1. User Manual MANUAL NO 700 283 01D ISSUED MARCH 2006 VERSION 2 00 Contents 2 1 2 2 2 3 2 4 2 5 2 6 2 4 3 4 4 4 5 5 5 1 5 2 6 6 1 6 2 7 7 4 7 2 7 3 7 4 8 9 9 1 9 2 9 3 9 3 1 Introduction to the AP816 s annsnnsnnnnnnnennnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnne 4 Understanding the Keypad Indicators ccssseseeneeeeeee 4 Armed INGIGATOM exits cccet aes verca te a ES 4 Away NGICALOF a irinenn arren tpat 4 Power Indicator soceri ae Gea cee il 4 Ready Indicato 2 2 sccdisctstcepascctasancssceapaceeaidayestedetsstaedealeexesbedencshies 5 ZONE NACIONS 25 cass zee cea eaii aa oiea a T 5 The K ad BUZZEF oo cccececcesceseseseeeeseseecseseseeecseseseceeseeseeseseses 5 Programmable Functions ss ssesssunssunnnnnnnnrnunnnnnnunnnnnnnnnnnnnnnnnnnnn 5 Arming the Control Panel s sssssussunsnnnnensunnnnnunnnnannunnnnnnnnnnennnna 6 Away AMING cerae nre a N NNE 6 Flow to Away Ari c cccecesctessessegecsersneneetegettecnensensenstnasonataueensanenes 6 Quick Away Arm Shortcut Key sssseeeseeseeeeeiesiesreererernserernerneee 6 tay AMING eannan nae a a aaa alanine 7 HOW To Stay Al eyri cect cee eesti venet nrnna ogee ie iriti 7 Quick Stay Arm Shortcut Key ccceceeeceeseeeeeseeeeeeeeeeeeeeeeeeeeeaes 7 How To Stay Arm And GO ececceceeeeeeeeeeeeeeeeeeesaeeseeeeeeeeeeeneeeneeeas 8 Key Switch or Remote Arming cscceceeceeeeeseeeeeseeeeeeeeereeneeeaes 8 PU
2. NUMBER corresponding to the zone you wish to be a STAY zone followed by the key 4 The relevant zone indicator will illuminate po Note Buzz zones will be shown by flashing indicators See Section 11 A Buzz zone cannot be selected as a Stay Zone The Buzz status must be cleared first 5 Repeat step 3 until the selection of stay zones is completed 6 Press the key to exit the stay zone programming mode 10 3 How to Cancel Stay Zones 3 ZONE NUMBER 4 1 Select the required Stay Profile See 10 1 Hold down the 3 key until the keypad buzzer sounds The AWAY indicator will flash to show that the panel is in the Stay Zone programming mode 3 Press the NUMBER corresponding to the STAY zone you wish to cancel followed by the key S00 AP816 USER MANUAL NO 700 283 01D ISSUED MARCH 2006 VER 4 The relevant zone indicator will extinguish 5 Press the key to exit the stay zone programming mode 11 Buzz Zones Violation of a buzz zone when Stay Armed will cause the keypad buzzer to sound for a period of 30 seconds during which time a valid user code must be entered If a valid user code is not entered during this period the system will register an alarm condition This feature helps prevent unnecessary false alarms Note If an entry exit zone is programmed as a buzz zone violation of the entry exit zone when the panel is Stay Armed will cause the keypad buzzer to sound for
3. an intruder It is advisable to choose a code that can be easily remembered by all family or staff members 9 3 5 2 Maids Code 9 3 7 This code may be used to limit access to the premises The Maids code will only disarm the system if the same code was used for arming If armed with a code other than this code the system will view an attempt to disarm using the Maids code as an invalid entry Any valid user code will disarm the system if it has been armed with the Maids code 9 3 5 3 Global Arm Disarm Code This code when entered will either arm or disarm the partitions assigned to that user depending on their status If both partitions are disarmed entering a global code will arm both partitions If both partitions are armed entering a global code will disarm them In the case where one partition is armed and the other disarmed entering a global code at the keypad of the armed partition will disarm that partition and entering a global code at the keypad of the disarmed partition will arm that partition 9 3 8 9 3 6 Option5 Assign User Code to Partitions 1 Enter the User Program Mode as per steps 1 4of 9 2 A gt 2 Press the 5 key followed by the keysto select programmable option 5 The READY and ARMED LEDis will flash simultaneously 3 Enter the USER CODE followed by the key 4 The READY indicator will flash and the AWAY indicator will be illuminated 5 The partitions to which the USER CODE is assigned ar
4. pre The term BYPASS is used to describe a zone which has been de programmed time Should the premises be occupied at the time of activated i e violation of a bypassed zone is ignored and will not auto arming a valid USER CODE entered during the pre arm delay cause an alarm condition will terminate the arming sequence The pre arm delay is signalled by Once the system is armed it is not possible to bypass zones an exit beep All bypassea zones will be automatically cancelled each time the panel is disarmed and must be re bypassed before the next 5 Disarming the Control Panel Ainge Ne 6 1 gt How to Bypass a Zone 51 How to Disarm with a User Code G ue Hold down 9 ZONE NUMBER 1 USER CODE To disarm the system enter followed by a valid USER CODE 1 To enter bypass mode hold down the 9 key for two seconds until the keypad buzzer sounds The Away LED will flash and all 1 Enter the premises through a designated entry route Entering via other LEDis will be extinguished any other route will cause an alarm l 2 Ensure that the panel is not armed Press the number 2 As soon as the entry exit zone is violated the entry delay will corresponding to the zone you need to bypass e g the 2 key if begin The keypad buzzer will sound for the duration of the entry you wish to bypass zone 2 then press the key period 3 The relevant zone indicator will illuminate to indicate that the 4 Once the
5. system disarms the ARMED indicator will extinguish 4 Repeat step 2 to bypass other zones and the keypad buzzer will stop sounding 5 Press the key to exit the bypass mode 5 If no valid user code has been entered prior to the expiry ofthe entry delay period an alarm condition will be registered Note Panic Zones cannot be bypassed 6 Ifthe entry period is too short have your installer change the entry delay period 6 2 How to Un Bypass a Zone Note Ifa strobe or flashing light has been installed and an sees l Hold down 9 ZONE NUMBER alarm condition is registered the strobe will continue flashing enone l PI A after the siren has stopped sounding Entering a valid USER 1 Bypassed zones are shown by constantly illuminated zone CODE will cancel the strobe LEDs 2 Enter bypass mode by holding down the 9 key until the keypad 5 2 How to Disarm using a Key Switch or Remote buzzer sounds The away indicator will flash and the power ready and armed LEDis will be extinguished 1 Activate the remote or keyswitch 3 Press the nimoa corresponding to the currently bypassed zone 2 The system will disarm and the remote indicator if installed will then press the key AP816 USER MANUAL NO 700 283 01 D ISSUED MARCH 2006 VER 2 00 9 AP816 USER MANUAL NO 700 283 01D ISSUED MARCH 2006 VER 10 2 00 4 The zone indicator will extinguish the zone is now active seconds a MEDICAL ALARM condition will
6. the end of the exit delay Quick Away Arm Shortcut Key Hold down the 1 key until the keypad buzzer sounds If this function is enabled it is possible to AWAY arm by simply holding down the 1 key until the keypad buzzer sounds and the arming process begins aa AP816 USER MANUAL NO 700 283 01D ISSUED MARCH 2006 VER Note Ifthe partition is already STAY armed this key will initialise AWAY arming It is therefore possible to change directly from STAY armed to AWAY armed 4 2 Stay Arming Stay arming allows the user to monitor selected perimeter zones and bypass interior zones The user can remain on the premises with access to designated areas during the STAY ARM cycle Any zone which may be violated accidentally should be programmed as a buzz zone When violated a buzz zone will cause the keypad buzzer to sound for thirty 30 seconds before sounding the siren Entering a valid User Code before the siren sounds will silence the keypad buzzer and prevent the siren from sounding To provide greater flexibility the panel caters for the programming of two 2 different STAY PROFILES Each STAY PROFILE contains a unique combination of STAY BUZZ and ALARM zones which cater for a particular STAY ARM requirement Example PROFILE 1 might be used when the family goes to bed in the evening In this profile some interior zones may be programmed as alarm zones or buzz zones whereas PROFILE 2 is utilized while watching television wh
7. the duration of the entry delay time This if the panel is stay armed allows the user to enter the premises and disarm the panel If it is not programmed as a buzz zone the alarm will be triggered immediately If the panel was armed using the 6 key Stay Arm and Go violation of the entry exit zone will always start the entry exit delay 41 1 How to Program a Buzz Zone 4 ZONE NUMBER l Select the required Stay Profile See 10 1 2 Hold down the 4 key until the keypad buzzer sounds The AWAY indicator will flash to show that the panel is ready to program buzz zones 3 Press the NUMBER corresponding to the zone you wish to be a Buzz zone followed by the key 4 The relevant Buzz zone will be shown by the illuminated zone indicator Stay zones will be shown by flashing indicators A Stay zone cannot be selected as a Buzz zone the Stay status must be cleared first 5 Repeat step 3 until all the required Buzz zones are programmed 6 Press the key to exit the buzz programming mode AP816 USER MANUAL NO 700 283 01 D ISSUED MARCH 2006 VER 2 00 23 11 2 How to Cancel a Buzz Zone 4 ZONE NUMBER 1 Select the required Stay Profile See 10 1 2 Hold down the 4 key until the keypad buzzer sounds The AWAY indicator will flash 3 Press the NUMBER corresponding to the BUZZ zone you wish to cancel followed by the key 4 The relevant zone indicator will ext
8. two seconds until the keypad buzzer sounds This is a single key arm function which allows the user to STAY arm and leave the premises If a partition is already stay armed holding down the 6 key initiates an exit delay thus allowing the user to leave the premises without disarming At the end of the exit delay the partition will re arm in the same stay profile it was armed in before the 6 key was held down 1 Hold down the 6 key until the keypad buzzer sounds The keypad buzzer will sound for the duration of the exit delay Only leave via a designated exit route 2 At the end of the exit delay the ARMED indicator will illuminate and the AWAY indicator will remain extinguished All stay zones will be bypassed 4 4 Key Switch or Remote Arming lf fitted 1 Ensure that the READY indicator is illuminated before leaving 2 Leave and close the door remembering to lock 3 Activate the remote or the key switch A remote can be used to Stay Arm or Away Arm 4 The alarm will arm in the away mode Note Ifa remote control is used it is advisable to have the siren 8 AP816 USER MANUAL NO 700 283 01D ISSUED MARCH 2006 VER 2 00 toot on arm function enabled This provides verification that extinguish If the siren toot on disarm option is enabled the siren the system has armed will provide a double toot when the panel is disarmed 4 5 Auto Arming 6 Bypassing Zones The panel may be programmed to arm automatically at a
9. 2 available user code slots Allows editing of the user code properties for a selected user 9pton 4 cod This is a bit mapped menu Allows the allocation of a selected user code to a designated Option S artition s This is a bitmapped menu Option 8 Adding User Remotes Option 9 Deleting a User Code Allows the deletion of a user code using the user code slot Savona number Option 11 Allows viewing of a user name if the slot number is known 9 2 How to Enter the User Program Mode PON gt 6 Ensure that the panel is not armed Hold down the key until the keypad buzzer sounds The ARMED and READY indicators will flash alternately Enter a MASTER USER CODE The factory default is 1234 Should the MASTER USER CODE be defaulted to six digits it will be 123456 Press the key A valid entry will be confirmed by along beep If steps 1 4 are performed correctly the READY indicator will flash If an invalid code was entered the keypad buzzer will give an error beep 3 short beeps If the error beep occurs press the key this clears all previous entries and repeat steps 2 5 Select a programmable option from Table 1 above Example To add a new user code enter User Program Mode by completing steps 2 6 as listed above To access Option 0 enter a value of 0 See table 1 followed by Enter a NEW USER CODE followed by the key Once the user co
10. Deletingi the code in slot one will reprogram it to 1234 4 Further codes may be deleted by repeating Step 3 above 5 After deleting the final code press the key to exit User Program Mode Option 10 Delete a User Code Slot known a Enter the User Program Mode as per steps 1 4 of 9 2 2 Press the 1 key then the 0 key followed by the key The ARMED and READY indicators will flash AP816 USER MANUAL NO 700 283 01D ISSUED MARCH 2006 VER simultaneously 3 Enter the SLOT NUMBER for the User Code you wish to delete followed by the key You can determine the slot number of a particular code by using programmable option 3 4 Further User Codes may be deleted by repeating Step 3 5 After deleting the final code press the key to exit User Program Mode 9 3 10 Option 11 Viewing a User Name Slot Known LCD Keypad only 1 Enter the User Program Mode as per steps 1 4 of 9 2 2 Press the 1 key then the 1 key followed by the key 3 Enter the SLOT NUMBER followed by the key 4 The USER NAME will be displayed Default names are displayed as the SLOT NUMBER i e If the SLOT NUMBER has not been edited as per Option 1 5 Press to exit User Program Mode 10 Stay Zones Stay zones are those zones which are bypassed automatically when the system is iSTAY ARMEDi To avoid triggering the alarm zones such as bedrooms which are protected by Passive Infra Red PIR det
11. E until the keypad beeps 2 Press 1 followed by the partition number If no key is pressed on the keypad for 20 seconds it will beep and default back to itis original partition The keypads may be programmed to remain in the new partition On the AP 816 Alarm Panel PARTITION limited to 1 or 2 ZONE limited to 1 16 OUTPUT limited to 1 7 Any value outside of these constraints will result in a key entry error occuring aoe AP816 USER MANUAL NO 700 283 01D ISSUED MARCH 2006 VER 15 Remote Telephone Access Please note that this section is only relevant if programmed by your installer The AP 816 Alarm Panel has a secure remote telephone interface which allows a user to arm disarm to bypass unbypass zones and to set programmable outputs via a phone line A user accesses the remote dial in interface by dialling the alarm panel using a DTMF phone This programmable function is only available if enabled by your installer To access the remote dial in interface dial the alarm panel and wait the number of rings programmed the default number of rings being 15 If the fax defeat function has been enabled dial the panel and hang up after one ring Dial in again within 1 minute the panel will pickup immediately and transmit handshake tones consisting of a high pitch tone for two seconds followed by a lower pitch tone for one second Within twenty seconds of the panel transmitting the handshake tones enter a v
12. NUAL NO 700 283 01D ISSUED MARCH 2006 VER Reading Zone Indicators Reading of the value as indicated by the Zone LEDis is achieved by summing the numbers as represented by the zone indicators The representative value of each zone indicator is shown in Table 2 below Table 2 Values Represented by Each Zone Indicator Values shown by indicators are indicative of single unit values whilst values shown by Zones 5 8 are indicative of tens of units Example Assume zone indicators 1 2 and 5 are illuminated Units are represented by the sum of Zone 1 and Zone 2 i e 1 2 and tens of units are represented by the value of Zone 5 i e 1 Thus the value indicated by the illuminated LED will be as shown as in the example below Zone 2 2 Sum of Sum of Zone Zone LED 3 LED 1 Indicators Indicators Thus the value of the illuminated zones is 13 9 3 5 Option 4 User Code Properties Press Master Code 4 User Code PROPERTY NUMBER 1 Enter the User Program Mode as per steps 1 4 of Section 9 2 AP816 USER MANUAL NO 700 283 011 D ISSUED MARCH 2006 VER 2 00 17 2 Press the 4 key followed by the key to select programmable option 4 The READY and ARMED indicators will flash simultaneously 3 Enter the USER CODE followed by the key 4 The READY indicator will flash and the AWAY indicator will be illuminated 5 The properties as
13. TO AMING ere eae geese cen 9 Disarming the Control Panel ccsecsecseeseeseseteeseneeseeneeeees 9 How To Disarm with a User Code 00 0 eeceeceeseeeeeeeeeeeeeeeeneeeees 9 How To Disarm using a Key Switch or Remote ceeeeee 9 Bypassing ZONES cccseeeseeeeseeeeseeeseeeeneeeenseeesseeeneeeensneenseenenees 10 How To Bypass a ZOMG sisiuks asaru 10 How To Un Bypass a ZONG eisni ena 10 Emergency Alarm ccccsscsssseesseesssenenseeesseessseeeseeeaseeeesenensee 11 Fire Alarm S avast keel Aa E a 11 Pa ic ALANIS pisia annei gees cenecescergstbeasnetancecruanceseetanss 11 Medical AlanimS sceriescc cscs cieshanetecccenceeieevsasiedinenstecnaatnciiieen E 12 Duress Alarms 3 2 cci sick eicditieestes an iaiaaeaia aaaea Taaak 12 Alarm MGMONY ssesisscictvisccscctecesadessendeaccesnteasneseeniensnandsiceeencnessesds 12 User CODCS saciccesteccehectcieccctenceaste evciadedeenchetueasyetisccysiecdedentcatsiue 13 Adding Deleting and Editing User Codes cccceee 13 How to Enter the User Program Mode ecceeseeeereeeneeees 14 Explanation of Programmable Options eeeeeeeeeeeenees 15 Option 0 Add a New User Code ceetceeeeeeees 15 2 AP816 USER MANUAL NO 700 283 01D ISSUED MARCH 2006 VER 2 00 9 3 2 Option 1 Edit a User Name 0 0 ceeeceeceeeeeeeeseeeeeeeeeeeeeeereeeee 15 9 3 3 Option 2 Edit a Selected User Code c cccceeeseeeeteeeeneeees 16 9 3 4 Option 3 View
14. a User Clode Slot Number c cee 16 9 3 5 Option 4 User Code Properties eceeeeeeeeeeeeeeeseeeeeenreees 17 9 3 5 1 Explanation of User Code Properties Duress Code 18 9 3 5 2 Maids Code jit ccthe iii dese elcid isi ed ade ee 19 9 3 5 3 Global Arm Disarm Code ccecceseeseeceeeeeeeeeeeeeeeeeeeeeeneeeaees 19 9 3 6 Option 5 Assign User Code to Partitions cceceeeeee 19 9 3 7 Option 8 Adding User Remotes ceccecceeceeeeeeeeereeeeenteees 20 9 3 8 Option 9 Delete User Code Code known eceeceeeeee 20 9 3 9 Option 10 Delete a User Code Slot Known eceeeeeeees 20 9 3 10 Option 11 Viewing a User Name cceeceeseeeeeeeeeeeteeeeeenees 20 10 Stay ZONES cesinccesiseieccseccecseveitinesetsccannee niesie unnin srs nessis 21 10 1 How To Select a Stay Profile ec eceeeeeeeeeeeeeseeeeeeeneeeeeeenees 21 10 2 How To Program Stay ZONES cescceceeeeseeeeteeeseeeeeeeseeteeetees 22 10 3 How To Cancel Stay ZONES cceeceeseececeeeeneeeeeeeeeteeeeneeeeetaees 22 11 BUZZ ZONES ccseseeeseeeeeeeeseeeeneeeeneeeeseeeeneeeeeseesneneeneeeeneneeseeeenoneenen 22 11 1 How To Program a BUZZ ZOMG c cesceeeeseeeeeeeeeeeeeeeeeseneeeeee 23 11 2 How To Cancel a BUZZ ZOMG eeceeeeeeeeeeeeeeeeeeeeeeeeteeeeneeeeens 23 12 Chime ZONES 5 sess daca ase cascade cee ctl vests cece eccnccx veceaatyecevsneeeenyee 24 12 1 How To Program Chime Zones c
15. alid user code on the DTMF enabled phone If a user code is not entered or if the user code is invalid the panel will release the line If the user code is valid and telephone access has been enabled the panel will give a single confirmation beep indicating that the user has gained access to the remote interface If no key presses are detected for twenty seconds once access has been gained to the gt remote interface the panel will release the line Should the panel be programmed to report to your cellulartelephone entering the user code in the delay between beeps will also allow access to the remote telephone interface If the phone in access has been setup to arm disarm only pressing the number of the partition allows the user to toggle the panels arm status A single beep indicates that the partition has armed a double beep indicates that the partion has disarmed 3 beeps indicates that the partition is not ready to arm AP816 USER MANUAL NO 700 283 01 D ISSUED MARCH 2006 VER 2 00 2T Table 5 Remote Telephone Operation Operation Key Entry Panel Response Arm a Partition 1 1 PARTITION A Single Confirmation Beep indicates Partition armed successfully Three Error Beeps indicates Partition cannot be armed by user code or Partition not ready to be armed or a key entry error has occured Disarm a Partition 1 2 PARTITION A Single Confirmation Beep indicates Partition disarmed s
16. be activated 5 Press the key to exit the bypass mode The keypad buzzer will beep 5 times A medical reporting code will be reported to the monitoring 7 Emergency Alarms company 7 4 Duress Alarms 7 1 Fire Alarms DURESS CODE F Hold down the F key for two seconds until the keypad buzzer sounds This is a special user code which should only be used in the unique situation where an intruder forces one to disarm the If the F key is pressed until the keypad beeps approximately 2 system inder duress seconds a FIRE ALARM condition will be activated When amp DURESS CODE is entered the control panel disarms The FIRE ALARM CONDITION may also be triggered by a smoke Normally however a Duress Alarm Code if programmed will be detector connected to an appropriately programmed zone reported to the monitoring company The siren will sound on and off repeatedly if programmed and the It is advisable to choose a Duress code which can be easily FIRE REPORTING CODE will be transmitted to the monitoring remembered by all family or staff members company To silence the siren enter a valid USER CODE 8 Alarm Memory 7 2 Panic Alarms The Alarm Memory displays any zones which were violated or bypassed during the last arm cycle A flashing ARMED indicator P notifies the user of an alarm memory condition To view the alarm Hold down the P key for two seconds until the keypad buzzer sounds memory disar
17. cceeeeceeeteeeeeeteeeeeeeeeeteeeees 24 12 2 How To Cancel Chime Zones cccseeeseeeeeeeeeeeeeneeeneeeeeeenees 25 13 Viewing Trouble Conditions csccsceeseeseeseenseenseeeeeeeeeee 25 14 Changing ia Partition siciiicesccesideecestcceccsaxtede ensetcceseseiceeedeg eee 26 15 Remote Telephone ACCESS sscessssseceseseseeeeshalcebeseneeeaes 27 16 Output Control via a Keypad ccecssesseeng hsv eeeeseneeeseeeneeees 29 Tables Table 1 User Progamming Options c ceceeeeeeeereeeeeeeeeeneeeeeeeeeeeens 14 Table 2 Values Represented by each Zone Indicator ceeee 17 Table 3 User Code Properties 0 ceceecsseeseeeseeeeeeeeeeieesaeeeaeeeeeeneeteee 18 Table 4 Trouble Conditions 0 eeeeeceeceeeeeeeeeeeeeeeeeeeeeeeeseeeaeeeeeeeeeneee 26 Table 5 Remote Telephone Operation ecceeceeseeseeteeeeeeeeeneeeeees 29 AP816 USER MANUAL NO 700 283 01 D ISSUED MARCH 2006 VER 2 00 3 is Introduction to the AP 816 The AP816 is a versatile microprocessor based eight zone alarm panel It provides for two partitions and can be expanded to sixteen zones Since most features are programmable please check with your installer as to which options have been enabled There are eight programmable burglary zones a monitored siren auxiliary power and five programmable outputs which may be programmed to perform various trigger switching functions For correct operation the AP816 must be used with the sp
18. de 4 Global Arm Disarm Code Allocate a User Code Master Code 5 User Code to a Partition Partition Number Teach a Remote to a Master Code 8 User Code User Code Press Tx Button Delete User Code by Master Code 9 User Code Code Delete User Code by Master Code 10 Slot Number Slot Number Change Partitions Mode 1 Partition Number Select a Stay Profile Mode 2 Profile Number Program Cancel 3 Zone Number Stay Zone Program Cancel 4 Zone Number Buzz Zone Program Cancel 2 Zone Number Chime Zone Stay Arm and Go Bypassing Un 9 Zone Number Bypassing a Zone Alarm Memory 0 Displays zones violated 02 Displays zones bypassed View Trouble 7 1 AC Mains fail 2 No Communication Condtions 3 Phore Line 4 Siren Tamper 30 2 00 5 Low Battery 6 Loss of clock timer 7 Engineer Reset 8 Box Tamper 10 Tamper on Peripheral 11 Comms failure to peripheral device 12 Loss of power to peripheral device AP816 USER MANUAL NO 700 283 01D ISSUED MARCH 2006 VER
19. de is programmed enter the next code followed by To exit the program mode press the key 14 AP816 USER MANUAL NO 700 283 01D ISSUED MARCH 2006 VER 2 00 For a full list of options refer to Table 1 Programming of these options is explained below 9 3 Explanation of Programmable Options 9 3 1 Option 0 Add a New User Code Hold Master Code 0 New Code 1 Enter the User Program Mode as per steps 1 4 of 9 2 2 Press the 0 key followed by the key to select the programmable option 0 The Ready and Armed indicators will flash simultaneously 3 Enter the NEW USER CODE followed by the key 4 Further codes may be added by repeating step 3 above 5 After entering the last code press the key to exit the user program mode 6 When a new user code is added it is stored in the first available user slot 9 3 2 Option 1 Edit a User Name LCD Keypads only Hold Master Code 1 User Code 1 2 Enter the User Program Mode as per steps 1 4 of 9 2 Press the 1 key followed by the key to Select programmable option 1 The Armed indicator will flash Enter the USER CODE of the User whose name you wish to edit User Names are displayed as the User Slot Number by default Edit the User Number so that it reads the correct User Name To confirm the entry press The MODE key can be used to move the cursor to the ri
20. e displayed by the by the zone LEDis If zone LED 1 is illuminated the User Code can arm or disarm partition 1 If zone LED 2 is illuminated the User Code can arm or disarm partition 2 It is possible to program codes to arm disarm both partitions 9 3 9 AP816 USER MANUAL NO 700 283 01 D ISSUED MARCH 2006 VER 2 00 19 ane 6 To select which partitions the USER CODE may arm or disarm toggle zone LEDis by entering the ZONE LED NUMBER followed by the key T Repeat step 6 until the User Code has been assigned to the correct partition s 8 Press the key to exit User Program Mode Option 8 Adding User Remotes T Enter the User Program Mode as per steps 1 4 of 9 2 2 Press the 8 key followed by the key to select programmable option 8 The READY and ARMED A LEDis will flash simultaneously 3 Enter the USER CODE followed by the key 4 The READY indicator will flash and the AWAY indicator will be illuminated 5 Press any button on the new remote This will assign the new remote to the user code as entered in Step 3 6 To add additional remotes repeat steps 3 5 7 Press the key to exit User Program Mode Option 9 Delete User Code Code known i Enter the User Program Mode as per steps 1 4 of 9 2 2 Press the 9 key followed by the key to select Menu option 9 The READY and ARMED indicators will flash simultaneously 3 Enter the USER CODE to be deleted followed by the key 6
21. ecified transformer battery combination and appropriate peripheral sensors and signalling devices 2e Understanding the Keypad Indicators Refer to the illustration on the inside front cover of this manual 2 1 ARMED Indicator Red lluminated System Armed Extinguished System Disarmed Flashing Alarm Condition or Memory 2 2 AWAY Indicator Red Illuminated System Armed in Away Mode Extinguished System Disarmed Armed in Stay Mode 2 3 POWER Indicator Red lluminated Mains Power is present Flashing Trouble Condition 2 4 READY Indicator Green llluminated System is ready to be armed 200 AP816 USER MANUAL NO 700 283 01D ISSUED MARCH 2006 VER 2 5 ZONE Indicators Yellow llluminated Zone bypassed Extinguished Zone clear Flashing Zone violated or tampered 2 6 The Keypad Buzzer The AP816 keypad includes a buzzer which is used for audible signaling and verification of certain keypad functions There are 4 possible volume settings loud medium soft and silent The default value being loud To program the keypad volume use the following table Key Entry Keypad Buzzer Options 3 Loud 2 Medium 1 Soft 0 Silent To change the the volume for this example to soft press the Jand 1 key simultaneously for 2 seconds long press After a 2 second time lapse the keypad will respond w
22. ectors or windows which may be opened must be bypassed when istaying at homei Stay zones need only be programmed Orce Each time the system is armed in the Stay Mode the pre selected stay zones will be bypassed automatically The panel allows for two unique STAY PROFILES to be stored ASTAY PROFILE stores a pre selected combination of STAY and BUZZ zones to suit a specific STAY ARM requirement If a partition is stay armed using Profile one it is possible to toggle the panel arm status directly to stay arm profile 2 by holding the 5 key for two seconds STAY and BUZZ zones can be programmed for each profile once the profile has been selected See section 10 and 11 AP816 USER MANUAL NO 700 283 01 D ISSUED MARCH 2006 VER 2 00 21 10 1 How to Select a Stay Profile MODE 2 PROFILE NUMBER Press the key to clear any previous entries Hold MODE down for one second until the keypad beeps Press the 2 key followed by the key Press 1 or 2 for the required profile Press to enter The buzzer will give a long beep Program STAYand BUZZ zones for the profile or ARM the profile Se sections 10 and 11 oOaPwNn gt 10 2 How to Program Stay Zones 3 ZONE NUMBER Select the required stay profile See 10 1 Hold down the 3 key until the keypad buzzer sounds The AWAY indicator will flash indicating that the panel is in the Stay Zone programming mode 3 Press the
23. en all interior zones would be bypassed See 10 1 How to Select a Stay Profile How to Stay Arm USER CODE Do not leave premises _ Select the required STAY PROFILE See Section 10 1 2 Ensure that the READY indicator is illuminated If not check that all protected doors and windows are closed and that all movement has ceased in the areas covered by motion detectors 3 Press the key 4 Enter a valid USER CODE If an incorrect code is entered the keypad will give an error beep In the event of an error press the key and re enter the USER CODE 5 DONOT violate the entry exit zone normaly the front door If the AP816 USER MANUAL NO 700 283 01 D ISSUED MARCH 2006 VER 2 00 7 entry exit zone is violated the system will arm in the AWAY mode 6 The ARMED indicator will illuminate and the keypad buzzer will sound for the duration of the exit delay 7 Upon expiry of the exit delay the AWAY indicator will remain extinguished 8 Any STAY zones will be automatically bypassed indicated by a steadily illuminated indicator 9 Ensure that you enter only those areas that are bypassed Quick Stay Arm Shortcut Key hold down the 5 key for 2 seconds untill the keypad buzzer sounds It is possible to STAY arm by holding down the 5 key until the keypad buzzer sounds The panel will immediately arm into the stay mode without any exit delay a3 How to Stay Arm and Go Hold down the 6 key for
24. ght whilst the F key can be used to move from right to left Further codes may be edited by repeating steps 3 4 above AP816 USER MANUAL NO 700 283 01 D ISSUED MARCH 2006 VER 2 00 15 9 3 3 Option 2 Edit a Selected User Code Hold Master Code 2 Old Code New Code 1 2 9 3 4 Option 3 Enter the User Program Mode as per steps 1 4 of 9 2 Press the 2 key followed by the key to select programmable option 2 The READY and AArmed indicators will flash simultaneously Enter the USER CODE which is to be edited followed by the key The READY indicator will flash and the AWAY indicator will be illuminated Enter the NEW CODE followed by the key The READY and ARMED indicators will flash simultaneously To edit other codes repeat steps 3 5 Press the key to exit the User Program Mode View a User Code Slot Number Hold Master Code 3 User Code r 16 2 00 Enter the User Program Mode as per steps 1 4 of 9 2 Press the 3 key followed by the key to select programmable option 3 The READY and ARMED indicators will flash simultaneously Enter the User Code followed by the key The READY indicator will flash and the AWAY indicator will be iluminated The USER CODE slot number will be displayed by the Zone indicators See table 2 Press the key to exit the User Program Mode AP816 USER MA
25. hich contains a pre programmed 4 digit code of 1234 The alarm panel may have been programmed by your installer to have 1 or 2 partitions A partition is a group of zones which may be armed and disarmed independantly without affecting zones or users assigned to other partitions i e a guest cottage appended to a main house may be partition 2 The main house being partition 1 Note User codes may be 4 default or 6 digits long This is a programmable feature Check with your installer to verify which option has been programmed 9 1 Adding Deleting and Editing User codes Hold MASTER USER CODE PROGRAMMABLE OPTION The AP 816 utilizes a user friendly programmable interface which allows the user to add modify or delete user codes See Table 1 for a summary of programmable options The programmable interface is accessed by entering the USER PROGRAMMING MODE AP816 USER MANUAL NO 700 283 01 D ISSUED MARCH 2006 VER 2 00 13 Table 1 User Programming Options Options Summary of Programmable Options Option O Allows for the addition of new user codes Allows editing of the user name displayed by LCD keypads Option This menu is only applicable if LCD keypads are installed Allows editing of a selected user code Note that the user code Option 2 properties are not edited only the user code itself Allows viewing of the user code slot number for a selected code Option 3 There are 3
26. inguish 5 Press the key to exit the buzz zone programming mode 12 Chime Zones The chime mode allows the user to monitor nominated zones while the system is disarmed The keypad buzzer will sound briefly when the nominated zone is violated the siren will NOT sound and no alarm condition will be reported EXAMPLE If you wish to know each time someone enters or exits the front door of your office program this zone as a chime zone the keypad will beep each time someone opens the front door 12 1 How to Program Chime Zones 2 ZONE NUMBER 1 Hold down the 2 key until the keypad buzzer sounds The AWAY indicator will flash 3 To program a zone as a chime zone press the key corresponding to that zone followed by the key The zone indicator will illuminate 4 Program any other zones you wish to select as chime zones as per step 3 5 Press the key to exit the chime programming mode ae AP816 USER MANUAL NO 700 283 01D ISSUED MARCH 2006 VER 12 2 How to Cancel Chime Zones 2 ZONE NUMBER _ Hold down the 2 key until the keypad buzzer sounds 2 The AWAY indicator will flash 3 To cancel any chime zones press the key corresponding to that zone followed by the key The zone indicator will extinguish 4 Press the key to exit the chime programming mode 13 Viewing Trouble Conditions Hold down the 7 key for two seconds until the keypad b
27. ith a beep at the new volume setting For the silent setting no response will be heard This is a keypad specific setting All zones programmed as Chime or Buzz Zones will sound with a loud buzz regardless of the keypad volume set above 3 Programmable Functions 2 Functions include Quick Away Arm Quick Stay Arm Arm with Entry Exit or Follower Zones Violated Stay Arm Stay Arm and Go AP816 USER MANUAL NO 700 283 01 D ISSUED MARCH 2006 VER 2 00 5 Forced Arm Push to Arm Siren Sound on Arm Disarm single toot arm double toot disarm Panic Alarm Fire Alarm Chime Zones Buzz Zones Zone Tamper Arm with Key Switch or Remote Control 4 Arming the Control Panel 4 10 Away Arming How to Away Arm USER CODE Leave via Entry Exit Zone 1 Ensure that the READY indicator is illuminated If not check that all protected doors and windows are closed and that all movement has ceased in areas covered by motion detectors If necessary close the front door 2 Press the key 3 Enter a valid USER CODE If an incorrect code is entered the keypad buzzer will beep three times In the event of an error press the key and re enter the code 4 The ARMED indicator will illuminate and the keypad buzzer will sound for the duration of the exit delay Any bypassed zones will be indicated by a steady illuminated zone indicator 5 Leave only via a designated exit route The panel will arm at
28. m the panel and continue as follows If the P key is pressed until the keypad beeps approximately 2 0 seconds a PANIC ALARM condition will be activated APANIC ALARM may also be activated using any FIXED PANIC Hold down the 0 key for two seconds until the keypad buzzer sounds button or a REMOTE PANIC button if installed 1 Hold down 0 until the keypad buzzer sounds If the audible panic option has been selected the sir n will sound 2 The READY and POWER indicators will extinguish and the A PANIC ALARM will be transmitted to the monitoring company keypad buzzer will sound briefly To silence the siren enter a valid USER CODE 3 Illuminated zone indicators show which zones were violated Press the P key only in an emergency situation which requires during the last armed period response by emergency personnel Press 2 to display zones which were bypassed Press 3 to display which zones were tampered 7 3 Medical Alarms Press 1 to return to violated zones AP816 USER MANUAL NO 700 283 01 D ISSUED MARCH 2006 VER 2 00 11 NOOR The alarm memory is erased at the beginning of each arm cycle M Hold down the M key for two seconds until the keypad buzzer sounds If the M key is pressed until the keypad beeps approximately 2 A AP816 USER MANUAL NO 700 283 01D ISSUED MARCH 2006 VER 9 User Codes The AP 816 Alarm Panel has 32 programmable user codes By default user code 1 is the Master User Code w
29. mable Output Status 3 3 OUTPUT A Double Beep indicates that the programmable output is clear Three Error Beeps indicates that a key entry error has occured Hang Up 0 Telephone Line Released Three Error Beeps indicates that a key entry error has occured ae AP816 USER MANUAL NO 700 283 01D ISSUED MARCH 2006 VER 16 Output Control via a Keypad If the panel has been setup to control switching functions via itis outputs these can be controlled via the keypad e g turning lights on and off Hold down the MODE key and press 3 Any outputs that are currently set ON will be shown as an illuminated zone indicator To toggle the output status enter OUTPUT NUMBER followed by Press to exit User Program Mode Ensure that you have checked with your installer which outputs are used for radio reporting so as to prevent the triggering of false alarms AP816 USER MANUAL NO 700 283 01 D ISSUED MARCH 2006 VER 2 00 29 User Guide Quick Refernece Add a User Code Master Code 0 New Code Change a User Code Master Code 2 Old Code New Code View a Slot Number Master Code 3 User Code View the Slot number via the zone LED s Edit User Code Master Code 4 User Code Properties 2 or 3 or 4 2 Duress 3 Arm to Disarm Co
30. signed to the USER CODE are displayed by the Zone indicators An illuminated LED s indicates that certain property ies have been assigned to the USER CODE Refer to Table 4 fora list of USER CODE properties 6 To select a user code property press the key which corresponds to that property followed by the key The appropriate zone LED will illuminate To deselect a property press the corresponding key followed by the key and the LED will be extinguished Example To enable a User Code to function as a duress code press the 2 key followed by the key The zone 2 LED will illuminate to confirm the selection T Repeat step 6 until the desired properties have been programmed 8 Press the key to exit the User Program Mode Table 3 User Code Properties Zone LED Property 2 Duress Code 3 Arm to Disarm Code Maids Code 4 Global Arm Disarm Code Explanation of User Code Properties 9 3 5 1 Duress Code This is a special 4 default or 6 digit user code check the code length with your installer which should only be used in the unique situation where an intruder forces one to disarm the system under duressi When the DURESS CODE is entered the control panel disarms 18 AP816 USER MANUAL NO 700 283 01D ISSUED MARCH 2006 VER 2 00 normally however a DURESS REPORTING CODE is trans mitted to the monitoring company to inform them that you have been forced to disarm the control panel by
31. uccessfully Three Error Beeps indicates Partition cannot be disarmed by user code or a key entry error has occured Check Arm Status By Rartition 1 3 PARTITION A Single Beep indicates Partition is Armed A Double Beep indicates partition is Disarmed Three Error Beeps indicates a key entry error Bypass a Zone 2 1 ZONE A Single Confirmation Beep indicates that the zone was successfully bypassed Three Error Beeps indicates that the zone cannot by bypassed or a key entry error has occured A Single Confirmation Beep indicates that the zone was successfully unbypassed Un Bypass a Zone 2 2 ZONE yp 2 2 1r Three Error Beeps indicates that a key entry error has occured A Single Beep indicates that the zone is bypassed Check Zone a A Double Beep indicates that the zone is un 2 3 ZONE p Bypass Status bypassed Three Error Beeps indicates that a key entry error has occured Set Programmable 3 1 OUTPUT A Single Confirmation Beep indicates that the programmable output was set Output Three Error Beeps indicates that a key entry error has occures A Single Confirmation Beep indicates that Clear the programmable output is clear Programmable 3 2 OUTPUT ah Output Three Error Beeps indicates that a key entry error has occured A single Beep indicates that the programmable output is set Test Program
32. uzzer sounds The user is alerted to a trouble condition via a flashing power LED It is also possible to enable a trouble beep If the trouble beep has been enabled the keypad buzzer will sound to alert the user that a trouble condition has occured Press the key to silence the buzzer Hold down the 7 key for two seconds The ARMED AWAY and READY indicators will flashing simultaneously showing that the keypad is in the TROUBLE VIEW MODE Refer to the table 5 below to find the significance of each illuminated zone LED The system will automatically exit the TROUBLE VIEWING MODE after one minute Alternately to exit this mode press Note Certain trouble conditions will only clear once the trouble condition has restored To cancel the beeping without viewing the trouble conditions press key AP816 USER MANUAL NO 700 283 01 D ISSUED MARCH 2006 VER 2 00 25 Table 4 Trouble Conditions Indicator Trouble Condition 1 AC Mains Failure Failure to communicate successfully to monitoring company Phone line trouble Siren tamper Low battery Loss of Clock Timer Engineer Reset Box tamper O47 CO N OD AIAJ Ww Pp n a oO Tamper on peripheral device i Communication loss to peripheral device mi ine Loss of power to peripheral devices 14 Changing a Partition To change partitions the keypad must be a global keypad 1 Hold MOD