1. Changes NMM Agent Software Update Updating the Agent Software allows administrators to upgrade the firmware within the management module and take advantage of new features To update the Agent software type 9 at the Management Options menu The NMM will display the following Enter Choice Help h Exit x gt 9 UPDATE Are you sure Y N gt Y Please Xmodem file now From your terminal program use the Xmodem protocol to send the new IC_agent xxx agent file to the NMM where xxx represents the release level of the software Page 12 modifications or tampering with equipment including removal of equipment cover by personnel not specifically authorized and certified by Omnitron or misuse or operating outside the environmental specification of the product including but not limited to voltage ambient temperature radiation unusual dust etc or improper site preparation or maintenance No other warranty is expressed or implied Omnitron specifically disclaims the implied warranties of merchantability and fitness for any particular purpose Exclusive Remedies The remedies provided herein are the Buyer s sole and exclusive remedies Omnitron shall not be liable for any direct indirect special incidental or consequential damages whether based on contract tort or any legal theory Technical Support For help with this product contact our Tech Support Phone 949 250 6510 Fax 949 250 6514 Address
2. Omnitron Systems Technology Inc 27 Mauchly 201 Irvine CA 92618 USA E mail support omnitron systems com URL http www omnitron systems com Form 040 08000 002 7 02 Page 16
3. Choice Management Options Screen 0 Help h Exit x gt Setting the SNMP Read and Write Community Names The SNMP Read Community Name is necessary for reading data from the NMM The name can be any 1 31 character alphanumeric string Page 10 Accessing the NMM via FTP The agent software on the NMM can be updated via FTP using any standard FTP client FTP access can be enabled or disabled via serial cable only at the P and Control Preferences screen This screen also contains an option to set the FTP password FTP will not work without a password To update the agent software log in as user ost and use the password set during the NMM s configuration Upload the new agent software into the root directory When the file transfer is complete the NMM will verify the file and then restart using the new file NMM Specifications Model NMM Pratecols IP UDP SNMP TCP TFTP ARP ICMP Telnet FTP Copper RJ 45 DB 9 Connectors Controls UTP Xover Front Backplane LED Pwr Pwr supply 3 UTP Link Displays Master Slave Mgt Poll Supported RFC1155 RFC1156 RFC1157 MIB s RFC1212 RFC1213 OST MIB Dimensions W085 xD 4 5 xH 2 8 Weight 8 oz Compliance UL CE FCC Class A Uea iee 40 to 80 C Storage Altitude 0 10 000 ft MTBF hrs 1 336 898 Page 14 To set the SNMP Read Community Name type 4 at the SNMP Preferences Screen Enter Choice Management Options Screen 0 Hel
4. IP Address and Control Preferences screen Page 6 When the Ethernet Port switch is in the back position the front panel port becomes disabled and the backplane port is enabled In the backplane mode the NMM module can communicate to an adjacent 10 100 module Mounting iConverter modules are hot swappable and can be installed into any of the iConverter family of Chassis 1 Carefully slide the iConverter Slide in Module into installation slot aligning the iConverter Slide in Module with installation guides 2 Secure Slide in Module by securing panel fastener screw attached to Slide in Module to chassis front 3 If multi chassis grouping is desired connect the NMM sS together using the iConverter NMM Cascade Cable Model 8080 3 4 When front plane Out of Band Management is desired attach the RJ45 Ethernet port via a Category 5 UTP cable to a 10Base T capable Ethernet device LED Indicators LED Color Description Pwr Yellow On Power PS1 Yellow On Power Supply 1 OK PS2 Yellow On Power Supply 2 OK PS3 Yellow On Power Supply 3 OK Msr Slv Green On Master Off Slave Mgt Green On Management Polling Lk Rx Green On 10BT Link Blink Activity Page 3 Enter Choice Management Options Screen 0 Help h Exit x gt 1 Change IP 192 168 1 220 Backspace over the existing value type the new value in x x x x format and press lt ENTER gt To configure the subnet m
5. ackplane 10 Mbps Ethernet management interface port and a pair of multi chassis management ports enabling it to manage up to 16 chassis using a single IP address Board Mounted Switch Settings NMM PLUG IN MODULE m WORKSTATION SWITCH FRONT BACK ERRRRHHHIT Ethemet X Over Switch Back Plane Enable RJ45 Cross Over Switch When connecting the Ethernet front plane to a hub or switch set the switch to switch When connecting to a workstation set to workstation factory setting Ethernet Port Back Plane Management Switch When the Ethernet Port switch is in the front position factory setting the front plane RJ45 Ethernet port is enabled and the backplane Ethernet port is disabled Page 2 192 168 1 220 To configure the IP address and control paramenters press 3 from the Management Options menu The following menu should appear IP and Control Preferences Screen iConverter Serial Agent v1 3 Set NMM IP Set NMM Subnet Mask Set Gateway Chassis Number Chassis Name also sysName 6 Enable Disable Telnet 7 Enable Disable FTP 8 Enable Disable Redundancy 9 Enable Disable Soft switch onie w a He Reload 10 Telnet Password Ils FIP Password 12 Serial Password 13 Restore NMM Configuration Defaults Enter Choice Management Options Screen 0 Help h Exit x gt Setting IP Parameters To configure the IP address of the NMM press 1 atthe
6. aining the iConverter NMM and press lt ENTERs gt to bring up a command line prompt at the attached PC If a password has been set the following information will be displayed OS Initialized and Running Task Creation Complete Beginning Discovery IP Addr 192 168 1 220 Omnitron Systems Technology Inc iConverter Serial Agent v1 3 Copyright 2001 2002 OST Inc Password Entry Omnitron Systems Technology Technical Support 949 250 6510 27 Mauchly 201 Sales Products 800 675 8410 Irvine CA 92618 On the web at www omnitron systems com Page 4 must be in the range 1 to 16 where 1 is the master NMM In a single chassis configuration set this entry to 1 The Chassis Name or sysName allows the network manager to identify the NUM by acommon name The name can be any 1 31 character alphanumeric string To set the Chassis Number press 4 at the IP Address and Control Preferences screen Enter Choice Management Options Screen 0 Help h Exit x gt 4 Change Chassis Number lt 1 16 gt To set the Chassis Name or sysName press 5 at the IP Address and Control Preferences screen Enter Choice Management Options Screen 0 Help h Exit x gt 5 Change Chassis Name lt 1 31 char acter alphanumeric gt To save the new values press 0 to return to the Management Options menu then press 6 to Save NMM Preference Changes Setting NMM Passwords The NMM is shipped from the factory with no pa
7. ask of the NMM press 2 at the IP Address and Control Preferences screen Enter Choice Management Options Screen 0 Help h Exit x gt 2 Change Subnet 255 255 255 0 Backspace over the existing value type the new value in x x x x format and press lt ENTER gt To configure the gateway of the NMM press 3 at the IP Address and Control Preferences screen Enter Choice Management Options Screen 0 Help h Exit x gt 3 Change Gateway 192 168 1 1 Backspace over the existing value type the new value in x x x x format and press lt ENTER gt To save the new values press 0 to return to the Management Options menu then press 6to Save NMM Preference Changes Setting the Chassis Number and Name In a multi chassis configuration each chassis must be assigned a unique number In this configuration multiple chassis are cascaded together and are monitored and controlled from a single NMM IP address The numbers Page 7 When using the iConverter for the first time initial configuration is required To configure attach the NUM to a serial RS 232 equipped PC with terminal emulation software such as HyperTerminal To attach use a straight through serial cable with a DB 9 male connector to connect to the NMM Model 8081 3 Attach other end of the cable to the serial RS 232 port of the PC Set the PC s serial port to the following bits per second 57 600 stop bits 1 data bits 8 parity NONE Power the chassis cont
8. ginal purchaser by REGISTERING this product with Omnitron within 90 days from the date of shipment TO REGISTER COMPLETE AND MAIL OR FAX THE REGISTRATION PORTION OF THIS INSTRUCTION MANUAL TO THE INDICATED ADDRESS Or you may register your product on the Internet at http www omnitron systems com During the warranty period Omnitron will at its option repair or replace a product which is proven to be defective For warranty service the product must be sent to an Omnitron designated facility at Buyer s expense Omnitron will pay the shipping charge to return the product to Buyer s designated US address using Omnitron s standard shipping method Limitation of Warranty The foregoing warranty shall not apply to defects resulting from improper or inadequate use and or maintenance of the equipment by Buyer Buyer supplied equipment Buyer supplied interfacing unauthorized Page 15 To enter the IP address of the first trap monitoring station type 6 at the SNMP Preferences Screen Enter Choice Management Options Screen 0 Help h Exit x gt 6 Change Traphost Address 1 255 255 255 255 Backspace over the existing value type the new value in x x x x format and press lt ENTER gt To enter the IP addresses of additional trap receiving management stations repeat this process for Traphost Addresses 2 8 To save the new values press 0 to return to the Management Options menu then press 6 to Save NUM Preference
9. ogram File ash Server Program Decoded Flash Server Checking Program Address Range ash Server Program Range ok ash Server Erasing Flash Flash Server Flash Erased ash Server Programming Flash ash Server Flash Programmed ash Server Verifying Flash Program ash Server Flash Program Verified ash Server REBOOTING NMM TO LOAD NEW PROGRAM The NMM will then restart using the new agent software Accessing the NMM via Telnet The NMM may be accessed and configured via telnet using any standard telnet client All of the functions available with serial cable access are available with telnet access with the exception of agent software updating see Accessing the NMM via FTP below Telnet access can be enabled or disabled via serial cable only at the P and Control Preferences screen This screen also contains an option to set the telnet password Telnet will not work without a password Page 13 To set the NMM s SNMP preferences press 4 from the Management Options menu The following menu should appear SNMP Preferences Screen iConverter Serial Agent v1 3 Chassis Number 1 sysName also Chassis Name sysContact sysLocation Read Community Name Write Community Name Traphost Address Traphost Address Traphost Address Traphost Address 10 Traphost Address 11 Traphost Address 12 Traphost Address 13 Traphost Address 14 Restore SNMP Configuration ODANHDUBWNE DADO AUNE Enter
10. osr Omnitron Systems Technology Inc iConverter NMM Network Management Module User s Manual iConverter Network Management Module Model Description 8000 0 SNMP Management Module NMM Optional Accessories mope SESE 8080 3 NMM Cascade Cable 3 ft 8081 3 NMM Serial Cable DB 9 3 ft 8100 0 NetOutlook SNMP Software for Windows 9X ME XP NT 2K Page 1 IP Address 192 168 1 220 MAC 00 06 87 00 0A7 2C Please enter the password gt Enter the password and hit lt ENTER gt The NMM should respond with the Management Options menu If there is no password the NMM will skip the above message and go straight to the Management Options menu Management Options iConverter Serial Agent v1 3 Network Management 1 Chassis and Module Management 2 Set Module Name NMM Preferences 3 IP and Control Preferences 4 SNMP Preferences 5 Abandon NMM Preference Changes 6 Save NMM Preference Changes 7 Restore Factory Defaults 8 Restart NMM NMM aintenance 9 Firmware Update IP Address 192 168 1 220 Chassis Number 1 Enter Choice Help h Exit x gt IP and Control Preferences An IP address is required for the SNMP manager to address the NMM Its initial factory setting is Page 5 Description The iConverter NMM Network Management Module provides SNMP based monitoring and control for the iConverter product family The NMM features a serial port for configuration a front plane or a b
11. p h Exit x gt 4 Change Read Community Name public Backspace over the existing value type the new value and press lt ENTER gt The SNMP Write Community Name is necessary for writing data to the NMM The name can be any 1 31 character alphanumeric string To set the SNMP Write Community Name type 5 at the SNMP Preferences Screen Enter Choice Management Options Screen 0 Help h Exit x gt 5 Change Write Community Name public Backspace over the existing value type the new value and press lt ENTER gt To save the new values press 0 to return to the Management Options menu then press 6 to Save NMM Preference Changes Setting the SNMP Trap IP Addresses SNMP traps are used to report events that occur during the operation of a network that require the attention of the network administrator The NMM is capable of sending SNMP traps to up to eight different SNMP management stations Page 11 Warning The operating description in this Instruction Manual is for use by qualified personnel only To avoid electrical shock do not perform any servicing of this unit other than that contained in the operating instructions unless you are qualified and certified to do so by Omnitron Systems Technology Inc Warranty This product is warranted to the original purchaser against defects in material and workmanship for a period of TWO YEARS from the date of shipment A LIFETIME warranty may be obtained by the ori
12. ssword protection It is highly recommended that the network administrator set a new password in order to prevent unauthorized access to the unit To set the password for telnet access type 70 at the IP Address and Control Preferences screen Page 8 Enter Choice Management Options Screen 0 Help h Exit x gt 10 Enter New Telnet Password gt lt password gt Please enter again to verify gt lt password gt To set the password for ftp access type 11 at the IP Address and Control Preferences screen Enter Choice Management Options Screen 0 Help h Exit x gt 11 Enter New FTP Password gt lt password gt Please enter again to verify gt lt password gt To set the password for serial access type 12 at the IP Address and Control Preferences screen Enter Choice Management Options Screen 0 Help h Exit x gt 12 Enter New Serial Password gt lt password gt Please enter again to verify gt lt password gt To save the new values press 0 to return to the Management Options menu then press 6 to Save NMM Preference Changes SNMP Preferences Because the NMM uses SNMP based management the SNMP Preferences must be properly set for full functionality Page 9 Once the file transfer begins the data will upload to the NMM The process will take about four minutes over a serial connection When the upload is complete the NMM will display File received correctly Flash Server Decoding Pr

Download Pdf Manuals

image

Related Search

Related Contents

Onboard vehicle system and method for configuring vehicle  Wireless 802.11b/g/n 150Mbps AP Router User Manual  Technical Assistance to the Kingdom of Cambodia for the  User Guide  The CEL Manual (v0.9b)  Doc - France Industrie sa  Port Designs London  NI PXIe-1082 User Manual  Programme - CClin Sud-Est  ASUS T100TAF User's Manual  