HEAT PUMP WATER HEATER - sinclair air conditioners
Contents
1. E The earth pole of terminal must be earthed and the rated Table 2 1 current should be more than 10A Make sure that power supply terminal and power supply plug are dry enough and Accessory Name a j goa CAN Owner s amp Installation Installation and use instruction ethod Turn on power supply run the unit for half a hour then eee g This manual turn it off and check whether the power supply plug is hot or nor lf it s hot more than 50 C please change it with a new KE l and eligible one or it may result in an electric shock or fire elat FU O EE I EENET E Do not use the air source water heater for other purposes One Way Valve Sita lar norm m Before cleaning be sure to stop the operation and turn the breaker off or pull out the power cord Adaptor 1 B Drain condensate water Otherwise an electric shock and injury may be caused m The hot water probable need to mix with cold water too hot water over 50 C in the heating unit may could injury 3 INSTALLATION LOCATION m In order to avoid injury do not remove the fan guard on the outdoor unit E Enough space is installation and maintenance shall be m Do not operate the air source water heater with a wet hand preserved An electric shock may be caused m The air inlet and outlet should be free from obstacles and strong m The installation height of power supply should be over 1 8m if wind any water may spatter And safe from water m The bearing surface should be flat
2. Operation E heating Mode it lights up HYBRID MODE indicator When user sets the Hybrid Mode it lights up ECONOMY MODE indicator When user set the Economy Mode it lights up 1 Control Panel Explanation TIME ON 0 TIME OFF K Aap 5 g T 3 Operation Fig 8 3 ON OFF key UP key 2 Display Explanation used to turn the used to add time or temp TEMP SET 6 o H cH O T D TIME ON key TIME OFF key used to set the ON used to set the Oo Fig 8 4 4 Operation Instruction Table 8 1 m Preparation before running the unit HIGH TEMP indicator When the setting temp exceeds 50 C it lights up to remind you that the outlet temp is too high for direct spray When you run the unit for the first time all the indicators on the UI will light for 3 second and the buzzer will didi ring twice at the same time and then display the fiducial web page After no FILL WATER indicator When the power supply is turned on it lights up to remind you to re affuse water ALARM indicator It will flashing at the malfunction or protection time TEMP SET indicator Show the setting temperature and blank when screen protection Codes are show at the malfunction or protection time LOCK indicator When the UI is locked it always lights Water temp indicator When the actual water temp exceeds 60 C it lights up Water temp indicator When the actual water temp exceeds 50
3. t open to heat when the control signal is open circuit signal the heat pump system will be relieved its locked state and the unit will judge to open or shut down according to the unit s own condition m The CN18 Feedback port is used to send the feed backing of open stop situation to the solar thermal this port feeds back the high and low level signals When both sides of the terminal is low level OV for outlet means that the heat pump unit is under open state when both sides of the terminal is high level 5V for outlet means that the heat pump unit is under shut down state Installation amp Owner s Manual 4 m Which need to be declared is that the heat pump unit only receives and provides the above two signals the control software needs to be wrote according to the entire water heating system control while designing the project installation Be caution as the water tank can automatic recover temperature protection switch TCO when operating temperature is 78 C and the operating temperature for the manual recover temperature protection switch is 85 C when the water temperature of the solar thermal which enter the water tank coil is over heated higher than the operating temperature of the TCO it will lead to TCO operates and every part of the machine loads include the power of the main control board the display screen will be cut off so please be sure the water temperature of the solar thermal which ente
4. Ei Heat up Time 08 00 00 07 00 00 06 00 00 S 05 00 00 9 15 45 m 15 50 04 00 00 4 15 55 15 60 03 00 00 02 00 00 7 2 2 7 10 15 20 25 30 35 40 43 Ambient Temp C Installation amp Owners Manual 15 10 MAINTENANCE 10 1 Maintenance m Check the connection between power supply plug and socket and ground wiring regularly E Insome cold area below 0 C if the system will be stopped for a long time all the water should be released in case of freezing of inner tank and damage of e heater m It is recommended to clean the inner tank and e heater regularly to keep an efficient performance mM Check the anode rod every half year and change it if it has been used out For more details please contact the supplier or the after sale service E itis recommended to set a lower temperature to decrease the heat release prevent scale and save energy if the outlet water is sufficient m Clean the air filter every month in case of any affect on the heating performance e In terms of the filter set in air inlet directly namely air inlet without connect with canvas the method of dismantle the filter is anti clockwise unscrew the air inlet ring take out the filter and clean it completely finally remount it to the unit E Before shutting the system down for a long time please Shut down the power supply Release all the water in water tank and the pipeli
5. are divided into two categories In either case important safety instructions are listed to which close attention must be paid A WARNING Failure to observe a warning may result in death or serious Injury A CAUTION Failure to observe a caution may result in injury or damage to the equipment A WARNING E The water heating unit must be earthed effectively g A creepage breaker must be installed near the power supply Do not tear off the labels on the units for the purpose of warning or reminding A WARNING Ask the professional installer for installation of the air source heat pump water heating units improper installation may result in water leakage electric shock or fire Ask the professional service person for the repair and maintenance Improper repair and maintenance may result in water leakage electric shock or fire In order to avoid electric shock fire or injury if any abnormality is detected such as smell of fire turn off the power supply and call your service agent for instructions Never use the wire and fuse with wrong rated current Use of wrong wire or fuse may cause the unit to break down or a fire Do not insert fingers rods or other objects into the air inlet or outlet When the fan is rotating at high speed it will cause injury Never use a flammable spray such as hair spray lacquer paint near the unit It may cause a fire Never touch the air outlet or the horizontal blad
6. below are the operation temperature for each mode 1 Economy Mode 7 43 C g NOTE This mode should be used at the ambient temperature maintaining at 7 43 C While the ambient temperature below than 7 C the energy efficient would bocome low obviously we recommend you to using the E heat mode at this circumstance 2 Hybrid Mode 30 43 C 3 E heater Mode 30 43 C Mode Selection Different mode is designed to meet different demand and the following are recommended selections Economy Mode 7 43 C a continuous hot water demand below 250L 60 C Hybrid Mode 30 43 C a continuous hot water demand between 300L 350L 60 C E heater Mode 30 43 C a continuous hot water demand between 150L 60 C Self Protection Apparatuses When the self protection happens the system will be stopped and start self check and restart when the protection resolved When the self protection happens the buzzer will buzz in every other minute the ALARM indicator glitter and the display indicate the error code and water temperature alternatively Press CANCEL button for 3sec to stop the alarm All stop when the protection is resolved and error code disappears on the display In the following circumstances self protection starts Air inlet or outlet is obstacled The evaporation is covered with too much dust Incorrect power supply exceeding the range of 220 240V NOTE When self protection happen
7. cap Rated power AMPS Power supply Operation control Protection Compressor power E heater power Regrigerant Outlet water temp Water side exchanger Inlet pipe Dia Outlet pipe Dia Solar water outlet Solar water inlet Drain pipe Dia PT valve Dia 0b 09 gt d9 oO ro 2 oO 4 0b Z Max pressure Material Motor power Exchanger Outlet air type Dimension Water tank cap Net weight Fusible link type The test conditions 1500W 6 5A 220 240V 50Hz Auto Manual startup error alarm etc High pressure Protector Over load Protector Temp Controller amp Protector Electric Leakage Protector etc 850W 3000W R134a 1200g Default 55 C 38 60 Cadjustable Surface heat exchanger DN20 DN20 DN20 DN20 DN20 DN20 1 0MPa Hydrophilic aluminum fin inner groove copper tube 80W Vertical upflow air supply 650x1920mm 300L 123kg TSA 250VAC Test temperature 15 12 C DB WB Water temperature from 15 C up to 45 C 4300W 18 7A 3000W 13 0A Installation amp Owners Manual 17 Take back of electrical waste Information for Users to Disposal of electrical and electronic equipment private households Icon on the product or in the accompanying documentation means that used electric or electronic products must not be disposed together with domestic waste For the correct disposal of the product hand it over to a place for take back where it is collected free of
8. set up a running start time and a stop time When the start time is earlier than the stop time the unit will run between the set time When the start time is later than the stop time the unit will run between the start time today and the stop time next day when user set up on a running start time and a stop time at the same time the stop time will be delay ten minutes automatically Method for setting Press the TIME ON key the minute digit of the clock on the display starts flashing Press the UP and DOWN key you can adjust the minute f Installation amp Owners Manual 11 Press the TIME ON key again the minute digit stops flashing and the hour digit starts Press the UP and DOWN key you can adjust the hour Press the TIME OFF key the minute digit on the display starts flashing slowly Press the UP and DOWN key you can adjust the minute f Press the TIME OFF key again the minute digit stops flashing and the hour digit starts Press the UP and DOWN key you can adjust the hour Stop operation for about 10s flashing stops and TIME ON TIME OFF set is finished Fig 8 13 Cancel In the unlocked state press the CANCEL key for 1s the Time on and Time off function will be canceled Fig 8 14 NOTE Time on and Time off can not be set to the same time If they are the same the stop time will delay 10 minutes automatica
9. the lock indicator will blank out all keys could be used normally Co Fig 8 6 Clock Set The clock is for a 24 hour system and the initial time is 00 00 To make a better use of this unit it is recommended to set the time for accurate local time Every time powered off the clock will be reset to the initial time 00 00 Method for time set Press the CLOCK key the minute digit of the clock on the display starts flashing Press the UP and DOWN key you can adjust the minute f Press the CLOCK key again the minute digit stops flashing while the hour digit 6 Press the UP and DOWN key you can adjust the hour Press CLOCK key again or stop operation for about 10s flashing will stop and clock set is successful Fig 8 7 Mode Selection The unit is enhanced with three operation modes Economy Mode Hybrid Mode and E heater Mode Economy Mode The unit heats water only by compressor drive according to heat pump principle Used when the ambient temp is high Hybrid Mode The unit heats water not only by compressor drive but also by electric heater Used when the ambient temp is low or large amount of hot water is needed E heater Mode The unit heats water only by electric heater Used when the ambient temp is very low By default the unit operates in Hybrid Mode Change Press the MODE key operation mode will be shifted among the three modes in a cycle meanwhile the c
10. C it lights up operation for 1 minute all indicators will go out automatically except Water fill indicator flashing and tank s temp indicator lighting Buzzer will di ring when you press it When the tank is full please press the ON OFF key the Water fill indicator will stop flashing and you can continue to function other settings When all settings finished please press the ON OFF key again and the Water fill indicator will go out And then run the unit When the unit is running if there is no operation or malfunction for 20s the backlight of the display will go out automatically except operation model outlet temp lock indicator If there no operation for 1min the unit will lock automatically but the lock indicator would be right all time Disinfection mode unit will automaticly run disinfection mode every Friday at 23 00PM Display panel indicates this mode by showing CL Installation amp Owners Manual 9 Lock and Unlock In order to prevent wrong operation a special lock function has been designed If there is no operation for 1min the unit will be locked automatically and display the lock indicator When the unit is locked no keys can be operated Unlock At the locking status of Display long press the cancel key to remove it At the screen protection of Display press any key to active the Display and then long press the cancel key to remove it After remove the locking mode
11. USER S MANUAL SINCLAIR AIR CONDITIONING WARNING This unit is required reliable earthing before usage otherwise might cause death or injury Please ask skilled service persons for reliable earthing connection Your safety is the most important thing we concerned PARTS NAMES Air Outlet Air Inlet Filter Top Cover Evaporator Electronic Control Box Fan Assy Junction Box Cover Compressor Front Cover Display Rear Cover Junction Box PT Valve Anode Rod Water Outlet TCO TOD Solar Sensor Cover Front Decorative Board Cover Electric Heater Solar Water Inlet Electric Heater Solar Water Outlet Water Inlet Drain Pipe om NOTE All the picture in this manual are for explanation purpose only They may be slightly different from the heat pump water heaterr you purchased depand on model The actual shaped shall prevail CONTENTS PAGE PRECAUTIONS ACCESSORIES INSTALLATION LOCATION INSTALLATION PIPELINE CONNECTION DUGT CONNECTION WA 5 ELECTRIC CONNECTION OPERATING INSTRUCTION RUNNING AND CAPABILITY c cccesseeseeesseeeeeeeeeeeseeeetseeeseeeseeeeees 14 MAINTENANCE SPECIFICATIONS 1 PRECAUTIONS To prevent injury to the user or other people and property damage the following instructions must be followed Incorrect operation due to ignoring of instructions may cause harm or damage The safety precautions listed here
12. able to bear weight of the E In the water inlet side the One Way valve must be installed unit and suitable for installing the unit without increasing noise or vibration E ts normal if some water drops from the hole of PT valve during operation Bit if the water is in a great amount call your E The operation noise and air flow expelled shall not affect service agent for instructions neighbors After a long term use check the unit stand and fittings m No flammable gas is leaked nearby If damaged the unit may fall and result in injury l l _ 7 m It is convenient for piping and wiring Arrange the drain hose to ensure smooth drainpipe Improper drainpipe may cause wetting of the building furniture m fit is installed in indoor space it might cause indoor temp etc declined and noise disturbance Please take preventive measures for this Do not touch the inner parts of the controller Do not remove the front panel Some parts inside are m If the unit need to be installed on a metal holder make sure dangerous to touch and a machine malfunction may be they are insulated well and in accordance with local standard caused Do not turn off the power supply System will stop or restart heating automatically A continuous v power supply for water heating is necessary except service and maintenance CAUTION m Installing the equipment in any of the following places may lead to malfunction of the equipment if it is inevitable consul
13. charge By correct disposal of the product you can help to preserve valuable natural resources and help in preventing potential negative impacts to environment and human health which could be consequence of incorrect disposal of waste Ask for more details from local authorities nearest collection point in Waste Acts of respective country in the Czech Republic in Act no 185 2001 Coll in the wording of later regulations In case of incorrect disposal of this waste a fine can be imposed according to national regulations al x Manufacturer Sinclair Corporation Ltd 1 4 Argyll Street London W1F 7LD UK Supplier and technical support Nepa spol s r o Purkynova 45 612 00 Brno Czech Republic www hepa cz Toll free info line C 420 800 100 285
14. d shall be laid out neatly and properly without mutual interference or contacting the connection pipe or valve A WARNING E After wire connection is finished check it again and make Creepage Breaker near the power supply and must be effectively earthed 7 2 Electric Wiring Illustration 220 240V L L N 50 Hz T3 m T5U T5L Pe TH Control Panel T3 Tube Temp Sensor T4 Ambient Temp Sensor T5U Tank Temp Sensor upper T5L Tank Temp Sensor lower TP Discharge Temp Sensor upper TH Return air temperature sen ele Earthing Fig 7 1 Installation amp Owners Manual 8 OPERATING INSTRUCTION 8 1 Operation steps Before using this unit please follow the steps below Water Affusion If the unit is used for the first time or used again after emptying the tank please make sure that the tank is full of water before turning on the power Method see Fig 7 1 Open the cool water inlet and When water flows out from the water hot water outlet water outlet valve and water affusion is finished Open Close gt Open D Water Affusion a 1 Hot water outlet o A Cool water inlet Hot water outlet Water out Fig 8 1 CAUTION l After powered on the display lights up Users can operate the unit through the buttons under the display for different modes A CAUTION the old in case of water burn Emptying If the unit needs cleaning m
15. ers and solar coil All these three heating elements do not work together This unit has two temp sensors which are installed at the upper 1 4 and bottom 1 2 The upper one tests the upper temp the figure shows in the water temp table and the bottom one is used to test the lower water temp which will control the ON amp OFF of the unit no shows in the display panel outlet Upper sensor J Bottom sensor J electric heater Tank Coil Fig 9 1 e Economy Mode In this mode according to the water temperature setting heat pump in preference to electric heater Water outlet temp range 38 60 C running ambient 7 43 C e Hybrid Mode In this mode the system will adjust the working capabilities of e heater and heat pump according to the tank water temperature Water outlet temp range 38 60 C running ambient 30 43 C Installation amp Owners Manual 14 0E E heater Mode In this mode the compressor and the fan motor will not run but the e heater work only Water outlet temp range 38 60 C running ambient 30 43 T NOTE In the E heat mode only half tank of water i e 150L could be heat every time Defrosting during Water heating In the Economy Mode and Hybrid Mode if the evaporation frosts in a cold circumstance the system will defrost automati cally to keep effective performance 3 10 min Ambient Temperature The system s operation temperature is within 30 43 C and
16. es while the swing flap is in operation Fingers may become caught or the unit may break down Never put any objects into the air inlet or outlet Objects touching the fan of high speed can be dangerous Do not dispose this product as unsorted municipal waste Collection of such waste separately for special treatment is necessary The appliance shall be installed in accordance national wiring regulations The appliance should not be used by children without supervision If the supply cord is damaged it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard An all pole disconnection device which has at least 3mm separation distance in all pole and a residual current device RCD with the rating of above 10mA shall be incorpo rated in the fixed wiring according to the national rule DISPOSAL Do not dispose this product as unsorted municipal waste Collection of such waste separately for special treatment is necessary Do not dispose of electrical appliances as unsorted municipal waste use separate collection facilities Contact you local government for information regarding the collection systems available If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the groundwater and get into the food chain damaging your health and well being Installation amp Owners Manual 1 A CAUTION 2 ACCESSORIES
17. filter in there must be put forward to the air inlet of duct Fig 6 7 6 8 pD Filter Filter Owner should install S the filter by self and the mesh size is about 1 2mm Fig 6 7 Fig 6 8 To fluently drain condensate water from evaporator please install the main unit at a horizontal floor Otherwise please ensuring the drain vent is at the lowest place Recommending the inclination angle of unit to the ground should no more than 2 Installation amp Owners Manual 6 7 ELECTRIC CONNECTION 7 1 Specifications of Power Supply Table 7 1 Model Name SWH 35 300TS A CAUTION Power E T ea T 220 240V 50Hz E The power supply for the unit must be specialized according Mlin Diameter of Power to the rated voltage Line mm2 Earthing must be included in the power circuit And it must be Earth Wire mm2 connected with the effective external ground wire Manual Switch A Capcity Fuse 39 25 The wiring must be performed by professional technicians Creepage Breaker 30 mA S 0 1sec according to the circuit diagram e Please choose the power cable according to above table and E Set the electric leakage protector according to the relevant it should comply with local electric standard electric technical standards of the State e The power cord type designation is HOSRN F a The power cord and the signal cor
18. ion amp Owners Manual 13 Table 8 2 Display Malfunction Description EO Error of sensor T5U E1 Error of sensor T5L E2 Tank and Wired Controller communication error E4 Evap pipe temperature sensor error ES Ambient temperature sensor error E6 Discharge pipe temp sensor error y Heat Pump system error E8 Electric leakage protection Eg TH sensor condenser failure P1 System high pressure protection P2 Discharge pipe temperature overhigh protection P3 No current flowing in Compressor P4 Compressor overloaded protection P8 No current flowing in electric heater P9 Upper e heater overloaded protection LA Ambient temp is not fit for heat pumps change the mode to E heater mode If the errors happen please contact the supplier or after sale service 9 RUNNING AND CAPABILITY 9 1 Trial Running E Before running please check the following items first e Correct installation of the system e Correct connection of pipeline and wiring Leakage of the refrigerant pipeline tested e Efficient drainpipe e Complete insulation protection e Correct earthing e Correct power supply No obstacle outside the air inlet and outlet e No air in the water pipeline and all valve opened e Effective electric leakage protector e Sufficient inlet water pressure 20 15MPa 9 2 Operating Capability E Water heating Operating Capability e Heating elements are included in the unit one heat pump and one electric heat
19. ise and shaking will be resulted Make sure that there s no remora around the unit In the place where there is strong wind like seashore fix the unit in the location protected from the wind Carry the unit onto the site In order to avoid scratch or deformation of the unit surface apply guard boards to the contacting surface No contact of fingers and other things with the vanes Don t incline the unit more than 45 in moving and keep it vertical when installing This system is very heavy it need to be carried by 2 or more persons othewise might cause injury and damage Install the unit The circulating air for every unit should be more than 700m2 h Make sure there is enough Installation space Outline dimensional drawing see Fig 4 1 Fig 4 2 jo 650 mm Installation amp Owners Manual 3 P 650 mm Fig 4 2 Pipeline Connection Sketch User sling CLL cI tJ Z 2 Upper Condensate Outlet Lower Condensate Outlet i aig i A Notice the mixer tap is required Anode rod on the hot water usage terminal Solar sensor Solar water inlet Solar water outlet Y shaped Filter Tap Water lt j OneWay Valve Ball Valve Drainpipe a Thermal expansion tank if required Barrel drain Fig 5 1 CAUTION When install the main unit please set a drain valve at the drain orifice of the unit by self E Pipeline Connection Explanation e installati
20. ld be set at such circumstance Please switch to E heating mode manually for ensuring there s adequate hot water could be supplied if that so code is going to disappear and indicator alarm stop flashing any more all recover to be normal The light will glitter in error WII d ALARM Am aT Fig 8 17 Warning Code of disagree with heat pump mode Temp Set L re Fig 8 18 Error Shooting If some errors happen the buzzer will buzz 3 times every other minute and the ALARM indicator will glitter fast Press CANCEL for several seconds to stop the buzzer but the light will keep glittering The light will glitter in error Press CANCEL key to stop the buzzer Ce Fig 8 19 The error code from the screen of set Temp will display when malfunction happen the system display error code after one minute when press the key again and the screen display set temp Display the error code TEMP SET minke Fig 8 20 e When the economy mode happen malfunction the system can keep using after switching to E heater mode When some error happens though the system could be used in some circum stances it could not reach the expected efficiency Please contact your supplier for help Error Code Explanation See table 8 20 A WARNING The covers of the E heater should not be opened without guidance of professional technician in case of electric shock or any danger Installat
21. lly For example Time on and Time off set to 1 00 at the same time then the stop time will adjust to 1 10 automatically Time off function can not be used alone The key can be used only after setted the on time User can press the on off key manual beyond the timer range Power On and Power Off Press Power On Power Off button after all the above have finished and the system will run as the setting And simply press the same button to stop it Co Fig 8 15 Operation status The LA code from the screen of set Temp will appear and remind user when ambience temp not meet the operation condition of heat pump unit beyond 7 43 C User can sw itch the economy mode to E heating mode in sure of enough volume of hot water if need The unit will return operation pre status automatically in no any operation when the ambie nce temp meet the operation condition of heat pump mode and the error LA will be disappear at the same time the screen display nomally Installation amp Owners Manual 12 Warning Code of disagree with heat pump mode TEMP SET L ric Fig 8 16 In case of continual 20 hours when in the season ambient temperature doesn t meet for the heat pump operation requirement absent from the range 7 43 C LA will display at Temp Settings window and ALARM indicator flashing simultaneously alarming that the temperature doesn t suit for heat pump performance only E heating mode cou
22. ne and close all the valves e Check the inner components regularly mM How to Change the Anode rod a Turn off the power and turn off the water inlet valve e Open hot water tap and decrease the pressure of the inner container Open the temperature pressure valve and drain out the water until there are no water flow out of e Get off the anode rod according to instruction Replace with a new one and make sure effective sealed e Open cold water valve until hot water flows out and turn off the hot water tap e Restart and can be used normally 10 2 Non error Malfunction 3 min Protection With the power supplied an immediate restart after the shutting down will have to wait 3 min as to protect the compressor E If self protection happens and the system stops check When the power indicator lights up if the system is forced to run while startup requirement has not been met If the air outlet or inlet is jammed or strong wind blows to air outlet E Defrosting When it is humid and cold the evaporate may defrost and the water heating capacity decrease And the system will stop heating water and start defrosting and then restart water heating a During defrosting fan stops working four way valve reverses the flow direction and compressor keeps working e The defrosting time varies from 3min to 10min according to the ambient temperature and the frost a Temperature Display e When the sy
23. on of the water inlet or outlet pipes The spec of the water inlet or outlet thread is RC3 4 internal thread Pipes must be heat resistant and durable e Installation of the pipe for PT valve The spec of the valve connecting thread is RC3 4 internal thread After installation it must be confirmed that the drainpipe outlet is exposed in the air When flexible drainpipe is jointed to the pressure relief orifice of this valve it must be confirmed that the flexible drainpipe is downwards vertically and exposed in the air g NOTE e A safety valve should be installed at the water inlet of the unit e Arrange water pipes and which connected fittings as illustration of the above figure In case of install it at a place where outside temperature below freezing point insulation must be provided for all hydraulic components eThe handle of PT Valve should be pulled out once per half year to make sure that there is no jam of the valve Please beware of burn because of the high temperature of water The drainage pipe should be well installed in order to avoid freezing up in cold weather e Do not press the handle of PT Valve e Do not dismantle the PT Valve e Do not block off the Drainage pipe It will cause explosion and injury if do not comply with the above instruction EXPLOSION e Installation of the One Way Valve The spec of the One Way Valve thread in accessories is RC3 4 It is used to prevent backflow of
24. orresponding indicator on the display will light up Co Fig 8 8 Temp Set Temp displayed is the water temp in the upper part of the tank Default is 55 C and the Economy mode setting range is 38 60 C the Hybrid and E heater mode setting range is 38 60 C Method for set Installation amp Owner s Manual 10 Press the UP and DOWN key you can Increase or decrease the water temp Fig 8 9 When the set temp is higher than 50 C the HIGH TEMP indicator will light a h MAHIGHTEWP Z TASS Fig 8 10 Timer User can set up a running start time and a stop time on a specifically by the timer function The least numbers of timer is ten minutes Time on User can set up a start time by this The unit will auto run one time between the set time and 24 00 on the same day Method for set Press the TIME ON key the minute digit of the clock on the display starts flashing Press the UP and DOWN key you can adjust the minute f Press the TIME ON key again the minute digit stop flashing and the hour digit starts Press the UP and DOWN key you can adjust the hour Press the TIME ON key again and wait about 10s flashing stops and ON TIMER set is finished Fig 8 17 Cancel In the unlocked state press the CANCEL key 1s and the time on function will be canceled Fig 8 12 Time on and Time off Users can
25. oving etc the tank should be emptied Method See Fig 8 2 After emptying please replace the nut of drainpipe Close the cool water inlet open the hot water outlet and open drainpipe Open gt gt a Emptying i gt _ Close A SZ Hot water outlet Open Cool water inlet Drainpipe Drainpipe Fig 8 2 outlet the tank is full Turn off the hot Operation without water in water tank may result in damage of auxiliary e heater Due to such damage the supplier is not responsible for the quality issue Over 50 C may result in serious burn or so caused death Special care should be paid to the children the disabled and Installation amp Owners Manual 8 8 2 Operation steps Water temp indicator When the actual water temp exceeds 40 C it lights up OUTLET TEMP indicator It displays water temp OW of the upper part of the tank which can be used It always lights TIMER CONFLICT indicator When the temp you set through Wired Controller conflicts with that through User Interface it lights up Display A TIME OFF indicator It will light up when timing off mode is setted blanks when screen protection Oy TIME ON indicator It will light up when timing on mode is setted blanks when screen protection By CLOCK indicator It displays present time it will blanks when screen protection E HEATER MODE indicator When user sets the
26. r the water tank coil won t be over heated 6 DUCT CONNECTION WAY Note Upon connect canvas portion airflow and capacity in heat pump system will lose in the system E Air inlet and outlet no need to connect with canvas Air inlet without canvas air outlet connect to canvas A lt 10m Air outlet Air inlet Air outlet a Air inlet Fig 6 1 E Fig 6 3 Recommending Use it in where with surplus heat or indoor place in the winter where with surplus heat E Air inlet and outlet need to connect with canvas A B lt 10m E Air inlet connect to canvas air outlet without canvas A lt 10m A o A B Air outlet Air inlet Air outlet Air inlet lt a il Hl lt lt u O D Q Fig 6 4 Fig 6 2 Recommending In summer use this connection way could charge flesh air into room Installation amp Owners Manual 9 m Canvas Duct Description Other shaped canvas duct Round Rectangle canvas duct canvas duct Dimension 190X190 mm Straight line pressure drop Canvas Duct Pa m Refer to Straight line above data length m Bent pressure drop Pa Ben
27. s cut the power supply manually and restart after the error resolved m Water Temperature Display The temperature on the display is the water temperature in upper part of water tank over 1 4 which you will use but not that of all the water e The 6 indicators beside the water temperature on the display are the lower part water temperature When the temperature is higher than 40 C the blue one will light up when higher than 50 C the blue and yellow ones light up when higher than 60 C the blue yellow and red ones light up and when all light up the water temperature has reached the set point e In water using the temperature of the lower part may decrease while the upper part still Keeps a high one and the system will start heating the lower part And it is normal E Error Shooting e When common error happens the system enters Standby Mode and could still work but not so efficient as normal Please contact the technician e When serious error happens the system will be unable to carry on Please contact the technician e When error happens the buzzer will buzz in every other minute the Warning light glitter and the display indicate the error code and water temperature alternatively Press CANCEL button for 3sec to stop the alarm E Restart after Long Stop When the system is started after a long time trial running included it is normal if the outlet water is unclean Keep the tap on and it will be clean soon
28. stem stops a decrease of the temperature is normal as heat released When it decreases to some point the system will restart automatically e During water heating the displayed water temperature might still decrease or not increase for a period of time because of the heat exchange of the water When the whole tank of water has reached the set temperature the system will stop automatically 10 3 Malfunctions and Resolutions Table 10 1 e Bad connection of power supply plug and socket e Reconnect the MEIC o Outlet water is set an a low plug temperature Set outlet water an e Outlet water temperature a higher controller is damaged temperature e Circuit board of indicating Contact the indicator is damaged technician It ll return to normal after water supplied Use it when the pressure Is higher No hot e Tap water has been cut away Water pressure is too low e Inlet valve has been closed Open the inlet water valve water from the outlet EMRE The joints on the pipeline are Check and reseal CELERE not sealed well all the joints 10 4 After Sale Service If the unit runs to some malfunction or error it should be shut down and power supply cut off And then please contact your local service center or supplier for help Installation amp Owners Manual 16 11 SPECIFICATIONS Table 11 1 Model T 4 35 300TS Mode Economy Mode Mode Hybrid Mode E heater Mode 3000W 3000W Water heating
29. t the supplier e The site contains mineral oils such as cutting lubricant e Seaside where the air contains much salt e Hot spring area where corrosive gases exist e g sulfide gas e Factories where the power voltage fluctuates seriously Inside a car or cabin Installation amp Owners Manual 2 Place like kitchen where oil permeates Place where strong electromagnetic waves exist Place where flammable gases or materials exist Place where acid or alkali gases evaporate Other special environments Precautions before installation Decide the correct way of conveying the equipment Decide the correct way of conveying the equipment If the unit has to be installed on a metal part of the building electric insulation must be installed and the installation must meet the relevant technical standards for electric devices Installation space Before installing the unit reserve the space of maintenance shown in the following figure Air outlet Barrier Air inlet Display Fig 3 1 SN Fe CO T TELE 600mm 600mm rr Fig 3 2 4 INSTALLATION A WARNING Ask your supplier to install the air source heat pump water heating units Incomplete installation performed by yourself may result in a water leakage electric shock or fire The place without direct sunlight and other heat supplies If there s no way to avoid these please install a covering The unit must be securely fixed or else no
30. t s qty NOTE Canvas duct to be connected at air outlet better than at inlet WARNING am E Upon connect canvas portion airflow and capacity in heat pump system will lose in the system a For the case of main unit connect with canvas the diameter of the duct must 2190mm total length of the ducts should not longer than 10m or the maximum static pressure should not exceed than 50Pa Be in mind of the bending site of the duct no more than 5 s For main unit air outlet connects with canvas when main unit operating condensate dew be generates at the outside of air outlet canvas Please pay attention to the discharge of conden sate water We suggest you to wrap the thermal insulated layer at the outside of air outlet canvas mi Recommending install the main unit at indoor ambient It is not allow to install the unit at outdoor or rain achieving place 44 efdal PRP OW ye a F 44414 PAP PY Rain Main unit Fig 6 5 y Warning In case of rain entering to internal components of the main unit the component might be damaged or causing physical danger Fig 6 5 E In terms of the main unit connect with canvas reaching to outdoor a reliable water resistant measure must be conduct on the duct resist water drop into internal of the main unit Fig 6 6 E Filter installing at the main unit inlet In terms of the main unit connect with canvas
31. water e Installation of the Y shaped filter The spec of the Y shaped filter thread in accessories is RC3 4 It is used to filtrate inlet water e After all the pipes installed turn on the cool water inlet and hot water outlet and start effusing the tank When there is water normally flowing out from water outlet the tank is full Turn off all valves and check all pipes If there is any leakage please repair If the inlet water pressure is less than 0 15MPa a pressure pump should be installed at the water inlet For guarantee the long safety using age of tank at the condition of water supply hydraulic higher than 0 65MPa a reducing valve should be mounted at the water inlet pipe e Probably may cause water leakage because of blockage during the drainage pit is suggested to use a water collector as instruction in Fig 5 2 Heat Pump Max 22mm Water Heater T 20MM larger tha the dia of HPWH Fig 5 2 E Solar Energy Coil Electrical Control Instruction m The mainboard of machine has two dedicated ports use for connecting to the solar thermal they are CN17 ON OFF port and CN18 Feedback port The ports ensure heat pump and solar thermal won t work together m Among them the CN17 ON OFF port is used for receiving the control signal of the solar energy water heating system this signal needs to be voltage free switch signal When the control signal is closing signal the heat pump system will be locked and can