Home

LED Easy Move Mini Beam & Wash RGBW

image

Contents

1. LED Easy Mini Beam amp Wash RGBW VARYTEC 1 2 3 4 5 7 Table of contents Safety INSTrUCIONS aho ica paid 3 1 1 FOR SAFE AND EFFICIENT OPERATION 0 0 00000sesseseeesesescesseeesseeseeeeeeseeeeeeeseseeeeeeeeees 3 DESIQNALCCMUSE iii dd t 4 2 1 Overhead installation lili cciias 5 INTOdU CIN iaa devapeaxssucvdesaajaasnasteodgesanvasencasdasdasisvagenasbiedwadaveneaiasdeserees 7 3 1 PTOQUCEOVEIVIEW a 7 CONNEC ONS Hr Aust anhand anerkennen 8 4 1 Electrical CONNECTIONS iociniononiininicaricnnariaricaraonidnnad aeaa a aa danna crasas 8 4 2 DIMX COMNMEGCTIONS een ici 8 4 3 DMX connection with 8 ii ai aaa 9 5 1 Str ct re FthEIMEN id td tddi daa 9 DMA Chalino 11 6 1 DMX mode Standard 19 channels 11 6 2 DMX mode Basic 17 channels en a aa 12 Technical ladran ea ak 13 2 16 VARYTEC 1 Safety instructions e This device is suitable for indoor use not outdoors only e All modifications to the device will void the warranty e Repairs are to carry out by skilled personnel only e Use only fuses of the same type and original parts as spare parts e Protect the unit from rain and humidity to avoid fire and electric shocks e Make sure to unplug the power supply before opening th
2. Zoom Choose an automatic mode Choose a sound to light mode Setting the microphone sensitivity Manual setting of pan Manual setting of Pan fine Manual setting of Tilt Manual setting of Tilt fine Manual setting of the speed Manual setting of dimmer red for LED 1 LED 3 Manual setting of dimmer green for LED 1 LED 3 Manual setting of dimmer blue for LED 1 LED 3 Manual setting of dimmer white for LED 1 LED 3 Manual setting of dimmer red for LED 2 LED 4 Manual setting of dimmer green for LED 2 LED 4 Manual setting of dimmer blue for LED 2 LED 4 Manual setting of dimmer white for LED 2 LED 4 Manual setting of the zoom Manual setting of the strobe Manual setting of the dimmer 9 different color macros Different presets of color temperatures Choosing the automatic mode Choosing the sound to light mode No mode is chosen Choosing the stored scene Choosing the automatic mode Choosing the required DMX mode 9 16 VARYTEC UserMode ResetDef Versions Pan 1 Tilt Tilt1 Spee R1 Gi B1 Wi R2 G2 B2 W2 Zoom Stro Lumi Colo Warm Auto Save Set 01 19 01 19 01 19 01 19 01 19 01 19 01 19 01 19 01 19 01 19 01 19 01 19 01 19 01 19 01 19 01 19 01 19 01 19 00 08 Manual assignment of the DMX channel for Pan Manual assignment of the channel for Pan fine Manual assignment of the DMX channel for Tilt Manual assignme
3. 255 255 55 75 95 115 135 155 175 195 215 255 55 255 75 255 Function Pan Pan fine Tilt Tilt fine Speed Pan Tilt fast slow No function Highest speed Dimmer red LED 1 LED 3 Dimmer green LED 1 LED Dimmer blue LED 1 LED 3 Dimmer white LED 1 LED 3 Dimmer red LED 2 LED 4 Dimmer green LED 2 LED 4 Dimmer blue LED 2 LED 4 Dimmer white LED 2 LED 4 Zoom narrow to wide Strobe No function Strobe Dimmer Color Macros No function Red Green Blue 1 White Pink Orange 1 Blue 2 Blue 3 Orange 2 No function Different presets of color temperatures No function Automatic programs 11 16 VARYTEC 6 2 DMX mode Basic 17 channels Channel 4 15 16 17 Value from 0 0 0 226 236 0 17 56 76 96 116 136 156 176 196 216 56 76 Value to 255 255 225 235 255 255 255 255 255 255 255 255 255 255 16 255 255 55 75 95 115 135 155 175 195 215 255 55 255 75 255 Function Pan Tilt Speed Pan Tilt fast slow No function Highest speed Dimmer red LED 1 LED 3 Dimmer green LED 1 LED 3 Dimmer blue LED 1 LED 3 Dimmer white LED 1 LED 3 Dimmer red LED 2 LED 4 Dimmer green LED 2 LED 4 Dimmer blue LED 2 LED 4 Dimmer white LED 2 LED 4 Zoom narrow to wide Strobe No function Strobe Dimmer Color Macros No function Red Green Blue 1 White Pink Oran
4. anical connections have to be carried out according to the European safety standards 3 16 pam VARYTEC 2 Designated use This device was developed for professional use on stages in discos theatres etc The device is only approved for a connection up to 230V 50 60 Hz AC voltage and only for indoor use Regular breaks during operation increase the lifetime of your device Avoid convulsions or any form of forceful impact during the installation or the start up of the device Make sure that the device is not exposed excessive heat humidity or dust at the place of installation Take care that no cables are lying around You would endanger your own safety and also the safety of a third party It is not allowed to operate or store the device in an environment in which spray water rain humidity or fog is expected Humidity or very high atmospheric humidity could reduce the isolation of the device and could cause deathly electric shocks If you use fog devices the device has not be exposed to a direct smoke jet There has to be a safety distance of at least 0 5m between this device and the fog machine Make sure that the saturation of the fog has to enable a visibility of at least 10m The ambient temperature has to be between 0 C and 40 C Avoid direct sunlight and close proximity to heaters You have also to attend it during the transport in closed motor vehicles Operate the device not during thunderstorms Surge voltages could destroy t
5. e housing 1 1 FOR SAFE AND EFFICIENT OPERATION Be careful with heat and extreme temperature Avoid exposing it to direct rays of the sun or near a heating appliance Not put it in a temperature bellow 32 F 0 C or exceeding 104 F 40 C Keep away from humidity water and dust Do not place the set in a location with high humidity or lots of dust Containers with water should not be placed on the set Keep away from sources of hum and noise Such as transformer motor tuner TV set and amplifier To avoid placing on un stable location Select a level and stable location to avoid vibration Do not use chemicals or volatile liquids for cleaning Use a clean dry cloth to wipe off the dust or a wet soft cloth for stubborn dirt If out of work contact sales agency immediately Any troubles arose remove the power plug soon and contact with an engineer for repairing do not open the cabinet by yourself it might result a danger of electric shock Take care with the power cable Never pull the power cable to remove the plug from the receptacle be sure to hold the plug When not using the device for an extended period of time be sure to disconnect the plug from the receptacle Important Damages caused by the disregard of this user manual are not subject to warranty The dealer will not accept liability for any resulting defects or problems Make sure the electrical connection is carried out by qualified personnel All electrical and mech
6. eam It is a powerful device For a successful installation and operation please read this manual carefully 3 1 Product overview WEY 1 Display 6 DMX in XLR 3 pol 2 Menu 7 DMX out XLR 3pol 3 Up 8 Switch On Off 4 Down 9 Fuse 5 Enter 10 Power in P Con 11 Power out P Con 7 16 A A VARYTEC 4 Connections 4 1 Electrical connections If you wish to change the power supply settings see the chapter Appendix Connect the fixture to the mains with the enclosed power cable and plug The earth has to be connected Cable EU Cable US Pin International Brown Black Live L Light blue White Neutral N Yellow Green Green Earth 4 2 DMX connections To make DMX512 connection go ahead like it is described in the picture Make sure that you use shielded cable 3pole or 5pole XLR cables are suitable Important After the last device the line has to be terminated In order to do this you have to solder a 1200 resistor between the pins Data and Data You can solder this end resistor on a 3pin or 5pin XLR Plug this adapter into the DMX output of the device 4 3 DMX connection with terminator Where the DMX cable has to run a long distance or the equipment is operated in an electrically noisy environment like a disco for installations we recommend using a DMX terminator This prevents corruption of the digital control signal by electrical noise The DMX terminator is simply an XLR con
7. ge 1 Blue 2 Blue 3 Orange 2 No function Different presets of color temperatures No function Automatic programs 12 16 VARYTEC 7 Technical data Power supply Voltage Power consumption max Light source LM type Color spectrum Power Number Power Connections Strom in Strom out XLR in out Pan Tilt Controlling Sound to light Automatic Master Slave DMX512 Number of canals Hardware Protection class Suitability Dimensions L B H Weight AC 100 240 V 50 60 Hz 70 W 4in1 Osram LED RGBW 60 W 4x15W P Con P Con 3pol 540 630 235 Yes Yes Yes Yes 17 19 channels IP20 Indoor 301 x 236 x 134 mm 4 37 kg 13 16 14 16 15 16 VARYTEC Importer amp K Braun GmbH IndustriestraBe 2 D 76307 Karlsbad www bkbraun com info bkbraun com 16 16 RoHS COMPLIANT 2002 95 EC
8. he device Unplug the power supply during thunderstorms During the installation the use of the mounting bracket is obligatory Surrounding objects or surfaces should not be in contact with the device Make sure that during the installation and removal of the device the area below the place of installation is basically cordoned off This also applies to implementation of service The device has basically been protected by a suitable safety Make familiar yourself with the functions of the device before start up People without the experience should not handle with the device The most cause of functional disorder is inappropriate handling Do not use chemicals or volatile liquids for cleaning Use a clean dry cloth to wipe off the dust or a wet soft cloth for stubborn dirt For transport use the original packing or designated accessory to avoid damages during the transport For reasons of safety unauthorized changes are forbidden A usage of the device which differs from usages which are described in this manual can cause damages of the device In that case the warranty expires Additional you should notice that every differed usage is related with dangers and can cause e g an electrical short fire electric shock or crash 4 16 VARYTEC 2 1 Overhead installation Danger of life You have to observe the regulations of BGV C1 formerly VBG 70 and EN60598 2 17 Installations are to carry out by skilled personnel only The su
9. nector with a 120 resistor between pins 2 and 3 which is then plugged into the XLR output socket of the last device in the series Please look to the bottom drawings COMMON 2 DMX INPUT DMX DMX OUTPUT 05 Not Used Not Used COMMON DMX INPUT au DMX OUTPUT DMX 8 16 VARYTEC 5 Control Press MENU to reach the first menu and use UP DOWN to get to submenu To open submenu you have to press ENTER here you can also reach other menu items with UP DOWN buttons confirm with ENTER Press MENU to store your settings 5 1 Structure of the menu Menu AddreSet MotorSet AutoProg Mic Cont MICSensy ChanTest NoSigSet Mode Set Submenu 1 ADD 000 512 PanRev TiltRev PanAdj TiltAdj Encoder PanMode GoboAdj Alone Master Alone Master 000 100 Pan Pant Tilt Tilt Speed R1 G1 B1 Wi R2 G2 B2 w2 Zoom Stro Lumi Colo Warm SavScene Auto Music Close Scene Basic User Standard Submenu2 Yes No Yes No 000 255 000 255 Yes No 540 630 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 Function Setting the DMX address Activate or deactivate Pan reverse Activate or deactivate Pan reverse Fine adjusting of Pan Fine adjusting of Tilt Activate or deactivate the feedback Choose the required Pan mode Setting of the
10. njuries and or damaged properties It is not allowed to install the device in the grip area of people If the device may hang from the ceiling or from high beams the use of truss systems is mandatory The device may not be installed so it can swing freely in the room Please note Crashing down items can cause serious injuries Do not install the projector if you doubt the safety of a possible installation form Before installation make sure that the mounting surface has the ability to carry the tenfold point load of the own weight of the device Mount the device with the mounting bracket to your trussing system using an appropriate clamp During overhead installation the device must be always secured by a safety rope which is designed to hold the twelvefold weight of device Only safety ropes with quick release safety fastener elements may be used Hang up the safety rope in the hole of the mounting bracket Direct the rope over the truss or an appropriate fastening point Hang up the end in the fastening element and tie up the locking nut A safety rope once exposed to failing load or damaged may not be used furthermore 5 16 VARYTI The maximum drop exceed must not exceed 20cm A safety rope once exposed to failing load or damaged may not be used furthermore Adjust the desired inclination angle via the mounting bracket and tighten the screw 6 16 VARYTEC 3 Introduction Thank you for buying the LED Easy Move Mini Multi B
11. nt of the DMX channel for Tilt fine Manual assignment of the DMX channel for speed Manual assignment of the DMX channel for dimmer red for LED 1 LED 3 Manual assignment of the DMX channel for dimmer green for LED 1 LED3 Manual assignment of the DMX channel for dimmer blue for LED 1 LED Manual assignment of the DMX channel for dimmer white for LED 1 LED 3 Manual assignment of the DMX channel for dimmer red for LED 2 LED 4 Manual assignment of the DMX channel for dimmer green for LED 2 LED4 Manual assignment of the DMX channel for dimmer blue for LED 2 LED 4 Manual assignment of the DMX channel for dimmer white for LED 2 LED 4 Manual assignment of the DMX channel for zoom Manual assignment of the DMX channel for the strobe Manual assignment of the DMX channel for dimmer Manual assignment of the DMX channel for color macros Manual assignment of the DMX channel for color temperature Manual assignment of the DMX channel for automatic mode Store the manual assignments Reset Shows the current software version 10 16 VARYTEC 6 DMX chart 6 1 DMX mode Standard 19 channels Channel 4 2 3 4 al CoN O 11 12 13 14 15 16 17 18 19 Value from oo o 226 236 O0OoO0O0OOOoOoOo 17 56 76 96 116 136 156 176 196 216 56 76 Value to 255 255 255 255 225 235 255 255 255 255 255 255 255 255 255 16
12. spension devices have to be build and measured so they can withstand for an hour the tenfold of the payload without suffering a permanent detrimental deformation Basically installation has to be made by using a second separate suspension This can be e g a suitable net The second suspension must be designed and attached so no part of the installation can fall down in case of failure During construction reconstruction and deconstruction unnecessary stay in the range of moving areas on lightning bridges under elevated work stations or any other danger zones is forbidden The operator is obliged to following safety related and mechanical facilities Before the first start up or after critical changes before restarting it has to be checked by an expert Review in the frame of the inspection test at least all four years by an expert Review by a qualified person at least once a year How to carry out the overhead installation In tidal fall you should install the device out of the lounge area of people IMPORTANT Overhead installation requires a high level of experience This includes knowledge of calculating the payload used installation material and safety inspections of the used material and the projector whereas the required experience is not limited to this Do not try to carry out installation yourself under any circumstances if you are not qualified Contact a professional installer An inappropriate installation can lead to i