Home
AME BME Series User Manual rev may11
Contents
1. repair during warranty will have no cost to customer excluding machine transportation or technician displacement when required which will run at customer s expenses Repair under warranty does not cover emission of certificates of calibration even in cases in which machine or accessories were purchased with a certificate of calibration Results generated by this machine are calculated based on testing standards and general knowledge on mechanical properties of materials The manufacturer will not supply testings from third parties aiming to validate results The manufacturer will indicate on request a reference laboratory for this purpose which will be contracted exclusively at customer s expense The customer acknowledges the need to contract specific insurance covering any risk associated to the use of testing results generated The manufacturer will under no circumstance be held responsible for losses damages lost profits or revenue bodily injury including permanent disability paralysis and death arising out of the use of the machine 13
2. testings but also cyclic and creep testings complying with a wide range of testing standards Detailed information about software commands are found in DynaView Reference Manual which is installed in DynaView folder in pdf format and can be reached at Start gt Programs gt DynaView menu External dimensions 1 AME standard crosshead travel ri al al O hey Cn ve wa 16 tina ei rew des re dater waht Onna meteria 09 1 1 18 01 08 34 8kg Fizoia 2 AME extended crosshead travel Lo my SHO AME Series extended Y crosshead travel drawing 1 date weight Oswaldo materia _ 17 55 01 08 528kg Filizola 10 3 BME Description units scale resp Testing Machines rev drawing E date weight Oswaldo mater 00 1 1 05 05 08 688 Filizola A 4 Y BME Series Universal 5 11 Technical specifications Universal Testing Machine External parts carbon steel with synthetic painting oe ee ball screw with system preloaded nut Protection degree IPOO Capacity according to model 5 to 500 0 5mm min Power supply universal full range 93 to 135Vac or 187 to 250Vac 47 to 63Hz 90W max temperature temperature 12 Warranty and Limited Liability Agreement This universal testing machine and accessories is warranted for 1 year from commercial invoice date against any defect excluding defects caused by misuse or normal wear Any
3. T cnica Industrial Oswaldo Filizola Ltda User Manual AME BME Series Universal Testing Machines rev may 11 Index Safety precautions Machine Control sccsseeeeseeees External dimensions Technical specifications Warranty and Limited Liability Agreement Limpas samurais ot Introduction T cnica Industrial Oswaldo Filizola Ltda thanks you for the purchase of this product This machine was designed to be a reliable tool for mechanical testings presenting a long maintenance free service life Please feel free to contact us at any moment This universal testing machine is used for tensile compressive flexural and other testings according to the grips and accessories supplied Its motion system is based on precision ball screw and a motor driver set totally controlled by DynaView Standard Pro M Software allowing simple and efficient compliance with many testing standards ISO ASTM DIN etc of many materials plastics metals rubber etc Setup This machine must be installed on a table or workbench away from humidity or direct sunlight It must be installed close to the computer which will control it It must be connected to a power outlet ranging from 93 to 135Vac or 187 to 250Vac 47 to 63Hz universal full range supply with minimum rated power 0 1kVA The serial cable DB9F connector must be connected to a PC serial port or a serial adapter Conn
4. ease Reinsert the cap after lubrication This lubrication must be done every 6 months or in smaller intervals Scheduled maintenance A scheduled maintenance must be done every 3 years It consists of a disassembly of machine in which all mechanical parts are cleaned and_ lubricated Scheduled maintenances increase the service life of mechanical parts motor and driver If machine is exposed to excessive dirt during usage an yearly maintenance is recommended Maintenance of this product can N WARNING be performed only by factory trained personnel Safety precautions The machine crosshead can exert forces equal to or greater than rated capacity specified in kN in the upward or downward direction According to machine model this force may be considerably higher than rated capacity The crosshead may cause hazards to user who can have his hand or other body part trapped by machine resulting in serious physical hazards or death Every machine has an emergency stop button which will immediately cease any crosshead movement Every user must be trained to properly use the emergency stop button prior to machine usage Accidents with machine can result N DANGER in serious physical hazards or death Machine control This universal testing machine is totally controlled by DynaView Standard Pro M software This software features powerful motion control resources which allow not only tensile bending compressive and flexural
5. ection to power outlet N WARNING outside the specification may severely damage the machine Parts description Main machine parts are the following 1 On off button must be pressed to turn on the machine When pressed a lamp inside the button will light indicating the machine is ready 2 Safety emergency stop button must be pressed to stop the machine in emergency situations To restore machine functions turn the button clockwise until it is unlocked 3 Crosshead where load cell and or grip accessory is fixed This part can exert forces equal to or greater than machine rated capacity specified in kN in the upward or downward direction 4 Upper head part where load cell and grip may be optionally fixed 5 6 Upper and lower end of travels must be used to limit crosshead movement e g to avoid collision between grips 7 Serial cable and supply conductor Maintenance Maintenance of this product must be performed only by factory trained personnel Changes to driver settings or motor replacement may damage both of them If customer is instructed by factory to make any kind of maintenance power plug must be disconnected from power outlet before that In case of any maintenance need please get in contact with manufacturer The machine ball screw must be periodically lubricated This lubrication is done by removing the ball screw nut lubrication hole cap and applying lithium based grease e g blue gr
Download Pdf Manuals
Related Search
Related Contents
Skross SKR1500211 Returnstar PC E-Lock Family Flagship V9.0 User Manual Technical Analysis User's guide AEP20-009 AEP20TOP9 - Linkcare Gate Automation Enermax VOLCANUS 取扱説明書 MAIB Control User Manual - pei tel Communications GmbH Bedienungsanleitung ACDSee Pro 3 Handbuch Air-Conditioners Copyright © All rights reserved.