1. in the network switch and make them in the same LAN Input IP address of outdoor panel in the web browser of PC then input the user name and password the default name is admin the password is 123456 to enter into the following interface Smart Home And Intercom System VI 1 0 0 20130628 160 FES 1 0 0 20130425 160 FH 1 1 2 20190628 ERO OK 1 LAN setting Click LAN icon on the interface to enter into the following interface IP IP address should be unique in the same LAN Mask The default Mask is 255 255 255 0 Gateway It depends on IP address DNS It depends on LAN Server IP It is the same as the IP address of management PC NTP It refers to network time protocol Usually the communication among management center indoor monitor and outdoor panel will be available in the same LAN if they are not in the same LAN you need to set SIP server to support the communication Press Submit button to confirm settings 2 Device setting Click Device icon on the interface to enter into the following interface The settings of build and Unit No should be the same as that of corresponding indoor monitor No It is unique number for the outdoor panel You can have max 9 outdoor panels in one house and you need to distinguish their numbers from 1 to 9 Panel mode unit panel You can choose different ring back tone for the outdoor panel Press Submit button to confirm s
2. voltage DC 12V Rated power 6W Standby power consumption 2 5W Operating temperature 10 C 55 C Relative humidity 20 93 IP Grade IP65 CPU 350MHz RAM DDR2 1Gbit X 2 Flash 16Gbit oO AN DO fF WO PD Package Content Check the package content comma lt i comm lt O oom lt Installation screws Waterproof jacket Screw wrench Nameplate Operation Calling In standby mode press the call button The corresponding indoor monitor will ring Unlock Put your registered IC ID card near the card reader area then it will sound a Di tone and the door is unlocked IP address View Connect outdoor panel and PC in the network switch and make them in the same LAN Install Digital System Upgrade Tool in PC and press search button to view the IP address of the outdoor panel Upgrade Tool E led Image Select P 192 168 12 90 I Reboot Progress D P MAC a 2020513 192 168 2 70 00 1F D0 3F FE 63 1011111 192 168 68 80 00 1F D0 E6 54 70 2029902 192 168 2 79 3 1010903 192 168 68 93 1001010101 192 168 98 74 1011112 192 168 68 86 y 2020130 192 168 98 73 1011115 192 168 68 83 I 1011112 192 168 68 2 00 1 0 F6 1011116 192 168 68 111 00 1F D0 87 1A F5 1011117 197 16R AR RS NN 1FENN F1 7F 01 Search Cancel Click Search icon then the IP address will display in the frame of IP System Setting Connect outdoor panel and PC
3. Installation and Operation Manual For TCP IP Digital System Ommo OO omo ommo oma O amp O slak sba Outdoor Panel m Remark Please follow the user manual for correct installation and testing if there is any doubt please call our tech supporting and customer center Our company applies ourselves to reformation and innovation of our products No extra informing for any change The illustration shown here only used for reference if there is any difference please take the actual product as standard product Model FK 700B8 8 buttons Infrared LEDs Camera Microphone Phototransistor O Gara Omo Call Room No Room No Indicator Card Reader Area Call Management Center Infrared LEDs Camera Microphone Phototransistor Speaker Call Room No Room No Indicator Card Reader Area Call Management Center Model FX 700B4D 4 buttons Infrared LEDs Camera Microphone Phototransistor Model FX 700B4N 4 Buttons Call Room No Room No Indicator Card Reader Area Call Management Center Infrared LEDs Camera Microphone Phototransistor Call Room No Room No Indicator Call Management Center Basic Functions 1 Call indoor monitor or management center 2 Unlock with card 3 Video intercom with indoor monitor or management center 4 Support SIP protocol to communicate with IP phone Technology Parameter Working
4. ettings 3 Access setting Click Access icon on the interface to enter into the following interface Unlock timeout After 1 9 seconds the door lock is open Unlock delay The door lock is open for 0 9 seconds Unlock password no function Elev refer set the floor that outdoor panel exits the parameter is 01 99 6 Card Registration with card reader 1 You can input admin card No directly then click Submit icon to confirm the registration 2 If you don t know admin card No please input 0 in the frame and confirm the setting Make the new admin card approach to the card reader and the outdoor panel will sound a Di tone It indicates that admin card registration is successful 3 You need to use the admin card to register the unlock cards Swipe admin card firstly then swipe the new unlock card within 10 seconds It will sound a Di tone and indicate the unlock card is successfully registered If exceeds the time it will be delayed for 10 seconds Note the admin card cannot be regarded as unlock card and open the door 4 VOIP Click VOIP icon on the interface to enter into the following interface Input the relevant information if you have SIP server 5 Forward Binding Room No You can bind Room No for each button in the Forward setting Click Forward icon on the interface to enter into the following interface Forward Account Settings The indo
5. or monitor can be bound with Room No For example the indoor monitor is on 11th floor its room No is 14 IP address is 192 168 15 100 37x And you want to press the first button to call this indoor monitor first input 1 in Room No Room No can be set as 1 4 or 1 8 and input sip 1114 192 168 15 100 in Account Add the next indoor monitor as the method If want to delete the Account No input the room No firstly then select Remove in the frame Press Submit button to confirm settings And the button arrangement is like this 3004 10002 JE o 6 ExModule It is reserved 7 Advanced Click Advanced icon on the interface to enter into the following interface Advertising no function Quick Call check it to be available It refers to calling management Input SIP address of the specified management center it can be indoor monitor also be other IP phone One Key Call check it to be available Press the room No call button to call the corresponding indoor monitor the floor No of indoor monitor should be set as 0 the room No should be set from 1 8 according to key type Press Submit button to confirm settings 8 8 Default Click Default icon on the interface to enter into the following interface Keset Uetault Settings Click Submin to reset te default Sumi Click Submit icon now all the registered card are deleted system IP add
6. ress cannot be deleted 9 Logout Click Logout icon on the interface to enter into the following interface User Logout Click Submit icon to logout the system CAT 5e RVV2 a 5e Non visual Terminai 1 0 lt CATSe raris optional CAT Se Ngaso Optional Power Lan gt 3 Tngeormontor_ OP Network Switch 3 R sormentor_ Optional cot ahitor Optional 2F Taw205 RW20 5 Terminai 22v emine CAT 5e i a 5 i 5 CAT 5e 4 Terminal Nonvisual Optional ICAT 5e__ Ronwvsual_ Optional Power Lr gt 1F Rvv2 1 0 j Indoor monitor_ Optional Indoor monitor_ Optional RVV2 0 5 Terminal 220v z 7 Power 5 Fiber Optical A Fiber Optical Network switen Transceiver Network Switch Transceiver oco ocmo ommo ommo ock Outdoor Panel eg o Villa District Power Terminal G ormo orro ommo ommo ock Outdoor Panel J9 Four core single mode fiber Four core single mode fiber Four core single mode fiber Terminal Power Four core single mode fiber Network Switch 220V RVV2 0 5 Exit B
7. the magnetic area such as television video recorder etc 2 Do not drop knock or shake the unit 3 Do not put the unit in hot areas If the temperature is too high it will shorten the using life of the unit 4 Do not use the wet dishcloth or volatile cleansers to clean it 5 Do not repair the unit without any professional or else it will harm to yourself or damage the unit 13
8. utton RVV2 1 0 Wall Pane Fiber Optical Transceiver Fiber Optical Fiber Optical Transceiver Transceiver Fiber Optical Transceiver CAT 5e National Standard IAA Management Center Power RVV2 1 0 PC Management Center 10 Outdoor Panel Connection If your lock need a seperate power supply please find the system diagram as follows Network switch ie Seg Exit button connect with the outdoor CAT5e we when you go outside press it 0 EX BUT1 Optional A bh V gS AD GND Optional 485 D sw 485 Dci Flat camera Outdoor panel Help station 12V GND 12V 2A Adapter ON WOO i ON 11 Installation Product size 155 270 50mm Built in box size 142 245 55mm Install size 150 250 60mm Built in Box Outdoor Panel 4PCS screws fix the outdoor panel on built in box Drain hole Break through the cord hole on the bottom of the build in box firstly for water draining Please don t cover the drain hold with the glass cement Gare and Maintenance 1 Do not put the unit near