1. 422 485 communication interface With the RS 422 485 communication interface of the XGT Panel data communication like 1 1 1 N multi drop N M multi master with PLC inverter and various kinds of control units is possible In this case communication cable must be wired properly Cable wiring for communication with LS PLC is as follow and for more details refer to the XGT Panel user s manual 1 RS 422 communication wiring pl re tet ADA Fo Fel Fe on ToN lt pes Terminating SDA Gal ee ee beard SDB EEan SG ee Master Slave Slave Slave 2 RS 485 communication wiring RADA RDB SDA Terminating resistor SDB 3G Master Slave Slave Slave 1202 1 2W Terminating Resistor is Recommended 6 Communication System Confiquration This chapter describes information about the communication system configuration 1 1 1 communication system configuration The XGT Panel has two independent channels which are RS 232C and RS 422 485 It is possible to configure flexible 1 1 communication system with them The following is an example configured with a XGT Panel a PLC and an inverter 2 1 N communication system configuration This part explains 1 N multi drop configuration with RS 422 485 channel of the XGT Panel In this case the XGT Panel becomes a master and other units become slaves The total settable station number is 32 station 0 31 O i p lt gt RAS 2
2. The password is less than 10 digits If the password is set to O it is cleared Caution gt Do not forget the password If the password is forgotten you may not be able to use the major functions of the product 6 Date Time set XP10BKB DC type only 1 When the cursor is on 3 of 5 2 menu pressing W key leads to the following menu 4 DATE TIME SET 5 BUZZER VOLUME SET 6 BACKLIGHT SET If you select 4 current date and time will be displayed They can be changed with SET key The date and the day of the week must correspond 7 Buzzer backlight set 1 If you select 5 of 6 1 menu the volume level of the buzzer can be adjusted 2 Ifyou select 6 of 6 1 menu backlight can be ON OFF 3 In case that backlight option is selected if no key is inputted during setting time backlight will be off automatically In this case whichever key is pressed the function assigned to the key is not executed but backlight is just on 8 Changing screen 1 When the power is supplied to a XGT Panel the defined first screen will be displayed If it doesn t exist the first defined screen will be displayed 2 In monitor mode the defined screen list will be displayed if ESC key is pressed Using A V ENT key it is possible to change the screen 3 In monitor mode pressing 4 gt key the screen will move to the defined previous next screen for each If the screen doesn t exist no move wil
3. is limited to the HMI itself only It is not valid for the whole system which the HMI is attached to
4. 32C RS 485 3 N M multi master communication system configuration The XGT Panel supports N M multi master and multi slave communicat ion The XGT Panels which are set as a master communicate with slaves in turn using the token In this case every XGT Panel set as a master must have same communication setting data except HMI station number The total settable station number is 32 station 0 31 xer 16 xer eo xer t0 9 9 o D 9 9 a w G ry a tv JAO Y OL IFY 9 O amp ie d 5 5 3 AS 422 485 7 Operation 1 Introduction This chapter explains the operation of the XGT Panel For more details refer to the user s manual The function assigned to F1 key is executed For details about the function refer to the user s manual The function assigned to F2 key is executed F3 The function assigned to F3 key is executed F4 The function assigned to F4 key is executed Display the names of screen defined Cancel the change of the value or go back in case of menu In case of alarm clear the alarm message displayed in the screen The function assigned to A key is executed When changing the value of the digit tag increase the number of the current cursor position by 1 Move up the cursor in menu The function assigned to W key is executed When changing the value of the digit tag decrease the number of the current cursor position by 1 Move down the cursor
5. A N Warn j ng This symbol indicates the possibility of death or serious injury Caution This symbol indicates the possibility of injury or damage to property gt The meaning of each symbol in this datasheet and on your equipment is as follows f This is the safety alert symbol Read and follow instructions carefully to avoid dangerous situation i This symbol alerts the user to the presence of dangerous voltage inside the product that might cause harm or electric shock means paying attention because of danger of electrical shock gt Store this datasheet in a safe place so that you can take it out and read it whenever necessary Always forward it to the end user Do not contact the terminals while the power is applied Risk of electric shock and malfunction Protect the product from being gone into by foreign metallic matter Risk of fire electric shock and malfunction Do not charge heat short solder and break up the battery It can cause injury and fire by explosion and ignition Caution Be sure to check the rated voltage and terminal arrangement for the module before wiring work Risk of electric shock fire and malfunction Tighten the screw of terminal block with the specified torque range If the terminal screw looses it can cause fire and electric shock Use the product in an environment that meets the general specifications contained in this datasheet Risk of electrical shock fire erroneo
6. DATA SHEET LS Programmable Monitoring Unit XGT Panel Series When using LSIS equipment thoroughly read this datasheet and associated manuals introduced in this datasheet Also pay careful attention to safety and handle the module properly Store this datasheet in a safe place so that you can take it out and read it whenever necessary LS Industrial Systems Co Ltd Davis Controls A Breed Above fhe Rast Davis Controls Ltd ts the authorized distributor of LOIS equipment and control solutions throughtout Canada Founded in 1933 Davis Controls represents a strong and balanced portfolio of world class products From head office facilities located in Oakville Ontario Davis Controls connects customers seeking high quality automation solutions with global manufacturers of state of the art products You can contact us at Toll Free Canada 800 701 7480 Toll Free USA 300 386 4159 Email infoiidaviscontrols com Website www dawiscontrols com Thank you for your business and your interest in L515 solutions LS constantly endeavor to improve our products so that information in this datasheet is subjected to change without notice 10310000481 Ver 1 2 2010 10 Safety Instructions gt To prevent injury and property damage following these instructions gt Incorrect operation due to ignoring instructions will cause harm or damage the seriousness of which is indicated by following symbols
7. ed on the tag with ENT key 4 Alarm 1 In alarm state the alarm message is displayed at the bottom of the screen flickering If the buzzer option is set it will beep At this time only ESC and ALM key are valid In XP10BKB DC type two time data will be saved One data is the time when the alarm happened and the other data is the time when it was cleared 2 In monitor mode the following messages will be displayed if ALM key is pressed 1 ALL ALARM LOG LIST 2 DEFINED ALARM LIST If you select 1 the recent alarm messages will be displayed up to 100 items in order If you select 2 the recent Defined Alarm list will be displayed up to 10 items in order 5 Password 1 In case that password is set to the XGT Panel it is impossible to write data to the writing enabled tag and to execute the function key set password at In this case it doesn t operate normally until the password is released 2 In monitor mode the following menu will be displayed if ENT key is pressed 1 PASSWORD UNLOCK 2 PASSWORD LOCK 3 PASSWORD CHANGE If you select 1 the password become unlocked if you input correct password If there is no password the following message will be displayed PASSWORD NO EXIST In state that password is unlocked the operations which is set password to is executable This is valid until the password is locked If you select 2 the password is locked If you select 3 the password is able to be changed
8. in menu Continued on next page Continued from previous page Function description The function assigned to lt key is executed If there is no defined function go to the previous screen defined in the current screen When changing the value of the digit tag move the current cursor position to the left 7 The function assigned to key is executed If there is no definition go to the next screen defined in the current screen When changing the value of the digit tag move the current cursor position to the right SET Enter the value changing mode In value changing mode write the set value Enter the setting menu Execute the selected item in menu If the key is valid the buzzer beeps 1 time if not 3 times 3 Writing data 1 The tags which are possible to write the data are digit tag and button tag But in case that password is set password must be unlocked before writing the data 2 In monitor mode pressing the SET key leads to value changing mode If there s no tag to be written to it will be invalid 3 The cursor will be located on the nearest tag to the left top of the screen 4 If the SET key is pressed again the cursor moves to the next writing enabled tag 5 In case of digit tag after changing the value of the tag with arrow keys execute writing the value with ENT key In case of button tag when the cursor is located on the tag execute the order defin
9. l happen 4 In case that screen saver option is set if no key is inputted during setting time the screen will be move to the defined screen At this time whatever key is inputted the screen won t move and the function assigned to the key will be executed If the screen doesn t exist no move will happen 9 Continuous keystroke When pressing a key if the key is held down for more than 1 second the function assigned to the key will be executed repeatedly 8 Dimension mm 1 External dimension i XET LS HE F a q Fa Fa j ec am CA T lt 4 r mn 1 ii S 2 Cutting dimension Pa A i LO o n co a F 141 0 5 _9 Warranty 1 Warranty period LSIS provides an 18 month warranty from the date of the production 2 Warranty conditions For troubles within the warranty period LSIS will replace the entire HMI or repair the troubled parts free of charge except the following cases 1 The troubles caused by improper condition environment or treatment except the instructions of LSIS 2 The troubles caused by external devices 3 The troubles caused by remodeling or repairing based on the user s own discretion 4 The troubles caused by improper usage of the product 5 The troubles caused by the reason which exceeded the expectation from science and technology level when LSIS manufactured the product 6 The troubles caused by natural disaster 3 This warranty
10. s Each memory area can be up downloaded in part 12 KEY F1 F4 ESC ALM amp 4 gt SETENT Latch area is z supported in System User area M000 M899 900 Word XP10BKB D memory C Saem M900 M999 100 Word s flags Standard Certification UL CE Size W x H x D 150 x 93 x 35 Panel Cut W x H 141 x 87 Kg 5 Communication Specifications 1 Up Download interface The PC and the XGT Panel should be connected by RS 232C communication interface for up downloading program data Wiring is as below xXGT Panel Pin assignment and direction ee a Ts a E ee Download means that program data is transmitted from PC to the XGT Panel and upload is case to be opposed Downloaded program data is preserved permanently in state of being stored in flash memory even though power is off To download program data to the XGT Panel it must be powered with DC 24V and connected to PC with up download cable Then use the up download menu of Panel Editor 2 RS 232C communication interface With the RS 232C communication interface of the XGT Panel data communication with PLC inverter and various kinds of control unit is possible In this case communication cable must be connected properly Cable wiring for communication with LG PLC is as follow and for more details refer to the XGT Panel user s manual Pin assignment and MASTER K main unit By G4M CPUC in LS PLC does not support 5V supply 3 RS
11. tude 10sf lt 57 Hz ___ 0 075mm 10 times 5 Vibration 57sfs150Hz 98m ineach direction IEC61131 2 for _10sf lt 57Hz 0 0375mm XYZ 57 lt f lt 150 Hz 49 me LCa Maximum shock acceleration 147 m 15G Shocks curation time 11 ns IEC61131 2 Pulse wave half sine wave pulse 3 times in each of X Y and Z directions Square wave 500V LSIS Internal impulse noise Standard Electrostatic f IEC61131 2 AE Voltage 4 kV contact discharge IECG1000 4 2 Radiated IEC61131 2 Noise electromagnetic immunity oe EC61000 4 3 Fast transient 1IEC61131 2 8 Atmosphere Free from corrosive gases and excessive dust a 5 Altitude for icon use 27 500 MHz 10 V m Pollution 2 or lower Power supply connector 2 pin connector for t he external 24VDC input opt o2 Mode O S downloading mode Variable resistor Variable resistor for adjusting contrast RS 422 485 connector RS 422 485 connector for communication channel 2 RS 232C connector RS 232C connector for communication channel 1 4 Performance Specifications Specifications Remark XP10BKA DC XP10BKB DC Refer to 4 9 5 1VDC RS 232C Connector User s input power 21 6V 26 4VDC Power supply connector Manual for 5VDC Display LED Back Light 192 64 Dot a Communication RS 232C RS 422 485 Independent Interface 2 channels Memory 256 Kbyte English Chinese Korean Up Download spec Speed M310 bp
12. us operation and deterioration of the HMI Be sure that external load does not exceed the rating of output module Risk of fire and erroneous operation Do not use the HMI in the environment of direct vibration Risk of electrical shock fire and erroneous operation Do not disassemble repair or modify the HMI Risk of electrical shock fire and erroneous operation When disposing of HMI and battery treat it as industrial waste Risk of poisonous pollution or explosion Precautions for use gt Do not detach PCB from the case of the product and do not modify the product gt Cellular phone or walkie talkie should be farther than 30cm from the product Input signal and communication line should be farther than minimum 100mm from a high tension line and a power line in order not to be affected by noise and magnetic field Before handling the product Before using the product read the datasheet and the User s manual through to the end carefully in order to use the product efficiently 10310000482 XGT Panel User s Manual 1 Introduction This data sheet provides brief information about characteristics configuration and usage of the XGT Panel 2 General Specifications No nem Specifications Standard q Operating ow 450 C 32 F 122 F temperature temperature 3 Operating 5 85 RH non condensing Humidit 4 Storage 5 85 RH non condensing humidity Occasional vibration Sweep count _ Ampli
Download Pdf Manuals
Related Search
Related Contents
K5902055-00 User Guide Coronis Fusion 6MP_for OPERATING & SAFETY INSTRUCTIONS Viewsonic VOT120 PC Copie de Contrat d` Assurance Implant cochléaire 2011 Manuale - Gesint Srl Imaginez les possibilites none I 2613Q Instructions / Assembly User`s Manual - UST Research Inc. USB 1 4 2 5 3 6 Copyright © All rights reserved.