Home
User manual - CyberPower
Contents
1. 0009 www cpsww com CyberPower Systems EUROPE Inc Flight Forum 3545 5657DW Eindhoven The Netherlands E mail sales cyberpower eu com eu cyberpowersystems com CyberPower Reliability Quality Value K01 2712002 01
2. Elevation 50 000ft 15 000m Storage Temperature 4 F 113 F 20 C 45 C LIMITED WARRANTY CyberPower warrants to you the Initial Purchaser that the Product will be free from defects in material and workmanship for three years from the date of original purchase subject to the terms of this Limited Warranty This Limited Warranty gives you specific rights and you may have other rights which vary from State to State or Province to Province Any Implied Warranty of Merchantability or for Fitness for a Particular Purpose if applicable to the Product is limited in duration to three years This provision shall NOT create any Implied Warranty or Merchantability or of Fitness for a Particular Purpose that would not otherwise apply to the Product NOTE Some States and Provinces do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you To be covered you must still be the owner of the Product at the time of the failure that results in the claim made under this Limited Warranty Your sole and exclusive remedies are those provided by this Limited Warranty This exclusion of other express warranties applies to written and oral express warranties CyberPower excludes any liability for personal injury CyberPower excludes any liability for direct indirect special incidental or consequential damages whether for damage to or loss of property loss of profits business interruption information
3. are designed to provide a local power solution for cable telephony wireless local loop WLL and fiber to the home FTTH broadband equipment IMPORTANT SAFETY WARNINGS SAVE THESE INSTRUCTIONS This manual contains important instructions regarding the installation and operation of this device Read this manual thoroughly before attempting to unpack install or operate this device CAUTION The battery can energize hazardous live parts inside even when the AC input power is disconnected CAUTION To prevent the risk of fire or electric shock install in a temperature and humidity controlled indoor area free of conductive contaminants Please see specifications for acceptable temperature and humidity range CAUTION To reduce the risk of electric shock do not remove the cover except to service the battery No user serviceable parts inside except for the battery CAUTION To avoid electric shock turn off the unit and unplug it from the AC power source before servicing the battery or installing a computer component CAUTION When replacing batteries the replacement should have the same rating as follows Listed Certified Valve Regulated Lead Acid Battery 12V max 9Ah CAUTION Risk of Energy Hazard 12V max 9 Ampere hour battery Before replacing batteries remove conductive jewelry such as chains wrist watches and rings High energy through conductive materials could cause severe burns CAUTION Do not dispose of batteri
4. or data This exclusion applies even though damage or loss is caused by negligence or other fault NOTE Some States or Provinces do not allow the exclusion or limitation of incidental or consequential damages so the above limitation may not apply to you DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT OR OTHER HIGH RISK ACTIVITIES CyberPower does not sell the PRODUCT for use in high risk activities The PRODUCT is not designed or intended for use in hazardous environments requiring fail safe performance including the operation of nuclear facilities aircraft navigation or communication systems air traffic control weapons systems life support or medical applications or for use in any circumstance in which the failure of the PRODUCT could lead directly to death personal injury or severe physical or property damage or that would affect operation or safety of any medical or life support device collectively High Risk Activities CyberPower expressly disclaims any express or implied warranty of fitness for High Risk Activities CyberPower does not authorize use of any PRODUCT in any High Risk activities ANY SUCH USE IS IMPROPER AND IS A MISUSE OF A CYBERPOWER PRODUCT The Limited Warranty is governed by the laws of the United States and the State of Minnesota without reference to conflict of law principles The application of the United Nations Convention of Contracts for the International Sale of Goods is expressly excluded FCC NOTICE This
5. CyberPower User s Manual for CyberShield CSN27U12V ENCLOSURE INSTALLATION Carefully follow these instructions during installation of this device 1 Carry out the installation in a safe area that is free of excessive dust and has adequate airflow 2 Screws must be appropriate for total weight of the UPS and the mounting surface material 3 Do not operate the UPS where the temperature and humidity are outside the specified limits Refer to specification in this manual CSN27U12V Step 1 Step 2 Step 3 a Remove the battery cover a Slide battery off of the a Use the enclosed installation template to shelf mark an installation location for the unit b Disconnect battery cable b Mount the unit on the wall with 2 mounting connector at chassis end screws into the keyhole slots c Tighten the screws to secure the units d Connect the battery connector and replace the battery back Note please always mount the unit on the wall when it is working BATTERY REPLACEMENT This battery is hot swappable As long as utility power is on you may leave the UPS and connected equipment on while replacing a new battery CSN27U12V Step 1 Step 2 Step 3 a Remove the battery cover a Disconnect battery cable connector a Make sure battery is fixed properly to remove battery in the compartment and close b Replace with new battery and the battery cover re connect the battery connector CyberShield UPSs
6. enabled Once the battery is disconnected the connected equipment is not protected from power outages eo Deliver spent batteries to a recycling facility or ship to the manufacturer in the replacement battery packing material Pb WARNING INDICATOR Indicator Color Condition SYSTEM Green Indicates normal mode of operation STATUS Green Indicates the battery is supplying the power At 45 battery capacity DC the LED will flash and then alarm will beep 4 times per minute X Orange Press and hold the button Alarm Silence for 0 5 second to silence the audible alarm for 24 hours and the LED will flash Red Battery replacement required Alarm will beep once every 15 minutes REPLACE The LED also illuminates when battery is absent BATTERY COMMUNICATION SIGNALS SPECIFICATION The communication signals of this unit are isolated from the internal circuitry via open collector opto coupled transistors The connection SIG RTN Signal Return is a common CSN27U12V return point for all communication signals In the typical application the attached equipment Input digital ground connects to Signal Return and pull up resistors turn the open collector signals into logic levels Voltage Range 90Vac 264Vac Universal Input Frequency Range 47 10 Hz Output Batt tput Volt 12V Communication signals on a ery Output Vo age a C
7. equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with these instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures 1 Reorient or relocate the receiving antenna 2 Increase the separation between the equipment and receiver 3 Connect the equipment into an outlet on a circuit different from that to which the receiver is connected 4 Consult the dealer or an experienced radio TV technician for help CAUTION Shielded signal cables must be used with this device to ensure compliance with Class B FCC limits CAUTION Any changes or modifications not expressly approved by Cyber Power could void the authority granted by the FCC to operate this equipment For more information please contact CyberPower Systems USA Inc 4241 12th Avenue East Suite 400 Shakopee MN55379 Phone 952 403 9500 Fax 952 403
8. es in a fire The batteries may explode CAUTION Do not open or mutilate batteries Released material is harmful to the skin and eyes It may be toxic OPERATION Connect equipment and power Step1 Plug the UPS power cord into the utility power cord inlet Step2 Plug the UPS power cord into the wall outlet The UPS battery charges when it is connected to utility power The battery charges fully during the first 24 hours of normal operation Do not expect full battery run capability during this initial charge period BATTERY EMERGENCY USE COLD START BC1 OPTION The Battery Emergency Use feature allows emergency reserve time available in the battery to be utilized for 911 or emergency calls providing additional talk time depending on use and conditions The cold start feature is for applying power to the UPS and connected equipment when the UPS is off and there is no utility power Before using the cold start feature please make sure the battery is charged To start the cold start feature press the cold start button on the upper left corner of the unit ALARM SILENCE The audible alarm will be enabled when the unit is operating from battery or battery power is low Press the button for 3 seconds to disable or enable the audible alarm The unit will beep once confirming that audible alarms have been disabled Press this button a second time to enable audible alarms The unit will beep twice confirming that audible alarms have been
9. ontinuous Power Capability 21W CSN27U12V Output Power Max 30W lt 5 sec Efficiency at 75 Max Load 2 80 AC Inlet for 2 pin or 3 pin Battery Battery Type Sealed Maintenance Free Lead Acid Battery Numbers of Battery 7 2AH 12V x 1 Typical Recharge Time 14 Hours 90 charged CSN27U12V Message Replaceable Yes Surge Protection and Filtering 12V Votage ouiput Lightning Surge Protection Yes 12V RTN Voltage output 5 3 SIG RTN Signal retum vaming Seea ON BATTERY Low when operating from utility line Indicators System Status DC Mute Replace Battery Open when operating from battery Management REPLACE Low when battery is charged Auto Charge Yes BATTERY Openiwhen battery fails the Self Test Communication Interface On Battery Replace Battery Battery Missing BATTERY Low when battery is present Low Batt MISSING Open when battery is missing ON BSNS LOW BATTERY Low when battery is near full charge capacity Physical Open when operating from a battery with lt 20 capacity Maximum Dimensions L W D 16 7cm x 19 cm x 8 3 cm Weight kg 3 03 Environment AUXILIARY POWER SOURCE Operating Temperature 4 F 113 F 20 C 45 C When connecting the UPS to an auxiliary power source please use a listed Valve Operating Humidity 0 95 noncondensing within enclosure Regulated Lead Acid Battery with 12Vdc output voltage Using a battery with incorrect Max Operating Elevation 10 000ft 3 000m voltage may cause tisk ot ener hazard Max Storage