1. 03 Directional Specifications 31 Introduction Important Warning Thank you for selecting the Martin Cyclo 03 Directional The Cyclo 03 Directional is a dynamic fluorescent color changing luminaire that can be programmed for stand alone operation or controlled via DMX The Cyclo 03 Directional is designed for dynamic color illumination of walls and surfaces A patented optical system ensures effective color mixing within the main reflector allowing the luminaire to be positioned close to the illuminated surface without color hot spots Dimmable T5 fluorescent tubes combine high efficiency bright color and long lamp life The Cyclo 03 Directional can be surface mounted or mounted on standard 3 phase lighting track It can be tilted through 250 allowing flexibility of installation Control cables are through wired for easy installation The Cyclo 03 Directional features e Controllable RGB color mixing e Full 0 100 intensity control of the red green and blue tubes e High output long life T5 fluorescent tubes Flexible mounting options 250 of tilt Read this manual before attempting to install this product The most recent version of this user manual is available from the Support area of the Martin Architectural website at http www martin architectural com Safety information This product is for professional use only It is not for household use These products present risks of lethal
2. examples show how an individual luminaire s program is made up of scenes The following symbols are used in program diagrams Tube turned fully off Fade in Fade out Fade to 50 and back to 100 in one scene applies when only one color is active and crossfading is selected Example 1 DIP switch 7 is set to ON crossfading and only red is activated Red PII sone TEIT Cyclo O3 Directional user manual Example 2 DIP switch 7 is set to OFF blackout fading and only red is activated Red 1 7 IN T INTZINTZINIZISTZIN ane aa 2112 112021141 Example 3 DIP switch 7 is set to ON crossfading and red and blue are activated mee MANISES MA ASS Blue IN ZINIZINIZINIZINIZINTZ Scene 1 21 2112 11 211 2 1 2 Example 4 DIP switch 7 is set to OFF blackout fading and red and blue are activated Red eee Blue AN ASE TS Scene 1 2 3 4 1 2 3 08 1 2 3 4 Example 5 To achieve a rainbow effect activate red green and blue and set DIP switch pin 7 to ON crossfading SARA TASAS Gs EAN ANSIA GES Blue NIZ N ZN N A Scene 1 2 3 1 2 3 1 2 3 1 2 3 Activating master slave stand alone operation To activate master slave stand alone operation 1 Power all luminaires off 2 Set all luminaires as slaves and put them into stand alone mode by setting DIP switch pins 9 and 10 to ON 3 Decide which luminaire to use as master and set this luminaire s DIP switch pin 9 to O
3. in the order red then green then blue This means that if red is activated it will always be first in the program If red is not activated but green is activated green will be first in the program Each luminaire follows the program set on its own DIP switch as described in Table 1 Stand alone DIP switch settings on page 14 More sophisticated light shows can be programmed using a DMX controller see DMX controlled operation on page 21 The synchronization signal used by the Cyclo 03 Directional is identical to that used in other 3 tube Cyclo luminaires allowing these products to be combined in master slave operation on one data link However it is not compatible with 4 tube Cyclos Consult your Martin Architectural dealer if you need advice on combining and controlling products Identical light shows Master and slave luminaires can be set to behave identically In this mode the master sends synchronizing signals to the slaves and all luminaires run the same light show Each slave luminaire follows the program set on its own DIP switch so for identical operation all luminaires DIP switch settings must be the same apart from pin 9 which is set to ON for slaves and OFF for the master Synchronized non identical light shows It is also possible to synchronize changes but program slave luminaires to behave differently from the master To use this feature effectively you need to plan your light show using scenes as bu
4. to signal cold e pin 1 to signal hot DMX controller i Master i i i Slave Lin Lee p d Slav Termination plug Termination plug DMX control link Master slave link Cyclo O3 Directional user manual Tip To create the data link 1 Use suitable cable to connect one of the RJ 45 sockets on the first Cyclo 03 Directional to an RJ 45 socket on the next luminaire 2 Continue connecting up to 32 luminaires using the RJ 45 sockets 3 Terminate the link by inserting a an RJ 45 DMX termination plug P N 91613028 in the RJ 45 data output of the last luminaire 4 If using a DMX control device use suitable cable to connect the device s DMX output to one of the RJ 45 sockets on the first Cyclo 03 Directional Random flicker and other unexplained control problems during stand alone master slave operation can often be cured by inserting an RJ 45 DMX termination plug into the unused socket of the first luminaire Burning in fluorescent tubes Optimum tube performance is obtained after burning in new fluorescent tubes for 100 hours at full power Installation 13 Stand alone operation 14 In stand alone operation the Cyclo 03 Directional can be used without a DMX controller Static single colors or two color mixes can be displayed or luminaires can be programmed to c
5. 63 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 419 420 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 Table 2 DIP switch address settings DMX controlled operation 23 Controlling via DMX The Cyclo 03 Directional s advanced fluorescent tubes can be dimmed from maximum output right down to zero using three channels on a DMX controller This allows a wide range of color shades with almost infinitely variable intensity to be obtained using additive color mixing The color temperature of white light can also be fine tuned Depending on the functions available on the controller sophisticated light shows on the Cyclo 03 Directional can be programmed over time allowing constantly and rapidly shifting color mixes or color displays which change slowly according to the time of day or even year for example See the con
6. 7 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 21 PD PD MH NM NM KM ND P 2 52 5 OO NOU Pom CH 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 WWWWW WWW W a gt Sn SE GO OO 4 OO Om POND 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 3
7. Defective luminaire Bypass luminaires one ata time until normal operation is regained Poor quality light output and or color rendering Tube or tubes not burnt in Run luminaire for at least 100 hours to burn in tubes Tube defective Troubleshooting Disconnect luminaire and replace tube 29 DMX protocol Start code 0 Channel Value Percent Function Red intensity 1 0 2 0 Tube off 3 252 1 99 Intensity 1 100 253 255 100 Intensity 100 Green intensity 2 0 2 0 Tube off 3 252 1 99 Intensity 1 100 253 255 100 Intensity 100 Blue intensity 3 0 2 0 Tube off 3 252 1 99 Intensity 1 100 253 255 100 Intensity 100 30 Cyclo O3 Directional user manual Cyclo 03 Directional Specifications PHYSICAL L x W x H with mounting arms 1200 x 107 x 285 mm 47 3 x 4 2 x 11 2 in L x W xH without mounting arms 1200 x 107 x 218 mm 47 3 x 4 2 x 8 6 in Weight TR EE ie ae ai 8 7 kg 19 3 Ibs Luminaire colors Titanium white SOURCE Light ele oo sana eee ead ia T5 fluorescent tubes 3x54W Approved lamp type OSRAM T5 high output 54W Color authenticity Guaranteed to 10 000 hours Averagetubelife 20 000 hours DYNAMIC EFFECTS 0 100 dimmabletubes Red green and blue CONTROL AND PROGRAMMING Control options DMX512 sta
8. FF Note that any luminaire can be set as master but Stand alone operation 19 20 you will obtain the most reliable data signal by either setting the first luminaire on the link as master or using RJ 45 DMX termination plugs at both ends of the data link When power is applied slave luminaires will go to the next scene in their program each time the master goes to its next scene Slave luminaires will also start scene 1 of their programs each time the master starts scene 1 of its program Cyclo O3 Directional user manual DMX controlled operation The Cyclo 03 Directional may be programmed and operated with any lighting control device that is compatible with the USITT DMX standard See also DMX protocol on page 30 Connecting a DMX control device Connect a data cable to the DMX control device s data output and one of the Cyclo 03 Directional s RJ 45 DMX sockets If your control device has an XLR data output socket you may need to buy or wire an XLR to RJ45 converter For details of wiring and polarity see Data linking multiple luminaires on page 12 Setting a luminaire to DMX operation DMX operation is enabled by setting pin 10 on the DIP switch to OFF Pins 1 9 are then used to set the luminaire s control address Setting a DMX control address The Cyclo 03 Directional uses 3 DMX control channels The DMX address also known as the start channel is the first of these channels It must be set on th
9. al user manual 4 The diffuser is held in place by metal clips at each end of the luminaire Push a clip back and remove the diffuser You now have access to the tubes 5 Pressing on the metal caps at both ends of the tube rotate the tube 1 4 turn in whichever direction is easiest and slide the tube s terminal pins out of their sockets Support the tube at both ends as it is released 6 To install a new tube line it up so that the manufacturer s markings on all tubes are at the same end of the luminaire Slide the tube s terminal pins fully into their sockets and rotate the tube 1 4 turn to engage the pins Check that the tube is held securely in the sockets 7 Replace the diffuser and then the reflector by pushing them onto their clips before reapplying power Service 27 28 Tube positions Tube positions in the Cyclo 03 Directional are identified as follows Marking in Marking on luminaire tube Reference illustration R OSRAM FQ 54W 60 RED paa E OSRAM FQ ke 54W 66 GREEN B OSRAM FQ 54W 67 BLUE RGB da The burning positions of fluorescent tubes affect their operating temperature light output and tube life For best results Install tubes so that the manufacturer s markings are all atthe same end of the luminaire If the luminaire is mounted in a vertical position or at an angle from the horizontal place the ends of the tubes that carry the manufacturer s markings at the low
10. e luminaire and selected on the DMX controller before the controller can send commands to the luminaire via a DMX link The Cyclo 03 Directional responds to commands sent to the DMX address and the next two channels If the DMX address is set to 100 the Cyclo 03 Directional uses channels 100 101 and102 Allow enough channels when setting the DMX address If control channels for one luminaire overlap control channels for another luminaire one of the luminaires will receive the wrong commands If two or more Cyclo 03 Directionals share the same DMX address they will receive the same commands and respond identically Individual control will be impossible DMX controlled operation 21 The default factory set control address is 1 To set the Cyclo 03 Directional s DMX address 1 Set DIP switch pin 10 to OFF 2 Decide on a DMX address for the luminaire If you are calculating the DMX addresses for multiple fixtures save time by using the online Martin Address Calculator at http www martin dk service utilities AddrCalc index asp see illustration below Jii eet tig fe ma eid See dere pir Gm J SCH 4 Mad mit WP Rek E SE Ki Kraft ge rege 3 You can also look up DIP switch settings using the Martin DIP Switch Calculator available for use and downloadable at http www martin dk service dipswitchpopup htm If you do not have Internet access refer to Table 2 DIP switch address settings on page 23 TE aA i
11. er end of the luminaire Cleaning Turn off power to the luminaire before cleaning and use a damp cloth to wipe clean Cyclo O3 Directional user manual Troubleshooting Problem Probable cause s Remedy No response from fixture when power is applied In stand alone mode DIP switch pin 8 set to ON pause Set DIP switch pin 8 to OFF to resume stand alone program No power to luminaire Check power connections No power to lighting track Check power connection to lighting track Ground fault protection circuit breaker RCD has tripped Reset RCD If problem persists have an electrician replace the RCD or reduce the number of fixtures powered via one RCD Fixture does not respond correctly to DMX control Controller not connected Check DMX data link Inspect connections and test cables Repair or replace as necessary Incorrect DMX addressing Check address setting on fixture and controller Data link not terminated Insert RJ 45 termination plug in unused socket of last fixture on data link Two devices transmitting on link Check that all luminaires are set as slaves DIP switch pin 9 ON Defective luminaire Bypass luminaires one at a time until normal operation is regained Fixtures do not behave correctly in master slave mode Two luminaires transmitting on link Check that only one luminaire is set to operate as master
12. h Latte gt ea rma Limas ide Martin OIP 5 4 Set DIP switch pins 1 through 9 to ON 1 or OFF 0 with reference to the table 22 Cyclo O3 Directional user manual Find the address in the table Read the settings for pins 1 5 to the left and read the settings for pins 6 9 above the address 0 means OFF and 1 means ON Pin 10 is always OFF for DMX operation For example to set the DMX address to 101 you need to set DIP switch pins 1 3 6 and 7 to ON The DIP switch settings for Channel 101 are highlighted in the table DIP switch Setting 9 8 0 OFF 7 1 0N 6 ojojojo ojojo o ojojo ojoj o zl OO oj gt o al o ojoj o O O oj So O ojol Oo aja oa il 3 N gt a OoOoa0 0 oa 200 20000 O op CH CH CO OOOO A 20 CH o 235220000 m o EH E o e SAOOOO OOR gt 2020202300 200000000 20 CH N O So E o OF off F o 5 o oF of Aa EA AA AR AR ch ch ch ch ch AA AA he E E CH CH E CO OO OO CO CH 20 GO OHNOUOPOLND gt gt HN _ gt Si a N N GO OO JO Om PBUUND LO N N NM ND N GA PD O 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 4 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 6
13. hange colors in cycles Changes can be programmed at 1 5 10 or 30 second intervals Two stand alone operation modes are available In single stand alone operation luminaires run independently of each other No data link is required In master slave stand alone operation luminaires must be linked Synchronized action in all luminaires is triggered by one master luminaire In both single and master slave stand alone operation luminaires are programmed via the pins on the DIP switch on the luminaire s housing as shown in Table 1 Pin Function 1 Red active 2 Green active 3 Blue active 4 Not used 5 amp 6 Program speed Pin 6 Pin 5 Speed OFF OFF 1 sec steps fastest setting OFF ON 5 sec steps ON OFF 10 sec steps ON ON 30 sec steps slowest setting OFF Blackout fading ON Crossfading OFF Run program ON Pause program OFF Master ON Slave Note do not set more than one luminaire as master 10 ON Stand alone mode Table 1 Stand alone DIP switch settings Cyclo 03 Directional user manual A quick reference table covering DIP switch functions is also provided on the back cover of this manual Stand alone operation settings Activating colors DIP switch pins 1 to 3 each activate a color in the stand alone program Setting program speed Combinations of DIP switch pins 5 and 6 allow one of four different speeds to be set Fading between colo
14. he same RCD as the live conductor Cyclo 03 Directional luminaires incorporate four electronic ballasts that leak a total current of between 0 8mA and 4mA to ground earth Luminaires must be correctly connected to ground so that this leakage current can be absorbed It is also important that installation is carried out correctly in order to avoid unintentional tripping of the RCD ground fault circuit breaker Because of the leakage current we recommend connecting a maximum of seven Cyclo 03 Directional luminaires per phase when circuits are protected by a 30mA RCD Bear in mind that some RCDs rated at 30mA may trip when current leakage to ground is as low as 20mA Connecting to mains power Cyclo 03 Directional luminaires have an ENSTO male connector built into the casing for mains power input A female ENSTO connector is supplied with the luminaire for installation on the power supply cable Cyclo O3 Directional user manual To draw power from lighting track a suitable power take off plug from the lighting track supplier must be installed on the power supply cable in accordance with the lighting track supplier s instructions Some common color coding systems for mains wiring is given below Wire EU Wire US Pin Marking blue white neutral N yellow green green ground sl When installing the female ENSTO connector on the power cable note the markings next to the screw terminals T
15. he terminal marked 1 must be connected to the live wire The centre terminal marked must be WI connected to the ground earth wire eed The terminal marked N must be connected O di the neutral wire The following connectors and cables are available from your Martin dealer ENSTO 3 pole 16A 250V male connector P N 05347202 ENSTO 3 pole 16A 250V female connector P N 05327202 ENSTO male female cable 15 cm 5 9in P N 11501019 Installation 11 Data linking multiple luminaires You need to create a serial data link to e Operate two or more Cyclo 03 Directionals in master slave stand alone mode where all luminaires run a synchronized light show without a separate DMX control device e Control luminaires with a DMX control device A reliable data connection requires suitable cable CAT 5 category 5 UTP unshielded twisted pair network cable is suitable for this purpose Your Martin Architectural dealer can advise and supply suitable cable Luminaires on a serial data link must be daisy chained in one single line maximum 500 meters 1640 ft long with maximum 32 luminaires To exceed 32 luminaires or 500 meters or to add branches an optically isolated amplifier splitter such as the Martin RS 485 Opto Splitter P N 90758060 must be used Data cable can be connected to the Cyclo 03 Directional via RJ 45 sockets that are wired as follows e pins 7 amp 8 to ground earth e pin 2
16. ilding blocks and set the luminaires DIP switches accordingly A scene is a change from one ouput to another When a luminaire is in slave mode it starts a scene when it receives a synchronization signal from the master The time taken by the scene is determined by the speed setting of the DIP switch A slave will not respond to new synchronization signals until its scene is complete Stand alone operation 17 When crossfading is selected each color takes up one scene fade in only When blackout fading is selected each color takes up two scenes fade in and fade out This means that a maximum of 6 scenes can be programmed with all 3 colors activated and blackout fading selected Each time the master luminaire starts at scene 1 it sends a signal to all the slave luminaires to start at scene 1 This means that if a slave luminaire has 1 Fewer scenes than the master luminaire it will run these in a cycle until the master luminaire signals that the program should start from the beginning again 2 More scenes than the master the additional scenes will never run because the program will reset to the first scene when the master starts its program from the beginning Here is an example of what will happen when a slave luminaire has fewer scenes than the master luminaire Luminaire setting Scene pattern Master with 6 scenes 123456 123456 123456 Slave with 4 scenes 123412 123412 123412 Program examples The following
17. martinarchitectural Cyclo O3 Directional user manual Dimensions Measurements are in millimeters 1100 1135 u L 1200 Al 2004 Martin Professional A S Denmark All rights reserved No part of this manual may be reproduced in any form or by any means with out permission in writing from Martin Professional A S Denmark Printed in Denmark P N 35000163 Rev B Contents Introduction sm Aves ot eed each 5 Safety information 5 Installation aan 7 MIN ar er et leeren Drake kurs 7 AT WE ed Me RE ai heats GR RA ern 10 Data linking multiple luminaires 12 Burninginfluorescenttubes 13 Stand alone operation 14 Stand alone operation settings 15 Single stand alone operation 16 Master slave stand alone operation 16 DMX controlled operation 21 Connecting a DMX control device 21 Setting a luminaire to DMX operation 21 Controlling DAA WA KUA eee 24 SERVICE Aa IA a a aided Geese Sua 25 Fluorescent tube replacement 25 SUIER EE N HR EO ace 28 Troubleshooting 29 DMX protocol 30 Cyclo
18. naires installed Block access below the work area whenever installing servicing or removing the luminaire Cyclo O3 Directional user manual Installation Warning This section describes in general terms how to install the luminaire connect it to AC power and connect control data cables These procedures must be performed by qualified professionals Mounting The Cyclo 03 Directional features two mounting options track mounting on standard 3 phase lighting track e surface mounting using mounting brackets that are available as accessories Check that all fasteners structures and surfaces used to mount the Cyclo 03 Directional can bear the total weight of all devices installed Work from a stable platform and block access below the work area when installing or servicing luminaires above head height Lighting track mounting The Cyclo 03 Directional can be mounted on lighting track from all major manufacturers Nokia Erco Zumtobel iGuzzini Nordic Aluminium etc Installation 7 A 3mm Allen key is required for this operation To mount a Cyclo 03 Directional on lighting track 1 Isolate the lighting track from the power supply and ensure that power cannot be reapplied even accidentally 2 Hold the luminaire up to the lighting track and slide the ends of the mounting arms into the slot in the track 3 Supporting the luminaire in position fully tighten the 3mm Allen screws in the side of each mounting a
19. nd alone master slave Receiver N EE EE cea ed bbe eee ead RS 485 Setting and addressing DIP switch Data input output RJ 45 through wired Number of DMX channels 3 INSTALLATION 3 phase lighting track mounting with universal track adaptor Surface mounting with optional mounting brackets Orientations EE bao alr ee ely RO RR are ped Any Minimum free space around luminaire 25 mm 1 inch THERMAL Maximum ambient temperature Ta 40 C 104 F Maximum total heat dissipation 618 BTU hr COOLING MEN ls RE a ee a re E Convection POWER AC power wee ec eves a ee Be 198 V 254 V 50 60 Hz Maximum power and current 208 V 50 Hz 0 87 A 180 W Maximum power and current 230 V 50 Hz 0 80 A 181 W Maximum power and current 250 V 50 Hz 0 73A 179W AG INPUt aces taa tl ne EnstoNet Installation System Cyclo 03 Directional Specifications 31 32 CONSTRUCTION HOUSING it Ca ee tee Base Mild steel Optics tcc EE High specular 99 9 aluminum INCLUDED ITEMS Red T5 high output fluorescent tube OSRAM FQ 54W 60 Green T5 high output fluorescent tube OSRAM FQ 54W 66 Blue T5 high output fluorescent tube OSRAM FQ 54W 67 ENSTO 3 pole 16A 250V male connector P N 05347202 ENSTO 3 pole 16A 250V female connector P N 05327202 User
20. niantial 3 EET ER 20 ra Sse ar eye P N 35000163 ACCESSORIES Wall ceiling bracket set of 2 titanium P N 91611187 Wall ceiling bracket set of 2 white P N 91611186 Termination plug RJ 45 P N 91613028 RJ 45 connector 15 cm 5 9 in P N 11840088 ENSTO male female cable 15 cm 5 9in P N 11501019 XLR male to RJ 45 converter P N 11840087 XLR female to RJ 45 connector P N 11840086 50 x CAT5 network cables 2 m 6 5 ft P N 91611044 30 x CAT5 network cables 5 m 16 4 ft P N 91611045 15 x CAT5 network cables 10 m 32 8 ft P N 91611046 ORDERING INFORMATION Cyclo 03 Directional titanium P N 90550055 Cyclo 03 Directional white P N 90550050 Cyclo O3 Directional user manual 8 ON Pause OFF Play 9 ON Slave or DMX 3 Blue OFF Master 2 Green 10 ON Stand alone 1 Red OFF DMX 6123456 4 Not used 7 ON Crossfading OFF Blackout fading 5 6 Program speed Quick reference Cyclo 03 Directional DIP switch settings y wiartin www martin architectural com e Olof Palmes Alle 18 e 8200 Aarhus N e Denmark Tel 45 8740 0000 e Fax 45 8740 0010
21. or severe injury due to fire and heat electric shock and falls Read this manual before powering or installing these luminaires follow the safety precautions listed below and observe all warnings in this manual and on the luminaires If you have questions about Introduction 5 how to operate these luminaires safely please contact your Martin dealer or call the Martin 24 hour service hotline at 45 70 200 201 Protection from electric shock Disconnect the luminaire from AC power before removing or installing a tube or any part and when not in use Always ground earth the luminaire electrically Use only a source of AC power that complies with local building and electrical codes and has both overload and ground earth fault protection Ensure that the luminaire s live and neutral conductors are both connected to the same RCD ground fault circuit breaker Do not expose the luminaires to rain or moisture Refer all service to a Martin service technician Protection from burns and fire Provide a minimum clearance of 0 1 meters 4 inches around the luminaire Do not modify the luminaire or install other than genuine Martin parts Do not operate the luminaire if the ambient temperature Ta exceeds 40 C 104 F Protection from injury due to falls Ensure that all components and installation fittings are securely fastened Ensure that all supporting structures surfaces and fasteners can bear the weight of all lumi
22. rm 4 Check that the luminaire is held firmly in place before reapplying power Lighting track dimensions can vary slightly between manufacturers If the Cyclo 03 Directional is not held firmly in place you may need to repeat the above procedure adding the square spacers supplied with the luminaire to take up any clearance between the mounting arms and the lighting track Cyclo O3 Directional user manual Surface mounting The Cyclo 03 Directional can be surface mounted on a floor wall or ceiling using a bracket kit that is available as an accessory To surface mount the Cyclo 03 Directional 1 Ensure that the surface on which you want to mount the Cyclo 03 Directional can support the weight of all the luminaires installed on it 2 Mark up two points 1100mm 43 3 in apart as center points for the mounting brackets Allow enough space around the center points for the 110mm 4 3 in square cover plates ai Ce AN si 1100 BRACKET COVER Lomo 3 Hold each mounting bracket against the mounting surface so that the raised ridge in the bracket runs at 90 to the long side of the Cyclo 03 Directional see illustrations and so that the center point you have marked is visible in the middle of the rectangular hole in the center of the bracket 4 Mark the mounting surface using the holes at the corners of each bracket as guides and drill holes in the mounting s
23. rs If DIP switch 7 is set to OFF blackout fading colors fade to almost blackout before the next color fades in If DIP switch 7 is set to ON crossfading color fading overlaps If two or more colors are active one color fades in while another is fading out giving a color mixing effect For example if red and blue are activated and crossfading is selected colors will crossfade from red through purple to blue then back through purple to red in a continuous cycle see example 50 Blue Example crossfading between red and blue Stand alone operation 15 Important 16 Setting a static color display In stand alone operation a static non changing color display can be set by pausing the program at the point where it is showing the desired color Either one color or a mix of two colors can be frozen in this way To set a static color display 1 Activate the color you wish to display if you wish to display a two color mix activate these two colors on DIP switch pins 1 to 3 2 Set the luminaire as master by setting DIP switch pin 9 to OFF 3 Set DIP switch pins 5 and 6 to ON to activate the slowest program speed 4 Set DIP switch pin 7 to OFF to activate crossfading and DIP switch pin 8 to OFF to activate the program 5 When the desired color or color mix appears pause the program by moving DIP switch 8 to ON This color will remain frozen until DIP switch 8 is moved to OFF Note that the pa
24. troller s manual for details Your Martin Architectural dealer can advise about available controllers and control options Service With long life fluorescent tubes and no moving parts the Cyclo 03 Directional is almost service free Fluorescent tube replacement The Osram high output T5 tubes fitted as standard meet color specifications for at least 10 000 hours after which color intensity may gradually fall Average tube life is 20 000 hours but note that tube life will vary depending on operating conditions No tools are required to replace a fluorescent tube on the Cyclo 03 Directional The reflector and diffuser must be removed for access to the tubes These two components are attached to the luminaire housing by safety wires and can be left hanging from these wires during tube replacement Diffuser Reflector lt gt Service 25 26 To change a tube 1 Isolate the luminaire from the power supply and N ensure that power cannot be reapplied even Y accidentally 2 Ensure that the luminaire is securely mounted before SS beginning any servicing se gt work 3 The reflector is held in place by metal spring clips Hold the second fin from each end firmly and pull downwards to release the reflector If the reflector is difficult to move by pulling insert a small screwdriver between the reflector and the housing next to the second fin from the end to help release the clip Cyclo O3 Direction
25. urface for the fasteners 5 Fasten the mounting brackets to the surface using eight high tensile grade 8 8 or over M5 fasteners screws masonry bolts etc Note that the ridge in the bracket must be at 90 to the long side of the luminaire Installation Warning Important 10 6 Clip the bracket covers over the brackets with the long side of the rectangular hole at 90 to the Cyclo 03 Directional 7 Hold the luminaire up to the mounting brackets Slide the ends of the mounting arms through the rectangular holes in the bracket covers and into the mounting brackets 8 Carefully supporting the luminaire fully tighten the 3mm Allen screws in the side of each mounting arm 9 Check that the luminaire is totally secure AC power It is the installer s responsibility to ensure that all local safety regulations and legal requirements are observed when installing and connecting the Cyclo 03 Directional AC mains power compatibility and consumption data are given in the Specifications section on page 31 Many installations use common neutral conductors in branch circuit distribution boxes The neutral lead in the cable must be connected to the same RCD ground fault circuit breaker as the live lead in the cable If it is not users are left unprotected from the risk of potentially lethal electric shock It is the installer s responsibility to ensure that the Cyclo 03 Directional s neutral conductor is connected to t
26. used color is lost when the luminaire is powered off When powering the luminaire on again DIP switch pin 8 must be moved to OFF before the program will start Single stand alone operation In single stand alone operation a luminaire runs its own program independently of all other luminaires To do this the luminaire must be set as a master Activating single stand alone operation To activate single stand alone operation 1 Set DIP switch pin 10 to ON activates stand alone mode 2 Set DIP switch pin 9 to OFF activates master mode 3 Apply power and program the luminaire using DIP switch pins 1 8 see Table 1 Stand alone DIP switch settings on page 14 Master slave stand alone operation Do not set more than one luminaire on a data link as master and do not set a luminaire as master on a data link with a DMX Cyclo O3 Directional user manual controller Doing so may cause damage to the electronics that is not covered by the product warranty In master slave stand alone operation one master luminaire transmits a synchronizing signal to slave luminaires over the data link each time it starts a new action Slave luminaires start their next programmed action when they receive this signal from the master luminaire Programs can be identical on all luminaires or luminaires can subject to certain practical constraints run programs that are synchronized but not identical Note that e Colors are always displayed