1. To enter the password use the A or V buttons to select 2 as the first digit Press the button 10 Use the A or V buttons to select 5 as the second digit 11 Press the button twice 12 Use the arrow buttons in the same fashion to enter the weight of the object being used for calibration 13 Press the button 14 Place the weight on the scale 15 Press the Enter button 16 The screen will display Yes or No If yes is selected the unit will begin to calibrate the scale If no is selected the display will return to the main menu 17 Check calibration with the weight from above using Scale Mode WHNAUAWN Scale Mode Scale mode will cause the unit to operate like a laboratory scale The unit will not show a negative weight If needed use the Tare button to re set the zero of the scale 1 Press the Menu button 2 Use the A or V buttons to select Special Functions 3 Press the Enter button 4 Use the A or V buttons to select Scale Mode 5 Press the Enter button The scale can now be used to accurately weigh an object If checking calibration 6 Place the same weight used during calibration on the scale 7 Check the weight displayed against the known weight of the object 8 If the weight displayed does not match the known weight then repeat the calibration process Otherwise press Menu or Abort to return to the main menu SILADENT Dr B hme amp Sch ps GmbH Tel 49 0 53 21 37 79 0 info sbs dental
2. HO SILADENT Dr B hme amp Sch ps GmbH Tel 49 0 53 21 37 79 0 info sbs dental de Im Klei 26 Fax 49 0 53 21 38 96 32 www sbs dental de D 38644 Goslar Front View Arm to access hose Distilled Expansion water liquid SILADENT Dr B hme amp Sch ps GmbH Tel 49 0 53 21 37 79 0 info sbs dental de Im Klei 26 Fax 49 0 53 21 38 96 32 www sbs dental de D 38644 Goslar Back View Scale socket ON OFF g Switch Power cord socket Expansion Distilled liquid water SILADENT Dr B hme amp Sch ps GmbH Tel 49 0 53 21 37 79 0 info sbs dental de Im Klei 26 Fax 49 0 53 21 38 96 32 www sbs dental de D 38644 Goslar J SILADENT After unpacking the dispenser and all of its accessories please follow these installation instructions Place the dispenser on a level surface Position scale between the base legs of the dispenser shown on page 2 Align scale so that the scale cover is directly beneath the dispensing hose Do not allow scale chassis to contact column or feet of dispenser this contact may result in inaccuracy Slide scale cord between stand and water bottle and attach the scale cord to the scale socket on the back of the unit shown on page 3 Fill the water bottle with distilled water secure cap and place the bottle on the left side of the unit Use water only chemicals added here may damage the internal pumps You may use the included extension hose and inline hose
3. is free of debris and crystallized particles OR Out of Special Liq Tightly secure the bottle cap error Gently pinch the end of the special liquid hose to free crystallized particles Replace the special liquid cap assembly Unit hums loudly Ensure the bottle cap is free of debris and crystallized particles Tightly secure the bottle cap Replace the special liquid cap assembly Special liquid will not stop Check that special liquid hose is uniformly seated in the pinch i valve see page 10 Replace the special liquid cap assembly Castings are too large Reduce special liquid concentration by 0 5 ml or 1 until size is correct Castings are too small Increase special liquid concentration by 0 5 mL or 1 until size is correct SILADENT Dr B hme amp Sch ps GmbH Tel 49 0 53 21 37 79 0 info sbs dental de Im Klei 26 Fax 49 0 53 21 38 96 32 www sbs dental de D 38644 Goslar Technical data Dimensions Weight User Programs Display Characters Operational Altitude Operation Temperature Maximum Relative Humidity Pollution Tolerance Recommended Environment Warranty SILADENT Dr B hme amp Sch ps GmbH Im Klei 26 D 38644 Goslar J SILADENT 30 cm W x 59 cm H x 33 5 cm D 200 240 VAC 50 60 Hz 15 4 lines x 20 characters Sea level 2 000 meters 6 560 feet 130 C 419 C 550 F 105 F 80 for temperatures to 35 C 950 F decreasing linearly to 50 relative humidity
4. J SILADENT LD 1 Water and expansion liquid dispenser for dental gypsum and investments 15 memory spaces for programs of different products eliminates handling mistakes with the liquid and water ratio exact control of the expansion constant and reproducible casting results SILADENT Dr B hme amp Sch ps GmbH Tel 49 0 53 21 37 79 0 info sbs dental de Im Klei 26 Fax 49 0 53 21 38 96 32 www sbs dental de D 38644 Goslar J SILADENT Application range The LD1 is a multifunctional dispenser unit Automatically it adds the exact needed water or liquid ratio to all kinds of amounts of investments or gypsums you use Operating errors will be avoided because of its 15 freely configurable programs This causes a short handling time exact expansion data and hardness which reduce reworking and achieve qualitative high end results BOX CONTENTS 1 Power Cord 1 User s Manual 4 1 Liter Bottles 1 Scale 1 Scale Cover 1 4 ft Clear Extension Hose 1 Inline Hose Connector 1 Funnel 1 Quick Start Guide 1 Water Bottle Cap and Tubing 4 Special Liquid Bottle Caps and Tubing TABLE OF CONTENTS Front Back View Set Up Programming the LD1 Running a Program I D auuw NO Special Functions Calibration Scale Mode Set Language Erase a Program Purge Liquid Prime Water Hose Maintenance Replacing the Special Liquid Hose Troubleshooting Technical data FPrWOWOMOMOOAOONN
5. arm Allow the hose to extend approx 1 inch below the opening Fig 3 Place your thumb on the hose nearest the white pinch valve and hold with direct pressure Fig 4 Stretch the hose and slide into the pinch valve The hose should Slide in easily if not stretch the hose further Thread the other end of the hose through the opening in the outer rear of the swing arm assuring there are no kinks in the hose Place the hose onto the center nodule on the cap SILADENT Dr B hme amp Sch ps GmbH Tel 49 0 53 21 37 79 0 info sbs dental de Im Klei 26 Fax 49 0 53 21 38 96 32 www sbs dental de D 38644 Goslar J SILADENT TROUBLESHOOTING Screen lights up but no Check the scale cable connection words are displayed Will not dispense water Ensure there is sufficient water in the container Or Out of Water error Ensure the clear hose is fully seated on the center of the bottle cap Remove excess air from the hose by running the Prime Water Hose cycle Be sure dispensing is completed before removing bowl from scale Dispensed too much Make sure the bowl finished the Tara before adding the powder water Water and or special Since the unit weighs the amount of water special liquid in the liquid splashed from bowl bowl this will not affect accuracy Check alignment of scale Excessive clicking or will Ensure there is sufficient liquid in the bottle not dispense special liquid Ensure the bottle cap
6. at 35 C 104 F Level 2 in accordance with IEC 664 Vertical position indoors within operational parameters 2 years parts and labor Tel 49 0 53 21 37 79 0 Fax 49 0 53 21 38 96 32 info sbs dental de www sbs dental de
7. connector to allow the use of a larger container such as a one gallon jug Insert the connector end into the clear tubing from the unit and place the hose directly into a container The special liquid bottle can be filled with investment liquid or die stone additive Fill the special liquid bottle with liquid secure cap by holding the cap and turning the bottle until tight Place the bottle on the right side of the unit The special liquid bottle is pressurized during operation If the cap is not tightly secured air will escape and the liquid will not flow properly Insert the power cord into the socket on the back of the unit see page 3 and plug the power cord into an outlet Turn the unit on using the switch located on the back of the unit CAUTION Do not interchange the bottle caps The gray cap is for the special liquid side only and the blue cap is for the water side only PROGRAMMING THE LD Programs can be added or edited in two ways The first method is g ml a program based on grams of powder and mL of water and or liquid i e 100 grams of powder 18 mL special liquid and 5 mL water The second method is by grams of powder and percentage of special liquid i e 100 grams of powder 80 special liquid and 20 water Your current lab method or manufacturer s documentation may dictate which programming method to use Note The unit will dispense water and or special liquid accurately for up to 1200 grams of powder eve
8. de Im Klei 26 Fax 49 0 53 21 38 96 32 www sbs dental de D 38644 Goslar SILADENT Set Language Use the A or V buttons to move the cursor to the desired language The unit can display in English French German Italian and Spanish Press the enter Key The unit will prompt for confirmation Press Enter to confirm or press the Abort to abort and return to main menu Bal ea Erase a Program Press the Menu button Use the A or V buttons to select Special Functions Press the Enter button Use the A or V buttons to select Erase a Program Press the Enter button Use the A or V buttons to select the program number 1 15 to erase Press the Enter button Press the Enter button again to erase the program or press the Abort button to return to the main menu without erasing the program SS OV OT Si Purge Liquid This function allows you to flush the special liquid hose This may be useful if changing between bottles that contain differing liquids while using the same cap and hose assembly Press the Menu button Use the A or V buttons to select Special Functions Press the Enter button Use the A or V button to select Purge Liquid With a container on the scale press the Start button After the first few drops fall from the hose press Abort to end a W Prime Water Hose Use this function if you encounter an Out of Water error and there is water visible in the bottle or other container 1 Pres
9. e the program Press the gt button to advance to the next position Press the lt button to move back to the previous space 7 Once the name is complete press the Enter button to move to the next screen 8 Use the A or V buttons to enter the total liquid required in mL and powder in grams Note Total liquid required is total volume of both water and special liquid in ml 9 Use the A or V buttons to indicate the special liquid concentration This is the percent of the special liquid only to be dispensed 0 dispenses only water 100 dispenses only special liquid You will not be required to enter the percent of water i e if you enter 80 special liquid concentration the unit assumes 20 water 10 Press the Enter button 11 The screen should display Program Saved RUNNING A PROGRAM Before running a program check that the special liquid hose end is not clogged and will allow special liquid to flow see the Maintenance section on page 9 for more details From the Main Menu Use the A or V buttons and select Run Program Press the Enter button Use the A or V buttons to select the number of the program you wish to run 1 15 Place an empty bowl on the scale Press the Tare button Remove the bowl from the scale and place the desired powder into the bowl Return the bowl to the scale Press the Start button Soe a ee The dispenser will begin to dispense the liquids separately beginning with water and finishing w
10. ith special liquid The display will indicate when the program is finished and the unit will beep until the bowl is removed from the scale Note If the dispenser tries to dispense from either side for 30 seconds 15 seconds for the water only unit and the weight on the scale does not increase it will give an error Usually SILADENT Dr B hme amp Sch ps GmbH Tel 49 0 53 21 37 79 0 info sbs dental de Im Klei 26 Fax 49 0 53 21 38 96 32 www sbs dental de D 38644 Goslar J SILADENT this means it is out of water special liquid or the special liquid hose may be clogged see Maintenance section on page 9 for more details Due to set time we suggest that the failed batch be thrown away Refill the empty bottle and then re run the program with fresh investment or stone SPECIAL FUNCTIONS MENU Calibration The scale arrives calibrated from the factory The calibration information is stored in the scale so changing scales will not necessitate a recalibration The scale should rarely if ever need to be calibrated 1 Obtain a 500 g to 1200 g known weight If needed weigh an object on a separate scale in order to calibrate the dispenser Be sure the rubber scale cover is clean Press the Menu button Use the A or V arrow buttons to select Special Functions Press the Enter button Use the A or V arrow buttons to select Calibration Press the Enter button The display will read Enter Password The password is 250
11. n if the program entered is based only on 100 grams of powder g mL program add edit mode 1 Press the Menu button 2 Use the arrow buttons to select Edit Program by mL g 3 Press the Enter button 4 Use the A or V buttons to select a program number 1 15 5 Press the Enter button 6 Use the A or V buttons to select the numbers or letters to name the program Press the gt button to advance to the next position Press the lt button to move back to the previous space 7 Once the name is complete press the Enter button to move to the next screen 8 Use the A or V buttons to enter the amount of powder in grams SILADENT Dr B hme amp Sch ps GmbH Tel 49 0 53 21 37 79 0 info sbs dental de Im Klei 26 Fax 49 0 53 21 38 96 32 www sbs dental de D 38644 Goslar J SILADENT 9 Use the A or V buttons to indicate the amount mL of Special Liquid to dispense per the given powder weight above 10 Press the Enter button 11 Use the A or V buttons to indicate the amount mL of Water to dispense to complete the total ratio in ml 12 Press the Enter button when complete 13 The screen should display Program Saved program add edit mode 1 Press the Menu button 2 Use the A or V arrow buttons to select Edit Program by 3 Press the Enter button 4 Use the A or V buttons to select a program number 1 15 5 Press the Enter button 6 Use the A or V buttons to select the numbers or letters to nam
12. s the Menu button 2 Use the A or V buttons to select Special Functions 3 Press the Enter button 4 Use the A or V button to select Prime Water Hose 5 With a container on the scale press the Start button 6 After air is removed from hose press Abort to end MAINTENANCE Note Some special liquids crystallize when exposed to air and may impede dispensing of special liquid Daily maintenance is required SILADENT Dr B hme amp Sch ps GmbH Tel 49 0 53 21 37 79 0 info sbs dental de Im Klei 26 Fax 49 0 53 21 38 96 32 www sbs dental de D 38644 Goslar SILADENT With a damp paper towel gently pinch the tip of the Special Liquid hose to free crystallized particles This should be done each morning before use and any time the dispenser has not been used for several hours As needed 1 Wipe down the unit with a damp cloth 2 Remove the scale cover and clean 3 If the special liquid hose develops a clog that is not near the open end replace it Replacing the Special Liquid Hose Fig 1 To replace the special liquid hose losen the LD1 bottle cap to depressurize the bottle and swing open the arm as shown Remove the white hose from the center nodule of the cap place your thumb on the hose nearest the white pinch valve Fig 3 stretch the hose Fig 4 and remove the hose from the pinch valve Fig 2 Insert the end of a new white special liquid hose into the round opening on the inside left of the