Drif2 user manual - Solar Hot Water Parts

image

Contents

1. Kanitti Investments Ltd Description The DIFT2 is a differential thermostat solar controller designed specifically for the domestic solar hot water market It continuously monitors the temperature difference between a tank sensor and a panels sensor and switches an external AC hot water circulation pump to facilitate optimal overall system energy efficiency Boil Protection Water circulation is cut out at a tank temperature of 75 C to protect the tank from boiling and minimize the risk of scalding Freeze Protection Water circulation is initiated when panel temperature drops below 4 5 C and stops when panel temperature reaches at least 7 C to ensure water does not freeze in the pipes For closed loop systems freeze protection can be disabled factory setting Status and Fault Indicators The two status lights visible on the top lid provide information regarding faults and normal operation of the controller The following table summarizes the status and fault indications Technical Specifications Red Green Indication Light Light Standby mode pump off On Off Optimal temperature reached boil protection Panel sensor disconnected a slow Flashing fast Panel sensor shorted T l slow fast Faulty Panel Sensor Operation Factory Setting In case the panel sensor is faulty disconnected or shorted the controller will activate the circulation pump for a period of about 40 sec
2. Red Light Flashing Roof Sensor Lead Fault Disconnect Red Light On Optimal Temperature Reached j Both Lights On Panel Freeze Protection Ac Pease refer to Owners Installation Manual Design and Manutactre by KANITT cant com Identification Pump Power Socket 3 Panel Sensor Connector 6 Panel Red Lamp 2010 Kanitti Investments Ltd All Rights Reserved DIFT2 User Manual Rev B Contact Kanitti Investments Ltd 47B Rambam St Raanana 43601 Israel Tel 972 77 5533881 Fax 972 77 5533882 Accessories Tank Sensor Mylar tube 900mm wires RCA male connector Panel Sensor DR Dezincification Resistant Brass Thermowell 200mm Teflon leads RCA female connector RCA RCA wire for connecting the panel sensor mounted on the solar collectors to the solar controller standard length 18 meters gold plated male RCA connectors
3. onds every 40 minutes as a precaution to avoid potential panel freeze damage This operation will continue until the panel sensor fault is resolved This option is factory selectable Please contact Kanitti for further details Installation Guidelines To increase service life it is recommended to use suppressors RC filters in parallel with the AC pump or to use a water pump with built in suppressors DIFT2 Differential Thermostat for Solar Hot Water Systems Rev B Power supply 220VAC 10 50Hz Load up to 1800W 7 5A Power consumption lt 0 75 VA lt 6 6KW h per year Dimensions W x H x L 130x65x90 5 mm Material flame retardant UV stabilized polycarbonate Color Cool Grey 2C Pump ON differential 4 C Pump OFF differential 1 C Operating Temperature 10 65 C Operating Humidity 10 90 non condensing Panel Sensor DR brass 250 rated sensor thermowell element 3 4 NPT thread Teflon leads heat shrink applied 25x3 1mm mylar tube 105 rated sensor element UL3266 leads All RCA connectors are gold plated SAA Electrical Safety ROHS Tank Sensor Connectors Certifications DIFT2 Rev B Outline KANITTI SOLAR CONTROLLER input 240VAC 50Hz 7 5A 1600W Output max losd 7 5A 1800W FAULT FINDING WHEN POWER IS ON No Lights On Standby Mod Groen Light On Normal Operation Green Light Flashing Tank Sensor Lead Faut Disconnected

Download Pdf Manuals

image

Related Search

Related Contents

Pation heater  Manual - Pioneer    Humax LGB-19DZT User's Manual  9860G_Slim_Manager - Support  Summit Appliance REX204W Use and Care Manual  

Copyright © All rights reserved.
Failed to retrieve file