1. CPU FAULT Indica che la CPU del repeater guasta necessario inviare il repeater in riparazione o che non c comunicazione con la centrale controllare le connessioni Indicates that the control panel CPU has reset ii iw O DISABLI As per Figure 1 Control panel frontplate P TEST As per Figure 1 Control panel frontplate Pl Q NIGHT MODI As per Figure 1 Control panel frontplate R BATTERY Indicates that the panel batteries are low or inefficient Indicates restoral of the low inefficient battery event S EARTH Indicates voltage dispersion to earth Indicate restoral of the voltage dispersion to earth event T FUSE Indicates that either the AUX or AUX R output is Indicates the restoral of AUX or shorted and the protection fuse has intervened AUX R output shorted event U MAINS Indicates Mains failure Indicates restoral of the Mains failure event V BELLS ACTIVE Indicates that the ALARM NAC output is active W BELLS FAULT Indicates an ALARM NAC output fault Indicates restoral of the ALARM NAC output fault event X BELLS Indicates that the ALARM NAC output is disabled DISABLED Y DIALLER Indicates that the Dialer output is active ACTIVE Z DIALLER Indicates a Dialer output fault Indicates
2. SmartLine frontplate Buttons Keys Access level 1 Access level 2 A 4 scroll keys A V 0K ESC B Push this button to silence Silences turns OFF active outputs with the silenceable SILENCE turn OFF the panel beeper attribute The silenceable outputs will hold silenced status until a new event occurs that releases the outputs automatically The SILENCE button operates as a toggle switch therefore silenced outputs can be unsilenced by pushing the button again C Push this button to clear any active events delete the RESET memory and restore standby conditions D If this button is pressed during If you push this button when pre alarm conditions are EVACUATE active pre alarm conditions not active the system will generate a panel alarm the system will override the programmed pre alarm time and generate an instant alarm i e activate all evacuation warning devices E If you push this button during active pre alarm INVESTIGATE conditions the system will add the preset time to the running pre alarm time this operation can be done once only for input Extinguishant module accessory item commands F If you push this button once the system will disable DISABLE Extinguish commands If you push this button again the EXTINGUISH system will re enable Extinguish commands G If this button is pressed once the system will disable DISABLE automatic extinguish commands generated by the AUTOMATIC Extinguishant module If this button
3. back immediately to the manufacturer for repair Indicates that the CPU re initialized due to control panel shutdown or fault condition P DISABLED Indicates that one or more components of the yellow system zone or output have been bypassed Q TEST Indicates that one or more zones are undergoing yellow tests R ON Indicates that the system is operating On green S DIALLER ON red Indicates that the dialer activation output is active T DISABLE Indicates that the dialer activation output is Indicates restoral of a fault event This FAULT DIALLER disabled or faulty the display will provide the event can be cleared by RESET only LED yellow respective details Level 2 security personnel U Indicates that the sounder flasher activation Indicates restoral of a fault event This DISABLE FAULT output is disabled or faulty the display will condition can be cleared by reset only BELLS yellow provide the respective details Level 2 security personnel V NIGHT MODI BJ Indicates that the panel is operating in night yellow mode Extinguishant module signaling optional system enhancement tool X Indicates disablement of all types of extinguish DISABLE commands via key F refer to the previous EXTINGUISH table 1 5 1 Commands Y Indicates disablement of all types of extinguish DISABLE commands via key F refe
4. event and total A a el On number of pre alarm events oe ne Descr 02 gt 2nd line number of the point in pre alarm status 3rd line description of the point in pre alarm status 4th line Example of successive pre alarm event The total number of pre alarm events will increase but the display will still show the details of the first pre alarm event 1st line progressive number of the pre alarm event and total Pre alarm 01 02 number of pre alarm events poe ne Dieser 02s 2nd line unchanged 3rd line unchanged 4th line unchanged To view the pre alarm events Press W for the successive pre alarm event Press A for the previous pre alarm event 1st line progressive number of the pre alarm event and total alarm 02 number of pre alarm events Pre 02 a ne Descr 0 2nd line number of the zone in pre alarm status 3rd line description of the zone in pre alarm status 4th line 2 5 3 Fault signaling Fault signaling can be generated by a zone or by the dialler alarm NAC fault NAC 24V external loads outputs or by an anomalous condition found by the control panel Example of first fault fault on NAC output 1st line progressive number of the fault event and total number 01 of fault events 2nd line fault type 3rd line description of the output 4th line Example of a successive fault The total number of faults will increase but the display will still show the details of the first fault event 1st line progr
5. press lt SILENCE gt The panel beeper and the silenceable outputs will be silenced until a new event occurs If the panel is operating in Night mode the panel beeper and the silenceable outputs will be unsilenced automatically after the pre set time and the panel will generate pre alarm status If you wish to re activate pre alarm alarm status after pressing the lt SILENCE gt button press the lt SILENCE gt button again pre alarm alarm signaling and the outputs will re activate To clear all alarm fault signaling active and in memory press lt RESET gt If the conditions persist the panel will generate another alarm Indicates that the control panel has been silenced but has not yet been reset The control panel is in alarm or pre alarm status To reset the control panel you must press lt SILENCE gt before pressing lt RESET gt eve e e SMARTLINE INIM User s Manual 2 3 Fault signaling 2 3 1 Note to building occupants Fault LED Inform the person s in charge of the safety of the building and its occupants immediately 2 3 2 Note to Security Personnel You must always ensure that faults are dealt with and cleared as soon as possible However if you wish to stop the fault signaling you can bypass the zone or output concerned Fault LED On Indicates that at least one system fault has been detected View the fault details on the display and ensure that it is dealt with and cleared On LED Off Primary and seconda
6. ELECTRONICS AK SmartLine Conventional Fire Detection Control Panel Extinguishant system Control Panel User s Manual GameOver SMARTLINE INIM User s Manual ELECTRONICS Chapter 1 Description of the Control panel 1 1 Manufacturer s name and address INIM Electronics s r l Via Fosso Antico Centobuchi 63033 Monteprandone AP Italy Tel 39 0735 70 50 07 Tel 39 0735 70 49 12 info inim biz www inim biz 1 2 Device identification details Denomination Conventional Fire Detection Control Panel Model SmartLine Year of Manufacture 2007 1 3 Documentation supplied e User s Manual this manual e Installation and Programming Manual 1 4 Manual details Title SmartLine user manual e Edition Issue 1 0 e Month and year of printing June 2007 e User manual code DCMUINEOSLINE 1 5 Control panel user interface Keypad and LEDs At o x SE ry 2 PRE EXTINGUISH on PS cy a RESET o wY FAULT Q INHIBITED CN STOP EVACUATE of LEV 2 i o_o CH ST MANUAL CPU mur O vv saan A Lev 1 ote PRE ALARM CPU FAU Ben INVESTIGATE e TAT INIM DIALLER ON J NIGHT MODE ELECTRONICS Figure 1 Control panel frontplate 2 Description of the Control panel ete User s Manual SMARTLINE ELECTRONICS 1 5 1 Commands Note For further details refer to the Installation Manual paragaph 5 1
7. ents Log Press lt key gt Log lt OK gt all the recorded events will be shown in chronological order maximum 100 events 1st line progressive number of the last event ere Neer nn gt 2nd line zone description 9 10 06 08 00 3rd line 4th line date and time Press A to scroll the log Test Panel LEDs Press lt key gt Test LED lt OK gt all the panel LEDs will go On briefly Using the Control Panel 11 Copyright The information contained in this document is the sole property of Inim Electronics s r l No part may be copied without written authorization from Inim Electronics s r l All rights reserved ELECTRONICS PASSION SECURITY INIM Electronics s r l Via Fosso Antico Centobuchi 63033 Monteprandone AP Italy Tel 39 0735 70 50 07 Fax 39 0735 70 49 12 email info inim biz www inim biz DCMUINEOSLINE R100 20070627
8. essive number of the fault event and total number 02 of fault events 1 i 2nd line unchanged 3rd line unchanged 4th line To view fault events Press W for the successive fault event Press A for the previous fault event 10 Using the Control Panel ete User s Manual INIM SMARTLINE ELECTRONICS 1st line progressive number of the fault event and total number 2 of fault events Fault 02 0 Ground fault 2nd line fault type 3rd line 4th line 2 5 4 Bypassed and Test Signaling Bypassed signaling can be generated by a zone or an output Test Signaling can be generated only by a zone Example of first bypassed zone event zone 12 bypassed 1st line number of the first bypassed zone and total number of 01 01 bypassed zones A l 2nd line description of the bypassed zone 3rd line 4th line Example of a successive bypassed zone The total number of bypassed zones will increase but the display will still show the details of the first bypassed zone event 1st line number of the first bypassed zone and total number of Disable 01 02 bypassed zones lt r 20 gt o a 2nd line unchanged 3rd line 4th line To view all bypassed zones Press W for the successive bypassed zone Press A for the previous bypassed zone 1st line number of the first bypassed zone and total number of 02 bypassed zones cr 12 gt 2nd line description of the bypassed zone 3rd line 4th line 2 6 View Ev
9. is pressed again the system will re enable automatic extinguish commands generated by the Extinguishant module H If you push this button once the system will disable DISABLE manual extinguish commands If you push this button MANUAL again the system will re enable manual extinguish commands 1 5 2 Visual Signaling LED ON Solid ON Blinking I LCD display J SILENCED Indicates that the system has been silenced yellow K RESET Indicates that reset commands are not allowed INHIBITED during pre alarm alarm events Reset will be yellow allowed when all outputs have been silenced and this LED goes Off L Indicates an alarm condition that is an input ALARM red point detector callpoint input module etc set to generate alarms has detected alarm conditions Description of the Control panel 3 eve e e SMARTLINE User s Manual ELECTRONICS LED ON Solid ON Blinking M Signals a pre alarm condition that is activation PRE ALARM of a zone point detector callpoint etc that is red programmed with a pre alarm time N Signals an active system fault condition The Indicates memory of a cleared fault FAULT yellow display will provide the fault details event To view the restored fault condition details consult the events log using the Main menu Level 1 public O CPU FAULT yellow Indicates trouble with the panel CPU the panel must be sent
10. nto alarm status The total number of alarm events and zones involved will increase however the display will still show the details of the first alarm ist line unchanged 2nd line unchanged 3rd line number of the zone in alarm status SMA TN OTN 4th line total number of alarm events and total number of zones in alarm status Example of several alarm events another call point belonging to I O line of zone 29 goes into alarm status 1st line unchanged fed 2nd line unchanged oa 7AM oe i ee oto OoODdo om Oo O21 3 NR NDN NNy wW NO 3rd line number of the zone in alarm status ow 4th line total number of alarm events and total number of zones in alarm status To view alarm event details Press the A F keys the details of the first alarm in zone 2 will be shown 1st line number of the zone in alarm status 3 0 ae 2nd line description of the zone in alarm status eee 279 line 4th line number of the last zone and total zones in alarm status If no key is pressed within 20 seconds the display will restore to the initial screen 2 5 2 Pre alarm Early Warning and Monitor signaling Signaling is the same for these three event types however Monitor signals are not associated with zones Using the Control Panel 9 SMARTLINE ini User s Manual Example of first alarm a detector belonging to zone 02 goes into alarm status 1st line progressive number of the pre alarm
11. ont view of the Repeater panel The SmartLetUSee LCD Repeater is supported by most control panel models However when it is connected to a SmartLine control panel some of the command buttons are not operational The following keys buttons are operational A 4 V Scroll keys which will allow navigation through menus etc B EVACUATE As per Figure 1 Control panel frontplate C SILENCE As per Figure 1 Control panel frontplate D RESET As per Figure 1 Control panel frontplate E INVESTIGATE As per Figure 1 Control panel frontplate F BUZZER Turns the panel beeper Off G TEST Turns On al the LEDs to verify functionality Repeaters provide the following signals 1 6 1 Display The display provides same event data as the panel For further details refer to Signaling on the display on page 9 1 6 2 LEDs LED ON Solid ON Blinking H SILENCED As per Figure 1 Control panel frontplate I INHIBITED As per Figure 1 Control panel frontplate RESET J As per Figure 1 Control panel frontplate INVESTIGATE Description of the Control panel 5 SMARTLINE LED K ALARM eve e e ELECTRONICS ON Solid As per Figure 1 Control panel frontplate User s Manual ON Blinking L PRE ALARM As per Figure 1 Control panel frontplate M FAULT As per Figure 1 Control panel frontplate N
12. play DIALLER LED ON Dialler LED OnAn alarm event has activated the Dialler DIALLER ON ON Control panel operating LED View Events The events represent the various conditions signaled by the panel and have the following order of importance alarm pre alarm fault bypass test The system displays information regarding real time events of major importance and disregards those of minor importance for example if the system is dealing with three fault events when a pre alarm event occurs the fault events will be disregarded and cleared from the display and the pre alarm will take priority All events are saved to the log and can be viewed 8 Using the Control Panel User s Manual inim SMARTLINE 2 5 Signaling on the display If several events of the same type occur only the first will be shown on the display If several alarms occur the first alarm will remain on the first line of the display and the most recent alarm will be shown on the line below Use the A Y keys to scroll the events on the display 2 5 1 Alarm signaling Example of first alarm a detector belonging to zone 02 goes into alarm status 1st line number of the first zone to go into alarm status Znn i x alarm oe 2nd line description of the first zone in alarm status Fi lt Z e Descr 0 TOT 00m ON Ole Femer 4th line total numbers of alarm events and total number of zones in alarm status Example of first alarm a detector belonging to zone 29 goes i
13. r to the previous AUTOMATIC table 1 5 1 Commands Z Indicates disablement of all types of extinguish DISABLE commands via key F refer to the previous MANUAL table 1 5 1 Commands A1 Indicates that fire extinction is running EXTINGUISH B1 RE EXTINGUISH Indicates activation of the pre extinguish output C1 Indicates trouble with the fire extinction circuits Indicates restoral of a fault event FAULT D1 STOP Indicates that the fire extinction phase has been Indicates restoral of a Stop EXTINGUISH interrupted by means of a remote Hold off unit extinguishant event E1 Indicates a CPU fault The device must be sent Indicates restoral of a fault event CPU FAULT back to the manufacturer for immediate repair 4 Description of the Control panel User s Manual INIM SMARTLINE ELECTRONICS 1 6 Repeater This control panel supports up to four Repeater panels Repeater panels replicate all the information provided by the control panel and allow access to all Level 1 and 2 functions View active events Reset Silence etc but DO NOT allow access to the Main menu STATUS N FAULTS BELLS DIALLER Y K a e ACTIVE w z aa CPU FAULT FAULT B FAULT oJ DISABLED PSO so o SC pes 8 9 tev 2 run wxyz Co LEV 4 21 BATTERY DISABLED DISABLED EARTH ON TEST BUZZER INVESTIGATE SILENCE RESET EVACUATE XR DIB Figure 2 Fr
14. restoral of the Dialler FAULT output fault event Z1 DIALLER Indicates that the Dialer output has been disabled DISABLED Description of the Control panel User s Manual ete SMARTLINE Chapter 2 ELECTRONICS Using the Control Panel 2 1 Note to Security Personnel Attention Insert and turn the key The panel will enable access level 2 The panel will hold level 2 status for 30 seconds 2 2 Danger signaling In the event of fire hazard always follow the fire department approved fire drill 2 2 1 Note to building occupants Alarm LED On Pre alarm LED On Evacuate the building immediately In the event of real danger press the lt EVACUATE gt button to broadcast the alarm and evacuate the building immediately Inform the person s in charge of the safety of the building and its occupants immediately To silence the beeper press lt BUZZER gt 2 2 2 Note to Security Personnel 1 To force the panel into alarm status regardless of its status press lt EVACUATE gt Alarm Pre alarm Reset LED On SILENCE LED On RESET LED On Using the Control Panel At least one zone is in alarm pre alarm status If there is no intervention during a pre alarm the panel will generate an alarm when the pre set pre alarm time expires To request investigation time press lt INVESTIGATE gt and check the building The investigation time cannot be refreshed In the event of a false alarm
15. ry power failure no mains or battery power The system is not working ensure that power is restored as soon as possible CPU LED On The control panel must be sent back to the manufacturer for repair DISABLE FAULT The dialler output is disabled or faulty View specifics on display Press lt RESET gt to DIALLER LED On switch the LED Off DISABLE FAULT The Alarm NAC is disabled or faulty View the log for specifics Press lt RESET gt to BELLS LED On switch the LED Off 2 4 Informative signaling Signaling that does not require specific action NIGHT MODE ON Control panel in Night mode WARNING The panel may have been LED programmed to generate instant alarms During Night mode SILENCE will be held for the pre set silence time only Fault LED Blinking Restoral of a system fault View the log for specifics Press lt RESET gt to switch the LED Off DISABLE Blinking An Alarm NAC output fault has been cleared View the log for specifics FAULT BELLS Press lt RESET gt to switch the LED Off LED DISABLE Blinking A Dialler output fault has been cleared View the log for specifics Press FAULT lt RESET gt to switch the LED Off DIALLER LED CPU LED Blinking The CPU has reset due to shutdown or jamming Check the efficiency of the entire system Press lt RESET gt to switch the LED Off BYPASS LED ON A zone or output has been bypassed View specifics on display TEST LED ON A zone is in Test status View specifics on dis
Download Pdf Manuals
Related Search
GameOver game over gameovergirlhylia gameoverlayrenderer64.dll file gameover zeus gameoverlayui iphone gameoverlayrenderer64 game over store game over sound game over videogames gameovergreggy game over screen game over photos game over oxley game over png game over wiki
Related Contents
IFS1000-WF I&M Manual ケイセイ手動式デルマトーム O Anenigma seguro Guia do Usuário ビジネスニーズに合わせたコンテンツ制作をお手伝いします USER MANUAL Controller Belt Station U9911-BSC U9911 INDUSTRIAL DEHUMIDIFIER OWNER`S SAMSUNG "user manual" M4.0 Debtors - Fresh Computer Systems Directive 90/385/CEE - Laboratoire national de métrologie et d`essais Copyright © All rights reserved.