1. 14 How to change route sensor parameters 15 How to recognise that measurement has been done 16 How to repeat the 16 HOW lo See measured 17 How to upload data from instrument to PC 18 Preparation of 0052000 software for data 18 Connection of the instrument to PC and route 20 How to connect vibration sensor 23 Do first simple measurement 24 Measure your TIrst Spectrum excusa ce bn cus Ee Dacos a 25 How to create DDS2000 tree 28 Preparation DDS2000 ex pt oe A ute pt ttes se Pit 28 New tree CreallOl Icosueiuene2 50e add ant est ooo ned Dod ceed carn ae 28 creating new Tree sc asser ood ed doc ossis eo eod eet onis eoe ped ei set edet 30 455 UU LL 32 PIOW al Cal Mere T
2. 8 ADASH Ltd Czech republic tel 420 596 232 670 fax 420 596 232 671 email info adash cz For next technical and contact information visit www adash net www adash cz Adash Ltd Adash 4300 VAS Quick Start 5 Click the New button and in new window dialog enter new name of tree Hame New Tree bmp es Database DDS Note Cancel lr Extended 6 In the Tree Item window click OK and the new tree is done Also the parent item with the same name is created New tree EI T J id SEESESESESESES E TUER RAT i D 3 pe m a Panl SMe ee Sey mm ga eri ADASH Ltd Czech republic tel 420 596 232 670 fax 420 596 232 671 email info adash cz For next technical and contact information visit www adash net www adash cz Adash Ltd Adash 4300 Quick Start Creating new tree items 7 Click the Right button of your mouse on an item in a tree structure and the following menu appears IL rem em Sl 1201 Tose SUB tree Shaw pem ata celis Gose aba els Draw EIC Dake Reduction 8 Select Add ltem and a new window for creation of the item appears Tree Item E ADASH Ltd Czech republic tel 420 596 232 670 fax 420 596 232 671 email info adash cz For next technical and contact information visit www ada
3. Switch off the analyser by pressing the combination of the START ESC keys Release the screw of the supply cells cover Replace the discharged cells by charged ones pay attention to the correct polarity of each cell Fix the cover and tighten the screw Switch on the analyser by pressing the START key Activate the Instrument Info screen from the Main Menu and check the condition of the installed batteries Indication of Weak Batteries re chargeables When you select the Instrument info from main menu then information on the current condition of the batteries appears While the instrument is switched on the battery condition is checked every 30 sec 1 When a warning low battery level is detected insufficient to enable correct and safe work with instrument the yellow ERR light is on on the top of keyboard Finish your current measurement and then change the batteries 2 When the alert low battery level is detected all three lights on the top of the keyboard blink three times and instrument switches itself off You have to change the batteries immediately If the instrument switches itself off after switch on then you also have to change the batteries immediately Attention When the instrument is switched off for several minutes weak batteries can be regenerated and for a limited time can seem to be in good condition Do not try repeatedly switching on when the instrument itself switches off immediately
4. View Forma Displayed Signal Type Cascade specification Info Draw Band Graph View Reference Spectrum Records Selection Print Save to Clipboard as Bitmap k Ld k ADASH Ltd Czech republic tel 420 596 232 670 fax 420 596 232 671 email info adash cz For next technical and contact information visit www adash net www adash cz
5. HERSURE LOWER DISP OFF 9 Use Right Left arrows for cursor cross movement You will see the frequency and amplitude values changing at the top of the screen e g 524 Hz and amplitude 0 23 g on Figure CH1 SPEC LIN HAG Cursor A H BB 320B Hz VY 8 88 48 238 9 Cursor 52745 68 29 1 CH1 SPEC LIH HAG Cursor Dynamic measurements A H B8BH 328B Hz V B HB H 28 1 Lursa r 525 8 23 z UPPER DISP CH1 DISP UHIT SPEC Y AXIS LIN HAG Y RANGE AUTO HEASURE LOWER DISP OFF ADASH Ltd Czech republic tel 420 596 232 670 fax 420 596 232 671 email info adash cz For next technical and contact information visit www adash net www adash cz Adash Ltd Adash 4300 VAS Quick Start How to create DDS2000 tree item Preparation of DDS2000 1 Run DDS2000 software system 2 Select Database Select and open item in main menu The list of databases appears 3 Select the database you require for illustration only this manual refers to the DDS2000 database which includes demo data and it is installed with 0052000 automatically and click to Open database button this database can be opened automatically with DDS2000 start then this button is not active grey in this case only close Database List window CT xl Duft OS 2000 pel deal ID 13543221 3075 New tree creation 4 Select Trees item in main menu The list of all trees in this database appears aA m Dara 2 DE
6. User Manual a wr dasht Vibration Analyser E Adash 4300 VA3 Quick Start Ref 24112004 RS ADASH Ltd Czech republic tel 420 596 232 670 fax 420 596 232 671 email info adash cz For next technical and contact information visit www adash net www adash cz Adash Ltd Adash 4300 Quick Start Contents Before Switching On the Analyser Br PEN RCM USE 3 Procedure of Supply Cells 4 Indication of Weak Batteries 4 14 e RR 5 HOW TO SWITCH insir menton OIT iios Desde se une 6 How to select and to run menu item ssassnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn nnmnnn mnnn 7 Location of Keys and Lights on the Instrument Keyboard 7 How to select and to modify setting screen item eese esses 8 How to download a route from the computer to the instrument 9 Route preparation in DDS 2000 9 Connection of the instrument to PC and route download 12 How to measure in route mode
7. PSA Sensitivity 1 8 B8 mU g Yes START No ESC ADASH Ltd Czech republic tel 420 596 232 670 fax 420 596 232 671 email info adash cz For next technical and contact information visit www adash net www adash cz Adash Ltd Adash 4300 Quick Start 4 By Up Down arrows select required machine and open it by pushing Right arrow The list of measurement points appears DEMO Route YAS Data Factory Fans Fan 2 AS30868 UAS Data Factory Fans Fan 1 AS30868 UAS DatafsFactory Fans Fan 2 A4300 UAS Data Factory U Pumps PSA 5 By Up Down arrows select required point connect your sensor to the appropriate location and by pushing START run the measurements which are defined for this point The list of all measurements is displayed and the pointer indicates the current measurement ASS08 YAS Data Factory Fans Fan 2 BERRIHG RHS 6 When all measurements are finished the individual results appear step by step How to change route sensor parameters Push Setup in some route display and the Route sensor menu appears Now select required item and change the set value e g sensitivity from 100 mV g to 50 mV g Route sensor AS388 Un3 Data Factary Fans Fan 2 Route sensor CHANNEL CH1 OFF ACC g TUV 188nU g Setup 8 CHANNEL CH1 ADASH Ltd Czech republic tel 420 596 232 670 fax 420 596 232 671 email info adash cz For next technical and contact information visit www ada
8. RHS H1 18 11 21 nm 5 4 Return by pushing ESC or Left arrow ADASH Ltd Czech republic tel 420 596 232 670 fax 420 596 232 671 email info adash cz For next technical and contact information visit www adash net www adash cz Adash Ltd Adash 4300 VAS Quick Start How to upload data from instrument to PC Preparation of DDS2000 software for data upload 1 Run the DDS2000 software 2 Select Database Select and Open item in main menu The list of databases appears Dua abe Let 18 ADASH Ltd Czech republic tel 420 596 232 670 fax 420 596 232 671 email info adash cz For next technical and contact information visit www adash net www adash cz Adash Ltd Adash 4300 VAS Quick Start 3 Select the database you require and click the Open database button 4 Select Trees item in main menu The list of all available trees in this database appears AAT UT Dara 5 Select the required tree and click the Open Tree button The new window with tree structure appears ADASH Ltd Czech republic tel 420 596 232 670 fax 420 596 232 671 email info adash cz For next technical and contact information visit www adash net www adash cz Adash Ltd Adash 4300 VAS Quick Start 6 Select Tools Connect Instrument A4300 item in main menu A new empty transfer window appears mier periere egit fhe gm cm Wi aA 8 Connection of the
9. You may cause instrument failure and data in memory can be corrupted 4 ADASH Ltd Czech republic tel 420 596 232 670 fax 420 596 232 671 email info adash cz For next technical and contact information visit www adash net www adash cz Adash Ltd Adash 4300 Quick Start References This user manual helps you to get familiar with basic features of Adash 4300 instrument The Vibration Analyser Adash 4300 VA3 User manual is an integral part of this manual References 1 Vibration Analyser Adash 4300 VA3 User manual The basic manual is often mentioned in this one as see 1 We recommend reading of introductory chapters References and Terminology in the basic user manual 1 at first This manual is registered in the list of references as the 2 item 5 ADASH Ltd Czech republic tel 420 596 232 670 fax 420 596 232 671 email info adash cz For next technical and contact information visit www adash net www adash cz Adash Ltd Adash 4300 VAS Quick Start How to switch instrument on off 1 Push the START button and the analyser switches on The Logo and the base analyser information appear The battery condition is checked too The main menu appears in a few seconds 24 11 2005 12 13 41 Datacollector PRO HRIH Dekault pedir esent Datecollector route Henory management InsErument setup Instrument into Firewire Press and hold ESC STARBT to switch off 2 Pus
10. depending upon whether you wish to add an overall trend measurement or a new spectrum measurement IT EIE Created 2003 11 28 5 0 Hea Type bim m3 rera Cinta 14 10 2000 11 26 58 ikanra mee 27 10 206013 ean condis e bo Pon parameter If you select Static value there are several standard sub types which hare pre defined for use the VAS such as ISO velocity These sub types will automatically set the correct measurement unit required If you select ABS Spec or Time the Meas conditions button will become active Click on this button and a further set up screen appears where you can set up frequency range number of lines number of averages etc for spectrum measurement or the sample time and frequency window for time waveforms are defined 10 Now click to button OK and the new data cell will be created For a more detailed description read in DDS2000 guide siano nl n Hs To ET Fuse d J p s E 1 cb eub rb L ILLI LEE a Sole Heo lee ADASH Ltd Czech republic tel 420 596 232 670 fax 420 596 232 671 email info adash cz For next technical and contact information visit www adash net www adash cz Adash Ltd Adash 4300 VAS Quick Start How to look at data Preparation of DDS2000 1 Run DDS2000 softw
11. instrument to PC and route upload 1 Switch on the instrument the main menu appears 01 10 2002 08 08 32 HAIN HEHU Default measurements Datacollector route Hemory management Instrument setup Instrument info ADASH Ltd Czech republic tel 420 596 232 670 fax 420 596 232 671 email info adash cz For next technical and contact information visit www adash net www adash cz Adash Ltd Adash 4300 VAS Quick Start 2 Connect the instrument via serial cable which you receive with instrument On the instrument use the connector RS232 on the bottom On the computer use any free serial port 3 In transfer window A4300 push Find button ATTENTION the instrument has to be in main menu When the connection is created the Instrument found report appears In the case of problems check the correct selection of COM port first and correct cable connection in both side Transfer to 44300 Transf fram 44300 Store To Database Instrument found Close ADASH Ltd Czech republic tel 420 596 232 670 fax 420 596 232 671 email info adash cz For next technical and contact information visit www adash net www adash cz Adash Ltd Adash 4300 VAS Quick Start 4 In transfer window A4300 VA3 click Transfer from 4300 button Select your route from the list of routes in the instrument Click the OK button now the route is uploaded to the computer ascen n Hi T _ _ S aaa 5 Cli
12. it is installed with DDS2000 automatically and click to Open database button this database can be opened automatically with DDS2000 start then this button is not active grey in this case only close Database List window 9 ADASH Ltd Czech republic tel 420 596 232 670 fax 420 596 232 671 email info adash cz For next technical and contact information visit www adash net www adash cz Adash Ltd Adash 4300 VAS Quick Start 4 Select Trees item in main menu The list of all trees in this database appears AA Data 5 Select the tree you require for example the A4300_VA3 Data tree and click the Open tree button A new window with the tree structure appears By double clicking again you can open the next tree paths ADASH Ltd Czech republic tel 420 596 232 670 fax 420 596 232 671 email info adash cz For next technical and contact information visit www adash net www adash cz Adash Ltd Adash 4300 VAS Quick Start 6 Select Tools Connect Instrument A4300 item in main menu A new empty transfer window for data with the instrument appears Bs E E impp ctp o e 7 In the window on the right containing the data tree open the tree to show those items which you want to measure in your route By drag and drop move these items to the A4300 window on the left of the screen In this window the list of all measurement points appears By double click or Enter b
13. routes in the instrument appears instrument can include max 30 routes Click the New route button and enter the name Click the OK button now the route is downloaded to the instrument In case of success the OK report appears ST x 5 Disconnect the cable and now you can take route measurements with the A4300 VA3 ADASH Ltd Czech republic tel 420 596 232 670 fax 420 596 232 671 email info adash cz For next technical and contact information visit www adash net www adash cz Adash Ltd Adash 4300 Quick Start How to measure in route mode 1 Select Datacollector route item and open it The list of routes in instrument memory appears on the display e g DEMO Route 61 18 2682 12 31 54 Datacollector route HAIN HEHU Analyser Default measurements Datacollector route Hemory management Route Instrument setup Instrument info 2 Select by arrows the required route and open it by pushing Right arrow The information about default route sensor set in the instrument for a route appears Datacollector route Default route sensor Channel CH1 ICP ON DEHO Route Sensor ACC Unit g Sensitivity 168 86mU qg Yes START No ESC 3 Push START and the list of machines in the route appears DEMO Route Default route sensor Channel CH1 ICP ON ASSH8 UAS Data Factoryu Fans Fan 1 Sensor ACC A4300 VAS DatafsFactory Fans Fan 2 Unit g A4300 YAS Data Factory U Pumps
14. 96 232 670 fax 420 596 232 671 email info adash cz For next technical and contact information visit www adash net www adash cz Adash Ltd Adash 4300 Quick Start How to select and to modify setting screen item 1 Use the arrow keys up down for selection of screen item 2 Push Right arrow or ENTER and list of possible values will be displayed At some places you may be required to manually enter a value or text 3 Select or enter value 4 Push Left arrow or ESC for return back All defined values are stored in a buffer and will only be used until you switch off of instrument If you wish to make a permanent change you must save it 5 Push Save and all configuration data of instrument is saved to permanent memory Route sensor Route sensor iii CH1 CHRHHEL CH1 ICP SENSOR ACC UHIT g 188mU g SENSIT 188mU g RANGE AUTO 8 ADASH Ltd Czech republic tel 420 596 232 670 fax 420 596 232 671 email info adash cz For next technical and contact information visit www adash net www adash cz Adash Ltd Adash 4300 VAS Quick Start How to download a route from the computer to the instrument Route preparation in DDS 2000 software 1 Run DDS2000 software system 2 Select Database Select and open item in main menu The list of databases appears 3 Select the database you require for illustration only this manual refers to the DDS2000 database which includes demo data and
15. R 34 Prepalallon DS2Z000 ETE 34 m 36 aD e M 37 2 ADASH Ltd Czech republic tel 420 596 232 670 fax 420 596 232 671 email info adash cz For next technical and contact information visit www adash net www adash cz Adash Ltd Adash 4300 VAS Quick Start Before Switching On the Analyser 1 Connect into the ICP input only ICP powered sensor AC voltage max 12 V peak peak DC voltage max 24 V If you are not sure contact your dealer or directly our website 2 Never connect the analyser to a line voltage 230 V 110 V 3 Only use batteries with a nominal voltage of max 1 5 V Warning Be careful of battery orientation Fig Correct polarity of the supply cells 1 To supply the analyser the following can be used batteries with a nominal voltage of 1 2 V alkaline cells not a different type with a nominal voltage of 1 5 V 2 Do not combine various types of supply cells always mount four identical cells 3 Check the polarity of the mounted cells carefully By inversing polarity of one cell the supply cells would be damaged 3 ADASH Ltd Czech republic tel 420 596 232 670 fax 420 596 232 671 email info adash cz For next technical and contact information visit www adash net www adash cz Adash Ltd Adash 4300 Quick Start Procedure of Supply Cells Replacement
16. agement Instrument setup Instrument info 5 2 Select Dynamic measurements item and push the Right arrow The setting screen appears Dynamic measurements UPPER Eu DISP UHIT g EURLURTIUH TIHE Y RAIS REAL Y RANGE AUTO HERSURE Analyser Inputs and sensors Trigger inputs Wide band values Dun measur setup Dynamic measurements Heasurements memory LOWER DISP OFF 3 Different data evaluation can be set e g Time signal TIME from acceleration g from channel 1 Select EVALUATION item push arrow Right and select SPEC Dynamic measurements Dynamic measurements UPPER DISP CH1 DISP UNIT g Se TIHE Y RaAIS RERL Y RRHGE AUTO MEASURE UPPER DISP CH1 DISP UHIT g EURLURTIUH TIHE Y RAIS REAL Y RANGE AUTO HEASURE LOWER DISP OFF LOWER DISP OFF 25 ADASH Ltd Czech republic tel 420 596 232 670 fax 420 596 232 671 email info adash cz For next technical and contact information visit www adash net www adash cz Adash Ltd Adash 4300 Quick Start 4 Push Setup button the setting screen Spectrum appears Dynamic measurements UPPER DISP CH1 DISP UHIT g SPEC Y AATS LIH H AG T RAHGE AUTO HERSURE LOWER DISP OFF spectrum Pee 1B80Hz F5 256Hz LIHES 188 4a 1 8Hz WINDOW HRHHIHG TRIGGER FREERUH TRIG H DE SINGLE AVERAGING OFF RUER HHB 2 5 Select BASE BAND item and set frequency range e g 3200 Hz spectrum T
17. are system 2 Select Database Select and open item in main menu The list of databases appears 3 Select the database you require for illustration only this manual refers to the DDS2000 database which includes demo data and is installed with DDS2000 automatically and click to Open database button this database can be opened automatically with DDS2000 start then this button is not active grey in this case only close Database List window Databaseliat 08 Duft OS 2000 ID 13543221 3075 4 Select Trees item in main menu The list of all trees in this database appears Trees 4 mn EES z nn Dua 34 ADASH Ltd Czech republic tel 420 596 232 670 fax 420 596 232 671 email info adash cz For next technical and contact information visit www adash net www adash cz Adash Ltd Adash 4300 VAS Quick Start 5 Select the tree you require for example the Demo Data tree and click the Open tree button A new window with the tree structure appears Pn E p m m ees ADASH Ltd Czech republic tel 420 596 232 670 fax 420 596 232 671 email info adash cz For next technical and contact information visit www adash net www adash cz Adash Ltd Adash 4300 VAS Quick Start Fast view 1 Highlight one item tree item or data cell 2 Click the in Tool bar or Space button on keyboard The related data appears text inf
18. ck to the Store To Database button All measured data will be saved to relevant data cells IMPORTANT IF YOU DO NOT PRESS STORE TO DATABASE BUT SIMPLY CLOSE THE SCREEN THE DATA WILL NOT BE STORED TO THE DATABASE AND YOU MUST REPEAT THE UNLOADING PROCESS 6 Disconnect the cable and now you can make next data acquisition in DDS2000 software 22 ADASH Ltd Czech republic tel 420 596 232 670 fax 420 596 232 671 email info adash cz For next technical and contact information visit www adash net www adash cz Adash Ltd Adash 4300 VAS Quick Start How to connect vibration sensor 1 The analyser has a connector on its upper side for the connection of the vibration sensor with the ICP supply Connected sensor to this input is labelled CH1 channel 1 in all menus 2 The connector on left side is also determined for the connection of the vibration sensor with the ICP supply Connected sensor to this input is labelled CH2 channel 2 in all menus 3 The default would be to connect sensor via supplied cable to upper input CH1 All the following descriptions will be assume this configuration 23 ADASH Ltd Czech republic tel 420 596 232 670 fax 420 596 232 671 email info adash cz For next technical and contact information visit www adash net www adash cz Adash Ltd Adash 4300 Quick Start Do first simple measurement 1 Select by arrows the Default Measurements item in main menu Push Right arrow The
19. ee TRH F5 256Hz LINES 188 a 1 8Hz WINDOW HRHHIHU TRIGGER FREERUH TRIG H DE SINGLE AVERAGING OFF RUER HHB 2 6 Select and set LINES item e g 800 spectrum lines o spectrum BASE BAND 3200Hz f5 8192Hz LIHES 188 4 32Hz WIHDOW HRHHIHG TRIGGER FREERUH TRIG HODE SINGLE AVERAGING OFF RUER HHB 2 o spectrum BASE BAND 180H Hz fs 256 LIHES 188 4a 1 8Hz UIHNDUM HRHHIHU TRIGGER FREERUH TRIG H DE SINGLE AVERAGING OFF RUER HHB 2 spectrum BASE BAND 328B8Hz f5 81 LIHES 188 4 32Hz UIHDUU HRHHIHG TRIGGER FREERUH TRIG H DE SINGLE AVERAGING OFF RUER HHB 2 7 Escape from setting screen by Left arrow to the Dynamic measurements screen spectrum BASE BAND 3288H2 f5 8192Hz LIHES SBB8 a 45 B8Hz UIHDUM HRHHIHG TRIGGER FREERUH TRIG H DE SIHGLE AVERAGING OFF RUER HHB 2 Dynamic measurements UPPER DISP CH1 DISP UHIT g AGIRI SPEC Y RAIS LIN HAG T RAHGE AUTO HERSURE LOWER DISP OFF ADASH Ltd Czech republic tel 420 596 232 670 fax 420 596 232 671 email info adash cz For next technical and contact information visit www adash net www adash cz Adash Ltd Adash 4300 Quick Start 8 Push STAHT button for measurement The measured spectrum appears Dynamic measurements CH1 SPEC LIN HAG Cursor XK 8 88 32080 Hz V 8 808 8 28 g roe e Cursor 0 08 40 08 1 1 DISP UNIT g SPEC Y AATS Y RANGE AUTO
20. h and hold the ESC START buttons and the analyser switches off 3 If the disc logo or A4300 Loader title appears after switching on then the instrument is waiting for upload of firmware Individual steps are described in 1 Instrument Firmware Update chapter gt The floppy disk logo or A4300 Loader title on the display means a firmware failure a300 WAR 4200 6 ADASH Ltd Czech republic tel 420 596 232 670 fax 420 596 232 671 email info adash cz For next technical and contact information visit www adash net www adash cz Adash Ltd Adash 4300 VAS Quick Start How to select and to run menu item 1 Use the arrow keys up down for selection of menu item 2 Push the Right arrow ENTER or START for function run 3 Push the Left arrow or ESC for return back Instrument setup 01 10 2002 88 13 83 Heas param HAIN HEHU Route sensor Display brightness Display contrast Analyser Actual date Default measurements Actual time Datacollector route Language version Memory management Instrument setup Instrument info Location of Keys and Lights on the Instrument Keyboard ERR STAT ERR STAT meas e meas 9 SPACE DEF SPACE ABC Cursor PgUp Copy Cursor PgUp 1 2 3 2 3 MNO MNO PgDn PgDn 6 6 5 TUV 5 TUV Delete Setup Delete Setup 7 8 7 8 A keypad design version 1 B keypad design version 2 7 ADASH Ltd Czech republic tel 420 5
21. list of possible measurements appears H1 18 2882 68 38 21 MATH HEHU Default measurements Analyser 150 16 1666H2 Default measurements Bearing 5 16kHz Datacollector route L Bearing 8 5 16kHz Memory management Heasurements memory Instrument setup Instrument info 2 Push Right arrow or START for running of ISO 10 1000 measurement RMS velocity in 10 1000Hz frequency band 3 The bar at the bottom of the screen indicates ICP accelerometer power is switched on the VA3 is waiting for stability of the signal The Meas light on the keyboard top lights yellow and indicates preparation of measurement 4 When the signal is stable the Meas lights green and the measurement is running 5 Measured value is continuously displayed CH1 8 1888Hz RHS 6 81 mm 5 6 Finish the measurement by pushing and holding the ESC button ADASH Ltd Czech republic tel 420 596 232 670 fax 420 596 232 671 email info adash cz For next technical and contact information visit www adash net www adash cz Adash Ltd Adash 4300 Quick Start Measure vour first spectrum 1 Select by arrows the Analyser item in main menu Push the Right arrow The list of possible functions appears H1 18 2882 08 08 32 Analyser MENU Inputs and sensors Trigger inputs Wide band values Dyn measur setup Dynamic measurements Heasurements memory Default measurements Datacollector route Memory man
22. ormation graph value bitmap EE Complex Spektrum Order Analysis ES Vel Time Signal ES tec Time Sigmal EE Vel Spectrum 3 Change the active item by mouse or arrows ADASH Ltd Czech republic tel 420 596 232 670 fax 420 596 232 671 email info adash cz For next technical and contact information visit www adash net www adash cz Adash Ltd Adash 4300 VA3 Quick Start Graph chart 1 Highlight required data cell by mouse By double click open new window with graphics representation of data The base graphics data types are Trend Denn Ostas IEO Tried Spectrum Dest 14 1 2 1999 Baa AALOL Time signal Tine Signal 1230 Rul Order analysis ADASH Ltd Czech republic tel 420 596 232 670 fax 420 596 232 671 email info adash cz For next technical and contact information visit www adash net www adash cz Adash Ltd Adash 4300 VAS Quick Start 2 When you open several data windows and then use Tiles function the similar window organisation appears Number of graphs is not limited 3 Move the mouse cursor to any graph Click the Right button The menu with all possible functions appears See DDS2000 manual for detailed description of each function Cursors 5 axis Y axis Grid zoom Move Marks Quantity Derivation Integration view Unik
23. sh net www adash cz Adash Ltd Adash 4300 Quick Start How to recognise that measurement has been done A measurement which is not yet done does not show a time stamp in the list e g ISO is done Bearing is not IS0 RHS H1 1H8 15 2 BERRIHG RHS How to repeat the measurement It is an important feature of the that all measurements associated with one measurement point are measured in one go It is also possible to make each individual measurement alone The new measurement erases the old value 1 Select required point and push Right arrow pushing START starts series measurement The list of measurements appears ASSO YAS Data Factory Fans Fan 2 IS0 RHS H1 18 14 22 BERRIHG RHS OZO 2 Select required measurement and push START CH1 5888 16 088Hz RHS BERRIHG RHS IS0 RHS H1 18 15 2 63 q 3 Push ESC or Left arrow for return ADASH Ltd Czech republic tel 420 596 232 670 fax 420 596 232 671 email info adash cz For next technical and contact information visit www adash net www adash cz Adash Ltd Adash 4300 Quick Start How to see measured data 1 In the list of measurements select required item 2 If the time stamp is not displayed then no data exists 3 Where a time stamp is displayed open a new screen by pressing the Right arrow where the measured value or graph is displayed CH1 8 1888Hz RHS IS0 RHS H1 18 11 20 B 1 BERRIHG
24. sh net www adash cz Adash Ltd Adash 4300 VAS Quick Start 9 Enter a name for the item select the bitmap option and click OK The new item is created under its parent active item By repeating this process you can develop a complete tree with required structure The number of levels is not limited You can simply create new structure by means of copying existing items either from another tree or even from another database For a detailed description please refer to the DDS2000 guide ADASH Ltd Czech republic tel 420 596 232 670 fax 420 596 232 671 email info adash cz For next technical and contact information visit www adash net www adash cz Adash Ltd Adash 4300 Quick Start Data cell creation 10 The tree structure is used to define the logical layout of the database and allows you to manage and define a structure Measurements can take place at any level in the tree Measured data are saved into data cells Open the window with the tree Move your mouse over the item into which you want save data Click Right button of mouse and the next menu appears b fo s ADASH Ltd Czech republic tel 420 596 232 670 fax 420 596 232 671 email info adash cz For next technical and contact information visit www adash net www adash cz Adash Ltd Adash 4300 VAS Quick Start 9 Enter new name select instrument type A4300 select Data type Static value or ABS spec or Time
25. utton it is possible to open each item in the list to show all the sub items This is very similar to the DDS2000 tree ADASH Ltd Czech republic tel 420 596 232 670 fax 420 596 232 671 email info adash cz For next technical and contact information visit www adash net www adash cz Adash Ltd Adash 4300 VAS Quick Start Connection of the instrument to PC and route download 1 Switch on the instrument the main menu appears 01 10 2002 08 08 32 HAIN Default measurements Datacollector route Hemory management Instrument setup Instrument info 2 Connect the instrument via serial cable which you receive with instrument On the instrument use the connector RS232 on the bottom On the computer use any free serial port 3 In transfer window 4300 push Find button ATTENTION the instrument has to be in main When the connection is created the Instrument found report appears In the case of problems check the correct selection of COM port first and correct cable connection in both side Transfer to 44400 Transf from 44300 Store To Database Instrument found Close ADASH Ltd Czech republic tel 420 596 232 670 fax 420 596 232 671 email info adash cz For next technical and contact information visit www adash net www adash cz Adash Ltd Adash 4300 VAS Quick Start 4 In transfer window A4300 VA3 click Transfer to 4300 button A new window with a list of