Contents

1. AriogziN 8sT E 250 9 84 Unit mm inch 1 When connecting the twisted pair cable make the bend radius R1 scale value in the vicinity of the connector to cable outside diameter x 4 or more 2 When connecting the AUI cable make the bend radius R2 Scale value in the vicinity of the connector to cable outside diameter x 4 or more 3 The external dimension diagram of the AJ71QE71N B2 is the same as AJ71QE71N B5T except interface unit The following shows the external dimension diagram of the interface unit 4 2 l 106 0 17 4 17 2 A1SJ71QE71N B5T A isu710 71N 85T RUN OO BUF1 130 EXT PW A1SJ71QE71N B5T 6 5 93 6 75 34 5 0 26 3 69 0 30 1 36 Unit mm inch 1 When connecting the twisted pair cable make the bend radius R1 scale value in the vicinity of the connector to cable outside diameter x 4 or more 2 When connecting the AUI cable make the bend radius R2 Scale value in the vicinity of the connector to cable outside diameter x 4 or more 3 The external dimension diagram of the A1SJ71QE71N B2 is the same as A1SJ71QE71N B5T except interface unit The following shows the external dimension diagram of the interface unit 6 5 93 6
2. l 0 26 3 69 Ethernet is the registered trademark of XEROX CO LTD 10BASE2 is the formal way to say Cheapernet There is no registered trademark for Cheapernet 12 Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi machine damage or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties NFor safe use This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi This product has been manufactured under strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system Country Region Sales office Tel Country Region Sales office Tel U S A Mitsubishi Electric Automation Inc China Ryoden International Shanghai Ltd 500 Corporate Woods Parkway Vernon 3F Block5 Building Automation Hills IL 60061 Instrumentation Plaza 103 Cao Bao Rd Tel 1 847 478 2100 Shangh
3. module may cause a malfunction or damage to the module or cable e Solder coaxial cable connectors properly Insufficient soldering may cause malfunction e Be sure that cuttings wire chips or other foreign matter do not enter the module Foreign matter may start a fire or cause an accident or erroneous operation A 3 Revisions The manual number is given on the bottom left of the back cover Print Date Manual Number Mar 2002 IB NA 0800182 A First printing This manual confers no industrial property rights or any rights of any other kind nor does it confer any patent licenses Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contenis noted in this manual 2002 MITSUBISHI ELECTRIC CORPORATION A 4 AOUN CONTENTS ONIE PVEN E AA E EE EEE EE PE PAE IEE IREE E M EE e 1 Pertormarce Specifications irn aaa E E E 2 Settings and Names of Each Pa es racer o Ebr px ete ede Ge gu pa 4 Loading afid Installaloris s sans eio io e e mU ND dr ud Re 8 4 1 Handling Precdullolis a 2 ceases Pb PERO a week a ria a a esl te totem 8 4 2 Installation Environment cuir rie eoe REED E EAE E EE DO IRE UU ito cee alicia tec 8 Connection to a NODWOEK oec er deerat ie hein ieee eo sani b eben LL 9 5 1 Connecting to the 10BASE T AJ71QE71N B5T A19J71QE71N B5T 10 5 2 Connecting to the 10BASE5 A
4. 1N B5T A 2710871N B2 A 1su710 71N 85T Avian RUN DO BUF1 RUN O O BUF1 RDY O O BUF2 RDY O O BUF2 BSY O BUF3 SW ERR O O BUF4 TE TEST ERR O BUF7 CPU RW DO Burg O ONLINE 1 OFFLINE TEST A1SJ71QE71N B5T only EXT PW A1SJ71QE71N B5T For A1SJ71QE71N B5T No Designation Contents Display LED Refer to 1 Operation mode setting Refer to 2 switch setting switch ET Lamp for verifying if power is being supplied to the transceiver when used as 10BASE5 External power supply ON Power supplying indicator lamp OFF Power not supplied When connecting with 10BASE T verification is unnecessary Power source terminals for power source supply to the transceiver in the connection of 10BASES 14 08 V to 15 75 V When connecting with 10BASE T verification is unnecessary Connector for connecting the QE71 to the 10BASE5 AUI cable connector For connection of 10BASE5 use AUI cable transceiver cable 10BASE2 connector Connector for connecting the QE71 to the 10BASE2 1 Display LED display contents Display LED Display contents When lamp is lit Lamp is not lit Noria operatien dizplay por sonore SaR T CNN a display with remote node is being executed CPURW R W External power supply terminal T E process
5. Connecting to the 10BASE T AJ71QE71N B5T A1SJ71QE71N B5T lt Connection procedure gt 1 Connect the twisted pair cable and the hub 2 Connect the twisted pair cable to the QE71 For AJ71QE71N B5T 5 2 Connecting to the 10BASE5 AJ71QE71N B5T A1SJ71QE71N B5T Supply power Connection procedure 1 for transceiver 1 Slide the retainer toward the direction A as shown in the figure AUI Cable 2 Push in the AUI cable connector all the Way POCAS Host 3 Slide the retainer toward the direction B as shown in the figure B 4 Confirm that the AUI cable is locked 5 Supply power to the transceiver 7 2 Refer to 3 in Chapter 2 Retainer 1 Connect the AUI cable while the power to the module mounting station is turned off 2 Use a transceiver with a function that is generally called SQETEST or heart beat a transceiver function that emits signals to notify whether the transceiver is operating normally at the end of communication 5 3 Connecting to the 10BASE2 AJ71QE71N B2 A1SJ71QE71N B2 Connection procedure 2 1 Push in the connector by aligning the groove 1 and tab 2 as shown in the figure 2 While pushing in the connector rotate it clockwise by a 1 4 turn 3 Turn until the connector locks 2 4 Confirm that the connector is locked For AJ71QE71N B2 10 6 External Dimensions 1 AJ71QE71N B5T_
6. J71QE71N B5T A1SJ71QE71N B5T 10 5 3 Connecting to the 10BASE2 AJ71QE71N B2 A1SJ71QE71N B2 10 External DIMENSIONS sao edomonecon eite pesi dad didi did nda 11 A 5 About the Manuals The following product are available for this equipment Refer to the table given below to choose suitable manuals Detailed Manual Manual name Manual No Model code SH 080146 For QnA Ethernet Interface Module User s Manual 13JR33 Model code When read write data exchange in the PLC CPU is performed with the E71 commands either of the following manual is required SH 3598 Manual for AJ71E71 S3 A1SJ71E71 B5 S3 A1SJ71E71 B2 S3 SH 080192 Manual for AJ71E71N B5T AJ71E71N B2 A1SJ71E71N B5T A1SJ71E71N B2 Conformation to the EMC Directive and Low Voltage Instruction For details on making Mitsubishi PLC conform to the EMC directive and low voltage instruction when installing it in your product please refer to Chapter 3 EMC Directive and Low Voltage Instruction of the User s Manual Hardware for the CPU module to use The CE logo is printed on the rating plate on the main body of the PLC that conforms to the EMC directive and low voltage instruction For information about conforming this product to the EMC directive and low voltage instruction please refer to Chapter 3 EMC Directive and low Voltage Instruction section 3 1 3 Cable of the User s Manual Hardware for the CPU mod
7. MITSUBISHI For QnA Ethernet Interface Module User s Manual Installation AJ71QE71N B5T A1SJ71QE71N B5T AJ71QE71N B2 A1SJ71QE71N B2 Thank you for buying the Mitsubishi general purpose programmable logic controller MELSEC QnA Series Prior to use please read both this manual and detailed manual thoroughly and familiarize yourself with the product MODEL QE71N U HW MODEL MERTE IB NA 0800182 A 0203 MEE 2002 MITSUBISHI ELECTRIC CORPORATION e SAFETY PRECAUTIONS 6 Always read before starting use When using Mitsubishi equipment thoroughly read this manual and the associated manuals introduced in the manual Also pay careful attention to safety and handle the module properly These precautions apply only to the installation of Mitsubishi equipment and the wiring with the external device Refer to the user s manual of the CPU module to be used for a description of the PLC system safety precautions These e SAFETY PRECAUTIONS e classify the safety precautions into two categories DANGER and CAUTION Pa LII LAE LE TS Procedures which may lead to a dangerous condition and cause DANGER death or serious injury if not carried out properly Procedures which may lead to a dangerous condition and cause NCAUTION superficial to medium injury or physical damage only if not carried out properly Depending on circumstances procedures indicated by NCAUTION may also be linked to serious
8. ai 200233 China Brazil MELCO TEC Rep Com e Assessoria Tel 486 21 6475 3228 M PE eins Taiwan Setsuyo Enterprise Co Ltd v Mio Branco qto an 6F No 105 Wu K 3rd RD Wu K Rio de Janeiro RJ CEP 20040 005 E ieee PES Hsiang Taipei Hsine Taiwan Brazil YA Tel 455 21 221 8343 Tel 886 2 2299 2499 n Korea HAN NEUNG TECHNO CO LTD Germany ae Electric Europe B V German 1F Dong Seo Game Channel Bldg Gothaer Strasse 8 D 40880 Ratingen RR T Deungehon dang Kangsec Ku GERMANY eoul Korea Tel 449 2102 486 0 Tel 82 2 3668 6567 ee teat Singapore Mitsubishi Electric Asia Pte Ltd U K HU Electric Europe B V UK 307 ALEXANDRA ROAD 05 01 02 MITSUBISHI ELECTRIC BUILDING Travellers Lane Hatfield Herts AL10 8XB UK SINGAPORE 159943 Tel 444 1707 276100 Spin A dal den Ital Mitsubishi Electric E B V Itali aran E eae tay ces L ecte ENP ees OBSS 898 28 29 30 S V City Building Office Centro Dir Colleoni Pal Perseo Ingr 2 as er Dor d Rama 3 Road Via Paracelso 12 20041 Agrate B angkpongpang yannawa Milano Italy Bangkok 10120 Tel 39 039 60531 Pelee cue DSE Spain Mitsubishi Electric Europe B V Spanish Indonesia P T Autoteknindo SUMBER MAKMUR Branch Carretera de Rubi 76 80 Jl Muara Karang Selatan Block A Utara 08190 Sant Cugat del Valles No 1 Kav No 11 Kawasan Industri Barcelona Spain i Pergudangan Jakarta Utara 14440 Tel 34 935 653135 e a E South Africa Circuit Breaker Industries LTD India Messu
9. des Communications Settin exchange condition Switch 9 Setting contents designation setting switch Li Selects the line processing when the TCP Ine Processing ULP time out error occurrence 951 c E exchanging data with the remote node RE Smet exchange in binary code ON Conducts emen MET d in ASCII code Seld the QE71 Select the QE71 startup method method OFF Runs following Y19 initial processing request signal Reads the parameters in the EEPROM buffer memory regardless of the Y19 after power has been turned on or the module reset and then conducts initial processing of the contents Data code setting Automatic start up mode setting Self start mode setting Usage not possible Fixed to OFF Selects whether to approve or forbid data CPU exchange arriving from the remote node when a PLC CPU is running Ng SERRO Writing prohibited ON Writing approved Selects the initial processing starts up timing 72 Quick start starts without a delay t OFF time Set when one network is Initial timing used for the entire configuration setting Normal start start after a delay of 20 seconds Use when the entire ON configurations is made up of multiple networks This is set at OFF at the time of shipping from factory 1 Set to OFF for normal use When a TCP ULP time out error error code CO32H occurs due to data transfer from remote node while this switch is set to ON run the cl
10. essing of connection cable trunk line cable etc please consult with a trained professional 2 When the customer s products match the EMC instructions and the low voltage instructions for connecting QE71 use the method in 4 below to install the ferrite core 3 When there is a communication error caused by high frequency noise due to the installation environment take the following steps e The ferrite core can be installed using the steps in 4 below e When communicating with TCP IP increase the count of communication retries e When connecting to 10 BASE T use an unshield twisted pair cable UTP category 5 e When connecting to 10BASE2 use a double shielded coaxial cable e When connecting to 10BASES5 or 10BASE2 ground the shield of the coaxial cable at both the local station and companion connected device Ground at a place near the connector 4 Below are the steps for installing the ferrite core based on connection to the 10BASE5 network Please install the ferrite core 1 on the side of the QE71 or external devices the AUI cables transceiver 1 It is possible to use a TDK Corporation style ZCAT 2032 0930 For 10BASE5 connection Ferrite core Jf EMEN cable for 1OBASE5 Transceiver 5 When using A1SJ71QE71N B5T when the FG signal is regulated on the side of the external power supply of the original power supply for the transceiver ground the FG signal at the original power supply 5 1
11. ing executing orurw Oe PLC CPU oe cad E Display of communication line BUF1 to BUF8 connection status of connection Open completed Closed status No n corresponding to BUFn TEST Self diagnostic executing display Self diagnostic executing display executing display SEI diagnosis Ser diagnosis executing completed LONE ERR Self diagnosis results display Normal sid Exchanging Not exchanging The order of the display LEDs is shown below AJ71QE71N B5T AJ71QE71N B2 A1SJ71QE71N B5T A1SJ71QE71N B2 RUN ri ri BUFI RUN O O BUFI O O BUF2 RDY o BUF2 RDY S o Por BSY o oF BUF3 EY SW ERR O O BUF4 Cena o a COM ERR O O BUF5 CPUR W O O BUF7 TEST O BUF6 E TEST ERR r1 O BUF7 ae CPU RWO r3 BUF8 O O O O O O TEST O O TEST ERR O O O O 2 Operation mode setting switch setting Set the QE71 operation mode Usually set to on line Operation mode Setting Setting Setting contents setting switch number designation Performs exchange with remote node in the On line normal operation mode Off line Disconnects the local station from the network Performs a self diagnosis test using a self Performs a RAM test Performs a ROM test Performs an EEPROM test Usagenotimpossible 6toF Usage not impossible This is set at O on line at the time of shipping from factory Communications exchange condition setting switch setting ee the conditions for data communication with other no
12. ng Systems Put Ltd 1 Private Bag 2016 Isando 1600 Electronic Sadan NO 111 Unit No15 Johannesburg South Africa M I D C BHOSARI PUNE 411026 Tel 427 11 928 2000 Tel 91 20 7128927 Hong Kong Ryoden Automation Ltd Australia Mitsubishi Electric Australia Pty Ltd 10th Floor Manulife Tower 169 Electric 348 Victoria Road PostalBag No 2 Road North Point HongKong Rydalmere N S W 2116 Australia Tel 852 2887 8870 Tel 461 2 9684 7777 MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE 1 8 12 OFFICE TOWER Z 14F HARUMI CHUO KU 104 6212 JAPAN NAGOYA WORKS 1 14 YADA MINAMI5 HIGASHI KU NAGOYA JAPAN Specifications subject to change without notice Printed in Japan on recycled paper
13. ose and open operations with the sequence program 2 Set to OFF for normal use 4 Loading and Installation The following is explanations of the handling precautions and installation environment which is common to modules when handling QE71 from unpacking to installation For the details of loading and installation of the module refer to Users Manual of CPU module to be used 4 1 Handling Precautions The following is an explanation of handling precautions of the module 1 Because the case of the module is made of resin be careful not to drop it or expose it to strong impact 2 Execute tightening of the module s installation screws within the range indicated below Tightening torque range Screw position AJ71QE71N A1SJ71 AN n ee Se A eee BST screw 1 M4 screw M2 5s screw 78 to 118 N cm M4 screw 1 This terminal is used as an external power input terminal for supplying power to the transceiver when being connected to a 10BASES Input of external power to the external power supply terminal is not required when being connected to a 10BASE T Module fixing screw 4 2 Installation Environment Refer to User s Manual of CPU module to be used 5 Connection to a Network The following is an explanation of the connection method of the QE71 to the 10BASE T 10BASE5 or the 10BASE2 1 Installation procedures of the network require sufficient safety measures For the execution of such operations as terminal proc
14. ou do not switch off the external power supply it will cause electric shock or damage to the product e Do not touch the electronic parts or the module conducting area directly It may cause erroneous operation or failure A 2 WIRING PRECAUTIONS CAUTION Perform correct pressure displacement crimp contact or soldering for external wire connections using the tools specified by the manufactures Incorrect connection may cause short circuits fire or malfunction Attach connector to the module securely e Be sure to fix communication cables or power supply cables leading from the module by placing them in the duct or clamping them Cables not placed in the duct or without clamping may hang or shift alllowing them to be accidentally pulled which may cause a module malfunction and cable damage e Tighten the screw within the range of specified torque If the screws are loose it may result in short circuits or malfunction Tightening the screws to far may cause damage to the screw and or the module resulting in fallout short circuits or malfunction Do not grab on the cable when removing the communication cable connected to the module When removing the cable with a connector hold the connector on the side that is connected to the module When removing the cable connected to the terminal block first loosen the screws on the part that is connected to the terminal block Pulling the cable that is still connected to the
15. rent A1SJ71QE71N B2 0 64A A1SJ71QE71N B5T 0 42A 12 V DC external power supply capacit AJ71QE71N B2 AJ71QE71N B5T 250 9 8 H x 37 5 1 5 W x 106 4 2 D mm inch 4 A1SJ71QE71N B2 A1SJ71QE71N B5T AJ71QE71N B2 Mags AJ71QE71N B5T A1SJ71QE71N B2 A1SJ71QE71N B5T 0 D sub connector Modular jack Coaxial Cable Un shield twisted AUI cable Cable RG58A U pair cable UTP b ue pair cable Ras8C U category 3 4 5 1 Length between hub and node 2 I O assignment should be set by special 32 points when performed with GX Developer 3 lt is required to use that which satisfies the specifications of the transceiver and the AUI cable considering the voltage drop in QE71 Maximum 0 8 V 4 The protuberance of QE71 is not included in the dimensions External dimensions 1 Each item in the transmission specifications gives supplementary explanation eWhen connected by 10BASE2 10BASE5 Segment length Maximum distance between nodes Segment length Segment length When connected by 10BASE T E T L1 C Hub 90000000 Maximum 100 m 328 1 ft Cascade connection is a maximum of 4 stages 4 0000000 A F SAna 20000006 Maximum 100 m 328 1 ft 2 Hardware specifications for QE71 are based on IEEE802 3 3 Settings and Names of Each Part AJ71QE71N BST AJ71QE71N B2 A s71067
16. results In any case it is important to follow the directions for usage Store this manual in a safe place so that you can take it out and read it whenever necessary Always forward it to the end user A 1 DESIGN PRECAUTIONS CAUTION When laying the control wire or communication cable do not bundle with or place near main circuit or power line Keep them at least 100 mm 3 94 in away from such cables Noise may cause erroneous operation INSTALLATION PRECAUTIONS CAUTION Use the PLC in the environment given in the general specifications section of the user s manual to be used Using the PLC outside the range of the general specifications may result in electric shock fire or erroneous operation or may damage or degrade the product Install so that the tabs at the bottom of the module fit securely into the base unit mounting holes The Q2AS series module shall be fastened by screws in the base unit at the specified torque Not installing the module correctly could result in erroneous operation damage or pieces of the product falling e Tighten the screw within the range of specified torque If the screws are loose it may result in fallout short circuits or malfunction Tightening the screws to far may cause damage to the screw and or the module resulting in fallout short circuits or malfunction Make sure to switch all phases of the external power supply off before mounting or removing the module If y
17. ule to use A 6 1 Overview This manual explains how to install the following Ethernet interface modules abbreviated as QE71 hereafter for QnA series PLC CPU and how to wire them with external devices After unpacking QE71 verify that the following parts are contained FAJTIQE7IN B2Qype Ethernet Interface Module 1 AJ71QE71N B2 AJ71QE71N B2 type Ethernet Interface Module F type Connector AGRCON F 1 AJ71QE71N B5T AJ71QE71N B5T type Ethernet Interface Module 1 A1SJ71QE71N B2 type Ethernet Interface Module MSJ7IOE7IN Bo LA 19J7 1 QE71N B2 type Ethernet Interface Module A1SJ71QE71N B5T A1SJ71QE71N B5T type Ethernet Interface Module 1 2 Performance Specifications The performance specifications of QE71 is shown below See CPU module user s manual to be used for QE71 general specifications Topic P TOBASES 10BASE2 10BASE T speed Transmission Base band method Maximum distance 2500 m specifications Menu 500 m 1640 42 ft 185 m 606 96 ft ponen segment length 1 T number 100 nodes per 30 nodes per c 5 segment segment connection maximum 4 stages Minimum distance 2 5 m 8 20 ft 0 5 m 1 64 ft between nodes Possible number open simultaneously 8 connections Sending receiving communication possible number open from QnACPU Q2AS H CPU data memory for storage Number of input output power 32 points 32 points P AJ71QE71N B2 0 56A 5 V DC internal consumption AJ71QE71N B5T 0 48A cur