1. 2 52A 4 4 Thermal safety Xelee devices feature a built in thermal safety Internal sensor detects temperature rise in harsh operating conditions preventing the device overheating and malfunction If the temperature rises above certain threshold output power is limited and connected LEDs are dimmed Improvement of thermal conditions causes the device to return to normal operation www nelectrica com page 14 XELEE PowerLED Driver User Manual 5 Connecting accessories 5 1 External switch Xelee devices can be controlled by standard one position bell push type lighting switch The switch should be connected to pins 3 and 4 of DMX512 IR SW IN connector Detailed control description can be found in Xelee devices control document 5 2 IR remote Xelee devices can be controlled with IR remote available as additional accessory To enable remote operation IR receiver should be connected to driver s DMX512 TR SW IN connector Detailed control description can be found in Xelee devices control document Driver and remote IR channel change feature allows usage of two different remotes and drivers in close distance Each Xelee driver and IR remote can be set to one of two IR channels To change remote IR channel hold MENU and ON OFF buttons for 10 seconds To change Xelee driver IR channel use the IR remote operating on the same IR channel and hold MENU button for 15 seconds Two resets will occur during the
2. DMX512 controller or repeater operation max 14 bit per channel resolution dedicated software for monocolor and multicolor lighting built in thermal safety for harsh operating environment software modifications available for special orders compact dimensions thermal protection for harsh environment operation Dane techniczne Parameter Symbol Min Typ Max Unit Additional info Maximum supply current I sup max 4 A channel Output current Tour 350 700 mA Single channel Maximum supply power Psup max S 90 W resolution Efficiency N z 90 E 14 bit only in Xelee show mode Output resolution RES 8 14 bit Output refresh rate Fout S 366 Hz Ambient temperature Ta 20 40 PG Maximum case temperature Te e 80 S www nelectrica com page 3 XELEE PowerLED Driver User Manual Available software options RGBW RGB MONO Dimensions 113 7 22 Order codes P N XxX 10 Current value for Software Software version consecutive channels W RGBW Current 1 0 WRGB R RGB 0 disabled M MONO 3 350 mA 5 500mA 7 700 mA Example P N 3377XW10 www nelectrica com page 4 XELEE PowerLED Driver User Manual 2 DMX receiver operation Xelee devices can operate with DMX512 input signal The brightness of LEDs connected to each output is set to the level corresponding with received DMX512 channel value The signal is regenerated and sent to DMX512 ou
3. operation and the IR CH LED indicator will change it s status Xelee PowerLED User Manual version 1 2 EN publication date 25 06 2011 All information contained in this document are destined only for information purposes The author has put best effort to keep all the information reliable All information can be changed without any notice ALS company does not hold responsibility for any technical and editing errors or lack of information in this document The newest version of the document is available on www als company p website All used product names can be registered trademarks of certain companies ALS company does not hold responsibility for any direct and indirect damage caused by using the information included in this document All installation and configuration operations on described equipment should be conducted according to obligatory regulations ALS company product and service warranties are described in proper warranty statements Any statement included in this document can not be considered as additional warranty www nelectrica com page 15
4. terminator operation Micro switch settings are loaded after switching on the driver s power supply Autoaddressing mode is indicated by diagnostic LED ADR TERM ADR SW SW LED Autoaddressing ADR SW ADR LED OFF OFF position not lit ON ON position lit Terminator TERM SW OFF OFF position ON ON position 2 2 4 Configuration using PC Advanced configuration of Xelee driver settings is possible using PC computer Xel_USB interface and Xelee Programmer application PC software allows the change of outputs DMX addresses selection of autoaddressing mode and other diagnostic operations With proper selection of configuration options software configuration of autoaddressing mode can override the hardware switch setting removing the need to physically access the device during the system reconfiguration Detailed configuration description can be found in Xelee Programmer application s doccumentation www nelectrica com page 9 XELEE PowerLED Driver User Manual 3 Independent driver operation 3 1 Light shows Xelee devices can change the output LED brightness according to preloaded light show sequences Show presentation starts automatically after turning on the power supply if there is no DMX512 signal present on the input If the input signal is present the device switches from light show presentation to receiver operation Stopping the DMX512 t
5. the bus has to have it s built in terminator switched ON with the TERM SW switch Maximum length of the stub connection between the driver and the bus is 3m Us Sei Ua a Xelee driver terminator OFF Xelee Xelee driver driver terminator terminator SEB eee terminator OFF OFF RH E DMX512 Signal RJ 45 passive splitter Patchcord UTP cat 5e www nelectrica com page 6 XELEE PowerLED Driver User Manual 2 1 3 Mixed topology Xelee devices network can be also built in mixed topology keeping all rules for both previous topologies Devices which operate as the only receiver for transmitting device daisy chain should have the built in terminator switched ON Devices connected to shared bus should have the built in terminator switched off except for the last device at the end of the bus 5090 JOU Kee boool H900 pood SES DOO0 podaj driver driver terminator terminator ON driver DMX512 terminator Signal RJ 45 PASSIVE LA splitter Daisy E is SE 5000 5000 UL sl JOOU f NA al 15000 poodi IL D000 panel OOO 2 DR J Xelee Xelee Xelee driver driver driver terminator terminator terminator ON Bus Daisy chain www nelectrica com page 7 XELEE PowerLED Driver User Manual 2
6. 2 Configuration 2 2 1 Address settings Default settings of Xelee device assign LED outputs to 1 4 DMX512 addresses Changing this settings is possible with Xelee Programmer PC software and Xel_USB interface described in latter part of this manual DMX512 address Xelee output 1 R 2 G 3 B 4 W 2 2 2 Autoaddressing By default all Xelee devices are set to work on the same DMX512 addresses Autoaddressing mode enables quick configuration allowing the devices to operate at higher DMX512 addresses In this mode of operation there is no need to configure each device separately Configuration of autoaddressing mode will cause devices to choose other addresses automatically If this feature is turned on for a driver the devices connected to it s output will switch to higher addresses Group I address 1 4 Group II address 5 8 bes el seal es fesl booo Kell DOC Pood Xelee driver autoaddresing OFF Xelee driver Xelee driver Xelee driver autoaddresing autoaddresing autoaddresing OFF OFF ON a m RR E A DMX512 o Signal Patchcord UTP cat 5e DMX512 Signal CAUTION Using autoaddressing feature is reccomended only for daisy chain topolgy of Xelee drivers network www nelectrica com page 8 XELEE PowerLED Driver User Manual 2 2 3 Micro switch configuration Xelee driver has two micro switches allowing the change of autoaddressing mode and bus
7. XELEE PowerLED Driver User Manual Xelee PowerLED Driver User Manual page 1 www nelectrica com XELEE PowerLED Driver User Manual Contents 1 Overview 2 DMX receiver operation 2 1 Creating devices network 2 1 1 DaiSy Chain opology NENNEN 5 Z dice BUS e eil Le LEE 6 ZA S Mied ODOIOGY EE 7 2 2 Configuration 2 2 A Address gue EE 8 EE EE EE ee S A 8 2 2 3 Micro Switch configuration NENNEN 9 2 2 Configuration USING EE 9 3 Independent driver operation Deb VIG SI OWS EE 10 3 2 Controling other Xele devices kk NK RRKK REN NK NENNEN KENNEN REN REN 11 4 Installation A Le Gelee In E 12 AZ LEDUS EE 13 4 3 Connecting LED MOGUICS EE 13 44 EE 14 5 Connecting accessories E Xe Mal SWIGCM EE 15 5 ZIR reMO O sect cctoceretcnai E 15 www nelectrica com page 2 XELEE PowerLED Driver User Manual 1 Overwiev Xelee PowerLED is a multichannel driver designed to drive most of the market available high power LED modules Integrated logics allow light scenes and shows generation with no need for additional controllers Each LED output can be dimmed independently resulting in millions of high saturated or pastel colors in RGB RGBW lighting systems High output resolution makes color changes incredibly smooth and light shows extremely dynamic Features standard light switch or IR remote control 350mA to 700mA constant current LED outputs high output refresh rate
8. by devices other than Xelee drivers All receiving Xelee devices will respond the same way even if their address settings are different The only important configuration step is enabling bus termination depending on the network topology used Xelee driver master IR sensor or external switch Patchcord UTP cat 5e RJ 45 passive splitter 50909 JOL DOT Us Usel Fe RIES JOGL HL www nelectrica com page 11 XELEE PowerLED Driver User Manual 4 Installation 4 1 Front panel DMX PW IR CH DMX512 LED LED DMX512 IR SW IN OU LED PA eor fl E ll OO A _ LT ADR JTERM _ a SW SW DC IN DC IN power supply connection DMX512 IR SW IN DMX512 signal input external switch or IR remote receiver DMX512 OUT DMX512 output DMX512 IR SW IN PWR LED power supply indicator 1 DMX512 DATA IN 2 DMX512 DATA IN 3 External switch 4 External switch IR receiver GND 5 6 7 8 IR receiver 1 IR receiver 2 DMX512 COMMON DMX512 COMMON ADR LED autoaddressing mode indicator IR CH LED IR channel indicator DMX LED DMX512 input indicator ADR SW autoaddressing configuration TERM SW bus termination configration DMX512 OUT 1 DMX512 DATA OUT 2 DMX512 DATA OUT 3 not used 4 not used 5 6 7 8 not used not used DMX512 COMMON DMX512 COMMON www nelectrica com
9. page 12 XELEE PowerLED Driver User Manual 4 2 LED outputs PUT EENE NN ANN i EEN eege LED outputs W R G B depending on the hardware configuration 1 4 channels assigned to LED colors LED current of 350 500 700 or 1000 mA available XeLED output for easy LED modules connection with single RJ 45 plug XeLED 1 Green 2 Blue 3 Blue 4 Green 5 White 6 Red 7 Red 8 White 4 3 Connecting LED modules Xelee driver LED outputs allow serial connection of high power LED modules For correct light scene generation in RGB RGBW version diodes with certain color should be connected to proper output R red G green B Blue W white CAUTION Standard outputs and XeLED output are in parallel connection allowing the use of only one output type at time www nelectrica com page 13 XELEE PowerLED Driver User Manual Driver s supply voltage should be at least 3V higher than the highest total forward voltage of single LED series Maximum supply voltage is 32V The current output of power supply needed for correct operation can be calculated by adding the output channels currents with addition of 20 spare Example Xelee outputs configuration XEL RPLD 0379 channel 1 350 mA channel 2 350 mA channel 3 700 mA channel 4 1000 mA Required power supply current output 350 350 700 700 120 2520 mA
10. ransmission causes the outputs to freeze on the last received values Operation DMX512 input signal Response Switching power ON not present Light show presentatnion Switching power ON present DMX512 receiver operation Light show presentatnion not present Light show presentatnion Light show presentatnion present DMX512 receiver operation DMX512 receiver operation not present Freeze on the last values DMX512 receiver operation present DMX512 receiver operation CAUTION Returnig from receiver operation to light show presentation requires turning off and on the power supply or sending the reset command from Xelee Programmer PC application The control over light shows is possible with external switch or additional IR remote At any time during the show Xelee device outputs can be switched off without switching off the power supply In this mode supply current is lower than 30 mA Light show settings are saved during external switch or IR remote shutdown and reloaded even after the power supply restart Detailed information on external switch and IR remote control can be found in Xelee devices control document www nelectrica com page 10 XELEE PowerLED Driver User Manual 3 2 Controlling other Xelee devices In light shows mode Xelee device sends the output brightness levels for other devices through DMX512 output Data is sent using modified DMX512 protocol and will not be received
11. tput allowing connection of additional devices DMX512 DMX DMX512 Input LED Output For quick lighting system diagnostic DMX512 signal reception is indicated by green DMX LED 2 1 Creating devices network 2 1 1 Daisy chain topology A larger lighting system can be built using Xelee drivers connected in daisy chain In this type of topology each device s DMX512 input is connected to previous device s output The biggest advantage of this type connection is signal regeneration by each device in chain Soo pocol DEI IL Xelee Xelee driver driver terminator ON BEBE terminator ON E Signal page 5 www nelectrica com XELEE PowerLED Driver User Manual The connections between devices can be done with UTP cable of at least 5e category with both ends fixed with RJ 45 plugs Both plugs should be fixed using the same T 568A or 1 568B standard Maximum cable length is 300m Xelee device built in terminator should be turned ON with the TERM SW switch 2 1 2 Bus topology Connecting devices in bus topology means that all devices inputs are connected to common control bus The connections are made with the same cable as for the daisy chain and RJ 45 passive splitters Maximum bus length for cat 5e cable is 300m Single bus can hold up to 32 devices Connecting more devices can be done after regenerating the signal with dedicated DMX512 repeater or single Xelee device The last driver connected to

Download Pdf Manuals

image

Related Search

Related Contents

Samsung 32" nõgusa ekraani ja värvilise  Liste des pièces de rechange Pica II  POSC/EIA/56646/2004 - HASLab  ICIDU USB 2.0 HUB 7 Ports  XM-1505SX - hifi  Télécharger en PDF  Guide Utilisateur Apicrypt  Burglar Alarm System  Viewsonic Professional Series VP231WB  file PDF - ANNUARIO della SICUREZZA OnLine  