Engineering Manual (English)
Contents
1. battery low NOTE If there is no communication from the wall module e g because battery was removed the battery state will be set to 1 teached1 Bit 0 but saves room 1 handheld 1 sensor 9 3 nvoRfState os 1 taught value over room 2 handheld 2 sensor 10 teached16 0 no device taught power down room 8 handheld 8 sensor 16 lastRfDevice Byte Contains info on origin of last 0 16 message received by W7070A room 1 handheld 1 sensor 9 room 2 handheld 2 sensor 10 room 8 handheld 8 sensor 16 1SH HB 3 Sharable bindable points can be set up for data sharing either a data source or a destination These points are sent out onto the network at a certain fixed interval heartbeat If there is no RF communication with the wall module the battery state will be set to 1 This may require up to 2 hours Each of these variables exists for rooms 1 through 8 and has a single digit index of 1 8 ENOB 0286GE51 R0106 ZAPP WIRELESS SYSTEM Table A3 continued Output Network Variables associated with the W7070A NV Name Field Name Engineering Units English Default sy HB Comments Metric or States plus Range nvoRfState lastCommand Enum Contains info on last message received by 0 OFFS_HIGHER W7070A OFFS_LOWER OFFS_ZERO OFFS_MIN OFFS_MAX FAN_HIGHER FAN LOWER FAN_AUTO FAN_MAX FAN_OFF OCC_BYP OCC_UNOCC OCC_NUL OCC_OCC LIGHT_MAX LIGHT_MIN LIGHT_
2. may be required see Fig 2 Different connections to the termination module are necessary depending upon whether it is used in a single or double terminated network configuration TERMINATION MODULE 209541B Fig 2 Termination module connection daisy chain network configuration shown NOTE The LonWorks network is insensitive to polarity eliminating installation errors due to miswiring Wire the W7070A s LonWorks communications network using level IV 22 AWG or plenum rated level IV 22 AWG non shielded twisted pair solid conductor wire IMPORTANT Do not bundle wires carrying field device signals or LonWorks communications together with high voltage power supply or relay cables Specifically maintain a min separation of 80 mm between such cables Local wiring codes may take precedence over this recommendation IMPORTANT Try to avoid installing in areas of high electromagnetic noise EMI The LonWorks network is connected to terminals 5 and 7 Terminals 6 and 8 may be used to connect further devices to the same LonWorks network Step 4 Power Supply IMPORTANT Local wiring guidelines e g VDE 0100 may take precedence over recommendations provided in these recommendations All wiring must comply with applicable electrical codes and ordinances Refer to job or manufacturers drawings for details Use a min of 18 AWG 1 0 mm and
3. order for the W7070A to receive information on room temperature you must assign the same unique number to both the RT7070A in a particular room and the T7270A1001 or T7270A1019 located in that same room The W7070A is now ready to receive teach in messages from the room units 3 Teaching In a Room Unit 3a Teaching In an RT7070A On the RT7070A press UP B and OK simultaneously to send the teach message to the W7070A If the teach in was successful the W7070A will display the corresponding texts PRESENT and Ok The appearance of the L symbol indicates that the device which has been taught in is an RT7070A RT7070A taught in teach in successful Fig 7 RT7070A successfully taught in ENOB 0286GE51 R0106 ZAPP WIRELESS SYSTEM 3b Teaching In a T7270A 1001 or T7270A1019 In order to perform the teach in procedure for a T7270A1001 or T7270A1019 you must first open its housing revealing the battery compartment and in the top right corner transmission button If you then insert the battery or press the transmission button the teach message will be sent to the W7070A If the teach in was successful the W7070A will display the corresponding texts PRESENT and Ok The appearance of the 7 symbol indicates that the device which has been taught in is a T7270A1001 or T7270A1019 T7270A taught in teach in successful Fig 8 T7270A successfully taught in The appearance also of both the L s
4. other devices and the building structure it is not possible to exactly define the wireless transmission range General Guideline The max distance between the W7070A and ZAPP room units should be less than 30 meters and there should be no more than two walls between the W7070A and ZAPP room units RF transmission between the W7070A and ZAPP room units may be disrupted by interference from metal objects in the building metal cabinets doors mirrors concrete ceilings iron grills aluminum laminated plates other radio transmitters e g wireless phones and power switching devices Establish and check radio communication of the ZAPP room units with regards to interference e g Use LonMaker or EXCELON in conjunction with nvoRfState LastCommand to verify a successful transmission from the ZAPP room units to the W7070A If interference occurs select an alternative location for installation Step 3 LonWorks Communications The W7070A utilizes a free topology transceiver FTT10A Link Power compatible LonWorks network that allows daisy chain loop and star network configurations or any combination thereof see also Excel 50 500 LONWoRKS Mechanisms Interface Description Product Literature No ENOB 0270GE51 for a complete description of possible layouts and wiring details including max lengths ENOB 0286GE51 R0106 Depending upon the LonWorks network configuration used one or two termination modules
5. 6 ZAPP WIRELESS SYSTEM The fixed values of the variables are described in the ZAPP Handheld User Manual Product Literature No EN2B 0205GE51 Table A3 Output Network Variables associated with the W7070A NV Name Field Name Engineering Units English Default SH HB Comments Metric or States plus Range nvoOccManCmd SNVT_occupancy OxFF no xX Enables OCCUPANCY functionality 0 OC_OCCUPIED override 1 OC_UNOCCUPIED 2 OC_BYPASS OxFF OCC_NUL nvoSetPtOffset SNVT_temp_p 0 x x Enables SETPOINT OFFSET 5 5 K due to nciRmConfig functionality value SNVT_switch value 0 100 O x Manual user override of fanspeed state SNVT_switch state NUL x nvoFanSpeedCmd 0 OFF 1 ON 255 NUL nvoSbIndManPos SNVT_setting SET_NUL x Enables SUNBLIND functionality 3 SET_UP no action 2 SET_DOWN 4 SET_STOP 255 SET_NUL SNVT_switch value 0 100 0 x Enables LIGHT functionality SNVT_switch state NUL x Enables LIGHT functionality nvoLampManPos 0 OFF 1 ON 255 NUL value SNVT_switch value 0 100 0 x Enables LIGHT functionality state SNVT_switch state NUL Xx Enables LIGHT functionality nvoFreeUse 0 OFF 1 ON 255 NUL nvoSpaceTemp SNVT_temp_p 0 40 C invalid x x Contains info on room temperature of taught in wall module BatteryState1 Bit 0 ok Battery condition for handheld 1 8 wae 0 battery ok or sensor 9 16 in the rooms BatteryState16 1
6. 70A will then recognize commands it receives from them Teaching in can be done as described in the following sections or by using the plug in NOTE When using the plug in to teach in the room units it is necessary that you stop teaching in a given room unit before starting to teach in the next room unit This is because the W7070A will remain in the teach in mode for 5 minutes and you may accidentally teach in the device again if you do not wait sufficiently long before teaching in the next device 1 Enabling the Teach In Mode Press the button on the W7070A for at least two seconds TEACH and 1 is displayed thus indicating that the W7070A is now in the teach in mode for room 1 room number Fig 5 W7070A in teach in mode NOTE If you enter no input within 3 minutes the W7070A will revert back to the normal mode NOTE W7070A s manufactured before date code 0438 have factory settings which do not support allocation of the T7270B1009 In order to nonetheless allocate a T7270B1009 you must press the teach in button for 20 seconds during power up This command deletes all previous teach in information 2 Selecting a Unique Number You must now assign a unique number 1 through 8 to the given room unit by pressing the button on the W7070A as many times necessary unique number Fig 6 Assigning unique number Since the RT7070A Wireless Handheld is not equipped with a temperature sensor in
7. Honeywell ZAPP WIRELESS SYSTEM HONEYWELL EXCEL 5000 OPEN SYSTEM SYSTEM ENGINEERING INTRODUCTION Organization of this Manual NOTE Since the RT7070A Wireless Handheld is not This manual is organized to guide you through the equipped with a temperature sensor wie w070 tact from stari to finish or adding to r will receive no temperature information from a room eA a o aa ie pa ti o Ti a ti b id in which an RT7070A is not supported by an PAANAN SASN SYSE ee eee additional T7270A1001 or T7270A1019 located in Application Steps provide the information needed to make a hee that same room accurate ordering decisions These steps are guidelines intended to aid understanding of the product options bus arrangement choices configuration options and the wireless The W7070A receives commands from ZAPP room units ZAPP system role in the overall EXCEL 5000 System handhelds or wall modules and then forwards them to the architecture controllers e g the Excel 10 or Excel 12 connected within the same LONWorkS network see Fig 1 Description of Devices The ZAPP system consists of the W7070A ZAPP Wireless Receiver and up to eight rooms each containing a ZAPP room unit There are four types of ZAPP room units IMPORTANT The W7070A may be used only in countries where use of ISM 433 MHz band is permitted the RT7070A Wireless Handheld The W7070A currently hasa radio frequency registration in most European countri
8. START_DIM LIGHT_STOP_DIM SBL_UP SBL_DOWN SBL_STOP OFFICE_STYLE_1 OFFICE_STYLE 2 FREE_MAX FREE_MIN FREE START_DIM 26 FREE_STOP_DIM 27 DIRECT_SETPT 28 ROOM_TEMP 255 CMD_NUL ARONADOODNDDAWNAOPONDUIRWN Po Pp PM PO PP AH A Aa aaa saa nvoRfState TeachActive SNVT_count 0 16 Contains info on the number of the room unit currently in the teach in mode 0 no teach in process room 1 handheld 1 sensor 9 room 2 handheld 2 sensor 10 room 8 handheld 8 sensor 16 major W7070A neuron application software version nroSwVersion minor bug object_id 0 NODE_OBJECT 1 ROOM1 2 ROOM2 3 ROOM3 nvoStatus ea 8 ROOM8 invalid_id 0 VALID_ID 1 INVALID_ID disabled 0 ENABLED 1 DISABLED 1SH Sharable bindable points can be set up for data sharing either a data source or a destination HB These points are sent out onto the network at a certain fixed interval heartbeat 9 ENOB 0286GE51 R0106 ZAPP WIRELESS SYSTEM ACCESSORIES AGENCY LISTINGS ABBREVIATIONS AND LITERATURE Accessories Wall Holder for Handhelds The RT 70 HRD20 Wall includes 10 wall holders for the RT7070A LonWorks Termination One or two LONWoRKS terminations are required depending on the given LonWorks bus layout Two different LONWoRKS terminations are available e _LONWoRKS termination module order no 209541B e LoNWorkS connection term
9. T_time_sec 1 240s 60 maximum movement time fur sunblind NOTE The sunblind runtime must be the same in the T7270B1009 the W7070A and in the connected controller e g an XL12 lamp_runtime SNVT_time_sec 1 60s 10 button 5 bright max time for brightening lamp_start 1 100 button 5 bright Start dimming at 100 or at O last level last light level lamp_increment SNVT_lev_percent 0 100 100 button 5 bright Step height for dimming free_runtime SNVT_time_sec 1 60s 10 button 6 free max time for brightening free_start 1 100 0 button 6 free Start dimming at 100 or at O last level last light level free_increment SNVT_lev_percent 0 100 100 button 6 free Step height for dimming nciSndHrtBt SNVT_time_sec 60 Length of timeout after which the W7070A sends nvoSetptOffset and nvoSpaceTemp out onto the network 1SH Sharable bindable points can be set up for data sharing either a data source or a destination HB These points are sent out onto the network at a certain fixed interval heartbeat ENOB 0286GE51 R0106 ZAPP WIRELESS SYSTEM Table A2 Input Network Variables associated with the W7070A NV Name Field Name Engineering Units Digital Default SH HB Comments English Metric or State States plus Range Value SNVT_Count FFFFh W7070A supports up to eight rooms Each 1 16 room is split into two functional areas the 0 FFFF handheld area 1 8 and the sensor wall module a
10. a max of 14 AWG 2 5 mm for all power wiring The power supply 24 Vac 420 50 or 60 Hz is connected to terminals 1 and 3 Terminals 2 and 4 may be used to con nect further devices to the same 24 Vac power supply ZAPP WIRELESS SYSTEM ZAPP RECEIVER 24 VAC 24 VAC 24 VAC 24 VAC LonWorks LonWorks lt LonWorks 120 240 VAC 24 VAC COM LonWorks NETWORK IN LonWorks NETWORK OUT lt LonWorks Fig 3 W7070A terminal assignments Step 5 Configuring the W7070A The W7070A is configured using a plug in which may be used with CARE or any other LNS based tool such as LonMaker for Windows If the factory pre configuration already fits your needs configuration is not necessary see Appendix NOTE If communication between the W7070A s neuron processor and its co processor is interrupted the W7070A will display an error message see Fig 4 This will occur e g when an unconfigured W7070A is powered up To resume normal operation set the W7070A to configured online error message Fig 4 Error message no LonWorks communication Step 6 Teach In Procedure Teach in is a procedure required to allocate ZAPP room units located in the various different rooms to the W7070A Up to eight rooms each containing a room unit can be allocated to a single W7070A After successful completion of the teach in procedure for each individual room unit the W70
11. es A B CH D e the T7270A1001 Analog Wall Module with temperature DK E F FIN IT LUX N NL and UK sensor and setpoint e the T7270A1019 Analog Wall Module with temperature sensor and e the T7270B1009 LCD Wall Module for HVAC light and sunblind applications sf A wo 1h nn asema ati A Widdi ANA TTT J ZIM s camer T7270B1009 ES MINNN Y hardwired l m actuators e A Excel 12 Lo La onWorks 75 T7270A1001 T7270A1019 W7070A na wireless communication RT7070A Fig 1 System overview U S Registered Trademark Copyright 2006 Honeywell Inc C fa LONMARK All Rights Reserved ENOB 0286GE51 R0106 ZAPP WIRELESS SYSTEM APPLICATION STEPS Overview Steps one through seven describe the engineering These steps are guidelines intended to aid understanding of the product options bus arrangement choices configuration options and ZAPP s role in the overall EXCEL 5000 System architecture step description System Planning Range of RF Transmission LonWorks Communication Power Supply Configuring the W7070A O o RR op Teach in Step 1 System Planning Plan the use of ZAPP according to the required functionality and the sensor or actuator usage When planning the system layout consider potential expan sion possibilities to allow for future growth Step 2 Range of RF Transmission Because of interference from
12. ination module can be mounted on DIN rails and in fuse boxes order no XAL Term Agency Listings Honeywell XAL Term 1 5 shield shield 0 6 plug in Beje terminstion Jumper ETT LPT Bus ETT LPT Free Park Position removable Screw type 3 pole terminal block Fig 17 Lonworks connection and termination module Table 1 provides information on agency listings for wireless ZAPP system products Table 1 Agency listings Devices Agency Comments General Immunity per European Consortium standards EN50081 1 CISPR 22 Class B and EN 50082 1 1992 based on Residential Commercial and Light Industrial EN 61000 4 2 IEC 1000 4 2 IEC 801 2 Electromagnetic Discharge W7070A CE EN 50140 EN 50204 IEC 1000 4 3 IEC 801 3 Radiated Electromagnetic Field T7270A EN 61000 4 4 l IEC 1000 4 4 IEC 801 4 Electrical Fast Transient Burst T7270B Radiated Emissions and Conducted Emissions EN 55022 1987 Class B CISPR 22 1985 FCC Complies with requirements in FCC Part 15 rules for a Class B computing device Honeywell Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies S rl Ecublens Route du Bois 37 Switzerland by its Authorized Representative Automation and Control Solutions Honeywell GmbH B blinger Stra e 17 D 71101 Sch naich Germany Phone 49 7031 637 01 Fax 49 7031 637 493 http e
13. lows 1 Press the button on the W7070A for 5 seconds to enter the teach in mode 2 Select the room you want to de teach by pressing the button on the W7070A as often as necessary until the unique number of the given room unit appears in the display 3 Press the button on the W7070A continuously for at least five seconds until the word PRESENT in the display disappears Checking the Status of a Room Unit It is possible to check the status i e taught in status battery level of individual room units This is done as follows 1 Press the button on the W7070A The status including all relevant information of the first room will appear 2 To check the status of the next room press the button on the W7070A see also the examples in Fig 12 through Fig 14 Fig 12 T7270A and RT7070A taught in for room 1 battery level OK PRESENT Fig 14 T7270A taught in for room 3 battery level OK ZAPP WIRELESS SYSTEM APPENDIX W7070A NETWORK VARIABLES Node Object LonMark Object type 0 nviRequest t e nvoStatus SNVT_obj_request etwor SNVT_obj_status Variables NviTeachActivate T nvoRFState SNVT_count etwor Non_SNVT Variables nciRmConfig config Non_SNVT Configuration NciSndHrBt Parameter config SNVT_time_sec value file Fig 15 Node Object nvoSetptOffset1 SNVT_temp_p nvoFanSpeedCmd1 SNVT_switch nvoOccManCmd1 SNVT_occupancy nvoLa
14. mpManPos1 SNVT_switch nvoSbindManPos1 SNVT_Setting nvoFreeUse1 SNVT_switch nvoSpaceTemp1 SNVT_temp_p es nvoSetptOffset8 SNVT_temp_p nvoFanSpeedCmd8 SNVT_switch nvoOccManCmd8 SNVT_occupancy nvoLampManPos8 SNVT_switch nvoSbindManPos8 SNVT_Setting nvoFreeUse8 SNVT_switch nvoSpace Temp8 SNVT_temp_p XY Fig 16 Network Variables per room ENOB 0286GE51 R0106 ZAPP WIRELESS SYSTEM The following tables list all network variables associated with the W7070A Table A1 Configuration Network Variables associated with the W7070A NV Name Field Name Engineering Units English Default SH HB Comments Metric or States plus Range low_setpt SNVT_temp_p 0 5 Kelvin 5 lower temperature setpoint offset limit high_setpt SNVT_temp_p 0 5 Kelvin 5 upper temperature setpoint offset limit fanstages enum 0 3 THREE_ number of possible fanspeeds 0 no fan 0 NO FAN SPEED 1 3 1 3 speeds plus AUTO OFF 1 ONE_SPEED 2 TWO_SPEED 3 THREE_SPEED bypass Bit ALLOWED Allows the OCCUPANCY functionality to be 0 NOT_ALLOWED invoked via handheld 1 ALLOWED UNOCC Bit ALLOWED Enables manually changing occupancy state 0 NOT_ALLOWED to unoccupied 1 ALLOWED OCC Bit ALLOWED Enables manually changing occupancy state nciRmConfig 0 NOT_ALLOWED to occupied 1 ALLOWED sbInd_runtime SNV
15. rea 9 16 NOTE If the application supports additional NVs e g as may be the case with customized solutions the actual number of supported rooms may in fact be lower For ease of understanding in this docu ment the term sensor is used for 9 16 The assignment is as follows room 1 handheld 1 sensor 9 room 2 handheld 2 sensor 10 nviTeachActivate room 8 handheld 8 sensor 16 To teach in the sensor in room 3 you must set nviTeachActivate 11 nviTeachActive 0 or FFFFh no activity stop process possible range 1 16 FFFFh The visual LCD behavior of the W7070A is equal to teach in without tools The result of teach in can be read out of nvoRfState teached SNVT_obj_request This input variable belongs to the Node 0 NODE_OBJECT Object and provides the mechanism to object id 1 ROOM1 request a particular mode for a particular ject 2 ROOM2 object within a node 8 ROOM8 nviRequest object_request_t See above Commanding any modes other RQ_NORMAL 0 than the ones listed will result in an object_request RQ_UPDATE_STATUS 2 invalid_request when reading nvoStatus RQ_RESET 17 Occupancy state is reset to unoccupied and nvoSetPtOffset is set to 0 1SH Sharable bindable points can be set up for data sharing either a data source or a destination HB These points are sent out onto the network at a certain fixed interval heartbeat 7 ENOB 0286GE51 R010
16. urope hbc honeywell com Subject to change without notice Printed in Germany EN1B 0286GE51 R0106 DIN EN ISO 9001 14001
17. ymbol and the 7 symbol indicates that an RT7070A and a T7270A to both of which the same unique number has been assigned have been taught in to the same room T7270A taught in f RT7070A teach in taught in successful Fig 9 T7270A and RT7070A successfully taught in 3c Teaching In a T7270B 1009 In order to perform the teach in procedure for a T7270B1009 on the RT7070A press F and DOWN simultaneously for 5 seconds thus starting the display test and sending the teach message to the W7070A or simply power up the T7270B1009 If the teach in was successful the W7070A will display the corresponding texts PRESENT and Ok The appearance of the u symbols indicates that the device which has been taught in is a T7270B which incorporates HVAC light and sunblind functionality T7270B taught in teach in successful Fig 10 T7270B successfully taught in 4 Completion of the Teach In Process After successful completion of the teach in procedure for each individual ZAPP room unit the W7070A will then recognize commands it receives from them Further a symbol ENOB 0286GE51 R0106 for incoming commands together with the room number and the battery status of the room unit will be displayed incoming battery commands level room number Fig 11 Incoming commands battery status De Teaching a Taught In Room Unit It is possible to de teach revoke a taught in room unit This is done as fol