Micro cantilever 取り扱い説明書

image

Contents

1. Adhesive stick 6e Tip shape of Tetrahedral tip As can be seen in the left illustration a tetrahedral tip is located at the exact end of the cantilever The finite tip shape will determine the Scan line profile as in the illustrations below The tip profile is symmetric with a half tip angle of 18 degrees macroscopically see left below The side tip profile is asymmetric with a tip angle of 35 degrees Then the cantilever chip is attached to a chip holder in your AFM with an angle about 10 degrees the asymmetry is improved see right below 10 deg 18 deg scan line profile A Sean line profile along B B Tip shape and scan line profile Scan line profile along A A The apex of the tetrahedral tip becomes sharper due to an oxide sharpening process The tip angle around a few hundreds nano meter down from the apex is about 15 to 25 i 15 25 deg 15 25 deg degrees see below Front view Side view Sharpening effect around tip apex When you set your samples to your instrument please consider the unique shape of the tetrahedral tip that is good symmetry when viewing from its front side and choose the direction of the sample When measuring long grooves you can get an idea of what angle of the cut will be quickly by aligning the cantilever along the grooves and scanning across at right angles against grooves see below 6 Information Please contact following if y
2. Micro cantileverf user s manual Thank you for purchasing OLYMPUS Micro cantilever Please read this manual carefully before use lt Explanation of the each part of the products gt Cantilever chips in a plastic case are included in the envelope with manual and spec sheet Manual and Specification sheet Plastic pack translucent blue Label Inside Plastic case Cantilever chips are in the case Cantilever chips are contained in the plastic case Tac carrier Case Tac carrier Adhesive sheet Cantilever chips Upside g ae Down side Ky Cantilevers are tip side up Case Label y as viewed in the case Tape Case closed Case open Magnified illust OMCL AC240TS C2 Lot Number Laia p Kesonant frequency il Ss a Pal p a a 70_ KH st Spring constant 2 Nim ae A Dip yea olympus cop probe Pal call OLYMPUS pac Inspection stamp One cantilever elongates from the side of round shoulders of the chip ae OLYMPUS Please obey the following to the OLYMPUS micro cantilevers Warning Use protective eye glasses when handling to avoid damage to the eyes from breakage of the cantilever chips A Caution Please handle our cantilevers carefully because they are fragile N Caution Do not drop or shake the cantilever case Even when the cantilever chips are contained in the cantilever case the cantilevers may break if the case is handled roughly or ja
3. age of this manual C aution Table of contents l l Page Please handle our cantilevers carefully because they are fragile 1 e A Caution 2 e 5e Te al fe It is recommended that precautions be taken to prevent damage to the cantilever tips from electrostatic discharge 1 It is recommended that the cantilever case be opened in a clean environment like a clean bench in order to avoid the cantilever being contaminated Handling under an ionizer is recommended 2 Avoid wearing clothes like woolen sweaters fleece etc that give off the static electricity when Specification m vn handling the cantilever cases and chips Use of an anti electrostatic mat and wrist band is preferable 8e 4e 3 In opening the case put the plastic case label side down on a desk The cantilevers are tip side up as viewed in the case 4 Open the case Picking up the cantilever chip from the case Caution Avoid any contact with the cantilevers when you pull up the cantilever tip from the case A Caution Cantilever chips should always be placed tip side up 1 Press down gently on the part between the center and one third of the chip along the center line with the adhesive stick see left below Cantilever 2 Do not press the chip too much or the chip might be buried in the Gel sheet and the cantilever must break et VND CHIP 3 Pull up the tick carefully then the adhered chip is pic
4. ked up together see below how up one third of the chip Press here Center line of the chip Adhesive stick Adhesive stick Cantilever and tip A Cantilever chip h Gel sheet Note Some of the both side adhesive tapes have not enough adhesive to pick up the chip from the Gel sheet Then use the tweezers for this procedure 5e Attachine the cantilever chips to your instrument 1 Please read the instruction manual of your scanning probe microscope before this operation To attach the cantilever chip to the holder in your scanning probe microscope 2 Place the chip on the adhesive stick gently against the prescribed part in your chip holder see left below 3 Press the center of the chip with sharp pointed tweezers and pull apart the stick from the chip see right below 4 Lock the chip into the chip holder in accordance with the manner described in the manual of your SPM Most of the chip holders in AFMs use a leaf spring or a wire for pressing the chip to the holder It is recommended that the chip be pressed with those at the center of the chip to achieve a good mechanical coupling between the chip and the holder Adhesive stick Tweezers Cantilever chip Cantilever and tip a o a Chip holder Chip holder Note To avoid contact with the cantilever the tweezers should not access to the chip from cantilever side Put the tweezers on the chip like following illustration Tweezers
5. on Stereo microscope l l l a 1 1 1 1 aA a a np TA typically 7 a oes f f 3 Wind both side adhesive tape around the top of the thin stick to prepare an adhesive stick for A sharpened tetrahedral tip of single crystal silicon is employed for high resolution e a eee ae lt ideal f Her cae a picking up the chips from Tac carrier case rans Be eet is oe j as Beate ua ais a ean ap 4 Cut the top of the wound adhesive tape with scissors to make the top of the adhesive flat addition to the geometrical dimensions of the tip the tip is further sharpened with our exclusive sharpening process Both side wea adhesive tape V Jo F OON The wav to make an adhesive stick Adhesive part Cut off here with Scissors Symmetric tip The tetrahedral tip is thin with the macroscopic tip angle of 35 degrees viewing from both its front and side Tip shows good symmetry in viewing along the cantilever axis see Chapter 5 Symmetric shape tip results AFM images less distortion which reduce misinterpret of the data Reflex coating cantilever Aluminum is coated onto the back side of the cantilevers for optical deflection sensing Good S N signal can be expected in the optical sensor circuit Compatible chip The thickness of the chip substrate is 0 3 mm Open the case This type of the chip can be attached to most of AFM instruments See the specification sheet of OLYMPUS Micro cantilevers at the last p
6. ou have any question on this user s manual OLYMPUS CORPORATION Microtechnology R amp D Division 2 3 Kuboyama cho Hachioji shi Tokyo 192 8512 Japan email probe olympus co jp Please access to the web page of OLYMPUS micro cantilevers http www olympus co jp probe Ver 2 0 June 22 2009 OLYMPUS CORPORATION 8e
7. rred A Caution It is recommended that precautions be taken to prevent damage to the cantilever tips from electrostatic discharge A Caution When discarding please obey the laws and regulations in your country and or your company These cantilever are made from silicon and aluminum Special feature of OLYMPUS Micro cantilever OMCL AC2 AOTS C2 1 Please prepare the followings before using OLYMPUS cantilevers 2 To gain a better understanding of how cantilevers and chips are connected cantilevers should AC mode cantilever This type of micro cantilever is for AC dynamic mode AFM operation be inspected under the microscope High mechanical Q factor of the cantilevers allows you high sensitivity measurement to probe your sample surface gently 1 Work environment Clean bench Use of an electrical charge neutralizer of ionizer is recommended 2 For hazard avoidance Protective eye glasses Pre separated chip Each cantilever chips is isolated in the case The chips can be attached to the AFM instrument as soon as the case is open f 3 For cantilever treatment Tweezers Thin bamboo stick Tip View The tip is located on the very end of the cantilever Use of anti electrostatic discharge mat and a wrist band is This feature allows you to set the tip over a point of interest on the sample easily and recommended precisely if you use an AFM combined with an optical microscope 4 For inspecti