Industrial Door Automated Installation Instructions

image

Contents

1. Glidermatic Commercial Door Operator Zh Glidermatic F Commercial Door Operator GLIDEROL GARAGE DOORS Important Safety Instructions DO NOT operate unless the door is completely visible and clear of obstructions including children persons vehicles or other objects SEVERE PERSONAL INJURY property damage or even DEATH may result if this warning is not followed DO NOT operate the door if children or persons are near the opening Children must always be supervised when near the door at all times the operator is In use DO NOT allow children to operate the door SEVERE PERSONAL INJURY property damage or even DEATH may result if this warning is not followed The SAFETY REVERSING function should be tested on a monthly basis to ensure it is set correctly and the door will reverse on its downward motion when an obstruction is encountered If this function does not operate DISCONTINUE USE and contact a qualified service technician If additional SAFETY is required it is STRONGLY recommended that a Photo Electric Cell or Sensing Edge device be installed It is mandatory that such devices be used in conjunction with radio control units or when momentary contact on close function is enabled When the Automatic Close function or Radio Transmitters are being used a Sensing Edge or Photo Electric Cell must be correctly fitted and tested on a regular basis If SAFETY features do not operate correctly DISCONTINUE
2. The cams are driven by a gear mechanism and activate a limit switch at the desired position e The inner cam determines the closed position e The outer cam determines the open position To adjust e Set door to manual operation using the manual release lever Refer to Manual Operation e Remove the cam gear cover on the drive unit to gain access to the internal cams e Loosen cam gear screws x3 4 Closing inner cam e To set the closing position manually lower the door to the required closed position observing the direction of rotation of the inner most cam e Rotate the inner cam in the direction observed until it activates the inner limit switch Opening outer cam e To set the opening height manually raise the door to the desired open position ensure the bottom bar is short of contacting the head stop observing the direction of rotation of the outer cam e Rotate the outer cam in the direction observed until it activates the outer limit switch To complete e Tighten the cam gear screws x3 e Return manual release lever to normal position e Carefully move the door in either direction until pin engagement is noted and the unit is locked into position Refer to Manual Operation Care should be taken to ensure the lever arms on the limit switch are not obstructed by the rotation of the gearing CAUTION The motorised travel of the door is directly controlled by the Cam adjustment settings Please ensure the re
3. to unit BEFORE making any setting changes p Edge Peelin sad a 2 yA g bleek Pee gt a Torque Setting 5 j an The Glidermatic operator is designed to stop and reverse it s downward operation if it encounters an obstruction This is set by adjusting JP1 to the lowest current that will allow the door to close during normal operation Start by testing with the jumper JP1 set at 4 If the door will not close proceed testing with JP1 set at 3 Continue setting JP1 until the door will completely close by moving the jumper accordingly The current settings are 1 5 5 amps largest door 2 4 5 amps 3 3 5 amps 4 2 5 amps smallest door The overload function should be tested on a regular monthly basis to ensure the door will reverse on its downward motion when an obstruction is encountered If this function does not operate discontinue use and contact a qualified service technician Glidermatic F Commercial Door Operator GLIDEROL GARAGE DOORS Photo Electric Cell Wiring Consult the installation instructions supplied by manufacturer of the Photo Electric Cell and determine whether the contacts are normally open N O or normally closed N C CAUTION Always disconnect power to unit BEFORE making any setting changes Connect the two wires from the Photo Electric Cell receiver LL O OO E output terminals to the terminals gt 5 O marked PCELL on wiring terminal J5 Lace LL 9 OQ u
4. z Z O If the Photo Electric Cell output uses normally open contacts move jumper on JP5 from OFF to N O oot If the Photo Electric Cell Z Z O output terminals feature normally closed contacts move jumper on JP5 from OFF to N C lro Photo Electric Cells are recommended as a supplementary safety system ar Vianug JS Glidermatic F Commercial Door Operator GLIDEROL GARAGE DOORS Sensing Edge Wiring Consult the installation instructions supplied by manufacturer of the Sensing Edge device and determine whether the contacts are normally open N O or normally closed N C CAUTION Always disconnect power to unit BEFORE making any setting changes Pua 7 Connect the two wires from the Sensing Edge terminals marked EDGE on terminal block J5 N C N O OFF N C N O OFF If the Sensing Edge contacts are normally open move jumper on MP3 from OFF to N O N C N O OFF If the Sensing Edge features normally closed contacts move jumper on JP3 from OFF to N C Sensing Edge devices are recommended as a supplementary safety system Glidermatic F Commercial Door Operator GLIDEROL GARAGE DOORS Radio Control Wiring In order to operate the door with a wireless remote an independent Radio control unit may be installed and connected to the Glidermatic control unit CAUTION Always disconnect power to unit BEFORE making any se
5. E DOORS Handing of the Operator check Setting The Glidermatic Operator may be fitted to either the left hand or right hand side of the door viewed from the inside looking outward However all units as standard factory issue are configured to Right Hand operation If required the direction of operation can be changed by setting jumper JP6 CAUTION Always disconnect power to unit BEFORE making these setting changes i Set jumper JP6 according to whether the operator is installed for Right Hand or Left Hand operation 2 For Right Hand operation RH ensure the jumper is set according diagram JP6 DRIVE 3 For Left Hand operation LH ensure the jumper is set according to diagram JP6 DRIVE Glidermatic F Commercial Door Operator GLIDEROL GARAGE DOORS N Manual Operation In the event of power failure or situations where manual operation of the door is required Manual operation is activated by use of the manual release lever A Manual TT Release Lever When normal operation is required return the lever to the Electric Operation position Engage the spring loaded release pin by carefully moving the door in either direction until pin engagement is noted and the unit is locked in position Glidermatic F Commercial Door Operator GLIDEROL GARAGE DOORS Door Travel Adjustment The door travel is determined by rotation of cams in the drive unit
6. USE and contact a qualified service technician When possible activate the manual release only when the door is closed Weak or broken springs may allow the door to fall rapidly causing SEVERE INJURY or even DEATH In all cases stand clear of the door In the event that the door appears to fall a qualified service technician will be required to adjust the spring tension Install the control unit on the same side of the door as the drive unit with an uninterrupted view of the door and opening The control unit should be installed in a suitable location to ensure it is protected from the elements Under NO CIRCUMSTANCES should the unit be exposed to water When installing the operator on an existing door ensure it is good operating order Ensure the springs are not weak or broken and the door is free of sticking or binding Contact a qualified service technician for attention to any of these issues If any wiring is damaged it MUST BE replaced by a qualified service technician in accordance with the NATIONAL ELECTRIC CODE and the manufacturers detail Ensure the door is completely open before proceeding through the doorway Zh Za GLIDEROL GARAGE DOORS Glidermatic Commercial Door Operator Drive Unit Exploded Parts Diagram oe NN NR NS kk a kk dk OO A ze Low voltage DC motors Main drive gear Geared chain wheel Drum wheel Open and close limit switches 4 Cam Gears Manual release lever Emergency chain h
7. of time up to 12 minutes CAUTION Always disconnect power to unit BEFORE making any setting changes Enable Automatic Close JP4 To enable the Automatic Close Function move Jumper on JP4 A C terminal from OFF to ON 9 Peer Adjust timer Timer can be adjusted using the potentiometer A CLOSE to achieve a maximum time delay of 12 minutes It is essential that a supplementary safety device such as a Sensing Edge or Photo Electric Cell be fitted when the automatic close function is in use to prevent injury or entrapment Glidermatic F Commercial Door Operator GLIDEROL GARAGE DOORS Alarm Function The Glidermatic operator can be connected to a security system to activate an alarm when an attempt is made to open a closed door CAUTION Always disconnect power to unit BEFORE making any setting changes Alarm Wiring A 5 volt DC signal is sent to terminal J4 in the event an attempt is made to force the door open This must drive a 5VDC relay to control any alarm fitted Consult the installation instructions supplied by the manufacturer of the alarm being fitted for connection and relay details
8. oist Chain guide 1 Drive unit plate Adaptor Slip ring bush Manual release switch 3 Anchor bracket Cam cover 6 15 14 This manual refers to settings and connections to be performed on the DRIVE UNIT and CONTROL UNIT not the installation of the door Glidermatic F Commercial Door Operator GLIDEROL GARAGE DOORS Control Unit The CONTROL UNIT is best mounted on the same side as the drive unit with an uninterrupted view of the door It is essential that the CONTROL UNIT be securely fixed to the wall or structure involved through the four mounting holes provided Connect the CONTROL UNIT to a 115 volt single phase AC power source ensuring to follow local wiring codes or National Electric Code where applicable Suitable rigid conduit should be used to protect all wiring and be securely fixed Ensure the unit is properly grounded using the grounding post green lead in the splice connection area Splice connection area Hole for Connect control pendant to terminal J1 mains power Access wiring through strain relief 115VAC T bushing fitted Connect to drive unit wiring to terminal J6 Access wiring through strain relief bushing fitted Mounting Holes Pendant 4 Circuit breaker Ti Strain Relief Bushing CAUTION Attach the WARNING PLACARD adjacent to the control unit Glidermatic F Commercial Door Operator GLIDEROL GARAG
9. quired door travel is correctly set Glidermatic F Commercial Door Operator GLIDEROL GARAGE DOORS Push Button Operation All control units as standard issue are configured to operate with push button operation featuring momentary contact on open and constant contact on closing as such UP a single press will operate the door in the upward direction DOWN Continuous pressure needs to be applied to the down button to drive the door downward Hold to run Releasing this button will stop the door STOP RESET Pressing this button will STOP the door CAUTION Always disconnect power to unit BEFORE making any setting changes Momentary Contact on Close It is possible to convert the push button operation to Momentary Contact on Close from Constant Contact on Close This will enable a single press of the button to close the door To enable this move jumper on JP4 Latch terminal from OFF to ON When enabling momentary contact closing operation it is essential that a supplementary safety device such as a sensing edge or Photo Electric cell be fitted to prevent injury or entrapment Glidermatic F Commercial Door Operator GLIDEROL GARAGE DOORS Safety Reversing An inherent safety feature of the Glidermatic operator is the overload function This ensures that a closing door will stop and reverse it s motion if an obstruction is encountered CAUTION Always disconnect power
10. tting changes Power to the receiver is supplied from terminals 5 amp 6 of J3 5 is ve 6 is ground Ensure Jumper JP2 is configured to match required voltage of radio control receiver 5 12 or 24VDC Single Output Type Receiver Connect output of receiver to terminal 4 of J3 Open Close Stop Type Receiver Connect terminals Up Down and Stop of Radio Control Receiver to 1 2 amp 3 respectively Ensure the jumper JP4 Latch terminal is set to ON Edge jumper JP3 is set to N O Pcell jumper JP3 is set to N O It is essential that a supplementary safety device such as a Sensing Edge or Photo Electric Cell be fitted when radio control unit is fitted to prevent injury or entrapment Consult the installation instructions supplied by the manufacturer of the radio control unit being installed for further detail including the coding of hand transmitters Glidermatic F Commercial Door Operator GLIDEROL GARAGE DOORS Radio Control Wiring There are several popular Radio control units that may be connected to the Glidermatic control unit The wiring configuration for some of these units is highlighted below EE i bes riULil z sr Linear Kae sk Digi Code Glidermatic F Commercial Door Operator GLIDEROL GARAGE DOORS Automatic Close Function The Glidermatic operator can be configured to automatically close the door after a prescribed period