Home

The information in this User Manual has been

image

Contents

1. 11 3 1 Network Configuration eret tetro rette rore oe aereo i Eor E E SEES EEE 11 3 2 Gateway Subnet Protection 12 3 3 Wireless COMPGULATION ssiscsssiesisccerssessocdssessenssoesiocdecoasensesessesssussbenseosstentassebadsedecestsececoaddasesdootaccesooasdeesoudaes 13 3 4 Meshing Configuration 15 3 5 Time LONE E R E EEE AR EEEE R 16 3 0 M 17 3 7 Licens aM 18 KA Hcr Mee 18 3 9 Administration ead tere Po yeso eg REN INC UL ERR EE SUR e eI TO E USE UR 19 3 10 Firmware 20 4 SERVICES aacra kn i ba aaa Yd RE LEA D ERE EA Du OF E nenna 21 AN DHCP 21 23 M 22 a Wa Pl ete 22 4 4 Walled a eosa apa aee eg rg e eua rp See PER Bae AE 25 A S PREPTOXY ETEO E E
2. 4 5 Preproxy When enabled in the firewall configuration file the Preproxy service is responsible for redirecting users to either the login page or the landing page It also allows users to visit sites on the walled garden without logging in The configuration may be edited to change the number of processes that are running at any given time Typically the default settings are fine but in a large network or if a lot of content is being displayed to users that are not signed on it is then a good idea to increase the number of Preproxy processes service Preproxy Walled Garden Figure 4 5 Preproxy Configuration 26 5 5 The Tools section provides the WiDirect administrator with the basic network troubleshooting tools of ping trace route and DNS query 5 1 Ping Ping allows an administrator to test network connectivity by sending a ping request to another machine on the network Enter in the target IP address of the remote machine to test and click the Ping button The results of the ping will be displayed This example is a successful ping of IP 192 168 20 248 PING 192 168 20 248 192 168 20 248 56 84 bytes of data 64 bytes from 192 168 20 248 seq 1 ttl 64 time 0 310 ms 64 bytes from 192 168 20 248 icmp_seq 2 ttl 64 time 0 264 ms 64 bytes from 192 168 20 248 icmp_seq 3 ttl 64 time 0 214 ms 192 166 20 248 ping statistics 3 packets transmitted 3 received 0 packet loss time 2000ms min avg
3. RO 26 BS Dvd ierat seid Feed vela rra eus dead y vkd rac AE EA CK id 27 DA DICES 27 5 2 CIC 27 5 3 DNS tr 28 6 COMMAND LINE 29 6 1 Secure Shell ero aon k ea n es Sae ieser 29 7 TECHNICAL SUPPORT 30 Preface About This Manual This manual is written for system administrators system integrators network administrators and others who use the WiDirect appliance and WiClients The WiDirect models span a broad spectrum of possible applications The product can be used to manage wire line and wireless networks The smaller models are appropriate for small office applications and local WISP applications Larger models can manage common carrier network environments Each WiDirect unit contains the same software and most of the features are available for use in each model The feature set within the WiDirect appliance and WiClient is broad and is expected to continue to grow over time These features provide significant capabilities that create a network infrastructure one that can be used in numerou
4. 321 622 ms 321 111 ms 15 12 215 8 163 client mchsi com 12 215 8 163 328 543 ms 16 10 3 1 50 10 3 1 50 338 253 ms 267 762 ms 27 5 3 DNS Query The DNS Query command allows an administrator to test DNS connectivity DNS is very important because the captive portal uses it to detect a user s initial Internet request DNS is also used in some services such as FTP For Domain resolution check go to the Tools menu and then DNS Query Type in a domain to query such as www google com and click the Lookup button The results will be displayed once the lookup completes DNS look up of www google com Server 192 168 200 1 Address 192 168 200 1453 Non authoritative answer www google com canonical name www l google com Name www l google com Address 64 233 161 99 Name www l google com Address 64 233 161 104 Name www l google com Address 64 233 161 103 Name www l google com Address 64 233 161 147 28 6 Command Line Interface 6 1 Secure Shell access An SSH client is required in order to access the command line interface of the WiDirect AllCity Wireless recommends using putty which is a free download at this website http www chiark greenend org uk sgtatham putty By opening putty or another SSH client connect to the IP address of the WiDirect machine By default this IP address is 10 4 1 1 on the 55101 interface However if the IP address of any of the WiDirect s interfaces has changed the new
5. 41 WiDirect user notice rdate No usable time server found Dec 31 19 06 11 WiDirect daemon info dnsmasq 687 reading tmp resolv conf auto Dec 31 19 06 11 WiDirect daemon info dnsmasq 687 using nameserver 192 168 1 1 53 Dec 31 19 06 11 WiDirect daemon info dnsmasq 687 using local addresses only for domain lan Dec 31 21 26 41 WiDirect user notice root Stopping ntpclient Dec 31 21 26 42 WiDirect user notice root Starting ntpclient Jan 26 13 19 47 WiDirect authpriv info dropbear 25630 Child connection from 192 168 22 250 48467 Jan 26 13 19 51 WiDirect authpriv notice dropbear 25630 password auth succeeded for root from 192 168 22 250 48467 Jan 26 13 27 17 WiDirect daemon info dnsmasq dhcp 687 DHCPREQUEST ath0 192 168 2 155 00 25 d3 8c 5d 2f Jan 26 13 27 17 WiDirect daemon info dnsmasq dhcp 687 DHCPNAK ath0 192 168 2 155 00 25 d3 8c 5d 2f wrong network Jan 26 13 27 20 WiDirect daemon info dnsmasq dhcp 687 DHCPDISCOVER ath0 00 25 d3 8c 5d 2f Ian 26 13 27 20 WiDirect daemon info 6871 DHCPOFFER athQ 10 4 1 225 00 25 d3 Rc d 2f Figure 3 6 Log Viewer 17 3 7 License Key If needed new license keys can be added to the WiClient To add new licenses select License Key under the System Configuration menu Browse to the directory where the license file is located on the local machine and then click Upload License Key Figure 3 7 License Key Depending on usage of the system and
6. Firewall filters traffic that is passing between the LAN and WAN sides of the WiClient Firewalls can be programmed to block traffic based on a wide variety of criteria Traditionally firewalls enforce policies to maintain network security by using a set of rules that determine whether or not traffic is allowed to pass between the LAN and the WAN on a per packet basis The following section describes all the possible items for the Firewall configuration The first section describes all the Non filtering firewall configuration items and the second section describes the traffic filtering configuration times Firewall filtering rules dictate which traffic is allowed inbound and outbound of the WiDirect 22 WiDirect Configuration AuthServer Address wifi annapoliswireless com Path portal SSL Available GetMacFromArp PreProxy WalledGarden PreProxy Port PostProxy PostProxy Port Redirect443 AllowOnAuthDown IgnoreMacFromClient HTTPDName WiDirect HT TPDMaxConn 100 Checkinterval 60 ClientTimeout _Save Config and Apply Figure 4 3 Firewall Configuration Page 4 3 1 1 Firewall Configuration Options Table 4 3 lists the firewall configuration items Keyword Description AuthServer Address The IP Address or URL of the WiDirect AuthServer Path Path to AuthServer Directory Do not change unless advised by AllCityWireless 23 551 Available Enable if you would like the users to be sent to the AuthS
7. IP address should be the one that used in the SSH connection If you are accessing from the Internet you ll want to use the public IP address of the WiDirect Once connected the system will ask for a login and password Administrators must use the root login to gain access If this is a new system the password will be widirect Once connected Administrators are free to use any of the standard Unix commands to navigate the system To exit the command line interface use the logout command or CONTROL D NOTE If editing files consult the VI quick reference guide located in the WiDirect user manual located on the AllCity Wireless Support site 29 7 Technical Support Support Contact Details Dedicated e mail support support allcitywireless com Self support www allcity wireless com support Corporate Address 326 First Street Suite 23 Annapolis MD 21403 30
8. USA The State of Maryland shall be the exclusive venue for the resolution of any such disputes AllCity Wireless total liability for all claims will not exceed the price paid for the hardware product Unless you request and receive written permission from AllCity Wireless you may not copy any part of this document Information in this document is subject to change without notice Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders Copyright 2011 AllCity Wireless LLC All rights reserved Printed in the United States of America 1 Revision History Date Editor Description 1 0 02 23 2011 JPB Initial Draft Table of Contents PREFACE ABOUT THIS MANL AL snecoans odnipee usse opua p SE eu Ee ions E 5 WICLIENT ADMINISTRATION eee eeee nnne nennen 6 1 LOGGING IN 6 2 SYSTEM 6 PA Mni EE RN 7 2 2 SYVStEM CHECK sscscsecessossacessdsvesseusdoassuad cvessusstsoievncsvassesedoasenotesoaesscssoussoussdnsseessasasobaveuss sibs usens soupseveteassnnssvassuessend 7 IARI ESIE A EA EIEE E EN A A T ALTARES AAT 8 2 4 I EUERE Graph RER E T A E T A EE 9 3 SYSTEM CONFIGURATION
9. the license that was originally purchased a new license may need to be purchased to support more features Consult the AllCityWireless com website to determine the type of license required 3 8 Restart The Restart page listed under the System Configuration menu allows the Administrator to reboot the WiClient unit 18 3 9 Administration The Administration page is used to change the admin password for administration from the web interface You may also change the WiDirect Operational mode by selecting a new mode from the drop down interface Modes available are determined by the license on the WiDirect Administration New Password D Factory Default Figure 3 9 Administration Configuration 19 3 10 Firmware Upgrade The WiClient Firmware allows for firmware upgrades through the Administration web interface You may retrieve firmware updates from http www allcitywireless com After uploading the firmware to the device your device may become unresponsive for 2 5 minutes while applying the updates You may also choose to clear the device s configuration by deselecting Configuration prior to submitting the firmware Firmware Upgrade Do not remove power from the device while the system is upgrading The system will restart after completion of the upgrade TL Browse Keep Configuration Figure 3 10 Firmware Upgrade 20 4 Services Menu 4 1 DHCP The WiClient p
10. 00 57 WiDirect user warn kernel jffs2 build filesystem unlocking the mtd device done Dec 31 19 01 55 WiDirect user warn kernel jffs2 build filesystem erasing all blocks after the end marker done Dec 31 19 01 55 WiDirect user info sysinit copying files done Dec 31 19 01 55 WiDirect user info kernel mini fo using base directory Dec 31 19 01 55 WiDirect user info kernel mini fo using storage directory overlay Dec 31 19 01 56 WiDirect authpriv info dropbear 1189 Running in background Dec 31 19 05 36 WiDirect user info kernel eth0 Configuring MAC for full duplex Dec 31 19 05 38 WiDirect user info sysinit Sending select for 192 168 21 249 Dec 31 19 05 38 WiDirect user info sysinit Lease of 192 168 21 249 obtained lease time 345600 Dec 31 19 05 39 WiDirect user info sysinit udhcpc ifconfig eth 192 168 21 249 netmask 255 255 224 0 broadcast Dec 31 19 05 39 WiDirect user info sysinit udhcpc setting default routers 192 168 1 1 Dec 31 19 05 39 WiDirect user info sysinit udhcpc setting dns servers 192 168 1 1 Dec 31 19 05 40 WiDirect daemon info olsrd 720 Writing 0 was 1 to proc sys net ipv4 conf eth redirects Dec 31 19 05 40 WiDirect daemon info olsrd 720 Writing 0 was 0 to proc sys net ipv4 conf eth rp filter Dec 31 19 05 40 WiDirect daemon info olsrd 720 Adding interface Dec 31 19 05 40 WiDirect daemon info olsrd 720 New main address 192 168 21 249 Dec 31 19 05
11. 95 WiDirect ECB3500 00 1F 90 FF 07 CO Master 2412 1 2 70 _ 3 wep 90 84 0D D5 56 59 Master 2412 1 070 o5 moe O0 1F 90 CA FI 9C Master 2412 1 95 95 00 26 62 60 9 89 Master 2437 6 24 0 71 95 07294 00 1 90 1 6 7 Master 2437 6 170 594 95 _ YURGB 00 1F 90 CE F8 48 Master 2437 3 0 92 o5 wep gt 00 02 6F 87 C4 1D Master 2 447 8 34 70 61 95 itdontmatter 06 02 6F 87 C4 1D Master 2447 8 3670 59 95 freepublicwif 0A 02 6F 87 C4 1D Master 2447 8 36 70 59 95 none _ paidpublicwif 0E 02 6F 87 C4 1D Master 2447 8 36 70 95 mone davidwitr 00 15 99 34 F1 CE Ad Hoc 2457 10 2 70 95 none _ airportthru Figure 2 3 Site Survey 2 4 Status Graph The WiClient Firmware includes a live status graph for reporting CPU Utilization as well as Network Interface Utilization This utility will be beneficial for troubleshooting network performance Figure 2 4 1 shows the CPU utilization graph and Figure 2 4 2 illustrates interface athO graph Live Graph Status Graph Interface CPU 13 8 75 Ns Figure 2 4 1 CPU Graph Status Graph continued Live Graph Status Graph Interface In 1 Kbps Switch to bytes s Out 0 Kbps Autoscale follow M LL Ld AA E Figure 2 4 2 Interface athO Graph 10 3 System Configuration 3 1 Network Configuration Accurate networ
12. SNMP Server WatchDog Interface Settings atho Link encap Ethernet HWaddr 00 02 6 89 AB D3 inet addr 10 4 1 1 Bcast 10 4 1 255 5 255 255 255 0 UP BROADCAST RUNNING MULTICAST MTU 1500 Metric 1 RX packets 73939 errors O dropped 777 overruns O frame O TX packets 72132 errors O dropped O overruns O carrier O collisions O txqueuelen O RX bytes 51520383 49 1 MiB TX bytes 78251918 74 6 MiB etho Link encap Ethernet HWaddr 00 02 6F 89 AB D2 inet addr 192 168 21 249 Bcast 192 168 31 255 5 255 255 224 0 UP BROADCAST RUNNING MULTICAST MTU 1500 1 packets 88318 errors O dropped O overruns O frame O TX packets 87598 errors O dropped O overruns O carrier O collisions O txqueuelen 1000 RX bytes 80586348 76 8 MiB TX bytes 54432795 51 9 MiB Interrupt 4 Base address 0x1000 Figure 2 2 System Check 2 3 Site Survey It is recommended to do a wireless survey prior to installing access points Included in the WiClient firmware is a site survey utility to list all of the local networks and their corresponding channels Be sure to run the site survey utility and refresh the screen 3 times to see all potential conflicting signals Site Survey Last Scan at Wed Jan 26 13 55 28 EST 2011 8650 Mode 3 Mode Frequency Channel Quality Signal Level Noise Level Encryption SSID 00 1F 9 00 02 6F 8D 6A B3 Master 2412 1 770 88 none WiDirect 00 02 6F 74 76 D7 Master 2 412 1 64 70 31
13. WICLIEIN T Firmware USER MANUAL SUPPLEMENT Software Release 1 4 The information in this User Manual has been carefully reviewed and is believed to be accurate The vendor assumes no responsibility for any inaccuracies that may be contained in this document makes no commitment to update or to keep current the information in this manual or to notify any person or organization of the updates For the most up to date version of this manual please visit the AllCity Wireless support website at http www allcity wireless com support AllCity Wireless reserves the right to make changes to the product described in this manual at any time and without notice This product including software if any and documentation may not in whole or in part be copied photocopied reproduced translated or reduced to any medium without prior written consent IN NO EVENT WILL ALLCITY WIRELESS LLC BE LIABLE FOR DIRECT INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION EVEN IF ADVISED OF THE POSSIBILITY OR SUCH DAMAGES IN PARTICULAR THE VENDOR SHALL NOT HAVE LIABILITY FOR ANY HARDWARE SOFTWARE OR DATA STORED OR USED WITH THE PRODUCT INCLUDING THE COSTS OF REPAIRING REPLACING INTEGRATING INSTALLING OR RECOVERING SUCH HARDWARE SOFTWARE OR DATA Any disputes arising between manufacturer and customer shall be governed by the laws of Anne Arundel County in the State of Maryland
14. erver Login with SSL GetMacFromArp Retrieve the User s Mac Address by means of querying the ARP Table PreProxy WalledGarden Preproxy must be enabled to use the walled garden or landing page feature Set preproxy to Off to disable these features PreProxy Port The Port that the PreProxy will listen for Requests on PostProxy PostProxy must be enabled to use the Ad Insertion feature of the WiDirect PostProxy Port The Port that the PostProxy will listen for Requests on AllowOnAuthDown Allow users to maintain Internet Connectivity in the event the AuthServer is unreachable Table 4 3 Firewall Configuration Items 24 4 4 Walled Garden The WiDirect s Walled Garden allows administrators to host local content e g community website that can be integrated into the captive portal landing page For example administrators might want their users to go to google com without network authentication In order to allow this only google com needs to be added to the Walled Garden list The Walled Garden list can be set to retrieve and synchronize the local Walled Garden List with the Master list on the Authentication Server Walled Garden www annapoliswireless com www aacspca org www voLunteerannearundel org www allcity wireless com www foodandwinenh com www redcross org maps google com maps gstatic com www annapolis tours com Save Config and Apply Figure 4 4 Walled Garden 25
15. he appropriate log file by clicking on the link and a separate screen opens to view the log This page will update as new entries are being added to the log file Log Viewer w View Log SYSLOG Mozilla FireFox File Edit View History Bookmarks Tools Help With the log viewer you can watch log Select a log to view http 192 168 21 249 portal admin logviewer viewlog php log SYSLOG amp history 50 Viewing Log SYSLOG StartLog Pause Log var log messages 50 Dec 31 19 00 49 WiDirect user info sysinit Generating Configuration Information Dec 31 19 00 53 WiDirect user info sysinit Starting WiDirect Client Dec 31 19 00 54 WiDirect daemon info olsrd 720 olsr org 0 6 1 git hash 1df3d5dlb9a4fl b b95cacBal 7627430 successfully started Dec 31 19 00 54 WiDirect user info sysinit 3 Wed Dec 31 19 00 54 1969 819 gateway c 522 UNABLE TO FIND SERIAL FILE EXITING Dec 31 19 00 55 WiDirect user info sysinit Attempting to retrieve our License Key from AllCityWireless com Dec 31 19 00 55 WiDirect user info sysinit Attempting to Retrieve our WalledGarden From our Auth Server Dec 31 19 00 55 WiDirect user info sysinit Generating Configuration Information Dec 31 19 00 55 WiDirect user info sysinit Starting WiDirect PreProxy Dec 31 19 00 56 WiDirect user info sysinit UNABLE TO FIND SERIAL FILE EXITING Dec 31 19 00 57 WiDirect user warn kernel jffs2 scan eraseblock End of filesystem marker found at 0 0 Dec 31 19
16. he default use the new Gateway address instead of 10 4 1 1 2 System Status Menu The system status menu is the first menu that is located in the left hand navigation bar of the WiDirect web GUI 2 1 The Home button which is located in the top left hand corner of the administrator page returns the user to the home screen This is the same page that is displayed upon first logging into the WiClient The home page gives a quick overview of the device role if a license is present and if the WiClient is associated with a WiDirect Authorization Server WiDirect Authentication Server association and Licensing is discussed in greater detail later in this manual supplement 2 2 System Check The System Check page under the System Status menu displays a snapshot of the current health of the WiClient system as show in Figure 2 2 This page analyzes important system functions such as DHCP Firewall NTPD and PreProxy services by establishing if they are running Other information that can be found on this page is Interface Settings Routing table NTP status and Network statistics When contacting ACW technical support the data on this page will be used to troubleshoot the health of the WiClient Changes to all the configurable services can be made by clicking the control link in the row across from the specific service you wish to make changes to Testing Services DHCP DNS Firewall PreProxy Walled Garden NTP Client
17. k configuration IP addressing is critical to the proper operation of the WiClient All network configuration and routing configuration is controlled via the Network Configuration page under the System Configuration menu Figure 3 1 shows the Network Configuration window This page allows configuration of the WiClient interfaces the default route and the DNS servers The first section allows the administrator to set which interface is to be used as the WAN interface By default the WAN interface is ETHO If DHCP is enabled the Default Route and DNS server fields will be disabled because that information will be retrieved via DHCP By default the ETHO interface is configured for DHCP while the SSIDI interface uses the standard 10 4 1 1 24 subnet addressing scheme Network Configuration 192 168 18 255 255 255 224 0 192 168 1 1 192 168 1 1 192 168 1 1 Cancel a Doo CU e Hefe Gateway Subnet Protection O OOOO Figure 3 1 Network Configuration 11 32 Gateway Subnet Protection To have WiClient apply policies on a specific SSID check the box Intercept and assign a valid profile to the network interface This is to allow for other SSIDs to be broadcast without WiDirect intervention on the user experience You may also block all other LAN Subnets by selecting Gateway Subnet Protection This is enabled or disabled on a Per SSID Basis Gateway Subnet Protection isolates all othe
18. max mdev 0 214 0 262 0 310 0 043 ms 5 2 Trace route Like the Ping command the Trace route command tests network connectivity by attempting to find the network path between the WiDirect and another network device Type in the target address and click the Trace route button The results of the Trace route will be displayed after the WiDirect executes the command Example output traceroute to 10 3 1 50 10 3 1 50 30 hops max 40 byte packets 1 balance 192 168 200 1 1 875 ms 2 286 ms 2 747 ms 2 73 135 120 1 73 135 120 1 81 174 ms 93 181 ms 93 600 ms 3 ge 1 20 ur01 annapolis md bad comcast net 68 87 136 205 94 065 ms 94 535 ms 94 514 ms 4 te 9 3 ur02 gambrills md bad comcast net 68 87 128 150 94 983 ms 94 957 ms 96 891 ms 5 te 9 1 ur01 gambrills md bad comcast net 68 87 129 17 94 858 ms 97 319 ms 97 295 ms 6 te 7 1 ar01 capitolhghts md bad comcast net 68 87 129 22 97 265 ms 79 813 ms 80 194 ms 7 12 86 111 5 12 86 111 5 81 152 ms 117 899 ms 141 375 ms 8 tbr2 wswdc ip att net 12 122 113 78 162 803 ms 163 262 ms 163 726 ms 9 crl wswdc ip att net 12 122 16 89 164 194 ms 164 173 ms 164 619 ms 10 cr2 phlpa ip att net 12 122 4 53 165 089 ms 165 062 ms 165 504 ms 11 tbr2 phlpa ip att net 12 122 20 86 167 469 ms 167 444 ms 167 894 ms 12 tbr2 cgcil ip att net 12 122 10 93 166 859 ms 171 816 ms 172 279 ms 13 12 122 99 93 12 122 99 93 113 359 ms 105 891 ms 183 838 ms 14 12 215 4 17 client mchsi com 12 215 4 17 321 209 ms
19. on Key The encryption key is available when Encryption mode is not None SSID Rate Select the DataRate that you would like the Radio to use Recommended Auto Once the configuration is changed you would select Save Config and Apply The wireless will reinitialize with the new configuration 13 Wireless Configuration Figure 3 3 Wireless Configuration 14 3 4 Meshing Configuration The WiClient Firmware includes wireless meshing functionality in the event you wish to install another device which does not currently have Ethernet connectivity For the device with Ethernet connectivity you would assign the Mesh Mode as a Gateway and Repeater on the standalone unit If the device is equipped with a second radio you may assign the Meshing functionality to the Second Radio by Mesh Radio to separate the wireless operations improving throughput Mesh Configuration Configuration Edit m Save Config and Apply Cancel Figure 3 4 Meshing Configuration 15 3 5 Time Zone Select Time Zone under the System Configuration menu From the drop down menus set the time zone Don t forget to click the Update button next to the appropriate commands to implement your selections Local TimeZone submit Figure 3 5 Date and Time 16 3 6 Log Viewer With the Log Viewer page located under the System Configuration menu log files can be viewed in real time Choose t
20. r internal routable subnets from traffic coming from a specific SSID and forces that traffic to the internet gateway only Use this feature to protect systems sharing a common internet connection such as POS or other computers in the enterprise Network Configuration 192 168 18 255 255 255 224 0 921683 192 168 1 1 192 168 1 1 Cancel a oo CU Y Gateway Subnet Protection Y 0 0000 Figure 3 2 Subnet Protection 12 3 3 Wireless Configuration The WiDirect allows for multiple SSID s and various encryption and connectivity settings The following section describes all the possible items for the Wireless configuration Keyword Description Country The country must be set to properly regulate the channel and transmit power regulatory limitations Antenna If the device is equipped with multiple antennas per radio you may select to use diversity or assign the radio to use a single antenna Channel Select the Channel that you wish the WiDirect to operate on You may wish to do a site survey prior to selecting a new channel Transmit Power Select the Transmit Power that the radio should operate with SSID Enabled Enable the use of the Selected SSID SSID Encryption Mode Select which Encryption method you would like to use NONE WEP WPA PSK WPA2 PSK WPA PSK WPA2 PSK Mixed Wep Key Length 64bit 5 Characters 128bit 13 Characters SSID Encrypti
21. rovides DHCP services to all available SSID interfaces Keyword Description SSID Disabled Check this to prevent the DHCP Server from listening on the SSID Interface SSID Start Address The first assignable IP In the Address Pool Range SSID End Address The last assignable IP In the Address Pool Range SSID Lease Time The length of the DHCP Lease After which the associated client will send a new DHCP Request Once the configuration has changed use the Save Config and Apply to save the changes This button is shown in Figure 4 1 Service DHCPD Interface Disabled StartAddress End Address Lease Time ssi 041 gt Hos Figure 4 1 Service DHCP 21 4 2 NTP Client The WiClient internal clock must remain accurate for a number of the critical systems to function In order to make this work properly an NTP server is polled to synchronize the internal clock with a known NTP clock NTP also provides time services to local devices To edit the NTP configuration go to the NTP Client page under the Services menu This is the standard NTP configuration and it will allow you to change NTPD servers as needed If more information is required for configuring NTP please see the NTP web site http www ntp org Service NTPClient i cm NN Update interval 600 update Cancel Figure 4 2 NTPD Configuration 4 3 Firewall The WiClient s
22. s creative ways depending on the environment If you are installing a WiDirect or WiClient for the first time you should read this entire supplement as well as the entire WiDirect user manual to become familiar with the settings and tools However the steps to actually install and configure a new WiDirect begin with Section 3 Installation In the user manual located at www allcity wireless com support WiClient Administration Interface 1 Logging In In order to gain initial access to the WiClient s web based GUI plug the flashed WiClient access point into power After the WiClient is fully booted up 1 minute establish a wireless connection over WIFI to the SSID WiDirect for initial configuration Once connected the WiClient provides the other connecting device with an IP address in the 10 4 1 0 24 subnet via DHCP Be sure that the connecting computer is configured for DHCP to receive the IP address Once the IP address has been established open a web browser such as Firefox and open the following URL http 10 4 1 1 portal admin This URL opens the WiDirect Admin login page as shown in Figure 1 1 To login use the preconfigured username of admin and the password widirect Authentication Required x e amp A username and password are being requested by http 192 168 18 255 The site says wiDirect Password cane Figure 1 1 WiDirect Login Note If the default gateway of SSID1 has changed from t

Download Pdf Manuals

image

Related Search

Related Contents

Descargar Manual de Instalación y programación  mode d`emploi des financements a personnes  APH 4 - Province de Hainaut  Hitachi VT-FX6407AS VCR User Manual  Préprogramme  CENTRES D`USINAGE À BROCHE VERTICALE Haas  取扱説明書 TOSHIBA Viewer 編  [FR] - FEE DU LOGIS (Pliz) Surfaces modernes Nettoyant  WC3119_Service_Manual8.06 MB  Radio Shack 43-3812 Cordless Telephone User Manual  

Copyright © All rights reserved.
Failed to retrieve file