Home
UZ934-H
Contents
1. For prompt and complete service information always refer to the model type and serial number indicated on the rating plate SAVE THESE INSTRUCTIONS GROUNDING INSTRUCTIONS This appliance must be grounded If it should malfunction or A breakdown grounding provides a path of least resistance Figure for electric current to reduce the risk of electric shock This A appliance is equipped with a cord having an equipment grounding conductor and grounding plug The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and WARNING e Grounding blade is Improper connection of an eguipment grounding conductor longest of the th can result in risk of electric shock Check with qualified ree blades electrician or service person if you are in doubt as to whether the outlet is properly grounded Do not modify the plug provided with the appliance If it will not fit the outlet have proper outlet installed by a gualified technician Grounded outlet box This appliance is for use on a nominal 120 volt circuitand has Figure a grounding plug that looks like the plug illustrated in Figure B A A temporary adaptor which looks like the adaptor illustra ted in Figure B may be used to connectthis plug to a two pole receptacle as shown if a properly grounded outlet is not available The temporary adaptor should be used only until a properly grounded outlet F
2. UZ 934 Dry Vacuum Cleaner INSTRUCTIONS FOR USE MODE D EMPLOI 822 2744 030 Printed in Sweden by AB m lstryck 2000 03 Edition NA2 WARNING HEPA filter must be installed while working with hazardous materials Failure to do so will expose people in the work area and others to hazardous materials which is a serious health risk ATTENTION Le filre Hepa Doit tre en place quand on travaille avec des substances dangereuses Si l on n utilise pas le filtre les personnes se trouvant sur le lieu de travail ou proximit sont expos es aux substances dangereuses et donc de graves risques de sant EMPTYING If this vacuum cleaner is used to collect hazardous material do not attempt to open or empty its contents without personal protective clothing and respiratory protection VIDAGE Si cet aspirateur est utilis pour ramasser des substances dangereuses ne jamais tenter de l ouvrir ou de le vider sans porter des v tements protecteurs et une protection des voies respiratoires a Pa IMPORTANT SAFEGUARDS THIS VACUUM CLEANER CAN BE USED FOR HOUSEHOLD OR COMMERCIAL USE ACCIDENTS DUE TO MISUSE CAN ONLY BE PREVENTED BY THOSE USING THE MACHINE READ AND FOLLOW ALL SAFETY INSTRUCTIONS WARNING To reduce the risk of fire electric shock or injury please read and follow all safety instructions and cauti
3. ch as gasoline or use in areas where they may be present Do not allow it to be used as a toy Close attention is necessary when used by or near children Use extra care when cleaning on stairs Caution Do not pick up hazardous material without Hepa filter mounted All contact with the machine dustbag filter and all other accessories used when picking up hazardous materials should be handled according to the regulations valid for the vacuumed material Do not use unless filters are fitted If the cleaner is not working properly or has been dropped damaged left outdoors or dropped into water return it to a service center or dealer Use only as described in this manual and only with the manufacturer s recommended attachments The use of this machine in conjunction with the pick up of hazardous materials has not been investigated by Under writers laboratories BEFORE YOU PLUG IN YOUR CLEANER check the rating plate at the rear of the cleaner to see if the rated voltage agrees within 10 of the voltage available Connect to a properly grounded outlet only See Groun ding instructions SERVICE INFORMATION To obtain consistent performance over the life of your vacuum read through these instructions and keep them handy for future reference Ifyou require service contactthe dealer from whom the vacuum was purchased or the local authorized Service Station Always refer to your Service Station for complete service information
4. igure A can be installed by a Grounded outlet box gualified electrician The green colored rigid ear lug or the like extending from the adaptor must be connected to a permanent ground such as a properly grounded outlet box cover Whenever the adaptor is used it must be held in place by a metal screw NOTE In Canada the use of a temporary adaptor is not permitted by the Canadian Electrical Code Grounding tab 1 To open a Pull the fasterners on the cover outwards b Lift the cover from the container 2 Dust bag Fit the opening on the dust bag over the air inlet Press the membrane over the flanged edge on the inlet Secure with the lock washer Use only original dust bags 3 Hose connection a Press the hose into the opening until it clicks b Unlock the hose by pressing down on the catch above the opening 4 Wand assembly a Standard To connect the wand sections together simply insert one section into the other giving the two assembled sections a firm push b Telescopic optional Adjust the length of the telescopic wand by pressing its button and altering the wand length When vacuuming stairs it is recommended that the wand is adjusted to its shortest length 5 Tools The accessories shown in the pictures may vary from model to model a Universal nozzle for both hard floors and carpets b Floor nozzle one way for brush hard floor or smooth for carpet c Crevice Tool designed for cleaning i
5. n narrow spaces like furniture radiators corners and joints d e Combi Brush Nozzle useful tool for the cleaning of upholstery stair carpets curtains etc 6 Suction control The suction control in the hose handle lets you regulate the air flow to prevent the nozzles from fastening to the surfaces you are vacuum cleaning 7 Start Stop 8 Filter The UZ 934 is avaliable in 2 different models a standard model and a Hepa model a Cartridge filter Makes operating without a bag possible Check the filter when you empty the container Change or clean if it is clogged Clean the filter by brushing or shaking it b Hepa filter Traps 99 99 of all particles larger than 0 3 microns Hepa filter should always be installed when picking up hazardous materials Never clean the filter if it has been used for picking up hazardous materials Change if it is clogged c Pre filter It is advisable to use the pre filter and dustbag together with the Hepa filter as they catches the big particles and extends the lifetime of the Hepa filter Pull the pre filter over the standard or Hepa filter The pre filter can be cleaned by washing or shaking it If washed let the pre filter dry completly before re installed Never clean the filter if it has been used for picking up hazardous materials 9 Exhaust filter a Lift the grill at the back edge b Pull it outwards Replace the used filter and snap the grill back in place 10 Warning Ne
6. on markings before use This vacuum cleaner is designed to be safe when used for cleaning functions as specified Should damage occur to electrical or mechanical parts the cleaner and or accessory should be repaired by the manufacturer or competent servi ce station before use in order to avoid further damage to the machine or physical injury to the user Do not use outdoors Do not leave the machine when it is plugged in Unplug from the outlet when not in use and before servicing Do not use with damaged cord or plug To unplug grasp the plug not the cord Do not handle plug or cleane rwith wet hands Turn off all controls before unplugging Do not pull or carry by cord use cord as a handle close a door on cord or pull cord around sharp edges or corners Do not run cleaner over cord Keep cord away from hea ted surfaces Keep hair loose clothing fingers and all parts of the body away from openings and moving parts Do not put any objects into openings or use with opening blocked Keep openings free of dust lint hair and anything else that could reduce the flow of air Do not pick up liguids Do not use the machine in wet environments Do not handle the plug or the machine with wet hands When cleaning the machine unplug from the outlet and use a dry cloth Do not pick up anything that is burning or smoking such as cigarettes matches or hot ashes Do not use to pick up flammable or combustible liquids su
7. ver attempt to vacuum liquid glass fragments or ashes Wet surfaces can expose the operator to possible electrical shock IMPORTANT The UZ 934 is equipped with a specially designed cable which if damaged must be replaced by a cable ofthe same type These cables are availiable at authorized service shops and must be installed by trained personnel The UZ 934 is eguipped with a thermal cut out to protect the motor and other vital machine parts from overheating Should the machine cut out you will have to wait at least 5 10 minutes for it to automatically reset While you are waiting switch the machine off and unplug it then check the hose dust bag and filters to be sure that nothing is blocking the flow of air through the machine NB Remove the plug from the socket before performing service or maintenance
Download Pdf Manuals
Related Search
UZ934 H uz934 vacuum
Related Contents
User Manual for the Pochoir Stencil Compiler Industrial Mobility: How Modern Factories Will Hotel Operations Guide - Advanced Communications Riverina Netgear XAVB5004-100NAS User's Manual manual Avaya SLIM-GRIP SM427 User's Manual Soleus Air SPTAC-12H User's Manual Sun Enterprise 420R Server Service Manual Copyright © All rights reserved.