Home

N-E Color Target 4085 User Manual - Login Page

image

Contents

1. 8 LED Color White LED intensity Middle Circle 0255 P LED Color RedLEDintensity OuterCirdle 0255 Main Control Menu The control board on the fixture base is your interface to access and control CONTROL BOARD all the functions on the unit Its digital display gives you a code view of the options and functions The following will explain each function and its options 000 Menu Up Down Enter DMX Address Red Dimmer Green Dimmer Blue Dimmer White Flash Fade Scroll Snap Scroll Chase Effect Chase Speed Operating Mode I EM FI OCS EN LC oor 2 ee 1 512 0 15 0 15 0 15 0 15 0 15 0 15 0 15 0 15 0 15 _ DMX Address Press Enter to select the start address channel The first display will let you know what operation mode you are in Use the up down keys to select the desired start address Press Enter to confirm Red Dimmer This function allows you to dim the red LED s on the whole module Press Enter use the up down keys to select desired dimmer settings Press Enter to confirm the settings 15 Steps Green Dimmer This function allows you to dim the green LED s on the whole module Press Enter use the up down keys to select desired dim mer settings Press Enter to confirm the settings 15 Steps Blue Dimmer This function allows you to dim the blue LED s on the whole module Press Enter use the up down keys to select desired dimmer settings Press Enter to confirm the settings 15 Steps White Di
2. N DMX 512 Connection The fixture is equipped with 3 pin XLR Sockets for DMX input and output The sockets are wired in parallel Only use a shielded twisted pair cable designed for RS 485 and 3 pin XLR plugs and connectors in order to connect the controller with the fixture or the fixture with another DMX input DMX output Caution At the last fixture the DMX signal needs to be terminated with a terminator Solder a 120 Ohm resistor between the and the signal into a 3 pin XLR plug and plug It in to the last fixture on the signal run Pre manufactured terminator plugs are available for purchase from your Mega Lite dealer HOS DMXT DMX Profile Target Mode A 3 Channel Target Mode P 4 Channel Target Mode H 8 Channel White LED Intenst Strobe CTO Color fade All slow to fast Color Snap All slow to fast 20 39 Macro 6 Target Mode L 9 Channel 2 LED Color Green LED Intensity Inner Circle 0255 po LED Color _ BlueLEDintensity InnerCirele 0255 7 8 LED Color Green LED Intensity Outer Circle 9 LED Color _ BlueLED intensity Outer Circle 0255 Target Mode F 12 Channel 2 LED Color Green LED intensity Inner Circle 0255 8 EDCoor_ Blue LED tensity Inner Circle 0255 4 1 LED Color White LED intensity Inner Circle 0255 8 LEDColor Red LED intensity Middle Circle 0255 6 EDCoor_ Green LED Intensity Middle Circle 0255
3. USER MANUAL Table of Contents Safety Information eurgesernnvnsnsnemnnenmeserneninsnninnnsii 3 SDE CMC CONS EE NE E E A 4 Main Power COMME CUOM EE 5 DMX 512 go og EE EE edecctesa i 5 MP 6 Main Control Menu ssvvsvenveemmmeueneensneee 8 RIOJA THE F NE ua eno r aA 10 Cleaning amp Maintenance s usresrnsnsvnsessennnnnmes 10 Pr a Cee 10 Check that the unit has not been damaged during transport Read all cautions and warnings prior to operation of this equipment Protection Against Fire Fire Maintain a minimum of 1 foot distance from any type of flame Replace fuse only with the specified type and rating Do Not install the unit to close to a heat source Make sure cable are properly secured Maximum surface operating temperature 80 MORO Protection Against Fire AN Electrical Disconnect power before servicing For connection to main power supply proceed to page 5 This unit must be earthed electronically grounded Do not expose unit to rain or moisture AWON Protection Against Mechanical Hazards po Mechanical 1 Use safety chain when hanging unit 2 Use quality clamps or bolts when positioning unit 3 Do not open unit while it is on risk of electrical shock Technical Information Part Numbers Fixture 4085 N E Color Target Mechanical Specifications 11 80 DMX Connectors 3 and 5 pin XLR connectors in out gt BEE p Power Connections Power Conn
4. Channels R G B W Strobe CTO Macro Dimmer Mode L 9 Channels R G B X 3 Mode F 12 Channels R G B W X 3 Rigging the fixture Caution 1 The installations must be carried out by an authorized dealer or trained professional 2 Unit may cause severe injures if you have doubts concerning the safety do not install 3 Unit is to be 24inches away from flammable materials decoration material 4 Use high quality installation equipment to hang unit When rigging a unit it is very important that you follow common safety procedures Rigging requires extensive experience includ ing but not limited to calculating working loads material being used and periodic safety inspections If you lack these qualifica tions do not attempt the installation yourself instead use a professional structural rigger When rigging the unit always be secured with a secondary safety attachment The installation location of the projector has got to be built in the way that it can hold 10 times the weight for 1 hour with out any harming Installation should be checked at least one time a year by a skilled person Cleaning and maintenance Installation Maintenance The operator has to make sure that the unit is operating safely and has the installations and electron ics checked by an expert every 2 years The following points have to be considered during the inspection 1 All screws used for installing the device or part of the device have to be tightly
5. It is necessary to obtain a Return Material Authorization RMA number from your dealer or point of purchase BEFORE any units are returned for repair The manufacturer will make the final determination as to whether or not the unit is covered by warranty Lamps are covered by the lamp manufacturer s warranty Any Product unit or parts returned to MEGA Systems Inc must be packaged in a suitable manner to ensure the protection of such Product unit or parts and such package shall be clearly and prominently marked to indicate that the package contains returned Product units or parts and with an RMA number Accompany all returned Product units or parts with a written explanation of the alleged problem or malfunction Ship returned Prod uct units or parts to 5711 Kenwick St San Antonio TX 78254 USA Note Freight Damage Claims are invalid for fixtures shipped in non factory boxes and packing materials Freight All shipping will be paid by the purchaser Items under warranty shall have return shipping paid by the manufacturer only in the Continental United States Under no circumstances will freight collect shipments be accepted Prepaid shipping does not include rush expediting such as air freight Air freight can be sent customer collect in the Continental United States REPAIR OR REPLACEMENT AS PROVIDED FOR UNDER THIS WARRANTY IS THE EXCLUSIVE REMEDY OF THE CONSUMER MEGA SYSTEMS INC MAKES NO WARRANTIES EXPRESS OR IMPLIED WITH RESPECT TO ANY PRODUCT
6. connected and must not be corroded 2 There must not be any deformations on the housing fixation and installation spots ceiling suspension trussing 3 The electronic power supply cables must not show any damages material fatigue e g porous cables or sediments Further instructions depending on the installation spot and usage have to be adhered by a skilled installer and any safety problems have to be removed Note There is no serviceable parts inside the device except for the LED s Maintenance and service operations are to be carried out by authorized dealers Replacing the fuse Only replace the fuse with the same type and rating Replacing the power cable If the power cable of this device becomes damaged it has to be replaced by authorized dealers or trained professional only Should you have further questions please contact your dealer Parts List 4085 FAN Replacement fan 4085 MPCB Main PCB card 4085 PS Power Supply Warranty Information Limited Warranty Unless otherwise stated your product is covered by a one year parts and labor limited warranty Dichroic filters and glass gobos are not guaranteed against breakage or scratches to coating It is the owner s responsibility to furnish receipts or invoices for verification of purchase date and dealer or distributor If purchase date cannot be provided date of manufacture will be used to determine warranty period Returning an Item Under Warranty for Repair
7. AND MEGA SYS TEMS SPECIFICALLY DISCLAIMS ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE MEGA SYSTEMS SHALL NOT BE LIABLE FOR ANY INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGE INCLUDING LOST PROF ITS SUSTAINED OR INCURRED IN CONNECTION WITH ANY PRODUCT OR CAUSED BY PRODUCT DEFECTS OR THE PARTIAL OR TOTAL FAILURE OF ANY PRODUCT REGARDLESS OF THE FORM OF ACTION WHETHER IN CONTRACT TORT INCLUDING NEGLIGENCE STRICT LIABILITY OR OTHERWISE AND WHETHER OR NOT SUCH DAMAGE WAS FORESEEN OR UNFORESEEN Warranty is void if the product is misused damaged modified in any way or for unauthorized repairs or parts This warranty gives you specific legal rights and you may also have other rights which vary from state to state Mega Lite 5718 Kenwick St san Antonio TX 78238 Ph 210 664 2600 Fax 210 855 6279 www mega lite com info mega lite com
8. in out Thermal Maximum ambient temperature 40 C Maximum surface temperature 60 C Display Digital g9 Fastening System Mounting Yoke 13 5 Size 11 80 L x4 5 W x 13 5 H Size 16 5 x 7 x 14 5 Weight 12 7 lbs Weight 14 7 lbs 4 5 Electrical Specifications LED Quantity 19 Quad Color Red 19 Green 19 Blue 19 White 19 LED Watts each 10 LED refresh rate 4 7k HZ flicker free LED Lifetime 60 000 to 100 000 hours LED Angle 25 Power Input Voltage Universal 100 240V 50 60 Hz Power Consumption Watts 139 TITT Amps 195 3 ER E D E E S B B a aA Distance m Diameter m Control amp Programming Protocol DMX 512 DMX Channels 5 mode of operation Mode A 3 Channel R G B Mode P 4 Channel R G B W Mode H 8 Channel R G B W Strobe CTO Macro Dimmer Mode L 9 Channel R G B x3 Mode F 12 Channel R G BW x3 Operating mode Stand alone Main Power Connection Caution 1 Do not connect fixture to a dimmer system 2 This unit has Auto switching power supply It will respond to 110V or 220V automatically 3 This unit must be earthed electronically grounded 4 Replace fuse only with the specified type and rating The occupation of the connection cable is as follows This fixture is equipped with an electronic power supply that will let the unit operate from 90V to 240V from 50Hz to 60Hz Cable USA Cable EU 110V 220V Connection Connection Y i
9. mmer This function allows you to dim the White LED s on the whole module Press Enter use the up down keys to select desired dim mer settings Press Enter to confirm the settings 15 Steps Flash This function allows you to strobe the LED s on the whole module in White color Press Enter use the up down keys to select desired flash settings Press Enter to confirm the settings Fade Scroll This function allows you to fade the LED s on the whole module from one color to another Press Enter use the up down keys to select desired fade speed settings Press Enter to confirm the settings 15 Steps Flash Scroll This function allows you to change the LED s on the whole module from one color to another Press Enter use the up down keys to select desired color change speed settings Press Enter to confirm the settings 15 Steps Chase Effect This function allows you to select different chase patterns on the whole module Press Enter use the up down keys to select desired chase settings Press Enter to confirm the settings Chase Speed This function allows you to select the speed of the chase that was selected on the Chase Effect Press Enter use the up down keys to select desired chase speed settings Press Enter to confirm the settings 7 DMX Mode Mode A 4 Channels R G B Press Enter to select the desired operating mode Use the up Mode P 4 Channels R G B W down keys to select Press Enter to confirm Mode H 8