Home
Digi-Tool – CU-210D
Contents
1. How ELECTRONIC ENGINEERING LTD Digi Tool CU 210D Calibration Unit for CSB 200 Digilon Microwave barrier USER MANUAL P N 7111202 Rev B Y S The Digi Tool CU 210D is a special calibration and testing unit designed for setting up the CSB 200 Digilon The Digi Tool provides the adjustment of the following signals and parameters Informational messages indication Distance determine and thresholds detecting method Frequency modulation selection Tuning Setting the speed lower limit Setting the speed highest limit Setting the detection range Setting threshold low level Setting threshold high level Connection 1 1 Digi Tool Connection to the CSB 200 Sensor s is carried out through test connector RJ 11 located inside the receiver unit 1 2 The Digi Tool s connections and power supplies are carried out from the CSB 200 1 3 Digi Tool is connected to the CSB 200 processor and enables recording the memory status of signals before the installations and also performs and records new installations Control and Indications 1 4 The DIGI TOOL includes three control buttons 1 P mode 2 lt less 3 P more 1 5 The DIGI TOOL includes an LCD panel to display the setting mode and testing and setting parameters Operation and setting up the CSB 200 1 6 To test CSB 200 operation it is necessary to remove the Receiver top cover and connect the Digi Tool to the on board RJ 11 socket the m
2. all the three mentioned modes 1 10 Mod Freq Frequency modulation setting There are two options accompanied by following messages Main major value Altern additional value Simultaneously with change of CSB 200 Receiver modulation frequency value it is necessary to change Transmitter modulation frequency value by using the jumper marked F mod in the Transmitter unit Change of modulation frequency is necessary in case that there is more then one system working in the same area in order to prevent influence of neighbor s system transmitter radiation on the sensor s operation See the user manual of the CSB 200 Digilon 1 11 Tuning Tuning Mode In this mode there is indication of the receiving signal level in decibels Tune from 2 up to 70 For convenience the signal partially 20 dB is displayed by a linear scale initial value of a linear scale during tuning changes automatically In this mode following messages can be formed Ranget overcoming of the signal value the limits of the working range Flashing of numerical value of the coming signal displays extreme values for this signal defect of functioning caused by change of external conditions The maximal duration of the tuning mode is 5 minutes after this time the Detector automatically set back to operation mode To enter the Tuning mode again press button Mode once again In this mode and after leaving it there is recording of
3. of the LCD screen
4. assage CSB should appear on the LCD screen after the connection 1 7 In order to set the required mode Press button P the inscription Indic appears on the LCD screen that corresponds to the first mode MESSAGE INDICATION Using buttons lt d or gt choose the required mode The symbol in left bottom corner of LCD indicates the possibility of entering the chosen mode The second pressing of button P will set the mode Calibration Modes 1 8 indic message indication mode there are five following messages Pow Power supply is lower than normal A Forming of alarm signal LL Passing of the Low threshold PL Passing of the positive threshold HL Passing of the High threshold 1 9 Method Distance determine and thresholds detecting method there are two options with the following messages Auto automatic Manual manual The selection of a variant or value in this mode is carried out by buttons lt 4 or P To return from the mode and installation saving mode back or forward press button P the process of installation saving initiates and indicates by the flashing rectangular segment in the right bottom corner of the LCD Notes At an automatic variant of distance definition and thresholds detection mode only control of the established values of these parameters is possible at manual you may and should regulate
5. service data in the Receiver processor memory indicated with the flashing rectangular segment in the right bottom corner of LCD screen 1 12 Min speed Mode of setting the lower limit of speed found out at crossing of DZ has three value variants accompanied by messages 0 1 m s 0 2 m s 0 4 m s 1 13 Max speed Mode of setting the higher limit of speed found out at crossing of DZ has three value variants accompanied by messages 4 m s 6 m s 10 m s 1 14 Dist Contr Working Range Mode There are four variants of the values accompanied by messages 10 40 m 30 140 m 120 180 m 150 200 m The flashing of displayed value shows extreme values of the coming signal defect of functioning caused by change of external conditions 1 15 Level L Low Level Threshold Setting Mode There are six variants of the values accompanied by messages 1 dB 2 dB 3 dB 4 dB 5 dB 6 dB 1 16 Level P High Level Threshold Setting Mode There are four variants of the values accompanied by messages 1 dB 2 dB 3 dB 4 dB Note In the Level L and Level P modes in the lowest line of LCD screen for tuning convenience the following is displayed a conditional scale where threshold s value symbol signal value symbol breaking up of the small and positive thresholds is signaled by symbol in the right bottom corner
Download Pdf Manuals
Related Search
Related Contents
RADEMACHER RolloSystems OpenDo T3 controles et fonctions Supermicro PDSLA PMM 8051 - MPB Srl Series Pelco C2458M-F Stereo System User Manual Copyright © All rights reserved.
Failed to retrieve file