Home

MP95800 - S-Products.com

image

Contents

1. INSTRUCTION MANUAL IP PANEL INDICATORS MP95E00 dogem Software STAIN p Transmittors CE Ni i S232 COMPORT Ov BAT a S Products B V Nijverheidscentrum 26 NL 2761JP Zevenhuizen The Netherlands Tel 31 180 633455 Fax 31 180 633644 S Products Inc 35 Kings Highway East Fairfield CT 06825 USA Tel 1 203 331 9546 Fax 1 203 335 2723 E mail info s products com Internet www s products com Document No InstructieMP_Panel cdr Issue 050202 CONTENTS Type overview Specifications Connection diagram Instructions Programming instructions Mp Software Dimensions WARRANTY Our transmitters have a 5 year warranty Follow usage instruction in this manual In case of malfunction return to your supplier SPECIFICATIONS GENERAL INTRODUCTION Our Panel Indicators are devided in the analogue and microprocessor based MP series All MP models are easily programmed via a personal computer with our Point N Click Software loop type analogue readout owered Output alarm input 4 20 Other input HART ATEX LED 95000 REL e LED e e MP95800 LED e e S Products B V Nijverheidscentrum 26 NL 2761JP Zevenhuizen The Netherlands Tel 31 180 633455 Fax 31 180 633644 S Products Inc 35 Kings Highway East Fairfield CT 06825 USA Tel 1 203 331 9546 Fax 1 203 335 2723 E m
2. 4 wire 50 He g C lt 38 m You must quit before changing settings Upload Downlo ud Software PE Y3 3 Software Transmitter 7 Upload Read the configuration from the transmitter 1 File Action Settings Download Write your settings to the transmitter It is possible to save your settings for later use to open a previous configuration or to print the present configuration Either click on File or on one of the icons The large Upload and Download buttons are also located under Action With a transmitter connected use Upload to find out the settings of your transmitter After you made the required selections use Download to program the transmitter Settings is an important menu item Here you can select C or F and the COM port 2 Settings NOTE Make sure to switch Off the on screen readout otherwise you can t alter the settings Transmitter Select the transmittertype connected or use Upload to find out Sensor You may select the input sensor from a list The choice is limited by the transmitter type Thermocouple alloys are mentioned Minimum and Maximum Input values for Output Current start and end Default are the range minimum and maximum of the selected sensor Damping For Hart protocol transmitters only to slow down the output signal Tag 1 and Tag 2 Any comment you d like to add max 16 characters Connection The number of lead wires on your RTD sensor i e Pt100 Filter Set t
3. H 40 C Non Condensing Dimensions 48 x 96 x 116 mm S Products B V P O Box 33 2760 AA Zevenhuizen The Netherlands Phone 31 180 633455 Fax 31 180 633644 Website www s products com E mail info s products com S Products B V Nijverheidscentrum 26 NL 2761JP Zevenhuizen The Netherlands Tel 31 180 633455 Fax 31 180 633644 S Products Inc 35 Kings Highway East Fairfield CT 06825 USA Tel 1 203 331 9546 Fax 1 203 335 2723 E mail info s products com Internet www s products com Document No InstructieMP_Panel cdr Issue 050202 Mp95800 PROGRAMMING not required for factory calibrated panelmeters Open the panel indicator by removing the front bezel and the cover plate Place the cover plate on a soft non scratching surface Place the switch in the programming position 1 Interface 3 Eh he 1 Insert the CD ROM into your computer The Software will start automatically Or you may run SETUP EXE Just follow the on screen instructions Required is at least Windows 95 or NT and 1MB free space 2 Connect the interface to the serial port of your computer Usually COM1 or COM2 Default is set to COM2 3 Attach the interface to the transmitter panel indicator 3 4 Start the installed S PRO Mp software by clicking the S icon First click Upload to read the settings from your meter Try again if you get a communication error Select the re
4. ad 20 Turn potentiometer setpoint LED status lamp for each setpoint Push to read button for each setpoint Adjustable for each setpoint Available for input types RTD Pt100 T C types K J T or E mVDC VDC mA DC or process input All specifications are subject to change without notice For uptodate information and the latest news please refer to Available for input types RTD Pt100 or T C types K J T or E our website at www s products com Available plugin output modules for model MP95800 A3 4 20mA amp 0 1VDC A4 0 20mA amp 0 1VDC AS 4 20mA amp 0 10 VDC A6 0 20mA amp 0 10 VDC Option Interface and PC software for calibration Microprocessor based Indicator MP95800 Display LED 3 5 digit red Read rate 2 5 second Input RTD Pt100 Input T C K J T E Minimum span RTD 25 C Minimum span T C 50 C Linearization On Off selectable Zero drift 0 01 C or 0 02 C C Span drift 0 005 C or 0 01 C C Cold junction drift 0 01 C PC Excitation current RTD 0 1MA Sensor lead resistance RTD 500 Ohm max Sensor lead resist effect 0 001 C Ohm Sensor lead resistance T C 10 kOhm max Open circuit detection Up Down selectable Startup time 20 sec Warmup time 5 Min Supply voltage effect 0 001 V Supply voltage 230 VAC 115VAC 12VDC or 24VDC Ambient temperature 10 to 70 C Storage temperature 20 to 85 C Relative humidity 95 R
5. ail info s products com Internet www s products com Document No InstructieMP_Panel cdr Issue 050202 Display Read rate Accuracy Zero adjustment Span adjustment Zero drift Span drift Decimal point Polarity Connection Voltage drop Dimensions Operation temp Storage temp Relative humidity Available options Display Read rate Accuracy Zero drift Zero adjustment Span drift Span adjustment Overrange indication PM5600 LCD 3 5 digit 2 5 second 0 1 selected span 1999 to 1999 counts 0 to 1999 counts 0 01 C 0 01 C Selectable by DIP switch Selectable by DIP switch Screw terminals 4 5V max 48 x 96 x 80 mm 0 to 60 C 40 to 85 C 95 RH 40 C Non Condensing AA BB EE FF no suffix for standard loop powered 95000 REL series LED 3 5 digit red 2 5 second 0 1 Full scale 0 01 C 20 turn precision potentiometer 0 01 C 20 turn precision potentiometer 1 or 1 automatic PM5650 LED 3 5 digit red 3 second 0 1 selected span 1999 to 1999 counts 0 to 1999 counts 0 01 C 0 01 C Selectable by DIP switch Selectable by DIP switch Screw terminals n a 48 x 96 x 116 mm 0 to 60 C 20 to 85 C 95 RH 40 C Non Condensing AA BB CC DD Display Read rate Accuracy Analog output Zero drift Zero adjustment Span drift Span adjustment PM5650 HH Specifications as PM5650 bu
6. o 50 Hz for Europe and 60 Hz for USA CJ Comp Cold Junction Compensation for Thermocouples Sensor Break Fixation of the loopcurrent on sensor malfunction Output Current Choose min max 4 20 mA or 20 4 mA Mp87000 The 0 1V 10V 0 20mA is automatic Linearization Select On to linearize the input curve or Off if you require the output curve to be the same as the input S Products B V Nijverheidscentrum 26 NL 2761JP Zevenhuizen The Netherlands Tel 31 180 633455 Fax 31 180 633644 S Products Inc 35 Kings Highway East Fairfield CT 06825 USA Tel 1 203 331 9546 Fax 1 203 335 2723 E mail info s products com Internet www s products com Document No InstructieMP_Panel cdr Issue 050202 S Products B V Nijverheidscentrum 26 NL 2761JP Zevenhuizen The Netherlands Tel 31 180 633455 Fax 31 180 633644 S Products Inc 35 Kings Highway East Fairfield CT 06825 USA Tel 1 203 331 9546 Fax 1 203 335 2723 E mail info s products com Internet www s products com Document No InstructieMP_Panel cdr Issue 050202
7. quired parameters and download these into the panel meter NOTE SOME LAPTOP COMPUTERS CANNOT SUPPLY ENOUGH POWER TO PROGRAM THE INDICATOR IN THESE CASES YOU WILL NEED TO SUPPLY THE Mp INTERFACE WITHA 9V_ BATTERY After programming return the switch in the readout position 2 If you don t have an additional module now replace the cover plate and the front bezel If you do have an output module continue at the next chapter S Products B V Nijverheidscentrum 26 NL 2761JP Zevenhuizen The Netherlands Tel 31 180 633455 Fax 31 180 633644 S Products Inc 35 Kings Highway East Fairfield CT 06825 USA Tel 1 203 331 9546 Fax 1 203 335 2723 E mail info s products com Internet www s products com Document No InstructieMP_Panel cdr Issue 050202 OUTPUT MODULE available output options Mp95800 A3 4 20mA amp 0 1 VDC default Mp95800 A4 0 20mA amp 0 1 VDC Mp95800 A5 4 20mA amp 0 10 VDC Mp95800 A6 0 20mA amp 0 10 VDC Take the panel indicator out of its housing Insert the module on to the corresponding headers Replace the panel indicator into its housing Mount the cover plate and the bezel Fill out the labels with the correct values Without the output module display only OPERATING After programming the panel indicator is ready to use Connect the proper sensor or input signal to the rear as indicated on the label If applicable connect your equipment to the outpu
8. t optional output module Connect the correct power supply as indicated on the label S Products B V Nijverheidscentrum 26 NL 2761JP Zevenhuizen The Netherlands Tel 31 180 633455 Fax 31 180 633644 S Products Inc 35 Kings Highway East Fairfield CT 06825 USA Tel 1 203 331 9546 Fax 1 203 335 2723 E mail info s products com Internet www s products com Document No InstructieMP_Panel cdr Issue 050202 S PRO Mp Software General This program uses the basic Windows features like Save Print and Exit We refer to the Windows Help Manual for file handling Without a mouse you can reach the menu items pressing both ALT and the underlined key You can jump between the settings with TAB gt 5 PRO Mp Default e b di Note that you will only get a 1 Eile Action Settings Sensor Loopcurrent readout on screen if the transmitter is connected to a sensor New Open Save Print 3 On Screen 2 Settings Readout In the Sensor display Input Output Current f Prl 00 IEC75 1 sensor you ll see the actual Minimum input value provided Loopcurrent the programmed Maximum i l Linearization sensor is connected Kanea a n Loopcurrent Tag 1 P00 A12345 is a calculated value Tag Z 0 200 i Backlight Click On to start and Off Connection Filter LJ Comp sensor Break O F to quit the Jire C 60 Hz g fe gt l mA on screen display
9. t with alarms Number 2 independent setpoints Rating Maximum 100W non inductive load Setpoints 20 turn potentiometer setpoint Indication LED status lamp for each setpoint Read Push to read button for each setpoint Hysteresis Adjustable for each setpoint Dimensions 48 x 96 x 163 mm Options for PM series indicators See each model for available options 230VAC input 0 20mA 115VAC input 0 20mA 230VAC input 4 20mA 115VAC input 4 20mA 230VAC built in 24VDC transmitter supply 115VAC built in 24VDC transmitter supply 96000 series LED 3 5 digit red 2 5 second 0 1 Full scale ImV digit non isolated except 96850 0 01 C 20 turn precision potentiometer 0 01 C 20 turn precision potentiometer Open circuit Burn out Supply voltage Operating temperature Storage temperature 1 for thermocouples 230VAC or 115VAC 0 to 60 C 20 to 85 C Overrange indication Open circuit Burn out Supply voltage Operating temperature 1 or 1 automatic 1 for thermocouples 230VAC 115VAC or 24VDC 0 to 60 C 20 to 85 C 95 RH 40 C Non Condensing 24 x 72 x 100 mm Relative humidity Dimensions 95 RH 40 C Non Condensing 48 x 96 x 163 mm Storage temperature Relative humidity Dimensions Alarms Number Rating Setpoints Indication Read Hysteresis 2 independent setpoint SPDT Maximum 100W non inductive lo