1. Warning Maximum 300V USB connection to Read user guide Phase to earth computer port LTW335 only 2 6 Lid open closure 1 Open lid by lifting up front panel tab 1 2 Foldaway underneath instrument 2 amp 3 and push into retaining slot 4 3 Preparations for use The instrument is supplied with batteries already fitted However when fitting replacement batteries refer to section 10 2 WARNING Never use the instrument with the battery cover removed Incorrect battery cell polarity can cause electrolyte leakage resulting in damage to the instrument Always fit a complete new set of batteries never mix old and new cells Check that the Battery level indicator displays a full charge before using the instrument A low battery charge may indicate a reversed cell Note Battery cells should not be left in an instrument which may remain unused for an extended period of time 3 1 Preliminary test lead check Before each use of the instrument visually inspect the test leads prods and crocodile clips to confirm that their condition is good with no damaged or broken insulation 3 2 Ingress of moisture If it is suspected that moisture has entered the instrument such as extended periods of cold and wet conditions the instrument should be dried out prior to use This can be accelerated by removing the battery cover to assist drying 4 General operating instructions 4 1 Backlight operation P
2. is displayed at the end ofa test the test should be repeated or the test mode changed to mode 2 refer to section 8 SETUP procedure Mode 2 AUTO Default setting In Mode 2 the LTW loop tester can detect noise on an electrical supply that could affect the measurement accuracy and automatically extend the loop test from 10 seconds up to 20 seconds as necessary The Lt symbol is displayed to indicate an extended test is running If the noise symbol 40 is displayed at the end of the extended test it is recommended the test be repeated The instrument is shipped with mode 2 selected To change the test modes refer to the SETUP procedure section 8 5 1 1 2 Symbols used during a normal loop test TEST The TEST symbol is displayed for the duration of an active loop test If electrical noise is detected during the loop test that could affect the accuracy of the answer the following additional symbols may appear If a low level of electrical noise is detected in mode 2 the it will be displayed to the right of the symbol The test time will be extended up to a further 10 seconds to improve the accuracy of the test results This only applies if the tester is running in mode 2 see section 5 2 1 12 Ifa high level of electrical noise is detected the symbol dl will be displayed This indicates that excessive noise was detected during the test If this remains displayed at the end of the test it is rec
3. To remove the rear cover remove the retaining screw from the rear of the battery cover and lift the cover off 4 Remove the dead batteries and refit new batteries observing the correct polarity as marked on the battery compartment 5 Replace the cover and retaining screw 6 Switch on instrument and check battery indicator WARNING Incorrect battery polarity may prevent instrument operation or can cause electrolyte leakage or damage the instrument If the battery condition indicator does not show a full charge a cell may be reversed Note Batteries should not be left in an instrument which may remain unused for an extended period 10 3 Fuse Blown indication Tt If the fuse has blown after contact with a live supply the fuse blown symbol and the UnS message will be displayed and the instrument will start beeping These symbols and a periodic beeping will continue until the instrument is switched off This will only happen if a serious internal fault has occurred Please contact Megger Limited at the contact address at the end of this guide or call Technical support on 44 0 1304 502 102 for further assistance The fuse must not be replaced until advice has been received from Megger Limited 11 Auto power down To extend battery life the instrument will automatically switch off two minutes after the last operation It can be switched off by selecting OFF with the lower range switch or switched back on again
4. Green lead connected to the Neutral conductor This test can also be performed using the mains socket test lead using the RED and BLUE connectors 5 3 3 High current Phase to Phase loop test Repeat test 5 3 1 with the Green lead connected to another phase conductor 14 NOTE Both the High current and No Trip loop tests will operate Phase to Phase 5 4 High resolution loop test High Resolut LTW425 only The High Resolut Loop test performs a 2 wire high current loop test providing a loop test result to one milliohm 0 001 Q resolution This test is designed for non RCD protected circuits A limited number of these tests can be done before the instrument will indicate over temperature display the hot warning and inhibit further tests In which case leave the instrument to cool down for a few minutes 5 4 1 All the high current tests in section 5 3 can be performed with the instrument set to High Resolut Note In order to protect instrument from overheating it is necessary to introduce pause time during testing thus extending the High Resolut test to 15 seconds for measurements on supplies of less than 260 V a c and 30 seconds for measurements on supplies above 260 V a c 5 5 Prospective Fault Current display PFC NOTES The PSCC of a circuit is the largest Prospective Fault Current PFC In a single phase system this would be the larger of the earth loop PFC and the neutral loop PSCC In a multi phase system phase phas
5. V a c supply EN61557 operational range 0 30 Q to 1000 Q High resolution loop test LTW425 only Source voltage 50 V to 440 V 50Hz Display range 0 001 Q to 2000 Q Accuracy 5 0 01 Q Nominal test current 4 A at nominal 230 V supply EN61557 operational range 0 300 Q to 1000 Q Prospective Fault Current PFC Prospective fault current Measured voltage Loop resistance Maximum range 40 kA Accuracy is derived from loop test and voltage measurement Environmental Temperature and humidity Operating Range 10 C to 60 C Operating Humidity 90 R H non condensing at 40 C max Storage Range 25 C to 70 C Maximum altitude 2000m to full safety specification Dust and water ingress IP54 Safety Designed to IEC61010 1 ed2 2001 02 and IEC 61557 part3 1997 25 Designed for 300 V to Earth Category IV With Phase to Phase voltages to 440 V Fuse protected to 600 V rms a c A warning will be shown if applied voltage exceeds 440 V Damage will occur if applied voltage exceeds 500 V rms IEC61557 Complies with the following parts of EN61557 Electrical safety in low voltage systems up to 1000V ac and 1500V dc Equipment for testing measuring or monitoring of protective measures Part1 General Requirements Part3 Loop resistance E M C In accordance with IEC61326 including amendment No 1 Power supply Battery 8 x 1 5 V cells IEC LR6 type AA alkaline Rechargeable 8 x 1 2V NiMH cells Battery life 2000
6. a reminder to warn of there is a loop resistance offset selected To remove loop test Offset 16 Select SETUP on the instrument lower range knob 17 Press the button until the display shows Null 18 Press the TEST button to select the function 19 Press the gt button until the display shows 0 00 Button can be held down to automatically count up 20 Press the TEST button to store the offset 21 The Or symbol will now disappear 8 3 Backlight brightness adjust The backlight has four levels e OFF Disabled e Low Default e Medium e High To adjust the backlight brightness or disable backlight completely 1 Select SETUP on the instrument lower range knob LS 2 Press the backlight button A repeatedly to achieve the desired setting Exit SETUP mode by turning the lower range knob to any other position 21 9 Warning and status messages 9 1 Loop test inhibit or premature termination of a loop test A loop test may stop or even be prevented from starting if there is a connection problem with the test leads or instrument fuse an earth problem on the circuit being tested or a supply voltage or frequency out of range Test inhibit If an out of range voltage or frequency exists on the circuit under test testing will be automatically inhibited and the corresponding information will be displayed The following Exceptions and Warning screens may be displayed du
7. available using the 2 wire lead set 5 2 3 1 Phase to earth loop test 1 Select the No Trip test range on the lower range knob and Z on the upper range knob where present 2 Connect the RED and GREEN test leads to the instrument 3 Connect the RED test lead to the Phase conductor and connect the GREEN test lead to the Earth conductor 4 The loop test will automatically start and the TEST symbol will appear and remain on for the duration of the test 5 After a test period of 10 seconds the measured loop value is displayed 6 To repeat the loop test press the TEST key The symbols 40 and it may appear during the test Refer to section 5 1 1 2 Symbols for an explanation of their meaning 5 2 3 2 Phase to Neutral and Phase to Phase loop testing Both Phase to Neutral and Phase to Phase testing can be made using the No Trip test as described above for the Phase to earth test However a High current test will not trip RCDs when making either a P N or P P test and it is recommended that a High current test is used for both these measurements 5 2 4 Earth bonded metalwork testing Repeat the test 5 2 3 1 Phase to Earth test above but with the GREEN lead connected to the exposed metalwork providing the earth return path 5 3 High current loop test High Current The High Current loop test performs a 2 wire high current test at around 4 A ona 230 V supply providing a very stable and fast loop test WARNING This test
8. by pressing the TEST button To extend the auto switch off time to 20 minutes refer to section 8 SETUP options 12 Preventive maintenance Clean only with a damp cloth Do not use any alcohol based cleaning fluids as they may leave a residue Isopropyl alcohol or similar solvent cleaner should only be used to clean the 4mm probe sockets on the instrument on a regular basis 24 13 Technical specification 13 1 General specification Only values with tolerances or limits are guaranteed data Values without tolerances are for information only Accuracy All accuracy statements are based on Ambient temperature 29022 Nominal source voltage 230 V a c 1 Voltage measurement a c only 50 V to 440 V Accuracy 2 1 V Frequency measurement Range 25 Hz to 99 99 Hz Accuracy 0 1 Hz Loop testing NO TRIP loop and high current loop test LTW315 Source voltage 100 V to 280 V 50 Hz Display range 0 01 Q to 2000 Q Accuracy 5 0 03 Q 230 V a c 10 0 03 Q 100 V a c and 280 V a c NO TRIP loop and high current loop test LTW325 LTW335 and LTW425 Source voltage 50 V to 440 V 50 Hz Display range 0 01 Q to 2000 Q Accuracy 5 0 03 Q 230 V a c 10 0 03 Q 100 V a c and 300 V a c LTW325 and LTW425 10 0 02 Q LTW425 15 0 03 Q 50 V a c LTW325 LTW335 and LTW425 Nominal test current No Trip loop test 15 mA at nominal 230 V a c supply High current loop test 4 A at nominal 230
9. consecutive tests Mechanical Weight 1000g 10 excluding test leads Dimensions 203 x 148 x 78 mm 14 Accessories and equipment 14 1 Supplied with appropriate instruments Optional accessories Alternatively specific units will be supplied with the following alternative to ii above 1 x Mains plug test lead AS NZS 3112 1 x Mains plug test lead CEE 7 7 Patents The loop testing technologies used in these instruments are subject to the following patent applications UK Patent no 0518089 9 European Patent no 06119110 2 US and Canadian patent application 26 15 Repair and Warranty The instrument contains static sensitive devices and care must be taken in handling the printed circuit board If an instrument s protection has been impaired it should not be used but send for repair by suitably trained and qualified personnel The protection is likely to be impaired if for example it shows visible damage fails to perform the intended measurements has been subjected to prolonged storage under unfavourable conditions or has been subjected to severe transport stresses NEW INSTRUMENTS ARE GUARANTEED FOR 3 YEARS FROM THE DATE OF PURCHASE BY THE USER NOTE Any unauthorized prior repair or adjustment will automatically invalidate the Warranty CALIBRATION REPAIR AND SPARE PARTS For service requirements for Megger instruments contact Megger Limited or Megger Archcliffe Road Valley Forge Corporate Centre Dover 2
10. contact with circuit without the need to press ON OFF the TEST button Restores factory settings 8 1 Setup option selection 1 Select SETUP on the lower range knob Instrument firmware revision will be displayed briefly Wait for the instrument to display SEt 2 Press the key to cycle through the SETUP options until the required setup option is displayed Press TEST to select the function 4 Press the key to cycle through the options available for that function Once the desired option is displayed press TEST to store setting The display will show Ok and then return to the function heading To select another function repeat from step 2 5 To go back to main menu SEt press PFC button 6 To exit SETUP mode turn the lower range knob to any other position 8 2 Fused or long test lead length The test lead resistances of the supplied test leads are already calibrated into the instrument However should the optional fused leads or a longer lead set be used the additional resistance can be set in the instrument so as not to affect the loop test result To establish additional resistance of new lead set NOTE The high current loop test should be used for this adjustment to ensure accurate measurements Ensure the top range knob is set to Z does not apply to the LTW315 Select the High Current test range on the instrument lower range knob Connect the standard supplied RED and GREEN
11. is designed for non RCD protected circuits Due to the high currents used the instrument adds a brief pause between tests to prevent overheating This is indicated by the symbol and appears for a nominal 5 seconds between tests for voltages lt 260 V and 10 seconds for voltages above 260 V 5 3 1 High current Phase to Earth loop test 1 Select the High Current test range on the lower range knob and Z on the upper range knob where present 7 Connect the RED and GREEN test leads to the instrument 8 Connect the RED test lead to the Phase conductor 9 Connect the GREEN test lead to Earth conductor This test can also be performed using the mains socket test lead using the RED and GREEN connectors 10 The loop test will automatically start and the TEST symbol will appear and remain on for the duration of the test 11 The measured loop value is displayed Note The AUTO START function will not operate if the instrument is connected to a live supply BEFORE the range knob is moved to High Current This is to prevent tripping of RCDs by accidentally selecting the High Current test instead of No Trip test with the leads connected to the supply In which case pressing the TEST button will start a test Subsequent connection of test leads will run the AUTO START test AUTO START can be disabled in the SETUP procedure as described in section 8 5 3 2 High current Phase to Neutral loop test Repeat test 5 3 1 with the
12. is recommended that tests are repeated and the results verified If measurements are far apart results should be considered abnormal Errors can be reduced by Use the two wire lead set with prods and a firm connection to clean conductors Making several tests and taking the average Ensure that potential sources of noise in the installation are isolated switched off eg automatically switched loads or motor controllers n Ensuring that the instrument is calibrated Ensure the 4mm test probe sockets on the instrument are clean and free of grease and dirt by using a cotton bud dipped in Isopropyl alcohol or similar solvent cleaner Further errors can be caused by proximity to transformers Testing in the close proximity of a transformer can cause errors in measurement because of the worsening of the power factor caused by the large proportion of reactance in the measurement Worst case operating error calculated for Non Trip measurement mode in accordance with IEC 61557 3 1997 influence quantity operating range o ea Designation Code Error influence quantity operating range Position Reference position 90 _ EL 10 E R Supply voltage Battery voltage at 8 V to 13 2 V E2 o 0 0042 Temperature 0 C and 40 C using 10Q loop measured at E3 0 023 230V in Non Trip mode 1 2 Phase angle At a phase angle 0 to 18 0 0489 System frequency Frequency of 49 5 Hz to 50 5 Hz 0 024 System voltage Voltage of 195 5 V
13. lower than stored Zref Zref measurement required before an R1 R2 measurement can be made n me Supply frequency out of range Display switches between 4 900 rd 4 ub frequency and voltage Display shows lt 49 00Hz or gt 51 00Hz s PO lo ie n 5 J Severe noise on supply Re test 10 Replacing batteries and fuses Batteries Battery type 8 x LR6 AA 1 5 V Alkaline or 8 x 1 2 V NiMH 10 1 Low battery warning symbol The battery condition is continuously displayed by the following symbols 100 IMIN If the battery symbol drops to two bars the batteries will need replacing 75 JH 0 To replace the batteries follow the procedure in 10 2 below Please dispose of exhausted batteries carefully 50 Ii I 25 J 0 ba oe bAt In addition the main display warns that batteries need replacing No further testing is possible until batteries have been replaced Note NiMH rechargeable batteries show a lower charge than Alkaline batteries and may not give much warning before becoming exhausted 23 10 2 Procedure to replace batteries WARNING Do not switch the instrument on with the battery cover removed The rear cover must not be opened if the test leads are connected 1 Switch off the instrument and disconnect the instrument from any electrical circuits 2 To avoid the possibility of electric shock do not press the test button or touch the fuse when changing batteries 3
14. sending the instrument carriage paid to Megger 5 You may track the progress of your return on line by accessing the Service Support facilities at www megger com sd Approved Service Centres A list of Approved Service Centres may be obtained from the UK address shown If outside UK USA please consult your distributor for the most convenient Service Organisation DE Megger Limited Archcliffe Road Dover Kent CT17 9EN England T 44 0 1 304 502101 F 44 0 1 304 207342 E uksales megger com Megger 4271 Bronze Way Dallas Texas 75237 1019 USA T 1 800 723 2861 USA ONLY T 1 214 333 3201 F 1 214 331 7399 E ussales megger com Megger Z A Du Buisson de la Couldre 23 rue Eug ne Henaff 78190 TRAPPES France T 33 0 1 30 16 08 90 F 33 0 1 34 61 23 77 E infos megger com Megger Pty Limited Unit 26 9 Hudson Avenue Castle Hill Sydney NSW 2125 Australia T 61 0 2 9659 2005 F 61 0 2 9659 2201 E ausales megger com Megger Limited 110 Milner Avenue Unit 1 Scarborough Ontario M1S 3R2 Canada T 1416 298 9688 Canada only T 1416 298 6770 F 1416 298 0848 E casales megger com Megger products are distributed in 146 countries worldwide This instrument is manufactured in the United Kingdom Megger The company reserves the right to change the specification or design without prior notice Megger is a registered trademark Part No LTW300 Series UG en V03 0507 www megger com 28
15. test leads to the instrument Connect the RED test lead to the Phase conductor Connect the GREEN test lead to the Earth conductor or to the Neutral conductor if the circuit is RCD protected Press the TEST key The measured loop value is displayed 7 Note down the loop test value 8 Repeat the same loop test with the new test leads and note down the value This value should be higher than the first test result 9 Subtract the first test result from the second test result to obtain the additional loop resistance created by the new lead set Er on 20 If the result is negative the second lead set resistance is less that the standard supplied lead set and should not be used for loop testing on this instrument If the result is greater than 0 99 Q the instrument will not be able to take fully into account of the extra lead resistance In this instance do not use the lead set or manually subtract the difference from every subsequent measurement To enter the additional lead resistance to correct the instrument measurements 10 Select SETUP on the instrument lower range knob 11 Press the gt button until the display shows Null 12 Press the TEST button to select the function 13 Press the button until the display shows the additional resistance required 14 Press the TEST button to store the offset The display will show Ok to confirm setting has been saved 15 The display will show the O as
16. to 253 V 0 00038 es B 2002 YB Operating error B Al LISJE E E Eg E E 5 7 maxZ LTW325 LTW335 and LTW425 The maximum loop impedance value of any final ring circuit or any series of loop measurements can be derived by using the MaxZ function 1 Select the MaxZ test range on the top range knob 2 Make a loop test measurement as described in section 5 above The instrument will display and hold the loop resistance value 3 For subsequent loop tests the instrument will display the new loop value If this is higher than the previous result it will be held on the display Lower values will only be displayed for 2 seconds prior to reverting to the higher result 5 8 Deriving R R LTW325 LTW335 LTW425 Automatic Derivation of an R1 R2 value The LTW325 LTW335 and LTW425 are able to derive the R1 R2 circuit impedance from tests made on a live installation It is not possible to isolate R1 or R2 separately 16 Application note for Zref and R1 R2 measurement On initial verification ofa new electrical installation the value for R1 R2 should be obtained by continuity testing methods dead testing as per BS 7671 2001 or other international standards For periodic inspection reports PIR where it is not possible to isolate the supply the user should first verify the Circuit Protective Conductor standard practice prior to using the Zref and R1 R2 function on the instrument Prior to measuri
17. 621 Van Buren Avenue Kent CT17 9EN Norristown PA 19403 England U S A Tel 44 0 1304 502 243 Tel 1 610 676 8579 Fax 44 0 1304 207342 Fax 1 610 676 8625 Megger operate fully traceable calibration and repair facilities ensuring your instrument continues to provide the high standard of performance and workmanship you expect These facilities are complemented by a worldwide network of approved repair and calibration companies which offer excellent in service care for your Megger products Returning your product to Megger UK and USA service centres 1 When an instrument requires recalibration or in the event of a repair being necessary a Returns Authorisation RA number must first be obtained from one of the addresses shown You will be asked to provide the following information to enable the Service Department to prepare in advance for receipt of your instrument and to provide the best possible service to you Model e g LTW300 Serial number e g 61110357050305 1234 Reason for return e g calibration required or repair Details of the fault if the instrument is to be repaired 2 Make anote of the RA number A returns label can be emailed or faxed to you if you wish Pack the instrument carefully with plenty of padding but no pressure on window or glass Ensure the returns label is attached or that the RA number is clearly marked on the outside of the package and on any correspondence before
18. Megger LTW300 Series Earth Loop testers User Guide ZN Safety warnings E Safety Warnings and Precautions must be read and understood before the instrument is used They must be observed during use E The earth loop impedance test creates a temporary low resistance path between live and earth for the duration of the test This is particularly hazardous with both an instrument fault and an installation fault Working practice and hazard avoidance must take care of this risk Continuity of protective conductors and earthed equipotential bonding of new or modified installations must be verified before carrying out an earth fault loop impedance test Circuit connections and exposed metalwork of an installation or equipment under test must not be touched Do not leave the instrument connected to the mains supply when not in use Do not leave the instrument connected to the mains supply when performing data download to a PC Ensure that hands remain behind guards of probes clips when testing The instrument should not be used if any part of it is damaged The battery cover must be in place whilst conducting tests Test leads probes and crocodile clips must be in good order clean and with no broken or cracked insulation On test leads fitted with a outlet plug and flying leads never connect test probes clips pins or other objects to the 3 lead plugs because of the danger of electrocution These leads should only be used by a suitably trai
19. The display will show the test record to be deleted ie d034 2 Press the OK button The last test result will be will be deleted 3 Repeat step 2 to delete another record To delete all test data WARNING This operation is not reversible All data will be deleted 1 Set the lower range knob to DEL The display will show the test record to be deleted 2 Press the UP or DOWN key The display will show dALL and the warning symbol A 3 Press the OK button All the test results will be will be deleted The display will show d to indicate all records are deleted 19 8 SETUP menu The SETUP mode allows the following functions to be configured option setting AOFF AUTO OFF time The automatic switch off time of the instrument can be extended 2min 20min 2min buZZ Buzzer ON OFF gre anten len tet fos tVI Touch Voltage limit This is the voltage the earth wiring or CPC can be allowed to rise 25V 50V to whilst performing a loop test This is set to 50 V but can be adjusted to 25 V where necessary Null Lead null Allows additional test lead resistance of longer or fused test leads to be nulled from the test results See 8 2 below tESt No trip Test mode The instrument can be set to perform a 10 second loop test or 10s Auto Auto an automatic loop test that extends the test time up to 20 seconds if it detects any supply changes that could affect test results AuSt Automatically starts loop test Starts loop test on
20. e loops also need to be considered and are measured in the same way as single phase supplies PFC measurement accuracy An accurate PFC measurement requires an accurate measurement of the loop resistance The difference of a few digits in the loop resistance measured will have a large effect on the PFC displayed Calculation of PFC and PSCC is based on the measured voltage divided by the measured loop resistance in ohms Measured Voltage _ PFC Loop resistance The displayed value of PFC is calculated from the test results of voltage and resistance BEFORE they have been rounded for display Consequently the displayed PFC may not exactly correspond to the result of manual calculation using displayed results of voltage and resistance 5 5 1 PFC measurement 1 On completion of any loop test press the PFC key 2 The prospective fault current is displayed in Amps 3 Press PFC key again to return to loop impedance result 15 5 6 Possible sources of error The displayed reading depends on a measurement of the supply voltage and therefore noise or transients caused by other equipment during the test could cause an error in the reading One way to check for these is to do two tests and look for any difference in value The instrument may detect some sources of noise and warn the user Test results may be adversely affected by supply voltage fluctuations voltage glitches spikes or electrical noise during a measurement It
21. ned and competent person E Some national safety authorities recommend the use of fused leads for voltage measurement on high energy systems If loop tests are made it may cause the fuse to rupture and so they must be used with caution on voltage testing NOTE THE INSTRUMENTS MUST ONLY BE USED BY SUITABLY TRAINED AND COMPETENT PERSONS Users of this equipment and or their employers are reminded that Health and Safety Legislation requires them to carry out valid risk assessments of all electrical work so as to identify potential sources of electrical danger and risk of electrical injury such as inadvertent short circuits Symbols used on the instrument A Caution refer to accompanying notes D Equipment protected throughout by Double Insulation Class ID C Equipment complies with relevant EU Directives NIJ Equipment complies with Australian and New Zealand C Tick requirements Contents Introduction General introduction Unpacking the carton LCD display Top panels Additional controls on the LTW335 Keypad controls Range knob controls Connection panel Lid open closure Preparations for use Preliminary test lead Ingress moisture General operating instructions Backlight operation Test leads Test lead connection Loop testing Description of test methods No trip test all instruments Symbols used during a normal loop test High current test all instruments High resolution test LTW425 only Performing a loop test Non t
22. ng Zref all main equipotential bonding must be in place Note Measurements made on live installations by this method may be lower than the Ze R1 R2 from those obtained by continuity testing methods due the existence of parallel earth return paths from extraneous conductive parts To make use of the R1 R2 test feature the reference distribution board Ze or Zdb result must be stored in the instrument s memory Zref prior to measuring R R 5 8 1 Measuring Zref 1 Switch the top range knob to Zref The display will show the Zref symbol to indicate a Zref test mode is selected 2 Select any loop test range as appropriate 3 Connect the instrument to the circuit under test as described in section 5 2 5 3 or 5 4 as required 4 Press the TEST button to perform a loop test The test result is displayed and stored internally as Zref 5 8 2 Measuring R1 R2 5 Switch the top range knob to the R1 R2 range The display will show the R1 R2 symbol to indicate an R1 R2 test mode is selected 6 All subsequent loop test measurements will have the Zref resistance subtracted To view the stored value of Zref press the PFC key press the PFC again to return to the R1 R2 value 8 Ifmeasured value of R1 R2 is less than zero the display will show the measured value of R1 R2 for 2 seconds then the error message ertF will be displayed to indicate such error In which case repeat the R1 R2 measurement If the error pe
23. ommended the test is repeated 5 1 1 3 High current test All instruments Performs a very fast loop test at a nominal 4A test current Description A resistive load 59 Q is used to measure voltage drop and calculate the loop resistance If the loop contains inductance the inductive reactance will be largely ignored The loading current duration varies from 10 milliseconds to 640 milliseconds depending on the test condition When testing in close proximity to the sourcing transformer a system phase angle of 18 will cause an additional error of 5 5 1 1 4 High resolution test LTW425 only Performs a sequence of many high current loop tests to calculate a loop test result to three decimal places Description Alternate voltage measurements on loaded and unloaded half cycles using a load resistor of approximately 59 Q as with the High Current test The number of test cycles will be adjusted to obtain the optimum performance When testing in close proximity to the sourcing transformer a system phase angle of 18 will cause an additional error of 5 ALL TESTS WILL OPERATE PHASE TO EARTH PHASE TO NEUTRAL AND PHASE TO PHASE NOTE THE LTW315 IS NOT RATED FOR PHASE TO PHASE MEASUREMENTS ON 240 VOLTS TO EARTH SYSTEMS 5 2 Performing a loop test Note Factory settings for the instrument are AUTO START enabled Mode 2 extended testing enabled 5 2 1 Non tripping loop test No Trip The No Trip range is a 0 01 Q resol
24. only PC software CD LTW335 only Warning sheet 5172 238 2 2 LCD display Fuse Blown Wait Refer to Temperature warning User manual Test Lead NULLED Indicator RCD Trip Indicator k ON rn Battery status gt K iii Measured results Ranges m r e Touch k AV voltage ee py eek upply L Ov Zret RNA TEST AY AG noise warning Zref function selected R1 R2 Function Loop test Loop test extended required before R1 R2 can selected active Mode 2 operation be measured 2 3 Top panels Test lead connections See section 2 5 Loop test function all except LTW315 Z MaxZ LCD Display RI R2 Zref Setup function select Neck strap slots Test button Range selector NO TRIP High Current HIGH Res LTW425 Volts Frequency Setup PFC display Backlight Front panel cover key On Off folded under instrument 2 4 Additional controls on the LTW335 storage and downloading instrument 2 4 1 Keypad controls ESC UP DOWN arrows OK Aborts a result save Scrolls through circuit and Confirms a test result delete process distribution board numbers request NEXT Selects test type Job Distribution board Circuit Phase etc STORE Stores last test result LAST As next 2 4 2 Range knob controls cy Test result delete Last result Stored data recall download 2 5 Connection panel Single or 3 Phase Earth Neutral or 2 phase connection connection
25. priate sockets on the rear of the instrument marked LO L2 and L1 Standard test probes and crocodile clips and mains socket test lead are supplied for connection to the circuit under test System Diagram Where to use each test AS sutra Hegh rent es nje ghae loop Pune tn Mhae voup tot Phase to Larth op tes i LI T Ei TE Eee Vil ees 4 3 o N P High Current High Current or High Current No Trip 11 5 Loop testing Different loop testing options are available depending on the instrument used as below Instrum NO TRIP High MaxZ HIGH Result storage 50V 100 V ent Current R1 R2 Resolution and download 440V 280 V 5 1 Description of test methods 5 1 1 No trip test All instruments Designed not to trip circuits protected by an RCD 230mA Description A resistive load 15 KQ switched and rectified at Mains Frequency 6 in order to produce a test current at the same frequency The voltage produced by this test current is then used to calculate the loop resistance If the loop contains inductance the inductive reactance will be largely ignored When testing in close proximity to the sourcing transformer a system phase angle of 18 will cause an additional error of 5 5 1 1 1 No trip test modes Two test modes are available in the No Trip loop test mode providing Mode 1 10s Mode 1 performs a 10 second loop test only At the end of the test a result is displayed If the noise symbol dl
26. ressing the BACKLIGHT A button will toggle the backlight on and off The backlight will automatically switch on at the start and end of a test It will switch off 5 seconds after the end of the test Backlight brightness can be adjusted whilst in SETUP mode see SETUP section 8 4 2 Test leads All test leads form part of the measuring circuit of the instrument and must not be modified or changed in any way or be used with any other electrical instrument or appliance The mains plug test lead supplied with the Megger Tester is a test lead that forms part of the measuring circuit of the instrument The overall length of this lead should not be altered However if the power cord plug is not suitable for your type of socket outlets do not use an adapter You may change the plug once only by cutting the cord as close to the plug as possible and fitting a suitable plug The colour code of the cord is Earth Ground Yellow Green Neutral Blue Phase Line Brown Non standard test leads Where fused or longer length leads may be used the lead resistance will be higher than the value to which the instrument is calibrated To add additional offset in the loop measurement refer to section 8 instrument setup procedure 10 WARNING A plug severed from the power cord must be destroyed as a plug with bare conductors is hazardous in a live socket outlet 4 3 Test lead connection The supplied test leads should be connected to the appro
27. ring testing Ready to test No trip loop test No supply voltage connected Ready to test using High Current loop test No supply voltage connected TEST IN PROGRESS messages era Supply interrupted or lost during test eg test probe slipped This will C disappear after 2 seconds and the tester will attempt to repeat the test gt INNN Touch voltage limited measurement to 1000 Check earth bonding of I uuu installation before further testing lt 1 Supply voltage missing or low 1 Hot warning Thermometer symbol 5 flashes Allow instrument to cool U ba down but testing can continue if necessary h Instrument overheated Allow to cool down 0 1 n Noise symbol A displayed at end of test indicates result may have been U adversely affected by electrical noise during test Test should be repeated Instrument needs calibration Further testing is possible but not recommended unc H ab UNSERVICEABLE Instrument needs to be returned for repair U Circuit voltage may also be displayed Nr UNSERVICEABLE Fuse failed un Circuit voltage may also be displayed 22 Sill n t Instrument malfunction If repeated follow returns procedure U Any E followed by a number ie E001 E002 Faulty stuck key or switch position sINNN Loop test result out of display range g UUU n Over voltage warning 4 H For LTW315 the warning will be lt 280 V g r E F No Zref value stored or test result
28. ripping loop test NO TRIP No trip testing using the mains socket test lead Phase to Earth loop test Phase to Neutral loop test No trip loop testing using the RED GREEN test lead Phase to Earth loop test Phase to Neutral and Phase to Phase loop testing Earth bonded metalwork testing High current loop test High current Phase to Neutral loop test High current Phase to Phase loop test High resolution loop test LTW425 only Prospective fault current display PFC PFC measurement Possible source of error MaxZ LTW325 LTW335 and LTW425 Diriving R1 R2 LTW325 LTW335 and LTW425 Measuring Zref Voltage and frequency measurement Phase to Earth and Phase to Neutral voltage and frequency measurement Phase to Phase voltage and frequency measurement Saving and downloading test results LTW335 only Storing LOOP test results To store a result To store subsequent result To recall test result Downloading results to a PC Deleting test results SETUP menu Setup option selection Fused or long test lead length Backlight brightness adjust Warning and status messages Loop test inhibit or premature termination of a loop test Replacing batteries and fuses Low battery warning symbol Procedure to replace batteries Fuse blown indicator Auto power down Preventative maintenance Technical specification Accessories Repair and Warranty 99 DOW WON NWN A 1 Introduction Thank you for purchasing the Megger Earth Loop impedance tester For your own safe
29. rsists repeat with a new Zref measurement followed by R1 R2 Ifa Zref measurement was not made prior to an R1 R2 test an R1 R2 test will not be performed and the warning ort will be displayed for 2 seconds 6 Voltage and frequency measurement WARNING The instrument must not be used on CATII CATIII or CATIV systems with voltages greater than 300V phase to earth and 440V Phase to Phase 6 1 Phase to Earth and Phase to Neutral voltage and frequency measurement To measure the voltage of the electrical supply using the mains socket test lead Set the instrument to the V Hz range Connect the RED plug of the mains socket test lead to the instrument Connect the GREEN plug of the mains socket test lead to the instrument Insert the plug into the mains outlet socket The instrument will display the voltage and the frequency roy A To measure the Phase Neutral voltage connect the RED and BLUE plug of the mains socket test lead to the instrument To measure the voltage of the electrical supply using the RED GREEN test leads 1 Set the instrument to the V Hz range 2 Connect the GREEN test lead to the Protective Earth PE and the RED test lead to the phase to be measured 3 The instrument will display the voltage and the frequency 17 4 Alternatively the instrument can be connected Phase to Neutral to measure the Phase Neutral voltage 6 2 Phase to Phase voltage and frequency measurement 1 Set the in
30. strument to the V Hz range 2 Connect the GREEN test lead to one phase and the RED test lead to another phase 3 The instrument will display the voltage and the frequency 7 Saving and downloading test results LTW335 only 7 1 Storing LOOP test results Test results storage has the following structure within the instrument Jb 00 Jb 01 99 Job number db 01 db 02 db 03 99 Distribution board Number Ct 01 Ct 02 Ct 03 99 Circuit number Ln LL Ln LE Ln LN Ln NE Line connection Phil Phi 2 Ph 3 Phase IS VF tS nt tS tr Test type ROOO to R999 Record number Definitions TS OO JD OM asset Job number acts as work folders Sets of results can be saved to a particular job number and easily separated when downloaded COOL a 0 Z neee Distribution board number Results can be assigned a specific distribution board number CROT CEO 2 ar ats tied osetia eden eee Circuit reference Results can be assigned a specific circuit reference number Ln LL Ln LE Line connection Test lead connections ie Live to Earth Ln LE Ph 1 Ph 2 Ph 3 Phase number Each test can be stored under a particular phase P1 P2 or P3 SVEIS DGIS U vie Test type Each test result is automatically assigned the test type VF represents Voltage Frequency test nt is no trip test and tr is high current test R000 RO01Unique Record number Each test result is assigned a unique record number from 0 to 999 logged automa
31. tically This cannot be changed by the user 7 2 To store a result 1 Make aZ MaxZ Zref or R1 R2 loop measurement as described in Section 5 2 Press STORE to enter the storage menu 3 Select job reference number using the UP DOWN keys then press NEXT Hold the key down to scroll quickly through the numbers Select distribution board number db 01 db 02 etc using UP DOWN keys then press NEXT Select circuit number Ct 01 Ct 02 etc using the UP DOWN keys then press NEXT Select Ln LL Ln LE Ln LN Ln NE by pressing the UP DOWN keys then press NEXT Select the Phase using the UP DOWN keys then press NEXT The screen will display a unique record number which is attached to that particular test 8 Press OK to save the result 9 Press ESC to skip at any point SORT ee 7 3 To store a subsequent result To save the next test under the same job number distribution board etc 1 Make another measurement as described earlier and press STORE 2 The last Job number will be displayed Press OK Note To change any setting before saving a result scroll down through the result using the NEXT LAST keys Change the distribution board circuit number etc using the UP DOWN keys and press OK 7 4 To recall test result 1 Set the lower range knob to RECALL 2 The last unique record number is displayed 3 Use the UP DOWN keys to select the test record to recall 4 Use the LAST or NEXT keys to scroll through job number distribu
32. tion board circuit number etc associated with the test result 5 Press OK and the test result will be displayed 18 6 Each recalled result will have two values Use the LAST and NEXT buttons to switch between the two values In the case of Voltage Frequency tests one result will be voltage in volts and the other result will be the frequency in Hz In the case of Z MaxZ and Zref tests one result will be the impedance in ohms and the other result will be the circuit voltage allowing PFC to be calculated In the case of the R1 R2 test one result will be Zref and the other will be R1 R2 7 Press ESC to go back to the record number Repeat from step 3 to recall other test records 7 5 Downloading results to a PC 1 Run Megger PowerSuite Professional or Megger Download Manager on the PC 2 Select the appropriate downloading instrument from the list Ensure the LTW300 driver is selected ie MIT LTW RCDT and NOT MIT LT RCDT Select Download from the software tool bar Connect the tester to the PC using the USB download lead Set the lower range knob to SEND The instrument will automatically download its contents to the PC A bar graph shows the status of the download ve WARNING On completion of the download disconnect the USB lead before commencing further testing 7 6 Deleting test results To delete the latest test result WARNING This operation is not reversible 1 Set the lower range knob to DEL
33. ty and to get the maximum benefit from your instrument please ensure that you read and understand the following safety warnings and instructions before attempting to use the instruments This user guide describes the operation and functions of the following LTW300 series of loop impedance testers LTW315 LTW325 LTW335 LTW425 These instruments are designed and manufactured by Megger Limited Archcliffe Road Dover Kent CT17 9EN England Megger reserves the right to change the specification of these instruments at any time without prior notice 2 General description The LTW300 series loop testers are designed for the measurement of loop resistance Impedance of fixed electrical installations on single and 3 phase systems 2 1 Unpacking the carton Unpack the carton contents carefully There are important documents that you should keep for future reference Please complete the pre paid warranty card and return it to Megger as soon as possible to help us reduce any delays in supporting you should the need arise Carton contents for the LTW315 LTW325 LTW335 and LTW425 X e oe oe OO One a oe KK KK KM KK KM OM LTW series loop tester 2 wire test lead with prods with clips Red Green Mains lead set UK Schuko or Australian depending on instrument supplied AA LRO batteries fitted in instrument Warranty card Certificate of test Calibration certificate Owners CD manual Hard carry case USB cable LTW335
34. ution low test current earth loop resistance measurement 5 2 2 No trip testing using the mains socket test lead The instrument is supplied with AUTO START enabled and in Test Mode 2 which will automatically extend a test if noise is detected 5 2 2 1 Phase to earth loop test 1 Select the No Trip test range on the lower range knob and Z on the upper range knob where present 2 Connect the RED plug of the mains socket test lead to the instrument 3 Connect the GREEN plug of the mains socket test lead to the instrument 4 Insert the plug into the mains outlet socket 5 Ensure the supply voltage is displayed The loop test will automatically start and the TEST symbol will appear and remain on for the duration of the test 6 After a test period of 10 seconds the measured loop value is displayed and the TEST symbol will disappear To repeat the loop test press the TEST key The symbols Ah and it may appear during the test Refer to section 5 1 1 2 Symbols for an explanation of their meaning 5 2 2 2 Phase to neutral loop test Phase to Neutral testing can be made using the No Trip test as described above for the Phase to earth test However a High Current test will not trip RCDs when making a P N test and it is recommended that a High Current test is used for this measurement 13 5 2 3 No trip loop testing using the RED GREEN test leads The No Trip loop test can be carried out where a power socket is not

Download Pdf Manuals

image

Related Search

Related Contents

Jet Tools DC-1100G User's Manual  Whirlpool Micro oven User's Manual  User Guide - Blue Link  MUSTANG FLOOR BY FENDER  Suncast CPLRCH200 Instructions / Assembly  ダウンロード  Addtron Technology WebNet Network Card User Manual  manual de instruções do multímetro digital modelo md  Sitecom WLX-2005 N300 Wi-Fi Wallmount Access Point  NORME GENERALI DI SICUREZZA - General safety  

Copyright © All rights reserved.
Failed to retrieve file