1. 22320 info effecta se E Control display Language Choose desired language by pressing any of the flags on the screen If change of language is desired please open OTH ER SETTINGS where language change can be done again Home screen On the home screen there is a image of the boiler with temperature readings of the flue flow of first heating circuit and boiler temperature A CO2 vaule is displayed only in operation phase if the a lambda probe is used A flame icon indicates the flame value visual inside the boiler in percent If the electrical heater is used and applicable to the system a current consumption will be displayed At the bottom part a operating mode will normally be displayed for instance Ignition pre operation opera tion phase etc Main menu When pressing the touch display three icons will ap pear In this quick start guide you will be asked to enter the different menus in order to do different set tings P OPERATION effecta Il ill El HEATING SYSTEM Effecta AB Vastra R gdalsv gen 21 434 99 Kungsbacka 0300 22320 info effecta se E Program setup fan Controller setup Press anywhere on the display and then press the OPE RATION icon Operation settings menu Use the and buttons together with OK and the Return key to navigate the menu system Confirm that burner is set to OFF Fan menu Enter the FAN menu a passcode is required whi
2. One room sensor is used for each heating circuit using this program The active sensors in this set up is the flow sensor and room sensor It is possible to use the ENERGY SAVER function to set back the room temperature with the de sired amount of degrees on two different times each individual weekday Recommended to use when The building uses radiators and the room sensor is placed in a loca tion where it isn t affected by direct sunlight or chill from doors opening and closing It should be placed in a central location of the building and not on a outer wall Not recommended to use when The building uses radiant floor heating under floor heating Effecta AB Vastra R gdalsv gen 21 434 99 Kungsbacka 0300 22320 info effecta se effecta m Heating program options Outdoor If the program OUTDOOR is choosen the shunt motor will regulate the shunt valve to maintain a certain room temperature getting it s reference from the outdoor sensor The temperature to the flow is determined with the help of a heating curve and adjustment in the program This is also known as weather compensation The same outdoor sensor can be used for all three heating circuits running on the same program option The active sensors in this set up is the flow sensor and the outdoor sensor It is possible to use the ENERGY SAVER function to set back the flow temperature with the desi red amount of degrees on two different times each individ
3. VER 3 0 Feeder settings Start dose Support dose Pellets diameter Run start dose Run supp dose Run oper dose effecta mu YU 3 29 If the feeder isn t running it is likely that under pressure over the boiler isn t sufficient Make sure that the burner fall shaft is plugged at all time when the black plastic fall hose is out of the burner Effecta AB Vastra Ragdalsvagen 21 434 99 Kungsbacka 0300 22320 info effecta se m Calibration of feed dose Suction version Controller setup Press anywhere on the display and then press the OPE RATION icon Operation settinys menu Use the and buttons together with OK and the Return key to navigate the menu system Confirm that burner is set to OFF Feeder menu Enter the FEEDER SETTINGS menu Change the pellets diameter to 6 or 8 mm pellets Change the start dose value to 48s which will get you reasonably close to the correct start dose value Q cmm Operation settings Burner Fan Temperature set Information Service Installation VER 3 0 Feeder settings Support dose Pellets diameter Run start dose a a Run supp dose Run oper dose Fr A U A correctly adjusted start dose is one of the most critical and important steps of a comissioning process If the start dose is incorrect it will give the wrong output on the boiler which might create operational issues excessive wear on par
4. all time when the black plastic fall hose is out of the burner Effecta AB Vastra Ragdalsvagen 21 434 99 Kungsbacka 0300 22320 info effecta se effecta m Calibration of feed dose Suction version Calibration of feed dose on a boiler equipped with a suction unit When the on board pellets storage has been filled it is time to calibrate the feed rate Remove the front casing of the fuel store The internal fuel store and burner unit will be visual Remove the fall shaft connection by removing the elbow coming out from the storage For refe rence see illustration on page 15 Place a container underneath the hole to the feeding opening where the elbow used to connect to the storage to collect the pellets that will be fed during a auger filling procedure The hole down the fall shaft to the burner where the black plastic hose where connected origi nally needs to plugged temporarily in order to be able to build under pressure in the fire box and allow the auger to feed in test mode Enter the OPERATION menu and then INSTALLATION menu Activate the FILL FEEDER function which will force feed pellets for 15 minutes Meanwhile the auger is filling up tap the auger repea tedly to ensure that it is packed with fuel When pellets comes out at the end of the auger the fill feeder should be set back to NO and then directly back to ON to have a full 15 minutes feed of pellets to make sure enough pellets is in the auger Collect
5. model Suction model The calibration pro The calibration process The calibration pro cess is described on is described on page cess is described on page 8 9 10 11 page 12 15 Effecta AB Vastra R gdalsv gen 21 434 99 Kungsbacka 0300 22320 info effecta se 7 effecta m Calibration of feed dose Auger version Controller setup Press anywhere on the display and then press the OPE Operation settings Burner RATION icon a Operation settings menu Temperature e t Use the and buttons together with OK and the Return Information key to navigate the menu system Service Installation Confirm that burner is set to OFF VER 3 0 Feeder menu Enter the FEEDER SETTINGS menu Feeder settings Change the pellets diameter to 6 or 8 mm pellets Support dose Pellets diameter Run start dose Run supp dose Run oper dose Calibration of feed dose with a auger fed boiler If the boiler is attached to a external feeding auger the start dose value needs to be veriefied ac cording to the below information Remove the black plastic hose which connects the feeding auger with the burner unit Place some sort of container underneath the plastic hose to collect the pellets that will be fed during a auger filling procedure The hole down the fall shaft to the burner where the black plastic hose where connected origi nally needs to plugged temporarily in order to be able to build under pressure in
6. the pellets in a bag or container during this 15 minute feed Do not stop the feeding process it is critical to have a properly packed and filled auger in order to calibrate the feed rate in the next step A correctly adjusted start dose is one of the most critical and important steps of a comissioning process If the start dose is incorrect it will give the wrong output on the boiler which might create operational issues excessive wear on parts and even be dangerous in extreme situations nay Effecta AB Vastra Ragdalsvagen 21 434 99 Kungsbacka 0300 22320 info effecta se m Calibration of feed dose Suction version Setting the start dose When the auger is properly packed and filled enter the OPERATION menu and open the FEEDER SETTINGS menu and then press RUN START DOSE Collect the pellets being fed during the test start dose process It should be exactly 40cl If it is less increase the amount of seconds of the start dose and run another test It the start dose is greater than 40cl decrease the amount of seconds for the start dose and then run the test start dose again Keep testing until the start dose being fed is exactly 40cl When this step has been processed the boiler is to be reassembled again by putting the fall shaft hose back in to the burner NOTE A good value to begin with is 48s for the start dose It will take the initial tests close to 40cl of feed rate The elbow connecting the fall shaft with t
7. we will in this document try to explain the basic functions Please use the users manual as reference if deeper information is needed For the circuits to work you need the following components installed Components for heating circuits Amount used per heating circuit ohunt valve 3 way 1 pcs per heating circuit Shunt motor 120s ESBE 1 pcs per heating circuit Flow sensor article 301701 1 pcs per heating circuit Outdoor sensor article 301702 1 pcs common for all available heating circuits Room sensor article 30171 1 pcs per heating circuit E Activating the heating system menu Heating system menus Shunt control 1 The flow sensors enables and activates the menus for Program Constant flow each heating circuit The first flow sensor needs to be Flow temp 22 20 C connected to G7 on the main board in order to activate Radiator pump heating circuit one The second and third heating circuit MOLE is controlled from the expansion board and are at port GO PIECES and G10 TE E d AT NOTE If the flow sensor for the desired heating circuit isnt connected the menu for the circuit will not appear in the controller A electrical diagram is available in the full manual for the Komplett Ill boilers E Heating program options Room If the program ROOM is choosen the shunt motor will regulate the shunt valve to maintain a certain room temperature getting it s reference from the room sensor
8. EFFECTA KOMPLETT III 20 25 35 kW COMISSIONING GUIDE QUICK START GUIDE effecta Rev HA 015 02 18 effecta Em Symbols in the document Note The icon is shown when a important notice of the products needs to be understood e High voltage When the icon is shown extra caution needs to be taken since live parts of the boiler is pos sible to contact without them being isolated Personal injury or even death may occur All installations must be done by a trained professional and comply with current building redula tions Hot surfaces ed The icon is shown when there is risk for personal scaldings or burns Em Introdction This guide will not replace the service and or user manual of the product The guide is only designed to be a help on first start up of the product as well as a guide through the commis sioning process All parts and menus of this document is described in depth in the product manual Effecta AB Vastra R gdalsv gen 21 434 99 Kungsbacka 0300 22320 info effecta se m Table of content effecta mm P 2 Introduction P oymbol description p Table of content P 4 Check list before powering up the unit 5 Controller Eo Controller setup fan P 7 Controller setup feeder B Calibration of feed rate Auger model P 9 Calibration of feed rate Auger model ELIO Calibration of feed rate In
9. arameter Temp G1 min is the temperature within the boiler where the Backend protection function will be enabled In the above example the function will be activated when the temperature drops below 60 C The function will then restrict the flow temperature down to the Max Flow temp which in the above example is set to 20 C Since the draw of hot water is limited to a minimum while the backen protection function is active the boiler temperature G1 will then rise and when the boiler tem peratures reaches 61 C the shunt motor will slowly start to open again effecta E my OPERATION HEATING SYSTEM OTHER Shunt control 1 Program Constant flow Flow temp 22 20 C Radiator pump On Constant flow 60 C Enegy saver gt Backend prot Temp G1 min Max flow temp Boiler warranty is void if the backend protection function isn t activated when heating circuits are connected to the back connections of the boiler Effecta AB Vastra R gdalsv gen 21 434 99 Kungsbacka 0300 22320 info effecta se effecta mm E Heating circuits Setting up the heating circuits All Komplett Ill can control up to three individual heating circuits with a great variety of programs as well as day time set back To set up the heating circuits it is important to have the project docu mentation available in order to set the system up as it has been sold originally The layout and controls can be done in more than fifty ways and
10. ch is 2233 The fan values are set up during operation with a flue analyzer according to the installation manual We can however recommend the following values to get the boiler operating enough to be able to measure with a flue analyzer 20kW 25kW 35kW Fan burner 515 96 65 515 0 5 Flue boiler 6596 15 90 The Fan burner low parameter is set to ON if you which to have the low power output mode activated We recom mend to have it activated on a Komplett Ill Light which di rect feeds any heating circuit without a accumulator tank Please leave the menu by pressing the Return key repea tedly until the home screen appears Operation settings Burner Feeder settings Temperature set Information Service Installation VER 3 0 Fan Flue boiler Fan burner low Fan alarm Fan alarm Effecta AB Vastra R gdalsv gen 21 434 99 Kungsbacka 0300 22320 info effecta se effecta mum effecta mm E Program setup feeder settings Calibration of feed dose The most critical part of the commissioning is to calibrate the feed doses of pellets correctly It is therefore of outmost importance that it is done precisely and according to this manual If the feed doses isn t setup according to our recommendations the boiler will deliver a faulty output which can damage the system and it will most likely also result in unstable operation of the product Auger fed model Integrated fuel store
11. entral location of the house where direct sunlight or chill from doors doesn t interfere with the room temperature Constant If the program CONSTANT is choosen the shunt motor will regulate the shunt valve to maintain a constant temperature to the flow getting it s reference from the flow sensor The active sensors in this set up is the flow sensor It is possible to use the ENERGY SAVER function to set back the flow temperature with the desi red amount of C on two different times each individual weekday Recommended to use when Any case where a separate heating controller is used Effecta AB Vastra R gdalsv gen 21 434 99 Kungsbacka 0300 22320 info effecta se effecta mm m Heating program options Cylinder If the program CYLINDER is choosen the shunt motor will regulate the shunt valve to maintain a constant temperature to the flow getting it s reference from the flow sensor This is a very simple way to control the temperature going to a remote cylinder where there is no possibility to connect a sensor measuring the actual cylinder temperaure The active sensors in this set up is the flow sensor It is possible to use the ENERGY SAVER function to set back the flow temperature with the desi red amount of C on two different times each individual weekday Hecommended to use when The cylinder is very remote without possibility to connect a sensor Cylinder 2 If the program CYLINDER 2 is choosen the shunt motor w
12. he on board storage Remove it by un winding the two M8 nuts Operation settings Burner Fan Temperature set Information Service Installation VER 3 0 Feeder settings a R Citar ANCE 7 dose Pellets diameter Run start dose Run supp dose Run oper dose effecta mm Ue foie If the feeder isnt running it is likely that under pressure over the boiler isnt sufficient Make sure that the burner fall shaft is plugged at all time when the black plastic fall e hose is out of the burner Effecta AB Vastra R gdalsv gen 21 434 99 Kungsbacka 0300 22320 info effecta se E Program setup temperature set Temperature set Press OPERATION and then open TEMPERATURE SET menu In the temperature set menu you will set the desired stop and start temperature of the burners on off to heat the water volume within the boiler Our recommendation is to have on at 65 C and off at 75 C These temperatures is not at all the same or in commu nication with the heating circuits used to heat the house It is only the internal temperature within the boiler body E Program setup effect output Effect output Press OPERATION and then open the INSTALLATION menu ocroll down to Effect high speed and set the boilers high speed output at the desired effect Never use a higher output than the rating of the product If the boiler also will be used with a low power output the Effect lo
13. ical to have a properly packed and filled auger in order to calibrate the feed rate in the next step A correctly adjusted start dose is one of the most critical and important steps of a comissioning process If the start dose is incorrect it will give the wrong output on the e boiler which might create operational issues excessive wear on parts and even be dangerous in extreme situations Effecta AB Vastra R gdalsv gen 21 434 99 Kungsbacka 0300 22320 info effecta se m Calibration of feed dose Integrated fuel store version Setting the start dose When the auger is properly packed and full enter the OPERATION menu and open the FEEDER SETTINGS menu and then press RUN START DOSE Collect the pellets being fed during the test start dose process It should be exactly 40cl If it is less increase the amount of seconds of the start dose and run another test It the start dose is greater than 40cl decrease the amount of seconds for the start dose and then run the test start dose again Keep testing until the start dose being fed is exactly 40cl When this step has been processed the boiler is to be reassembled again by putting the fall shaft hose back in to the burner The plastic hose is the fall shaft for pellets in to the burner and should be removed in order to collect and measure the amount of pellets being fed Operation settings Burner Fan Feeder settings Temperature set Information Service Installation
14. ill regulate the shunt valve to maintain a set temperature in the cylinder The cylinder sensor is connected on port G17 on the expansion board The active sensors in this set up is the flow sensor and a sensor in the cylinder It is possible to use the ENERGY SAVER function to set back the flow temperature with the desi red amount of C on two different times each individual weekday Recommended to use when Always when a cylinder is used where a sensor can be wired back to the boiler Hydraulic schematics For hydraulic references please see the full manual for the Komplett Ill Effecta AB Vastra R gdalsv gen 21 434 99 Kungsbacka 0300 22320 info effecta se effecta mum E Customer details and information User name User adress Installing company Effectas order no Serial no Commissioning engineer E Customer details and information Boiler start temp G1 C Boiler stop temp G1 e Boiler start temp G6 only when G5 amp G6 is active C Boiler stop temp G5 only when G5 amp G6 is active C Max G6 only when G5 amp G6 is active C Max G1 only when G5 amp G6 is active C Start dose value o otart dose measured value ci Fan burner Flue boiler Fan burner low On Off Fan burner low if low effect On Flue boiler if low effect On Effect high speed kW Effect low speed if activated kW Back end
15. lets diameter to 6 or 8 mm pellets Run supp dose Run oper dose 9 3 m9 9 Calibration of feed dose with a boiler equipped with a integral fuel store If the boiler is equipped with a intergrated fuel store on any side the start dose value needs to be veriefied according to the below information Hemove the front and or side casing of the fuel store The internal fuel store and burner unit will be visual Remove the black plastic hose which connects the feeding auger with the burner unit Place some sort of container underneath the plastic hose to collect the pellets that will be fed during a auger filling procedure See illustration on page 11 for further information The hole down the fall shaft to the burner where the black plastic hose where connected origi nally needs to plugged temporarily in order to be able to build under pressure in the fire box and allow the auger to feed in test mode Enter the OPERATION menu and then INSTALLATION menu Activate the FILL FEEDER function which will force feed pellets for 15 minutes Meanwhile the auger is filling up tap the auger repea tedly to ensure that it is packed with fuel When pellets comes out at the end of the auger the fill feeder should be set back to NO and then directly back to ON to have a full 15 minutes feed of pellets to make sure enough pellets is in the auger Collect the pellets in a bag or container during this 15 minute feed Do not stop the feeding process it is crit
16. protection Yes No SEND A COPY TO EFFECTA gunilla effecta se Effecta AB Vastra R gdalsv gen 21 434 99 Kungsbacka 0300 22320 info effecta se
17. tegrated fuel store model P 11 Calibration of feed rate Integrated fuel store model B Calibration of feed rate Vacuum fed model wel Calibration of feed rate Vacuum fed model PA Calibration of feed rate Vacuum fed model P 15 Calibration of feed rate Vacuum fed model P 16 Controller setup effect output P 17 Controller setup date time Boy Controller setup function test P 18 Back end protection P 19 Heating circuits P 20 Heating circuits P 21 Heating circuits P 22 Documentation Effecta AB V stra R gdalsv gen 21 434 99 Kungsbacka 0300 22320 info effecta se effecta m Check list before electrical power feed Water content Before powering up the system with electrical mains please ensure that all the boiler is filled with water All pumps controlled by the boiler needs to be in water filled heating circuits where there is no blockages from circulation Doors All doors and cleaning accesses needs to be closed and sealed before powering up Flue chimney The boiler must be connected to a approved flue system to evacuate smoke gasses before powe ring up the boiler Fuel feediny Depending on what fuel feed option the boiler is equipped with the fuel feed system needs to be completed before power up as well as the storage filled with pellets When above is confirmed please allow electrical mains to the boiler Effecta AB Vastra R gdalsv gen 21 434 99 Kungsbacka 0300
18. that they very slowly open in the right direction Note that it can be either clockwise or counterclockwise Igniter depending on how the shunt valve has been set up If the MC motor is operating in the wrong direction the power freed Fan phases needs to be switched Compressor Sel lao lle VS Test air clean Convection clean Shunt motor 1 Radiator pump 1 Shunt motor 2 Radiator pump 2 Function test Effecta AB Vastra R gdalsv gen 21 434 99 Kungsbacka 0300 22320 info effecta se E Back end protection Back end protection If one or more heating circuits is connected to the connections at the back of the boiler the back end protection function must be enabled at all times NOTE Warranty is void unless the back end protection function is enabled E Program setup hack end protection Back end protection Press anywhere on the controller and then open the HEA TING SYSTEM menu Depending on what sensors has been connected to the boiler and what program options the system has been set up with the HEATING SYSTEM menu will appear dif ferently The one illustrated is displayed if one sensor G7 is attached and the programmer is set to a constant flow temperature In the shunt control menu scroll down to BACKEND PROT and press OK In the BACKEND PROT menu make sure that the function is set to YES Recommended settings Temp G1 min 60 C Max flow temp 20 C Description of function The first p
19. the fire box and allow the auger to feed in test mode Enter the OPERATION menu and then INSTALLATION menu Activate the FILL FEEDER function which will force feed pellets for 15 minutes Meanwhile the auger is filling up tap the auger repea tedly to ensure that it is packed with fuel When pellets comes out at the end of the auger the fill feeder should be set back to NO and then directly back to ON to have a full 15 minutes feed of pellets to make sure enough pellets is in the auger Collect the pellets in a bag or container during this 15 minute feed Do not stop the feeding process it is critical to have a properly packed and filled auger in order to calibrate the feed rate in the next step A correctly adjusted start dose is one of the most critical and important steps of a comissioning process If the start dose is incorrect it will give the wrong output on the boiler which might create operational issues excessive wear on parts and even be dangerous in extreme situations Q cma Effecta AB Vastra R gdalsv gen 21 434 99 Kungsbacka 0300 22320 info effecta se m Calibration of feed dose Auger version Setting the start dose When the auger is properly packed and full enter the OPERATION menu and open the FEEDER SETTINGS menu and then press RUN START DOSE Collect the pellets being fed during the test start dose process It should be exactly 40cl If it is less increase the amount of seconds of the start dose and run ano
20. ther test It the start dose is greater than 40cl decrease the amount of seconds for the start dose and then run the test start dose again Keep testing until the start dose being fed is exactly 40cl When this step has been processed the boiler is to be reassembled again by putting the fall shaft hose back in to the burner effecta mu Operation settings Burner Fan Feeder settings Temperature set Information Service Installation U VER 3 0 Feeder settings Stetdose 508 Support dose Pellets diameter Run start dose Run supp dose Run oper dose 9 3 o9 9 If the feeder isnt running it is likely that under pressure over the boiler isnt sufficient Make sure that the burner fall shaft is plugged at all time when the black plastic fall hose is out of the burner Effecta AB Vastra Ragdalsvagen 21 434 99 Kungsbacka 0300 22320 info effecta se EAN effecta a m Calibration of feed dose Integrated fuel store version Controller setup Press anywhere on the display and then press the OPE Operation settings Burner RATION icon Fan Operation settings menu Temperature sel Use the and buttons together with OK and the Return Information key to navigate the menu system Service Installation gU 3g 9 Confirm that burner is set to OFF VER 3 0 Feeder menu Enter the FEEDER SETTINGS menu Feeder settings Support dose Pellets diameter Run start dose Change the pel
21. ts and even be dangerous in extreme situations Effecta AB Vastra R gdalsv gen 21 434 99 Kungsbacka 0300 22320 info effecta se effecta effecta m Calibration of feed dose Suction version Filling the internal storage Press anywhere on the display and then press the OPE Operation settings Burner RATION icon i i Feeder settings Operation settings menu Temperature set Use the and buttons together with OK and the Return Information key to navigate the menu system Service Confirm that burner is set to OFF Il Installation menu Enter the INSTALLATION menu Installation Advanced Scroll down to SUCTION SYSTEM and press OK Fill feeder Effect High speed Effect low sepped Suction system menu Testhlow start In the suction system menu scroll down to FILL STORA U 3 o 8 Phase out GE and set the function to ON Fan Pre oper Fan low pre oper The filling process will now begin Clean Phase out Flame Sens NOTE There is a delay time until the vacuum motor co MISCO Lam bda probe mes lt will take 2 3 minutes until the turbine comes on Suction System gt and with a empty storage it can take up to 15 minutes Cascade until it is fully filled Suction system Filling interval O Ah Night blockage On Clean int storage 1 25 h If the feeder isnt running it is likely that under pressure over the boiler isn t sufficient Make sure that the burner fall shaft is plugged at
22. ual weekday Hecommended to use when The building uses radiators or underfloor heating NOTE The outdoor sensor must be placed on a north facing wall to function properly Both If the program BOTH is choosen the shunt motor will regulate the shunt valve to maintain a certain room temperature getting it s reference from the outdoor sensor The temperature to the flow is determined with the help of a heating curve and adjustment in the program This is also known as weather compensation The same outdoor sensor can be used for all three heating circuits running on the same program option The difference between to the program BOTH and the program OUTDOOR is that the room sensor will correct the temperature to the flow with 5 C for every C the room temperature is off Example If a desired room temp is set at 20 C and the actual room temperature is 19 Cthe tem perature to the flow will raise with 5 C until the difference between desired room temperature and the actual room temperature is 0 C The active sensors in this set up is the flow sensor room sensor and the outdoor sensor It is possible to use the ENERGY SAVER function to set back the flow temperature with the desi red amount of C on two different times each individual weekday Hecommended to use when The building uses radiators or underfloor heating NOTE The outdoor sensor must be placed on a north facing wall to function properly the room sensor needs to be placed at a c
23. w speed needs to be set We recommend it to be 50 of the boilers maximum rated output Operation settings Burner Fan Feeder settings Information Service Installation Temperature set Stop temp Start temp Operation settings Burner Fan Feeder settings Temperature set Information Service Installation Fill feeder Effect high speed Effect low speed Testblow start Phase out Fan pre oper Fan low pre oper Never use a higher output than the maximum rated output of the product O Effecta AB Vastra R gdalsv gen 21 434 99 Kungsbacka 0300 22320 info effecta se effecta effecta mu m Program setup date amp time Date amp time Other setti Press OTHER and then open the WEEKDAY menu Time oet the correct date and then press return to get back to Calibr sensors the Other setting menu Function test Alarms Press TIME to open the menu for the clock Set the cor AUR rect local time Start guide E Program setup function test Function test of shunt motors Other settings Press OTHER and then open the FUNCTION TEST menu MAI Time Depending on what functions the boiler have been deli EECIISSEESIESIE vered with a different view will appear in the function test menu Alarms English l l Start guide Test the following functions Shunt motor 1 also 2 and 3 if applicable needs to con trolled so that they open in the right direction Press and check