Home
Intelligent Speed Dome Installation Manual (B21) V3.1.0
Contents
1. Note Please contact the technical support of our company if you have any questions 1 5 Installation Installation here includes intelligent analog speed dome intelligent network speed dome intelligent auto tracking speed dome and etc The speed dome has several types of installation brackets You can refer to the chapter 3 to chapter 5 for detailed information Here we are going to install the speed dome in wall mount bracket Step 1 Remove the package and then take out the device Step 2 Open the transparent cover and take out the EPE around the speed dome driver Please remove the protective paster from the driver and take off the camera lens cap See Figure 1 9 Protective Paster Figure 1 9 Step 3 Set Dial Switch of Intelligent Speed Dome Analog Speed Dome Set the parameters of intelligent speed dome address Baud rate and so on There are SW2 and SW3 two dial switches on the PTZ which are used to set the parameters of address Baud rate and so on see Figure 1 10 for more details and see 1 3 Dial Switch Setup For Analog Speed Dome HDCVI Speed Dome for the way to set S W 2 fe SW3 ID N C JA o o Figure 1 10 Step 4 Install the Transparent Cover 1 Please note you need to check the steel wire of the bracket is firmly secure or not 2 Please line up the captive screws to the quadrate groove of the bracket and then push the bracket into the internal enclosure Fix t
2. There are too much devices connected to the RS485 bus And vice versa the max transmission distance shall become longer T 3 The Problem in Practical Use In practical usage we usually adopt star type connection The terminal resistance shall connect to the furthest two devices Such as device 1 and device 15 in Figure 7 1 But this connection way does not conform to RS485 Bus standard When the distances between devices are too long the signal reflection occurs and anti jamming decreases thus the signal reliability becomes very low You can see speed dome is not under control or speed dome is running automatically and can not stop AA P d Br N 4 UA Main Control Device Figure 7 1 In this situation we recommend RS485 distributor This device can turn star type connection into the connection that conforms to RS485 bus industry standard which can avoid the above mentioned problems and enhance communication reliability See Figure 7 2 20 Figure 7 2 7 4 RS485 Bus FAQ Phenomenon Possible Reasons Solution Speed dome e Host address baud rate and Modify host or speed dome setup can run self speed dome address baud rate Switch RS485 positive end and diagnosis but I are not match negative end can not control Positive and negative end of e Fix connection cable firmly it RS485 Bus are misconnected e Replace RS485 Bus Connection cable is loose e
3. RS485 Bus connection are cut off can control e RS485 Bus connection are not Connect RS 485 Bus again the speed good Replace RS485 Bus dome but is not e One RS485 bus is off e Add terminal matching resistance smooth e The distance between host and e Add RS485 distributor speed dome is too far e Parallel connected too much speed domes Note This manual is for reference only Slight difference may be found in the user interface All the designs and software here are subject to change without prior written notice All trademarks and registered trademarks mentioned are the properties of their respective owners If there is any uncertainty or controversy please refer to the final explanation of us Please visit our website or contact your local service engineer for more information 21
4. industry standard System shall adopt equal potential wiring The earth device shall meet anti jamming and at the same time conforms to your local electrical safety code The earth device shall not short circuit to N neutral line of high voltage power grid or mixed with other wires When connect the system to the earth alone the earth resistance shall not be more than 4O and earth cable cross sectional area shall below 25 mm2 See Figure 6 1 Video Lighting Rod Communication __ Lighting Rod Power e Lighting Rod The speed dome shall be installed within the 45 angel of the lighting gt rod Earth cable resistance shall be less than 40 Steel tube shield Figure 6 1 19 7 APPENDIX II ABOUT RS485 BUS 7 1 RS485 Bus Main Feature RS485 is semi duplex communication cable of impedance 1200 Its max load amount is 32 effective loads including main control device and devices to be charged 7 2 RS485 Bus Transmission Distance When we take 0 56mm 24AWG twisted pair as communication cable the max transmission distance theoretically are listed below according to different baud rates Baud Rate Max Distance 2400 BPS 1800M 4800 BPS 1200M 9600 BPS 800M In the following situations the max transmission distance shall become shorter accordingly e The communication cable is a little bit thin e The surrounding environment has strong electromagnetic interference
5. F ON ON OFF OFF OFF OFF OFF 7 ON ON ON OFF OFF OFF OFF OFF 8 OFF OFF OFF ON OFF OFF OFF OFF 254 OFF ON ON ON ON ON ON ON 255 ON ON ON ON ON ON ON ON 1 3 4 Terminal Matching Resistance Setup There is terminal resistance 1200 on the power board There are two connection modes See Figure 1 4 1 2 2 3 1200 ON OFF Figure 1 4 The factory default connection mode is shown as in Figure 1 5 Right now the jumper on the power board Connection board is on the pin 2 and pin 3 The 1200 resistance does not connect to the device D Facotry Default Jump Setup 1200 Resistance Does Not Connect Figure 1 5 If you want to connect the 1200 resistance please remove the jumper from the pin 2 and pin 3 and connect to pin 1 and pin 2 Now the 1200 is connected to the circuit See Figure 1 6 1 2 3 Jumper Setup 1200 Resistance Connected Figure 1 6 1 4 Reset and SD Card Installation Network Speed Dome After opening the speed dome you can see there is a reset button and Micro SD card on the PTZ mainboard see Figure 1 7 for more details Reset button can be used to restore network system and Micro SD card can be used for data storage SD Card Location Reset Button Location Figure 1 7 SD card of network speed dome should be installed on the module see Figure 108 for more details SD Card Location Figure 1 8
6. Intelligent Speed Dome Installation Manual Version 3 1 0 Table of Contents 1 INTELLIGENT SPEED DOME INSTALLATION eere 1 1 1 Installation Preparation sissies eiie deed deed 1 1 2 Initial Setup TE EE E AEE SERIES ERE e e Ope TEEN DESSERT SSL SER 2 1 3 Dial Switch Setup For Analog Speed Dome HDCVI Speed Dome vere versene 2 13 1 Dial Switeh Description dieere tette aaa 2 1 32 Baud hate nie Me ue eher tme tesa etit mote tero nido is 3 UE E E ele E Te eR ome RR OBERE REDE eps 3 1 3 4 Terminal Matching Resistance Setup sse 4 1 4 Reset and SD Card Installation Network Speed Dome eese 4 1 5 O erret ere EE Eeer 5 2 BRACKET DIMENSIONS na 11 2 1 Wall Mount Bracket 4 iaia etta snae tta sos etta sos esta sanete sars rss ind n sa 11 2 2 Gorner Mount AAA dE Eege Eege 11 2 3 PoleiMount Bracket ote O 12 3 WALL MOUNT BRACKET INSTALLATION sssssssssssssssnnnnnnnnsnnnnnnnnnnnnnnnnnnnnnnnnn nn nan 13 3 1 Component Installation ac ooi te tette beta sesoto tse reae eani bote le setae oe 13 3 2 nace SEERE 13 3 2 1 Installation Requirements AAA 13 3 2 2 E E e IEEE EE E E tette nennen nenne tenente tente tenete trennen 13 4 CORNER MOUNT BRACKET INSTALLATION eene 15 4 1 Component Installation 4 1 rts erae nera enata tasa at nn NEAL nennen 15 4 2 Insta
7. Please make sure the screw is completely turned into the bottom of the 96 5 round hole Figure 1 14 4 Use the hex wench to fix the other two M6 10 inner hex stainless screws with spring washer of the bracket to secure the speed dome See Figure 1 15 Two M6 10 inner hex stainless 7 Screw with spring washer Figure 1 15 5 After the installation please use the hex wrench to secure the three M6 stainless screws Please make sure these three M6 stainless screws are firm so that it can secure the speed dome on the wall mount bracket Otherwise there is falling risk of the speed dome if these three screws are not in the proper position Step 6 Secure the Speed Dome Please select the installation wall Please make sure the wall is thick enough to install the expansion bolt Please refer to chapter 3 for detailed information Note The wall can at least sustain the 8x weight of the speed dome bracket and other accessories Step 7 Cable Connection Connect the reserved integration cable of the intelligent speed dome to the corresponding power cable video output cable RS485 control cable alarm input output port if necessary of the multiple function composite cable of the quick installation speed dome Paste the insulating tape in the connection position to do the proper waterproof work Note The video port is covered the heat shrink tube of high shrinking ratio After the video connection please heat the tube to make sure the vi
8. deo port is damp proof and water proof Step 8 The installation of speed dome is completed see Figure 1 16 for more details Figure 1 16 10 2 BRACKET DIMENSIONS 2 1 Wall Mount Bracket The wall mount bracket dimensions are shown as below The unit is mm See Figure 2 1 4 09 i Y e i ls 119 d 8 145 a 235 00 E 0 gt hig E O N e 2 2 2 2 e o Y 58 00 Figure 2 1 2 2 Corner Mount Bracket The corner mount bracket is shown as below The unit is mm See Figure 2 2 11 Figure 2 2 2 3 Pole Mount Bracket The corner mount bracket is shown as below The unit is mm See Figure 2 3 8 57 4 M8 i le FEN 23 gt SS Y TT NM I i FT ay StF 0 130 l O D ERN Figure 2 3 12 3 WALL MOUNT BRACKET INSTALLATION 3 1 Component Installation Wall mount bracket is shown as below See Figure 3 1 Wall mount bracket M6 inner hex stainless screw Figure 3 1 3 2 Installation 3 2 1 Installation Requirements The wall mount speed dome can be installed in the hard construction wall in the indoor or outdoor environments Before the installation please mak
9. e The above can be applied to HDCVI speed dome Set dial switch button Set dial switch button according to control protocol and speed dome address Please refer to user s manual for detailed information Please keep all package material well for future use Please keep speed dome package material well in case you need to send it back to your local retailer or manufacturer for maintenance work Non original package material may result in device damage during the transportation Check Accessories Before the installation please check the accessories one by one according to the packing list Please make sure all the components listed are included 1 2 Initial Setup The default setup is e Address 1 e Baud rate 9600 Party none e 1200 matched resistance OFF 1 3 Dial Switch Setup For Analog Speed Dome HDCVI Speed Dome 1 3 1 Dial Switch Description Before you control the speed dome please set the address baud rate and parity first so that the speed dome can has response to the control command See Figure 1 1 A Note Open the transparent enclosure of the speed dome you can see the dial switch button on the PTZ main board Please follow the steps listed below to set the baud rate address parity and etc After some related information has been reset users have to cut the power and reboot the speed dome to activate new setup SW2 SW3 are the two dial switches on the PTZ of the speed dome which are used to confir
10. e sure e The wall is thick enough to install the expansion bolt e The wall can at least sustain the 8x weight of the speed dome 3 2 2 Installation Steps 1 Please draw four holes position in the wall according to the hole of the bottom of the wall mount bracket Then you can dig four holes and insert the expansion bolts not provided Use four hex bolts and flat washer to fix the bracket in the expansion bolts See Figure 3 2 Figure 3 2 2 Install the speed dome in the bracket Please refer to chapter 1 5 for detailed installation information See Figure 3 3 13 14 4 CORNER MOUNT BRACKET INSTALLATION 4 1 Component Installation Corner mount bracket and its components are shown as below See Figure 4 1 Wall mount bracket M6 inner hex stainless screw Figure 4 1 4 2 Installation 4 2 1 Installation Requirements The corner mount speed dome can be installed in the hard construction wall in the indoor or outdoor environments where there is a 90 degrees angle Before the installation please make sure The wall is thick enough to install the expansion bolt e The wall can at least sustain the 8x weight of the speed dome 4 2 2 Installation Steps 1 Please draw four holes position in the wall according to the holes of the corner installation accessories See Figure 4 2 Installation hole Figure 4 2 Then you can dig four holes and insert the M8 expansion bolts Pull the power cable
11. exceeds the rated load 4 Before you connect the cable install or uninstall or begin the daily maintenance work please turn off the power and unplug the power cable 5 Please make sure the produce is secure firmly on the wall or the ceiling 6 Please turn off the power and unplug the power cable If there is any smoke disgusting smell or noise Please contact your local retailer or customer service centre for help iv 7 Allthe examination and repair work should be done by the qualified service engineers We are not liable for any problems caused by unauthorized modifications or attempted repair Note 1 Safety Transportation Heavy stress violent vibration or water splash are not allowed during transportation storage and installation e This series product must use split type package during the transportation We are not liable for any damage or problem resulting from the integrated package during the transportation 2 When device is malfunction Shut down the device and disconnect the power cable immediately if there is smoke abnormal smell or abnormal function Please contact your local retailer ASAP 3 Do not try to dismantle or modify the device There is risk of personal injury or device damage resulting from opening the shell e Please contact your local retailer if there is internal setup or maintenance requirement Weare not liable for any problems caused by unauthorized modifications or attem
12. hese two captive screws See Figure 1 11 Captive screw Bracket steel wire Quadrate groove of the bracket Bracket e sealing ring Captive screw Captive screw Figure 1 11 Step 5 Wall Mount Bracket Installation 1 Pull the composition cable of the intelligent speed through the other end of the wall mount bracket via the end of column of the wall mount bracket See Figure 1 12 2 Line up the straight line marginal of the wall mount bracket to the straight line marginal of the internal enclosure of the intelligent speed dome Push the intelligent speed dome to the wall mount bracket along the straight line marginal See Figure 1 12 Intelligent speed dome composition cable Straight line marginal of the internal enclosure of the intelligent speed dome Figure 1 12 3 Use the hex wrench to turn the M6 16 inner hex stainless screw of the wall mount bracket to the dp round hole bottom of straight line marginal of speed dome internal enclosure Please note the step here is very important Please make sure the screw is completely turned into the bottom of the 96 5 round hole Otherwise there is falling risk of intelligent speed See Figure 13 and 14 for more details M6 16 inner hex stainless screw with spring washer Only one Intelligent speed dome i composition cable 06 5 round hole of the internal enclosure of the speed dome Figure 1 13 M6 16 inner hex stainless screw with spring washer Only one
13. llation Y 15 4 2 1 Installation Requirements sse enne trennen enne 15 42 2 Installation Steps saco eet er ERREUR UR OR IR REO nt 15 5 POLE MOUNT BRACKET INSTALLATION REE E nennen 17 5 1 Installation Components assinei eiii i rie asi 17 5 2 EC AAA AAA 17 5 2 1 Installation Requirements sse eene eene renere renere renere renere renee ne 17 5 2 2 Installation Steps Reto RI Rb RR RN 17 6 APPENDIX THUNDER PROOF AND SURGE PROTECTION 19 T APPENDIX IL ABOUT RS485 BUS I5 r sgr nsssnds nasdagssnsssnas nasdasssnendnsssnssdasssssssasssr 20 7 1 RS485 Bus Main Feature sssissesssvossss nsdessssonsssssosrsssssnssosssssnrsadesssessesssssdesssessnsessonrssdersnssssssosnsesedessssers 20 7 2 RS485 Bus Transmission Distance 0u00senssnensensnnensonsnnennonsnnennonsnnennonsnnennnsnnennsnsnnennnsnnennennne 20 7 3 The Problem in Practical USO s ssissessssssssssisstssssss svsseessseossssesvesessssesseessnsesassessssssfonsssssnsnesinsssarssressersnses 20 7 4 RS485 B s AAA 21 Welcome Thank you for purchasing our speed dome Please read the following safeguards and warnings carefully before you install or use the product iii Important Safeguards and Warnings Safety Measures 1 Qualified Engineer Needed N The installation engineer or maintenance engineer shall have corresponding CCTV sys
14. m the parameters such as the address Baud rate and parity When the button is ON it is 1 For SW dial switch 1 is the lowest bit and the 8 is the highest bit For SW3 1 is the lowest bit and 4 is the highest bit Intelligent speed dome self adapt PELCO D PELCO P industry standard protocol there is no need to pass dial switch setup for the control protocol 0 EN VH Figure 1 1 2 1 3 2 Baud Rate and Parity The dial switch SW3 is to set speed dome baud rate and parity It ranges from 1 to 4 The 1 and the 2 are to set baud rate The 3 and the 4 are to set parity See Figure 1 2 Figure 1 2 Please refer to the baud rate sheet for detailed information Baud Rate 9600bps 4800bps 2400bps 1200bps Please refer to the parity setup sheet for detailed information 1 3 3 Address Setup Please refer to Figure 1 3 for SW2 address setup The speed dome use dial switch to set address number encode mode adopts binary coding Bit 1 8 is valid bit the highest address bit is 255 Figure 1 3 You can refer to the following sheet for more information Address 1 2 3 4 5 6 Y 8 1 OFF OFF OFF OFF OFF OFF OFF OFF 1 ON OFF OFF OFF OFF OFF OFF OFF 2 OFF ON OFF OFF OFF OFF OFF OFF 3 ON ON OFF OFF OFF OFF OFF OFF 4 OFF OFF ON OFF OFF OFF OFF OFF 5 ON OFF ON OFF OFF OFF OFF OFF 6 OF
15. ment e All installation and operation here should conform to your local electrical safety codes e Before installation please open the package and check all the components are included Please make sure the speed dome installation environment and installation mode can meet your requirement If there is special requirement please contact your local retailer for more information We assume no liability or responsibility for all the fires or electrical shock caused by improper handling or installation Check installation space and installation location intension Please make sure the installation environment has enough space to install the speed dome and its corresponding bracket Please make sure the ceiling wall and the bracket can support the speed dome and its corresponding installation component It shall sustain the 8X weight of the speed dome About cable Please select the cable according to your transmission distance The minimum video coaxial cable requirement is e 75ohm e Full cable with copper conductor 95 knitted copper shield International Model Max Distance Ft M RG59 U 750Ft 229M RG6 U 1 000Ft 305M RG11 U 1 500Ft 457M Note The above can be applied to analog speed dome and network speed dome Max Distance International Model M Ft 720P 25fps 30fps 500M 1640Ft SYV 75 3 720P 50fps 60fps 300M 984Ft 1080P 25fps 30fps 300M 984Ft Not
16. ole accessories to the pole Finally you can use glass cement to the output hole to secure waterproof Clamp and pole bracket connection Pole bracket and the pole connection Figure 5 2 17 Step 2 Please refer to chapter 1 5 for detailed installation information See Figure 5 3 for the complete installation of Speed dome Figure 5 3 18 6 APPENDIX I THUNDER PROOF AND SURGE PROTECTION This series speed dome adopts TVS lighting protection technology It can effectively prevent damages from various pulse signals below 1500W such as sudden lighting and surge While maintaining your local electrical safety code you still need to take necessary precaution measures when installing the speed dome in the outdoor environment The distance between the signal transmission cable and high voltage device or high voltage cable shall be at least 50 meters Outdoor cable layout shall go under the penthouse if possible For vast land please use sealing steel tube under the land to implement cable layout and connects one point to the earth Open floor cable layout is forbidden In area of strong thunderstorm hit or near high sensitive voltage such as near high voltage transformer substation you need to install additional high power thunder protection device or lightning rod The thunder protection and earth of the outdoor device and cable shall be considered in the building whole thunder protection and conform to your local national or
17. pted repair Do not allow other object falling into the device The above mentioned objects in the device may result in fire short circuit or damage Please shut down the device and disconnect the power cable if there is water or liquid falling into the camera Please contact your local retailer ASAP Please pay attention to the camera Avoid the sea water or rain to erode the camera 4 Please make sure there is no metal or inflammable explosive substance in the speed dome e e 5 Handle carefully Do not allow this series product fall down to the ground Avoid heavy vibration 6 Installation Environment Requirement e This series speed dome should be installed in a cool dry place away from direct sunlight inflammable explosive substances and etc This series product shall be away from the strong electromagnetism radiant please keep it away from wireless power TV transmitter transformer and etc 7 Daily Maintenance Please use the soft cloth to clean dust on the shell or you can use soft cloth with cleaning liquid to clean the shell and then use soft cloth to make it dry Do not use gasoline dope thinner or other chemical material to clean the shell It may result in shell transfiguration or paint flake Do not allow the plastic or rubber material to touch the shell for a long time It may result in paint flake vi 1 INTELLIGENT SPEED DOME INSTALLATION 1 1 Installation Preparation Basic Require
18. tem installation certificate or maintenance qualification certificate The installation engineer or maintenance engineer shall have qualification certificate for work at height The installation engineer or maintenance engineer shall have the basic knowledge and operation technique for low voltage cable layout and low voltage electronic cable connection Please read the installation manual carefully and keep it well for future reference We are not liable for any problems caused by unauthorized modifications or attempted repair Lifting Appliance Requirement Please select the proper speed dome installation mode and use the lifting appliances at the safety environment The lifting appliances shall have the enough capacity to reach the installation height The lifting appliances shall have safe performance The precaution measures include two types Warning and Note e Warning It is to alert you there is an optional risk of death or series injury e Note It is to alert you there is an optional risk of damage or property loss Warning 1 Allinstallation and operation here should conform to your local electrical safety codes We assume no liability or responsibility for all the fires or electrical shock caused by improper handling or installation 2 Be sure to use all the accessories such as power adapter recommended by manufacturer 3 Do not connect several speed domes to one power adapter It may result in overheat or fire if it
19. video control cable and the alarm cable Please connect if necessary through the centre hole of the bottom of the corner bracket the waterproof adhesive and the centre of the bracket Please reserve the enough cable connection length and then use the M8 expansion bolt to secure the corer mount bracket chassis on the wall 2 Please refer to chapter 1 5 for detailed installation information See Figure 4 3 15 Figure 4 3 16 5 POLE MOUNT BRACKET INSTALLATION 5 1 Installation Components Pole mount bracket and its components are shown as below See Figure 5 1 Wall mount bracket M6 inner hex stainless screw Figure 5 1 5 2 Installation 5 2 1 Installation Requirements The corner mount speed dome can be installed in the hard construction wall in the indoor or outdoor environments Before the installation please make sure the pole bracket can sustain the 8X weight of the speed dome 1 The diameter of the pole structure shall comply with the installation dimension of the clamp Default factory clamp is six inches for the column of p130 152mm It can work with the pole installation bracket You can adjust the diameter and the value clamp specification is p59 82mm p84 108mm q103 127mm q130 152mm q155 178mm 9180 203mm 9194 216mm 5 2 2 Installation Steps Step 1 Please refer to Figure 5 2 to install clamp and pole bracket Pull the cable out of the pole accessories and then use clamp to fix the p
Download Pdf Manuals