RTR-52Pt Manual_EU_02.indd

image

Contents

1. Place the RTR 52Pt unit face down on the A RTR 57U After downloading you can save the data into files and folders create graphs make data tables create text file format files for use with popular Communication Port 4 About the LCD Display Recording Status REC LIT UP displayed during recording or when FULL of data BLINKING displayed when waiting for a programmed recording to start Low Battery Life Warning Indicator Displayed when time to change the battery Unit of Temperature Measurement select from C Celsius or F Fahrenheit Temperature Measurement Display This is displayed under the following conditions after purchasing and putting in the batteries for the first time if the battery terminals were mistaken and a short occurred or if the batteries are replaced after having been taken out for a long period If this is displayed all data that had been stored in the main unit has been erased Full Memory m c If recording under the ONE TIME MODE when the data readings reach the E n L upper limit of 16 000 readings recording will stop and this will be displayed intermittently with the current temperature Wireless Transmission 5 E a This will be displayed when transmitting data to an RTR 57U unit via wireless Ic communication No Sensor Connected m Displayed when a sensor has not been connected or the wire has been broken Measurement and recording will continue and
2. We sincerely hope that the contents of this manual are true and complete If you find any information to have been omitted or if the information within is confusing or mistaken please contact your retailer or T amp D Corporation Microsoft Windows and WindowsNT are registered trademarks of Microsoft Corporation USA and are binding in the USA and all other countries Company names and product names are trademarks or registered trademarks of each company The Warranty that comes with this Manual can not under any cicumstance be reissued so please keep it in a safe place The Manual itself can be downloaded from our Website http www tandd com Please carefully observe the following safety measures when using our product To prevent any loss or damage to our customers other people and or property and to ensure the proper use of our products we ask that before using our product you carefully read understand and follow the safety rules and precautions for our products as outlined below Explanation of Warning Symbols These entries are actions that absolutely under no A DANG ER circumstance should be taken The taking of such an action may cause serious personal physical damage or death A Cc AUTION These entries are actions that if taken may lead to physical injury or damage to persons or things Explanation of Picture Symbols This symbol denotes an important warning or caution Inside or near the symbol will a
3. battery power consumed Measurement Over Range Temperature display blinks when the temperature goes below 199 9 C or above 600 C While blinking measuring and recording still continue However note that the displayed temperature should be used only as a rough guide When the temperature cannot be displayed a blinking sign will appear Emirs 26 OLE Note Use in cold environments may cause the display to be difficult to read this is not a malfunction For details about the display during battery changing see 5 Changing Batteries 5 Changing Batteries NOTE After removing the old batteries replace them with new batteries within 1 minute 1 When the battery power becomes low the BAT indicator will appear on the LCD display Once the BAT indicator appears please change the battery as soon as possible Recording OK mee R REC o Wireless Communication OK ra Ce Za aCe Data Download OK bo l l Le 6 The recorded data will remain saved If at this time a new battery is placed in the unit recording will continue After changing the battery the BAT indicator will disappear in a short time 2 If you do not change the battery and continue using the unit the temperature display will intermittently display bAtt Please change the battery at once Recording OK m Wireless Communication No Data Download No pem es en his The recorded
4. Accessories Included Lithium Battery LS14250 SAFT X 1 Tube X 1 Strap X 1 User s Manual Warranty X 1 1 Not for continued immersion 2 The water resistance rating with the sensor adaptor connected is IP64 3 Radio commnication can not be operated at below 30 C degrees or less Notices about this User s Manual Please read this manual carefully before using the product All rights of this User s Manual belong to T amp D Corporation It is prohibited to use duplicate and or arrange a part or whole of this User s Manual without the permission of T amp D Corporation Please follow the safety precautions carefully We cannot guarantee nor are we responsible for safety if this product is used in any manner other than was intended T amp D Corporation accepts no responsibility for any malfunction of and or trouble with this product or with your computer that is caused by the improper handling of this product and will deem such trouble or malfunction as falling outside the conditions for free repair of the attached warranty T amp D Corporation accepts no responsibility for any result or effects from using this User s Manual Safety Precautions and Instructions Figures and illustrations in this manual may be slightly simplified and may differ from the actual product On screen messages figures or illustrations in this manual may vary slightly or be simplified from the actual messages and product
5. EU The latest version software can be downloaded from our Website Pay attention to water leakage or foreign objects entering into the unit case as in the following cases The case was closed with dust hair etc on the rubber packing or in the groove for the packing The rubber packing was damaged In this case please purchase the optional maintenance set The unit suffered from significant temperature change while wet especially if the temperature change was from high to low Do not use or store the unit in places such as listed below It may cause electrocution fire or damage to the unit or to your computer Areas exposed to direct sunlight Areas exposed to water or high pressure water flow Areas exposed to organic solvents corrosive gas and oils Areas exposed to strong magnetic fields Areas exposed to static electricity Areas exposed to fire or overheating Areas exposed to excessive dust or smoke A When using Sensor Adaptor RTR 05P1 please take note of the following This sensor adaptor is not waterproof Only use in an environment where there is no condensation or possibility of wetness When connecting the sensor please follow the connection diagram on the terminal block Please make sure to securely tighten the screws to the terminal block so as there is no chance of becoming unfastened A Cracks may develop in the unit casing if it comes into contact with hazardous substan
6. Ls Bwhite A Red 3 Connect the Sensor Adaptor to the RTR 52Pt Logger s Sensor Jack Make sure that the sensor is properly connected by inserting it until you hear a clicking sound The RTR 52Pt factory default sensor type is Pt100 In order to use a Pt1000 sensor change the settings using the software T amp D Recorder for Windows that is provided with RTR 57U Data Collector Units Please use the latest version of the software NOTE When changing batteries make sure to carefully read 5 Changing Batteries Upon first installation of the batteries measuring and recording will automatically begin at the factory set default recording settings Recording Interval 10 minutes Endless Mode Immediate Start After replacing the batteries the settings will return to the most recent recording settings If necessary make changes to the default recording settings according to your usage and needs If you are going to be using wireless communication it is necessary to register the Group Name and Remote Unit Name information at this time See 3 Settings and Communication Sensor Jack aa Sensor Adaptor 3 Settings and Communication To start and stop recording make or change the various recording settings and or collect data please see the following instructions For details about how to change settings and about communications please see the User s Manual that co
7. Wireless Thermo Recorder RTR 52Pt Warranty Customer s name 12 months from date of purchase Date of purchase 0 Statement of Limited Warranty 1 This product is warranted to be free from defects in materials and workmanship for a period of one 1 year following the date of purchase Should the product fail to operate per specification in normal use during this period T amp D will repair the unit or provide a replacement free of charge T amp D will not accept returns for any reason other than defects during the warranty period and will not accept any product that has been misused dropped abused or inappropriately used or mistreated at any time 2 This warranty is strictly limited to repair or replacement in kind for defective product T amp D makes no other warranty either express or implied and will not accept liability beyond the remedies stated herein Specifically T amp D will not accept liability for direct indirect special consequential or incidental damages arising from the use of this product 3 Customers wishing to submit a defective product for repair or replacement during the warranty period should first contact the dealer from whom it was originally purchased After receiving a return authorization the defective product should then be packaged along with a description of the difficulties being experienced proof of purchase and all included accessories and materials and returned it to the dealer In the event of di
8. ces such as oil products When using the unit in such an environment protect the unit by placing it inside a polyethylene bag Wireless Thermo Recorder RTR 52Pt 1 Outline Thermo Recorder RTR 52Pt is a Data Logger designed to be used with a platinum resistor Pt100 Pt1000 sensor for measuring and recording temperature The data recorded with the RTR 52Pt can easily be downloaded via special short wave wireless communication to an RTR 57U Data Collector where the data can be saved Then it is possible to download the data to your computer for data analysis and management with our exclusive software Communication between units can be done via optical communication as well as wireless communication Basic Functions of RTR 52Pt E Wireless Communication Function Via special short wave radio communication recorded data can be downloaded from an RTR 52Pt unit and saved to the RTR 57U Data Collector Unit Recording settings and recording start can also be controlled via wireless communication RTR 57U Wireless Communication can occur between an RTR 52Pt Unit and an RTR 57U Unit within a range of up to about 100 meters if unobstructed and direct NOTE In order to collect data via wireless communication it is necessary to register via Setting the Recording Conditions The recording conditions include Recording Mode Recording Interval Start Recording Date and Time and Unit of Temperature Detailed instructions on how to
9. change these settings are provided in the User s Manual for either the Recording Mode Select from two types of Recording Mode ONE TIME MODE When the data capacity of 16 000 readings is reached the LCD display will indicate FULL and recording will stop ENDLESS MODE When the data capacity of 16 000 readings is reached the data will be erased in order from the oldest data first and recording will continue Below is an estimate of the amount of time it will take for the unit to become FULL in the ONE TIME MODE Calculation Example 30sec recording interval x 16 000 readings capacity limit 480 000 seconds about 5 days and 13 hours Downloading Data Data Collection spreadsheet software and print graphs and tables E Setting Upper and Lower Limits By making upper and lower limit settings you can check your recorded data as it is downloaded for data that exceeds the set limits Part Names and Functions Terminal Block computer the RTR 52Pt unit as a Remote Unit in the RTR 57U Unit you wish to use For details about making these settings please see the Help Menu in T amp D Recorder for Windows or the User s Manual for T amp D Recorder for Windows Wide Temperature Measurement Range The RTR 52Pt with a platinum resistor Pt100 Pt1000 sensor can measure and record in a wide range of 199 9 to 600 C NOTE By starting a new recording all data previously stored in th
10. data will remain saved If at this time a new battery is placed in the unit recording will continue and downloading of saved data can be done After changing the battery the temperature display will return to displaying only the temperature after which the BAT indicator will disappear a short time later 3 If you do not change the battery even under conditions in 2 above the REC indicator will disappear and temperature display area will display SLP SLP stands for Sleep Mode Recording No BAT o Wireless Communication No ror c Data Download No l L J Recording will stop and recorded data until this point will be saved If at this time a new battery is placed in the unit downloading of saved data can be done To start recording again please set the recording conditions via your computer or RTR 57U and begin recording See 1 Outline After changing the battery the temperature display will return to displaying the temperature 4 If you do not change the battery even under conditions in 3 above the display will go blank All of the recorded data will be erased If at this time a new battery is placed in the unit CHEC will appear on the display after which recording will begin again using the previously set recording conditions
11. e data logger unit will be erased Recording Interval 1 second 30 seconds 15 minutes 60 minutes Ti iod 4 hours 5 days 166 days 1 year 10 Wire erteorder APREA 26 min 13 hours 16 hours months E Starting and Stopping Recording You can make settings to control the starting and stopping of recording CDS oca if you want to save the data make sure to download it and save it in an RTR 57U Unit or in your computer before starting a new recording 2 Getting Started Insert the batteries 1 Remove the screws and take off the back case Make sure to use the proper size and type of screwdriver A 1 Slot Screwdriver is best compatible with these screws 2 Insert the battery in its tube and place in unit as in diagram Make sure that and are correct Make sure no water or foreign objects get inside the case If dirt or scratches are present on the rubber packing water resistance will be reduced Be sure to fasten the cover tightly Make sure not to over tighten the screws Tightening Torque About 20N cm 30N cm 2kgf cm 3kgf cm If nothing appears on the LCD Display please follow the above instructions again Connect the Temperature Sensor 1 Loosen the screws of the terminal block Back 2 Connect the sensor terminals to the terminal block as instructed in the diagram on the terminal block Bik Bcwhite Securely tighten the screws to the terminal block _
12. fficulty contacting the original dealer customers should contact the nearest authorized T amp D sales representative A list of these can be found on the company s website www tandd com or it can be obtained by contacting TandD US directly 4 This limited warranty statement gives the customer specific legal rights The customer may also have other rights which vary from state to state in the United States from province to province in Canada and from country to country elsewhere in the world To the extent this limited warranty statement is inconsistent with local law this statement shall be deemed modified to be consistent with such local law 5 For further information relating to product repair or replacement or for other service questions after the termination of the warranty period customers should contact their local authorized T amp D sales representative MO A Wireless Regulations ME Radio EMC and Safety Regulations C RTR 5 Series complies with technical specifications required under EN 301 489 3 with battery and AC Adaptor EN 300 220 3 and EN 60950 2000 Allowed to use in A B D DK F I P S SW UK N NL CH FIN AUS NZ Inquiries T amp D CORPORATION 5652 169 Sasaga Matsumoto City NAGANO 399 0033 JAPAN Tel 81 263 27 2131 Fax 81 263 26 4281 E mail overseas tandd co jp Website http www tandd com Wireless Thermo Recorder RTR 52Pt Wireless Temperature Data Logger User s Manual Thank yo
13. fully aware of this before using our product This product has been designed for private or industrial use only It is not for use in situations where strict safety precautions are necessary such as in connection with medical equipment whether directly or indirectly Do not drop or expose the unit to strong impact The case material of this unit is susceptible to certain organic solvents and oils such as vegetable oil Prolonged exposure to these substances can cause cracking of the case and will void the manufacturer s warranty When using this unit in environments where such oils are present please insure that it is protected from contact through use of a polyethylene bag or other means gt gt Do not put your fingers or foreign matter into the sensor connection Battery terminals may provide insufficient contact due to age or vibration Please be careful not to lose data due to insufficient contact Battery life depends on the measurement environment communication frequency recording interval and battery quality Remove batteries from any unit that is not to be used for a long period of time Batteries left in a unit not being used for a long time may leak and cause a malfunction Avoid using the lithium batteries LS 14250 for long periods at temperatures over 60 C The battery life may be significantly decreased gt OO OO Operate the units with the latest version of T amp D Recorder for Windows RTR 5
14. mes with the RTR 57U You can also find detailed information in the User s Manual that accompanies the software Thermo Recorder for Windows and in the Help Menu of the software Using Wireless Communication with an RTR 57U Unit By registering an RTR 52Pt unit as a Remote Unit of an RTR 57U it is possible to carry out wireless data communication special short wave radio allowing you to start and stop recording make recording condition settings and collect data without having to handle the RTR 52Pt units If you are going to be using wireless communication it is necessary to register the Group Name and Remote Unit Name information in the RTR 57U units The wireless communication range if unobstructed and direct is about 100 meters In some cases communication cannot take place even within 100 meters Please check first by carrying out the wireless communication test with the remote units Optical Communication with an RTR 57U By simply placing an RTR 52Pt unit face down on an RTR 57U you can carry out recording start settings and changes as well as collect recorded data via optical communication Place the RTR 52Pt unit face A down on the RTR 57U Communication with your Computer By placing an RTR 52Pt unit face down on an RTR 57U unit that is connected to your computer you can make any necessary recording conditions settings and changes start recording and download recorded data easily via your computer display
15. ppear another symbol giving details EX A stands for ELECTROCUTION This symbol denotes a forbidden action Inside or near the symbol will appear another symbol giving details EX stands for DO NOT TAKE APART This symbol denotes an action that you must take Inside or near the symbol will appear another symbol giving details EX stands for TAKE PLUG OUT OF SOCKET a A DANGER Do not take apart repair or modify the main unit It may cause fire electrocution or damage Ask the shop where you purchased the products or T amp D Corporation to carry out any repairs If any smoke or strange smells are emitted from the unit immediately cease using it Continued use may cause fire electrocution or damage gt Do not use any batteries other than those that are recommended It may cause fire or damage gt If water or a foreign object enters the case immediately cease using it Store all batteries sensors and Thermo Recorder units out of the reach of children It is dangerous to swallow batteries touching the units may cause burns or frostbite The RTR 52Pt is a devices to measure temperature Do not use this unit for any purpose other than temperature measurement ys Please be careful when using in overly hot or cold environments SS A CAUTION We are not responsible for any malfunction or trouble caused by the use of our product or by any problem caused by the malfunction of our unit Please be
16. u for purchasing this product Carefully read and fully understand these instructions before using this unit T amp D corPorRATION Copyright 2007 T amp D Corporation All rights reserved 2007 11 16004504040 Product Specifications Coo T a SOS Measurement Display 01C Resolution 0 3 C 199 9 to 80 C Measurement Accuracy 0 5 C 80 to 450 C ato 50 C 1 0 C 450 to 600 C Sensor accuracy is not included 1 2 5 10 15 20 30 seconds 1 2 5 10 15 20 30 60minutes Total of 15 choices Endless Overwrite oldest data when capacity is full One time Stop reading when capacity is full Current Readings Recording Settings Battery Life Warning Over Measurement Range Warning Unit Lithium Battery LS14250 SAFT X 1 Approx 6 months Battery life depending on measurement environment recording interval and battery performance ETSIEN 300 220 Up to 100 meters May vary with conditions Wireless Communication RTR 57U Optical Communication RTR 57U When downloading data Wireless Approx 2 000 readings per minute Collection of a full unit of data Approx 420 seconds optical communication Approx 160 seconds Water Resistance 1 IP64 rated for use in daily life 2 Recording Interval Dimensions H62 x W47 x D19mm excluding protrusions antenna length 20mm Approx 56g including 1 lithium battery Unit Temp Resistance 40 C to 80 C 3 Sensor Adaptor RTR 05P1 X 1