1. MS300 User Instructions 14 4 RS 232 Communications Protocol 4 0 RS 232 Communications protocol Type EIA RS 232C RS 232 Half duplex Asynchronous Transmission interface Baud rate 2400 4800 9600 19200 O L o g gt RS232 Jack Data Bits 8 Parity N 7 Stop bits 1 La s ie Data Transmission Format DID D D D D D uU U U U U IF amp D Weight U Weight unit Format of Date Communication 16 Byte blank communication lt 20H gt lt STX gt lt Status gt lt gt lt D gt lt D gt lt D gt lt D gt lt D gt lt D gt lt D gt lt U gt lt U gt lt U gt lt U gt lt U gt Description of Date Communication 1 STX Start of Transmission 02H 2 2BH Positive Weight 2DH Negate Weight 3 DDDDDDD Value of Weight 7ASCII Code 4 UUUUU Weight Units kg Ib oz St 5 ASCII Code 5 LF 07 6 CR 0D 7 EXT Stop of Transmission 03H For instance Err Transmit 16 Byte lt Status gt lt STX gt lt X gt lt E gt lt r gt lt r gt lt 20H gt lt 20H gt lt ETX gt 100 02kg lt STX gt lt P gt lt gt lt 20H gt lt 1 gt lt 0 gt lt 0 gt lt gt lt 2 gt lt 20H gt lt 20H gt lt 20H gt lt K gt lt g gt lt ETX gt MS300 User Instructions 15 5 Procedure of Fabricating 5 0 Assembly Procedure for the MS300 1 Screw the four adjustable feet into the holes located on the bot
2. Press g to toggle between kg lb oz MS300 User Instructions 8 2 Weighing 2 1 Hold function This function enables you to weigh oversized objects that may obscure the display The system calculates an average weight reading and displays this weight value This makes the hold function ideal for weighing individuals that may be moving around on the platform 0 j a l amp Q sat 2 O Lar ca Load Weight 5 When the annunciator stops flashing the weight is displayed and remains even when the load is removed O a ro al ro co jm al amp gt lt 9 MS300 User Instructions 2 Weighing 4 To cancel the hold 0 co cy MS300 User Instructions 10 3 Setup mode Setup mode 3 1 Function setup In setup mode you can configure the following functions e weighing unit e auto shut off Battery mode e calibration weight Auto shut off switches off the scale if no activity is sensed during the period set The time values are in seconds To disable auto shut off select GFF Calibration weight allows you to select full load 0 5 load or 0 25 load of the machine capacity for calibration The table lists the actual weight value you should use Weighing Full load 1 3 load 1 4 load units kg 200 kg 100 kg 50 kg Ib 500 Ib 200 Ib 100
3. Ib Calibration weights 11 MS300 User Instructions 3 Setup mode Press TARE Yy Set AA Unit_ gt A OFF gt GrAv gt TrAn gt On gt On OFF 1500 gt 3000 5000 1H ie e Fu 250a 30o 780 240 300 I e On gt On GFF Setup menu Navigating the setup menu 1 Press and hold till display shows Set approximately three seconds 2 Release display shows Unit UNITS 3 Press wx tO move across to the option or value you require 4 Press A to select an option and save To exit the setup menu and save your changes Press uy unit you see End Press to save your changes and return to weighing fA a mode MS300 User Instructions 12 3 Setup mode 3 2 Calibration 1 In steup mode select the CAL option and then select whether you want to use 1 full or 1 4 load for calibration See Calibration weights on page 11 The example shown in these instructions uses kg weight unit and 1 load Save your selection and then switch off the scale ZERO S0 lt At the same time ax X 3 13 MS300 User Instructions 3 to select alternate units UNITS kg x 3 Setup mode
4. exceed the weighing capacity of the machine Pluggable equipment must be installed near an easily accessible socket outlet Permanently connected equipment must have a readily accessible disconnect device incorporated in the fixed wiring For your protection all mains 110V or 230V equipment used out of doors or in wet or damp conditions should be supplied from a correctly fused source and protected by an approved RCD to BS7071 or BS7288 or BS4293 The mains lead must be connected to a supply outlet with a protective earth contact The electrical supply at the socket outlet must provide overcurrent protection of an appropriate rating IF IN DOUBT SEEK ADVICE FROM A QUALIFIED ELECTRICIAN Safe use To avoid the possibility of electric shock or damage to the A machine always switch off the machine and isolate from the power supply before carrying out any routine maintenance Cleaning the machine CAUTION Harsh abrasives solvents scouring cleaners and alkaline cleaning solutions such as washing soda should not be used especially on the display windows Under no circumstances should you attempt to wipe the inside of the machine MS300 User Instructions The outside of standard products may be wiped down with a clean cloth moistened with water containing a small amount of washing up liquid or disinfectant EMC compliance The following warning may be applicable to your machine this product may cause radio interference
5. in which case the i WARNING This is a class A product In a domestic environment user may be required to take adequate measures MS300 User Instructions 1 About your machine 1 About your machine 1 1 Description The MS300 is a self contained portable platform scale with a remote display The platform is constructed of mild steel it has four adjustable feet for levelling For best results always install the platform on a hard flat level surface A stainless steel platform version is available 1 2 Display SALTER Brecknell naill O ON OFF X UNITS ZERO Hda O Oooo oO ol e D D Doz 5 cE 300 kg x 0 1kg 660lb x 0 2Ib MS300 O Stable neta t weight Minus a Hold weight i Centre of zero Ib weighing mode ith Low battery kg weighing mode 1 3 Key functions a Zero ON OFF key Switches the scale on or off Zero the value Tare key Applies a tare value MS300 User Instructions 4 1 About your machine a Units key G Hold key 1 4 Error codes Err Overload ErrL Below zero ErrE EEprom error Selects weighing units Retains average weight display a Low battery warning 1 5 Specification Capacity resolution Display Operating temperature Weight Dimensions Platform Display head Power supply Recharge adaptor 300kg x 0 1kg 660lb x 0 2Ib Height 25mm 7 segment LCD 52C to 352C 25kg 550mm x 550mm x 940mm 270mm x 90mm x 45mm 6 x 1 2V metal hydride rech
6. SALTER GSALTER MS300 Platform Scale User Instructions ENGLISH 76103 578 Issue 1 27 04 2003 Salter Brecknell Weighing 2002 All rights reserved The information contained herein is the property of Salter Brecknell Weighing and is supplied without liability for errors or omissions No part may be reproduced or used except as authorised by contract or other written permission The copyright and the foregoing restriction on reproduction and use extend to all media in which the information may be embodied MS300 User Instructions Declaration of Conformity Safety Warnings Safe installation Safe use Cleaning the machine EMC compliance 1 About your machine 1 1 Description 1 2 Display 1 3 Key functions 1 4 Error codes 1 5 Specification 2 Weighing 2 1 Hold function 3 Setup mode 3 1 Function setup 3 2 Calibration 4 RS 232 Communications Protocol 5 Procedure of Fabricating 5 1 Move Contents page no WNNNN uh RR BR 10 10 12 14 15 19 MS300 User Instructions SALTER GSALTER CE Declaration of Conformity Manufacturer Salter Brecknell Type MS300 corresponds to the requirements of the following EC directives EMC Directive EMC 89 336 EEC Low Voltage Directive LVD 73 23 EEC The applicable harmonized standards are EN60950 EN50081 1 EN50082 1 A copy of the origi
7. argeable batteries 120V AC 15V DC MS300 User Instructions 1 6 MS300 User Instructions 1 About your machine Power supply The indicator head contains six metal hydride re chargeable batteries The low battery indicator fy is displayed when the battery power is insufficient to power the scale Recharging the batteries Insert the AC re charger adapter into the socket on the base to recharge the batteries tes Recharging time is approximately 14 hours Fully charged batteries should give approximately eight hours of continuous use CAUTION Always connect the AC adaptor to the indicator head before connecting to the mains power supply Disconnect from the mains power supply before disconnecting the adaptor from the indicator head AC adaptor The Input 120VAC Output 15VDC 300mA recharge adaptor supplied with the MS300 provided Oe 2 Weighing 2 Weighing Forbest results always weigh ona hard flat and level surface The platform has four adjustable feet for leveling ZERO Press to switch on the scale The display will show 8888 then go to weighing mode If the display does not show ZERO o o or press gt 0 lt Zero Full Capacity 2 ZERO To switch off the scale press and hold 0 lt 1 If necesssary zero the scale 7 MS300 User Instructions 2 Weighing Using tares Weighing units
8. feet to be suspended See figure 6 2 Pull the scale to the desired location 3 Tilt the scale back up onto its adjustable feet Note Only use the wheels for moving the scale short distances j Figure 6 MS300 User Instructions 20 Email Email sales salterbrecknell co uk sales salterbrecknell com SALTER GSALTER P O Box 9533 Smethwick West Midlands B66 2TE Tel UK 0870 444 6132 Fax UK 0870 010 2241 Salter Brecknell Weighing Products 1000 Armstrong Drive Fairmont Minnesota 56031 USA Tel 507 238 8702 Fax 507 238 8271
9. nal signed declaration for this instrument is available from Salter Brecknell Weighing P O Box 9533 Smethwick West Midlands B66 2TE Electromagnetic Compatibility Statement for North America This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions manual may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment to an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help MS300 User Instructions Safety Warnings Safe installation Take care when lifting and transporting heavy objects Do not overload the machine Take care not to
10. tom of the platform See figure 1 Figure 1 2 Screw two vertical stainless steel support rods into the platform opposite each other See figure 2 e 8 Figure 2 MS300 User Instructions 16 5 Procedure of Fabricating 3 Insert the male plug from the indicator into the remaining stainless steel support rod making sure the male plug exits out the opposite end of the support rod See figure 3 eee E P E i i aad i i RI Al Figure 3 MS300 User Instructions 17 5 Procedure of Fabricating 4 Connect the male plug with the female connector See figure 4 5 Insert the last vertical stainless steel support rod into the center mounting hole on the platform See figure 4 Figure 4 MS300 User Instructions 18 5 Procedure of Fabricating 6 With the horizontal handrail positioned above the three support rods insert the middle post of the hand rail into the middle support rod See figure 4 and 5 7 Insert the ends of the handrail into outer support posts See figure 5 Assembly is now complete I lt gt gt Sa a Na e ra P oe p ia Ll ia Figure 5 MS300 User Instructions 19 5 Procedure of Fabricating 5 1 Moving the Scale 1 Tilt the scale back onto the wheels far enough for the four adjustable