Home

E and ES Series Enclosures Installation Instructions

image

Contents

1. 5 16 closed wrench from inside of the enclosure ANCHOR MOUNTING THRU HOLE E SERIES The middle 75 dia thru holes are for securing the enclosure to the floor These holes will accept a standard concrete anchor if desired the Seismic Anchor Kit AK101 is suggested CASTER MOUNTING E SERIES The four inside holes in each corner are threaded 1 2 13 thds to accept the casters Be sure to thread the caster into the bottom of the cabinet until it is firmly seated 4 Adjustable Swivel Casters Counter clockwise rotation will adjust the leveling glide up gt Clockwise rotation will adjust 75 Thru holes the leveling glide down CASTER AND LEVELER MOUNTING ES SERIES A CAUTION install casters or levelers the enclosure must be tipped onto its side The enclosure can be very heavy several people will be required in this process Please practice safe lifting techniques DO NOT lay the enclosure on its front or back this may damage the door hinges Removing doors and sides will help reduce the weight of the enclosure gt Before tipping remove the side panels to prevent damage to the locks and latches 1 To install casters the enclosure must first be tipped over onto laid on its side 2 Pass a plate caster over four threaded studs located in one of the recessed areas in the bottom of the enclosure 3 Thread 1 5 16 18 hex nut onto each stud and tighten with a 1 2 socket or nut d
2. 49 C B Twist Lock Plug L5 20P 5 20R Receptacle 49 Circuit Breaker 5 20P Plug 5 20R Receptacle 48 Two banks of 12 NEMA 5 20R Receptacles L5 30P Plug 25 Circuit Breaker 5 15P Plug 5 15R Receptacle for use with 48 and 60 H enclosures Measure your verical EIA rails front o back for shelf Shelf mounting tabs are adjust able beyond the shelf surface depth for maximum flexibly Vist our web site at www werackyourword com for a complete ist of available accessories NOT RESPONSIBLE FOR IYPOGRAPHICAL ERRORS 26 CONFIGURED ENCLOSURES ANY WAY YOU WANE SHIPPED WIGHIN 24 48 HOURS READY CHOOSE A STANDARD ENCLOSURE PICK THE GREAT LAKES ACCESSORIES YOU NEED SET WE LL CONFIGURE THE ENCLOSURE EXACTLY HOW YOU SPECIFY EVERYTHING IS WRAPPED IN ONE ENCLOSURE GO CONFIGURED ENCLOSURE WILL SHIP WITHIN 24 48 HOURS OF RECEIPT OF ORDER 27 GREAT LAKES 4 CASERCABINET MA Thank you for your business ama ove ETSI Associate Member
3. load the heaviest equipment first at the bottom of the E and ES Enclosure and load the lighter units at the top OPERATING DOOR HANDLE ESERIES The door swing handles have been installed at the manufacturer No additional assembly is required To operate the swing handle lift up at the bottom of the handle then swing the handle to the right to open The handle must be kept in this position p to close the door Return the handle to ES Series Handles the initial position and use the key provided to lock the handle The lock on the side panels will accept the same key The swing handles and doors are reversible ES SERIES Series Handles The mesh contour doors on 30 W ES cabinets use lift up locking handles Simply lift up to release If you are reversing the doors make sure to switch the latch bracket to the other side DOOR REMOVAL AND ATTACHMENT Open the door beyond 90 degrees grasp the door with both hands and carefully lift upward When the door is free of all three hinge pins pull the door away from the enclosure To attach the door align all three hinges of the door to their respective hinge pins on the enclosure and slowly slide the door down until seated Hinge Pin Hinge Door Align al three hinges to anach oor FIELD REVERSIBLE FRONT amp REAR DOORS The front and rear doors are installed right hand hinge as standard from the manufacturer Rem
4. NOT BONDED TO PROTECTIVE EARTHING TERMINAL The following parts are not effectively bonded to the protective earthing terminal rails and front to back rail horizontals If these parts need to be bonded to the protective earthing terminal do so in accordance with Article 250 of the National Electric Code 60 ACCESSORIES STATIONARY SHELVES 19 Rack Mount PART NO 7206 FM 7206 EIA 7206 FR AHD 7206 FR ADHD 7206 FR A28HD 7206 FR A32HD 7206 8T SLIDING SHELVES PART NO 7206 FRSL AHD 7206 FRSL ADHD 7206 FRSLA300 7206 81 7206 DR WIDTH 17 25 17 48 17 50 17 50 17 50 17 50 17 00 DEPTH 1800 1800 2225 27 28 28 00 32 00 2075 19 Rack Mount WIDTH 17 50 17 50 14 33 16 34 16 00 DEPTH 2200 26 00 30 00 17 50 18 875 SPECIALTY SHELVES 19 Rack Mount PART NO WIDTH 7206 MKM 17 00 7206 PKB MT 20 62 VERTICAL POWER STRIPS DEPTH 24 00 950 PART NO OUTLETS LENGTH FEATURES 49 Circuit Breaker 5 15P Plug 5 15R Receptacle 7218 16 7215 5 16 7215 ARTLP 16 7215 20 16 7215 30 24 721824 8 49 Surge Suppressor 5 Receptacle MAX TAB PMT 26 125 32 250 30 180 36 000 25 250 MAX TAB PMT 26 125 32 125 36 12 25 500 MAX TAB PMT 36 12 36 12 WT 60 Ibs 80 Ibs 200 Ibs 150 Ibs 300 Ibs 300 bs 300 bs WT 110 Ibs 110 lbs 300 bs 40 lbs 100 Ibs WT CAP 200 bs NA Plug 5 15R
5. RMU mounting of 19 rack mount power strip units or other 1 or 2 RMU equipment such as patch panels Install the bracket onto the rail or post toward the side panel It is important to ensure you have 18 31 between the inner holes for 19 mounting PDU1 MOUNTING E and ES SERIES The 30 W ES and 29 W E allows for 0 RMU mounting of 19 rack mount power strip units or other 1 RMU equipment such as patch panels You can mount up to twelve 12 1 RMU pieces of equipment this way Install the bracket into the side panel flange Make sure you have 18 31 between the inner holes See detail B fs f Y ik j 1831 Mount R oes 0 8 wi i AIR MANAGER amp FAN TRAY ES SERIES IMPORTANT If you are installing the optional fan tray please install before the air manager The Standard Air Manager will take up the first RMU in the bottom of your enclosure and the High Flow Air Manager will take up the first two RMU INSTALLATION OF FAN TRAY Install four 4 10 32 x 1 2 screws in the middle center of the ES enclosure Make sure to remove the plastic cable guides from the middle rear Place the fan tray on the 10 32 screws Plug in the power cord and ensure that it goes through the small notch of the Air Manager See detail D INSTALLATION OF AIR MANAGER Place the Air Manager in the bottom of your ES enclosure attach using two cage nuts per side Use the wing nuts to secure the
6. rails for easy equipment mounting Flexible Mounting Profile FMP round cable pass through holes and vertical and FMP horizontal cable tie down slots can be found on side of rails 10 RAIL ADJ USTMENT Series rails are attached using a sliding nut plate and a 1 4 20 hex head bolt ES Series rails are attached using 1 4 20 carriage bolt and 1 4 20 hex nut with serrated flange By loosening top and bottom bolts using a 3 8 socket set the rails can be adjusted infinitely front to back STANDARD POWER STRIP MOUNTING E SERIES For your convenience we have provided mounting brackets in the left rear and right rear comers of the enclosure for mounting power strips vertically Typically any power strip shipped with an enclosure wil be installed at the manufacturer To install a power strip in the field remove the 10 32 x 1 2 Ig screws that secure the bracket to the frame Place the power strip into the comer post of the frame and then place one bracket between the top two outlets and install the 10 32 x 1 2 Ig screw into the threaded hole in the frame Then place the other bracket over the power strip between the bottom two outlets and secure to the frame with the DETAIL A same type of screw For ES power stip mounting A see page 11 POWER When using power distribution units PDUs each PDU should be connected to committed branch circuit that is rated for the continuous load of all the equipment conne
7. the equipment connected When not using a PDU each piece of equipment should be connected to a dedicated branch circuit 1 VERTICAL LACING BARS E AND ES ENCLOSURI Vertical facing bar kits include two horizontal lacing bars and one vertical lacing bar When ordered with an enclosure these kits will come pre installed Lacing bars run independently from 19 rack rails and are infinitely adjustable front to back Additional vertical lacing bars are also available Available Lacing Bar Kits include VLB 4832 Lacing Bar Kit 48H x 32 D enclosures VLB 4836 Lacing Bar Kit 48H x 42 0 enclosures VLB 7232 Lacing Bar Kit 72 H x 32 D enclosures VLB 7236 Lacing Bar Kit 72 H x 36 D enclosures VLB 7836 Lacing Bar Kit 78 H x 42 0 enclosures 8432 Lacing Bar Kit 84 H x 32 D enclosures VLB 8436 Lacing Bar Kit 84 H x 36 42 and 48 D enclosures VLB 72 Vertical Lacing Bar 72 H enclosures VLB 78 Vertical Lacing Bar 78 H enclosures VLB 84 Vertical Lacing Bar 84 H enclosures Detail B HORIZONTAL LACING BARS E AND ES ENCLOSURES Horizontal lacing bars are depth specific Double rows of vertical and horizontal slots allow you to use velcro straps or cable ties to secure your cables which you can run from front to rear of enclosure Available Horizontal Lacing Bars include HLB 32 Horizontal Lacing Bar 32 D enclosures Ys HLB 36 Horizontal Lacing Bar 36 42 amp 48 D enclosures OVERHEAD CABLE TROU
8. vertical air defiector After you have installed the Air Manager you can change the amount of airflow by sliding the adjustable panel Available Air Manager and Fan Trays include AM HFES High Flow Air Manager Assembly for ES Enclosures AM HFFTES24 High Flow Air Manager Fan Tray for 24 W Enclosures 940 AM HFFTES30 High Flow Air Manager Fan Tray for 30 W Enclosures 940 AM ES Air Manager Assembly for ES Enclosures AM FTES24 Air Manager Fan Tray for 24 W Enclosures 600 CFM AM FTES30 Manager Fan Tray for 30 W Enclosures 600 CFM Vertical Air efiector Panel Fan Power Plug S Lxx dps Notch in Rear ot Air DETAILD Y Manager For Cord cmo C phain Body Range and Front zn Diverter Mounted to Bottom Wing eo PATE Mounting Mu Mime N NT Main Body kog Flange and Front Diver Bottom RMU on Rail 10 32 x V Z L Self Tapping Adj stable Screws Installed with 1 4 Airflow Gap for Fan Tray Notches to Panel Rest on Qty 4 EXHAUST CHIMNEY amp FAN TRAY ES SERIES INSTALLATION OF ADJUSTABLE EXHAUST CHIMNEY Before installation remove the rear top knockout from the enclosure Place assembled chimney on top and attach from the inside using 10 32 screws Raise the outer section so the seal touches the ceiling INSTALLATION OF FAN TRAY Place fan tray onto fixed portion of the chimney ensuring cord is hanging through the chimney and i
9. 6 44 GL840E 2032 84 29 32 44 GL840E 2936 84 29 36 44 GL480ES 2442 48 24 42 24 GL780ES 2442 78 24 42 42 GL780ES 3042 78 30 42 42 GL840ES 2442 84 24 42 44 GL840ES 3042 84 30 42 44 GL840ES 2448 84 24 48 44 GL840ES 3048 84 30 48 44 ES weight capacity 2000 Ibs E weight capacity 1500 Ibs INSTALLATION Receiving Unpacking and Removing the E or ES Enclosure from the Pallet Inspect and report any damage before receiving Unpack the enclosure by carefully removing the corrugated carton and corners Avoid damaging the enclosure when removing packaging A WARNING Only trained service personnel should be used to remove the enclosure from the pallet Also be sure you have a sufficient number of service personnel Do not attempt to move enclosures by yourself A WARNING Be careful when moving enclosures before installation Sudden stops and starts excessive force obstructed routes and uneven floor surfaces may cause the enclosure to topple over Loading Equipment A WARNING Only install equipment after the E and ES Enclosure has been properly secured Do not move the E and ES Enclosure assembly while loaded Once in place at the desired intended location deploy the leveling feet for maximum stability Rated or maximum load capacity for the E and ES Enclosure is 1500 and 2000 pounds respectively on the floor or on leveling glides To maintain a uniform distribution of the mechanical load in the E and ES Enclosure
10. GH ES SERIES When ordered with the enclosure the Overhead cable trough ships assembled but not installed When ordered separately the trough will stil ship assembled The top of the ES enclosure has a variety of mounting holes Place the trough where you require cable routing For 24 W enclosures use the TCT24 for 30 W enclosures use the TCT30 LADDER RACK BRACKET ES SERI The LRB 12 to support 12 rack and LRB 24 to support 18 and 24 rack is a single ladder rack bracket with instalation paa hardware Two badder Rac menie Baa required per 2 enclosure AA Gee detai 516 18 Hex Nut two brackets 5116 18 are installed you Fiat Bot f can attach your 5 1618 ladder rack Flat Washer LADDER RACK ATTACHMENT HOLES E SERIES All E Series tops have pre drilled cable runway attachment holes Sie 18 3 I Bolt EXTERNAL CABLE MANAGER SIDE CAR ES SERIES The side car SC128442 is a 42 W external cable manager for 84 H enclosures It can be mounted between two enclosures or mounted on single enclosure The side car has two vertical troughs 84 H x 12 W x 37D fingers and attachment points for cable ties and cinch straps For complete side car installation instructions visit werackyourworid com drawings a ZERO RMU MOUNTING ZR1 amp ZR2 E and ES SERIES Both ZR bracket kits fit on the 30 W ES and 29 W E enclosures These allow for 0
11. GREAT LAKES yp 4 CASE amp CABINET E and ES Series Enclosures Installation Instructions WeRackYourWorld com 1 866 TRY GLCC 879 4522 Instructions for the following Great Lakes Enclosures GL720E 2432 GL720E 2436 GL720E 2932 GL720E 2936 GLB40E 2432 GLBA0E 2436 GL840E 2992 GLB40E 2936 GL4B0ES 2442 GL7B0ES 2442 GL7A0ES 3042 GL840ES 2442 GLBA0ES 3042 GLBAOES 2448 0 5 3048 PREFACE This manual is provided to prevent service personnel from committing an act that results in the risk of fire electric shock or injury to persons Only trained service personnel should receive unpack and assemble the E and ES Enclosures In addition only trained service personnel should install equipment in enclosures SAFETY SYMBOLS USED IN THIS MANUAL This manual provides general safety guidelines to be observed during installation operation and maintenance of the E and ES Enclosure A WARNING Failure to follow directions in the warning could result in injury to persons or loss of life A CAUTION Failure to follow directions in the caution could result in damage to equipment or storage data SAFETY CONSIDERATIONS A WARNING Improper handling and use of the E and ES Enclosure could result in equipment damage serious injury or possible death Only trained service personnel should be used to remove the enclosure from the pallet Also be sure you have a sufficient number of service personnel Do n
12. U 20 10 18 10 6 00 12007 NOTED TNT NETWORKING GANGING Enclosures can be networked using the following networking ganging kits 9101 Networking Ganging Kit to gang two E Enclosures pictured 910185 Networking Ganging Kit to gang two ES Enclosures GIO1EN2ES Networking Ganging Kit to gang an EN Enclosure to an ES Enclosures Washer Washer Lock Washer Wing Thun pod No Tools Required GROUNDING GROUNDING KIT GR101 Grounding studs in our E and ES Series enclosures provide a point to which the doors may s be grounded to the enclosure and from which the enclosure may be connected to the facility s common ground The studs are made from copper Which is a conducting metal E Enclosures have three ground studs in the frame wo in top and ound Stud in the bottom ES Enclosures have two ground studs in the bottom rear of the frame or M x 50mm LG This kit allows you to ground the enclosure so that it is ready to be connected to the common building ground Using the grounding straps supplied connect one end of the strap to copper ground stud on the side panels and or doors and the other end to copper ground stud on the frame of the enclosure Once all straps have been connected to a copper frame stud have at least one frame stud connected to the comman building ground 24 COPPER BUS BARS itis important to note that grounding th
13. cted When not using a PDU each piece of equipment should be connected to a dedicated branch circuit n UNIVERSAL POWER STRIP BRACKETS E SERIES Great Lakes offers a universal power strip bracket kit These brackets allow you to mount a PDU with button mounting See drawing PSBKE 02 x some E eres POU Spring 3 8 Flat Clips 1082 Nut ead PanHead Tinnerman with Lock b des ese Sew Som mess To mount Universal Power Strip Brackets in an E enclosure or cabinet extension measure the required mounting distance top to bottom install brackets then install power strip 110 32 Nut with p Le Washer noaza Ta luam f 10 32 x 112 Tnermart Clips Pan Head Screw Optional MOUNTING IN A CABINET EXTENSION 30 32 Nat with Lock Washer 3510 32 Nut with Lock Washer 10 32 x 3 8 10 32 x 112 Flat Head Screw Pan Head Screw DM a OPTIONAL ACCESSORIES PLASTIC CABLE MANAGEMENT FINGERS ES SERIES The CM 47 and ESC K12 consist of 7 RMU sections of fingers that mount to the Flexible Mounting Profile FMP of ES Enclosure rails the 47 is a single section while the ESC K12 is a kit of 12 sections Fingers can be installed on the front or rear rails but front rails must be recessed 4 5 for proper installation It is recommended that each 47 be installed using 3 points of attachments Tac ESC K12 Cable Management Ki
14. e enclosure does not ground the equipment mounted within it In order for any individual devices and components mounted within an enclosure to be grounded they must be connected to a copper bus bar Available copper bus bars include CBB 19 Copper Bus Bar for 197 rack mounting Isolated CBB 48 Copper Bus Bar for 48 H enclosures Isolated CBB 60 Copper Bus Bar for 72 H enclosures Isolated CBB 72 Copper Bus Bar for 78 and 84 H enclosures Isolated PROTECTIVE GROUNDING Protective grounding studs are provided along with grounding jumper wires that electrically bond the enclosure doors to the enclosure frame A WARNING To avoid injury to persons or loss of life ground each enclosure individually to the dedicated branch circuit ground CONNECTING MAIN PROTECTIVE GROUNDING STUD TO THE DEDICATED BRANCH CIRCUIT GROUND Connect the dedicated branch circuit ground connector to the main protective grounding stud located inside at the bottom rear of the enclosure frame using a listed ring or closed loop terminal CONNECTING MAIN PROTECTIVE GROUNDING STUD TO THE PROTECTIVE BONDING CONDUCTORS Connect the rear doors to the main protective grounding studs located inside at the bottom and top rear of the enclosure chassis using a listed ring or closed loop terminal Connect the front door to the grounding stud located inside at the bottom front of the enclosure frame using a listed ring or closed loop terminal PARTS
15. e note that the chart and following information also references EN Enclosures Baffle Kits create proper airflow for switches and side to side airflow equipment as suggested by manufacturers such as CISCO Cool air is channeled into the equipment along the right side and exhaust air is directed out along the left side of the equipment Kits are tool less and easily attach to rails outside of the EIA mounting profile Kits available for 25 19 14 and 11 RMU equipment are unique to ES and EN enclosures creating the perfect fit between switch and enclosure Recommended Great Lakes Great Lakes Enclosure Baffle Kit Part No EN Series Series EN Enclosure Enclosure Baffle Ki 7018 8401EN 4048 NA ENSAB25 NA 9513 B401EN 3242 XXOTES GOXX ENSABI4D ESSABIAD 95097 B407EN 3242_ XXO1ES 30XX ENSABI4 ESSABI4 6513CE 8401 3242 XXO1ES 30XX ENSABIO ESSABIS G509 E 8401 3242 XXO1ES 30XX ENSABI4 ESSABi4 6506CE 8401 3242 XXO1ES 30XX ENSABH ESSABH Four post mourning s requires wi a ral placement or 21 n ational 75 of height is requred or fal mount brackets brackets be removed ater chassis ie instale 22 CHOOSING YOUR BAFFLE KIT amp ENCLOSURE Based on your switch equipment choose the appropriate EN or ES enclosure Take into consideration your cable management cooling and power needs each enclosure addresses t
16. hese needs in different ways Baffle Kit part numbers are specific to ES or EN Enclosures The chart below shows which kits accommodate various CISCO switches Other brands of side to side airflow equipment can also be mounted To determine the correct enclosure and baffle kit compare physical equipment dimensions to what is listed For detailed instructions on how to install your baffle kit please refer to the instructions provided with your baffle kit These instructions are also available at werackyourworld com tough equipment may Pcia risa Great Lats enclosure wth or wihout brackets customers Mista evan nad San wah e annon muet Rao and he For italic a 7018 Senes sch however Me and ES encosue tas dates ot Creat Late EN Enhanced Nelworung Senes ol ences designat la supa he naan of Cisco ren vedo ha eleg bale We at ate despre a supo oe praem ion Far mor reads cont your Great d al LGB TR GLOC Sea to wi nol be aponte er ary erana or dam mi casters SIE sacri barr party proc ny Grea Lata cios iss caused ay Seen nn pars Gret tan cian ed oy tl Physical Equipment CISCO Recommended Dimensions Clearances Equipment Equipment to to Wall Equipment 25RMU 43757 32007 1100 2200 14 RMU 2450 28 00 12007 14 RMU 2450 1840 6 00 19 RMU 3330 1840 12007 14 RMU 2520 18 10 12 00 TIRM
17. ill accept a two 2 hole fan assembly 7217LE2 The mesh contour door for the 30 and 29 W enclosures will accept a three 3 hole fan assembly T217LE3 Both of these fan assemblies simply need to be attached to the door using the supplied 10 32 hardware The fans should be placed where you need to alleviate a hot spot Increments BRUSH GROMMET KIT ES SERIES The brush grommet kit is best installed before any equipment is installed in the enclosure Please refer to detail A for mounting and hardware usage BGRK24 is for use with 24 W ES enclosures while the BGRK30 is for use with 30 W ES enclosures 19 EIA Equipment Mig Brush Strips Flexible PVC 1 L Trim Rails Shown for reference Slides Onto Outside Edge of Mounting sor iq Included with Enclosure Plates that are Installed Onto Front Eouipment Face of the Equipment Rails pie Top Cross Shown for Ts mes Reference Include with Enclosure Velia Brush Stip Mig Plates 2 Tool less Hardware Lu Ihe Push Pull Nylon Rivet Brush Strips Flexible PVC 1 L Trim Slides Onto Outside Edge of Mounting Mount 1 4 Thru Plates that are Installed Onto Front on Front Face of Rails Face of the Equipment Rails a BAFFLE KITS Baffle Kits can be installed in ES Enclosures and Great Lakes EN Enclosures visit werackyourworld com for installation instructions While this user s manual is specific to ES E enclosures pleas
18. ive seal and mount to four internally threaded studs using 10 32 x 12 lg phillips pan head screws The back opening can be covered with a solid metal cover These covers are specific to the width of the enclosure BOTTOM PANEL ES SERIES Bottom Panels brush grommet and solid for the ES series comes in two sections One for the middle opening and one for the rear Once you have unpacked the large flat rectangular middle section place it in the bottom of the enclosure with the magnetic strip down The rear section is ready to go Remove the plastic cable clips Find the push in fasteners 2 in the hardware bag line up the holes in the bracket with the rear opening of the enclosures and attach DETAIL 2 REVERSE SIDE Panel Slides Into Bottom Rear of Enclosure Between Rear Stiffener and Rear Door Jamb Use Push Clips to Secure in Place 2 0 25 Holes and Flush with Stifener 2 places Magnetic Strip Hold Botiom of Panel to Enclosure MOUNTING RAILS The vertical mounting rails each enclosure has two pairs 12 ga steel powder coated rails come installed with all standard frames at 19 EIA 310 E The 29 W Series enclosure and 30 W ES enclosure can be configured to 23 EIA mounting with an optional replacement bracket set Universal cage nut rails M6 are standard Tapped 10 32 rails are available Must be specified at time of order Rack Mount Units RMU are marked on
19. nto the enclosure The fan will rest on four studs Secure the fan with 10 32 nuts from the inside of the enclosure Available Chimney and Fan Trays include GL ECHF 48 1832 High Flow Chimney for 48 D enclosure with an adjustable range of 18 to 32 GL ECHF 48 3246 High Flow Chimney for 48 D enclosure with an adjustable range of 32 to 46 GL ECHFFT48 High Flow Fan Tray for 48 D enclosure 2260 CFM GL EC 48 1832 Chimney for 48 D enclosure with an adjustable range of 18 to 32 GL EC 48 3246 Chimney for 48 D enclosure with an adjustable range of 32 to 46 GL ECFTA8 Fan Tray for 48 D enclosure 1200 CFM GL EC 42 1832 Chimney for 42 D enclosure with an adjustable range of 18 to 32 GL EC 42 3246 Chimney for 42 D enclosure with an adjustable range of 32 to 46 GLECFT42 Fan Tray for 42 D enclosure 1200 CFM lt E Adjust Chimney to Desired Cord for Fan Tray to lt gt Height Use Serewariver to Exit back Through Punch Out Appropriate the Chimney and 22 Knockout for Knob QU 2 Both Sides Rear of Enclosure j Drop Fan Tray Into Fixed Bottom Portion of Chimney Noiches Should Fall Onto Studs in Chimney 10 32 x 1271 Mounting Screws Qty 4 Install Nuts Onto Studs Mounting Holes from Bottom Inside For 10 32 Enclosure Qty 4 Screws Qty 4 Use Screwdriver E to Punch Out lt Rear Knockout 20 MESH CONTOUR DOOR ES SERIES The mesh contour door for the 24 enclosures w
20. ot attempt to move enclosures by yourself Only UL Listed ITE Information Technology Equipment units should be installed inside the E and ES Enclosure Be sure to read and follow all individual manufacturer equipment manuals for safety and installation instructions Proper spacing is required when installing electrical equipment to avoid electrical shock Maintain minimum spacing between the accessories and components and the computer enclosure assembly for safe operation of the equipment when installed in accordance with the National Electric Code 70 1999 The ambient temperature operating range for the E and ES Enclosure and accessories is 50 to 95 F 10 to 35 C The non operating temperature is 4 to 140 F 20 to 60 SERVICE The E and ES Enclosures should be repaired by personnel trained by Great Lakes or returned to Great Lakes for repair or replacement Contact Great Lakes Technical Support at 814 734 7303 or at werackyourworld com WHAT S INCLUDED E or ES unit assembled Keys as needed depending on configuration 60 M6 cage nuts 3 8 square and screws 10 32 tapped rails available must be specified at time of order This user s manual This user s manual applies to the following Great Lakes enclosures Part No H w D RMU GL720E 2432 72 24 32 37 GL720E 2436 72 24 36 37 GL720E 2932 72 29 32 37 GL720E 2086 72 29 36 37 GL840E 2432 84 24 32 44 GL840E 2436 84 24 3
21. oving the hinges allows you to reverse the door by flipping them over and reinstalling the hinges using the universal mounting holes Begin both screws then tighten while maintaining perfect vertical alignment See detail below All enclosure frames and doors have provisions to be hinged right or left hand The handle can be reversed along with the hinging See Operating Handle on page 5 HINGE MOUNTING Reversable Hinge Female a Pivot Washer ru Reversable lt pol Hinge Female Flat Head Flat Head Philips Screw Philips Screw 10 32 x 112 10 32 x 1 2 DOOR DETAIL Frame 7 SIDE PANEL REMOVAL The side panels are secured to the enclosure frame with two quick release latches and a keyed lock Be sure to unlock the side panel To remove the side panel squeeze the quick release latches towards each other Then tilt the top of the side panel out slightly and lift the side panel up a couple of inches until itis free To install the side panel reverse the process Make sure the slots on the side panel engage with the two tabs at the bottom of the frame ADJ USTABLE LEVELER MOUNTING E SERIES On the bottom of the cabinet there are eight threaded holes two in each comer The outside holes are threaded 1 2 13 thds and will accept the levelers Once the levelers 7209 N or 7209 N4 are installed the cabinet level can be adjusted with the use of a 3 4 open end wrench
22. river 4 Repeat steps 2 and 3 for the three remaining casters 5 Install leveling glides 7209 N at this time if they were ordered with the enclosure 4 112 13 Threaded Holes _ 4 Adjustable Levelers m 5 16 18 Threaded Studs Lo le Counter clockwise rotation will adjust the leveling glide up Clockwise rotation wil adjust the leveling glide down TOP PANEL MOUNTING ES Enclosure The top panel of the enclosure is installed at the manufacturer Removing the top panel can be done by removing the four 10 32 x 1 lg philips pan head screws E Series or the four 10 32 x 1 2 lg screws ES Series Then simply lift the top panel out or off Top panels are available for 24 W TPE 24 and 29 W TPE 29 E Enclosures There are 5 options for E Enclosures indicates enclosure width in part number TPE S TPE P TPE FI0 TPE 2FI0 Solid Perforated Three 10550 Two 10 550 75 Fans There are 6 top panel options for ES Enclosures TPES S TPES FIO TPES2FI0 TPES B Solid Perforated _ Three One 10 550 Two 10 550 Grommet 75 Fans CFMFans Brush BOTTOM PANELS E SERIES There are several styles of panels available for the bottom of your E Series enclosure Optional panels are solid filtered or brush grommet These panels have foam gasketing for a posit
23. t Front or Rear HCM D36ES MOUNTING 30 W ES SERIES HCM D36ES are horizontal cable troughs that can be used in the ES enclosures If these parts are ordered with the enclosure they are pre installed If you need to move the trough please do so before ganging enclosures These troughs are installed between the side panel and the 19 rack mount rails Side panel will have to be removed before installation See detail VERTICAL CABLE TROUGH amp PDU MOUNTING SERIES For GL780ES GL840ES The ES enclosures come with a universal power strip bracket set in both rear corners These bracket sets wil accept a wide range of Power Distribution Units PDUs and will also accept vertical cable troughs The VCT 78 and VCT 84 3 W x 2 572 D are ES enclosure vertical cable troughs Figures A B C amp D show the bracket and the usable mounting space in 42 D enclosures brackets in 48 D enclosures not pictured have six sets of holes The size of the PDU will determine how many of them you will be able to place on the brackets Keep in mind the VCT are 3 W The location of the button mounting will also need to be taken into consideration when placing your PDUs M AP hr p ier Ji J dk Detail F POWER When using power distribution units PDUs each PDU should be connected to a committed branch circuit that is rated for the continuous load of all