115 Caution You must only use Chauvet Fog fluid with this product Although this is a haze machine the haze is created using water based fog fluid If you use haze fluid then the consistency of the haze will not be correct and it may be potentially hazardous to the environment being used in Arena Hazer User Manual 4 2008 11 07 14 01 WARNING Note All fog machines are prone to clogging due to the thick consistency of fog liquid and the high temperature at which it vaporizes However a properly maintained fog machine should provide years of reliable use Cleaning your fog machine regularly will help reduce costly replacement and repair charge
22. s Maintenance Do not allow the fog liquid to become contaminated After every 40 hours of continuous operation it is recommended to run a cleaning solution composed of 80 distilled water and 20 distilled vinegar through the system to prevent the accumulation of particulate matter in the heating element The recommended cleaning regimen is as follows 1 Empty all fog liquid from the machine Add cleaning solution to tank Plug unit in and begin warm up 2 Run the unit in a well ventilated area until the tank is almost empty Do not allow the pump to run dry 3 Replace nozzle 4 Cleaning is now complete Refill with fog liquid Run the machine briefly to clear any cleaning solution from the pump and heater 5 Do not operate the fog machine without liquid at any time Storage 1 When storing run distilled water not tap water through the system as described in the cleaning regimen above This will help avoid any particles condensing inside the pump or heater 2 It is strongly recommended to test run the machine on a monthly basis in order to achieve its best fogging condition A test run consists of warming up the machine followed by a few minutes of emission After that follow Step 1 under Storage Arena Hazer User Manual 5 2008 11 07 14 01 2 INTRODUCTION Features 2 or 3 channel DMX 512 professional hazer Dual component system 2 channel DMX 512 professional hazer 1 channel DMX 512 squirrel cage blower Ad
23. sses so that the channels used do not overlap and note the start address selected for future reference If this is your first time addressing a fixture using the DMX 512 control protocol we suggest jumping to the Appendix Section and reading the heading DMX Primer It contains very useful information that will help you understand its use Set the start address using the group of DIP switches located usually on bottom of the fixture Each dip switch has an associated value Adding the value of each switch in the ON position will provide the start address Figuring out which switches to toggle ON given a specific start address can be accomplished by determining which switch values will add up to the address value and turning these switches on Do so by doing the following 1 Determine the largest value switch that is less than the start address Turn this switch on 2 Subtract the value of the switch you just turned on from the starting address number 3 Determine the largest value switch that is less than the remainder from the previous subtraction Turn this switch on 4 Subtract the value of the switch you just turned on from the remainder of the previous subtraction 5 Repeat steps three and four until you have a remainder of zero EXAMPLE STARTING ADDRESS Address 10 Switch 4 8 Switch 2 2 Total 10 1 3 4 5 6 7 8 9 ON OFF 1 2 4 8 16 32 64 128 256
24. stributor or construct your own cable If you choose to create your own cable please use data grade cables that can carry a high quality signal and are less prone to electromagnetic interference DMX DATA CABLE Use a Belden 9841 or equivalent cable which meets the specifications for EIA RS 485 applications Standard microphone cables cannot transmit DMX data reliably over long distances The cable will have the following characteristics 2 conductor twisted pair plus a shield Maximum capacitance between conductors 30 pF ft Maximum capacitance between conductor and shield 55 pF ft Maximum resistance of 20 ohms 1000 ft Nominal impedance 100 140 ohms Arena Hazer User Manual 8 2008 11 07 14 01 CABLE CONNECTORS CABLE CONNECTORS Cabling must have a male XLR connector on one end and a female XLR connector on the other end Cabling must have a male XLR connector on one end and a female XLR connector on the other end Arena Hazer User Manual 9 2008 11 07 14 01 This drawing provides a general illustration of the DMX Input Output panel of a lighting fixture Universal DMX Controller Continue the link CAUTION Do not allow contact between the common and the fixture s chassis ground Grounding the common can cause a ground loop and your fixture may perform erratically Test cables with an ohm meter to verify correct polarity and to make sure the pins are not grounded or shorted to the shield or each othe
25. the dipswitches DMX Mode This mode allows the unit to be controlled by any universal DMX controller If you are unfamiliar with DMX please read the DMX Primer on page 14 Note The blower has a DMX in but does not have a DMX out In order to properly connect this fixture to DMX you must have it be the end of the DMX link or use a DMX splitter Chauvet part number DMX 2X 1 Set the DMX address of the hazer to the desired value using the numeric controls on the hazer 2 Set the DMX address of the blower to the desired value using the dipswitches Note The blower and the hazer fan can be set to the same DMX address to reduce the channel count of the Arena Hazer from 3 to 2 DMX Channel Values CHANNEL VALUE FUNCTION 1 000 010 011 255 Haze No output Haze output low gt high 2 000 005 006 255 Fan Fan off Fan speed low gt high 3 000 005 006 255 Blower Blower off Blower speed low gt high Arena Hazer User Manual 10 2008 11 07 14 01 SETTING THE STARTING ADDRESS This DMX mode enables the use of a universal DMX controller device Each fixture requires a start address from 1 to 512 A fixture requiring one or more channels for control begins to read the data on the channel indicated by the start address For example a fixture that uses 6 DMX channels and was addressed to start on DMX channel 100 would read data from channels 100 101 102 103 104 and 105 Choose start addre