Home
NetClock version 3.6.7 Release Notes
Contents
1. Version 3 4 9 e The Frequency alarm classified as a Major alarm condition is no longer being asserted immediately upon the loss of qualified GPS reception O The Frequency alarm and its associated Major Alarm was prematurely being asserted as soon as the Holdover mode started Upon initial loss of GPS reception Since during the Holdover mode the oscillator and the NetClock s outputs are still within specifications the Frequency and associated Major alarms are now only being asserted if the Holdover mode expires without qualified GPS reception being restored yet e Leap Second notification improvement for NTP when a NetClock with version 3 4 8 software currently installed is syncing to other NTP servers Note This is applicable only to NetClocks operating in a Stratum 2 or lower configuration Not applicable to NetClocks syncing via GPS or IRIG input www spectracomcorp com 7 NetClock Release Notes Resolved an issue that NTP could keep the leap second indicator bits active for 1 2 minutes after the insertion of a Leap Second causing a Leap Second notification to be asserted for the following month as well Version 3 4 8 e Improved Stratum 2 operation that was previously incorporated in version 3 4 7 e Enabled unit logs to be obtained remotely via SSH sessions in addition to telnet sessions e Fixed a minor issue with the reported Antenna Status as read using SNMP Version 3 4 7 e Enhanced NTP Stratum 2 operatio
2. iced specced ac cnc ahs eps eto ca cece cess ee 2 Software enhancements iretsi ar vet E EE AEE E EE RE EEEE AEE a E ESE 5 Determining the version of software currently installed eee ceessceeneeceeeeceseeeceeneeceeaeeceaeeceeeeceeneeseeeeeeeeeees 11 Links to download NetClock software and user manual Updates 0 eeeeeeeeceeeeceseeeceeeeeceeeeeceeeeeceeeeesteeeesaeees 12 Sp ctracom Tech SUppOftsiiisiissssiesinio ian kEi eN E EEEE OEA AAEE ERE EAE EREE EEE E Eaa ER AE TEREE EDIE EAE 13 www spectracomcorp com 1 NetClock Release Notes Rev A 29 Oct 2014 New Features Version 3 6 2 e Added ability for users to be able to manually set the time o USER LCL for NTP RefID is the synchronizing reference o NTP can override USER handset time as a synchronizing reference o When time is USER set the NTP server remains in sync until reboot loss of power Holdover mode expires or until another external input reference such as GPS or NTP is restored e Allows users to set the NTP Local Clock Reference s default Stratum level o Per NTP specifications available range is Stratum 0 to Stratum 15 though it s recommended to use Stratum values of 2 through 15 only o With no external inputs present NTP selects the Local Clock Reference and NTP will become one less than its Stratum level if the Local Clock Reference is configured as Stratum 3 for instance NTP will become Stratum 4 with no external inputs present Setting this value t
3. 1 but a user can change this value to 4 if they wish for instance the GPS antenna has a partially blocked view of the sky causing it to drop to tracking only 3 satellites for periods of time throughout the day e Improved the text on the Front Panel LCD display window and on the System gt GPS Signal Status page of the web browser to more clearly indicate the input reference for synchronization e Applicable only to Option 04 Rubidium Oscillator installed Improved Rubidium oscillator 1PPS output operation o The IPPS output from the Rb oscillator will always be present and selected once the oscillator has locked even if the oscillator subsequently goes into Free Run mode and then back into lock mode again Version 3 5 0 e Fixed an issue with ASCII Data Format 90 output o While in GPS Standard mode factory default configuration the data output string was only changing the reported time every 3 seconds o While in Mobile GPS mode the data output string contained no time data e Fixed an issue with the Models 9388 and 9288 which could cause the RS 485 input to stop receiving data o If the input time being received from the NetClock reference stepped by more than one second the input time of the Ethernet time sever could stop being processed e An entry is now added in the Operational log when either the GPS receiver or SAASM GPS receiver for military DOD applications detects a leap second is pending
4. Shock o Updated Bash to address potential vulnerabilities CVE 2014 6271 CVE 2014 6277 CVE 2014 6278 CVE 2014 7169 CVE 2014 7186 and CVE 2014 7187 e Updated OpenSSL to version 1 0 1j o Addresses CVE 2014 3566 Poodle o Addresses other potential vulnerabilities such as the following CVE 2014 3505 CVE 2014 3506 CVE 2014 3507 CVE 2014 3508 CVE 2014 3509 CVE 2014 3510 CVE 2014 3511 CVE 2014 3512 and CVE 2014 5139 Version 3 6 6 Security updates to mitigate potential vulnerabilities e Updated OpenSSL to version 1 0 1g to mitigate CVE 2014 0160 HeartBleed potential vulnerability e Updated OpenSSH to version 6 6p1 e Updated the Apache web browser to version 2 22 27 System enhancements e Applicable only to time servers with a Rubidium oscillator installed Fixed the saving of an oscillator correction value e Modified the GPS Fault alarm to be a Minor Alarm instead of a Major alarm to allow Holdover operation e Improved attempted recovery operations of a GPS Receiver Fault alarm being asserted due to loss of communications with the on board GPS receiver e Removed risk of a potential but seldom observed Specapp fault and automatic restart o Symptoms appeared as if input power had been momentarily lost resulting in a reboot of the time server Note the occurrence of this condition is logged in the sys log file as usr bin appwatch Application terminated o Added a new CLI command to allo
5. Software Update Release Notes NetClock and Ethernet Time Servers ECO 0211 NetClock version 3 6 7 Release Notes Dear valued Spectracom customer We at Spectracom Corporation continuously strive to improve our products To this end we have released a software update Application software version 3 6 7 for the Spectracom NetClocks Models 9383 9389 9283 and 9289 and the Ethernet Time Servers Models 9388 and 9288 This software update upgrades the Application software of the NTP time servers to version 3 6 7 The version 3 6 7 and previous upgrades provide added benefits and minor enhancements to the operation of this equipment Highlights of the version 3 6 7 release are listed below Changes to software versions 3 3 0 3 4 0 3 4 1 3 4 2 3 4 3 3 4 4 3 4 5 3 4 6 3 4 7 3 4 8 3 4 9 3 5 0 3 6 0 3 6 1 3 6 2 3 6 4 and 3 6 6 are also listed for your reference Note One of the features incorporated with the earlier version 3 4 8 software is much faster NTP synchronization once the NTP time server is in sync with its primary input reference as indicated by the front panel Sync LED turning sold green This change was made possible by reducing NTP s Min poll value In order for the faster NTP sync to take effect NTP needs to be initially disabled and then enabled via the NTP gt General page of the web browser This step just needs to be done once in order to re write the NTP configuration files Table of Contents NEW Features
6. browser now displays the version of the installed NTP software for those customers who wish to know this version information Version 3 3 0 e Automatic FTP of NTP statistics files to a remote server o Added the capability to transfer automatically the NTP statistics files to a remote server via File Transfer Protocol FTP The statistics files transferred by this feature are loopstats peerstats and clockstats Each file contains statistics data for the current day The files are automatically transferred to the remote server 30 minutes into every hour 12 30 1 30 2 30 etc e Rubidium oscillator log now displays oscillator frequency counts applicable only to the Model 9283 with Option 4 Rubidium oscillator installed o The oscillator log for the Model 9283 with the optional Rubidium oscillator installed now logs the frequency counts of the 10 MHz output of the oscillator e Added IPSec IPV4 IPV6 as a standard feature o Added IPSec IP Security to the Models 9283 9289 and 9288 as a standard feature Note IPSec is a suite of protocols for securing Internet Protocol IP communications by using authentication and encryption algorithms on each IP packet in the data stream Network and client software must be able to support this feature in order to utilize it www spectracomcorp com 4 NetClock Release Notes Software enhancements Version 3 6 7 Security updates to mitigate potential vulnerabilities e Bash update Shell
7. een made to Australia s DST rules Version 3 4 0 e Improved the SpecUp update utility used to update software in the field o Improved the Spectracom SpecUp utility to improve the field update process e Vulnerability scans no longer disable NTP o Prevents vulnerability scans from potentially disabling the NTP service The resolution was verified using a Nessus vulnerability scanner e Resolved an issue in which SNMP would not restart correctly after a reboot o Fixed an issue in which SNMP might not restart correctly after equipment reboot e Updated installed OpenSSH and OpenSSL versions o To avoid potential security vulnerabilities in the OpenSSH and OpenSSL software updated OpenSSH to stable version 4 7p1 and updated OpenSSL to stable version 0 9 8e e Updated installed Apache web server version o Updated Apache to latest stable version version 2 2 6 and modified configuration files to prevent potential security vulnerabilities e NetClock with optional IRIG input could stop syncing to IRIG reference source Applicable only to the Model 9283 or 9383 when Option 6 IRIG input is installed o Prevents a potential buffer overflow condition in the IRIG input circuitry Version 3 3 0 e Serial ports now retain port settings during power cycle o Prevents the rear panel serial port s from switching from the multicast mode back to the interrogation mode of operation setting the Local System Clock values for these ports back to UTC t
8. enhancements were incorporated in this version Version 3 4 5 e Due toa recent change to the Global Positioning Satellite System GPS Holdover Alarms a Minor alarm condition are being asserted every 12 5 minutes Applicable only to the GPS based Models 9383 9389 9283 and 9289 www spectracomcorp com 8 NetClock Release Notes o Version 3 4 5 suppresses the Holdover alarm unless the NTP time server remains in the Holdover mode for at least five seconds Version 3 4 4 e Applicable only to NTP time servers with Option 3 Modem installed Resolved a potential issue that could prevent the optional Modem from being able to dial out after a power cycle occurs O Application software versions 3 3 0 through 3 4 3 may be unable to dial out after a power cycle occurs This version prevents this potential condition from occurring Version 3 4 3 e Modified the SNMP MIB files to allow them to be compiled on a wide range of SNMP Management programs e Specup Update utility saves all configuration files With the exception of network settings and certain security settings for either backup capability or to provide the ability to clone NTP time servers with similar values o The Specup backup utility backs up and restores the configuration files for the time server on a PC with the exception of network settings to prevent the chance of duplicate IP addresses and security items such as SSL keys and passwords to prevent chance of comp
9. ile consists of the Update files the Update instructions and a program called Specup which is run on this PC in order to transfer the update files into the NetClock using the Ethernet connection Refer to the Update instructions for information on performing the software update process NetClock user manual updates Manual updates reflecting the software changes have been uploaded to the Support page of Spectracom s website Please refer to http www spectracomcorp com Support HowCanWeHelpY ou Library tabid 59 Default aspx EntryId 119 to download the latest version of the NetClock manual Hard copies of the NetClock manuals may also be purchased from the Spectracom Sales department at US 1 585 321 5800 www spectracomcorp com 12 NetClock Release Notes Spectracom Tech Support Please contact one of the global Spectracom Technical Support centers for more information regarding any of these features or fixes USA www spectracomcorp com techsupport spectracomcorp com 95 Methodist Hill Dr Rochester NY 14623 1 585 321 5800 FRANCE www spectracom fr techsupport spectracom fr 3 Avenue du Canada 91974 Les Ulis Cedex 33 0 1 64 53 39 80 UK www spectracom co uk techsupport spectracom co uk 6A Beechwood Chineham Park Basingstoke Hampshire RG24 8WA 44 0 1256 303630 Thank you for purchasing the Spectracom NetClock Please let us know if you have any questions about this software update
10. ime when the unit was power cycled e Prevents an error caused by network settings being displayed on the front panel applicable only to the Model 9283 and the Model 9289 when Option 2 Front panel display is installed not applicable to the Model 9288 o Prevents a potential error that can occur when the network settings IP address net mask and gateway values are displayed on the front panel of the time server causing varying symptoms such as loss of GPS or the unit being unable to open a web browser session www spectracomcorp com 10 NetClock Release Notes Determining the version of software currently installed To determine the current application software version of your NetClock or Ethernet Time Server log in to the unit s web browser user interface Click on Status and Logs located on the bottom menu and then on System Status located on the left menu Scroll down to the Static System Information box which contains a line stating Application Rev is The number next to this is the current Application software version Refer to Figure 1 Main Menu Microsoft Internet Explorer File Edit Yiew Favorites Tools Help 2 ef 7 BD ake hpg Q sak X z x a A gt Search y Favorites g Address E https 10 2 128 24 cgi bin main cgi Links Status amp Log O SPECTRACOM You have logged in as admin Synchronizing Critical Operations Dynamic System Information Upti
11. ition to PEM formatted certificates o Added ability to load and convert PEM DER P7 PEM and P7 DER certificates for secure HTTPS connection to the web browser e New MD5 Authentication feature incorporated o Added ability to block NTP requests originating from computers with the incorrect MDS keys The user can now configure MDS to prevent NTP responses from NTP clients with invalid MD5 keys e Added support for NTPQ and NTPDC o Added ability to enable disable NTPQ and NTPDC status queries for remotely monitoring NTP performance www spectracomcorp com 3 NetClock Release Notes e Provided ability for a user to be able to reset all configuration settings back to the factory default values and erase all log entries o Added ability for an Admin account user to reset the factory configurations back to the factory defaults Note To speed up the process of resynchronization with GPS after resetting the configurations this function does not clear the GPS position However if it is desired to clear the GPS location for any reason a separate function has also been added to allow for the GPS receiver s position to be zeroed out as well Version 3 4 0 e Implemented a software Halt function o Added a Halt function process can be initiated via the web browser console port or SNMP that provides the equipment with additional time to shut down e Added the NTP version to the System Status web page o The System Status page of the web
12. me 0 years 0 days 2 hours 45 minutes 48 seconds Current internal temperature 36 50 C 97 70 F Major Alarm is OFF Minor Alarm is ON Time Sync status In Sync Time Source GPS NTP Service Status In Sync Stratum 1 Static System Information Product Name is Spectracom Corp Model 9283 Location of the Application Name is hs92XX current Application Application Rev is 3 2 2 f Application Date is 01 03 2007 software version SSH Revis OpenSSH 4 1p1 Figure 1 Application Software Revision Contained on the System Status Page www spectracomcorp com 11 NetClock Release Notes Links to download NetClock software and user manual updates Download the NetClock software update files The NetClock software update files can be downloaded from the Spectracom website To obtain the zipped NetClock software update files please visit http www spectracomcorp com Support HowCanWeHelpY ou Software tabid 61 Default aspx NetClock NOTE This software and equipment are governed by Unites States Export Control In order to obtain the software upgrade you must acknowledge that you understand this software cannot be exported to certain foreign nationals or countries After downloading the zipped upgrade file from our website unzip this file to a single name temporary folder of a PC such as either C Spectracom of C Temp that is networked with the NTP server The unzipped f
13. n syncing to other NTP servers on the network o When only syncing the NTP time server to other NTP servers on the network not syncing it to a primary input such as GPS IRIG or in the case of the Models 9388 and 9288 RS 485 ASCII data NTP input will now sync the System Time o With System Time now synced to NTP input the front panel Sync LED will now turn green while NTP data is being received from other NTP servers the front panel s displayed time not applicable to all Models will display the same time as NTP and the System System Time page of the web browser will now also show the same time as NTP e ACTS Server mode was re enabled applicable only to NetClocks with Option 03 Modem dial out enabled o ACTS Server mode stopped working in an earlier version of software Note ACTS Client mode was not affected by this software update e Fixed a minor issue that affects the ASCII data Format 90 applicable to NetClocks in GPS mobile mode operation only Not applicable to Models 9388 and 9288 O With the GPS mode configured as Mobile Mode the NetClock was not declaring that a 3 D fix was being obtained even with at least 4 satellites being tracked Since the ASCII data Format 90 provides the time of the last 3 D fix no time data was being provided in the ASCII output data stream e Fixed a minor issue with SNMP Gets that could cause SNMP to stop responding Version 3 4 6 e No software
14. o any value other than 15 allows the NTP server to always be an available time server whether or not any external input references are present o The factory default value of Stratum 15 causes NTP to go to Stratum 16 with no external inputs available The NTP server will then typically be ignored by NTP clients as a network time source e Added NTP Server burst mode capability when syncing to other NTP Servers Version 3 6 1 e Added NTP iburst mode capability when syncing to other NTP Servers o With NTP iburst mode enabled each time NTP restarts a volley of eight NTP packets instead of just one is exchanged between the NTP server and each configured NTP Server to initially sync NTP in about ten seconds or so Version 3 6 0 Enhanced Security e Increased default RSA Keysize to 2048 for HTTPS certificate creation e Increased default Keysize for RSA RSA1 to 2048 bits and added ecDSA 521 bits for SSH keys DSA keys remain at 1024 bits Other new features e Added capability to display a login text banner o A banner can now display a custom text message if desired when logging in via the web browser the rear panel Serial Setup Interface connector telnet and SSH SSH keys only and password only Version 3 5 0 e No new features were added in the version 3 5 0 software update www spectracomcorp com 2 NetClock Release Notes Version 3 4 9 e No new features were added in the version 3 4 9 s
15. oftware update Version 3 4 8 e Added ability to configure 30 Minute Time Zone Offset values via the web browser instead of just whole hours Version 3 4 7 e Faster NTP synchronization Once the NTP time server has declared Sync with its input reference GPS IRIG or Option 03 Modem dial out or ASCII RS 485 data with the Models 9388 and 9288 as indicated by the front panel Sync LED turning green NTP will now achieve synchronization as indicated by Stratum 1 or Stratum 2 much faster than in earlier versions of the NetClock software The NTP s minpoll interval was changed in this version from 64 seconds to 16 seconds so NTP can poll the System Time much faster resulting in NTP sync to Stratum 1 after each power up reboot in about 5 minutes instead of about 17 minutes as normally occurred in earlier versions of software Version 3 4 6 e Implemented ability to send raw GPS time via NTP O Added capability for the user to select either UTC or GPS time scale for the NTP output This setting is available on the NTP General page of the web browser Version 3 4 4 e Implemented GPS receiver mobile Continuous operation o Added continuous mode operation which allows the GPS receiver to remain in sync while the NTP server is in a moving platform Dynamic codes were added to support Air Land Sea or Stationary mode Version 3 4 3 e Added capability to install SSL certificates using PKCS P7 format in add
16. or any other issues concerning your Spectracom equipment Sincerely The Spectracom Tech Support Staff www spectracomcorp com 13 NetClock Release Notes
17. romising security e Modified the XOR checksum calculation in the Data Format 90 ASCII output data stream e Modification added to the Option 3 Modem dial out input functionality to help prevent the chance of distorted data due to a poor phone connection from potentially being utilized e GPS longitude values with three digits such as W 123 can now be manually entered via the web browser Version 3 4 2 e Prevents the internal logs from causing the CF card to become full e Fixed the front panel GPS LCD display that stopped working correctly applicable to the Models 9383 and 9283 as well as the Models 9389 and 9289 when Option 2 Front panel is installed e Improved the display of the correct antenna cable delay value in the Status and Logs GPS Signal Status page of the web browser Version 3 4 1 e POST Power On Self Test reporting when using a new version of the microprocessor not applicable to any units shipping prior to the March 2008 time frame www spectracomcorp com 9 NetClock Release Notes o With a new version of the microprocessor module now being used the POST test was failing to report the versions of the data output processors This was causing a POST failure alarm Version 3 4 1 allows the versions to be read correctly and clears the POST failure alarm e Updated DST Daylight Saving Time change rules for Australia o Updated the Local System Clock s DST rules to reflect changes that have b
18. us time stamp o The purpose of this test validation is to discard any time jumps on the RS 485 ASCH input data induced by potential noise on the RS 485 bus e Added optional NTP as Primary mode capability to prevent the Frequency alarm and its associated Major alarm from being asserted when the NTP server is synced to only other NTP servers no GPS input for example e In the Ethernet time servers Models 9388 and 9288 updated the factory default year value for Format 0 ASCII RS 485 data input to 2013 Version 3 6 0 Security package updates to mitigate potential vulnerabilities e Updated OpenSSL package to version 1 0 1C e Updated OpenSSH package to version 6 1p1 e Updated Apache web browser to version 2 2 22 System enhancements e Added a new Standard Mode Minimum Number of Satellites drop down field to the System gt Set System Mode page of the browser o This drop down allows a user to determine if the minimum number of tracked satellites in the factory default GPS Standard Stationary mode should be either one or four satellites to remain in full sync mode Previous to version 3 6 0 this minimum number of satellites value was hard coded in software to be a minimum of just one satellite being tracked after initial sync in order to prevent the NetClock from going into the Holdover mode www spectracomcorp com 6 NetClock Release Notes o The factory default value for this field is
19. w a user to restart SNMP if this Specapp fault does happen to occur Default SNMP does not restart This new CLI command can be issued one time to have SNMP restart sys snmp restarton restartoff Version 3 6 4 System enhancements e Corrected monitoring of Rubidium units to resolve intermittent Frequency Error and associated Major alarm assertion on transition from Holdover mode to Sync state www spectracomcorp com 5 NetClock Release Notes o Saves Rubidium oscillator s DAC value on 24 hours intervals by default However there is at least 3 5 hours of sync the current Rubidium DAC is saved on entry into Holdover mode e Improved processing of the GPS receiver s 1PPS output to the system Version 3 6 1 Security updates to mitigate potential vulnerabilities e Added changes to Apache web browser to mitigate the ClickJack potential hijack vulnerability System enhancements e Fixed a defect with the ability to import a new X509 HTTPS certificate o Specific to Application software version 4 8 7 only new X509 certificates could not be imported in order to replace the default Spectracom HTTPS certificate X509 certificates can now be FTP SCP transferred into the NTP server again if desired e Applicable to Ethernet time servers Models 9388 and 9288 only Added test validation of the received RS 485 ASCII input time stamps to ensure each subsequent time stamp does not differ by more than two seconds from the previo
Download Pdf Manuals