Home
MODEL NUMBER
Contents
1. 0 0010 4 CAMERA SIDE ca sp atatea aaa pa dai al 4 SECTION 3 INSTALLATION AND ADJUSTMENT 5 CONTENTS OF 5 BASIC INSTALLATION eee eee anna manea ne 6 MANUAL IRIS LENS ADJUSTMENT OPTIONAL LENS 9 DC TYPE AUTO IRIS LENS INSTALLATION AND ADJUSTMENT OPTIONAL 10 BACKFOCUS 11 AUDIO DEFEAT ADJUSTMENT 12 SECTION 4 TROUBLESHOOTING AND MAINTENANCE 14 5 14 PREVENTIVE 15 SPECIFICATIONS anti Dat aa m i a 16 vii KCMU000002 05 30 01 THIS PAGE INTENTIONALLY LEFT BLANK viii KCMU000002 05 30 01 SECTION 1 INTRODUCTION PRODUCT DESCRIPTION FEATURES KC33W4MM camera is a high performance 1 3 black and white observation camera designed for use with Ultrak observation systems It provides a low cost solution for closed circuit television CCTV and security surveillance applications The KC33W4MM camera includes the following features e 1 3 CCD Image Sensor professional level camera chip that achieves a very high quality picture e 4mm Fixed Focus Lens
2. S N Ratio 46dB AGC OFF Electronic Shutter 1 60 1 100 000 sec BLC 60 center BLC ON Sync System External VRI Sync Level 40 IRE Signal Format EIA 525 lines 2 1 interlace Scanning Frequency 15 75KHz x 60Hz V Video Output 1 0Vp p 75 Ohms 6 pin modular jack Audio Output 600 Ohms line level 6 pin modular jack Power Input 6 pin modular jack Lens Mount C CS Mount Mounting Hole 1 4 20 UNC top and bottom Operating Temperature 14 F to 122 F 10 C to 50 C Dimensions 2 2W x 2 0H x 3 7D in 56W x 51H x 94D mm Weight 5 5 oz 155g 16 KCMU000002 05 30 01
3. e Support for Standard CS or C mount Lens e Electronic Iris Automatically adjusts the camera for changes in lighting to ensure an optimal picture at all times Microphone Allows for the monitoring of audio at the camera location e Audio Defeat Switch Allows the audio feature of the camera to be disabled This is important in states or cities that do not allow audio monitoring and recording 1 KCMU000002 05 30 01 FEATURES CONTINUED e interphone Input Allows for accessory connections such as motion sensors alarm contacts and two way intercom boxes e Camera Stand Mount Allows the camera to be mounted to shelves walls ceilings and many other structures e Excellent Picture Quality e Single Cable One cable transmits all information including video audio and alarm signals IMPORTANT To reduce the risk of fire or electric shock do not expose this product to rain or moisture e The KC33W4MM camera may be used in outdoor settings only when used with approved camera housing Contact your sales representative for information e The KC33W4MM camera should never be used outdoors without a housing e user of this equipment is responsible for checking and complying with local state and federal laws and statutes concerning the recording and monitoring of audio signals 2 KCMU000002 05 30 01 SECTION 2 CONTROLS AND CONNECTIONS CAMERA FRO
4. cable or connectors Do not place the cable next to fluorescent lights as interference may result Do not use staples to support the cable as they may damage the cable If the provided camera cable is not long enough do not substitute a telephone cable as it could damage the camera and or the monitor Contact your authorized sales representative to purchase longer cables 9 Plugthe cable into the connector pori ES labeled MONITOR on OFF the back of the MONITOR INTERPHONE camera 8 KCMU000002 05 30 01 BASIC INSTALLATION CONTINUED 10 11 13 Plug the other end of the camera cable into the CAMERA port on the back of the monitor Plug the monitor s power cable into a suitable wall outlet Turn the monitor ON The monitor should display images for the connected camera s For more information on system installation and camera display options refer to the observation monitor or system manual Adjust the lens focus and iris control for an optimum picture MANUAL IRIS LENS ADJUSTMENT OPTIONAL LENS A manual iris lens is used in indoor applications where lighting from windows can considerably affect the light level of the room When using a manual iris lens perform the following 1 Set the El switch to ON Turn the iris ring on the lens to the fully open position Focus the lens to obtain optimum picture To incr
5. C RULES THESE LIMITS ARE DESIGNED TO PROVIDE REASONABLE PROTECTION AGAINST HARMFUL INTERFER ENCE IN A RESIDENTIAL INSTALLATION THIS EQUIPMENT GENERATES USES AND CAN RADIATE RADIO FREQUENCY ENERGY AND IF NOT INSTALLED AND USED IN ACCORDANCE WITH THE INSTRUCTIONS MAY CAUSE HARMFUL INTERFER ENCE TO RADIO COMMUNICATIONS HOWEVER THERE IS NO GUARANTEE THAT INTERFERENCE WILL NOT OCCUR IN A PARTICULAR INSTALLATION IF THIS EQUIPMENT DOES CAUSE HARMFUL INTERFERENCE TO RADIO OR TELEVISION RECEPTION WHICH CAN BE DETERMINED BY TURNING THE EQUIPMENT OFF AND ON THE USER IS ENCOURAGED TO TRY TO CORRECT THE INTERFERENCE BY ONE OR MORE OF THE FOLLOWING MEASURES REORIENT OR RELOCATE THE RECEIVING ANTENNA INCREASE THE SEPARATION BETWEEN THE EQUIPMENT AND RECEIVER CONNECT THE EQUIPMENT INTO AN OUTLET ON A CIRCUIT DIFFERENT FROM THAT TO WHICH THE RECEIVER IS CONNECTED CONSULT THE DEALER OR AN EXPERIENCED RADIO TV TECHNICIAN FOR HELP CAUTION CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY RESPONSIBLE FOR COMPLIANCE COULD VOID THE USER S AUTHORITY TO OPERATE THE EQUIPMENT THIS CLASS DIGITAL APPARATUS COMPLIES WITH CANADIAN ICES 003 CET APPAREIL NUMERIQUE DE LA CLASSE B EST CONFORME A LA NORME 003 DU CANADA iii KCMU000002 05 30 01 WARNING e TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE e DO NOT INSERT ANY METALLIC OBJECT THROUGH VENTILATIO
6. CONTINUED 5 The KC33W4MM observation camera has a 1 4 20 UNC mounting hole located at the top and the bottom of the camera housing Mount the camera onthe stand by threading the camera onto the mounting bolt Adjust the camera s position and tighten the wing nut to hold the position firmly in place REMINDER Do not aim or point the camera towards the sun or into a strong light 6 The KC33W4MM camera supports both and CS mount lenses The KAOLO4MM lens supplied with the camera is a CS mount lens When using a CS mount lens attach the lens directly on the backfocus ring Backfocus Ring CS MOUNT LENS Backfocus Lock Screw TE OR e Sg Camera Mounting Bracket L gt C Mount Adapter LENS When using a C mount lens attach the C mount adapter to the backfocus ring before attaching the C mount lens 7 KCMU000002 05 30 01 BASIC INSTALLATION CONTINUED 7 KOALO4MM lens supplied with the camera is a DC type fixed focus lens No additional connections are required gt DC Iris Lens Connector If using a DC type auto iris lens plug the cable into the DC lens connector 8 Route the cable from the monitor location to the camera location IMPORTANT Care should be taken when routing the cable from the monitor to the camera Try not to put unnecessary strain on the
7. KC33W4MM 1 3 CCD BLACK AND WHITE PROFESSIONAL OBSERVATION SYSTEM CAMERA ULTRA 200 BW CAMERA USER MANUAL Ultrak Worldwide Support Center Sales 8 Technical Support 1301 Waters Ridge Drive Lewisville TX 75057 800 796 2288 972 353 6400 FAX 972 353 6670 ULT RAIK KCMU000002 05 30 01 ISSUE 1 May 2001 02001 BY ULTRAK ALL RIGHTS RESERVED PRINTED IN USA ULTRAK CORPORATE OFFICE 1301 WATERS RIDGE DRIVE LEWISVILLE TX 75057 972 353 6500 ALL RIGHTS RESERVED NO PART OF THIS PUBLICATION MAY BE REPRODUCED BY ANY MEANS WITHOUT WRITTEN PERMISSION FROM ULTRAK THE INFORMATION IN THIS PUBLICATION IS BELIEVED TO BE ACCURATE IN ALL RESPECTS HOWEVER ULTRAK CANNOT ASSUME RESPONSIBILITY FOR ANY CONSEQUENCES RESULTING FROM THE USE THEREOF THE INFORMATION CONTAINED HEREIN IS SUBJECT TO CHANGE WITHOUT NOTICE REVISIONS OR NEW EDITIONS TO THIS PUBLICATION MAY BE ISSUED TO INCORPORATE SUCH CHANGES USERS OF THIS PRODUCT ARE RESPONSIBLE FOR CHECKING AND COMPLYING WITH ALL FEDERAL STATE AND LOCAL LAWS AND STATUTES CONCERNING THE MONITORING AND RECORDING OF VIDEO AND AUDIO SIGNALS ULTRAK SHALL NOT BE HELD RESPONSIBLE FOR THE USE OF THIS PRODUCT IN VIOLATION OF CURRENT LAWS AND STATUTES i KCMU000002 05 30 01 FCC COMPLIANCE STATEMENT INFORMATION TO THE USER THIS EQUIPMENT HAS BEEN TESTED AND FOUND TO COMPLY WITH THE LIMITS FOR A CLASS B DIGITAL DEVICE PURSUANT TO PART 15 OF THE FC
8. N GRILLS CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER OR BACK NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL EXPLANATION OF GRAPHICAL SYMBOLS The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instruction in the literature accompanying the product iv KCMU000002 05 30 01 IMPORTANT SAFEGUARDS 1 READ INSTRUCTIONS All the safety and operating instructions should be read before the unit is operated 2 RETAIN INSTRUCTIONS The safety and operating instructions should be retained for future reference 3 HEED WARNINGS All warnings on the unit and in the operating instructions should be adhered to 4 FOLLOW INSTRUCTIONS All operating and use instructions should be followed 5 CLEANING Unplug the unit from the outlet before cleaning Do not use liquid cleaners or aerosol cleaners Use a damp cloth for cleaning See cleaning procedures under Maintenance 6 WATER AND MOISTURE Do not use this unit near water or in an unprotect
9. NT BACK FRONT BACK 2 1 Backfocus Ring Used to adjust the focus of the lens 2 Back focus Lock Used to secure the backfocus setting Screw 3 Microphone Gathers sound at the camera location and transmits the sound to the monitor 4 EI Switch Used to turn the electronic iris function ON or OFF 5 Monitor Port Used to connect the cable from the monitor 6 Interphone Port Used to connect optional accessories Up to two alarming devices may be connected to each camera with the purchase of an optional two way connector Motion sensors alarm contacts and two way intercom boxes can also be connected to this port Contact your sales representative to purchase optional accessories 7 Iris Level Control Used to adjust the picture for optimal quality when used with a DC iris lens 3 KCMU000002 05 30 01 CAMERA TOP BOTTOM TOP oll jo 8 8 8 Mounting Hole with 1 4 20 UNC Threads The camera stand screws into this hole CAMERA SIDE 9 DC Iris Lens Port Used to connect a DC iris lens KCMU000002 05 30 01 SECTION 3 INSTALLATION AND ADJUSTMENT CONTENTS OF PACKAGE Installation of the KC33W4MM camera must be performed in accordance with all local and national electrical and mechanical cod
10. ease the camera s depth of field slightly close the manual iris by approximately 5 10 9 KCMU000002 05 30 01 DC TYPE AUTO IRIS LENS INSTALLATION AND ADJUSTMENT OPTIONAL LENS The KC33W4MM camera supports DC autoiris lenses Perform the following steps to install and adjust a DC type auto iris lens 1 Thread the DC iris lens onto the lens mount on the front of the camera If using an Ultrak lens skip to step 3 If using a non Ultrak lens use the manufacturer s instructions to solder the connector supplied with the camera to the lens control wires The pin out and wire color coding for DC type auto iris lenses can vary from one manufacturer to another Plug the connector into the DC iris jack on the side of the camera The connector is keyed can only be inserted into the jack one way Make sure that the EI switch located on the back of the camera is set to OFF Apply power to the camera Adjust the DC type auto iris lens for an optimum picture using the IRIS LEVEL control on the back of the camera 10 KCMU000002 05 30 01 BACKFOCUS ADJUSTMENT Although the camera backfocus was adjusted by the manufacturer prior to shipping it may be necessary to make modifications For best results perform backfocus adjustments at night or while using a 6 or 8 welder s glass in front of the lens The focus of the camera will change slightly if the camera iris was adjusted on a light scene and then changes t
11. ed outdoor installation or any area which is classified as a wet location 7 ACCESSORIES Do not place this unit on an unstable stand tripod bracket or mount The unit may fall causing serious injury to a person and serious damage to the unit Use only with a stand tripod bracket or mount recommended by the manufacturer or sold with the product Any mounting of the unit should follow the manufacturer s instructions and should use a mounting accessory recommended by the manufacturer 8 POWER SOURCES This unit should be operated only from the type of power source indicated on the marking label 9 GROUNDING OR POLARIZATION The power supply supplied with this unit may be equipped with a polarized alternating current line plug a plug having one blade wider than the other This plug will fit into the power outlet only one way This is a safety feature If you are unable to insert the plug fully into the outlet try reversing the plug If the plug should still fail to fit contact your electrician to replace your obsolete outlet Do not defeat the safety purpose of the polarized plug Alternately this unit may be equipped with a 3 wire grounding type plug a plug having a third grounding pin This plug will only fit into a grounding type power outlet This is a safety feature If you are unable to insert the plug into the outlet contact your electrician to replace your obsolete outlet Do not defeat the safety purpose of the grou
12. es Carefully remove the camera and its accessories from the carton and verify that they were not damaged in shipment The contents of the package include 1 2 Black and white CCD camera with CS mount Fixed focus 4mm lens KOALO4MM Connector for DC type auto iris lens C mount adapter Camera stand mount 60 foot camera cable User Manual 5 KCMU000002 05 30 01 BASIC INSTALLATION After unpacking and identifying the package contents perform the following steps to connect the camera to an observation system 1 Locate the following items which may be needed during installation but are NOT supplied with the KC33W4MM camera e Observation monitor e Welder s glass e Mounting hardware e Tools 2 Select a suitable location for the camera noting that the supplied camera cable is 60 feet long A IMPORTANT If installing the camera more than 60 feet from the monitor contact your sales representative to purchase longer cables 3 Test each camera and cable at the monitor location prior to mounting the cameras and running cables 4 Use suitable fastener and necessary tools to mount the camera stand to a structural object such as a wall stud shelf or ceiling rafter that can support the weight of the camera and mount A IMPORTANT The maximum recommended load of the mounting bracket is 11 Ibs 5kg 6 KCMU000002 05 30 01 BASIC INSTALLATION
13. he camera Remove the audio jumper using needle nose pliers Replace the jumper on the center pin and the OFF pin as illustrated Move the jumper from the ON and center position to the OFF and center position to disable the audio from the camera to the observation monitor 12 KCMU000002 05 30 01 AUDIO DEFEAT ADJUSTMENT CONTINUED If an intercom station is used Disconnect the microphone connector by grasping the black and white wire located next to the connector and pulling The connector should release with minimum effort Coil the microphone cable and cover the connector with electrical tape to avoid possible electrical shorts Leave the jumper in the ON and center position to use the audio from the intercom station to the observation monitor Disconnect the microphone cable to disable audio from the camera Microphone cable and connector black amp white 7 Replace the cover and cover screws 8 Reconnect the cable s to the back of the camera 9 Turn the monitors main power switch 13 KCMU000002 05 30 01 SECTION 4 TROUBLESHOOTING AND MAINTENANCE TROUBLESHOOTING If you experience difficulties operating your camera refer to the following Ifthe guidelines do not enable you to solve the problem contact an authorized technician PROBLEM Is the system plugged in Is the main power switch on the No Power observation monitor ON Does the outlet have power Is the mon
14. itor turned ON Power but No Picture Is anything blocking the camera lens No Audio or Video e 5 the camera cable firmly plugged into the monitor and camera e Are all connections firmly in place on the back of the monitor and at all accessories e Ifthe monitor offers quad display No Audio and is in quad display mode is the flashing square in the correct quadrant the volume control set at an appropriate level Video but e Power down the system for one No Control minute then turn the system ON Squealing Noise at The camera is too close to the the Monitor ona monitor and or the volume control Camera on the monitor is too high 14 KCMU000002 05 30 01 Following the preventive maintenance schedule allows detection and correction of minor faults before they become serious and cause eguipment failure Every three months perform the following 1 Inspect all connecting cables for deterioration or other damage 2 Clean components with a clean damp cloth 3 Verify that all mounting hardware is secure 15 KCMU000002 05 30 01 SPECIFICATIONS Power Source 15V dc from monitor Power Consumption 2W max Image Sensor 1 3 interline transfer CCD Picture Element 512H x 492V Image Sensor Area 4 9H x 3 7V mm Unit Cell Size 9 6um x 7 5um Resolution gt 380 TV lines Minimum Illumination 0 1 lux F3 8
15. nding type plug KCMU000002 05 30 01 IMPORTANT SAFEGUARDS 10 11 12 13 14 15 16 17 POWER CORD PROTECTION Power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them paying particular attention to cords and plugs convenience receptacles and the point where they exit from the appliance Overloading Do not overload outlets and extension cords as this can result in a risk of fire or electric shock Object and Liguid Entry Never push objects of any kind into this unit through openings as they may touch dangerous voltage points or short out parts that could result in a fire or electric shock Never spill liguid of any kind on the unit Servicing Do not attempt to service this unit yourself as opening or removing covers may expose you to dangerous voltage or other hazards Refer all servicing to qualified service personnel Damage Requiring Service Unplug the unit from the outlet and refer servicing to qualified service personnel under the following conditions a When the power supply cord or plug is damaged b If liquid has been spilled or objects have fallen into the unit If the unit has been exposed to rain or water d If the unit does not operate normally by following the operating instructions Adjust only those controls that are covered by the operating instructions as an improper adjustment of other c
16. o a dark scene However the camera will remain in focus ifthe iris was focused on a dark scene and the scene lightens To make backfocus adjustments perform the following 1 Mount the lens on the camera and apply power 2 Open the camera iris by turning the lens level control counterclockwise 3 Ifa picture is visible focus on the scene Open the lens as wide as possible by placing a welder s glass in front of the lens 4 When the iris is open to the widest point readjust the focus for a clear picture If a clear picture is not visible set the focus ring to mid range Loosen the backfocus lock screw Adjust the backfocus ring for a clear picture Tighten the backfocus screw lock Fine tune the focus with the focus ring on the lens Remove the welder s glass from in front of the lens 10 Adjust the level control of the lens for the best picture guality 11 KCMU000002 05 30 01 AUDIO DEFEAT ADJUSTMENT It may be necessary to disable the audio from the camera to comply with some state and local laws and regulations To disable audio perform the following 1 Turn the monitor s main power switch OFF Remove the camera from the camera stand Disconnect the cable s from the back of the camera Remove the two screws on top of the camera Remove the top half of the camera case If an intercom station is not used Locate the audio disable jumper on the right back portion of t
17. ontrols may result in damage and will often require extensive work by a qualified technician to restore the unit to its normal operation Ifthe unit has been dropped or the enclosure has been damaged When the unit exhibits a distinct change in performance this indicates a need for service Replacement Parts When replacement parts are required be sure the service technician has used replacement parts specified by the manufacturer or have the same characteristics as the original part Unauthorized substitutions may result in fire electric shock or other hazards Safety Check Upon completion of any service repairs to this unit ask the service technician to perform safety checks to determine that the unit is in proper operating condition Lightning For added protection of this unit during a lightning storm or when it is left unattended and unused for long periods of time unplug it from the wall outlet and disconnect the cable system This will prevent damage to the unit due to lightning and power line surges vi KCMU000002 05 30 01 TABLE OF CONTENTS SECTION 1 1 PRODUCT 2 1 FEATURES ac d a i 1 SECTION 2 CONTROLS AND 3 CAMERA 2221 3 CAMERA TOP
Download Pdf Manuals
Related Search
Related Contents
High Performance Computing Cluster Quick Reference User Guide Avaya 413X/414X User Guide KRAMPE HAREX TWINMIX DE 60-1N Program Release Information CSES ID los proyectos hacen los objetos eternos, las modas los Extinguisher Manual Nobo Shark Flipchart Easel - Retail Pack IPG IPS Consumer AIO Color 2 Acer G330 User's Manual Copyright © All rights reserved.
Failed to retrieve file