Home
NI RMC-8354 Installation Guide
Contents
1. The National Instruments website is your complete resource for technical support At ni com support you have access to everything from troubleshooting and application development self help resources to email and phone assistance from NI Application Engineers Visit ni com services for NI Factory Installation Services repairs extended warranty and other services Visit ni com register to register your National Instruments product Product registration facilitates technical support and ensures that you receive important information updates from NI A Declaration of Conformity DoC is our claim of compliance with the Council of the European Communities using the manufacturer s declaration of conformity This system affords the user protection for electromagnetic compatibility EMC and product safety You can obtain the DoC for your product by visiting ni com certification If your product supports calibration you can obtain the calibration certificate for your product at ni com calibration National Instruments corporate headquarters is located at 11500 North Mopac Expressway Austin Texas 78759 3504 National Instruments also has offices located around the world For telephone support in the United States create your service request at ni com support or dial 1 866 ASK MYNI 275 6964 For telephone support outside the United States visit the Worldwide Offices section of ni com niglobal to access the branch office we
2. Max turbo frequency single core 3 46 GHz Intel Smart Cache ecececeeseeteeteeeeeeneeneee 8 MB PaCk age sis sido n i E ARR Eh LGA 1156 Hard Disk Drive Capacity anem pinnin en e as Es 500 GB in one two or four drive configurations for maximum capacity of 2 TB maximum usable capacity shown by Windows in RAID 5 is 1 36 TB Interface iia iss chclesecertsenestctetiecvande dehreelecis Serial ATA Memory Standard MeMOTY 0 0 0 eceeceecteeeceeeeeeeeeeeees 1 2 x 1 GB 128 M x 72 bit DDR II SDRAM ECC 1333 MHz 4 GB memory upgrade eee eseeseeseeneeteeneeee 2 x 2 GB 128 M x 72 bit DDR II SDRAM ECC 1333 MHz 8 GB memory upgrade 64 bit OS 4 x 2 GB 128 M x 72 bit DDR II SDRAM ECC 1333 MHz 16 GB memory upgrade 64 bit OS 4 x 4 GB 512 M x 72 bit DDR III SDRAM ECC 1333 MHz Mechanical Overall dimensions standard chassis G1 SM ts sot ssenc cbecescenctucedacuets cannedytaeeneedeeeeens 1U Width cs coe cee cere ce cae eaten eaten i a 437 mm 17 2 in Depths S te eA vere A TT 503 mm 19 8 in Weight with four 500 GB drives 10 75 kg 23 7 Ibs Environmental A Caution If installed in a closed or multiunit rack assembly the rack environment operating ambient temperature may be greater than room ambient temperature Therefore install the equipment in an environment compatible with the maximum ambient temperature Tma the manufacturer specifies Operating temperature 0 eecesesee
3. Environmental Acoustic Emissions Environmental Management Worldwide Support and Services Related Documentation The following documents contain information that you may find helpful as you read this manual CompactPCI Specification PICMG 2 0 R 3 0 e PXI Hardware Specification Revision 2 1 e PXI Software Specification Revision 2 1 e ANSI IEEE Standard 1014 1987 IEEE Standard for a Versatile Backplane Bus VMEbus e ANSI VITA 1 1994 VME64 e NI VISA User Manual e NI VISA Programmer Reference Manual e Read Me First Safety and Electromagnetic Compatibility National Instruments Unpacking Carefully inspect the shipping container and the NI RMC 8354 for damage Check for visible damage to the metal work Check to make sure all hardware and switches are undamaged If damage appears to have been caused during shipment file a claim with the carrier Retain the packing material for possible inspection and or reshipment What You Need to Get Started The NI RMC 8354 kit contains the following items NI RMC 8354 rack mount controller NI RMC 8354 User Manual 2 nicom NI RMC 8354 Installation Guide Windows recovery CD DVD Rack mount kit Front bezel AC power cable refer to Table 1 for a list of AC power cables Table 1 AC Power Cables Power Cable Reference Standards Standard 120 V USA ANSI C73 11 NEMA 5 15 P IE
4. A 32 bit operating system such as Windows XP Pro addresses a maximum of 4 GB The NI RMC 8354 supports dual channel DDR 3 SDRAM unbuffered memory in four 240 pin DIMM sockets The NI RMC 8354 is compatible with ECC memory A Note Supported DIMM sizes are 1 GB 2 GB and 4 GB EN Note National Instruments has tested and verified that the DDR 3 DIMMs we sell work with the NI RMC 8354 We recommend you purchase your DDR 3 DIMM modules from National Instruments Other off the shelf DDR 3 DIMM modules are not guaranteed to work properly Rack Mount Kit A rack mount kit is included for mounting the NI RMC 8354 chassis into a 26 in instrument cabinet AEN Note Ifyour cabinet is less than 26 in deep refer to KnowledgeBase 4GCEKKMT at ni com support for rack mount modification USB Floppy Disk Drive A USB floppy drive is available from National Instruments part number 778492 02 NI RMC 8354 Overview The NI RMC 8354 is a 1U PC server based controller for remote control of PXI chassis The controller provides leading edge processing power with Intel Core 17 Quad Core processors high disk bandwidth with hardware RAID support high I O bandwidth with a PCI Express 2 0 x16 slot and up to 16 GB of memory 6 nicom NI RMC 8354 Installation Guide Safety Information A Caution Before undertaking any troubleshooting maintenance or exploratory procedure carefully read the following caution notices A Caution Overloadin
5. e Power on mode from AC power recovery e Internal external modem ring on Front Panel LEDs e Power indicator e LAN status indicators HDD indicator e System temp overheat and fan fail warning indicator 4 nicom NI RMC 8354 Installation Guide System Management e Monitoring for CPU and chassis environment e CPU thermal trip support e 5 V standby alert LED e Fan speed control NI RMC 8354 Description Figure 1 shows the key features of the NI RMC 8354 front panel For detailed information about the NI RMC 8354 rear panel refer to Chapter 3 O Information in the NJ RMC 8354 User Manual Figure 1 Front View of the NI RMC 8354 1 USB Ports 6 Power Indicator 2 Reset Switch 7 HDD Indicator 3 Power Switch 8 LAN1 Status Indicator 4 Hard Drive Activity Indicator 9 LAN2 Status Indicator 5 Hard Drive Error Indicator 10 System Temp and Fan Warning Indicator The front panel includes the following LEDs e Power indicator glows when the NI RMC 8354 is powered on e LAN status indicators flash when there is activity on LAN1 or LAN2 e Overheat FanFail LED Off Normal On Overheat Flashing Fan failure warning NI RMC 8354 Installation Guide National Instruments 5 Optional Equipment Memory Upgrades You can upgrade the NI RMC 8354 memory to a maximum of 16 GB Note
6. iEn 6 Rack Mount Kiteeseen a aeae spacetse cage a EE E E NA eepate EEEE EOE 6 USB Floppy Disk Driveistssseysssxsceosuesssdesse cantentessevioxssitevasatesseeteedoozasiesensebcassabeeceratesaraivenssds 6 NIRMC 8354 Overview vceveseishcsveletsvadets sis s85 tsss SENSA PES AS SNES AEAEE SE DS ETS 6 Safety Information cccccecccescesceseeseeeeeseesecseceeceecesesesacaecsecaecaecaaeseeaceaeeseeeeeeeeeseesseaseaseateeeaess 7 Chassis Cooling Considerations 18 Providing Adequate Clearance 8 Jostallati t ca cesses cassebeanselseseisdaiscssessedsava dens codes sts EKSEN aA ASNOSI PERNIO hh cis oh thd ak AER SESS Connecting Safety Ground 0 0 ceceeceseseeeceecsceecseeeeseceeeesacsevscsaeseeecseeaeeecsecessesaesevseaeseeessaeatees Connecting to Power SOULCE i scs s ce sseisravetetensssaveedse seven eE EETA EEK aE E piap Sapan dia ieoi Rack Mounting sisone ee wide a R A AA E A AEE aad Installing the Inner Slides cc eceecesssseseceeceeceecesecsecaecsecaeesceaseaeeseeeeeeeeeeeeeeseseseeteeeaees Assembling the Outer Slide Assemblies Installing the Outer Slide Assemblies in the Rack ai Installing the Chassis into the Rack cccccecceseeseesececsecsecseescenseseeseeeeeeeeeeeeeseeceeeeseeeeeaees Qy NATIONAL gt INSTRUMENTS OS Reinstallation arid Recovery 3 0 4 820i eee edn de ee en Cleaning eeeeeeeeeee Exterior Cleaning Specifications cccceeeeeeeee BCH Cal stispevsenteusiey Be eyedeaty
7. C83 Switzerland 220 V SEV Australia 240 V AS C112 Universal Euro 230 V CEE 7 I IV VII IEC83 North America 240 V ANSI C73 20 NEMA 6 15 P IEC83 United Kingdom 230 V BS 1363 IEC83 Japan 100 V ANSI C73 11 NEMA 5 15 P IEC83 The unit comes with the standard 120 V USA cable If you have the incorrect AC power cable contact National Instruments Key Features The NI RMC 8354 offers the performance of a high end PC in a compact 1U rack mountable form factor for controlling a PXI or PXI Express system using a National Instruments remote controller Mainboard Features CPU Intel Core 17 860 Quad Core 2 8 GHz 8 MB Cache LGA1156 Chipset e Intel 3420 chipset Memory e 1 2 GB DDR3 memory standard 1 2 x 1 GB e Maximum memory supported 16 GB DDR3 1333 in 4 DIMM sockets NI RMC 8354 Installation Guide National Instruments 3 Slots e One PCI Express 2 0 x16 slot Video e Matrox G200eW 16 MB DDR2 max resolution 1280 x 1024 HDD 1 x 500 GB or 4 x 500 GB SATA 3 Gbps hard drive JBOD RAIDS5 DVD ROM Slim DVD ROM drive Onboard LAN e 2x Intel 82574L Gigabit Ethernet controller Onboard I O e PS 2 keyboard port e PS 2 mouse port e Serial port e VGA port e Two USB 2 0 ports rear e Two USB 2 0 ports front e Two RJ 45 ports Power Management Features e ACPI ACPM power management e Main switch override mechanism Wake On LAN WOL header e Wake up on keyboard mouse from Soft Off
8. Class A emissions Basic immunity e EN 55011 CISPR 11 Group 1 Class A emissions e AS NZS CISPR 11 Group 1 Class A emissions e FCC 47 CFR Part 15B Class A emissions e ICES 001 Class A emissions Note For the standards applied to assess the EMC of this product refer to the Online Product Certification section A Note For EMC compliance operate this device with shielded cabling Typical data Tested in accordance with ISO 7779 meets MIL PRF 28800F requirements 18 nicom NIRMC 8354 Installation Guide CE Compliance CE This product meets the essential requirements of applicable European Directives as follows e 2006 95 EC Low Voltage Directive safety e 2004 108 EC Electromagnetic Compatibility Directive EMC Online Product Certification Refer to the product Declaration of Conformity DoC for additional regulatory compliance information To obtain product certifications and the DoC for this product visit ni com certification search by model number or product line and click the appropriate link in the Certification column Environmental Management NI is committed to designing and manufacturing products in an environmentally responsible manner NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers For additional environmental information refer to the Minimize Our Environmental Impact web page at ni com environment This pa
9. INSTALLATION GUIDE NI RMC 8354 This guide includes installation information for the NI RMC 8354 For more information about configuring using and maintaining the NI RMC 8354 refer to the WJ RMC 8354 User Manual You can download the user manual in PDF format at ni com manuals Contents Related Documentation i siesicsecsecsecsicseashestdssdscsssesssbeseesbessusanteu sae seacbacsdsuseds sects cecebodbcsbettcstesses 2 NI PACK NG AEE E AA E ONE 2 What You Need to Get Started ey Key Features cc eeeeeseeereeeees see Mainboard Features ics i cc sisccesscceacocog sis vay secuncee sesadetsgedesbeozssostueta soy svdsendbcasetatedenbedasldetecngats 3 CPUa E E E AEN E E A EEES 3 Eo E E EE E E AEE 3 MEmOTY sceninis E A A ERAAI SOUS of secaeesestsiosncaeeiee VIGO niecne HDD DVD ROM Onboard LAN 0 0 ceeceescescesceseeseeeeseceeceeceeceaeeaesaesaecaecaecaecaecaecaecaecaeeaceaaeaaecsecaesaeeaeeaeeas 4 Onboard VO sips tec tapsascesta testa ctsadactsessssess RENEE ASKEA S AAEE NERAKA AP PESARE ra EEE 4 Power Management Features cecceececssceseeceeceneesseceneeaeeeceatenseeseeeaeceeeesaeeeneeseees 4 Front Panel LEDS jiscaseascassidsscesscsessiesssssseisivssissveszaseanin System Management NI RMC 8354 Description bis Optional Equipment ic i4Asi ava AEE EE hema ni aiid ER RE Memory Upgrades i sic Jesssccsbeefeciesetetestussszesoatest sanselTuievared budssadedessdbanwase cs de pasai iedee
10. allation and Recovery A Caution Recovering the OS using the hard drive based recovery or the OS recovery CD DVD erases the contents of your hard disk Before recovering the OS back up any files you want to keep The NI RMC 8354 includes a preinstalled OS from the factory The NI RMC 8354 also includes two methods of restoring reinstalling the OS to your system e Hard drive based recovery stores a factory backup on a separate portion of your hard drive allowing you to restore your server without additional media A Note The hard drive recovery hot key is lt F4 gt To access the hard drive based recovery tool press and hold lt F4 gt when video first appears during the boot process 14 nicom NI RMC 8354 Installation Guide e The NI RMC 8354 also ships with an OS recovery CD DVD you can use to reinstall your operating system onto your hard drive If you need to reinstall your operating system you can use the included OS recovery CD DVD Boot the NI RMC 8354 using the OS recovery CD DVD to recover the OS Note You also may need to update or reinstall software after using the OS reinstallation CD DVD to recover your OS The OS reinstallation CD DVD may contain drivers that are older or newer than the factory installed version of the OS and may not contain the latest RAID drivers To ensure you have the latest drivers go to www intel com and install the Intel Rapid Storage Technology Intel RST RAID software package Note Af
11. bsites which provide up to date contact information support phone numbers email addresses and current events Refer to the M Trademarks and Logo Guidelines at ni com trademarks for more information on National Instruments trademarks Other product and company names mentioned herein are trademarks or trade names of their respective companies For patents covering National Instruments products technology refer to the appropriate location Help Patents in your software the patents txt file on your media or the National Instruments Patents Notice at ni com patents You can find information about end user license agreements EULAs and third party legal notices in the readme file for your NI product Refer to the Export Compliance Information at ni com 1legal export compliance for the National Instruments global trade compliance policy and how to obtain relevant HTS codes ECCNs and other import export data NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS U S Government Customers The data contained in this manual was developed at private expense and is subject to the applicable limited rights and restricted data rights as set forth in FAR 52 227 14 DFAR 252 227 7014 and DFAR 252 227 7015 2010 2014 National Instruments All rights reserved 373190B 01 Juni4
12. ck Attach a long bracket to the rear of the right outer slide as shown in Figure 3 Adjust the outer slide assembly to the proper distance so that the chassis fits snugly into the rack Repeat steps 1 to 3 for the left outer slide Figure 3 Assembling Outer Slide Assemblies as 1 Outer Slide 2 Long Bracket NI RMC 8354 Installation Guide National Instruments 11 Installing the Outer Slide Assemblies in the Rack Use the M5 screws and washers to secure the slide assemblies to the rack as shown in Figure 4 Figure 4 Installing Slide Assemblies into Rack 1 M5 Screws and Washers 2 Slide Assemblies 12 nicom NIRMC 8354 Installation Guide Installing the Chassis into the Rack Follow these steps to install the chassis in the rack 1 Push the inner slides attached to the chassis into the grooves of the outer slide assemblies installed in the rack as shown in Figure 5 Figure 5 Installing Inner Slides into Outer Slides 1 Inner Slides 2 Grooves of Outer Slide Assemblies NI RMC 8354 Installation Guide National Instruments 13 2 Push the chassis all the way to the back of the outer slide assemblies as shown in Figure 6 Figure 6 Installing Chassis Into Rack OS Reinst
13. des main power disconnect Depressing the front panel power switch enables or inhibits the internal power supply A Caution Overloading the circuits may damage supply wiring Do not exceed the ratings on the equipment nameplate when connecting equipment to the supply circuit Power Requirements Measured peak inrush power ON 0 0 197 W Measured idle ccccececesceeesscecsseecescecesseeenees 92 W Measured active 100 CPU eeeceeeseeeeee 203 W Mainboard Socket oa des E aie seach ostvendastest LGA 1156 Chipset dint ia eee Ree eee ene Intel 3420 chipset Memory Slots riroraa Vii Four 240 pin DIMM slots three per channel 1066 1333 16 GB max memory PCI EXPrES Sepen inse One PCI Express 2 0 x16 slot SATA iri ai E EE O A ER ARER Six SATA ports compliant with the Serial ATA 2 0 specification WSR 0101 a SEAE EE EE EE Four USB 2 0 ports Key boat aninissininsninerisinircirinann PS 2 keyboard port MOUSC ies deitrstiertclectchentalsticvetecas blac E PS 2 mouse port DAT E E E EE E A VGA port onboard Matrox G200eW 16 MB DDR2 max resolution 1280 x 1024 DOT Ee I EE A E E E E E AN One RS 232 serial port LAN pri T E T E A Two RJ45 LAN jacks Onboard LAN controller eeeeeceeereeeeeees Intel 82574L Gigabit Ethernet controller CPU CPU a E EA Intel i17 860 Quad Core CLOCK Speed ists iaaceseesssesssbsaeseiis ai 2 86 GHz Operating range is guaranteed by design 16 nicom NIRMC 8354 Installation Guide
14. ement part information Installation of parts with those that are not direct replacements may cause harm to personnel operating the chassis Furthermore damage or fire may occur if replacement parts are unsuitable Modification Do not modify any part of the NI RMC 8354 from its original condition Unsuitable modifications may result in safety hazards NI RMC 8354 Installation Guide National Instruments 7 Chassis Cooling Considerations The NI RMC 8354 is designed to operate in an instrument rack Follow the installation instructions A Caution If installed in a closed or multiunit rack assembly the rack environment operating ambient temperature may be greater than room ambient temperature Therefore install the equipment in an environment compatible with the maximum ambient operating temperature Tma specified in Appendix A Specifications in the NI RMC 8354 User Manual Providing Adequate Clearance Apertures in the front top rear and along both sides of the chassis facilitate power supply and motherboard cooling Air enters through the front and top inlets of the chassis and exits through the fans on the rear of the chassis Place the NI RMC 8354 in an instrument rack so that the fans air outlets and the air inlet apertures along the top and front of the chassis have adequate ventilation Keep other equipment a minimum of 76 2 mm 3 in away from the air outlets on the rear of the chassis Installation Follow
15. g the circuits may damage supply wiring Do not exceed the ratings on the equipment nameplate when connecting equipment to the supply circuit A Caution Risk of explosion if battery is replaced by an incorrect type dispose of used batteries according to instructions This equipment contains voltage hazardous to human life and safety and is capable of inflicting personal injury Chassis Grounding The NI RMC 8354 requires a connection from the premise wire safety ground to the NI RMC 8354 chassis ground The earth safety ground must be connected during use ofthis equipment to minimize shock hazards Refer to the Connecting Safety Ground section for instructions on connecting safety ground Live Circuits Operating personnel and service personnel must not remove protective covers when operating or servicing the NI RMC 8354 Adjustments and service to internal components must be undertaken by qualified service technicians During service of this product the mains connector to the premise wiring must be disconnected Dangerous voltages may be present under certain conditions use extreme caution Explosive Atmosphere Do not operate the chassis in conditions where flammable gases are present Under such conditions this equipment is unsafe and may ignite the gases or gas fumes Parts Replacement Service this equipment only with parts that are exact replacements both electrically and mechanically Contact National Instruments for replac
16. ge contains the environmental regulations and directives with which NI complies as well as other environmental information not included in this document Waste Electrical and Electronic Equipment WEEE K EU Customers At the end of the product life cycle all products must be sent to a WEEE recycling center For more information about WEEE recycling centers National Instruments WEEE initiatives and compliance with WEEE Directive 2002 96 EC on Waste and Electronic Equipment visit ni com environment weee Battery Replacement and Disposal IN Caution Risk of explosion if battery is replaced by an incorrect type Dispose of used batteries according to instructions Battery Directive This device contains a long life coin cell battery If you need San to replace it use the Return Material Authorization RMA process or contact an authorized National Instruments service representative For more information about compliance with the EU Battery Directive 2006 66 EC about Batteries and Accumulators and Waste Batteries and Accumulators visit ni com environment batterydirective NI RMC 8354 Installation Guide National Instruments 19 EFAA ais Riehl BEDE CHE ROHS QO RAA National Instruments 46 p E E TAE va P RREH ey ES ROHS XF National Instruments FE ROHS GRIPE WK ni com environment rohs_china For information about China RoHS compliance go to ni com environment rohs_china Worldwide Support and Services
17. ncludes screw threads and the other two pairs have slots If the short brackets are required for your specific rack mounting configuration use the pair s that fits into your rack best NI RMC 8354 Installation Guide National Instruments 9 Note Rack mounting hardware provided in the accessory kit but not specifically described in the following instructions is for other possible rack mounting configurations not mentioned in this manual Consult any relevant literature provided with the intended rack for specific mounting information before attempting to install the NI RMC 8354 Installing the Inner Slides Follow these steps to install the inner slides to the NI RMC 8354 1 Locate the right inner slide the slide used on the right side of the chassis when facing the chassis front panel 2 Align the four square holes on the right inner slide against the hooks on the right side of the chassis as shown in Figure 2 Securely attach the slide to the chassis with two M4 flathead screws 4 Repeat steps 1 to 3 to install the left inner slide to the left side of the chassis Figure 2 Installing Inner Slides 1 Hooks on Chassis 2 Square Holes on Right Inner Slide 3 Holes for M4 Screws 10 nicom NIRMC 8354 Installation Guide Assembling the Outer Slide Assemblies Follow these steps to assemble the outer slide assemblies 1 2 3 Measure the distance from the front rail of the rack to the rear rail of the ra
18. round To minimize shock hazard make sure the electrical power outlet you use to power the chassis has an appropriate earth safety ground Connecting to Power Source Attach input power through the rear AC inlet using the appropriate AC power cable supplied A Caution Overloading the circuits may damage supply wiring Do not exceed the ratings on the equipment nameplate when connecting equipment to the supply circuit A Caution To completely remove power you must disconnect the AC power cable The power switch allows you to power on the chassis or place it in standby mode Push the power switch to the On position if not already on Observe that all fans become operational and the power indicator is lit Rack Mounting 4 Note The rack mount kit provided with the NI RMC 8354 is intended to work with racks that are 26 to 33 in deep For information about installing the NI RMC 8354 into a rack that is less than 26 in deep refer to KnowledgeBase 4GCEKKMT at ni com support The rack mounting hardware includes e One pair of inner slides to be installed on the chassis e One pair of outer slides to be installed in the rack e Three pairs of short brackets for the outer slides e Bag of assorted fasteners e One pair of long brackets for the rear of the outer slides Caution When mounting the equipment in the rack do not create a hazardous condition due to uneven mechanical loading A Note One pair of short brackets i
19. seereeneeneees 5 to 35 C Tested in accordance with IEC 60068 2 1 Storage temperature wee ese ee esses eeeeeeee 40 to 70 C Tested in accordance with IEC 60068 2 1 and IEC 60068 2 2 NI RMC 8354 Installation Guide National Instruments 17 Relative humidity tested in accordance with IEC 60068 2 56 Operating etree asec testes tie eases aces 10 to 90 noncondensing Nonoperational storage 5 to 95 noncondensing Installation Category eccceeescecesseseeseeseeneenes II Pollution Degree sosososniieeenirin risie 2 Alide nisreen E ENRE 2 000 m Operating location s seeseseeeeeeesrerererrrererereren Indoor use only Acoustic Emissions Sound pressure level at operator position Minimum 2 0 0 eececesececcessesseceecesseeeeeesseeee 53 9 dBA Maximi sessirnir 64 9 dBA Sound power Minimum ssssnesseeseeesseerresrsesrrsrrerrsrrreeresnes 61 6 dBA Maximum cccccccccesceseeeceesecestecssseeeeseees 72 0 dBA Safety This product is designed to meet the requirements of the following standards of safety for information technology equipment e IEC 60950 1 EN 60950 1 e UL 60950 1 CSA 60950 1 4 Note For UL and other safety certifications refer to the product label or the Online Product Certification section Electromagnetic Compatibility This product meets the requirements of the following EMC standards for electrical equipment for measurement control and laboratory use e EN 61326 IEC 61326
20. ter you reinstall or recover your OS you may find shortcuts on the desktop that require you to install specific drivers or software for example video drivers Due to driver and software packaging it was not possible to preinstall this software during the OS installation Cleaning A Caution Always disconnect the AC power cable before cleaning or servicing the chassis Exterior Cleaning A Caution Avoid getting moisture inside the chassis during exterior cleaning especially through the top vents Do not wash the front or rear panel connectors or switches Cover these components while cleaning the chassis Do not use harsh chemical cleaning agents they may damage the chassis Avoid chemicals that contain benzene toluene xylene acetone or similar solvents Clean the exterior surfaces of the chassis with a dry lint free cloth or a soft bristle brush Do not use abrasive compounds on any part of the chassis Specifications This section lists the NI RMC 8354 electrical mechanical and environmental specifications Electrical AC Input Input voltage range ececeseeseeseeseeteeeeeseeseeee 100 to 240 VAC Operating voltage range oo ceecsesseeceseteeees 90 to 264 VAC NI RMC 8354 Installation Guide National Instruments 15 Input frequency ionn nina pee 50 60 Hz Operating frequency range oo cceeeceeee 47 to 63 Hz Input current rating Power disconn ttecsrisen iasa The AC power cable provi
21. these steps to connect devices to the NI RMC 8354 A Caution Because of the risk of high energy gt 240VA the unit must be installed only in a Restricted Access Location 1 Connect a keyboard and mouse to the appropriate connectors on the NI RMC 8354 rear panel 2 Connect the VGA monitor video cable to the VGA connector on the rear panel 3 Optional To boot into LabVIEW RT connect the network cable to LAN jack 1 on the rear panel Refer to Figure 3 1 NJ RMUC 8354 Rear Panel Layout in the NI RMC 8354 User Manual for the location of LAN jack 1 4 Connect the USB serial and parallel devices as necessary to the NI RMC 8354 front and rear panel ports A Caution To minimize shock hazard make sure the electrical power outlet you use to power the NI RMC 8354 has an appropriate earth safety ground Refer to the Connecting Safety Ground section for more information 5 Connect the AC power cable to the AC inlet on the rear panel and to an AC power outlet For more information refer to the Connecting to Power Source section 8 nicom NI RMC 8354 Installation Guide Power on the NI RMC 8354 Verify that the NI RMC 8354 boots If it does not boot refer to the What if the NI RMC 8354 does not boot section of Chapter 5 Troubleshooting in the NI RMC 8354 User Manual Connecting Safety Ground The NI RMC 8354 is designed with a three position NEMA 5 15 style plug for the U S that connects the ground line to the chassis g