Home

WinCamD Datasheet

image

Contents

1. Range 190 nm 16 um Smallest pixel 3 2 x 3 2 um Smallest Beam 32 um Imaged Areas 6 3 x 4 8 to 20x15 mm Camera Sensor dependent Featu res Direct measurement see p 3 NEW WinCamD LCM 1 CMOS array with 5 5 um 1 2 amp 4 MPixel Formats available Synchronous Shutter No Comet Tailing Update Rate to 50 Hz with new SuperSpeed USB 3 0 interface cM series is USB 3 0 all others USB 2 0 New stackable MagND Filters cM series only Port powered flexible 3 m cable no external power supply required WinCamD LCM Compact 1 8 x 1 8 x 0 8 20 mm fits tight beam trains FI HyperCal Dynamic Noise and Baseline Correction software Pat Pending EF E CTE Comet Tail Elimination for A gt 900 nm ccD based cameras Pat Pending Digital CCD CMOS cameras with on chip 12 14 16 bit ADC camera dependent b itn cil 4 MB image buffer amp on board microprocessor Window free sensors standard for no fringing 25 000 1 electronic auto shutter 40 us to 1000 ms 1 000 1 SNR 30 60 dB Optical Electrical WinCamD LCM Series Camera Pulsed laser auto trigger amp synchronization With new MagND Filter Shown actual size Isolated Pulse Triggering and Parallel capture on multiple cameras 1 8 x 1 8 x 0 8 Field replaceable image sensors Large area TaperCamD options to 20 x 15 mm p 7 X Ray UV 1310 nm p 8 1475 1680 nm p 10 amp 2 16 um Windows 8 7 Vista and XP 32 and 64 bit PC or Mac Intel using
2. Parallels or BootCamp Applications CW amp Pulsed laser profiling gt gt gt gt gt gt gt gt 2 gt gt gt gt gt gt gt gt gt gt Field servicing of lasers and laser based systems Optical assembly amp instrument alignment Beam wander amp logging BladeCam Series Camera 1 8 x 1 8 x 065 oO oO gt o gt M Measurements F r Coe Peete oram Ee Cee ee l te FEO BBE OR XY LA U N BO iem 81 6 om Pixel i TFIXTIEES 5 K o amp s F S Sms BS pee t em R2 m ele le ip 3 3 Ga st Clip a ZW Majo 1781 6 um 2W Minor 2W Mean Eff diam Yc 2580 3 um Image zoom 2 Aia amp 1 EN 1 LER LI F WinCamD Series Camera 2 40 x 2 65 x 1 12 x0 9 without filter 61 x 67x28 mm WinCamD Datasheet Ver 1310 Page 1 of 11 www dataray com 203 210 5065 DataRay Inc Bella Vista CA New More Powerful Beam Analysis Software Log profile displays no averaging 2Wua 13 5 1103 3 um 2Wua 13 5 ts 1073 3 um mego ium BDelta 987 2 um Pixel 38441 58 7 Scale 00 0 umjdiv Peak 82 9 B 1 0 Without HyperCal With HyperCal 0 3 noise baseline tilt Noise lt 0 1 amp flat baseline Auto Inclusion Region on an Elliptical Beam Automatically isolates the appropriate analysis region With user overrides and multi beam features With 1064 nm Comet Tail W
3. pulse rep rates should be greater than 100 kHz 2 40 x 2 65 x 2 05 61 x 67 x 52 15 mm USB 2 0 for laptops amp desktops 3 m standard thin cable 5 m option USB 3 0 compatible Beam profile Second moment processing RoHS WEEE CE CW beams Pulsed sources free running not triggerable average pulses over the 20 ms exposure period or with frame averaging Mean irradiance limits still apply Contact Application Engineer for options Contact Application Engineer for options 5 um processing resolution for interpolated diameters Absolute accuracy is beam profile dependent 35 um accuracy is frequently achievable Centroid accuracy is also beam dependent It can be as good as 20 um since it is arithmetically derived from all pixels above the centroid clip level Page 11 of 11 www dataray com 203 210 5065 DataRay Inc Bella Vista CA
4. HR TaperCamD UCD12 WinCamD UCD12 with 14 4 x 10 5mm2 25 1FOtaperonthesensot i ssi i i OO TaperCamD20 15 UCD23 WinCamD UCD23 with 20 x 15 mm 2 27 1 FO taper on the sensor 1310 Adds 50 mm C mount tube and long pass filter for 1290 to 1350 nm work UV Camera with 3 mm UG11 filter instead of ND 4 0 Works at 260 through 380 nm IR On chip IR to visible phosphor converter for 1480 to 1600 nm FIR2 16 Complete IR camera for 2 to 16 um Extra cameras are available at a reduced cost and come with Cable Mount and ND filter but no Software or User Manual Confirm with factory Add additional suffix X to the system Part E g WinCamD UHR becomes WinCamD UHR X Accessories EAM 2 Variable Attenuator 93 dB optical dynamic range Max 1 W cm 100 mJ cm CUB amp CUB UV Vis amp UV Beam wedge splitters 396 to 1096 polarization dependent C mount to camera NDO 5 ND1 0 ND2 0 ND3 0 Additional Neutral Density filters in ND 1 steps in stackable C mount threaded holders ND4 0 filter comes as standard with the ND4 0 ND5 0 system See User Manual for curves Add L after ND for use with TaperCamD20 15 e g NDL3 0 M Squared Option for WinCamD USB 2 0 WinCamD Series USB 2 0 M Scan 2 5 um steps 44 mm travel add lens below Order Lens assembly separately UV VIS NIR FIR Focal lengths from 50 1000 mm M2DU WC Other DataRay Profiling Instruments E TN Real Time M Squared Multi plane profiler 0 1 uim resolution on CW las
5. Hz 5 10 Hz 20 kHz 1 000 1 30 60 dB 44 dB 113 dB 2 1011 1 11x11 um NA 14 bit USB 2 0 UCD15 1 9 M Pixel 1600 x 1200 7 1x5 4 4 4 x 4 4 44 um Synchronous 5 10 Hz 75 10 Hz 20 kHz 1 000 1 30 60 dB 44 dB 113 dB 1 6 12 1 NA NA 16 bit USB 2 0 Image amp Intensity Zoom Linear and area filters Image Averaging 1 to continuous Compact design 0 65 Probe style for tight applications UCD23 1 4 M Pixel 1360 x1024 8 8x 6 6 6 45 x 6 45 65 um Synchronous 75 10 Hz 075 10 Hz 20 kHz 1 000 1 30 60 dB 44 dB 113 dB 2 1011 1 NA 15 x 15 um 14 bit USB 2 0 Background capture and subtraction HR 1 3 M Pixel 1280 x 1024 6 6x 5 3 5 2x5 2 52 um Rolling 5 10 Hz NA 20 kHz 1000 1 30 60 dB 44 dB 113 dB 2 10 10 1 1 NA NA 10 bit USB 2 0 XHR 3 1 M Pixel 2048 x 1536 6 5x4 9 3 2x 3 2 32 um Rolling 5 10 Hz NA 20 kHz 1000 1 30 60 dB 44 dB 113 dB 2 10 1011 1 NA NA 10 bit USB 2 0 FIR2 16 HR 308 k Pixel 480 x 640 10 9 x 8 2 17 x 17 7170 um Sampled Array 9 Hz NA NA gt 100 1 gt 20 40 dB 9 dB Call Call NA NA 12 bit USB 2 0 OK we agree that Dynamic Range that includes removable ND filters is also nonsense but some suppliers do this so we offer comparable specification with ND Available in both BladeCam and WinCamD housings Common WinCamD BladeCam Series Specifications Specifications are subject to change without notice Wavel
6. R Economical Telecom beam profiling 1475 to 1600 nm gt DataHay version 3 05U Recall 3 05G C Program Files DataRay_Headfiles IR Head Files winCamDIR1550nm1mW 1mm wcf WinCamD 1 of 1 CCD 1024 by 1024 File Device Hardware Palettes View Setup Options Average Filter Camera P S fa xs xe x amp 8 xlyle c e 1 e a o se Sle Sle 4 p R Click to Setup Trigger input is off 92 9 2Wva 990 um 541 um Ee ee IEEE ee eee eee ee I n O ut Center P an R eset cross H airs M ove O zero Aclick menu Mhold drag WinCamD Series NIR amp TaperCamD NIR for Telecom C amp L bands o 1475 to 1600 nm IR to visible conversion phosphor on Silicon CCD v 25 um FWHM point spread function due to phosphor 70 um for CamIR Adapter v 10 spatial response non uniformity due to phosphor 720 uW to 100 mW for 1 mm diam 1550 nm With 0 02 transmission 1550 7 nm ND filter O e g 10 ms exposure on 1 mW 1 mm diameter beam at 1550 nm 6 v Gamma Signal Incident Irradiance where y 21 414 5 Gamma y correction is included in the software x 24 E m 3 el 1 E 52 1 Q 1500 1550 1600 CamIR Adapter with C mount Wavelength WinCamD Datasheet Ver 1310 Page 10 of 11 www dataray com 203 210 5065 DataRay Inc Bella Vista CA 3 5 1 faceplate to sensor image reduction 46 mm diam x 97 mm long NEW Wi
7. and limitations in the table Your CCD or CMOS chip choice does not affect the system price except for the UCD15 amp UCD23 CCD chips which cost more Part Number Cameratype CCD CMOS chip Suffix if required BladeCam HR XHR UV 1310 NIR WinCamD LCM4 LCM2 LCM1 UV 1310 NIR UCD12 UCD15 UCD23 UHR XHR TaperCamD20 15 UCD23 1310 NIR e g WinCamD UCD12 is a complete working system with a High Resolution CCD sensor with 4 65 um pixels TaperCamD 1310 is a complete working system with a 14 4 x 10 8 mm FO Taper for 1310 nm Part Number Descriptions WinCamD LCM4 1 CCD sensor for CW and pulsed 2048 x 2408 pixels 11 3 x 11 3 mm 5 5 x 5 5 um pixel WinCamD LCM2 5 CCD sensor for CW and pulsed 1600 x 1200 pixels 8 8 x 6 6 mm 5 5 x 5 5 um pixel WinCamD LCM1 2 CCD sensor for CW and pulsed 1024 x 1024 pixels 11 3 x 11 3 mm 11 0 x 11 0 um pixel WinCamD UCD12 2 CCD sensor for CW and pulsed 1360 x 1024 pixels 6 3 x 4 8 mm 4 65 x 4 65 um pixel WinCamD UCD23 5 CCD sensor for CW and pulsed 1360 x 1024 pixels 8 8 x 6 6 mm 6 45 x 6 45 um pixel WinCamD UCD15 1 18 CCD sensor for CW and pulsed 1600 x 1200 pixels 7 1 x 5 4 mm 4 4 x 4 4 um pixel BladeCam HR CMOS sensor for CW and high PRR 1280 x 1024 pixels 6 6 x 5 3 mm 5 2 x 5 2 um pixel also available in WinCamD WinCamD UHR BladeCam XHR CMOS sensor for CW and high PRR 2048 x 1536 pixels 6 5 x 4 9 mm 3 2 x 3 2 uum pixel also available in WinCamD WinCamD X
8. ate is a factor of M smaller 0 45 light at higher angles will be attenuated e The individual fibers at the input end are 6 um pitch with a 5096 core cladding area ratio e Refractive index is 1 81 leading to a front surface reflectivity of 8 3 e Residual distortion is specified by the manufacturer at 3 barrel pin cushion distortion In our experience this distortion is concentrated towards the edges of the field e Residual non uniformity in optical response is generally small and requires no correction but the ability to do so is available in the software e Empty filter holders are available for both TaperCamD sizes e AO0 25 deep extension ring is available with male and female 1 30 20 tpi threads I mager area is shown actual size in mm for WinCamD UCD12 BladeCam HR XHR WinCamD FIR216 2 16 um WinCamD UCD23 WinCam UCD15 WinCamD LCM4 11 3 x 11 3 mm WinCamD LCM2 8 8 x 6 6 mm NDA at gt WinCamD LCM1 11 3 x 11 3 mm 16 7 mm TaperCamD20 15 UCD23 15 26 0 mm 1 30 20 tpi thread 1 0 32 C mount thread TaperCamD20 15 UCD23 PMF 2 27 WinCamD Datasheet Ver 1310 Page 7 of 11 www dataray com 203 210 5065 DataRay Inc Bella Vista CA WinCamD XXXX 1310 High Resolution beam profiling to 1350 nm Image of a 1310 nm beam 100 um diameter 1 5 mW 43 ms Shutter no ND filter The high resolution advantage of 4 65 um square pixels is clearly seen wincamp ucb12 AJ x 2 R Click to Setup T
9. ength Standard 1310 NIR FIR HR UV High dynamic range to 113 dB electronic see notation under chart Pulsed lasers Interface Multiple Heads ISO 11146 Certification Measurable Sources 350 to 1150 nm 350 to 1330 nm Residual silicon response 1290 nm long pass filter and light guard tube provided 1480 to 1680 nm NIR to Visible conversion phosphor Erbium response 40 um FWHM Point Spread Function 2 to 16 and 35 um pixel pitch 640 x 480 pixels 10 9 x 8 2 mm WinCamD FIR2 16 HR 190 to 1150 nm UV converters with wavelength options down to X ray UV resolution to 1m 25 000 1 44 dB continuously variable auto electronic shutter 40 us to 1 0 s Additional 10 000 1 ND filter 5 1 electronic control to give 10 1 Auto trigger sync TTL input trigger TTL output trigger Port Powered USB 2 0 for laptops amp desktops 3 m standard thin cable 5 m option USB 3 0 compatible 1 8 cameras Parallel capture serial read Beam profile Second moment processing RoHS WEEE CE CW beams Pulsed sources CW to 25 kHz with single pulse isolation user configurable Synchronous Asynchronous amp Variable Delay trigger options Software programmable trigger input ve or ve edge 2 kQ impedance Measured Beam Powers Manual Beam Attenuation See the Saturation Beam Power Pulse Energy Graph and Notes below stackable ND 0 5 1 2 3 4 5 available Options EAM 2 4 wheel stepped variable att
10. enuator O to 90 dB CUB and CUB UV 3 to 10 30 arc minute wedge samplers for high power beams Measurement Accuracy accuracy is frequently achievable Centroid accuracy is also beam dependent It can be as good as 1 um since it is arithmetically derived from all pixels above the centroid clip level WinCamD Datasheet Ver 1310 Page 3 of 11 Provided ND 4 0 10 000 1 C mount Neutral Density filters ND 4 0 at 546 nm higher in blue lower in near IR Screw 0 1 um processing resolution for interpolated diameters Absolute accuracy is beam profile dependent 1 um www dataray com 203 210 5065 DataRay Inc Bella Vista CA Measured amp Displayed Profile Parameters Displayed Profiles amp Plots Processing Options Pass Fail display Log data and statistics Relative Power Measurement Fluence Chip depth from front of case filter ring all 0 2 mm current verify with factory Outline and Mounting WxHxD See Drawings Below Camera Head Weight Minimum Computer Requirements PC or Intel Mac Beam Diameter Diameter at two user set Clip levels Beam Fit Ellipticity Centroid Position Gaussian amp Second Moment beam diameters Equivalent diameter above a user defined Clip level Equivalent Slit and Knife Edge diameters Gaussian amp Top Hat profile fit amp fit Equivalent Slit profile Major Minor amp Mean diameters Auto orientation of axes Relative and absolute Intensity We
11. ers Focus Alignment Divergence M Visible and Telecom eamMa B wavelengths Dual Detector 190 nm to 2 4 um Beam R2 0 1 um sampling on CW lasers 0 5 um to 4 mm beam dimensions Dual Detector 190 nm to 2 4 um B E ps 100 um to 23 mm M accessory option ISO 11146 Standard Linear scanning slit CW or Pulsed PRR gt 5 kHz lasers up to 23 x 45 mm eamScope E scanned area 190 nm to 1 8 um WinCamD Datasheet Ver 1310 Page 6 of 11 www dataray com 203 210 5065 DataRay Inc Bella Vista CA TaperCamD for Direct Imaging of Larger Beams TaperCamD20 15 UCD23 series beam profiling cameras are unique to DataRay and offer a larger effective imager area TaperCamD cameras offer direct imaging of the beam without any of the Gaussian beam near field far field issues that arise with the use of beam expansion telescopes They are available in standard 1310 and NIR versions Fiber optic tapers are fused coherent fiber bundles heated drawn and polished to give an output end the size of the imager chip The image is de magnified M 1 from the faceplate input to the imager chip end The taper ends are bonded to the surface of the imager chip using a proprietary DataRay process which eliminates both surface reflections and thermal cycling stress e The PMF Pixel Multiply Factor shown below and on the camera label is entered into the software in order to provide correct diameter readings e NAatthe imager end is 1 0 NA at the input facepl
12. ess the beam power is very high meaning that normal laboratory background can dominate the 1310 nm signal Options are Use no filter and work in a darkened room or with black screening Use a long pass filter which blocks radiation below the wavelength s of interest DataRay supports both options 9 No Filter Operation With no shading or filtering a typical room background level is equivalent to an exposure time of 3 ms i e the background is 1096 of the signal when the exposure time with signal is 0 3 ms This emphasizes the need to suppress the ambient light as far as is possible Working in a darkened lab is the best solution The provided 50 mm long 30 mm OD black anodized C mount tube reduces ambient lab background by a factor of around 4 A100 mm long tube will reduce the ambient lab background by a factor of around 8 With thin black card and tape you can mount your own custom tube off the provided 50 mm C mount extension and customize the ambient suppression shading to your application WinCamD Datasheet Ver 1310 Page 8 of 11 www dataray com 203 210 5065 DataRay Inc Bella Vista CA Long Pass Filter Option DataRay provides the WinCamD XXXX 1310 camera with an angled C mount WCD LPF1290 custom long pass filter with 280 transmission above 1295 nm 50 transmission at 1290 nm 1 transmission at 1285 nm fully blocked below 1250 nm o This filter provides very effective blocking of visible ligh
13. ighted Centroid and Geometric Center Beam Wander Display and Statistics Smoothing Filter Triangular running filter up to 10 FWHM X Y Profiles 2D 3D Plots Zoom to x10 10 32 16 384 or colors or gray scale Contoured display at 10 and 32 color HyperCal Real time electronic baseline correction CTE Comet Tail Elimination Image amp profile averaging 1 5 10 20 Continuous Background Capture and Subtraction User set Capture Block option job files save all WinCamD custom settings for particular test configurations On screen in selectable Pass Fail colors Ideal for QA amp Production Min Max Mean Standard Deviation Up to 4096 samples Rolling histogram based on user s initial input Units of mW uJ dBm or user choice relative to a reference measurement input Fluence within user defined area LCM Series WinCamD UCD12 WinCamD UCD15 WinCamD UHR XHR WinCamD UCD23 BladeCam HR XHR WinCamD WinCamD Series BladeCam HR XHR LCM 5 7 10 7 mm 12 05 mm with MagND 8 6 13 1 mm 5 7 10 2 mm 8 5 13 0 mm 8 0 12 5 mm 5 0 9 5 mm 1 8 x 1 8 x 0 81 2 65 x 2 4 x 0 9 1 8 x 1 8 x 0 45 46 x 46x 20 7 mm 67 x 61 x 23 29 mm 46 x 46 x 11 5 16 5 mm WinCamD 155 gm 5 5 oz BladeCam 42 5 grams 1 5 oz 2 GHz processor or higher running Windows 7 Vista XP 32 or 64 bit 2 GB RAM 200 MB Hard Drive space 1024 x 768 monitor Standard USB 2 0 hi power 500 mA port or USB 3 0 por
14. ith CTE CTE Comet Tail Elimination A gt 900 nm GFit 93 7 o LLL LLL LL aea i a De ae i CR SER GPS GNU dac ca DN NUN o j A 2Wua 13 5 Tir2um Scale radius 30 um 2Wub 50 0 693 7 um Samples taken 146 Max deviation 28 7 um Last deviation 2 18 3 um Mean 9 9um AMS 212 20 um 12 24 Time interval minimum Samples ta be recorded 8132 Replay To ClipBoard M 1 3 Normalize Replay Fast Save as bitmap Scale 600 0 umjdiv Peak 73 6 B 1 1 96 __ToExcel Sequence Off Export to Paint Logarithmic Profile shows more detail near baseline Beam Wander on a drifting Laser The same profile with Averaging amp Log 40 dB display reveals Up to 8192 samples at a User Set interval structure in the wings of the beam at levels below 1 Mean RMS and Max deviation Replay Fast or Slow Export to Excel Paint Bitmap or Clipboard WinCamD Datasheet Ver 1310 Page 2 of 11 www dataray com 203 210 5065 DataRay Inc Bella Vista CA Data Ray Innovation The company that brought you the first Windows based CCD beam profiler the first Camera for confined spaces the first software slider exposure and electronic auto shutter the first standard window free CCD for no fringing the first auto orientation on the ellipse amp the first USB 2 0 beam profiling camera has done it again now with our new USB 3 0 compact 1 format cameras Compact WinCamD cameras Fully featu
15. nCamD FIR2 16 HR Compact Portable Port Powered USB 2 0 10 6 um Beam Profiling for Windows 8 7 XP amp Vista 32 or 64 bit operating systems Features o 17 um pixel pitch 640 x 480 pixels 10 9 mm x 8 2 mm 16 ms time constant oO oO oO gt gt Applications o CO FIR laser profiling Field servicing of CO2 lasers and laser based systems No Chopper Measure Pulsed or CW Beams o Room Temperature no cooling required 2 to 16 um wavelength range microbolometer Port Powered USB 2 0 flexible 3 m cable no power brick 12 bit ADC 4 MB image buffer amp on board microprocessor WinCamD 61 x 67 x 52 15 mm 0 o Optical assembly amp instrument alignment 2 40 x 2 65 x 2 05 1 86 without filter 0 Beam wander amp logging Compact Room Temperature Port Powered WinCamD FIR cameras Features Digital serial link for EMI immunity XY profiles and centroids Linear and logarithmic displays oO oO gt gt o WinCamD FIR Specifications Gaussian and Top Hat least squares fits Ellipse Angle Major Minor Mean Diameters Background capture and subtraction Image amp Intensity Zoom Linear and area filters I mage Averaging 1 to continuous PC Or Mac Intel Operation oO e gt gt o Wavelength Ranges 2 to 16 um Pulsed lasers Compact Interface ISO 11146 Certification Measurable Sources Measured Beam Powers Manual Beam Attenuation Measurement Accuracy WinCamD Datasheet Ver 1310
16. red cameras small enough to fit in your shirt pocket or to fit in a space 0 65 thick Bladecam Features XY profiles and centroids oO gt gt gt Gc WinCamD CCD amp CMOS Sensor Specifications Digital serial link for EMI immunity Linear and logarithmic displays Gaussian and Top Hat least squares fits Ellipse Angle Major Minor Mean Diameters WinCamD LCM4 LCM2 Pixel Count amp 4 M Pixel 2 M Pixel HxV 2048 x 2048 1600 x 1200 Sensor image area mm 11 3 x 11 3 8 8 x 6 6 Pixel dimension pum 5 5 x 5 5 5 5 x 5 5 Min beam 10 pixels 55 um 55 um Shutter type Synchronous Synchronous Max full frame rate 215 Hz 230 Hz Max every pulse PRR 10 Hz gt 30 Hz Single pulse capture PRR 18 Hz 18 Hz Signal to RMS Noise 1 000 1 1 000 1 Opt Elec dB 60 dB 60 dB Electronic Shutter Dynamic Range 63 dB 63 dB ND Shutter SNR Dynamic Range 113 dB 113 dB 2 1011 1 2 1011 1 TaperCamD UCD12 pixel size NA NA TaperCamD UCD20 15 Pixel size 15x15 NA ADC 12 10 bit 12 10 bit Interface USB 3 0 USB 3 0 OK we agree that quoting electrical dB for optical SNR is nonsense but some suppliers do this so we offer a comparable specification LCM1 1M Pixel 1024 x 1024 11 3x 11 3 11x11 110 um Synchronous gt 30 Hz gt 30 Hz 18 Hz 1 000 1 60 dB 63 dB 113 dB 2 1011 1 NA NA 12 10 bit USB 3 0 c gt gt gt Gc UCD12 1 4 M Pixel 1360 x1024 6 3 x 4 8 4 65 x 4 65 47 um Synchronous 5 10
17. rigger input is off St Clip a 13 5 View 53 Tilt 36 Clip b 50 0 2W major 113 um 2W minor 100 um 2W mean 106 um Ellipticity 0 88 Orientation 88 0 Crosshair 0 0 Xc abs 396 um Yc abs 553 um CCD Gain 1 3 ALI 2 KT 2 R Click to Setup Exposure 43 264 ms Auto on 2Wva 113 um 2Wua 100 um 2Wub 57 um CEA 0d L L LL L L L L a LL L L L 4 BENE ENGCE DS LAN Scale 40 0 umdiv Peak 78 996 B T 3 Summary 1 Technology WinCamD XXXX 1310 uses proprietary software and electronics in conjunction with sensors that exhibit residual sensitivity at 1310 nm This is a tailing silicon response and has been observed out to at least 1340 nm The effective Quantum Efficiency QE in this tailing response is around 0 01 i e a factor of around 10 down on the visible response 2 Features Despite the low QE WinCamD XXXX 1310 cameras can be very attractive for 1310 nm region use if the source irradiance is adequate see later The small 5 5 4 65 micron square pixels give much higher resolution than standard NIR cameras The WinCamD shutter exposure of up to 1047 ms is 25 to 30 times greater than that of standard cameras partially compensating the low 1310 nm sensitivity 3 Operational Issues ND filters are not normally used with WinCamD XXXX 1310 unl
18. t Outline and Mounting shown actual size gt 46 mm 1 32 C MOUNT AED gr MAGNETIC MOUNT_ KS A oy N O ff i ne OQ N 22 20 mm VANNI NIA fi TE tH 46 mm M jj N Y j annah jf YY t OY NN Z EM L K2 P i 23 mm A ACTIVE SENSOR AREA 11 3 mm x 11 3 mm 1 OPTICAL FORMAT WinCamD LCM Series With new MagND filter WinCamD Datasheet Ver 1310 67 31 mm 4 __ _1 32 C MOUNT V T N r 20 70 mm 4 f _ SMB TRIGGER E 12 M me f Le 1225mm Joo i Lt d i Y dq a l Pi pz m OF cana Het A K eee J NN J 23 80 mm A D T t I jf ACTIVE SENSOR AREA 10 60 mm see table SENSOR PLANE z5J0 mm 10 80 mm Page 4 of 11 WinCambD series with c mount ND filter MagND Filter adds 0 25 6 35mm only LCM series C mount ND Filter adds 0 2 bmm C mount ND Filter adds 0 2 bmm 17 15 mm y USB 2 0 PORT I 13 97 mm SENSOR PLANE see table www dataray com 203 210 5065 DataRay Inc Bella Vista CA 22 86 mm Saturation Beam Power Pulse Energy Graphs These two graphs allow you to simply determine the approximate maximum CW optical power above or pulse energy below that the standard WinCamD BladeCam configuration can measure for your beam diameter and wavelength without additional attenuation The Sat
19. t e g ambient light or laser pump signal It has a custom construction to minimize fringing effects but can still lead to some fringing due to internal reflections in the filter sandwich and between the filter rear surface and the CCD Filters with lower cut on wavelengths can be obtained to special order Exposure Time Use the graph below to estimate the required exposure time for your beam Maximum Beam Power Note the red line indicating to the maximum power of 100 mW allowed on the CCD Above this level you must use sampling or attenuation to reduce the beam power WinCamD 1310 Sensitivity Limits 5t apc 100 Max Beam Power 100 mW 10 1 10 100 1 000 Exposure in ms 1 t gt s For example to give an 8596 saturation c 0 1 level on the ADC At 1310 nm a 100 micron diameter 2 eo mW beam will require a shutter 0 01 exposure time t of 30 ms At lt 1310 nm t will be lower At gt 1310 nm will be greater 0 001 10 100 1 000 10 000 Beam 13 5 Diameter in microns WinCamD WCD LPF1290 long pass filter CM 50 50 mm tube 3 m cable Software CD User manual WinCamD Datasheet Ver 1310 Page 9 of 11 www dataray com 203 210 5065 DataRay Inc Bella Vista CA WinCamD NI
20. uration Limit assumes The provided ND 4 0 filter in place The electronic shutter set at 40 us its lowest value The ADC gain set at 1 its lowest value The beam onto the ND filter must not exceed 2 5 x Beam diam in mm W or 10 W total power for large beams WinCamD UXXX Series Saturation Power Limits 40 us Exposure ND4 0 filter 85 of ADC CW mw For Lower limits divide by 20 000 Higher amp lower powers are possible with available accessories 13 5 Beam Diameter in mm WinCamD UXXX Series Saturation Energy Limits ND4_0 filter 85 of ADC Individual Pulse Energy This graph is fora single pulse withinthe exposure period uJ Higher amp lower powers are possible with available accessories fi te e LL 0 1 0 01 0 001 13 5 Beam Diameter in mm Relative Exposure vs Wavelength 100 The lower limit in the standard configuration is 10 x the Saturation Limit Use the graph right to estimate for other wavelengths s 300 500 700 900 1100 Wavelength in nm WinCamD Datasheet Ver 1310 Page 5 of 11 www dataray com 203 210 5065 DataRay Inc Bella Vista CA ORDERING INFORMATION 3 Year Warranty Free Software Upgrades 30 Day Sale or Return Evaluation PO A Complete System comprises USB 3 0 2 0 Camera ND 1 2 amp 4 0 filters Software 3 m 10 ft Cable User Manual Generate the Part Number based upon the component descriptions