Home

English Jeohunter Basic User Manual

image

Contents

1. ww w The values stated above aren t values they are gathered by trying new metals As the dimensions of the metals increase there is an increase in the depth as seen in the ratios stated in the table If metals remain under the ground for a long time in pace of that time they establish a magnetic area and these magnetic areas radiates as if there are transmitters By this means the receiver of the research antenna ensures detection of the same target in 3 4 times deeper areas BATTERY AND CHARGER 16 8 V 3 3 A Rechargeable Lithium Polymer Battery Operating voltage 12 V 16 8 V 16 8 v 500 mA Lithium Polymer Battery Charger Input 000000 100 240 v 50 60 Hz 180 mA city mains 22 ACCESSORIES Condura Plastic totebag for the whole hardware Double zippered Condura plastic carriage bag Lithium Polymer Battery reinforced for deep search coil Optional Universal AC charger System box leather 100 240 Volt 50 and totebag Automotive charger Optional Warranty Period 2 Years Note Battery bags headphones and chargers are not covered by warranty 2 Fax 90 216 641 61 65 5 info makrodetector com WWW makrodetector com gt gt i
2. 3 Deep Search Coil 600x1000 mm and Carrying Case Optional This is the search coil system developed for deep exploration that can be carried by two persons There is a separate carrying case for this search coil This system can only operate in LCD mode When sensitivity is set to 60 it will be possible to carry out exploration easily without affecting from small metal pieces and without any ground setting 5 Batteries 14 8 V 4 Ampere Lithium Polymer rechargeable batteries Battery Operating Voltage Min 12 V Battery Operating Voltage Max 14 8 V Battery Current 4 Battery Life 4 6 hours 6 Battery Charger It is a device to charge 14 8 V 4 Ampere Lithium Polymer batteries Input AC 100 240 V 50 60 Hz 1A City mains Output DC 12 16 8 V 400 mA Charge duration 10 hours 7 Carrying Case It is a case used for transport and storing of the System box the 360x440 mm Search coil and accessories 8 Headphone It is the piece that maintains vocal communication between the detector and the operator Waterproof speaker on the electronic system is turned off when using the headphone to enable only the operator to hear the sound of the detector 11 ELECTRONIC SYSTEM UNIT GROUND The key that allows switching to Ground Setting mode in LCD system mode SETUP The key that allows switching to the Settings Menu DEPTH The key that enables the device to switch to diameter screen an
3. RESET lowers the search coil 3 5 cm parallel to the ground If the device receiving negative effects the operator lifts the detector and presses the button several times if the effect is positive the operator presses the button several times and presses reset button then lowers the search coil to 3 5 cm form the ground The procedure must be repeated until the ground effect is neutralized The device is ground balanced when you do not get to hear any signal when lowering the search coil for exploring After the effect is neutralized the operator raises the detector search coil 8 15 cm above the ground and switches to the explore mode by pressing the ACCEPT button Stabilizing the detector 8 15 cm from the ground will give you reliable search results 13 10 40 If there is no ground effect on the device there is no interaction on the bar that is indicated in the figure and Ground Setting 100 Completed expression is displayed In this case the device is ready for exploring and you may switch to explore mode by pressing the ACCEPT button In case there is ground effect onlthe device an interaction is observed in the GROUND ADJUST bars that are indicated in the figure To eliminate this effect press button for effect and press button for effect Press or buttons until this effect is eliminated and Ground Setting 100 Completed expres
4. a metal or a mineral source by reading the oscilloscope right 1 Target is a small metal and close to 5 Target is a large metal and deep surface Metal Target Surface Be Surface O 2 Target is a couple of small metals 6 Target is a large metal and deeper close to surface underground Surface gt Surface 5 3 Target is couple of small metals 7 Target is a cavity and very close to slightly deep surface Surface Surface at amp Metal Target 8 4 Target is a large metal and close to 8 Target is a cavity and deep surface Surface Metal Target Depth rf Surface 5 17 9 Target is a cavity and deeper 11 If the oscilloscope line draws a underground straight line close to center line it points that the ground is a high mineral soil So the ground balance needed to be recalibrated Surface Depth a 10 Target is a metal inside of a cavity or phe Depth If the signal line increases very sharp and decreases with same velocity there is no need to calculate depth Because this shows that the target is very close the surface Oscilloscope never draws a straight line while it receives signals from true target it always draws sinuous lines Oscilloscope line is closer the center line when the target is deep and line is away from the center line when the target is clos
5. depth during exploring Press the DEPTH key when in explore mode after the target is detected First the dimensions of the target should be determined in depth mode This operation is explained in detail with operator help menu To enter the help menu form a yellow frame around the HELP window by using and keys Press the ACCEPT button after forming this frame In this menu it is explained to the in detail how to determine the dimensions of the target To enter the determined width dimension place the yellow frame on Width by using and keys Press the ACCEPT button to convert the yellow frame to green 19 Commented by computing the ground effe target enwitonmental effect andthe distance of Lenght ot He Cr Enter the Width value by using keys Press the ACCEPT button after entering the width value and convert the frame into yellow To enter the determined length dimension place the yellow frame on Length by using and keys Press the ACCEPT button to convert the yellow frame to green Enter the Length value by using keys Press the ACCEPT button after entering the length value Press the SCAN button after this operation and pass over the target again and release the SCAN button After this operation the device presents an Analy
6. is electronic and very sensitive never assemble and operate before reading the user manual Do not start searching before making ground settings It will not be possible that the device operate correctly unless the ground setup is made Do not use any other detector or a device that emit magnetic waves within 10 m proximity of the device Prevent the device from abrupt movements and possible shock Do not expose the search coil to direct heat do not exert force during assembly and use The battery should be decently placed in its casing and care should be taken poles are not connected by a metal pieces Do not expose the battery to heat Charge the battery in room temperature Do not exert pressure on the LCD monitor Once a month discharge the battery by plugging it to detector and recharge again in case of enduring the battery life ACCESSORIES AND COMPONENTS 1 Electronic System Box and Case It is the part where the detector sockets headphone socket joystick feed socket and battery socket are located and where measurement results are evaluated and displayed on the LCD monitor There is a carrying apparatus for easy transport of this system 2 General Search Coil 360x440 mm It is the system that consists of the search coil for general purposes There are no LEDs on this system and operator follows the results on a LCD monitor located on the system box This system can only be used in LCD mode
7. Makro Detector ince 1996 COMPONE NMS 4 Electronic System 6 Assembly and Charging the Battery 7 Using tne LED MOJ Cusco soe 9 What is Ground Setting and How It Is 12 How Ground Setting 15 13 Performing Search with LCD System 15 Reading the 17 Ferrous Metal Elimination Function 18 Getting and Analysis Report by Analyzing the 19 Detection of Target 19 Recording and Examination Of 21 22 AC COSSON 22 23 PLEASE DO NOT START ASSEMBLING OR USING BEFORE READING THE WARNINGS SECTION WARNINGS Some metals that are buried under ground for a long time and rotten like sheet steel and tin lead galvanize etc May in some cases may give an impression as gold Position of metals under the ground influence perception of the device and may cause an effect as gold or precious metal Since the device
8. d carry out depth analysis RECORD The key that enables entry to recording screen in addition to recording the report in report analysis section RESET Resets all detector settings Default Settings in reference to recent settings whenever resetting is done s The minus key The plus key SCAN A key that enables analyzing a target when pressed passing over it ACCEPT The key that approves the related function and enable to switch to the previous menu ON OFF Switch The switch that is used for selecting between device turn off and system selection LCD The section that presents data to the operator in LCD system 6 ASSEMBLY AND CHARGING THE BATTERY 1 CHARGING THE BATTERY Remove the battery from the system box and connect to the charger When battery is being charged red LED will lights and when the charging is done green LED will lights If there is no battery attached to the charger or the attached battery is fully charged the green LED lights After charging disconnect the battery from the charger and place it into system box The charging period required for a fully depleted battery to be fully charged is 7 hours 2 ASSEMBLY Search coil is taken off the carrying case and telescopic extension tube is inserted piece Nr 1 into piece Nr 2 as shown in the diagram and tighten the sleeve The search coil is dismounted from the extension tube when packing in the carrying case Disman
9. d of the device in whatever mode is it in The current adjusted sensitivity level is displayed as on the screen Select the SENSITIVITY mode by pressing and keys as described above After this mode is selected press the ACCEPT button the sensitivity indicator bar will turn from yellow into green Adjust the sensitivity level by pressing and keys and press ACCEPT button The green indicator bar turns back into yellow Now the sensitivity level is adjusted as you desired and you can switch to the previous mode by pressing SETUP button Adjustment of IRON Mode SETUP button is pressed for switching the level of IRON mode of the device on and off in whatever mode is it in The current IRON mode is displayed as open or closed You may find more detailed information about the properties of this mode and how it is used in following sections Using the RESET Button When the device is in use some interference may occur due to the environment or unbalanced search coil movement These interferences start to show on the screen and cause the device to give a sound alarm Resetting can be done by pressing the RESET button on the system box By resetting the effects of interference are eliminated Resetting should not be done when the search coil is over the target This will cause loss of depth misinterpretation of received signal and the target become invisible to the device Re
10. e Ferrous Metal Elimination Function The device can enable to filter the worthless metals by the device and warn the operator if desired For this operation IRON mode should be off To switch off this mode press SETUP button when in explore or ground modes Select the IRON mode by pressing the key After selecting this mode press the ACCEPT button Place the frame that turns from yellow to into green on OFF and press the ACCEPT button again After this operation press SETUP button to switch to the previous mode Following this step the device will filter worthless metals To be able to detect worthless metals again this mode should be switched back to ON mode by repeating above mentioned operation 18 Getting and Analysis report by Analyzing the Target To get an analysis report by analyzing the detected target during exploration e Press the RESET button by removing the search coil off the target after the target is detected e Press and hold the SCAN button when passing over the target again slowly At that moment the device analyzes the target e Release the SCAN button after you pass overt the target After this operation the device presents the ANALYSIS REPORT to the operator Type of the metal magnitude of the target and the ratios of other environmental effects are received Detection of Target Depth For detecting target
11. e device to LCD System the commutator switch is adjusted to LCD After the device is switched on the operator makes the desired language selection by using and keys and press ACCEPT button to finalize the language selection When the device is on the LCD mode the screen system is enabled and the device detects the installed search coil and prepares for that search coil If no search coil is installed on the device a warning is displayed on the screen Coil and System Error Warnings there is an error in the search coil or in the system SEARCH COIL FAULT or SYSTEM FAULT warning lights blink at the bottom of the screen and a sound alarm is heard to warn the operator after the device is switched on In this case the operator should switch off the device check the connectors and The Search Head Mounted to the Devi CAVITY METAL IRON VA LUAULE SCAROM HEAD FALLI OAVITY METAL IRON VALUAQNLE FALLI a witch on the device again If the warning persists authorized service should be called Checking Battery Charge Level The device switches to Ground Adjustment section after it detects the search coil At the bottom of this section there is an area that indicates battery status and the operator detects battery status by referring to this area If the battery is depleted or does not have adequate charge switch off the device and charge the batterie
12. he operator as CAVITY or METAL If the target is a CAVITY there is a raise on the CAVITY bar and decrease in the graph The GAVITY METAL IRON VALUARLE intensity of the CAVITY bar is indicated as on top depending on the magnitude of the effect of target 15 If the target is valuable metal there is a raise both on the METAL and VALUABLE that is expressed in depending on the magnitude of the effect The effect of metal can be monitored in the graph on top of the bars If the target is worthless metal there is a raise both on the METAL IRON that is expressed in depending on the magnitude of the effect When an alarm is received from the device over any point the device is taken away from the target and reset in an area where no signal is received and the search coil is passed over the same target again If there is increase in the CAVITY bar our target is a cavity If there is increase in the METAL and VALUABLE or IRON bar our target is a metal If required the RESET button is pressed and search coil is passed over the target once more This last operation is done to be sure about the result 16 READING THE OSCILLOSCOPE Oscilloscope draws plan view of an underground target It helps us to pre understanding the shape quantity and depth of the target Also it is a very important system that allows knowing that the source signal is
13. s installing the charger Adjustment of SOUND Level SETUP button is pressed for adjusting the level of sound of the device in whatever mode is it in The current adjusted sound level is displayed as on the screen Select the SOUND mode by pressing and keys as described above After this mode is selected press the ACCEPT button the sound indicator bar will turn from yellow into green Adjust the sound level by pressing and keys and press ACCEPT button The green indicator bar turns back into yellow Now the sound level is adjusted as you desired and you can switch to the previous mode by pressing SETUP button Adjusting LIGHT Level SETUP button is pressed for adjusting the level of light of the device in whatever mode is it in The current adjusted light level is displayed as on the screen Select the LIGHT mode by pressing and keys as described above After this mode is selected press the ACCEPT button the light indicator bar will turn from yellow into green Adjust the light level by pressing and keys and press ACCEPT button The green indicator bar turns back into yellow Now the light level is adjusted as you desired and you can switch to the previous mode by pressing SETUP button 10 Adjustment of SENSITIVITY Level SETUP button is pressed for adjusting the level of soun
14. setting procedure is carried out after the search coil is removed away from the target 11 WHAT IS GROUND SETTING AND HOW IT IS DONE In our country land formation and soil composition vary in relation to regions In some regions the composition may vary frequently Sand lime red earth with dense mineral content rocky formation etc These variations in soil composition mislead the detector and cause perception as metal or cavity Therefore first we have to launch the soil characteristics of the region to the detector s system Launching these data will block all misleading effects that may come up from the ground these will be perceived as misleading signals from the ground and thus eliminated Ground setting is one of the most important provisions of exploration Therefore the operator should be a keen observer and should be able to detect variations in the ground He has to observe soil compositions continuously to be able to make ground adjustment again in case misleading signals the device will perceive results from variations in soil composition Ground setting is made for the device to recognize the soil and not to be affected by it Thus the device is not affected from metal or cavity reflections of varying soil compositions If ground setting is not properly done it will cause loss of depth and minerals to be evaluated as metals or cavities Therefore ground settings should be made as correctly as possible Considering
15. sion is displayed Vivo a NONE uU l After pressing or buttons lift the search coil 40 cm above ground and press the RESET button and observe the ground effect by holding the search coil 3 5 cm above ground if ground effect persists try to eliminate this effect by pressing or buttons If we are not able to eliminate the ground effect decrease the sensitivity level one step and repeat the above defined operation After the ground effect is eliminated you may press the ACCEPT button and switch to Explore Mode 14 PERFORMING SEARCH WITH LCD SYSTEM After GROUND setting is completed ACCEPT button is pressed and switched to Explore Mode Hold the search coil 8 15 cm above and parallel to the ground You can explore by moving the search coil slowly with a right to left sweeping motion or by walking straight Try to detect a target by exploring this way When the device detects a metal or a cavity it gives a sound alarm and interaction occur on CAVITY METAL IRON and VALUABLE bars according to the power of the signal At the same time the effect of the target can be monitored on the graph above the bars Metal targets are indicated with upper projecting lines and cavity targets are indicated with lower projecting lines on this graph Ground effect that may be formed together with the target is also displayed on the display This ground effect is indicated to t
16. sis Report that indicates whether the target is METAL or CAVITY entered dimension values and environmental effects Press the ACCEPT button to leave this report Switched back to Depth mode and switched to explore mode by pressing the DEPTH button 20 Lenght Hidth 90 120 Width 90 Lenght 120 AMETER 0 X 120 cm Recording and Examination of Records The device can record the analysis reports as directed by the operator Press the RECORD button after the report is prepared and save the Analysis Report Press the ACCEPT button after you receive a message on the monitor that recording is completed To examine the records later enter the record menu by pressing the RECORD button when in explore mode and you can examine the records by pressing and keys Press the ACCEPT button when in the record menu On top of the monitor there are Erase record and Exit windows Use the and keys to activate these windows Press ACCEPT button when there is a frame around Exit window to exit from the record menu Press the ACCEPT button and approve the operation when there is a frame around Erase record window to delete a record 21 TECHNICAL PROPERTIES Deep Search Coil General Search Coil Optional
17. the general condition of land formation in our country a ground setting system is established that will eliminate ground effect on the device 12 HOW GROUND SETTING IS MADE When the device is switched on it starts with the GROUND ADJUST mode Ground adjustment should be done before using the device for correct results During exploration when soil composition has changed and when ground adjustment has to be done again switch to ground mode by pressing the GROUND button and re adjust ground settings after checking existing settings 3 1191 13 Ground Setting Phases 1 When the device is switched on in LCD mode ground adjustment is displayed automatically Ji A IYA ONI 2 Lift the search coil 40 cm above ground and press the RESET button 3 When in ground mode the effect of ground on the device is displayed on the monitor as Ground Effect This effect will change when ground adjustment is made NOTE The search coil must be lifted 40 cm above the ground and the RESET button to be pressed in order to reset previous values otherwise following results will not be reliable 4 Make sure that there are no metal objects or cavities in the ground where ground setting will be made If ground setting could not be adjusted it will be repeated ina neighboring area 5 The operator lifts the detector search coil 40 cm above the ground and after pressing
18. tling is carried out as the reverse of the process described above CAUTION Do not take apart the screws that connect the Connecting piece and Search coil Take off only the telescopic tube without damaging cable coil and suitably store in the carrying case 1 2 General Search Coil Battery System Unit Deep Search Coil B Optional Headphone SEARCH COIL CONNECTION Transmits the data received from search coil to the Electronic system box The 5 pin A plugs shown in the above figure are connected to socket A on the system box HEADPHONE CONNECTION Enables signal sound to be switched from external loudspeaker to the headphone The B plug shown in the figure in the previous page is connected to socket B on the system box BATTERY CONNECTION The batteries shown in the previous page is located in the direction of the arrow in the system box and battery compartment lid is closed The battery is so placed that the poles on the battery is in contact with the springs mounted in the battery compartment USING THE LCD MODE NOTE The LCD system function of the device can only be used when 360x440mm search coil and 600x1000mm search coil is installed Install the 360x440mm or 600x1000mm search coil to the system box as described in the assembly section The device has two separate systems One of these systems is the LED System the other is LCD System To switch th